Home
Chamberlain 459950 Garage Door Opener User Manual
Contents
1. AVERTISSEMENT PLAFOND FINI Une corni re et des fixations peuvent tre requises Se reporter la page 16 Commande de porte murale D tecteur inverseur de s curit L espace entre le plancher de S curit D tecteur Et le bas de la porte ne inverseur de doit tre sup rieur s curit 1 4 de po 6 mm Sans syst me d inversion de s curit en bon tat de marche des personnes particuli rement les petits enfants pourraient tre GRIEVEMENT BLESSEES ou TUEES par une porte de garage qui se ferme e L espace entre le bas de la porte et le plancher NE DOIT PAS d passer 1 4 de po 6 mm sinon le syst me d inversion de s curit pourrait NE PAS fonctionner ad quatement FAUT r parer le plancher ou la porte de garage pour liminer l espace Moteur PORTE FERM E Courroie Chariot Boulon d arr t du chariot Support d delinteau Rail Support de porte Poign e et corde de d clenchement d urgence Biellette Biellette droite courb e Porte de garage PORTE FERM E Chariot Boulon d arr t du chariot Courroie Biellette courb e Support de linteau 00000000000 Poign e et corde de d clenchement d urgence Support Je rore Biellette Porte de droite garage Inventaire de la boite d emballage Votre ouvre porte de garage est emball
2. Safety Reversing Sensor Safety Reversing Sensor OPERATION IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of SEVERE INJURY or DEATH READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS ALWAYS keep remote controls out of reach of children NEVER permit children to operate or play with garage door control push buttons or remote controls ONLY activate garage door when it can be seen clearly it is properly adjusted and there are no obstructions to door travel ALWAYS keep garage door in sight until completely closed NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR NO ONE SHOULD GO UNDER A STOPPED PARTIALLY OPEN DOOR If possible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced door could result in an open door falling rapidly and or unexpectedly causing SEVERE INJURY or DEATH NEVER use emergency release handle unless garage doorway is clear of persons and obstructions NEVER use handle to pull garage door open or closed If rope knot becomes untied you could fall Using Your Garage Door Opener Your Security opener and hand held remote control have been factory set to a matching code which changes with each use randomly accessing over 100 billion new codes Your opener will operate with up to eight SecuritysF remote controls and one Security Keyless Entry System If you purchase a new remote or i
3. V rifier manuellement que la porte est bien quilibr e et qu il n y a pas de probl mes d adh sion e Se reporter la 2 op ration de R glage R glage de sensibilit Apr s fermeture compl te et apr s contact avec le Sol la porte inverse sa course sans raison apparente R p ter le contr le de l inversion de s curit apr s avoir proc d au r glage de la force ou des limites de course Le besoin de proc der des r glages occasionnels des limites de courses et de la force est normal Les variations saisonni res en particulier peuvent alt rer la course de la porte e Se reporter a 1 op ration de R glage R glage Programmation des limites de la course L clairage ne s teint pas quand la porte est ouverte L ouvre porte de garage est quip d un clairage de s curit Cette caract ristique allume la lumi re quand le faisceau lumineux de s curit a t obstru Se reporter la section Fonctionnement Utilisation de commande de la porte murale Fonction d clairage Le moteur de l ouvre porte ronfle bri vement V rifier d abord si le chariot appuie contre le boulon d arr t e D tacher la porte de l ouvre porte en tirant sur la cordon de d verrouillage d urgence Fermer la porte manuellement e D tendre la courroie en tournant crou ext rieur de 4 5 tours Ceci relachera la tension 35 Diagnostic situ sur le moteur een 27 e
4. 0 000 k Learn HESS Bouton Voyant DEL ou oO D tecteur inverseur DEL de s curit diagnostic Cellule mettrice de d tecteur Cellule r ceptrice de d tecteur inverseur du s curit inverseur du s curit T moin lumineux ambre T moin lumineux vert T Mettre le moteur en marche au moyen de la t l commande ou de la commande de porte Le chariot devrait se diriger vers la porte puis s arr ter Si le chariot se r engage avec la porte tirer sur le cordon de D verrouillage d urgence pour le lib rer Chariot 1 1 4 de po 3 18 cm e Resserrer l crou ext rieur jusqu ce que le ressort du chariot ait environ 3 18 cm 1 1 4 po de longueur Sile chariot ne s loigne pas du boulon r p ter les tapes ci dessus Si le statut de batterie DEL n est pas lit convenablement V rifier le connexions de la batterie L alimentation secteur est interrompue et le moteur fonctionne sur alimentation batterie Une DEL fixe avec bip sonore retentissant environ toutes les deux secondes indique que le moteur est en train d activer la porte et qu il fonctionne sure alimentation batterie Une DEL clignotante ave bip sonore toutes les 30 secondes indique que la charge de la batterie est basse Siune DEL rouge reste allum e la restauration de l alimentation secteur et si un bip sonore retentit toues les 30 secondes remplacer la batterie
5. Diagnostic situ sur le moteur Fil de sonnerie vues ohne A lt ee U D U U U U U i JD U i e w L LI Voyant PF DEL d ou DEL diagnostic D tecteur inverseur Bouton de s curit Learn Fiche Diagnostique Cassure du fil des d tecteurs de inverseur de s curit coup ou d connect ou Court circuit du fil des d tecteurs de inverseur de s curit ou inversion des fils noir blanc Court circuit de la commande de porte ou du fil 4 CL AIRS O L ger m salignement des d tecteurs de inverseur de s curit t moin DEL faible ou clignotant Le capteur de r gime du moteur n est pas reconnu Co o OO Des fonctions d autodiagnostic ont t programm es dans votre ouvre porte de garage Le bouton learn ou le voyant DEL de diagnostic mettra un certain nombre d clairs avant de faire une pause pour indiquer la d couverte d un probl me potentiel Consulter la fiche diagnostique ci dessous Sympt me Un des t moins lumineux des d tecteurs de s curit ou les deux n met pas une lumi re constante Inspecter les fils du d tecteur pour d tecter un court circuit agrafe dans le fil corriger la polarit des branchements fils noir blanc invers s les fils cass s ou d branch s remplacer relier si n cessaire D connecter tous les fils
6. Fastener Emergency Release Handle 0000000000 Straight Door Arm Curved Door Arm Figure 1 Clevis Pin 5 16 x1 1 4 Pulley 1 ie 20 cm min Trolley Stop Bolt Lock Washers Nuts 5 16 18 5 16 18x7 8 Door Bracket Figure 2 Pulley ef ne min an Stop Bolt Lock Washers Nuts 5 16 5 16 18 5 16 18x7 8 Cut this end Figure 3 CORRECT INCORRECT Door Curved Door Arm Groove facing out Figure 4 ALL ONE PIECE DOORS 1 Assemble the Door Arm IMPORTANT The groove on the straight door arm MUST face away from the curved door arm Figure 5 Fasten the straight and curved door arm sections together to the longest possible length with a 2 or 3 hole overlap Figure 5 Make sure the garage door is fully closed Connect the straight door arm section to the door bracket with the 5 16 x1 1 4 clevis pin Secure with a ring fastener Pull the emergency release handle disconnecting the outer trolley from the inner trolley by pulling straight down on the emergency release handle and sliding the outer trolley back toward the motor unit Connect the curved door arm section to the trolley using the 5 16 x1 1 4 clevis pin and ring fastener NOTE Adjusting the limits on the following page e The trolley will automatically connect If not review the trolley lockout feature on page 34 e When setting the up limit on the following page the door
7. Lock Feature Designed to prevent operation of the door from hand held remote controls However the door will open and close from the Door Control the Outside Keylock and the Keyless Entry Accessories To activate press and hold the Lock button for 2 seconds To turn off press and hold the Lock button again for 2 seconds The Lock feature will also turn off whenever the learn button on the motor unit panel is activated LOCK Motion Detecting Light Feature The opener light will turn on automatically when a person walks in front of the wall mounted door control This feature works by detecting motion and body heat and may not work in temperatures around 100 F 37 7 C The opener light will come on for 5 minutes then shut off automatically if no additional motion or heat differential is calculated To disable this feature press the Motion Detecting Light On Off button on the left side of the door control We recommend that you disable the motion Gi sensor when using the opener lights as working lights Otherwise they will turn off automatically if you are working beyond the sensor s range Prog Learn Feature The door control is equipped with a Prog LEARN button to assist in learning remote controls to the unit Press the Prog LEARN button once to initiate LEARN mode and the display will show Learn Remote Control Press Learn Button Again to Confirm Press the Prog LEARN butt
8. NOTE Many door reinforcement kits provide for direct attachment of the clevis pin and door arm In this case you Will not need the door bracket proceed to Step 13 SECTIONAL DOORS 1 Center the door bracket on the previously marked vertical centerline used for the header bracket installation Note correct UP placement as stamped inside the bracket Position the top edge of the bracket 2 4 5 10 cm below the top edge of the door OR directly below any structural support across the top of the door Mark drill holes and install as follows depending on your door s construction Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket Drill 3 16 fastening holes Secure the door bracket using the two 1 4 14x5 8 self threading screws Figure 2A Alternately use two 5 16 bolts lock washers and nuts not provided Figure 2B Metal insulated or light weight factory reinforced doors Drill 3 16 fastening holes Secure the door bracket using the self threading screws Figure 3 Wood Doors e Use top and bottom or side to side door bracket holes Drill 5 16 holes through the door and secure bracket with 5 16 x2 carriage bolts lock washers and nuts not provided Figure 4 NOTE The 1 4 14x5 8 self threading screws are not intended for use on wood doors HARDWARE SHOWN ACTUAL SIZE Self Threading Screw 1 4 14x5 8 24 CAUT
9. l extr mit porte ATTENTION Afin de pr venir une BLESSURE occasionn e par un pincement tenir les mains et les doigts loin des joints lors de l assemblage du rail voir illustration Le trou au dessus de cette fen tre est plus gros sur le dessus du rail que sur le dessous Un plus petit trou 3 1 2 po 8 9 cm de distance se trouve pr s du bord du rail Faire tourner le rail arri re de mani re ce qu il ait un trou 3 Placer le moteur sur le mat riel d emballage afin de prot ger le couvercle et reposer l extr mit arri re du rail sur le dessus Pour plus de commodit placer un support similaire pr s du bord oppos environ 4 3 4 po 12 cm depuis l extr mit loign e 1 Retirer la biellette droite les supports de suspension et l axe de chape ins r s l int rieur du rail avant et mettre de c t pour l installation l tape 5 et 12 REMARQUE Pour viter toute BLESSURE lors du d ballage du rail retirer soigneusement le bras rectiligne de la porte ins r l int rieur de la section du rail 2 Aligner les sections de rail sur une surface plate exactement comme illustr et faire glisser les extr mit s effil es dans les plus grosses Les languettes le long du c t se bloqueront en place GARDER LE GROS TROU SUR LE DESSUS RAIL AVANT DESSUS Extr mit effil e T Fen tre Languettes d coup e Trou de Rail avant la poulie VER
10. 20 cm comme illustr aux Figures 1 2 et 3 e Figure 1 Fixer la biellette droite sur le chariot ext rieur l aide d un axe de chape de 5 16 po x 1 po Faire tenir l axe de chape en place avec un anneau d arr t Fixer la biellette courb e au support de la porte de la m me mani re l aide d un axe de chape de 5 16 po x 1 1 4 po IMPORTANT La rainure sur la biellette droite DOIT faire face a l oppose de la biellette courb e Figure 4 e Figure2 Rapprocher les biellettes et aligner les trous Choisir les trous les plus loign s tant donn qu ils permettent aux biellettes d tre plus solides e Figure 3 m thode alternative Siles trous de la biellette courb e sont trop hauts d monter la biellette droite et couper 6 po 15 cm du bout Refixer la biellette droite sur le chariot en orientant la partie coup e vers le bas comme illustr Rapprocher les biellettes Aligner deux paires de trous et raccorder les deux biellettes avec les boulons les rondelles frein et les crous Tirer sur la poign e de d clenchement d urgence en direction de l ouvre porte un angle de 45 de fa on que la bi llette de d gagement du chariot soit horizontale Passer la 1 op ration des r glages page 28 Le chariot se r enclenchera automatiquement lorsque l ouvre porte fonctionnera GRANDEUR R ELLE DES FIXATIONS C crou de 5 16 po 18 sc Anneau d arr t RS Rondelle
11. Appuyer sur l un ou l autre des boutons pour arr ter la porte Tenir le bouton mauve enfonc pour faire descendre la porte la position du BAS souhait e R GLAGES 2 OP RATION R glage de sensibilit Le r glage de sensibilit mesure la force requise pour ouvrir et refermer la porte 1 Appuyez deux fois sur le bouton violet pour que l unit passe en mode de r glage de sensibilit La DEL d indication clignotera alors rapidement 2 Appuyer sur le poste de commande un seul bouton La porte se fermera DOWN 3 Appuyez sur le poste de commande un seul bouton s ouvrira UP 4 Appuyez sur le poste de commande un seul bouton une troisi me fois pour refermer porte DOWN La DEL indicatrice arr tera de clignoter lorsque la force requise pour l op ration aura t m moris e La porte doit se d placer travers un cycle complet vers le haut et vers le bas pour que la force correcte puisse tre m moris e Si l appareil ne peut pas ouvrir et refermer compl tement la porte inspectez la porte pour vous assurer qu elle est bien quilibr e et qu elle ne se coince ou ne colle pas Si la ported ne s arr te pas exactament l o d sir r p tez Programmation des limites de la course AVERTISSEMENT 29 Sans un syst me d inversion de s curit bien install des personnes plus particuli rement les petits enfants pourraient tr
12. curit 11 On DOIT proc der une v rification mensuelle du syst me d inversion de s curit La porte de garage DOIT remonter au contact d un objet d une hauteur de 1 1 2 po 3 8 cm ou un 2 x 4 pos plat sur le sol L incapacit de r gler correctement le dispositif de fermeture peut provoquer DES BLESSURES GRAVES VOIRE MORTELLES TOUJOURS GARDER LA PORTE DE GARAGE BIEN EQUILIBREE se reporter la page 3 Une porte mal quilibr e peut NE PAS remonter au besoin et pourrait provoquer des BLESSURES GRAVES ou LA MORT TOUTES les r parations aux c bles ensembles de ressort et autres ferrures de montage qui sont TOUS sous une tension EXTREME DOIVENT tre confi es un technicien form en syst mes de porte 14 TOUJOURS mettre l ouvre porte de garage hors tension AVANT d effectuer quelque r paration que ce soit ou d enlever des couvercles e CONSERVER CES INSTRUCTIONS 5 Si la fermeture de la porte est g n e la porte remontera Si l obstacle interrompt le faisceau du d tecteur les lumi res de l ouvre porte clignoteront pendant 5 secondes 6 Si l ouverture de la porte est g n e la porte s arr tera 7 Si la porte est compl tement ouverte elle ne se fermera pas tant que le faisceau lumineux sera interrompu Le d tecteur n a aucun effet lors du cycle d ouverture Si le d tecteur n est pas install ou est mal align la porte ne se fermera pas partir d une t l commande main epe
13. lag screws Fasten the opener to the hanging brackets with 5 16 18x7 8 hex bolts lock washers and nuts Check to make sure the rail is centered over the door or in line with the header bracket if the bracket is not centered above the door Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket NOTE DO NOT connect power to opener at this time HARDWARE SHOWN ACTUAL SIZE L Ej ununi Lag Screw 5 16 18x1 7 8 mO Hex Bolt 5 16 18x7 8 Lock Washer 5 16 Nut 5 16 18 4 amp WARNING To avoid possible SERIOUS INJURY from a falling garage door opener fasten it SECURELY to structural supports of the garage Concrete anchors MUST be used if installing ANY brackets into masonry Structural Supports Figure 1 E n Lag Screws 5 16 18x1 7 8 Measure S P Ys A Distance Bolt 5 16 18x7 8 Lock Washer 5 16 Nut 5 16 18 Figure 2 See upport FINISHED CEILIN Bracket 22S SHED G G Not Provided 777 2 2 27 Lag Screws 5 16 18x1 7 8 Bolt 5 16 18x7 8 Lock Washer 5 16 ee Nut 5 16 18 0 TEXTE Lock Washer 5 16 Nut 5 16 18 Figure 3 Lag Screws 5 16 18x1 7 8 Not Provided Bolt 5 16 18x7 8 Bolt 5 16 18x7 8 Lock Washer 5 16 Lock Washer 5 16 Nut 5 16 18 Nut 5 16 18 16 INSTALLATION STEP 6 Install the Door Control Locate door control within sight of doo
14. 8 de po Figure 2B Figure 2A Bord int rieur 5 16 de po x 2 po de la porte ou Non fournis morceau de bois de renfort Ligne du centre vertical de la porte de garage centre vertical UP de la porte v de garage S is autotaraudeuse Figure 4 1 4 de po 14 x 5 8 de po Figure 3 PORTES RIGIDES Pri re de lire et de suivre les avertissements et les instructions de renforcements la page pr c dente Ils s appliquent galement aux portes rigides e Centrer le support de porte sur le dessus de la porte en l alignant avec le support de linteau comme il est illustr Rep rer soit les trous de gauche et de droite soit les trous du haut et du bas Portes m talliques Percer des avant trous de 3 16 pouce puis fixer le support de la porte l aide des vis autotaraudeuses de 1 4 po 14 x 5 8 po fournies Portes en bois Percer des trous de 5 16 po et utiliser des boulons t te bomb e et collet carr de 5 16 po x 2 po des rondelles de blocage et des crous non fournis ou des tire fond de 5 16 po x 1 1 2 po non fournis suivant les besoins particuliers de l installation REMARQUE Le support de porte peut tre pos sur le bord sup rieur de la porte si n cessaire pour une installation particuli re Se reporter au dessin du positionnement facultatif la ligne pointill e Plafond fini Linteau Support 2 x 4 GRANDEUR R ELLE DES FIXATIONS Vis
15. GRAVES ou LA MORT Le support de linteau DOIT tre fix de mani re RIGIDE la solive sur le linteau ou le plafond sinon la porte de garage pourrait NE PAS remonter au besoin NE PAS poser le support de linteau sur des plaques de placopl tre On DOIT utiliser des ancrages de b ton pour le montage du support de linteau ou d un 2 x 4 dans la ma onnerie Ne JAMAIS tenter de desserrer d placer ou r gler la porte de garage ainsi que les ressorts c bles poulies supports de porte ou leurs ferrures de montage lesquels sont tous sous une tension EXTREME e TOUJOURS appeler un technicien form en syst mes de porte si la porte de garage force ou est d s quilibr e Une porte de garage d s quilibr e peut NE PAS remonter au besoin Les m thodes de pose varient en fonction de la porte du garage Suivre les instructions qui correspondent la porte du garage sur laquelle on pose l ouvre porte 1 2 Fermer la porte et marquer l axe vertical int rieur de la porte du garage Prolonger cet axe sur le linteau au dessus de la porte Ne pas oublier que l on peut fixer le support du linteau moins de 4 pieds 1 22 m droite ou gauche de l axe de la porte seulement si un ressort de torsion ou une plaque d appui centrale g ne ce support peut galement tre fix au plafond se reporter la page 13 si le d gagement n est pas suffisant II peut tre mont l envers sur un mur au besoin pour
16. Mod le 547445 Uniquement Mod le 547445 Uniquement Inventaire des fixations S parer toutes les fixations et les regrouper comme illustr ci apr s aux fins des op rations de montage et de pose FIXATIONS POUR LE MONTAGE o crou de chariot ressort 1 Contre c crou de Rondelle un crou de 1 4 de po 20 2 de 3 8 de po 1 3 8 de po 1 Boulon de 1 4 de po 20 x 1 3 4 de po 2 o Pm Maillon de Tige filet e du chariot 1 raccord 1 Pauen 1 FIXATIONS POUR LA POSE mm OY O Boulon t te bomb e et collet carr crou oreilles Anneau d arr t 3 crou de de 1 4 de po 20 x 1 2 de po 2 1 4 de po 20 2 5 16 de po 18 8 umm CD O n Tire fond de Boulon hexagonal de 5 16 de po 9 x 1 5 8 d 2 Rondelle frein de 16 de po 9 x 1 5 8 de po 2 5 16 de po 18 x 7 8 de po 4 5 16 de po 7 0000000000 Tire fond de am 5 16 de po 18 x 1 7 8 de po 2 AB x 1 1 4 de po 2 Agrafe isol e 30 IR M Vis autotaraudeuse Chevilles pour 1 4 de po 14 x 5 8 de po 2 murs secs 2 L LI Es Axe de chape de Axe de chape de Axe de chape de 5 16 de po x 1 1 2 de po 1 5 16 de po x 1 po 1 5 16 de po x 1 1 4 de po 1 SS RE w Poign e Corde MONTAGE 1 OP RATION Montage du rail et pose du chariot Pour viter les difficult s pendant la pose ne faire fonctionner l ouvre porte de garage que lorsque cela est express ment indiqu Le rail avant a une fen tre d coup e
17. No movement motor runs 2 3 seconds Reconnect the emergency release Motor may need to be replaced Smart Control Panel Messages The following messages are contained within the Smart Control Panel and may appear during the operations of the unit Message WII Meaning This message will appear if the Safety Reversing Sensors are out of SAFETY SENSORS CHECK alignment if they are blocked or if the wiring is disconnected To clear message from ALIGNMENT BLOCKAGE OR door control do the following geet SEE OWNER S Check to see that area is clear between the Safety Reversing Sensors Check to see that the Safety Reversing Sensors are not misaligned Realign receiving eye sensor clean lens and secure brackets Verify door track is firmly secured to wall and does not move Check to see that the Safety Reversing Sensors wires are connected to the motor unit If message has not cleared after the above checks refer to message 2 Message ES Meaning This message will appear if the Safety Reversing Sensors are miswired SAFETY SENSORS To clear the message do the following MALFUNCTION CHECK Inspect the safety reversing sensor wires for a short staple in wire correct wiring MISWIRING SEE OWNER S polarity black white wires reversed replace attach as needed MANUAL Disconnect all wires from back of motor unit Remove safety reversing sensors from brackets and shorten sensor wires to 1 2 ft 30 60 cm from back of each sensor R
18. T L COMMANDE APPUYER de programmer une t l commande suppl mentaire pour l ouvre porte SUR LE BOUTON LEARN POUR CONFIRMER Message Se e Signification Ce message appara t lorsque le bouton Prog LEARN a t appuy une MODE LEARN APPUYER seconde fois sur la commande de porte ou n importe quand sur l ouvre garage L ouvre porte SUR LE BOUTON DE LA est pr t programmer une autre t l commande en appuyant simplement sur le bouton de la TELECOMMANDE POUR LA t l commande Apr s que l ouvre porte a RECONNU la t l commande le projecteur de PROGRAMMATION travail clignote une fois Message ES e Signification Ce message appara t lorsque le bouton LOCK a t appuy et maintenu MODE VERROUILLAGE enfonc pendant plus d une seconde Cette fonction d sactive l ouvre porte en ce qu il ne TELECOMMANDE peut plus recevoir des signaux de la t l commande Pour quitter le mode LOCK appuyer VERROUILLEE APPUYER sans relacher sur le bouton pendant plus d une seconde SUR LE BOUTON LOCK VERROUILLAGE POUR ACTIVER LA TELECOMMANDE Message ao e Signification Ce message apparait lorsque le bouton LANGUAGE a t appuy Appuyer ANGLAIS FRAN AIS ET sur le bouton pour basculer sur la langue suivante disponible ESPAGNOL Message eee e Signification Ce message apparait lorsque le bouton de d tection de mouvement est DETECTION DE MOUVEMENT appuy La fonction de d tection de mouvement est activ e d sactiv
