Home
Hunter Fan 3 Fan User Manual
Contents
1. M For Your Records and n Warranty Assistance we e 3 S For reference also attach your receipt or a copy J j we Nel Nd eI Na a of your receipt to the manual Owner s Guide and Installation Manual SINCE 1886 a Form 45038 01 20090928 2009 Hunter Fan Co Welcome Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and performance for many years This installation and operation manual gives you complete instructions for installing and operating your fan We are proud of our work We appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world Before installing your fan for your records and warranty assistance record information from the carton and Hunter nameplate label located on the top of the fan motor housing Cautions and Warnings e READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING Table Of Contents INSTALLATION SAVE THESE INSTRUCTIONS e Use only Hunter replacement parts e To reduce the risk of personal injury attach the fan directly to the 2 Installing the Hanger Bracket support structure of the building according to these instructions 3 Assembling and Hanging the Fan 6 and use only the hardware supplied To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall s
2. 5 6 Twist canopy trim ring clockwise to secure the canopy Should you need to remove the canopy trim ring follow these steps 1 Twist canopy trim ring counter clockwise until it releases from canopy Step 5 5 8 45038 01 09 28 09 Hunter Fan Company 6 Assembling the Blades Hunter fans use several styles of fan blade irons brackets that hold the blade to the fan 6 1 Your fan may include blade grommets If your fan has grommets Step 6 1 Detail insert them by hand into the holes on the blades 6 2 Attach each blade to a blade iron using three blade assembly screws If you used grommets the blades may appear slightly loose after screws are tightened This is normal 6 3 Remove the blade mounting screws and rubber shipping bumpers from the motor Note Some blade mounting screws are installed in the motor to secure shipping blocks 6 4 For each blade insert one blade mounting screw through the blade iron and attach lightly to the fan Insert the second blade mounting screw then securely tighten both mounting screws Blade Assembly Use with grommet screws Use without grommet Blade Mounting Screw 45038 01 09 28 09 Hunter Fan Company Steps 6 1 6 2 7 Completing Your Installation With a Bowl Light Fixture Your Hunter fan comes with an integrated light fixture assembly A WARNING Use only the light fixture supplied w
3. e Standard screwdriver magnetic tip recommended e Phillips head screwdriver magnetic tip recommended e Wrench or pliers e Ladder height dependent upon installation site Checking Your Fan Parts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor or fan blades If any parts are missing or damaged contact your Hunter dealer or call Hunter Technical Support Department at 888 830 1326 In Canada call 1 866 268 1936 Preparing the Fan Site Before you begin installing the fan follow all the instructions in the pullout sheet called Preparing the Fan Site Proper ceiling fan location and attachment to the building structure are essential for safety reliable operation maximum efficiency and energy savings 4 Installing Multiple Fans If you are installing more than one fan keep the fan blades and blade irons if applicable in sets as they were shipped 45038 01 09 28 09 Hunter Fan Company 2 1 2 2 2 3 2 4 2 Installing the Hanger Bracket Drill two pilot holes into the wood support structure through the outermost holes in the outlet box The pilot holes should be 9 64 _ Isolator in diameter Note Your fan comes with four pre installed neoprene noise Neg isolators ae ee Thread the lead wires from the outlet box down through the hole ee in the middle
4. matching polarity on the battery as indicated by the and symbols in the battery compartment Replace the cover If you are using more than one remote controlled fan in the same area and want to control them separately you must change the dipswitch settings in the remote before you install the battery For instructions on setting the dipswitches read the box on the next page To install the remote cradle on a switch plate remove the two screws holding the switch cover plate Do not remove the cover plate Note If you are installing the remote cradle on a rocker light switch first break off the two tabs by pushing outward Orient the control cradle by lining up the two mounting holes with those on the switch Insert and tighten the screws do not over tighten To install the remote cradle on the wall locate a 2 x 4 wall stud in a convenient location Orient the remote cradle over the 2 x 4 stud Use 1 wood screws in either the inner or outer mounting holes Wall anchors and 6 32 x 1 screws may be used in situations where mounting to a stud is not possible Use the inner mounting holes A CAUTION The remote control device complies with part 15 of the FCC rules Changes or modifications not expressly approved by Hunter Fan Company could void your authority to operate this equipment Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept a
