        Keurig B150 Coffeemaker User Manual
         Contents
1.         KEURIG    B150 Series Commercial Brewer  Direct Plumb Kit    Welcome Keurig Authorized Dealer        This manual provides   e Installation of the Direct Plumb Kit  DPK  that allows you to connect your  customer   s B150 brewer to municipal or independently pumped water supply   e Maintenance Mode diagnostics that will provide you with system information and  tools so that you can fully diagnose any problems at the customer   s site   e Instructions on how to descale the brewer in the event of problems associated  with hard water     P N 60 201142 000 Rev A 10 09    B150 Direct Plumb Unit Installation Instructions    The B150 brewer is designed to be easily transformed from the as purchased  Pour Over  configuration to a plumbed unit  Reconfiguration is designed to be easily and quickly  accomplished by a technician using only a  2 Phillips screw driver     It is advised that prior to beginning installation that all water be drained from the system  using the drain tubes located at rear of brewer  see Page 8 for Draining Instructions   The  brewer MUST also be disconnected from AC power supply during DPK installation     1  Disconnect the brewer from AC power and drain the brewer   s Hot Water Tank as  detailed in instructions shown on Page 8    2  Remove the Cold Water Tank  CWT  that came with brewer  FIGURE 1   3  You will now need to remove two covers to properly connect the DPK to the  B150 Brewer  Turning the drained brewer on its left side  locate and remove the
2.   2 screws located below that Cold Water Tank  For easy identification  the screws  are located within indented surfaces on the Base Plate  FIGURE 2    _             FIGURE 1  4  Remove and reserve the screws  The Connection Access Plate can now be  removed  FIGURES 3  amp  4    i 3               FIGURE 3 FIGURE 4    5  On the side of the brewer locate the Connector Cover  Remove and reserve the  screw  Remove the Connector Cover and expose DPK Interface Connector   FIGURES 5  amp  6       FIGURE 5   FIGURE 6  6  Make the electrical connection between the DPK CWT and the brewer body  The  Connector Cover has an alternate position that allows for cable exit and    reattachment to the Brewer Body  FIGURES 7  amp  8             FIGURE7 FIGURE 8  7  Install DPK and secure to Brewer Base using the 2 screws that were previously  used for the Connection Access Plate  FIGURE 9           FIGURE 9  8  The B150 Direct Plumbed Unit is now ready to be connected to AC Power and    filtered water supply in accordance with local Building Code rules and  regulations     Filter Requirements    The Keurig B150 brewer system  when used with Direct Plumb accessory   requires the use of a water filtration system to optimize the coffee flavor and  brewer reliability  Two mounting holes with screws have been provided on the  back of the brewer for this purpose     Keurig requires the use of an external water filter such as the Omnipure  KQS8A to maintain warranty     A filter kit  part number 5025  
3. Access Panel removed    Purpose    Maintenance    This section describes the Maintenance Mode and key sequences for entry into this mode  for the B150 Brewer     Maintenance Mode Layout    Entry  From STANDBY  press all 4 corners of the touchscreen  Upper Left Right and  Lower Left Right in any order  within 3 seconds      releasing after each touch    l     Screen    Screen 2      Life      10  Screen 10    11     Screen 3    Screen 4    Screen 5  years      Screen 6    Screen 7  Screen 8    Screen 9    NOTE   Progress from screen to screen using the flashing Brew Button           Software Version            Total Brew Count              Postfill Timeouts             Add2 Timeouts             Add4 Timeouts             Add6 Timeouts                Add8 Timeouts             Dispense Timeouts             Over Pressure Events        Top of Tank Events            Run Hours              4 oz Brew Count            6 oz Brew Count            8 oz Brew Count            10 oz Brew Count            12 oz Brew Count       Brew Button   Cont          Buttons control Turning Pump On Off     Brew Button   Cont          Brew Pump        Vent Valves        Buttons control Opening Closing the Valve      e g      v8 25       Max   999 999  25 x     Max   65535    Max   65535    Max   65535    Max   65535    Max   65535    Max   65535    Max   65535    Max   65535    Max   999 999  114     Max   65535    Max   65535    Max   65535    Max   65535    Max   65535      Buttons control Brew Pump On 
4. Off  amp  Opening Closing the    Valve       Touchscreen Calibration        Press Brew button to exit OR touch display to start calibration       IF Cal Passes  exit  If it fails  give another opportunity to try        Exit back to the Standby State    
5. ee times  using 40 ounces    fresh water per fill  Replace Drain Tube Plugs and Access panel    Reconnect or resume city water supply and power up the brewer    Once the brewer is filled and hot  conduct large volume    Water Only    brews   with no K cup potion pack in place  until all remnants of the descale solution are  not longer evident discarding all liquids into the sink  We suggest using the  largest brew size to speed the process  Remember to open and close the brew  handle between each cycle so the blue Brew lights will flash    Place the brewer back into service     You may need to perform additional rinse cycles if you notice any residual taste     Draining Procedure for Hot Water Tank and DPK CWT    This procedure is to be performed prior to transportation of unit and when converting  brewer between Pour Over usage and Direct Plumb usage     NOTICE  THIS PROCEDURE MAY RESULT IN THE RELEASE OF    WATER AT TEMPERATURES HOT ENOUGH TO RESULT IN  BURNS  DRAINING PROCEDURE SHOULD ONLY BE  PERFORMED BY TRAINED SERVICE PERSONNEL        1  Disconnect the brewer from AC power and  if applicable  disconnect the Direct  Plumb Unit from water supply    2  On rear of brewer locate Access Panel and remove securing screw    3  Lower the appropriate tube  remove Plug and drain into appropriate sized  container  NOTE  Hot Water Tank contains   31 oz of water  Cold Water Tank  contains   35 oz of water    4  Replace Plugs and Access Panel        4   rk      ae    Drain Tubes with 