19. and begins closing the door 4 Immediately when the door begins to close press and release either the black or purple button This will stop the door Setting the DOWN position 5 Push and hold the purple button until the door reaches the desired DOWN closed position 6 Once the door is closed if there appears to be too much pressure on the door you may toggle the door back and forth using the black and purple buttons to reach the desired closed position 7 Push the door control or programmed remote control This sets the DOWN close limit and the door should open Proceed to Set the Force 4 amp WARNING Without a properly installed safety reversal system persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal System NEVER use force adjustments to compensate for a binding or sticking garage door After ANY adjustments are made the safety reversal system MUST be tested Door MUST reverse on contact with 1 1 2 3 8 cm high object or 2x4 laid flat on floor CAUTION To prevent damage to vehicles be sure fully open door provides adequate clearance Figure 2 Q LED Push and hold until the door is at desired UP position Figure 3 door at desired DOWN position Figure 4 O LED t B
20. autotaraudeuse 1 4 de po 14 x 5 8 de po Vis autotaraudeuse de 1 4 po 14 x 5 8 po Dessus de la porte int rieur du garage sup rieur de la porte Te Support mene A 8 de linteau K S O x Placement A facultatif Support de ph la porte gt i PORTE METALLIQUE Placement i DES RENFORTS 1 ee HORIZONTAUX ET VERTICAUX Rondelle de GN SONT REQUIS DANS LE CAS amp blocage de 5 16 po P D UNE PORTE DE GARAGE Dessus de la porte LEGERE EN FIBRE DE VERRE int rieur du garage Axe vertical EN ALUMINIUM EN ACIER de la porte du i EN PANNEAUX DE VERRE garage ETC NON FOURNIS sup rieur de la porte Placement facultatif Boulon t te bomb e et collet carr de 5 16 po x 2 po non fournis PORTE EN BOIS Pour une porte sans cadre expos ou pour l installation facultative utiliser des tire fonds de 5 16 po x 1 1 2 po non fournis pour fixer le support de la porte 25 POSE 13 OP RATION Fixation de la biellette de la porte au chariot Suivre uniquement les instructions se rapportant au type de porte comme illustr ci dessous et la page suivante PORTE ARTICUL E SEULEMENT e S assurer que la porte du garage est compl tement ferm e Tirer la poign e de d clenchement d urgence pour d tacher le chariot ext rieur du chariot int rieur Reculer le chariot ext rieur en l loignant de la poulie d au moins 8 po
21. ces pour la pose 40 Pi ces d assemblage du moteur 41 Accessoires 42 Remarque 43 Pi ces de r paration et service 44 Garantie 44 Cet ouvre porte de garage a t con u et test dans le but d offrir un service s r condition qu il soit install utilis entretenu et test en stricte conformit avec les instructions et les avertissements contenus dans le pr sent manuel AVERTISSEMENT M canique AVERTISSEMENT lectrique ATTENTION Lorsque vous verrez ces symboles de s curit et ces mots de signalement sur les pages suivantes ils vous aviseront de la possibilit de blessures graves ou de mort si vous ne vous conformez pas aux avertissements qui les accompagnent Le danger peut provenir de source m canique ou d un choc lectrique Lisez attentivement les avertissements Lorsque vous verrez ce mot de signalement sur les pages suivantes il vous avisera de la possibilit de dommages votre porte de garage ou ouvre porte de garage ou les deux Si vous ne vous conformez pas aux nonc s de mise en garde qui l accompagnent Lisez les attentivement Pr paration de votre porte de garage Avant de commencer A AVERTISSEMENT D sactiver les serrures Pour pr venir d ventuelles BLESSURES GRAVES ou LA Retirer toute corde raccord e la porte de garage i R aliser le test suivant pour s assurer que la porte de e TOUJOURS appeler un technicie
22. controls To Add or Reprogram a Hand Held Remote Control USING THE LEARN BUTTON 1 Press and release the learn button on the motor unit The learn indicator light will glow steadily for 30 seconds 2 Within 30 seconds press and hold the button on the hand held remote that you wish to operate your garage door 3 Release the button when the motor unit lights blink It has learned the code If light bulbs are not installed two clicks will be heard PA To Erase All Codes From Motor Unit Memory To deactivate any unwanted remote first erase all codes Press and hold the learn button on motor unit until the learn LED goes out approximately 6 seconds All previous codes are now erased Reprogram each remote or keyless entry you wish to use USING THE DOOR CONTROL 1 Press the Prog lt Learn gt button on the door control C n 2 Press the Prog Learn button again to confirm Learn Mode 3 Press the button on the hand held remote that you A wish to operate your garage door 4 When the motor unit lights S blink it has learned the code If light bulbs are not installed two clicks will be heard 3 Button Remotes 315 MHz If provided with your gara
23. courb horizontal Linteau Lint eure 8 po 20 cm BY 8 po 200m NU dy i Point de NV course Porte le plus PA haut Ferrure de nach Point de course le plus haut Pivot Porte rigide sans guides ferrure de montant Porte rig 12 ide sans guides basculant sur pivots POSE 2 OP RATION Pose du support de linteau Le support de linteau peut tre fix soit sur le mur au dessus de la porte soit sur le plafond Suivre les instructions qui r pondent le mieux aux besoins particuliers Ne pas poser le support de linteau sur des plaques de placopl tre Utiliser des ancrages de b ton non fournis pour la pose dans la maconnerie POSE DU SUPPORT DE LINTEAU AU MUR e Centrer le support par rapport l axe vertical la partie inf rieure du support tant align e avec la ligne horizontale comme illustr la fl che du support doit tre orient e vers le plafond Marquer la s rie verticale de trous de support Percer des avant trous de 3 16 de pouce et fixer fermement le support sur une solive avec les fixations fournies GRANDEUR R ELLE DES FIXATIONS Tire fond de 5 16 de po 9 x 1 5 8 de po POSE DU SUPPORT DE LINTEAU AU PLAFOND e Prolonger l axe vertical sur le plafond comme illustr Centrer le support sur l axe vertical 6 pouces 15 cm au maximum du mur S assurer que la fl amp che est orient e dans le sens oppos au mur Le support
24. dans un bo te qui contiennent le moteur et les pi ces illustr es ci apr s Les accessoires d pendront du mod le achet S il manque quoi que ce soit v rifier le mat riel d emballage pe Batterie Syst me Protector 2 Capteurs d inversion de s curit 1 oeil de transmission et 1 oeil de r ception avec fil de sonnerie blanc et blanc noir deux conducteurs fix 223 3 35 235 E d Supports de Suspension Support en U Biellette Courb e 6 6 9 e 9 6 o Biellette Support du D tecteur inverseur de s curit 2 Les pi ces peuvent tre coinc es dans la mousse Les fixations n cessaires au montage et la pose apparaissent sur la page suivante Conserver la boite et le mat riel d emballage jusqu au terme de la pose et du r glage Capuchon de maintien Courroie de la courroie Documentation et tiquettes de s curit Fil de Sonnerie blanc et blanc rouge 2 conducteurs Chariot d Support de Linteau Sections centrale arri re du rail s SECURITY T l commande trois boutons 2 Smart Control Panel SECURITY Syst me d ouverture sans cl SECURITY Mini t l commande 3 Bouton 1 Mod le 547445 Uniquement Commande d clairage Section avant linteau du rail Syst me de D tection d ouverture de porte de garage Mod le 547445 Uniquement Protecteur de Mont e Assistance de Garage Garag
25. de fil Ee l crou 2 Sile t moin de la cellule mettrice est allum alors que le t moin de la cellule r ceptrice est teint Le c blage est bien fait entre les d tecteurs et e Desserrer l crou de la cellule r ceptrice et r gler le d tecteur jusqu ce qu il recoive le faisceau de la cellule V rifier l alignement mettrice Lorsque le t moin vert reste allum serrer V rifier s il y a un fil bris dans la cellule r ceptrice l crou 3 Sile t moin de la cellule r ceptrice est faible aligner l un ou l autre des d tecteurs REMARQUE Lorsque le faisceau invisible est obstru ou mal align quand la porte se ferme cette derni re remontera Si la porte est d j ouverte elle ne se fermera pas La lumi re de l ouvre porte clignotera 10 fois Se reporter la page 20 23 POSE 12 OP RATION Fixation du support de la porte Suivre les instructions qui correspondent au type de porte comme il est illustr ci dessous ou la page suivante Un renfort horizontal doit tre suffisamment long pour tre fix deux ou trois supports verticaux Un renfort vertical doit couvrir la hauteur du panneau sup rieur La figure 1 illustre un morceau de corni re utilis en tant que renfort horizontal Pour le renfort vertical 2 morceaux de corni re sont utilis s de facon cr er un support en forme de U La meilleure solution consiste s adresser au fabricant de la porte de garage pour o
26. est mal align ou est obstru Si l ouvre porte ferme la porte lorsque le d tecteur inverseur de s curit est obstru et que les d tecteurs ne sont pas plus de 6 po 15 cm au dessus du sol appeler un technicien form en syst mes de porte 30 AVERTISSEMENT Sans un syst me d inversion de s curit bien install des personnes plus particuli rement les petits enfants pourraient tre GRIEVEMENT BLESSEES ou TUEES par une porte de garage qui se referme On DOIT proc der une v rification mensuelle du syst me d inversion de s curit Apr s avoir effectu quelque r glage que ce soit on DOIT faire l essai du syst me d inversion de s curit La porte de garage DOIT remonter au contact d un objet d une hauteur de 1 1 2 po 3 8 cm ou un 2 x 4 pos WON Planche de 1 1 2 de po ou 2 x 4 plat 3 8 cm AVERTISSEMENT Sans un syst me d inversion de s curit bien install des personnes plus particuli rement les petits enfants pourraient tre GRIEVEMENT BLESSEES ou TUEES par une porte de garage qui se referme D tecteur inverseur de s curit D tecteur inverseur de s curit FONCTIONNEMENT IMPORTANTES CONSIGNES DE S CURIT AVERTISSEMENT Pour r duire le risque de BLESSURES GRAVES ou DE MORT LIRE ET
27. et les solives Couper les deux supports de suspension la longueur requise Percer des avant trous de 3 16 de pouce dans les solives Fixer une extr mit de chaque support de suspension sur une solive avec des tire fond de 5 16 po 18 x 1 7 8 po Fixer l ouvre porte aux supports de suspension l aide de boulons hexagonaux de 5 16 po 18 x 7 8 po de rondelles frein et d crous S assurer que le rail est centr au dessus de la porte ou dans le prolongement du support de linteau si le support n est pas centr au dessus de la porte Retirer le 2 x 4 Faire fonctionner la porte manuellement Si la porte frappe le rail lever le support de linteau REMARQUE NE PAS mettre l ouvre porte sous tension ce Stade T GRANDEUR R ELLE DES FIXATIONS Tire fond de 5 16 de po 18 x 1 7 8 de po RID CO Boulon hexagonal de 5 16 de po 18 x 7 8 de po crou de 5 16 de po 18 Rondelle frein de 5 16 de po 16 AVERTISSEMENT Pour viter d ventuelles BLESSURES GRAVES par suite de la chute d un ouvre porte de garage fixer l ouvre porte SOLIDEMENT aux solives du garage On DOIT utiliser des ancrages de b ton si les supports sont pos s dans la ma onnerie Figure 1 D 4 Y S CF Mesurer X V d Vs ih Solives Tire fond de 5 16 po 18 x 1 7 8 po v la distance Boulon de 5 16 po 18 x 7 8 po Rondelle frein de 5 16 po Ecrou de 5 16 po 18 Solive Fi
28. flat on floor Figure 1 00000 LED U M Black Button Q O e it E Purple lev Button Figure 2 LED Black Button Push purple button twice to enter unit into Force Adjustment Mode Purple Button Figure 3 29 ADJUSTMENT STEP 3 Test the Safely Reversal System TEST e With the door fully open place a 1 1 2 3 8 cm board or a 2x4 laid flat on the floor centered under the garage door e Operate the door in the down direction The door must reverse on striking the obstruction ADJUST fthe door stops on the obstruction it is not traveling far enough in the down direction Complete Adjustment Steps 1 and 2 Program the Travel Limits and Set the Force NOTE On a sectional door make sure limit adjustments do not force the door arm beyond a straight up and down position See Figure 3 page 26 Repeat the test When the door reverses on the 1 1 2 3 8 cm board or 2x4 laid flat remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment e Ifthe unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY CHECK Test the Safety Reverse System after e Each adjustment of door arm length limits or force controls Any repair to or adjustment of the garage door including springs and hardware Any repair to or buckling of the garage floor Any
29. frein de 5 16 po Boulon hexagonal de 5 16 po 18 x 7 8 de po Axe de chape de 5 16 po x 1 1 4 po Support de la porte Axe de chape de 5 16 po x 1 po Chariot 26 Pa de 8 po 20 m Ge 0 Poulie Chariot i ext rieur du chariot Qro ne int rieur Axe de chape Anneau de 5 16 de d arr t po x 1 po Poign e de d clenchement d urgence Support de la porte 0000000000 Biellette droite Biellette courb e Figure 1 Axe de chape de 5 16 de po x 1 1 4 de po Poulie i Min de 8 po 20 cm gt VA Boulon d arr t du chariot crous de 5 16 de al po 18 Support de la porte Boulon hexagonal de 5 16 de po 18 x 7 8 de po Figure 2 Poulie mti de 8 po 20 cm Boulon d arr t du chariot Rondelles frein de 5 16 de po Boulon hexagonal de 5 16 de po 18 x 7 8 de po Couper cette extr mit Figure 3 MAUVAIS Biellette droite a Biellette droite Biellette courb e Rainure faisant face a l oppose Figure 4 POUR TOUTES LES PORTES RIGIDES Figure 5 1 Assemblage des biellettes IMPORTANT La rainure sur la biellette droite DOIT faire face a l oppose de la biellette courb e Figure 5 Biellette Assembler les biellettes droite et courb e leur droite plus grande longueur 2 ou 3 trous se chevauchant Rainure Figure 5 faisant face S assurer que la porte du garage e
30. gagner environ 1 2 po 1 cm Si l on doit poser le support de linteau sur un 2 x 4 au mur ou au plafond utiliser des tire fond non fournis pour s assurer que le 2 x 4 est bien retenu sur les solives comme montr sur cette page et la page 13 Ouvrir la porte son point de course le plus haut tel qu illustr Tracer une ligne horizontale d intersection sur le linteau au dessus du point le plus haut 2 po 5 cm au dessus du point le plus haut pour portes articul es et portes rigides avec rail 8 po 20 cm au dessus du point le plus haut pour portes rigides sans rail Cette hauteur permettra d obtenir un d gagement suffisant pour le passage de la partie sup rieure de la porte REMARQUE Si le nombre total de pouces centim tres d passe la hauteur disponible dans le garage utiliser la hauteur maximum ou se reporter la page 13 pour la pose au plafond Ligne du centre verti MONTAGE DU SUPPORT DE LINTEAU AU PLAFOND EN OPTION cal de la porte de garage Solives Niveau de Jg rum menuisier SS Facultatif y A La n LE e Tr 2 po Linteau 2 po l 5 cm c 6m Linteau a 17 Guide ES de Guide a course le Point de plus haut Porte course le L plus haut Porte Porte articul e avec guide Porte rigide avec guide
31. limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel e Refer to Adjustment Step 1 Program the Travel Limits 1 5 My lights will not turn off when door is open The garage door opener is equipped with a security light feature This feature activates the light on when the safety reversing sensor beam has been obstructed Refer to Operation section Using the Wall Mounted Door Control Light Feature 8 6 My motor unit hums briefly First verify that the trolley is against the stop bolt Release the door from the opener by pulling the Emergency Release Rope Manually bring the door to a closed position Loosen the belt by adjusting the outer nut 4 to 5 turns This relieves the tension 35 Sending Eye Safety Reversing Sensor Amber Indicator Light Diagnostics Located On otor Unit Button LED or Diagnostic LED Safety Reversing Sensor Receiving Eye Safety Reversing Sensor Green Indicator Light e Run the motor unit from the remote control or door control The trolley should travel towards the door and stop If the trolley re engages with the door pull the Emergency Release Rope to disengage Trolley 1 1 4 3 18 cm Re Tighten the outer nut until the trolley spring is approximately 1 1 4 3 18 cm in length If the trolle
32. mod le est situ e sur le panneau gauche de votre ouvre porte TABLE DES MATI RES Introduction 2 7 Revue des symboles de s curit et des mots de signalement 2 Pr paration de votre porte de garage 3 Outils n cessaires 3 Planification EE 4 5 Inventaire de la bo te d emballage 6 Inventaire des fixations 7 Montage 8 11 Montage du rail et pose du chariot 8 Fixation du rail sur le moteur 9 Pose de la poulie 9 Pose de la courroie et fixation du capuchon de retenue de la courroie 10 R gler la tension 525042 pra beri RR Aer 11 Pose 11 27 Instructions pour une pose en toute s curit 11 D terminer l emplacement du support de linteau 12 Pose du support de linteau 13 Fixation du rail sur le support de linteau 14 Positionnement de l ouvre porte 15 Accrochage de l ouvre porte 16 Pose de la commande de porte 17 Pose de batterie de secours 18 Pose des ampoules 18 Pose de la corde et de la poign e de d clenchement d urgence 19 Exigences lectriques 19 Pose du Syst me Pr
33. peut tre encastr dans le plafond si le d gagement n est pas suffisant Marquer les trous lat raux Percer des avant trous de 3 16 po et fixer fermement le support sur une solive du plafond l aide des fixations fournies Trous de fixation au plafond Support de linteau Ressort de la porte Montage mural Trous de montage facultatifs Linteau Ligne du centre vertical de la porte de 2 x 4 fix garage sur les poteaux Tire fond de 5 16 de po 9 x Axe 1 5 8 de po horizontaux Ressort de la porte n Porte de garage Point le plus lev de la course de la porede garage Ligne du centre vertical de la porte de garage Plafond fini 2 Ligne du centre vertical de la porte de Tire fond de 5 16 de po 9 x 1 5 8 de po Linteau centre vertical de la porte de garage POSE 3 OP RATION Fixation du rail sur le support de linteau e Positionner l ouvre porte de garage sur le plancher juste sous le support de linteau Utiliser une des boites d emballage pour le prot ger REMARQUE Si le ressort de la porte g ne il faudra demander de l aide Demander une personne de bien retenir l ouvre porte sur un support Linteau temporaire de facon que le rail ne touche pas le ressort Support de linteau Positionner le support du rail contre le support de linteau Aligner les trous des supports et les raccorder avec un axe de chape de comme il est il
34. sensor wires to 1 2 ft 30 60 cm 2 FLASHES from back each of sensor z Reattach sending eye to motor unit using shortened wires If sending eye Safety reversing sensors indicator light glows steadily attach the receiving eye wire shorted or black white N i Jn FE Align sensors if the indicator lights glow replace the wires for the sensors If e reversed a the sensor indicator lights do not light replace the safety reversing sensors 3 FLASHES ES 4 Symptom The door doesn t activate from the door control Door control or wire Inspect door control wires for a short staple in wire replace as needed shorted Disconnect wires at door control touch wires together If motor unit activates replace door control f motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white terminals with jumper wire If motor unit activates replace door control wires 4 FLASHES W Symptom Sending indicator light glows steadily receiving indicator light is dim or flashing Safety reversing sensors Realign receiving eye sensor clean lens and secure brackets slightly misaligned dim or flashing LED 5 FLASHES coo Symptom Door travels 2 3 inches and stops Motor RPM is not Reprogram limits and forces See Adjustment section recognized e If the motor unit continues to travel 2 3 inches check the travel module connection or replace the travel module Symptom
35. side is convenient for setting an ideal door to rail distance Remove foam packaging e Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and place a 2x4 on its side on the top section of the door beneath the rail The top of the door should be level with the top of the motor unit Do not position the opener more than 4 10 cm above this point CAUTION To prevent damage to garage door rest garage door opener rail on 2x4 placed on top section of door f i Door 2x4 is used to determine the correct mounting height from ceiling Header 2x4 is used to determine the correct mounting height from ceiling 15 INSTALLATION STEP 5 Hang the Opener Three representative installations are shown Yours may be different Hanging brackets should be angled Figure 1 to provide rigid support On finished ceilings Figures 2 and 3 attach a sturdy metal bracket to structural supports before installing the opener This bracket and fastening hardware are not provided 1 Measure the distance from each side of the motor unit to the structural support Cut both pieces of the hanging bracket to required lengths Drill 3 16 pilot holes in the structural supports Attach one end of each bracket to a support with 5 16 18x1 7 8
36. sir e S il s av re qu il y a trop de pression sur la porte faire basculer la porte en avant et en arri re en utilisant les boutons noir et violet pour atteindre la position d sir e Appuyer sur le poste de commande ou telecommande programm un seul bouton Ceci r glera la limite de fermeture et am nera la porte en position compl tement ouverte Poursuivez avec R glage de sensibilit 28 AVERTISSEMENT Sans un syst me d inversion de s curit bien install des personnes plus particuli rement les petits enfants pourraient tre GRIEVEMENT BLESSEES ou TUEES par une porte de garage qui se referme Un r glage erron des courses de la porte de garage g nera un fonctionnement appropri du syst me d inversion de s curit Ne JAMAIS utiliser les r glages de force pour compenser une porte qui force ou qui adh re Apr s avoir effectu quelque r glage que ce soit on DOIT faire l essai du syst me d inversion de s curit La porte de garage DOIT remonter au contact d un objet d une hauteur de 1 1 2 po 3 8 cm ou un 2 x 4 pos plat sur le sol ATTENTION Pour pr venir les dommages aux v hicules s assurer que la porte enti rement ouverte offre un d gagement suffisant Figure 2 m OH e I L nm Enfoncer et tenir jusqu ce que la porte soit la HAUTEUR d sir e Figure 3 DU Figure 4 DEL C
37. that protrude on the top and sides of the bracket HARDWARE SHOWN ACTUAL SIZE Lock Nut 1 4 20 Bolt 1 4 20x1 3 4 ASSEMBLY STEP 3 Install the Idler Pulley e Lay the belt beside the rail as shown Grasp the end with the hooked trolley connector and pass approximately 12 30 cm of belt through the window Keep the ribbed side toward the rail and allow it to hang until Assembly Step 5 Remove the tape from the idler pulley The inside center should be pre greased If dry regrease to ensure proper operation Place the idler pulley into the window as shown e Insert the idler bolt from the top through the rail and pulley Tighten with a 3 8 lock washer and nut underneath the rail until the lock washer is compressed e Rotate the pulley to be sure it spins freely e Insert a 1 4 20x1 3 4 bolt into the trolley stop hole in the front of the rail as shown Tighten securely with a 1 4 20 lock nut HARDWARE SHOWN ACTUAL SIZE Nut 3 8 Lock Nut 1 4 20 Lock Washer 3 8 CAUTION To avoid SERIOUS damage to garage door opener use ONLY those bolts fasteners mounted in the top of the opener Bolts Motor Unit Belt Pulley U Bracket Cover Bolt Protection Bolt Hole SLIDE RAIL TO STOPS ON TOP AND SIDES OF BRACKET I Lock Nut Grease Inside Pulley Lock P Washer d 3 8 Nut 3 8 Trolley Connector Bolt 1 4 20x1 3 4 Idler