5. of the hanger bracket m f Align the slotted holes in the hanger bracket with the pilot holes pet you drilled in the wood support structure For proper alignment Sei use slotted holes directly across from each other If you are installing the fan on an ANGLED ceiling be sure to orient the hanger bracket as shown in Illustration 2 3 left or right view Note The isolators should be flush against the ceiling Place a flat washer on each of the two 3 screws and pass the screws through the slotted holes in the hanger bracket into the pilot holes you drilled Tighten the screws into the 9 64 pilot holes do not use lubricants g on the screws Do not over tighten Flat Washer Steps 2 2 2 4 Ceiling Peak Ceiling Peak Large Large n 3 Screw LEFT ALAALA a a Step 2 3 Angled Ceiling Only y 5 45038 01 09 28 09 Hunter Fan Company 3 e Assembling and Hanging the Fan A WARNING Fan may fall if not assembled as directed in these installation instructions 3 1 Unbundle the wires from the fan 3 2 To assemble fan to hang down from a flat or angled ceiling 3 3 insert the downrod through the canopy canopy trim ring and upper glass Feed the wires from the fan through the downrod Loosen the set screw on the adapter to install the pipe and ball assembly Note When the pipe and ball assembly is fully installed 2 3 threads on the pipe will still be visibl
6. the screw holes in the upper and lower switch housings Attach the lower switch housing to the upper switch housing with three housing assembly screws lI 45038 01 09 28 09 Hunter Fan Company Steps 7 6 7 7 Lower Switch Plug Connector Housing Plug T Connector Detail Housing Assembly Screw 7 Completing Your Installation With a Bowl Light Fixture Continued Installing the Glass Bowl 7 7 First install B10 candelabra bulbs 40 Watt Maximum into the sockets 7 8 Place the cover plate up against the glass bowl Align the holes in the cover plate and glass bowl 7 9 Screw the finial onto the threaded rod end until tight Note In compliance with US federal energy regulations this ceiling fan contains a device that restricts the light kit toa maximum of 190 Watts Exceeding that limit or the marked limit on this product may result in fire hazard or improper operation Light Bulbs B10 Candelabra Base 40 Watt Maximum Metal Rod Metal Disk Glass Bowl Cover Plate Ss D Finial 12 45038 01 09 28 09 Hunter Fan Company a J Light Bulbs B10 Candelabra Base 40 Watt Maximum 8 1 8 2 8 Assembling the Remote Control and Mounting the Cradle To install the battery remove the back cover of the remote Insert the included 12 volt alkaline battery Type 23A MN 21 or equivalent inside the remote
7. e this is normal Securely retighten the set screw with the provided allen wrench A CAUTION The adapter has a special coating on the threads Do not remove this coating the coating prevents the downrod from unscrewing Once assembled do not remove the downrod A WARNING Do not carry or lift fan by canopy Raise the fan and place the ball into the hanger bracket 3 5 Align the notch on the ball with the indent in the hanger bracket Rotate the fan until you hear the notch pop into place Go to 4 e Wiring the Fan A WARNING Fan may fall if not assembled as directed in these installation instructions 6 Steps 3 2 3 3 Downrod gt Canopy gt Trim Ring Upper _ Glass Steps 3 4 3 5 45038 01 09 28 09 Hunter Fan Company 4 Wiring the Fan All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician Wall switches are not included Select an acceptable general use switch in accordance with national and local electrical codes 4 1 4 2 4 3 4 4 4 5 4 6 4 7 Before attempting installation make sure the power is still off To connect the wires hold the bare metal leads together and place a wire connector over them then twist clockwise until tight For all these connections use the wire connectors pr
8. ease You can install your Hunter fan in one of two ways depending on ceiling height and your preference Standard or Angle mounting The steps in this manual include instructions for the Standard and the Angled Installer s Choice mounting methods Considering Optional Accessories Consider using Hunter s optional accessories including a wall mounted or remote speed control To install and use the accessories follow the instructions included with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans use sturdy 3 4 diameter pipe to assure stability and wobble free performance A CAUTION To reduce the risk of personal injury attach the fan directly to the support structure of the building according to these instructions and use only the hardware supplied 3 45038 01 09 28 09 e Hunter Fan Company l Getting Ready To install a ceiling fan be sure you can do the following e Locate the ceiling joist or other suitable support in ceiling e Drill holes for and install wood screws e Identify and connect electrical wires e Lift 40 pounds If you need help installing the fan your Hunter fan dealer can direct you to a licensed installer or electrician Gathering the Tools You will need the following tools for installing the fan e Electric drill with 9 64 bit