6. er  Reservoir will be clearly evident as shown below     Pour  Descaling  Solution  here       6  Reconnect the brewer to AC Power Supply   7  Proceed with descaling procedure as defined below     De Scaling Procedure    Preparation    Prepare at least 40 ounces of a commercial citric acid descale solution  You will  also need a large ceramic mug  a paper cup is not suitable for this procedure  and access  to a sink for discarding hot liquid     FILL AND CLEAN   1  Pour 40 ounces of descale solution into the Cold Water Tank through the Access  Port shown above and turn on the brewer     the brewer will automatically fill and  begin heating    2  When the brewer display shows    Ready To Brew    place the ceramic mug on the  drip tray  select the largest brew volume  and press the Brew button   NOTE  Do not use a K Cup portion pack   3  Once the solution begins to exit the brewer  lift the Brew Head Handle just   enough to halt the brew process and let the brewer sit for 40 minutes in this state     9       At the end of the 40 minutes  lower the handle and the brewer should complete    the brew  do not be concerned if the brewer does not complete the brew   Pour   the dispensed liquid into the sink    Shut down the brewer  disconnect it from AC power  and drain both  Hot and   Cold  water tanks using the drain tubes located in the back panel of the brewer   CAUTION  Hot water will be exiting from the Hot Water Tank      Manually fill the Cold Water and allow to drain tank thr
7. is available from Keurig  This kit contains a  Omnipure KQ8A filter  filter head  and mounting bracket     NOTE  The KQ8A Filter assembly comes with 1 4 FPT ports for both inlet and  outlet and the plumbed water inlet to the brewer is 3 4 Male Garden Hose Thread  1 4 OD LLDPE  Linear Low Density Polyethylene  tubing is recommended  NSF  compliant  between the filter assembly and the brewer  NSF compliant fittings are  recommended such as High Density Polypropylene Type     NOTE  NO PLUMBING CONNECTORS ARE PROVIDED WITH THIS  KIT     All KQ8A filter cartridges must have a minimum of four gallons of water  run through it after mounting to the brewer and before they are connected to  the brewer   s Inlet Valve at the install location  This procedure will prevent  fine particles of carbon from entering and clogging the water inlet valve     Filter Installation   1  Attach a  4    female garden hose connection to 4    FPT fitting to the Inlet  Valve   2  Mount the filter assembly to the brewer using the screws provided on the back  of the brewer and connect the filter   s Inlet Port to the water supply    3  Flush the filter BEFORE connecting to the Inlet Valve    4  Plug brewer into a dedicated GFCI outlet  If the electric circuit is overloaded  with other appliances  the circuit breaker may trip  If possible  the brewer  should be operating on its own circuit  separate from other appliances  Never  use an extension cord    CAUTION  This brewer is designed to handle local water p
8. ressures from 40 psig up  to 125 psig  Consult a licensed plumber for water pressures in your area  Use  plumbing fittings and tubing specified to withstand 125 psig     IMPORTANT NOTICE  NOTE  FAILURE TO USE A WATER FILTER OR FAILURE TO    USE A WATER FILTER IN THE PRESCRIBED MANNER WILL  INVALIDATE THE BREWER WARRANTY        Descaling Instructions for B150 Brewer with DPK    Minerals in drinking water build up on hot surfaces and can build to a point where fluid  flow is reduced and other normal brewer functions are hindered  When this occurs  the  brewer must be cleared of these deposits to allow normal brewer function     Keurig recommends that the brewer be descaled every 6 months or as needed depending  on use and or local water supply mineral content  Symptoms of scale build up are slow  brewing and or short cups     The following procedure outlines the steps required to prepare the brewer for the addition  of the descaling solution     1  Unplug the brewer from AC Power Supply    2  Disconnect or interrupt external water supply feeding the brewer    3  Drain the Hot Water and Cold Water Tanks using the drain tubes  marked H and  C  located at rear of brewer per the draining procedure as shown below    4  At the rear  left  top of the brewer locate and remove two screws which will allow  removal of the Top Cover and gain access to the internal Water Reservoir               Remove  Screws       5  After removal of Top Plate  the Descaling Solution Access Port in the Wat
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Ewent EW3965  43 年ぶりに返却されたノート(74 吋望遠鏡取説)  TB 9-2330-330-14&P-1  Office des Phabricants d`Univers Singuliers  STEVAL-ISB008V1, USB Li-Ion battery charger and gas gauge  Pentair Water - Apoolco Pool + Wellness  W&T COM-Server - Wiesemann & Theis GmbH  PPalmtop - HP Computer Museum  PVCO-2000 Visiophone 7 pouces couleur sans fil 11 07 2013  Samsung HW-J450 Vartotojo vadovas    Copyright © All rights reserved. 