38. to see if there is any binding or sticking If your door binds sticks or is out of balance call a trained door systems technician Sectional Door One Piece Door Carpenter s Level optional Tape Measure I gt L 1 3 16 5 16 and 5 32 C Sockets and Wrench 1 2 5 8 7 16 9 16 and 1 4 WARNING To prevent possible SERIOUS INJURY or DEATH ALWAYS call a trained door systems technician if garage door binds sticks or is out of balance An unbalanced garage door may NOT reverse when required NEVER try to loosen move or adjust garage door door springs cables pulleys brackets or their hardware ALL of which are under EXTREME tension Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing and operating garage door opener to avoid entanglement CAUTION To prevent damage to garage door and opener ALWAYS disable locks BEFORE installing and operating the opener ONLY operate garage door opener at 120V 60 Hz to avoid malfunction and damage Tools needed During assembly installation and adjustment of the opener instructions will call for hand tools as illustrated below 0 Pencil E Hack Saw Claw Hammer z G8 Screwdriver Adjustable End Wrench Wire Cutters SP Pliers Planning Identify the type and height of your garage door Survey your garage
39. une pile lectrique ou sur un compartiment de batterie O O 000 Statut de batterie DEL a REMARQUE Les DEL sont plus visibles si le projecteur de travail est teint DEL VERTE tat normal de tous les syst mes Une DEL verte fixe indique que la batterie est charg e bloc Une DEL clignotant indique que la batterie est en cours de charge REMARQUE Le moteur peut fonctionner si la batterie n est pas totalement charg e DEL ORANGE L alimentation secteur est interrompue et le moteur fonctionne sur alimentation batterie Une DEL fixe avec bip sonore retentissant environ toutes les deux secondes indique que le moteur est en train d activer la porte et qu il fonctionne sur alimentation batterie Une DEL clignotante avec bip sonore toutes les 30 secondes indique que la charge de la batterie est basse e La batterie se rechargera d s la restauration de l alimentation secteur Ceci sera indiqu par une DEL verte clignotante DEL ROUGE Siune DEL rouge reste allum e la restauration de l alimentation secteur et si un bip sonore retentit toutes les 30 secondes remplacer la batterie Pour optimiser la vie utile de la batterie et viter tout dommage d brancher galement la batterie si le moteur est d branch pendant n voyage ou pour toute autre p ri
40. use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced door could result in an open door falling rapidly and or unexpectedly NEVER use emergency release handle unless garage doorway is clear of persons and obstructions NEVER use handle to pull door open or closed If rope knot becomes untied you could fall DISCONNECT THE TROLLEY Trolley The door should be fully closed if possible Pull down on the emergency release handle so that the trolley release arm E emm snaps into a vertical position pose m gt and lift the door manually In Manual The ockout feature prevents Disconnect the trolley from reconnecting automatically and the door can be raised and lowered manually as often as necessary Position Lockout position Manual disconnect TO RE CONNECT THE TROLLEY Pull the emergency release handle toward the opener at an angle so that the trolley Trolley release arm is horizontal Tory The trolley will reconnect on the next UP or DOWN operation either manually or by using the door control or remote Arm Emergency Down and AN Release Handle D sS To reconnect Care of Your Opener MAINTENANCE SCHEDULE Every Month Manually operate door If it is unbalanced or binding call a trained door systems technician Check to be sure door opens amp closes fully Adjust limi
41. when garage door is CLOSED Weak or broken springs or unbalanced door could result in an open door falling rapidly and or unexpectedly NEVER use emergency release handle unless garage doorway is clear of persons and obstructions NEVER use handle to pull door open or closed If rope knot becomes untied you could fall Trolley Trolley L B Release Arm ae Overhand Emergency Knot Release Handle WARNING To prevent possible SERIOUS INJURY or DEATH from electrocution or fire Disconnect ALL electric and battery power BEFORE performing ANY service or maintenance Garage door installation and wiring MUST be in compliance with ALL local electrical and building codes NEVER use an extension cord 2 wire adapter or change plug in ANY way to make it fit outlet Be sure the opener is grounded PERMANENT WIRING CONNECTION Ground Tab Green Ground Screw Ground Wire INSTALLATION STEP 11 Install The Protector System The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR When properly connected and aligned the sensor will detect an obstacle in the path of its electronic beam The sending eye with an amber indicator light transmits an invisible light beam to the receiving eye with a green indicator light If an obstruc
42. 11 mm chaque extr mit des fils de sonnerie brancher les fils sur les deux bornes filet es qui se trouvent l arri re de la commande de porte murale blanc 2 blanc rouge 1 2 Retirer le couvercle en soulevant doucement la fente dans la partie sup rieure du couvercle l aide d un petit tournevis t te plate Fixer l aide de vis autotaraudeuses 6AB x 1 1 4 po installation standard ou de vis m taux 6 32 x 1 po dans la boite simple comme suit Percer et poser la vis inf rieure en laissant 1 8 po 3 mm au dessus de la surface Placer le bas de la commande de porte de porte par dessus la t te de vis et ajuster pour un ajustement serr Ajuster la vis pour une pose solide Percer et poser la vis sup rieure soigneusement afin d viter de fissurer le bo tier en plastique NE PAS serrer excessivement Ins rer les languettes sup rieures et enclencher le couvercle 3 Installation standard seulement Faire monter le fil de sonnerie le long du mur et du plafond jusqu au moteur Utiliser des agrafes isol es pour fixer le fil plusieurs endroits NE PAS percer le fil avec une agrafe ce qui cr erait un court circuit ou un circuit ouvert 4 D nuder 7 16 po 11 mm d isolation de l extr mit du fil de sonnerie Raccorder le fil de sonnerie aux bornes raccordement rapide comme suit le fil blanc blanc et le fil blanc rouge rouge 5 Positionnez le fil d antenne comme d crit 6 Util
43. 5 REVERSING SENSORS Mounting S e Slide a 1 4 20x1 2 carriage bolt head into the slot RU on each sensor Use wing nuts to fasten sensors to brackets with lenses pointing toward each other across the door Be sure the lens is not obstructed by a Carriage Bolt bracket extension Figure 5 1 4 20x1 2 Finger tighten the wing nuts Option A Installation Without Pre Wiring e Run the bell wire from both sensors to the garage door opener Attach the wire to the wall and ceiling with the Figure 6 staples Figure 6 Option B Pre Wired Installation If your garage already has wires installed for the safety reversing sensors follow the instructions below e Cut the end of the safety sensor wire making sure there is enough wire to reach the pre installed wires from the wall Figure 7 Separate the safety sensor wires and strip 7 16 11 mm of insulation from each end Choose two of the pre installed wires and strip 7 16 11 mm of insulation from each end Make sure that you choose the same color pre installed wires for each sensor Figure 8 Connect the pre installed wires to the sensor wires with wire nuts making sure the colors correspond for each sensor Figure 9 Figure 7 Figure 8 Safety Reversing Sensor Wires 7 16 T 11 mm Pre Installed Wires Figure 9 Not Provided Safety Reversing Sensor Wires Pre installed wires White Black 22 Connect to garage doo
44. 5 m un technicien form en syst mes de porte AVANT de poser l ouvre porte D sactiver TOUTES les serrures et retirer TOUTES les cordes raccord es la porte de garage AVANT de poser l ouvre porte afin d viter un emm lement Poser l ouvre porte de garage au moins 7 pieds 2 13 m au dessus du sol Montez la rel che d urgence proximit mais au moins 6 pieds 1 83 m au dessus du plancher pour viter le contact avec des v hicules pour d clencher la rel che par accident Ne JAMAIS raccorder l ouvre porte de garage une source de courant AVANT d avoir recu l instruction de le faire l cart de TOUTES les pi amp ces mobiles de la porte Placer l tiquette d avertissement de prise au pi ge sur le mur c t de la commande de la porte de garage Placer l tiquette d essai d inversion de s curit ouverture manuelle bien en vue l int rieur de porte de garage Au terme de la pose faire l essai du syst me d inversion de s curit La porte DOIT remonter au contact d un objet d une hauteur de 1 1 2 po 3 8 cm ou un 2 x 4 pos plat sur le sol Pour viter des BLESSURES GRAVES VOIRE MORTELLES par choc lectrique d brancher l alimentation batterie ET l alimentation secteur AVANT TOUTE r paration ou maintenance 11 POSE 1 OP RATION D terminer l emplacement du support de linteau AVERTISSEMENT Pour pr venir d ventuelles BLESSURES
45. A6357 1 Batterie NON ILLUSTR S 101D169 Barre poussoir pour commande de porte 41A5257 20 Sachet des fixations de pose comprend les fixations la page 7 11444328 Manuel d instructions 2 3 4 5 9 9 9 9 9999 40 Pi ces d assemblage du moteur z N DE z REF PIECE DESIGNATION 41C76 Capuchon de retenue de la courroie 41B4245 Cordon lectrique 41B4375 3 Bornier avec vis 41A6281 Contenu du kit de faisceau de c blage Comprend Fils de batterie et prise fils de douille d ampoule et prise fils de liaison r gime moteur avec prise 41D794 Moteur avec capteur de positionnement 41DB002 2 Plaque logique du r cepteur R F PIECE 4146231 410190 41D504 6 108D79 175B88 41A6357 1 41 D SIGNATION Panneau d extr mit avec couvercle de batterie et vis Transformateur avec harnais Couvercle Diffuseur Douille d ampoule NON ILLUSTR S Batterie ACCESSORIES 7702C D tachement rapide d ext rieur N cessaire pour un garage SANS porte d acc s Rallonge de rail de 8 pieds 2 4 m Pour permettre une porte de 8 pieds 2 4 m de s ouvrir compl tement Rallonge de rail de 10 pieds 3 m Pour permettre une porte de 10 pieds 3 m de s ouvrir compl tement Supports de rallonge Facultatif Pour la pose du capteur inverseur de s curit au mur ou au sol Pour commander composer le 1 800 528 9131 Commande d clairage Perme
46. Bolt ASSEMBLY STEP 4 Install the Belt and Attach the Belt Cap Retainer 1 Pull the belt around the idler pulley and toward the trolley The ribbed side must contact the pulley Hook the trolley connector into the retaining slot on the trolley as shown With the trolley against the screwdriver dispense the remainder of the belt along the rail length toward the motor unit and around the belt pulley The belt pulley teeth must engage the belt Check to make sure the belt is not twisted Connect the trolley threaded shaft with the master link as illustrated Push pins of master link bar through holes in end of belt and trolley threaded shaft Push master link cap over pins and past pin notches Slide clip on spring over cap and onto pin notches until both pins are securely locked in place Insert the trolley threaded shaft through the hole in the trolley Be sure the belt is not twisted Hold the belt at the trolley shaft as you thread the spring nut by hand onto the shaft until finger tight against the trolley DO NOT use any tools 7 Remove the screwdriver Position the belt cap retainer over the motor unit belt pulley as shown and fasten to the mounting plate with 8x3 8 hex screws provided Idler Pulley WARNING To avoid possible SERIOUS INJURY to fingers from moving garage door opener ALWAYS keep hand clear of belt pulley while operating opener Securely attach belt pulley cov
47. CHAMBERLAIN The Chamberlain Group Inc 845 Larch Avenue a y 4 Elmhurst Illinois 60126 1196 Mive www chamberlain com SECURITY GARAGE DOOR OPENER Models 459950 547445 HD900CD For Residential Use Only Owner s Manual W Please read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless The Protector System is connected and properly aligned Periodic checks of the opener are required to ensure safe operation The model number label is located on the left side panel of your opener TABLE OF CONTENTS Introduction 2 7 Safety symbol and signal word review 2 Preparing your garage door 3 Tools needed 3 NEIE 4 5 Carton inventory 6 Hardware inventory 7 Assembly 8 11 Assemble the rail and install the trolley 8 Fasten the rail to the motor unit 9 Install the idler pulley 9 Install the belt and attach the belt cap retainer 10 Set the tension EE 11 Installation 11 27 Installation safety instructions 11 Determine the header bracket location 12 Install the header bracket 13 Attach the rail to the header bracket 14 Position the opener 15 Hang th
48. ECTEUR INVERSEUR DE SECURITE Lorsqu il est bien raccord et align le d tecteur d tecte un obstacle dans le parcours de son faisceau lectronique La cellule mettrice avec un t moin lumineux ambre transmet un faisceau de lumi re invisible la cellule r ceptrice avec un t moin lumineux vert Si un obstacle brise le faisceau de lumi re pendant que la porte se ferme la porte s arr tera et remontera jusqu la position enti rement ouverte et les lumi res de l ouvre porte clignoteront 10 fois Les unit s doivent tre pos es l int rieur du garage de mani re ce que la cellule mettrice et la cellule r ceptrice se fassent face l une l autre de part et d autre de la porte pas plus de 6 po 15 cm au dessus du sol L une ou l autre peut tre pos e gauche ou droite de la porte pourvu que le soleil n claire jamais directement dans la cellule r ceptrice Les supports de montage sont con us en vue de leur fixation par pince sur le guide des portes de garage articul es sans fixations suppl mentaires AVERTISSEMENT S assurer que l ouvre porte de garage est hors tension AVANT de poser le d tecteur inverseur de s curit Pour pr venir des BLESSURES GRAVES ou LA MORT par suite d une porte de garage qui se ferme Raccorder et aligner correctement le d tecteur inverseur de s curit Ce dispositif de s curit requis NE DOIT PAS tre d sactiv Poser le d tecteur inverseur de
49. ENTER si le dispositif du bouton ferm a t activ Ce dispositif a t activ par le fabricant Afin d activer ou de d sactiver ce dispositif appuyez et maintenez les boutons 1 et 9 enfonc s pendant 10 secondes Le bloc de touches clignotera deux fois lorsque le bouton ferm sera activ Le bloc de touches clignotera quatre fois lorsque le bouton ferm sera d sactiv 39 PI CES DE R PARATION Pi ces d assemblage du rail R F PI CE D SIGNATION 4A1008 Maillon de raccord 41C5141 2 Chariot complet 41A5665 2 Rail complet 41B4103 Ecrou de chariot a ressort 144054 Poulie folle de la courroie 41A5250 Ensemble complet de courroie 41D598 1 Support en U NON ILLUSTR S 183A163 Coussinets d usure z N DE z REF PIECE DESIGNATION 1 4146318 Smart Control Panel 953CD T l commande trois boutons 10420 Pile au lithium 3V2032 29B137 Agrafe de pare soleil de la t l commande 41A2828 Poign e et corde pour fonctionnement d urgence 6 41B4494 1 Fil de sonnerie blanc et blanc rouge 2 conducteurs 7 41A5047 1 Support de porte avec axe de chape et fixation 8 41A5047 8 Support de linteau avec axe de chape et fixation 4145034 N cessaire de capteur de s curit cellules de r ception et de transmission avec fil de sonnerie deux conducteurs de 3 pi 9 m 178B34 Biellette droite 12B776 Supports de suspension 178B35 Biellette courb e 41A5266 1 Supports de d tecteurs inverseurs de s curit 2 41
50. Enables homeowner to operate garage door opener from outside by entering a password on a specially designed keyboard Also can add a temporary password for visitors or service persons This temporary password can be limited to a programmable number of hours or entries Garage Door Monitor Monitors the status of your garage door from inside your home Wireless Door Control Push bar light feature and auxiliary button Includes battery NOTES 43 CHAMBERLAIN SERVICE HOW TO ORDER IS ON CALL REPAIR PARTS OUR LARGE SERVICE ORGANIZATION Selling prices will be furnished on request or parts SPANS AMERICA AND CANADA will be shipped at prevailing prices and you will be billed accordingly INSTALLATION AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE SIMPLY DIAL WHEN ORDERING REPAIR PARTS ALWAYS GIVE OUR TOLL FREE NUMBER THE FOLLOWING INFORMATION e PART NUMBER PART NAME e MODEL NUMBER 1 800 528 9131 ADDRESS ORDERS TO THE CHAMBERLAIN GROUP INC Technical Support Group 6050 S Country Club Road Tucson Arizona 85706 For professional installation parts and service contact your local CHAMBERLAINS dealer Look GEN d e LUN TOLL for him in the Yellow Pages or call our Service www chamberlain com number for a list of dealers in your area 1 800 528 91 31 CHAMBERLAIN THREE YEAR LIMITED WARRANTY 10 YEAR BELT LIMITED WARRANTY amp LIFETIME MOTOR LIMITED WARRANTY The Chamberlain Group Inc Seller
51. ION Fiberglass aluminum or lightweight steel garage doors WILL REQUIRE reinforcement BEFORE installation of door bracket Contact your door manufacturer for reinforcement kit Header Bracket JE Door B SSS Bracket Wb A sz Location Q HORIZONTAL AND VERTICAL Vertical O REINFORCEMENT IS NEEDED Centerline f FOR LIGHTWEIGHT GARAGE of Garage DOORS FIBERGLASS Door ALUMINUM STEEL DOORS WITH GLASS PANEL ETC Sal NOT PROVIDED Figure 1 Vertical Reinforcement Vertical Centerline of Garage Door Bracket Self Threading Screw 1 4 14x5 8 Figure 2A 5 16 18x2 Not Provided Door Bracket Lock Washer 5 16 i Nut 5 16 18 Figure 2B Inside Edge of Door or Reinforcement Bolt 5 16 18x2 Not Provided Vertical Centerline of Garage Door UP Vertical Centerline of Garage Door Ww Self Threading p Screw 1 4 14x5 8 Figure 4 Figure 3 ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also Center the door bracket on the top of the door in line with the header bracket as shown Mark either the left and right or the top and bottom holes Metal Doors Drill 3 16 pilot holes and fasten the bracket with the 1 4 14x5 8 self threading screws provided Wood Doors Drill 5 16 hol
52. IRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH USE OR INABILITY TO USE THIS PRODUCT IN NO EVENT SHALL SELLER S LIABILITY FOR BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT Some provinces do not allow the exclusion or limitation of consequential incidental or special damages so the above limitation or exclusion may not apply to you This limited warranty gives you specific legal rights and you may also have other rights which vary from province to province 2011 The Chamberlain Group Inc 114A4328B All Rights Reserved CHAMBERLAIN The Chamberlain Group Inc 845 Larch Avenue Elmhurst Illinois 60126 1196 Whispet Die www chamberlain com of SECURITY OUVRE PORTE DE GARAGE Mod les 459950 e 547445 e HD900CD Pour R sidences Seulement Manuel d instructions W Lire attentivement ce manuel ainsi que les consignes de s curit W Apr s la pose accrocher ce manuel pr s de la porte de garage pour s y reporter ult rieurement E La porte NE SE FERMERA PAS si Le Syst me Protector n est pas branch et r gl correctement W Pour un bon fonctionnement en toute s curit de cet ouvre porte de garage le v rifier et le r gler p riodiquement m L tiquette du num ro de
53. IT D UTILISER CE PRODUIT EN AUCUN CAS LA RESPONSABILIT DU VENDEUR POUR L INOBSERVATION DE GARANTIE LA RUPTURE DE CONTRAT LA N GLIGENCE OU LA RESPONSABILIT OBJECTIVE NE POURRA EXC DER LE CO T DU PRODUIT GARANTI AUX PR SENTES NUL N EST AUTORIS ASSUMER POUR NOUS D AUTRES RESPONSABILIT S RELATIVEMENT LA VENTE DE CE PRODUIT Certaines provinces n acceptant pas l exclusion ou les restrictions relatives aux dommages sp ciaux ou indirects les restrictions ou exclusions figurant dans la pr sente garantie pourraient ne pas s appliquer La pr sente garantie limit e accorde certains droits l gaux sp cifiques l acheteur et il se peut qu il ait d autres droits qui varient d une province l autre 2011 The Chamberlain Group Inc 114A4328B Tous droits r serv s
54. JUSQU AUX ARR TS SUR LE DESSUS ET AUX Contre crou C T S DU SUPPORT Boulon de tension Tournevis Boulon Trou d arr t L Par e du chariot i A 9 eA AA Graisse a L l int rieur de la poulie Rondelle f Poulie rein de 3 8 po ee a Ecrou de 3 8 po Connecteur de chariot Poulie Contre crou Boulon de 1 4 de po 20 x 1 3 4 de po Boulon de tension MONTAGE 4 OP RATION Pose de la courroie et fixation du capuchon de retenue de la courroie Tirer la courroie autour de la poulie et vers le chariot Le c t nervur doit venir en contact avec la poulie 2 Accrocher le connecteur de chariot dans la fente de retenue sur le chariot comme illustr 3 Le chariot tant contre le tournevis distribuer le reste de la courroie le long du rail vers le moteur et autour du poulie Les dents du poulie doivent s engager dans la courroie 4 Assurez vous que la courroie ne soit pas emm l e Reconnectez la vis d ajustement avec l agrafe comme illustr e Pousser les chevilles de la barre du maillon de raccord travers les trous pratiqu s dans l extr mit de la courroie et de l arbre filet du chariot e Pousser le chapeau du maillon de raccord par dessus les chevilles et au del des encoches de cheville Faire glisser le ressort pince par dessus le chapeau et sur les encoches de cheville jusqu ce que les deux chevilles soient solideme
55. LACK Push either ec button to stop 28 ADJUSTMENT STEP 2 Set the Force The force setting measures the amount of force required to open and close the door 1 Push the purple button twice to enter into the Force Adjustment Mode The LED will flash quickly 2 Push the door control or programmed remote control The door will close DOWN 3 Push the door control or programmed remote control again The door will open UP 4 Push the door control or programmed remote control a third time to close the door DOWN The LED will stop flashing when the force has been programmed The door must travel through a complete cycle up and down in order for the force to be set properly If the garage door opener cannot open and close the door fully inspect the door to ensure that it is balanced properly and is not sticking or binding If the door is not stopping exactly where you would like it repeat Program the Travel Limits 4 amp WARNING Without a properly installed safety reversal system persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door Too much force on garage door will interfere with proper operation of safety reversal system NEVER use adjustments to compensate for a binding or sticking garage door After ANY adjustments are made the safety reversal system MUST be tested Door MUST reverse on contact with 1 1 2 3 8 cm high object or 2x4 laid
56. Lock Nut Lock Washer Nut 1 4 20 2 3 8 1 3 8 1 Bolt 1 4 20x1 3 4 2 o TT Master Trolley Threaded Shaft 1 Link 1 Idler Bolt 1 INSTALLATION HARDWARE gt wodoo qmi GE Wing D Ring Nut 5 16 18 8 1 4 20x1 2 1 4 20 2 Fastener 3 no Lag Screw si Bolt Insulated 5 16 9x1 5 8 2 5 16 18x7 8 4 Lock Washer 5 16 Staples 30 P RUE DDT CTT Screw 6 32x1 2 Lag Screw 5 16 18x1 7 8 Screw 6ABx1 1 4 2 IR M i Drywall Anchors 2 Self Bie did 1 4 14x5 8 Clevis P Clevis Pin 5 16 x1 1 2 5 16 x1 5 6 x1 1 4 RE tun Rope ASSEMBLY STEP 1 CAUTION Assemble the Rail amp Install the Trolley To avoid installation difficulties do not run the garage To prevent INJURY from pinching keep hands and door opener until instructed to do so fingers away from the joints while assembling the rail The front rail has a cut out window at the door end see illustration The hole above this window is larger on the top of the rail than on the bottom A smaller hole 3 Place the motor unit on packing material to protect 3 1 2 8 9 cm away is close to the rail edge Rotate the the cover and rest the back end of the rail on top back rail so it has a similar hole close to the opposite For convenience put a support under the front end of edge about 4 3 4 12 cm from the far end the rail 1 Remove the straight door arm and hanging bracket 4 A