9. eck to see if the blade is cracked If so replace all the blades Problem Excessive wobbling 1 If your fan wobbles when operating use the enclosed balancing kit and instructions to balance the fan 2 Tighten all blade iron screws 3 Turn power off support fan very carefully and check that the hanger ball is properly seated Problem Lights dim when turned on or do not turn on 1 Check to make sure wattage of light bulbs installed match the specifications on the light socket Problem If the light on this fan shuts off suddenly 1 Turn the power to the fan off at the wall switch If you need parts or service assistance please call Wait 30 seconds then resume power to the fan 888 830 1326 In Canada call 1 866 268 1936 or visit us at our Web site at http www hunterfan com Hunter Fan Company 7130 Goodlett Farms Pkwy 400 Memphis Tennessee 38016 16 45038 01 09 28 09 Hunter Fan Company
10. ith this fan model 7 1 To attach the upper switch housing partially install two housing assembly screws into the switch housing mounting plate 7 2 Feed the upper plug connector through the center opening of the housing 7 3 Align the keyhole slots in the housing with the housing assembly screws 7 4 Turn the housing counterclockwise until the housing assembly screws are firmly situated in the narrow end of the keyhole slots Install the remaining screw into the housing Tighten all three screws firmly Steps 7 1 7 2 A CAUTION Make sure the upper switch housing is securely attached to the switch housing mounting plate Failure to properly attach and tighten all three assembly screws could result in the switch housing and light fixture falling Steps 7 1 7 3 Upper Switch Housing 10 45038 01 09 28 09 Hunter Fan Company Housing 7D Place the lower switch housing assembly into the upper switch 7 e Completing Your Installation With a Bowl Light Fixture Continued To attach the lower switch housing connect the upper plug connector from the motor to the lower plug connector in the lower switch housing assembly Note Both plug connectors are polarized and will only fit together one way Make sure the connectors are properly aligned before connecting them Incorrect connection could cause improper operation and damage to the product housing Align
11. ny interference received including interference that may cause undesired operation Note Use with a fan that incorporates an air gap switch normal on off wall switch A WARNING Maximum fan load is 100 Watts maximum lamp is 300 Watts Do not use any speed control with this product 13 Step 8 2 Removed Tabs Step 8 2 Rocker Light Switch 45038 01 09 28 09 Hunter Fan Company 8 Assembling the Remote Control and Mounting the Cradle Continued Setting the Dipswitches You will only have to change the dipswitch settings in the remote if you are using more than one remote controlled fan in the same area and want to control them separately You may want to label your remotes to ensure you do not mix them up 1 At the circuit breaker or fuse box turn the power off for the fan you want to change Do not turn the power off at the circuit breaker for the previously installed fan as you may inadvertently change the dipswitch code settings for it as well Slide the cover off the back of the remote and remove the battery The battery must be removed when changing dipswitch settings Refer to Step 8 1 Change the dipswitch settings so that they are different from the previously installed fan 4 Replace the battery and cover At the circuit breaker or fuse box turn the power back on for the fan whose settings you are changing Within 20 seconds of restoring power p
12. ovided Connect the bare or green ground wire grounding from the ceiling to the green ground wire grounding from the ceiling plate and the green ground wire from the fan Connect the white wire grounded from the ceiling to the white wire grounded from the fan Connect the remaining wires as follows Single Switch Wiring e The black wire ungrounded from the ceiling to the black ungrounded and the black white wire ungrounded from the fan A CAUTION Be sure no bare wire or wire strands are visible after making connections Turn the wire connectors upward and push them carefully back through the ceiling plate into the outlet box Spread the wires apart with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box 7 Wire Connector 45038 01 09 28 09 Hunter Fan Company 5 Installing the Canopy and Canopy Trim Ring 5 1 Partially install two canopy screws about 2 full turns in the Steps 5 1 5 2 Hanger Bracket hanger bracket j 5 2 Raise the canopy over the hanger bracket Align partially installed screws with key slots in canopy 5 3 Twist canopy clockwise to secure 5 4 Install third amp fourth canopy screw in round hole on canopy Securely tighten all four screws Canopy Trim Ri 5 5 Using both hands push the canopy trim ring up to the top of the Canopy y a canopy