57. N 39 Repair Parts 40 41 Rail assembly parts 40 Installation parts 40 Motor unit assembly parts 41 Accessories 42 Notes 43 Repair Parts and Service 44 Warranty 44 This garage door opener has been designed and tested to offer safe service provided it is installed operated maintained and tested in strict accordance with the instructions and warnings contained in this manual WARNING Mechanical WARNING Electrical CAUTION When you see these Safety Symbols and Signal Words on the following pages they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them The hazard may come from something mechanical or from electric shock Read the warnings carefully When you see this Signal Word on the following pages it will alert you to the possibility of damage to your garage door and or the garage door opener if you do not comply with the cautionary statements that accompany it Read them carefully Preparing Your Garage Door Before you begin Disable locks e Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or binding 1 Lift the door about halfway as shown Release the door If balanced it should stay in place supported entirely by its springs 2 Raise and lower the door
58. PIN then press and hold the button The opener light will blink twice Release the button 2 Press the new 4 digit PIN you have chosen then 2 Press the temporary 4 digit PIN you have chosen then press ENTER press ENTER The motor unit lights will blink once when the PIN has The opener light will blink four times been learned 3 To set the number of hours this temporary PIN will Test by pressing the new PIN then press ENTER The door work press the number of hours up to 255 then should move press To set a temporary PIN OR You may authorize access by visitors or service people 3 To set the number of times this temporary PIN will with a temporary 4 digit PIN After a programmed number work press the number of times up to 255 then of hours or number of accesses this temporary PIN press expires and will no longer open the door It can be used The opener light will blink once when the temporary PIN to close the door even after it has expired To set a has been learned temporary PIN Test by pressing the four buttons for the temporary 1 Press the four buttons for your personal entry PIN PIN then press ENTER The door should move If the not the last temporary PIN then press and hold the temporary PIN was set to a certain number of openings button remember that the test has used up one opening To clear The opener light will blink three times Release the the temporary password repeat steps 1 3 setting
59. S PORTE Extr mit sous l extr mit avant du rail Comme boutoir temporaire ins rez un tournevis dans l orifice situ 10 pouces 25 cm du devant du rail comme illustr S assurer qu il y a 4 coussinets d usure en plastique l int rieur du chariot int rieur S ils se sont d tach s durant l exp dition v rifier tout le mat riel d emballage Les remettre en place comme illustr Faire glisser l ensemble de chariot le long du rail depuis l extr mit arri re vers les tournevis Extr mit effil e Extr mit effil e Rails arri re VERS TETE DE PUISSANCE Coussinets d usure MONTAGE 2 OP RATION Fixation du rail sur le moteur Ins rer un boulon de 1 4 po 20 x 1 3 4 dans le trou du boulon de protection du couvercle l extr mit arri re du rail comme illustr Serrer fermement l aide d un contre crou de 1 4 po 20 NE PAS trop serrer Retirer les deux boulons depuis le dessus de l ouvre porte Placer le support en U c t plat dirig vers le bas sur le moteur et aligner les trous du support sur les trous de boulon Fixer l aide des boulon pr c demment retir s Aligner l ensemble de rail sur le dessus de l ouvre porte Faire glisser l extr mit du rail sur le support en U jusqu aux arr ts qui font saillie au dessus et sur les c t s du support GRANDEUR R ELLE DES FIXATIONS Contre crou 1 4 de po 20 Boulon
60. SUIVRE TOUS LES AVERTISSEMENTS ET INSTRUCTIONS TOUJOURS garder les t l commandes hors de la port e des enfants Ne JAMAIS laisser les enfants faire fonctionner les t l commandes ou les boutons poussoirs de la commande de porte ou jouer avec ceux ci Actionner la porte de garage UNIQUEMENT lorsqu on peut la voir clairement qu elle est bien r gl e et qu il n y a aucune obstacle la course de la porte TOUJOURS garder la porte de garage en vue jusqu sa fermeture compl te PERSONNE NE DOIT TRAVERSER LE PARCOURS DE LA PORTE EN MOUVEMENT PERSONNE NE DOIT PASSER SOUS UNE PORTE ARR T E EN COURS D OUVERTURE Si possible utiliser la poign e de d clenchement d urgence pour d gager le chariot UNIQUEMENT lorsque la porte de garage est FERMEE Des ressorts faibles ou bris s ou une porte d s quilibr e peuvent provoquer la chute rapide et ou impr vue d une porte ouverte et provoquer DES BLESSURES GRAVES VOIRE MORTELLES Ne JAMAIS utiliser la poign e de d clenchement d urgence moins que l entr e de garage ne soit d gag e absence de personnes et d obstacles Ne JAMAIS utiliser la poign e pour ouvrir ou fermer la porte Il y a risque de chute si le noeud de la corde se d fait Utilisation de votre ouvre porte Votre t l commande main et ouvre porte Securityse ont t r gl s en usine un code compatible qui change avec chaque usage acc dant de mani re al atoire plus de 100 m
61. T LIMIT ES UN AN LE MOTEUR ET LA COURROIE QUI SONT LIMIT S LA P RIODE DE GARANTIE LIMIT E SUR LA DUR E D UTILISATION POUR LE MOTEUR ET LA COURROIE ET AUCUNE GARANTIE IMPLICITE N EXISTERA OU NE S APPLIQUERA APR S DE TELLES DUR ES Certains provinces ne reconnaissent pas les limitations de la dur e de validit des garanties implicites Par cons quent la limitation susmentionn e peut ne pas s appliquer l utilisateur LA PR SENTE GARANTIE LIMIT E NE COUVRE PAS LES DOMMAGES NON LI S UN VICE QUELCONQUE NI LES DOMMAGES R SULTANT D UNE INSTALLATION D UN FONCTIONNEMENT OU D UN ENTRETIEN INCORRECTS NOTAMMENT ABUS USAGE ABUSIF MANQUE D ENTRETIEN RAISONNABLE ET N CESSAIRE R PARATIONS OU MODIFICATIONS QUELCONQUES NON AUTORIS ES DUDIT PRODUIT LES FRAIS DE MAIN D OEUVRE POUR LA R INSTALLATION D UNE UNIT REPAREE OU DE REMPLACEMENT LE REMPLACEMENT DES PILES ET DES AMPOULES QU D UNIT S INSTALL ES POUR UN USAGE NON R SIDENTIEL LA PRESENTE GARANTIE LIMITEE NE COUVRE PAS LES PROBLEMES RELATIFS OU CONNEXES A LA PORTE DU GARAGE OU A LA QUINCAILLERIE DE LA PORTE DU GARAGE NOTAMMENT LES RESSORTS DE LA PORTE LES GALETS DE PORTE L ALIGNEMENT DE LA PORTE OU LES CHARNI RES DES FRAIS POURRAIENT TRE IMPUT S L ACHETEUR POUR TOUTE R PARATION R SULTANT D UN PROBLEME CAUS PAR L UN DE CES ARTICLES LE VENDEUR NE SERA EN AUCUN CAS TENU RESPONSABLE DES DOMMAGES SP CIAUX OU INDIRECTS R SULTANT DE L UTILISATION OU DE L IMPOSSIBIL
62. a des fixations non fournies P POSE DE PORTE ARTICUL E I faudra poser des renforts horizontaux et verticaux dans le cas d une porte de garage l g re en fibre de verre en acier en aluminium en panneaux de verre etc Se reporter la page 24 Y a t il une porte d acc s au garage Dans la n gative le dispositif de d clenchement cl d urgence Mod le 7702C sera requis Se reporter la page des accessoires Regarder la porte de garage au point o elle rencontre le sol Tout cartement entre le sol et le bas de la porte ne doit pas d passer 1 4 de pouce 6 mm sinon le syst me inverseur de s curit pourrait ne pas fonctionner ad quatement Se reporter la 3 op ration des r glages Il faut r parer le sol ou la porte POSE DE PORTES ARTICUL ES Les panneaux de la porte sont ils en acier en aluminium en fibre de verre ou en verre Dans l affirmative des renforts horizontaux et verticaux seront requis 12 op ration de pose L ouvre porte doit tre pos au dessus de l axe de la porte S il y a un ressort de torsion ou une plaque d appui centrale dans le chemin du support de linteau il peut tre pos moins de 4 pieds 1 2 m vers la gauche ou la droite de l axe de la porte Se reporter aux 1 et 12 op rations de pose Si la porte mesure plus de 7 pieds 2 1 m de hauteur se reporter aux n cessaires de rallonge de rail indiqu s la page des accessoires PLAFOND FINI FE Une corni r
63. again To restore this feature start with the opener lights on then press and hold the light button for 10 seconds 31 until the light goes off then on again Using the Wall Mounted Door Control THE SMART CONTROL PANEL Press the push Motion Sensing button to open or ON OFF close the door Prog lt LEARN gt Press again to reverse the door during the closing cycle or to stop the door while it s opening This door control contains a motion detector that will automatically turn on the light when it detects a person entering the garage This feature can be easily turned off for extended work light use Language Degrees F C Light Feature Press the Light button to turn the opener light on or off It will not control the opener lights when the door is in motion If you turn it on and then activate the opener the light will remain on for 4 1 2 minutes Press again to turn it off sooner The 4 1 2 minute interval can be changed to 1 1 2 2 1 2 or 3 1 2 minutes as follows Press and hold the Lock button until the light blinks about 10 seconds A single blink indicates that the timer is reset to 1 1 2 minutes Repeat the procedure and the light will blink twice resetting the timer to 2 1 2 minutes Repeat again for a 3 1 2 minute interval etc up to a maximum of four blinks and 4 1 2 minutes When using the opener lights as working lights we recommend that you first disable the motion sensor LIGHT
64. age est FERMEE Des ressorts faibles ou bris s ou une porte d s quilibr e peuvent causer la chute rapide et ou impr vue d une porte ouverte Ne JAMAIS utiliser la poign e de d clenchement d urgence moins que l entr e de garage ne soit d gag e absence de personnes et d obstacle Ne JAMAIS utiliser la poign e pour ouvrir ou fermer la porte Il y a risque de chute si le noeud de la corde se d fait Chariot ans Levier de d clenchement du chariot Poign e de d clenchement d urgence AVERTISSEMENT Pour pr venir d ventuelles BLESSURES GRAVES ou LA MORT par suite d lectrocution ou d un incendie D brancher l alimentation batterie et l alimentation secteur AVANT TOUTE r paration ou maintenance a pose et le c blage de la porte de garage DOIVENT amp tre conformes tous les codes lectriques et de construction locaux Ne JAMAIS utiliser de cordon de rallonge ou d adaptateur bifilaire ni modifier la fiche de quelque mani re que ce soit pour l ins rer dans la prise S assurer que l ouvre porte est mis la terre BRANCHEMENT LECTRIQUE PERMANENT Patte de terre Vis verte de terre Fil de terre Fil blanc POSE 11 OP RATION Pose du Syst me Protector Les d tecteurs inverseurs de s curit doivent tre bien branch s et bien align s avant que l ouvre porte de garage puisse fermer la porte INFORMATIONS IMPORTANTES AU SUJET DU D T
65. airage de l ouvre porte comme clairage de travail Sinon l clairage s teindra automatiquement si les travaux s effectuent au del de la port e du d tecteur 32 prog Fonction Learn La commande de porte est quip e d un bouton Prog LEARN Reconnaissance qui facilite la reconnaissance de la t l commande par le dispositif Appuyer une fois sur le bouton Prog LEARN pour activer le mode LEARN le message suivant s affiche sur l cran Learn Remote Control Press Learn Button Again to Confirm Reconnaissance de la t l commande Appuyer de nouveau sur le bouton Prog LEARN pour confirmer Appuyer une deuxi me fois sur le bouton Prog LEARN le message suivant s affiche sur l cran Learn Mode Press Remote Control Button to Learn Remote Mode Learn Appuyer sur le bouton de la t l commande pour sa reconnaissance Appuyer sur le bouton de la t l commande programmer et le projecteur de travail clignotera pour confirmer que la t l commande a t reconnue par le dispositif Fonction Heure et Minute Appuyer sans rel cher sur l un de ces boutons lat raux pour augmenter le nombre d heures ou de minutes affich es sur l cran ACL A LANG Fonction Langue Appuyer sur ce bouton lat ral pour basculer entre trois langues disponibles anglais espagnol et fran ais Degr s Fahrenheit Celsius Appuyer sur ce bouton lat ral pour b
66. ant la pose ne pas faire fonctionner l ouvre porte pour le moment Afin de minimiser les risques de chocs lectriques le cordon d alimentation de l ouvre porte de garage comporte une fiche trois broches dont une de mise la terre Cette fiche ne peut tre branch e que dans une prise de courant mise la terre Si la fiche ne peut pas tre branch e dans la prise de courant s adresser un lectricien qualifi pour faire poser une prise de courant ad quate 2231422 SF BON MAUVAIS Si les codes municipaux exigent une installation lectrique permanente proc der comme suit Pour proc der a un branchement permanent par le trou de 7 8 po 20 cm pratiqu dans le dessus du moteur Retirer les vis du couvercle du moteur et mettre le couvercle de c t e D brancher le cordon 3 fils e Brancher le fil noir courant secteur sur la vis de la borne en laiton le fil blanc neutre sur la vis de la borne en argent puis le fil de terre sur la vis verte de terre L ouvre porte doit obligatoirement tre mis la terre e Reposer le couvercle Pour viter les difficult s pendant la pose ne pas faire fonctionner l ouvre porte pour le moment 19 AVERTISSEMENT Pour pr venir d ventuelles BLESSURES GRAVES ou LA MORT par suite de la chute d une porte de garage Si possible utiliser la poign e de d clenchement d urgence pour d gager le chariot UNIQUEMENT lorsque la porte de gar
67. area to see if any of the conditions below apply to your installation Additional materials may be required You may find it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener Depending on your requirements there are several installation steps which may call for materials or hardware not included in the carton e Installation Step 1 Look at the wall or ceiling above the garage door The header bracket must be securely fastened to structural supports Installation Step 5 Do you have a finished ceiling in your garage If so a support bracket and additional fastening hardware may be required Installation Step 11 Depending upon garage construction extension brackets or wood blocks may be needed to install sensors Installation Step 11 Alternate floor mounting of the safety reversing sensor will require hardware not provided SECTIONAL DOOR INSTALLATION Horizontal and vertical reinforcement is needed for lightweight garage doors fiberglass steel aluminum door with glass panels etc See page 24 for details Do you have an access door in addition to the garage door If not Model 7702C Emergency Key Release is required See Accessories page Look at the garage door where it meets the floor Any gap between the floor and the bottom of the door must not exceed 1 4 6 mm Otherwise the safety reversal system may not work
68. asculer entre l chelle Fahrenheit et l chelle Celsius Caract ristique suppl mentaire lorsqu utilis avec la t l commande main trois boutons Commande de l clairage de l ouvre porte Vous pouvez programmer la t l commande de mani re commander non seulement la porte mais aussi l clairage 1 La porte tant ferm e enfoncer et tenir un petit bouton de la t l commande auquel on attribuera le contr le de l clairage Continuer tenir tout en enfon ant le Bouton d clairage sur le panneau de commande de la porte Continuer tenir les deux boutons tout en enfon ant le bouton de blocage de la commande de la porte Lorsque l clairage de l ouvre porte clignote rel cher tous les boutons De courant d alimentation en attente Optional INSTRUCTIONS D UTILISATION 1 Tester la batterie install e avec le moteur Pour tester la batterie d brancher le cordon d alimentation secteur du moteur e Let moin DEL lumi re orange fixe indique que la batterie fonctionne sur son propre courant Une DEL orange clignotante avec bip sonore indique que le dispositif fonctionne sur alimentation batterie mais que la charge de la batterie est basse Pour v rifier que la batterie fonctionne correctement ouvrir et fermer la porte du garage e Rebrancher le cordon d alimentation du moteur sur la prise secteur e V rifier que la DEL verte clignote sur le CAA ce qui indique que la batterie est en
69. boutons poussoirs de la console de commande de porte ou les metteurs de la t l commande ni jouer avec Ceux ci Actionner la porte UNIQUEMENT lorsqu on la voit clairement qu elle est bien r gl e et que rien ne g ne la course de la porte TOUJOURS garder la porte de garage en vue jusqu ce qu elle soit compl tement ferm e Ne JAMAIS laisser personne croiser le chemin d une porte de garage qui se ferme Raccordements une serrure cl ext rieure Vers les bornes raccordement rapide de l ouvre porte blanc sur blanc blanc rouge sur rouge GRANDEUR R ELLE DES FIXATIONS GOUD c e GAB x 1 1 4 po installation standard Agrafe isol e M SCT mm di 6 32 x 1 po Chevilles pour murs secs installation pr c bl e Figure 1 Figure 2 POUR ENLEVER ET INSTALLATION REMETTRE LE COUVERCLE PR C BL E Pour remettre le couvercle enplace ins rer les languettes sup rieures en premier Fil de sonnerie Couvercle de conducteurs 24 V barre poussoir Pour rel cher ou ins rer le fil enfoncer la languette l aide de l extr mit du tournevis Rouge Blanc Gris POSE 7 OP RATION Pose de batterie de secours e V rifer que le moteur est d branch e Enlever le couvercle de la batterie du moteur l aide d un tournevis cruciforme e Ins rer partiellement la batterie dans le
70. btenir un n cessaire de renforts de porte afin de pouvoir poser l ouvre porte de garage REMARQUE Bon nombre de n cessaires de renforts de porte pr voient la fixation directe de l axe de chape et de la biellette de porte Le support de porte est alors inutile proc der l tape 13 PORTES ARTICUL ES 1 Centrer le support de la porte avec l axe vertical pr c demment trac et utilis pour la pose du support de linteau I convient de noter le positionnement correct de UP vers le haut comme estampill l int rieur du support 2 Positionner le bord sup rieur du support de 2 4 pouces 5 cm 10 cm plus bas que le bord sup rieur de la porte OU directement sous toute solive travers le haut de la porte 3 Marquer percer des trous et poser comme indiqu ci apr s selon la construction de votre porte Portes m talliques ou l g res utilisant une ferrure angulaire verticale entre le support du panneau de porte et le support de porte e Percer des trous de fixation de 3 16 po Fixer le support de porte l aide des deux vis autotaraudeuses de 1 4 po 14 x 5 8 po Figure 2A On peut galement utiliser deux boulons de 5 16 po des rondelles de blocage et des crous non fournis Figure 2B Portes m talliques isol es ou l g res renforc es l usine e Percer des trous de fixation de 3 16 po Fixer le support de porte l aide des vis autotaraudeuses Figure 3 Portes en bois Uti
71. cours de charge Fin du test Charger la batterie e Permettre aux accumulateurs de se charger compl tement pendant 24 a 48 heures Une batterie a pleine charge fournit du courant 12 Vcc au moteur pendant un a deux jours d utilisation normale en cas de panne de secteur Si la charge de la batterie est trop basse la batterie se d connecte automatiquement et le moteur ne fonctionnera plus sur alimentation batterie Apr s la restauration de l alimentation secteur la batterie se rechargera dans les 48 heures La vie utile d une batterie est de 3 5 ans Pour optimiser la vie utile d une batterie et viter tout dommage d brancher la batterie lorsque le moteur est d connect pendant une longue p riode REMARQUE Le fonctionnement de la porte risque d tre limit tant que la batterie n est pas charg e bloc L clairage du moteur ne s allume pas lorsque le mode batterie est activ 33 AVERTISSEMENT Pour r duire les risques d INCENDIE ou de BLESSURE D brancher l alimentation batterie et l alimentation secteur AVANT TOUTE r paration ou maintenance Pour remplacer la batterie utiliser UNIQUEMENT la r f rence Chamberlain 41A6357 1 NE PAS jeter une batterie au feu Elle risque d exploser Consulter la r glementation locale sur la mise au rebut correcte des batteries ATTENTION Munissez vous TOUJOURS de gants de protection et de protection pour les yeux quand vous travaillez sur
72. d clenchement d urgence Porte ferm e Chariot int rieur meus ext rieur Angle correct Porte inclin e vers Porte ouverte l arri re Incorrecte 27 Biellette courb e Cee Ecrous de Rondelle frein 9 16 de po 18 R GLAGES 1 OP RATION Programmation des limites de la course Le r glage de ces courses fixe les points oi la porte s arr tera lors de son ouverture ou de sa fermeture Figure 1 00000 DEL A U M Bouton noir Bouton violet Ajustez la position de la porte en utilisant les boutons noirs et violets Le noir UP ouvre la porte et le violet DOWN la ferme R glage de la position d ouverture UP 1 Appuyez sur le bouton noir jusqu ce que le t moin indicateur commence clignoter lentement puis rel chez le 2 Appuyez sur le bouton noir jusqu ce que la porte atteigne la position d ouverture d sir e REMARQUE Assurez vous que la porte s ouvre suffisamment pour permettre votre v hicule d entrer 3 Appuyer sur le poste de commande ou telecommande programm un seul bouton Ceci r gle la limite d ouverture et commence refermer la porte D s que la porte commence se refermer appuyez et rel chez soit le bouton noir ou le bouton violet Ceci arr tera la porte R glage de la position de fermeture DOWN 5 Appuyez sur le bouton violet jusqu ce que la porte atteigne la position de fermeture d
73. de 1 4 de po 20 x 1 3 4 de po MONTAGE 3 OP RATION Pose de la poulie Poser la courroie c t du rail comme illustr Saisir l extr mit avec le connecteur de chariot crochet et passer environ 12 po 30 cm de courroie travers la fen tre Garder le c t nervur vers le rail et le laisser pendre jusqu la 5 op ration de montage Retirer le ruban de la poulie Le centre int rieur doit tre pr graiss S il est sec graisser nouveau afin d assurer un bon fonctionnement Placer la poulie dans la fen tre comme illustr Ins rer le boulon de tension depuis le dessus travers le rail et la poulie Serrer l aide d une rondelle frein de 3 8 po et d un crou sous le rail jusqu compression de la rondelle frein Faire tourner la poulie pour s assurer qu elle tourne librement Ins rer un boulon de 1 4 po 20 x 1 3 4 dans le trou d arr t du chariot l avant du rail comme illustr Serrer solidement l aide d un contre crou de 1 4 po 20 GRANDEUR R ELLE DES FIXATIONS Contre crou 1 4 de po 20 Rondelle frein de 3 8 de po crou de 3 8 de po ATTENTION Afin d viter d endommager S RIEUSEMENT l ouvre porte de garage utiliser UNIQUEMENT les boulons et les fixations mont s sur le dessus de l ouvre porte Boulons Poulie courroie du moteur Support en U Trou du boulon de protection Boulon FAIRE COULISSER 5 LE RAIL
74. de de la porte est bien ancr au mur et ne bouge pas Sympt me la porte bouge de 2 3 pouces et s arr te Reprogrammez les limites et la force Voir Section Ajustements Si l operateur continue a ne bouger que de 2 a 3 pouces v rifiez la connexion du module de d placement ou remplacez ce module Sympt me Aucun mouvement le moteur est actif entre 2 et 3 secondes Reconnectez la corde de d branchement d urgence Le moteur a peut tre besoin d tre remplac 36 Messages de la Smart Control Panel Les messages suivant sont contenus dans Smart Control Panel et peuvent s afficher au cours du fonctionnement du dispositif Message ES e Signification Ce message apparait si les d tecteurs d inversion de s curit sont hors alignement obstru s ou si les c bles sont d branch s Pour effacer le message de la RIFIER L ALIGNEMENT DES Geen j D TECTEURS DE S CURIT commande de porte effectuer les op rations suivantes OBSTRUCTION OU C BLAGE V rifier que la zone entre les d tecteurs d inversion de s curit est exempte d obstacles D FECTUEUX VOIR MANUEL V rifier que les d tecteurs d inversion de s curit ne sont pas hors alignement DU PROPRI TAIRE R aligner la cellule r ceptrice nettoyer le diffuseur et bien fixer les supports V rifier que le guide de la porte est bien ancr au mur et ne bouge pas V rifier que les fils des d tecteurs d inversion de s curit sont connect s au moteur Si
75. de la plaque arri re du moteur Retirer les d tecteurs de leurs supports et raccourcir les fils des d tecteurs une longueur de 1 2 pieds 30 60 cm partir de l arri re de chaque d tecteur Rattacher la cellule de transmission au moteur l aide des fils raccourcis Si le t moin lumineux de la cellule de transmission brille de mani re constante fixer la cellule de r ception Aligner les d tecteurs si les t moins lumineux sont allum s remplacer les fils des d tecteurs Si les t moins lumineux de d tection ne s allument pas remplacer les d tecteurs de s curit Sympt me Le t moin DEL n est pas allum sur la commande de porte Inspecter la commande de porte les fils pour d tecter un court circuit agrafe dans le fil remplacer si n cessaire D connecter les fils au niveau de la commande de porte toucher les fils l un l autre Si le moteur se met en marche remplacer la commande de porte Si le moteur ne se met pas en marche d connecter les fils de la commande de porte du moteur Court circuiter momentan ment les terminaux rouge et blancs l aide d un c ble de raccord Si le moteur se met en marche remplacer les fils de la commande de porte Sympt me Le t moin lumineux metteur est allum en continu alors que le t moin lumineux r cepteur donne une lumi re faible ou clignote R aligner la cellule r ceptrice nettoyer le diffuseur et bien fixer les supports V rifier que le gui
76. djust rope length so the handle is 6 feet 1 8 m above the floor Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement Secure with an overhand knot NOTE If it is necessary to cut the rope heat seal the cut end with a match or lighter to prevent unraveling INSTALLATION STEP 10 Electrical Requirements To avoid installation difficulties do not run the opener at this time To reduce the risk of electric shock your garage door opener has a grounding type plug with a third grounding pin This plug will only fit into a grounding type outlet If the plug doesn t fit into the outlet you have contact a qualified electrician to install the proper outlet If permanent wiring is required by your local code refer to the following procedure To make a permanent connection through the 7 8 hole in the top of the motor unit e Remove the motor unit cover screws and set the cover aside Remove the attached 3 prong cord Connect the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be grounded Reinstall the cover To avoid installation difficulties do not run the opener at this time 19 4 amp WARNING To prevent possible SERIOUS INJURY or DEATH from a falling garage door If possible use emergency release handle to disengage trolley ONLY
77. e chaque pression ACTIV E DESACTIVEE du bouton Message ESS e Signification L ouvre porte fonctionne sur batterie BATTERIE DE SECOURS ACTIV E Message eee e Signification L ouvre porte fonctionne sur une batterie compl tement charg e BATTERIE DE SECOURS ACTIVEE Message ga e Signification L ouvre porte fonctionne sur une batterie faible BATTERIE FAIBLE BATTERIE DE SECOURS ACTIVEE Message SE e Signification La batterie est irr cup rable BATTERIE D FECTUEUSE REMPLACER IMM DIATEMENT LA BATTERIE VOIR LE GUIDE D UTILISATION Message Week e Signification La batterie est en cours de charge apr s avoir fonctionn en mode de secours RETABLISSEMENT DE L ALIMENTATION LA BATTERIE EST EN COURS DE CHARGE PROGRAMMATION REMARQUE Si cet ouvre porte de garage Securitysk est utilis avec une t l commande mettrice code fixe le dispositif technique que contient le r cepteur de l ouvre porte et qui procure une protection contre les vols de code se trouvera contourn Le d tenteur des droits d auteur de cet ouvre porte de garage n autorise pas l acheteur ni le fournisseur de la t l commande mettrice code fixe contourner ce dispositif technique L ouvre porte de garage a t programm en usine de mani re fonctionner avec la t l commande main fournie La porte S ouvrira et se fermera lorsqu on appuiera sur le gros bouton poussoir Ci apr s se trouvent des instructions pour programmer
78. e the door is closing oo ID lt D D Safety Reversing Sensor Invisible Light Beam 6 15 cm max Protection Area above floor Facing the door from inside the garage 20 Safety Reversing Sensor 6 15 cm max above floor INSTALLING THE BRACKETS Be sure power to the opener is disconnected Install and align the brackets so the sensors will face each other Figure 1 DOOR TRACK MOUNT RIGHT SIDE across the garage door with the beam no higher than Door 6 15 cm above the floor They may be installed in one of Track three ways as follows Um Indicator Garage door track installation preferred Light Slip the curved arms over the rounded edge of each door track with the curved arms facing the door Snap into place against the side of the track It should lie flush with the lip hugging the back edge of the track Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figures 2 and 3 Figure 2 WALL MOUNT RIGHT SIDE Place the bracket against the wall with curved arms facing the door Be sure there is enough clearance for the sensor beam to be unobstructed e If additional depth is needed an extension bracket see Sensor B
79. e GRIEVEMENT BLESSEES ou TUEES par une porte de garage qui se referme Une trop grande force sur la porte de garage g nera un fonctionnement appropri du syst me d inversion de s curit Ne JAMAIS augmenter la force au del du niveau n cessaire la fermeture de la porte Apr s avoir effectu quelque r glage que ce soit on DOIT faire l essai du syst me d inversion de s curit La porte de garage DOIT remonter au contact d un objet d une hauteur de 1 1 2 po 3 8 cm ou un 2 x 4 pos plat sur le sol Figure 1 00000 DEL U D Boutin noir Ba Q oomo CQ m Boutin CW violet Figure 2 DEL Boutin noir Appuyer deux fois sur le bouton violet pour placer l unit en mode Boutin violet de R glage de la force Figure 3 R GLAGES 3 OP RATION Contr le du syst me d inversion de s curit ESSAI e La porte tant enti rement ouverte placer une planche de 1 1 2 po 3 8 cm d paisseur ou un 2 x 4 plat sur le plancher centr e sous la porte de garage Fermer la porte La porte doit remonter d s qu elle touche l obstacle R GLAGE Sila porte s arr te sur l obstacle sa course de fermeture n est pas suffisante Complet R glages 1 et Ze Programmation des limites de la course et R glage de sensibilit REMARQUE Dans le cas d une porte articul e s assurer que les r glages ne forcent pas sur la biellette ni l ouverture ni la fe
80. e bracket on the vertical centerline with the bottom edge of the bracket on the horizontal line as shown with the arrow pointing toward the ceiling e Mark the vertical set of bracket holes Drill 3 16 pilot holes and fasten the bracket securely to a structural support with the hardware provided HARDWARE SHOWN ACTUAL SIZE jut Lag Screw 5 16 9x1 5 8 CEILING HEADER BRACKET INSTALLATION Extend the vertical centerline onto the ceiling as shown Center the bracket on the vertical mark no more than 6 15 cm from the wall Make sure the arrow is pointing away from the wall The bracket can be mounted flush against the ceiling when clearance is minimal e Mark the side holes Drill 3 16 pilot holes and fasten bracket securely to a structural support with the hardware provided Door Wall Mount Optional Mounting Holes Vertical Header Wall Centerline of Garage 2x4 Door Structural Support Lag Screws 1 5 16 9x1 5 8 Horizontal Line lt Door Spring a Highest Point of Garage Door Travel Garage Door Vertical Centerline of Garage Door 2 Finished Ceiling a L Vertical Centerline of Garage Door Lag Screws 5 16 9x1 5 8 Header Wall Garage Door x Vertical Centerline of Garage Door INSTALLATION STEP 3 Attach the Rail to the Header Bracket Position the opener on the garage floor below the header bracket Use pack
81. e door might NOT reverse when required DO NOT install header bracket over drywall Concrete anchors MUST be used if mounting header bracket or 2x4 into masonry NEVER try to loosen move or adjust garage door springs cables pulleys brackets or their hardware ALL of which are under EXTREME tension ALWAYS call a trained door systems technician if garage door binds sticks or is out of balance An unbalanced garage door might NOT reverse when required Installation procedures vary according to garage door types Follow the instructions which apply to your door 1 Close the door and mark the inside vertical centerline of the garage door 2 Extend the line onto the header wall above the door You can fasten the header bracket within 4 feet 1 22 m of the left or right of the door center only if a torsion spring or center bearing plate is in the way or you can attach it to the ceiling see page 13 when clearance is minimal It may be mounted on the wall upside down if necessary to gain approximately 1 2 1 cm If you need to install the header bracket on a 2x4 on wall or ceiling use lag screws not provided to securely fasten the 2x4 to structural supports as shown here and on page 13 3 Open your door to the highest point of travel as shown Draw an intersecting horizontal line on the header wall above the high point e 2 5 cm above the high point for sectional door and one piece door with
82. e et des M fixations peuvent tre pour plus de d tails P requises Se reporter la page 16 T Linteau Ressort de Moteur Ressort OU traction de torsion pon D IR Porte F d acc s Ligne du centre SS F vertical de la E ll porte de garage a Commande de porte O Support de e murale linteau CORTE FERME Boulon d arr t po e i du chariot Chariot d T sis D tecteur L espace entre le plancher et inverseur de s curit Courroie le bas de la porte ne doit pas d passer 1 4 po 6 mm D tecteur inverseur de s curit Poign e et corde de d clenchement d urgence Biellette Support courb e de porte Porte de garage Planification Suite POSE DE PORTE RIGIDE En r gle g n rale une porte rigide ne n cessite aucun renfort Pour une porte l g re pri re de se reporter aux informations ayant trait aux portes articul es la 12 op ration de pose En fonction de la construction de la porte des fixations suppl mentaires seront peut tre requises pour le support de la porte 12 op ration PORTE RIGIDE SANS GUIDES j L espace entre le plancher et D tecteur inverseur le bas de la porte ne doit tre de s curit sup rieur 1 4 de po 6 mm PORTE RIGIDE AVEC GUIDES
83. e inner trolley Slide the outer trolley back away from the pulley about 8 20 cm Figures 1 2 and 3 e Figure 1 Fasten straight door arm section to outer trolley with the 5 16 x1 clevis pin Secure the connection with a ring fastener Fasten curved section to the door bracket in the same way using the 5 16 x1 1 4 clevis pin IMPORTANT The groove on the straight door arm MUST face away from the curved door arm Figure 4 e Figure 2 Bring arm sections together Find two pairs of holes that line up and join sections Select holes as far apart as possible to increase door arm rigidity e Figure 3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Bring arm sections together Find two pairs of holes that line up and join with bolts lock washers and nuts Pull the emergency release handle toward the opener at a 45 angle so that the trolley release arm is horizontal Proceed to Adjustment Step 1 page 28 Trolley will re engage automatically when opener is operated HARDWARE SHOWN ACTUAL SIZE Nut 5 16 18 Clevis Pin Ring Fastener Lock Washer 5 16 Hex Bolt 5 16 18x7 8 5 16 x1 1 4 Door Bracket ee Clevis Pin 5 16 x1 Trolley Trolley Stop Bolt Outer Trolley Clevis Pin 5 16 x1
84. e opener 16 Install the door control 17 Install the battery 18 Install the lights 18 Attach the emergency release rope and handle 19 Electrical requirements 19 Install The Protector System 20 23 Fasten the door bracket 24 25 Connect the door arm to the trolley 26 27 INTRODUCTION Safely Symbol and Signal Word Review Adjustment 28 30 Program the travel limits 28 SEUNG ONCE a vo ot Ade ens 29 Test the safety reversal system 30 Test The Protector System 30 Operation 31 37 Operation safety instructions 31 Using your garage door opener 31 Using the wall mounted door control 32 Standby power unit Optional 33 To open the door manually 34 Care of your opener 34 Having a problem Troubleshooting 35 Diagnostic chart 36 Smart Control Panel Messages 37 Programming 38 39 To add or reprogram a hand held remote control 38 To erase all codes from motor unit memory 38 3 Button remotes 38 To add reprogram or change a Keyless Entry PI
85. e t l commande non d sir e effacer munie votre t l commande sert au fonctionnement de d abord tous les codes l ouvre porte de garage Les boutons suppl mentaires DESS 5 A MA Enfoncer et tenir le bouton learn BR sur n importe quelle t l commande ou t l commande du moteur jusqu ce que le DEL je miniature trois boutons det A learn s teigne environ 6 secondes L Security peuvent tre e programm s pour faire fonctionner d autres ouvre portes de garage Security Tous les codes pr c dents sont maintenant effac s Reprogrammer chaque t l commande ou entr e sans cl qu on d sire utiliser Pour ajouter reprogrammer ou modifier un NIP d entr e sans cl REMARQUE Votre nouvelle entr e sans cl doit tre programm e de mani re faire fonctionner votre ouvre porte de garage UTILISATION DU BOUTON LEARN D Enfoncer et tenir le bouton Dans un d lai de 30 secondes learn sur le moteur Le t moin lumineux learn s allumera en continu pendant 30 secondes introduire un num ro d identification personnelle NIP quatre chiffres de son choix sur le pav num rique Enfoncer et tenir ensuite le bouton UTILISATION DE LA COMMANDE DE PORTE UL REMARQUE Cette m thode n cessite deux personnes si le pav pour l entr e sans cl est d j mon
86. eattach sending eye to motor unit using shortened wires If sending eye indicator light glows steadily attach the receiving eye Align sensors if the indicator lights glow replace the wires for the sensors If the sensor indicator lights do not light replace the safety reversing sensors Message ES Meaning This message will appear when the LEARN button has been pressed on LEARN REMOTE CONTROL the door control Pressing the LEARN button again will allow the user to program an PRESS LEARN BUTTON TO additional remote control to the opener CONFIRM Message ES Meaning This message will appear when the LEARN button has been pressed a LEARN MODE PRESS second time on the door control or any time on the opener The opener is ready to REMOTE CONTROL BUTTON program another remote control by simply pressing the remote control button Once TO PROGRAM REMOTE the opener has LEARNED the remote control the worklight will blink one time Message ES Meaning This message will appear when the LOCK button has been pressed and LOCK MODE REMOTE held for more than one second This feature will disable the opener from receiving CONTROL LOCKED OUT remote control signals To exit LOCK mode press and hold the button for more than PRESS LOCK BUTTON TO one second ENABLE REMOTE Message ES Meaning This message will appear when the LANGUAGE button has been pressed ENGLISH FRAN AIS AND Pressing the button will toggle to the nex
87. emove the lens Install a 100 watt maximum light bulb in each socket Light bulb size should be A19 standard neck only The lights will turn ON and remain lit for approximately 4 1 2 minutes when power is connected Then the lights will turn OFF Reverse the procedure to close the lens Use A19 standard neck garage door opener bulbs for replacement NOTE Use only standard light bulbs The use of short neck or speciality light bulbs may overheat the endpanel or light Socket CAUTION ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment Battery Cover CAUTION To prevent possible OVERHEATING of the endpanel or light socket DO NOT use short neck or specialty light bulbs DO NOT use halogen bulbs Use ONLY incandescent To prevent damage to the opener DO NOT use bulbs larger than 100W ONLY use A19 size bulbs 100 Watt Max Standard Light eg Release Tab Lens Hinge 100 Watt Max Standard Light Bulb 18 INSTALLATION STEP 9 Attach the Emergency Release Rope and Handle Thread one end of the rope through the hole in the top of the red handle so NOTICE reads right side up as shown Secure with an overhand knot at least 1 2 5 cm from the end of the rope to prevent slipping Thread the other end of the rope through the hole in the release arm of the outer trolley A
88. ent manuel Position verrouillage Position de d gagement manuel POUR R ENCLENCHER LE CHARIOT Tirer la poign e de d clenchement d urgence vers le bas et l arri re vers l ouvre porte de garage de facon que la biellette de d gagement du chariot soit horizontale Le chariot se r enclenchera lors de la prochaine OUVERTURE ou FERMETURE de la porte Chariot Biellette de d gagement wc Poign e de du chariot d clenchement d urgence En bas 7207 et de retour SR Pour r enclencher Entretien de votre ouvre porte P RIODICIT S D ENTRETIEN Chaque ann e Faire fonctionner la porte la main Si elle est d s quilibr e ou si elle force appeler un technicien form en syst mes de porte e S assurer que la porte s ouvre et se ferme compl tement Au besoin r gler les commandes de course et ou de force se reporter aux pages 28 et 29 R p ter l essai du syst me d inversion de s curit Proc der tous les r glages n cessaires se reporter la 3 op ration des R glages Chaque ann e Huiler les galets les roulements et les charni res de la porte Il n est pas n cessaire de lubrifier l ouvre porte de garage Ne pas graisser les guides de la porte Pour pr venir d ventuelles BLESSURES GRAVES ou LA MORT Ne JAMAIS laisser de petits enfants proximit des piles Aviser imm diatement un m decin en cas d ingestion d une pile Pour r duire le
89. er BEFORE operating HARDWARE SHOWN ACTUAL SIZE STI Hex Screw 8x3 8 Spring Trolley Nut Master Link Clip On Spring Master Link Cap Master Threaded Shaft Link Bar Trolley Hole Retaining Trolley Slot Connector 8x3 8 Hex Screws Belt Cap Retainer Motor Unit Belt Pulley Mounting 10 ASSEMBLY STEP 5 Set the Tension e Insert a screwdriver tip into one of the nut ring slots and brace it firmly against the trolley Place a 7 16 open end wrench on the square end Rotate the nut about 1 4 turn until the spring releases and snaps the nut ring against the trolley This sets the spring to optimum belt tension You have now finished assembling your garage door opener Please read the following warnings before proceeding to the installation section INSTALLATION Square Trolley End Nut Ring Nut Ring BEFORE AFTER RELEASE S 1 ox EM 1 1 4 2 5 cm 3 18 cm IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk of SEVERE INJURY or DEATH READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS Install garage door opener ONLY on properly balanced and lubricated garage door An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH ALL repairs to cables spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener D
90. er TOUTE SURCHAUFFE ventuelle du panneau d clairage NE PAS utiliser d ampoules col court ou de forme sp ciale NE PAS utiliser d ampoules halog ne Utiliser UNIQUEMENT des ampoules incandescentes Pour emp cher des dommages l ouvre boite NE PAS utiliser d ampoule plus grandes que 100W SEULEMENT utiliser A19 ampoules de taille Ampoule standard de 100 W max pap Languette de d gagement Charni re de diffuseur Ampoule standard de 100 W max 18 POSE 9 OP RATION Pose de la corde et de la poign e de d clenchement d urgence Faire passer une extr mit de la corde dans le trou sup rieur de la poign e rouge de facon que le mot NOTICE puisse tre lu l endroit Fixer l aide d un n ud simple au moins 1 po 2 5 cm de l extr mit de la corde pour emp cher le glissement e Passer l autre extr mit de la corde dans le trou du levier de d clenchement du chariot ext rieur e Ajuster la longueur de la corde de fa on que la poign e soit environ 6 pieds 1 8 m du sol S assurer que la corde et la poign e ne risquent pas de toucher au capot d aucun v hicule pour viter qu elle s emm le Fixer la corde l aide d un n ud simple REMARQUE Si la corde doit tre coup e br ler l g rement l extr mit coup e pour emp cher qu elle s effiloche POSE 10 OP RATION Exigences lectriques Pour viter les difficult s pend
91. er l emballage en mousse e Lever l ouvre porte et le faire reposer sur un escabeau Si l escabeau n est pas assez haut demander de l aide e Ouvrir compl tement la porte et mettre un 2 x 4 de c t sur le dessus de la porte sous le rail e Le haut de la porte doit tre la m me hauteur que le dessus du moteur Ne pas positionner l ouvre porte plus de 4 pouces 10 cm au dessus de ce point ATTENTION Pour pr venir les dommages la porte de garage faire reposer le rail de l ouvre porte de garage sur un 2 x 4 plac sur la section sup rieure de la porte 15 f Porte Le 2 x 4 est utilis pour d terminer la hauteur de fixation correcte partir du plafond Support de linteau Dessus de la porte Y I o o T Le 2 x 4 est utilis pour d terminer la hauteur de fixation 3 correcte partir du plafond POSE 5 OP RATION Accrochage de l ouvre porte Les illustrations repr sentent trois poses types La pose peut toutefois amp tre diff rente Les supports de suspension doivent tre inclin s Figure 1 pour assurer un support rigide Dans le cas d un plafond fini Figure 2 et Figure 3 fixer une corni re aux solives du plafond avant de poser l ouvre porte La corni re et les fixations ne sont pas fournies 1 Mesurer de chaque c t de l ouvre porte la distance entre l ouvre porte
92. erseur de 3 Pour relacher ou ins rer i 1 s curit le fil enfoncer la languette e i l aide de l extr mit du H tournevis 1 T ie Aire de protection Rouge Blanc Gris du faisceau du Bornes raccordement rapide D tecteur inverseur umi re invisible de s curit MONTAGE ET CABLAGE DES D TECTEURS INVERSEURS DU D PANNAGE DES D TECTEURS INVERSEURS DU S CURIT SECURITIE 1 Si lorsque la pose est termin e le t moin de la cellule e Brancher l ouvre porte dans la prise de courant Les mettrice ne reste pas constamment allum apr s t moins des cellules mettrice et r ceptrice s allumeront l installation s assurer et resteront allum s si les connexions lectriques sont e Que le courant lectrique parvient bien l ouvre porte bonnes et si alignement est Don 9 eee Qu il n y a pas de court circuit dans les fils blanc ou Le t moin lumineux ambre de la cellule mettrice s allumera blanc noir Ces court circuits peuvent se produire sous ind pendamment de l alignement ou de l obstruction Si le les agrafes ou la hauteur des branchements desbornes t moin lumineux vert de la cellule r ceptrice est teint faible filet es ou clignotant et que la trajectoire du faisceau lumineux invisible n est pas obstru e aligner les deux d tecteurs Pouvre porte Desserrer l crou de la cellule mettrice et ajuster de fa on ce qu elle vise directement la cellule r ceptrice Serrer Qu i n y a pas
93. es and use 5 16 x2 carriage bolts lock washers and nuts not provided or 5 16 x1 1 2 lag screws not provided depending on your installation needs NOTE The door bracket may be installed on the top edge of the door if required for your installation Refer to the dotted line optional placement drawing HARDWARE SHOWN ACTUAL SIZE Self Threading Screw 1 4 14x5 8 Self Threading Centerline of Bracket 7 NOT PROVIDED Screw Finished Ceiling Door 1 4 14x5 8 Re Header Wall Bracket Top of Door 2x4 Support Inside Garage E ET C S CFF i Optional Placement H FT Bracket S Im Optional HORIZONTAL AND VERTICAL SED REINFORCEMENT IS NEEDED Gester FOR LIGHTWEIGHT GARAGE DOORS FIBERGLASS i ALUMINUM STEEL DOORS Top of Door Vertical WITH GLASS PANEL ETC et hk Inside Garage Garage Door Top Edge of Door Optional Placement Carriage Bolt 5 16 x2 Not Provided For a door with no exposed framing WOOD DOOR or for the optional installation use lag screws 5 16 x1 1 2 Not Provided to fasten door bracket 25 INSTALLATION STEP 13 Connect Door Arm to the Trolley Follow instructions which apply to your door type as illustrated below and on the following page SECTIONAL DOORS ONLY Make sure garage door is fully closed Pull the emergency release handle to disconnect the outer trolley from th