13. rush or lint free cloth to prevent scratching A vacuum cleaner brush nozzle can remove heavier dust Remove surface smudges or accumulated dirt and dust using a mild detergent and a slightly dampened cloth You may use an artistic agent but never abrasive cleaning agents as they will damage the finish Clean wood finish blades with a furniture polishing cloth Occasionally apply a light coat of furniture polish for added protection and beauty Clean painted and high gloss blades in the same manner as the fan finish To Change Airflow Direction Press the reversing switch on the remote while the fan is running 15 Downlight Uplight Fan Low Fan High Fan Off Reversing Switch D Steps 9 1 9 2 In warm weather use downward air flow pattern In cold weather use upward air flow pattern 45038 01 09 28 09 Hunter Fan Company 10 Troubleshooting Problem Nothing happens fan does not move 1 Turn power on replace fuse or reset breaker 2 Loosen canopy check all connections according to the wiring the fan section 3 Check the plug connection in the switch housing 4 Push motor reversing switch firmly left or right to ensure that the switch is engaged 5 Pull the pull chain to ensure it is on 6 Remove the shipping bumpers Problem Noisy operation 1 Tighten the blade assembly screws and blade iron armature screws until snug 2 Ch
14. ush the 3 high 2 medium and 1 low buttons in that order on the remote Note The receiver built into the fan has a memory function that retains the last dipswitch code setting The setting will not change in the event of power failure or if the power to the fan is inadvertently shut off 14 45038 01 09 28 09 Hunter Fan Company 9 3 9 4 9 5 9 Operating and Cleaning Your Ceiling Fan To start the fan press the speed button on the remote at the level you desire 3 for high 2 for medium 1 for low To turn off the fan press the off button on the remote You can control the uplight and downlight using separate buttons on the remote To turn the light on or off independently from the fan press the appropriate light button once for gradual off or twice for instant off With the Auto Resume feature the light will come on at the level you used last You can also hold the light button down to use the remote as a dimmer As you hold the button the light level will move throughout its entire range within 16 seconds Release the button at the desired level Ceiling fans work best by blowing air downward counterclockwise blade rotation in warm weather to cool the room with a direct breeze In winter having the fan draw air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft For cleaning finishes use a soft b
15. witch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel 7 Completing Your Installation With a All wiring must be in accordance with national and local electrical Bowl Light Fixture codes and ANSI NFPA 70 If you are unfamiliar with wiring use a 8 Assembling the Remote Control and qualified electrician Mounting the Cradle To reduce the risk of personal injury do not bend the blade attachment system when installing balancing or cleaning the fan Never insert foreign objects between rotating fan blades To reduce the risk of fire electrical shock or motor damage do not use a Solid state speed control with this fan Use only Hunter speed controls 1 e Getting Ready 4 Wiring the Fan 5 Installing the Canopy and Canopy Trim Ring 6 Assembling the Blades 9 e Operating and Cleaning Your Ceiling 2009 Hunter Fan Company 2 45038 01 09 28 09 Hunter Fan Company Installer s Choice and Optional Accessories Support Brace Ceiling Standard Outlet Box Mounting gt Style Standard Mounting hangs from the ceiling by a downrod included Mounting Angle Mounting recommended for a vaulted or angled ceiling Understanding Mounting and Installers Choice Hunter s patented 2 position mounting system provides you maximum installation flexibility and
Download Pdf Manuals
Related Search
Related Contents
MOVIMOT® MM..D Set de modernización para motores CA DRS Le 15 juin 2015 à l`Espace Tête d`Or Lyon - BioDocs-Lyon Stearns YUKATAT B523 User's Manual Organisatorischen und technischen Richtlinien Misuratore magnetico AC/DC 24-Port PoE L2 Managed Fast Ethernet Switch with 2 SFP Dual "取扱説明書" Betriebsanleitung EC-Motor Regelgerät (ECMR) Livret de santé bilingue (anglais/français) © Copyright 2008. Black Box Corporation. All rights reserved. Copyright © All rights reserved.