94. et gauche la m me distance vers l ext rieur depuis la surface de montage S assurer qu il n y a aucun obstacle de ferrure de porte Pose au sol Figure 4 Utiliser des blocs en bois ou des supports de rallonge se reporter la section Accessoires pour lever les supports de d tecteur de mani re ce que les diffuseurs ne soient pas plus de 6 po 15 cm au dessus du sol Mesurer soigneusement et placer les ensembles droit et gauche la m me distance vers l ext rieur depuis le mur S assurer qu il n y a aucune obstruction de ferrure de porte e Fixer au sol l aide des ancrages de b ton comme illustr GRANDEUR R ELLE DES FIXATIONS Sc t Boulon t te bomb e et collet Ecrou oreilles carr de 1 4 de po 20 1 4 de po 20 x 1 2 de po Agrafes isol es 21 Figure 1 MONTAGE SUR GUIDES DE PORTE C T DROIT Guide de porte Rebord I T moin Figure 2 MONTAGE MURAL C T DROIT Attachez le morceau de bois au mur avec des tire fond Non fournis T moin lumineux Support de d tecteur Cmm Tire fond de 7 Non fournis Diffuseur Figure 3 MONTAGE MURAL C T DROIT Support de rallonge sid i Voir Accessoires Lag wall Fournis avec support de rallonge Support de d tecteur Fournis avec support Diffuseur T moin de rallonge lumineux Figure 4 MONTAGE AU SOL C T DROIT Fi
95. f you wish to deactivate any remote follow the instructions in the Programming section Activate your opener with any of the following e The Hand Held Remote Control Hold the large push button down until the door starts to move e The Wall Mounted Door Control Hold the push button or bar down until the door starts to move e The Keyless Entry See Accessories If provided with your garage door opener it must be programmed before use See Programming When the opener is activated with the safety reversing sensor correctly installed and aligned 1 If open the door will close If closed it will open 2 If closing the door will reverse 3 If opening the door will stop 4 f the door has been stopped in a partially open position it will close 9 If one control force or travel limits is adjusted the other control may also need adjustment 10 After ANY adjustments are made the safety reversal system MUST be tested 11 Safety reversal system MUST be tested every month Garage door MUST reverse on contact with 1 1 2 3 8 cm high object or a 2x4 laid flat on the floor Failure to adjust the garage door opener properly may cause SEVERE INJURY or DEATH ALWAYS KEEP GARAGE DOOR PROPERLY BALANCED see page 3 An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH ALL repairs to cables spring assemblies and other hardware ALL of which are under EXTREME tensio
96. ge door opener the large button is factory programmed to operate it Additional buttons on any Security 3 button remote or mini remote e can be programmed to operate other Security garage door openers To Add Reprogram or Change a Keyless Entry PIN NOTE Your new Keyless Entry must be programmed to operate your garage door opener USING THE LEARN BUTTON USING THE DOOR CONTROL 1 Press and release the learn button on motor unit The learn indicator light will glow steadily for 30 seconds Entry is already mounted outside the garage 1 Press the Prog Learn button on the door control 2 Within 30 seconds enter a four digit personal identification number PIN of your choice on the keypad Then press and hold 2 Press the Prog Learn button again to confirm Learn Mode the ENTER button 3 Enter a four digit personal 3 Release the button when the ed den ee motor unit lights blink It has N your ANA On tne ROYAL nen learned the code If light bulbs GER m press ENTER are not installed two clicks will N be heard To change an existing known PIN 4 id abu ee d Ee If the existing PIN is known it may be changed by one light bulbs are not installed two person without using a ladder clicks will be heard 7 S 1 Press the four buttons for the present
97. gure 2 cach e PLAFOND FINI Corni re Non fournie __ Boulon de 5 16 po 18 x 7 8 po Rondelle frein de 5 16 po Ecrou de 5 16 po 18 RTS Non fournis Boulon de 5 16 po 18 x 7 8 de po Rondelle frein de 5 16 po Ecrou de 5 16 po 18 Figure 3 Tire fond de 5 16 po 18 x 1 7 8 po Boulon de 5 16 po 18 x 7 8 po Rondelle frein de 5 16 po Ecrou de 5 16 po 18 SS Non fournis Boulon de 5 16 po 18 x 7 8 de po Rondelle frein de 5 16 po Ecrou de 5 16 po 18 POSE 6 OP RATION Pose de la commande de porte Poser la commande de porte murale dans un endroit o on pourra la voir de la porte au moins 5 pieds 1 5 m du sol l o les enfants ne pourront pas l atteindre et loin de toutes les pi amp ces mobiles et fixations de la porte Si les murs sont des murs secs percer des trous de 5 32 pouce Figure 1 et utiliser les chevilles fournies Pour les installations pr c bl es comme dans la construction d une maison neuve on peut la monter sur une bo te simple Figure 2 REMARQUE La temp rature de fonctionnement de la console est comprise entre 20 C 4 F et 450 C 1122 F La vitesse de d filement de commande de la porte est plus lente basse temp rature mais la console reste enti rement op rationnelle ATTENTION L exposition continue de commande de la porte des temp ratures inf rieures 30 C 22 F risque d endommager l cran ACL 1 D nuder 7 16 pouce
98. illiards de nouveaux codes Votre ouvre porte fonctionnera avec un nombre allant jusqu huit t l commandes Security et un syst me d entr e sans cl Si vous achetez une nouvelle t l commande ou que vous d sirez d sactiver toute t l commande suivez les instructions de la section Programmation Actionner l ouvre porte suivant l une des m thodes ci apr s e La t l commande main Appuyer sur le bouton poussoir jusqu ce que la porte commence se d placer Lacommande de porte murale Tenir la barre ou le bouton poussoir enfonc jusqu ce que la porte commence se d placer Le syst me d entr e sans cl se reporter la section Accessoires s il est fourni avec votre ouvre porte de garage il doit tre programm avant usage Se reporter la section Programmation Lorsque l on actionne l ouvre porte de garage et que les d tecteurs inverseurs de s curit sont correctement install s et align s 1 Si la porte est ouverte elle se fermera Si elle est ferm e elle S ouvrira 2 Si la porte est en course de fermeture elle remontera 3 Si la porte est en course d ouverture elle s arr tera 4 Si on l a arr t e en position partiellement ouverte elle se fermera 9 Apr s avoir r gl une commande force ou course il peut tre n cessaire de r gler l autre commande 10 Apr s avoir effectu quelque r glage que ce soit on DOIT faire l essai du syst me d inversion de s
99. ilt parts at Seller s sole option ALL IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE THREE YEAR LIMITED WARRANTY PERIOD SET FORTH ABOVE EXCEPT THE IMPLIED WARRANTIES WITH RESPECT TO THE BELT AND MOTOR WHICH ARE LIMITED IN DURATION TO THE BELT 10 YEARS AND MOTOR LIFETIME LIMITED WARRANTY PERIOD FOR THE BELT AND MOTOR AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD Some provinces do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you THIS LIMITED WARRANTY DOES NOT COVER NON DEFECT DAMAGE DAMAGE CAUSED BY IMPROPER INSTALLATION OPERATION OR CARE INCLUDING BUT NOT LIMITED TO ABUSE MISUSE FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT REPLACEMENT OF BATTERIES AND LIGHT BULBS OR UNITS INSTALLED FOR NON RESIDENTIAL USE THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH OR RELATING TO THE GARAGE DOOR OR GARAGE DOOR HARDWARE INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS DOOR ROLLERS DOOR ALIGNMENT OR HINGES THIS LIMITED WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU UNDER NO C
100. ing material as a protective base NOTE If the door spring is in the way you will need help Have someone hold the opener securely on a Header Wall temporary support to allow the rail to clear the spring Header Bracket e Position the rail bracket against the header bracket Align the bracket holes and join with a clevis pin as shown e Insert a ring fastener to secure Idler Pulley Ring Fastener Header Bracket Mounting Hole Opener Carton or Temporary Support HARDWARE SHOWN ACTUAL SIZE a O Clevis Pin 5 16 x1 1 2 Ring Fastener 14 INSTALLATION STEP 4 Position the Opener Follow instructions which apply to your door type as illustrated SECTIONAL DOOR OR ONE PIECE DOOR WITH TRACK A 2x4 laid flat is convenient for setting an ideal door to rail distance Remove foam packaging e Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and place a 2x4 laid flat on the top section beneath the rail e Ifthe top section or panel hits the trolley when you raise the door pull down on the trolley release arm to disconnect inner and outer sections Slide the outer trolley toward the motor unit The trolley can remain disconnected until Installation Step 12 is completed lN Cote Co MID UT Trolley TUJ a Release Arm ENGAGED RELEASED ONE PIECE DOOR WITHOUT TRACK A 2x4 on its
101. isable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener to avoid entanglement Install garage door opener 7 feet 2 1 m or more above floor Mount the emergency release within reach but at least 6 feet 1 8 m above the floor and avoiding contact with vehicles to avoid accidental release NEVER connect garage door opener to power source until instructed to do so 8 NEVER wear watches rings or loose clothing while installing or servicing opener They could be caught in garage door or opener mechanisms Install wall mounted garage door control within sight of the garage door out of reach of children at minimum height of 5 feet 1 5 m e away from ALL moving parts of the door Place entrapment warning label on wall next to garage door control Place manual release safety reverse test label in plain view on inside of garage door Upon completion of installation test safety reversal system Door MUST reverse on contact with a 1 1 2 3 8 cm high object or a 2x4 laid flat on the floor To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution disconnect ALL electric and battery power BEFORE performing ANY service or maintenance INSTALLATION STEP 1 Determine the Header Bracket Location WARNING To prevent possible SERIOUS INJURY or DEATH Header bracket MUST be RIGIDLY fastened to structural support on header wall or ceiling otherwise garag
102. iser des punaises ou des agrafes pour fixer en permanence l tiquette d avertissement de prise au pi ge sur le mur pr s de la commande de porte de porte et l tiquette d essai d inversion de s curit ouverture manuelle bien en vue l int rieur de la porte de garage REMARQUE NE PAS brancher et faire fonctionner l ouvre porte pour le moment Le chariot se d placera jusqu la position compl tement ouverte mais ne reviendra pas la position ferm e avant que le faisceau d tecteur soit branch et correctement align Trou de fixation sup rieur D nuder le fil sur Fil de Bornes 7 16 po 11 mm SE i filet es 7 6 po 11 mm gt 2 ACT Trou de JO fixation xl LE al inf rieur ARRIERE Connexions de commande de porte A AVERTISSEMENT Pour pr venir d ventuelles BLESSURES GRAVES ou LA MORT par suite d lectrocution D brancher l alimentation batterie et l alimentation secteur AVANT TOUTE r paration ou maintenance Raccorder UNIQUEMENT des fils basse tension 24 V Pour pr venir d ventuelles BLESSURES GRAVES ou LA MORT par suite d une porte de garage qui se ferme Poser la commande de la porte en vue de la porte de garage hors de la port e des enfants une hauteur minimum de 5 pieds 1 5 m et l cart de TOUTES les pi amp ces mobiles de la porte Ne JAMAIS laisser des enfants faire fonctionner les
103. jusqu 255 Faire un essai en introduisant le nouveau NIP puis appuyer puis appuyer sur sk sur ENTER La porte devrait bouger DU Pour d finir un NIP temporaire 3 Pour d finir le nombre de fois de validit de ce NIP temporaire appuyer sur le nombre de fois jusqu 255 puis appuyer sur L clairage de l ouvre porte clignotera une fois lorsque ce NIP temporaire aura t appris Faire un essai en entrant les quatre chiffres correspondant ce NIP temporaire puis appuyer sur ENTER La porte devrait bouger Si le NIP temporaire a t d fini pour un certain nombre d ouvertures ne pas oublier que le test a utilis une ouverture Pour effacer le mot de passe temporaire r p ter les tapes 1 3 en d finissant le nombre d heures ou de fois 0 lors de l tape 3 Vous pouvez autoriser l acc s aux visiteurs ou aux techniciens de service l aide d un NIP temporaire 4 chiffres Apr s un nombre programm d heures ou un nombre programm d utilisations ce NIP temporaire vient expiration et n ouvre plus la porte On peut l utiliser pour fermer la porte une fois qu il a expir Pour d finir un NIP temporaire 1 Appuyer sur les quatre boutons correspondant son NIP d entr e personnelle non le dernier NIP temporaire puis enfoncer et tenir le bouton sk L clairage de l ouvre porte clignotera trois fois Rel cher le bouton Un bouton ferm L ouvreur peut tre ferm en appuyant sur le bouton
104. le message n est pas effac apr s les v rifications ci dessus se reporter au message n 2 Bee e Signification Ce message appara t si le c blage des d tecteurs d inversion de s curit est ANOMALIE DE erron Pour effacer le message effectuer les op rations suivantes FONCTIONNEMENT DES Inspecter les fils des d tecteurs d inversion de s curit pour d tecter un court circuit agrafe DETECTEURS DE SECURITE dans le fil corriger la polarit des branchements fils noir blanc invers s remplacer relier V RIFIER LE C BLAGE VOIR si n cessaire MANUEL DU PROPRIETAIRE D connecter tous les fils de la plaque arri re du moteur Retirer les d tecteurs d inversion de s curit de leurs supports et raccourcir les fils des d tecteurs une longueur de 1 2 pieds 30 60 cm partir de l arri re de chaque d tecteur Rattacher la cellule de transmission au moteur l aide des fils raccourcis Si le t moin lumineux de la cellule de transmission brille de mani re constante fixer la cellule de r ception Aligner les d tecteurs si les t moins lumineux sont allum s remplacer les fils des d tecteurs Si les t moins lumineux de d tection ne s allument pas remplacer les d tecteurs d inversion de s curit Message Se e Signification Ce message appara t lorsque le bouton Prog LEARN a t appuy sur la RECONNAISSANCE DE LA commande de porte Appuyer de nouveau sur le bouton Prog LEARN permet l utilisateur
105. liser les trous sup rieurs et inf rieurs ou lat raux de support de porte Percer des trous de 5 16 po travers la porte et fixer le support l aide de boulons t te bomb e et collet carr de 5 16 po x 2 po des rondelles de blocage et des crous non fournis Figure 4 REMARQUE Les vis autotaraudeuses de 1 4 po 14 x 5 8 po ne sont pas pr vues pour tre utilis es sur des portes en bois GRANDEUR R ELLE DES FIXATIONS Vis autotaraudeuse 1 4 de po 14 x 5 8 de po ATTENTION Les portes de garage en fibre de verre en aluminium ou en acier l ger ont BESOIN d tre renforc es AVANT la fixation du support de porte Il est conseill de s adresser au fabricant de la porte pour obtenir un n cessaire de renforts Support de linteau JE Situation pr EE du support p SSS de porte i US DES RENFORTS D HORIZONTAUX ET VERTICAUX Ligne du vl SONT REQUIS DANS LE CAS centre vertical D UNE PORTE DE GARAGE de la porte de L G RE EN FIBRE DE VERRE garage EN ALUMINIUM EN ACIER EN PANNEAUX DE VERRE ETC rs NON FOURNIS Figure 1 Renforts verticaux Ligne du Cl centre SN o vertical de AN d o o la porte s de garage Mo ofo Ligne du centre vertical de la porte de garage Renforts verticaux Support de la porte Rondelle de blocage T de 5 16 de po x Ecrou de 5 16 de po 18 Vis autotaraudeuse 1 4 de po 14 x 5
106. ludes hardware listed on page 7 114A4328 Owner s manual 40 Motor Unit Assembly Parts KEY PART KEY PART NO NO DESCRIPTION NO NO DESCRIPTION 41C76 Belt cap and sprocket 7 41A6231 End panel with battery door 41B4245 Line cord and screw 41B4375 3 Terminal block with screws 8 410190 Transformer and harness 41A6281 Wire harness kit 41D504 6 Cover Complete with Battery wires 108D79 Light lens and plug light socket wires 175B88 Light socket and plug RPM passpoint wires with plug 41D794 Motor with travel module 41DB002 2 Receiver logic assembly NOT SHOWN 41A6357 1 Battery kit 41 ACCESSORIES 7702C Outside Quick Release Required for a garage with NO access door 8 Foot 2 4 m Rail Extension To allow an 8 foot 2 4 m door to open fully 10 Foot 3 m Rail Extension To allow a 10 foot 3 m door to open fully Extension Brackets Optional For safety reversing sensor installation onto the wall or floor To order call 1 800 528 9131 Remote Light Control Enables homeowner to turn on a lamp television or other appliance from their car with their garage door opener remote or from anywhere in their home with an additional Chamberlain Security remote 42 CLDM1C 41A6345 1 SECURITY 3 Button Remote Control Includes visor clip SECURITY 3 Button Mini Remote Control With key ring and fastening strip SECURITY AS Keyless Entry
107. lustr Introduire un anneau d arr t pour immobiliser Anneau d arr t Trou de montage Boite d emballage ou support temporaire BSD III IIS II IS IS LLL LLL LLL GRANDEUR R ELLE DES FIXATIONS Axe de chape de 5 16 de po x 1 1 2 po Anneau d arr t 14 POSE 4 OP RATION Positionnement de l ouvre porte Suivre les instructions qui se rapportent la porte de garage particuli re en se rapportant aux illustrations PORTE ARTICUL E OU PORTE RIGIDE AVEC GUIDES Un 2 x 4 pos plat convient tr s bien pour obtenir l espace qu il faut entre la porte et le rail Enlever l emballage en mousse e Lever l ouvre porte et le faire reposer sur un escabeau Si l escabeau n est pas assez haut demander de l aide e Ouvrir compl tement la porte et mettre un 2 x 4 plat sur sa partie sup rieure sous le rail Sile panneau ou la section du dessus vient en contact avec le chariot lorsqu on l ve la porte tirer sur la biellette de d gagement du chariot pour d gager le chariot int rieur du chariot ext rieur Faire glisser le chariot ext rieur vers le moteur II ne sera pas n cessaire de r assembler le chariot avant la fin de l op ration 12 F 1 Cer FU J Co N Biellette de L J d gagement du chariot ENGAG D GAG PORTE RIGIDE SANS GUIDES Poser un 2 x 4 sur le c t pour obtenir l espace qu il faut entre la porte et le rail Enlev
108. moteur les bornes orient es vers l ext rieur e Brancher les fils rouge et noir du moteur sur les bornes correspondantes de la batterie e V rifiez que les fils de la batterie soient bien install s dans le conduit e Remettre le couvercle de la batterie en place POSE 8 OP RATION Pose des ampoules e Appuyer sur les pattes de d gagement des deux c t s du diffuseur Faire pivoter le diffuseur d licatement vers l arri re et le bas jusqu ce que la charni re du diffuseur soit compl tement ouverte Ne pas retirer le diffuseur Visser une ampoule de 100 watts maximum dans chaque douille La taille l g re d ampoule doit tre A19 cou standard seulement Les lumi res s allumeront et resteront allum es pendant environ 4 1 2 minutes aussit t que le courant sera tabli Les lumi res s teindront ensuite e Inverser la proc dure pour fermer le diffuseur Pour remplacement utilisez les lampes lectriques standard A19 pour ouvre porte de garage REMARQUE Utiliser uniquement des ampoules standard L utilisation d ampoules col court ou d ampoules sp cialis es peut causer une surchauffe du panneau d extr mit ou de la douille ATTENTION Munissez vous TOUJOURS de gants de protection et de protection pour les yeux quand vous travaillez sur une pile lectrique ou sur un compartiment de batterie Couvercle de la batterie Batterie ATTENTION Pour vit
109. n MUST be made by a trained door systems technician ALWAYS disconnect electric power to garage door opener BEFORE making ANY repairs or removing covers SAVE THESE INSTRUCTIONS 5 If obstructed while closing the door will reverse If the obstruction interrupts the sensor beam the opener lights will blink for five seconds 6 If obstructed while opening the door will stop 7 If fully open the door will not close when the beam is broken The sensor has no effect in the opening cycle If the sensor is not installed or is misaligned the door won t close from a hand held remote However you can close the door with the Door Control the Outside Keylock or Keyless Entry if you activate them until down travel is complete f you release them too soon the door will reverse The opener lights will turn on under the following conditions when the opener is initially plugged in when power is restored after interruption when the opener is activated They will turn off automatically after 4 1 2 minutes or provide constant light when the Light feature on the Smart Control Panel is activated Bulb size is A19 Bulb power is 100 watts maximum Security light feature Lights will also turn on when someone walks through the open garage door With a Smart Control Panel this feature may be turned off as follows With the opener lights off press and hold the light button for 10 seconds until the light goes on then off
110. n form en syst mes de garage est quilibr e et qu elle ne force pas porte si la porte de garage force ou est d s quilibr e Une 1 Soulever la porte moiti comme illustr puis la porte de garage d s quilibr e peut NE PAS remonter au rel cher Si elle est quilibr e elle devrait rester en besoin place enti rement support e par ses ressorts Ne JAMAIS tenter de desserrer d placer ou r gler la 2 Faire monter et descendre la porte pour s assurer qu elle porte de garage ainsi que les ressorts cables poulies ne force pas supports de porte ou leurs ferrures de montage lesquels sont tous sous une tension EXTR ME D sactiver TOUTES les serrures et retirer TOUTES les cordes raccord es la porte de garage AVANT de poser et d utiliser l ouvre porte de garage afin d viter un emm lement Si votre porte force ou est d s quilibr e appeler un technicien form en syst mes de porte ATTENTION Pour pr venir les dommages la porte de garage et l ouvre porte TOUJOURS d sactiver les serrures AVANT de poser et d utiliser l ouvre porte Faire fonctionner l ouvre porte de garage UNIQUEMENT une tension de 120 V 60 Hz pour viter les d fauts de fonctionnement et les dommages CTI g Porte articul e Porte rigide Outils n cessaires Lors de l assemblage de la pose et du r glage de l ouvre porte les i
111. n tournevis dans l une des fentes pour bague et le tenir contre le chariot Placer une cl ouverte de 7 16 de pouce sur l extr mit carr e Tourner environ 1 4 de tour jusqu ce que le ressort se d gage et enclenche la bague contre le chariot Ceci tend le ressort pour une tension optimale de la courroie Le montage de l ouvre porte de garage est maintenant termin Lire les avertissements suivants avant de proc der la section sur la pose Chariot Extr mit carr e Bague Bague AVANT l 1 po APRES 2 5 cm L ENCLENCHEMENT 1 1 4 de po 3 18 cm POSE IMPORTANTES INSTRUCTIONS CONCERNANT LA POSE AVERTISSEMENT Pour r duire le risque de BLESSURES GRAVES ou MORTELLES LIRE ET SUIVRE TOUS LES AVERTISSEMENTS ET 8 Ne JAMAIS porter de montres bagues ou v tements INSTRUCTIONS DE POSE amples durant la pose ou l entretien de l ouvre porte Poser l ouvre porte de garage UNIQUEMENT sur une Ils pourraient tre happ s par la porte de garage ou les porte de garage bien quilibr e et lubrifi e Une porte mal m canismes de l ouvre porte quilibr e peut NE PAS remonter au besoin et pourrait Poser la commande de porte de garage provoquer des BLESSURES GRAVES ou LA MORT en vue de la porte de garage TOUTES les r parations aux c bles ensembles de ressort e hors de la port e des enfants une hauteur minimum et autres ferrures de montage DOIVENT tre confi es de 5 pieds 1
112. ndant vous pouvez fermer la porte avec la commande de porte fa cl de verrouillage ext rieur ou l entr e sans cl si vous les activez jusqu ce que la fermeture soit compl te Si vous les rel chez trop t t la porte s inversera L clairage de l ouvre porte de garage s allumera dans les cas suivants lorsque l on branche l ouvre porte de garage pour la premi re fois sur le courant lorsque le courant est interrompu lorsque l ouvre porte est actionn Cet clairage s teint automatiquement apr s 4 1 2 minutes ou il assure un clairage constant lorsqu on actionne la fonction d clairage sur la Smart Control Panel La taille d ampoule est A19 Le pouvoir d ampoule est 100 maximum de watts Eclairage Security Les lumi res s allumeront galement lorsqu une personne franchira la porte de garage ouverte Sur la Smart Control Panel cette fonction d clairage peut tre d sactiv e de la fa on suivante les lumi res ferm es enfoncer et tenir le bouton d clairage pendant 10 secondes jusqu ce que les lumi res s teignent puis s allument de nouveau Pour r tablir cette fonction commencer avec le dispositif d clairage de l ouvre porte allum puis enfoncer et tenir le bouton d clairage pendant 10 secondes jusqu ce que les lumi res 31 s teignent puis s allument nouveau Utilisation de la commande de porte SMART CONTROL PANEL D tecteur de mouvement Bee activ e d sacti
113. ng on battery power and that the battery charge is low e To test the battery is functioning properly open and close the garage door e Re connect the motor unit power cord back into the electrical outlet Verify that the green LED is flashing on the BBU indicates that the battery is now charging Test completed 2 Charge the battery e Battery will take 24 to 48 hours to fully charge A fully charged battery supplies 12 Vdc to the motor unit for one to two days of normal operation during an electrical power outage If the battery voltage drops too low the batteries will disconnect and the motor unit will no longer operate under battery power After the electrical power has been restored the battery will recharge within 48 hours Under normal usage batteries will last 3 to 5 years To obtain maximum battery life and prevent damage disconnect the battery when motor unit is unplugged for an extended period of time NOTE Door operation may be limited until battery is fully charged The motor unit s lights will not turn on during battery mode 33 WARNING To reduce the risk of FIRE or INJURY to persons Disconnect ALL electric and battery power BEFORE performing ANY service or maintenance Use ONLY Chamberlain part 41A6357 1 for replacement battery DO NOT dispose of battery in fire Battery may explode Check with local codes for disposal instructions CAUTION ALWAYS wear protective gl
114. notent Le d tecteur inverseur de s curit doit tre raccord et align correctement avant que l ouvre porte de garage n entame la proc dure de fermeture V rifier que les d tecteurs inverseurs de s curit sont bien install s et d pourvus d obstruction Se reporter la 11 tape de pose Pose du Syst me Protector V rifier le diagnostic du voyant DEL concernant les clairs sur le moteur puis se reporter la Fiche diagnostic la page suivante Mes t l commandes ne font pas fonctionner la porte V rifier que votre commande murale de luxe ne clignote pas Si elle clignote d sactiver le mode de verrouillage en suivant les instructions du passage consacr Utilisation de la commande de porte murale e Reprogrammer les t l commandes en suivant les instructions de programmation Se reporter au chapitre Programmation Silat l commande ne fait toujours pas fonctionner votre porte examiner le voyant DEL diagnostique et observer le cas ch ant les clairs sur le moteur puis se reporter la Fiche diagnostic la page suivante La porte inverse sa course sans raison apparente Apr s avoir proc d au r glage de la force ou des limites de course r p ter le contr le de l inversion de s curit Le besoin de proc der des r glages occasionnels des limites de courses et de la force est normal Les variations saisonni res en particulier peuvent alt rer la course de la porte
115. nstructions feront appel aux outils main illustr s ci apr s Crayon Scie m taux o gt 20 gt Marteau Pince coupante Forets de 3 16 de po Ee 5 16 de po et 5 32 de po Tournevis Pince universelle Cl molette Cl douille et douilles de 1 2 de po 7 16 de po 9 16 de po et 1 4 de po Planification Identifier le type et la hauteur de votre porte de garage H Examiner la r gion du garage pour noter si l une des conditions ci apr s s applique votre installation Des mat riaux suppl mentaires peuvent amp tre n cessaires Il vous sera peut tre utile de vous reporter cette page et aux illustrations qui l accompagnent en proc dant la pose de l ouvre porte Suivant les exigences particuli res il faudra pour plusieurs op rations de pose des mat riaux et ou des fixations qui ne sont pas fournis e 1 op ration de pose Concerne le mur ou le plafond au dessus de la porte de garage Le crochet de linteau doit tre assur ment attach aux soutiens structuraux e 5 op ration de pose Le plafond du garage est il fini Dans l affirmative une corni re et des fixations suppl mentaires seront requises 11 op ration de pose Suivant la construction du garage des supports de rallonge ou des blocs en bois peuvent tre n cessaires pour poser les capteurs e 11 op ration de montage Le montage alternatif au sol du d tecteur inverseur de s curit n cessiter
116. nt bloqu es en place 5 Ins rer l arbre filet du chariot travers le trou du chariot Faites bien s r que la courroie ne soit pas emm l e 6 Tenir la courroie au niveau de l arbre du chariot tout en vissant l crou ressort la main sur l arbre jusqu ce qu il soit serr contre le chariot V UTILISER aucun outil 7 Retirer le tournevis 8 Positionner le capuchon de retenue de la courroie par dessus le poulie de l ouvre porte comme illustr et fixer la plaque de montage l aide des vis hexagonaux de 8 x 3 8 po fournis Poulie crou de chariot ressort 10 AVERTISSEMENT Pour viter d ventuelles BLESSURES GRAVES aux doigts par suite du mouvement de l ouvre porte TOUJOURS garder la main l cart de la poulie courroie lorsque l ouvre porte fonctionne Attacher fermement le rev tement c t tambour de la poulie courroie AVANT utilisation GRANDEUR R ELLE DES FIXATIONS STI Vis hexagonal de 8 x 3 8 de po crou de chariot ressort Ressort pince du maillon de raccord x Chapeau du maillon de raccord Mid de cheville Arbre Barre du filet du maillon de chariot raccord Trou Connecteur de chariot Vis hexagonal de 8x 3 8 de po SX Capuchon de retenue de la courroie Poulie courroie du moteur Plaque de montage MONTAGE 5 OP RATION R gler la tension e Ins rer le bout d u
117. ntory Your garage door opener is packaged in one carton which contains the motor unit and all parts illustrated below Accessories will depend on the model purchased If anything is missing carefully check the packing material The Protector System 2 Safety Reversing Sensors Sending Eye and 1 Receiving Eye with 2 Conductor White amp White Black Bell Wire attached Door Bracket Q 9 9 9 ef o 9 o Hanging Brackets U Bracket Curved Door Arm Section Straight Door Arm Section ur Idler Pulley D I Rail Front header Section Garage Door Monitor Model 547445 Only Safety Reversing Sensor Bracket 2 Remote Light Control Parts may be stuck in the foam Hardware for assembly and installation is shown on the next page Save the carton and packing material until installation and adjustment is complete QD Belt Cap Retainer CH 2 Conductor Bell Wire White amp White Red Safety Labels and Literature Header Bracket Rail Center Back Sections Smart Control Panel A SECURITY Keyless Entry AS SECURITY 3 Button Remote Control 2 SECURITY 3 Button Mini Remote Control 1 Model 547445 Only Surge Protector Park Assist Model 547445 Only Model 547445 Only Hardware Inventory Separate all hardware and group as shown below for the assembly and installation procedures ASSEMBLY HARDWARE ei OG OH Spring Trolley Nut 1
118. ode d inactivit prolong e Ouverture manuelle de la porte AVERTISSEMENT LA PILE DE LA T L COMMANDE AVERTISSEMENT Pour pr venir d ventuelles BLESSURES GRAVES ou LA MORT par suite de la chute d une porte de garage Si possible utiliser la poign e de d clenchement d urgence pour d gager le chariot UNIQUEMENT lorsque la porte de garage est FERMEE Des ressorts faibles ou bris s ou une porte d s quilibr e peuvent causer la chute rapide et ou impr vue d une porte ouverte Ne JAMAIS utiliser la poign e de d clenchement d urgence moins que l entr e de garage ne soit d gag e absence de personnes et d obstacles Ne JAMAIS utiliser la poign e pour ouvrir ou fermer la porte Il y a risque de chute si le n ud de la corde se d fait Chariot Kb POUR D GAGER LE CHARIOT Dans la mesure du possible la porte doit tre compl tement ferm e Tirer la poign e de d clenchement d urgence vers le bas de facon que la biellette de d gagement du chariot s enclenche dans une position verticale et lever la porte manuellement La fonction de verrouillage emp che le chariot de se r enclencher automatiquement Il sera alors possible d ouvrir et de fermer la porte la main autant de fois qu on le d sirera Pour rattacher la porte l ouvre porte appuyer sur le gros bouton poussoir de la commande de porte Biellette de d gagement du chariot en position de d gagem
119. on a second time and the display will show Learn Mode Press Remote Control Button to Learn Remote Press the button of the remote control to be learned and the worklight will blink to confirm the remote control has been learned Hour amp Minute Feature Press or hold either of these side buttons to increment the hour or minute displayed on the LCD display T w Lang Language Feature Press this side button to toggle between the three languages English Spanish and French Degrees F C Feature Press this side button to toggle the temperature units between Fahrenheit and Celsius Additional feature when used with the 3 Button hand held remote To control the opener lights In addition to operating the door you may program the remote to operate the lights 1 With the door closed press and hold a small remote button that you want to control the light 2 Press and hold the Light button on the door control 3 While holding the Light button press and hold the Lock button on the door control 4 After the opener lights flash release all buttons Standby Power Unit Optional OPERATING INSTRUCTIONS 1 Test the installed battery with the motor unit To test the battery disconnect the motor unit power cord from the electrical outlet Asolid orange LED indicates the battery is operating on battery power e Aflashing orange LED with beep indicates the unit is operati
120. or remote controls Activate door ONLY when it can be seen clearly is properly adjusted and there are no obstructions to door travel ALWAYS keep garage door in sight until completely closed NEVER permit anyone to cross path of closing garage door Outside Keylock Accessory Connections To opener quick connect terminals white to white white red to red HARDWARE SHOWN ACTUAL SIZE NN Screw 6ABx1 1 4 standard installation Screw 6 32x1 pre wired Insulated Staples Drywall Anchors Figure 1 REMOVE amp REPLACE COVER To Replace Insert Top Tabs Pret FS Figure 2 PRE WIRED INSTALLATION 24 Volt Bell Wire To insert or release wire push f Nin tab with screwdriver tip Red White Grey INSTALLATION STEP 7 Install the Battery Make sure motor unit is unplugged Using a Phillips head screwdriver remove the battery cover on the motor unit Partially insert battery into motor unit with terminals facing out Connect the red 4 and black wires from motor unit to corresponding terminals on battery Verify the battery wires are seated in the channel Replace battery cover INSTALLATION STEP 8 Install the Lights Press the release tabs on both sides of lens Gently rotate lens back and downward until the lens hinge is in the fully open position Do not r
121. otector 20 23 Fixation du support de la porte 24 25 Fixation de la biellette de la porte au chariot 26 27 INTRODUCTION Revue des symboles de s curit et des mots de signalement R glages 28 30 Programmation des limites de la course 28 R glage de sensibilit 29 Contr le du syst me d inversion de s curit 30 Essai du Syst me Protector 30 Fonctionnement 31 37 Instructions de fonctionnement en toute s curit 31 Utilisation de votre ouvre porte 31 Utilisation de la commande de porte 32 De courant d alimentation en attente CAA 33 Entretien de votre ouvre porte 34 Ouverture manuelle de la porte 34 D fauts de fonctionnement D pannage 35 Fiche diagnostique 36 Message de Smart Control Panel 37 Programmation 38 39 Pour ajouter ou reprogrammer une t l commande main suppl mentaire 38 Pour effacer tous les codes de la m moire du moteur 38 T l commandes trois boutons 38 Pour ajouter reprogrammer ou modifier un NIP d entr e sans cl 39 Pi ces de r paration 40 41 Pi ces d assemblage du rail 40 Pi
122. oves and eye protection when changing the battery or working around the battery compartment O O O 00 L EI M U Ug Battery Status LED g NOTE LED is most visible with worklight off GREEN LED All systems are normal Asolid LED light indicates the battery is fully charged Aflashing LED indicates the battery is being charged NOTE Battery does not have to be fully charged to operate the motor unit ORANGE LED The motor unit has lost power and is operating off of the battery A solid LED with beep sounding approximately every 2 seconds indicates the motor unit is activating the door and is operating off of the battery A flashing LED with beep sounding every 30 seconds indicates battery is low e Once the power is restored the battery will recharge This is indicated by a flashing green LED e RED LED If a red LED remains on when the power is restored and is accompanied by a beep sounding every 30 seconds replace the battery To obtain maximum battery life and prevent damage also disconnect the battery if you unplug the motor unit while on vacation or any other extended period of time e To Open the Door Manually WARNING THE REMOTE CONTROL BATTERY 4 amp WARNING To prevent possible SERIOUS INJURY or DEATH from a falling garage door If possible
123. properly See Adjustment Step 3 Floor or door should be repaired SECTIONAL DOOR INSTALLATIONS Do you have a steel aluminum fiberglass or glass panel door If so horizontal and vertical reinforcement is required Installation Step 12 The opener should be installed above the center of the door If there is a torsion spring or center bearing plate in the way of the header bracket it may be installed within 4 feet 1 2 m to the left or right of the door center See Installation Steps 1 and 12 If your door is more than 7 feet 2 1 m high see rail extension kits listed on Accessories page FINISHED CEILING Cs Support bracket amp WW WW H fastening hardware H is required d See page 16 S Motor unit Ge Wall mounted Door Control Access Door Header Trolley CLOSED POSITION Bracket Stop Bolt Trolley Safety bottom of door must not Sensor exceed 1 4 6 mm Safety Reversing Sensor Gap between floor and Reversing Emergency Release Rope Garage Door Bracket Door Arm Planning Continued ONE PIECE DOOR INSTALLATIONS A WARNING Generally a one piece door does not require Without a properly working safety reversal system reinforcement If your door is lightweight refer to the persons particularly small children could be information relating to sec
124. push in tab with screwdriver tip Red White Grey Quick Connect Terminals TROUBLESHOOTING THE SAFETY REVERSING SENSORS 1 If the sending eye indicator light does not glow steadily after installation check for Electric power to the opener Ashort in the white or white black wires These can occur at staples or at opener connections Incorrect wiring between sensors and opener Abroken wire 2 If the sending eye indicator light glows steadily but the receiving eye indicator light doesn t Check alignment Check for an open wire to the receiving eye 3 If the receiving eye indicator light is dim realign either sensor NOTE When the invisible beam path is obstructed or misaligned while the door is closing the door will reverse If the door is already open it will not close The opener lights will blink 10 times See page 20 INSTALLATION STEP 12 Fasten the Door Bracket Follow instructions which apply to your door type as illustrated below or on the following page A horizontal reinforcement brace should be long enough to be secured to two or three vertical supports A vertical reinforcement brace should cover the height of the top panel Figure 1 shows one piece of angle iron as the horizontal brace For the vertical brace 2 pieces of angle iron are used to create a U shaped support The best solution is to check with your garage door manufacturer for an opener installation door reinforcement kit
125. r at a minimum height of 5 feet 1 5 m where small children cannot reach away from moving parts of door and door hardware If installing into drywall drill 5 32 holes and use the anchors provided For pre wired installations as in new home construction it may be mounted to a single gang box Figure 2 NOTE The functional temperature range of the door control is between 4 F 20 C and 122 F 50 C Scroll speed of display is slower at lower temperatures although the door control remains fully functional CAUTION Continuous exposure of the door control to temperatures below 22 F 30 C may damage the LCD Screen 1 Strip 7 16 11 mm of insulation from one end of bell wire and connect to the two screw terminals on back of door control by color white wire to W 2 and white red wire to the R 1 2 Remove cover by gently prying at slot in top of the cover with a small flat head screwdriver Fasten with 6ABx1 1 4 self tapping screws drywall installation or 6 32x1 machine screws into gang box as follows Install bottom screw allowing 1 8 3 mm to protrude above wall surface Position bottom of door control on screw head and slide down to secure Adjust screw for snug fit Drill and install top screw with care to avoid cracking plastic housing DO NOT overtighten Insert top tabs and snap on cover 3 For standard installation only Run bell wire up wall and across ceiling to motor unit Use insula
126. r opener e Strip 7 16 11 mm of insulation from each set of wires Separate white and white black wires sufficiently to connect to the opener quick connect terminals Twist like colored wires together Insert wires into quick connect holes white to white and white black to grey Figure 10 Figure 10 Bell Wire Finished Ceiling Wy m Sensor Invisible Light Beam Safety Reversing Sensor Protection Area ALIGNING THE SAFETY REVERSING SENSORS Plug in the opener The indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct The sending eye amber indicator light will glow regardless of alignment or obstruction If the green indicator light in the receiving eye is off dim or flickering and the invisible light beam path is not obstructed alignment is required Loosen the sending eye wing nut and readjust aiming directly at the receiving eye Lock in place Loosen the receiving eye wing nut and adjust sensor until it receives the sender s beam When the green indicator light glows steadily tighten the wing nut 23 Connect Wire to Quick Connect Terminals Safety Reversing 7 16 11 mm EE NENNEN 1 Strip wire 7 16 11 mm 2 Twist like colored wires together 3 To insert or release wire
127. racket Fasten Wood Block to Wall with Lag Screws not provided Accessories or wood blocks can be used SE racke Use bracket mounting holes as a template to locate and drill 2 3 16 diameter pilot holes on the wall at each side of the door no higher than 6 15 cm above the Lag Screws __ not provided floor Attach brackets to wall with lag screws not provided e f using extension brackets or wood blocks adjust right and left assemblies to the same distance out from Figure 3 WALL MOUNT RIGHT SIDE the mounting surface Make sure all door hardware obstructions are cleared Floor installation Figure 4 Use wood blocks or extension brackets see Accessories to elevate sensor brackets so the lenses will be no higher than 6 15 cm above the floor e Carefully measure and place right and left assemblies at the same distance out from the wall Be sure all door hardware obstructions are cleared Lens Extension Bracket See Accessories Provided with Extension Bracket Fasten to the floor with concrete anchors as shown Sensor HARDWARE SHOWN ACTUAL SIZE Bracket Provided with Lens e Extension Bracket Indicator HD in Figure 4 FLOOR MOUNT RIGHT SIDE Carriage Bolt Wing Nut Staples 1 4 20x1 2 1 4 20 H Attach with Concrete Anchors not provided Indicator Light Sensor Bracket 21 MOUNTING AND WIRING THE SAFETY Figure
128. rage de travail Voir fonction d clairage automatique ci dessous LIGHT Fonction de verrouillage La fonction de verrouillage est con ue de mani re emp cher le fonctionnement de la porte l aide LOCK de t l commandes main Cependant la porte s ouvrira et se fermera partir de la commande de porte de interrupteur cl ext rieur ou du syst me d entr e sans cl en accessoire Pour actionner appuyer sur le bouton de verrouillage et le tenir pendant 2 secondes Pour arr ter appuyer nouveau sur le bouton de verrouillage et le tenir pendant 2 secondes La fonction de verrouillage sera galement neutralis e chaque fois que le bouton learn se trouvant sur le panneau de l ouvre porte sera actionn Fonctionnalit de l clairage du d tecteur de mouvement L clairage de l ouvre porte s active automatiquement lorsqu une personne passe devant la commande de porte murale Cette fonctionnalit est activ e par la d tection du mouvement et de la chaleur du corps humain L clairage de l ouvre porte fonctionnera pendant cinq minutes puis s arr tera si aucun mouvement suppl mentaire ou si aucun diff rentiel de chaleur n est d tect Pour d sactiver cette fonctionnalit appuyer sur le bouton ON OFF marche arr t d clairage automatique sur le c t gauche de la commande de porte Il est recommand de d sactiver le d tecteur de mouvement en CG cas d usage de l cl
129. repair to or adjustment of the opener ADJUSTMENT STEP 4 Test The Protector System Press the remote control push button to open the door Place the opener carton in the path of the door e Press the remote control push button to close the door The door will not move more than 1 2 5 cm and the opener lights will flash The garage door opener will not close from a remote if the indicator light in either sensor is off alerting you to the fact that the sensor is misaligned or obstructed If the opener closes the door when the safety reversing sensor is obstructed and the sensors are no more than 6 15 cm above the floor call for a trained door systems technician 30 WARNING Without a properly installed safety reversal system persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door Safety reversal system MUST be tested every month After ANY adjustments are made the safety reversal system MUST be tested Door MUST reverse on contact with 1 1 2 high 3 8 cm object or 2x4 laid flat on the floor 1 1 1 2 3 8 cm board or a 2x4 laid flat 4 amp WARNING Without a properly installed safety reversing sensor persons particularly small children could be SERIOUSLY INJURED or KILLED by a closing garage door
130. risque d incendie d explosion ou de br lure chimique Remplacer les piles UNIQUEMENT par des piles capsules 3V2032 NE PAS recharger ni d monter ni chauffer une temp rature sup rieure 100 C 212 F ni incin rer La pile au lithium devrait durer pendant une p riode allant jusqu 5 ans Pour changer la pile ouvrir le boitier comme illustr en le soulevant l aide de la pince du pare soleil ou de la lame d un tournevis Ins rer la pile avec le c t positif vers le haut Se d barrasser de la pile usag e convenablement Remplacer les piles UNIQUEMENT par des piles capsules 3V2032 Pile au p le positif vers 9 AVIS Les r gles de la FCC ou d Industrie Canada IC ou les deux interdisent tout ajustement ou toute modification de ce r cepteur et ou de cet metteur sauf pour modifier le code ou pour remplacer la pile IL N EXISTE AUCUNE AUTRE PIECE SUSCEPTIBLE D ETRE ENTRETENUE PAR L UTILISATEUR V rifi pour conformit avec les normes de la FCC POUR UTILISATION A LA MAISON OU AU BUREAU L utilisation est sujette aux deux conditions ci apr s 1 ce dispositif ne peut causer des interf rences nuisibles et 2 ce dispositif doit accepter toute interf rence recue y compris une interf rence pouvant causer un fonctionnement non d sir D fauts de fonctionnement D pannage 1 Ma porte ne se ferme pas et les ampoules de l clairage du moteur clig
131. rmeture Voir Figure 3 de la page 26 R p ter l essai Lorsque la porte remonte sur la planche de 1 1 2 po 3 8 cm d paisseur ou un 2 x 4 plat retirer l obstacle et faire faire 3 ou 4 cycles complets l ouvre porte afin de v rifier le r glage Si l essai du Syst me d inversion de S curit choue appeler un technicien form en syst mes de porte V RIFICATION DE S CURIT IMPORTANTE Faire l essai du Syst me d inversion de S curit apr s Chaque fois que l on modifie la longueur des biellettes et chaque fois que l on proc de un r glage de la force et de la course de la porte Chaque fois que l on r pare ou que l on r gle la porte du garage y compris les ressorts et les fixations Chaque fois que l on r pare le plancher du garage ou apr s un soul vement de celui ci Chaque fois que l on proc de une r paration ou un r glage de l ouvre porte R GLAGES 4 OP RATION Essai du Syst me Protector Appuyer sur le bouton poussoir de la t l commande pour ouvrir la porte Mettre la bo te en carton de l ouvre porte dans la course de la porte Appuyer sur le bouton poussoir de la t l commande pour fermer la porte La porte ne se d placera pas de plus d un pouce 2 5 cm et les lumi res de l ouvre porte clignoteront La porte de garage ne se fermera pas l aide d une t l commande si le t moin lumineux d un des deux d tecteurs est teint ce qui avertit que le d tecteur
132. s curit de mani re ce que le faisceau NE SOIT PAS A UNE HAUTEUR de plus de 6 po 15 cm au dessus du plancher du garage Si les unit s doivent tre mont es sur le mur les supports doivent tre fix s fermement une surface solide telle que la charpente du mur On peut se procurer des supports de rallonge se reporter la section accessoires au besoin Si la pose se fait dans une construction en ma onnerie ajouter un morceau de bois chaque endroit pour viter de percer des trous suppl mentaires dans la ma onnerie si un repositionnement est n cessaire I ne doit y avoir aucun obstacle sur le parcours du faisceau de lumi re invisible Aucune partie de la porte de garage ni les guides les ressorts les charni res les rouleaux ou autres fixations de la porte ne doit interrompre le faisceau pendant que la porte se ferme D gp lt D D T ae HT D tecteur inverseur de s curit 6 po 15 cm max au dessus du sol Zone de protection du faisceau lumineux invisible Faisant face la porte depuis l int rieur du garage GN D tecteur inverseur de s curit 6 po 15 cm max au dessus du sol POSE DES SUPPORTS S assurer que l ouvre porte est hors tension Poser et aligner les supports de mani re ce q
133. s a temporary stop insert a screwdriver into the hole packaged inside the front rail and set aside for 10 25 cm from the front end of the rail as shown Installation Step 5 and 12 NOTE To prevent INJURY 5 Check to be sure there are 4 plastic wear pads inside while unpacking the rail carefully remove the straight the inner trolley If they became loose during shipping door arm stored within the rail section check all packing material Snap them back into 2 Align the rail sections on a flat surface as shown and position as shown slide the tapered ends into the larger ones Tabs along 6 Slide the trolley assembly along the rail from the back the side will lock into place end to the screwdriver KEEP LARGER HOLE ON TOP FRONT RAIL TOP Tapered End Tapered fl Screwdriver EZ i 5 di abs Window Cut Out Front Rail Idler Pulley TO DOOR Wear Pads ASSEMBLY STEP 2 Fasten the Rail to the Motor Unit e Insert a 1 4 20x1 3 4 bolt into the cover protection bolt hole on the back end of the rail as shown Tighten securely with a 1 4 20 lock nut DO NOT overtighten Remove the two bolts from the top of the motor unit Place the U bracket flat side down on the motor unit and align the bracket holes with the bolt holes Fasten with the previously removed bolts Align the rail assembly with the top of the motor unit Slide the rail end onto the U bracket al the way to the stops
134. s en cons quence LORSQUE VOUS COMMANDEZ DES PI CES DE RECHANGE DONNEZ TOUJOURS LES RENSEIGNEMENTS SUIVANTS e NUM RO DE LA PI CE e NOM DE LA PI CE e NUMERO DE MOD LE PASSEZ VOS COMMANDES THE CHAMBERLAIN GROUP INC Technical Support Group 6050 S Country Club Road Tucson Arizona 85706 NOTRE NUM RO DE SERVICE 1 800 528 9131 1 800 528 9131 www chamberlain com Pour une installation des pi ces et un service professionnels communiquez avec votre d positaire local CHAMBERLAIN Recherchez son num ro dans les pages jaunes ou appelez notre num ro de service Vous obtiendrez la liste des concessionnaires de votre r gion _ GARANTIE LIMIT E DE TROIS ANS DE CHAMBERLAIN GARANTIE LIMIT E A DIES ANS POUR LE COURROLE ET GARANTIE LIMIT E A VIE SUR LE MOTEUR La soci t Chamberlain Group Inc le Vendeur garantit l acheteur au d tail initial de ce produit dans la r sidence duquel ce produit est originalement install que le produit est exempt de tout d faut de mati re ou vice de fabrication pour une p riode de trois ans compter de la date d achat et que et courrole est exempt de d faut de mati re et ou vice de fabrication pour une p riode de dies ans et le moteur est exempt d faut de mati re et ou vice defabrication pour le vie de produit Pour que ce produit fonctionne correctement il faut se conformer aux instructions relatives l installation l op ration la maintenance et a
135. should not have a backward slant when fully open as illustrated below A slight backward slant will cause unnecessary bucking and or jerking operation as the door is being opened or closed from the fully open position Figure 6 Figure 6 Inner Trolley Outer Trolley Closed Door Inner Trolley Open Door Emergency Release Handle Figure 5 CORRECT INCORRECT Groove facing out Ya Door Bracket Q9 Ring Fastener Lock Nuts Washers 5 16 18 Clevis Pin Straight 5 16 x1 1 4 Arm Bolts 5 16 18x7 8 Curved Door Arm RE Trolley Correct Angle T2 The 2 gt Door with Backward Slant Incorrect ADJUSTMENT STEP 1 Program the Travel Limits Travel limits regulate the points at which the door will stop when moving up or down Figure 1 Oo0o 00 LED Black Button 2 os f er Purple CO Button Adjust the position of the door by using the black and purple buttons Black moves the door UP open and purple moves the door DOWN close Setting the UP position 1 Press and hold the black button until the LED starts flashing slowly then release 2 Push and hold the black button until the door reaches the desired UP open position NOTE Make sure the door opens high enough for your vehicle 3 Push the door control or programmed remote control This sets the UP open limit
136. st compl tement a l oppose ferm e La porte tant ferm e raccorder la biellette droite au support de la porte l aide d un axe de chape de 5 16 po x 1 1 4 po Faire tenir l axe de chape avec un anneau d arr t Tirer sur la poign e de d clenchement manuel pour Support d connecter la partie ext rieure du chariot de sa de la porte Q d arr t partie int rieure en tirant vers le bas et en faisant glisser la partie ext rieure du chariot vers le moteur de l ouvre porte Biellette Connecter la biellette courb e au chariot l aide de l axe Axe de chape de droite de chape de 5 16 po x 1 1 4 po et de l anneau d arr t 5 16 de po x 1 1 4 de po em REMARQUE R glage de la fin de course de la page suivante Boulom de 9 5 16 de po 18 x 7 8 de po e Le chariot se raccordera automatiquement Sinon revoir la section portant sur la fonction de verrouillage du chariot la page 34 Lors du r glage de la course d ouverture la page suivante la porte ne devrait pas tre inclin e vers l arri re tel qu illustr ci dessous lorsqu elle est compl tement ouverte Une l g re inclinaison arri re entravera le mouvement ou provoquera un mouvement saccad de la porte lors de son ouverture ou de sa fermeture partir de la position compl tement ouverte Figure 6 BON MAUVAIS Biellette droite Biellette courb e A H Figure 6 Chariot int rieur Chariot ext rieur Poign e de
137. t l ext rieur du garage 1 Appuyer sur le bouton Prog LEARN de commande de la porte 2 Appuyer de nouveau sur le bouton Prog LEARN pour confirmer la s lection du mode LEARN A A ENTER 3 Rel cher le bouton lorsque 3 Introduire un num ro Y l clairage du moteur clignote Il Sl d d identification personnelle NIP a appris le code Si les ampoules quatre chiffres de son choix sur le ne sont pas pos es deux clics se LIA x pav num rique Enfoncer et tenir feront entendre N ensuite le bouton ENTER 4 L clairage du moteur clignote N d Pour modifier un NIP connu existant quand il a reconnu le code Si les EN Si le NIP existant est connu il peut tre modifi par une seule ampoules ne sont pas viss es o M personne sans devoir utiliser d chelle 1 Appuyer sur les quatre boutons correspondant au NIP actuel puis enfoncer et tenir le bouton L clairage de l ouvre porte clignotera deux fois Rel cher deux d clics se feront entendre le bouton 2 Introduire le NIP temporaire 4 chiffres choisi puis 2 Introduire le nouveau NIP 4 chiffres choisi puis appuyer appuyer sur ENTER sur ENTER L clairage de l ouvre porte clignotera quatre fois L clairage du moteur clignotera une fois lorsque le NIP aura 3 Pour d finir le nombre d heures de validit de ce NIP t appris temporaire appuyer sur le nombre d heures
138. t d allumer une lampe un t l viseur ou un autre appareil partir de la voiture avec l ouvre porte ou partir de n importe o dans la maison avec une autre t l commande Chamberlain Security4 42 CLDM1C 41A6345 1 T l commande 3 Bouton SECURITY Comprend agrafe de pare soleil Mini t l commande 3 Bouton SECURITY Avec porte cl et ruban d attache Entr e sans cl SECURITY Permet d ouvrir la porte de l ext rieur en entrant un mot de passe sur le clavier de conception sp ciale Peut galement ajouter un mot de passe temporaire pour les visiteurs ou les pr pos s au service Ce mot de passe programmable peut tre limit un nombre programmable d heures ou d entr es Syst me de d tection d ouverture de porte de garage Permet de surveiller la plus grande porte de votre domicile Commande de port sin fil Barre poussoir fonction d eclairage et bouton auxiliary Batterie incluse REMARQUE 43 SERVICE CHAMBERLAIN A VOTRE DISPOSITION NOTRE IMPORTANTE ORGANISATION DE SERVICE APRES VENTE COUVRE LES ETATS UNISET LE CANADA VOUS POUVEZ OBTENIR PAR T L PHONE DES INFORMATIONS SUR L INSTALLATION ET LE SERVICE APR S VENTE COMPOSEZ SIMPLEMENT NOTRE NUM RO DE SERVICE COMMENT COMMANDER DES PIECES DE RECHANGE Les prix de vente seront fournis sur demande ou bien les pi ces seront exp di es au prix en vigueur et vous seront factur e
139. t language ESPANOL Message Jao Meaning This message will appear when the Motion Sensing button is pressed MOTION SENSING ON The motion detector will toggle on or off with each press of the button MOTION SENSING OFF Message ES Meaning Opener is running on battery power BATTERY BACKUP ENABLED Message Jaume Meaning Opener is running on battery power with full charge BATTERY BACKUP ENABLED Message Rn Meaning Opener is running on battery power with low charge BATTERY LOW BATTERY BACKUP ENABLED Message Zane Meaning Battery is beyond a recoverable condition BATTERY BAD REPLACE BATTERY NOW SEE OWNER S MANUAL Message ES Meaning Battery charging from recent battery backup state POWER RESTORED BATTERY CHARGING PROGRAMMING NOTICE If this Security garage door opener is operated with a non rolling code remote control the technical measure in the receiver of the garage door opener which provides security against code theft devices will be circumvented The owner of the copyright in the garage door opener does not authorize the purchaser or supplier of the non rolling code remote control to circumvent that technical measure Your garage door opener has already been programmed at the factory to operate with your hand held remote control The door will open and close when you press the large push button Below are instructions for programming your opener to operate with additional Security 315 MHz remote
140. ted staples to secure wire in several places DO NOT pierce wire with a staple creating a short or open circuit 4 Strip 7 16 11 mm of insulation from end of bell wire Connect bell wire to the quick connect terminals as follows white to white and white red to red 5 Position the antenna wire as shown 6 Use tacks or staples to permanently attach entrapment warning label to wall near door control and manual release safety reverse test label in a prominent location on inside of garage door NOTE DO NOT connect power and operate opener at this time The trolley will travel to the full open position but will not return to the close position until the sensor beam is connected and properly aligned Top Mounting Hole Door Control Connections Strip wire 7 16 11 mm Ro Terminal 7 16 11 mj Screws Bottom Mounting Hole Bell Wire BACK VIEW AA WARNING To prevent possible SERIOUS INJURY or DEATH from electrocution Disconnect ALL electric and battery power BEFORE performing ANY service or maintenance Connect ONLY to 24 VOLT low voltage wires To prevent possible SERIOUS INJURY or DEATH from a closing garage door Install door control within sight of garage door out of reach of children at a minimum height of 5 feet 1 5 m and away from ALL moving parts of door NEVER permit children to operate or play with door control push buttons
141. the button number of hours or times to 0 in step 3 One Button Close Opener can be closed by pressing only the ENTER button if the one button close feature has been activated This feature has been activated at the factory To activate or deactivate this feature press and hold buttons 1 and 9 for 10 seconds The keypad will blink twice when the one button close is active The keypad will blink four times when one button close is deactivated 39 REPAIR PARTS Rail Assembly Parts KEY PART NO NO DESCRIPTION 4A1008 Master link kit 4105141 2 Complete trolley assembly 41A5665 2 Complete rail 41B4103 Spring trolley nut 144054 Idler pulley 41A5250 Full belt assembly 41D598 1 U bracket NOT SHOWN 183A163 Wear pads KEY PART NO NO DESCRIPTION 41A6318 Smart Control Panel 953CD 3 Button remote control 10A20 3V2032 Lithium battery 29B137 Remote control visor clip 41A2828 Emergency release rope and handle assembly 41B4494 1 2 Conductor bell wire white and white red 41A5047 1 Door bracket with clevis pin amp fastener 41A5047 3 Header bracket with clevis pin amp fastener 41A5034 Safety Reversing Sensors kit receiving and sending eyes with 3 9 m 2 conductor bell wire 178B34 Straight door arm section 12B776 Hanging brackets 178B35 Curved door arm section 41A5266 1 Safety Reversing Sensors brackets 2 41A6357 1 Battery NOT SHOWN 101D169 Push bar for door control 41A5257 20 Installation hardware bag inc
142. tion breaks the light beam while the door is closing the door will stop and reverse to full open position and the opener lights will flash 10 times The units must be installed inside the garage so that the sending and receiving eyes face each other across the door no more than 6 15 cm above the floor Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the track of sectional garage doors without additional hardware WARNING Be sure power is NOT connected to the garage door opener BEFORE installing the safety reversing sensor To prevent SERIOUS INJURY or DEATH from a closing garage door Correctly connect and align the safety reversing sensor This required safety device MUST NOT be disabled Install the safety reversing sensor so beam is NO HIGHER than 6 15 cm above garage floor If it is necessary to mount the units on the wall the brackets must be securely fastened to a solid surface such as the wall framing Extension brackets see Accessories are available if needed If installing in masonry construction add a piece of wood at each location to avoid drilling extra holes in masonry if repositioning is necessary The invisible light beam path must be unobstructed No part of the garage door or door tracks springs hinges rollers or other hardware may interrupt the beam whil
143. tional doors in Installation SERIOUSLY INJURED or KILLED by a closing garage Step 12 door Depending on your door s construction you may need The gap between the bottom of the garage door and additional mounting hardware for the door bracket the floor MUST NOT exceed 1 4 6 mm Otherwise Step 12 the safety reversal system may NOT work properly The floor or the garage door MUST be repaired to eliminate the gap ONE PIECE DOOR WITHOUT TRACK FINISHED CEILING Support bracket amp fastening hardware e is required Motor unit See page 16 Header Wall Wall mounted Door Control pe g Access Door CLOSED POSITION Trolley Bracket Door Bracket 5099992 Sy d Straight Door Arm Emergency Release Rope amp Handle Safety Reversing Sensor Gap between floor and bottom of door must not exceed 1 4 6 mm Curved Door m Safety Reversing Sensor ONE PIECE DOOR WITH TRACK Access CLOSED POSITION Door Trolley Stop Bolt Belt Tro Header Curved Bracket Door Arm 00000000000 i Emergency Bracket Straight Release Reversin Rope amp Gap between floor Sensor d 1 Garage rid Handle Safety and bottom of door Reversing must not exceed 1 4 6 mm Sensor Carton Inve
144. track e 8 20 cm above the high point for one piece door without track This height will provide travel clearance for the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 13 for ceiling installation 12 Unfinished Ceiling Header Wall OPTIONAL CEILING HEADER BRACKET Vertical Centerline of Garage Door Structural Supports optional DORE 3 zl Kod d Header Wall IT 2 5 cm Track Highest Point of Travel T Door Header Wall Highest Point of Travel Sectional door with curved track Header Wall FE 20 om j Highest Point of Travel Jamb Hardware One piece door with horizontal track Header Wall NT 8 20 cm Highest Point i of Travel Door One piece door without track jamb hardware One piece door without track pivot hardware INSTALLATION STEP 2 Install the Header Bracket You can attach the header bracket either to the wall above the garage door or to the ceiling Follow the instructions which will work best for your particular requirements Do not install the header bracket over drywall If installing into masonry use concrete anchors not provided WALL HEADER BRACKET INSTALLATION Center th
145. ts and or force if necessary See pages 28 and 29 Repeat the safety reverse test Make any necessary adjustments See Adjustment Step 3 Every Year Oil door rollers bearings and hinges The opener does not require additional lubrication Do not grease the door tracks 34 To prevent possible SERIOUS INJURY or DEATH NEVER allow small children near batteries f battery is swallowed immediately notify doctor To reduce risk of fire explosion or chemical burn Replace ONLY with 3V2032 coin batteries DO NOT recharge disassemble heat above 100 C 212 F or incinerate The lithium battery should produce power for up to 5 years To replace battery use the visor clip or screwdriver blade to pry open the case as shown Insert battery positive side up Dispose of old battery properly Replace the battery with ONLY 3V2032 coin cell batteries Battery positive NOTICE To comply with FCC and or Industry Canada rules IC adjustment or modifications of this receiver and or transmitter are prohibited except for changing the code setting or replacing the battery THERE ARE NO OTHER USER SERVICEABLE PARTS Tested to Comply with FCC Standards for Home or office use Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Ha
146. ue les d tecteurs se fassent face l un l autre de part et d autre de la porte du garage le faisceau n tant pas une hauteur de plus de 6 po 15 cm au dessus du sol Ils peuvent tre pos s de trois fa ons suivant vos exigences comme suit Pose aux guides de la porte de garage mode pr f rable Faire glisser les bras courb s par dessus le bord arrondi de chaque guide de porte les bras courb s tant dirig s vers la porte Enclencher en place contre le c t du guide II doit reposer plat avec le rebord embrassant le bord arri re du guide Figure 1 Si votre guide de porte ne supporte pas solidement le support une pose murale est recommand e Pose murale Figures 2 et 3 e Placer le support contre le mur les bras courb s tant dirig s vers la porte S assurer qu il y a un d gagement suffisant et qu aucun obstacle n est dans le parcours du faisceau du d tecteur Siune profondeur suppl mentaire est n cessaire on peut employer un support de rallonge se reporter la section Accessoires ou des blocs en bois e Utiliser les trous de montage de support comme gabarits pour positionner et percer deux avant trous de 3 16 de po de diam tre sur le mur de chaque c t de la porte une hauteur ne d passant pas 6 po 15 cm au dessus du sol e Fixer les supports au mur l aide de tire fond non fournis Sides supports de rallonge ou des blocs en bois sont employ s ajuster les ensembles droit
147. ur de c bles pr install s pour chacun des capteurs Figure 8 Connecter les c bles pr install s sur les c bles du capteur avec un capuchon de connexion en vous assurant que les couleurs correspondent sur chaque capteur Figure 9 Figure 5 e crou oreilles Boulon t te bomb e B et collet carr de 1 4 de po 20 x 1 2 de po Figure 6 Figure 7 Figure 8 C bles du capteur de l inverseur de securiti 7 16 de po 11 mm 1 C bles pr install s Figure 9 Non fournis C bles du capteur de l inverseur de securiti Blanc Blanc Noir C bles pr install s 22 Connexion l ouvre porte de garage Enlever 7 16 po 11 mm d isolation de chaque s rie de fils S parer les fils blanc et blanc noir suffisamment pour leur raccordement aux vis des bornes raccordement rapide de l ouvre porte Torsader les fils de m me couleur Ins rer les fils dans les trous raccordement rapide blanc blanc et noir blanc gris Figure 10 Figure 10 Raccorder les fils sur Plafond fini bornes raccordement rapide Li Fil de sonnerie cd H I 1 i ga Fil de sonnerie sd 1 D nuder le fil sur 7 16 po 11 mm H 7 16 po 11 mm IT 1 I 1 P Ke 2 Torsader les fils de i i m me couleur D I I H e 1 D tecteur ij inv
148. ux tests Le non respect de ces instructions invalide totalement la pr sente garantie Si au cours de la p riode de garantie limit e ce produit semble contenir un d faut couvert par la pr sente garantie limit e appeler le 1 800 528 9131 sans frais avant de d monter le produit Envoyer ensuite le produit en port pay et assur notre centre de service pour que la r paration soit couverte par la garantie On vous indiquera les directives d exp dition lorsque vous appellerez Une br ve description du probl me et un re u dat prouvant l achat devront tre joints tout produit retourn pour une r paration sous garantie Lorsque le Vendeur aura re u les produits qui lui sont retourn s pour r paration s il s av re que les produits taient effectivement d fectueux et couverts par la pr sente garantie limit e ils seront r par s ou remplac s la seule discr tion du Vendeur sans frais pour l acheteur puis retourn s en port pay Les pi ces d fectueuses seront r par es ou remplac es par de nouvelles pi ces ou des pi ces remises neuf en usine la seule discr tion du Vendeur TOUTES LES GARANTIES IMPLICITES POUR LE PRODUIT INCLUANT NOTAMMENT TOUTES LES GARANTIES IMPLICITES DE QUALIT MARCHANDE ET D ADAPTATION UNE UTILISATION PARTICULI RE SONT LIMIT ES EN DUR E UNE P RIODE DE GARANTIE LIMIT E DE CINQ ANS INDIQU E CI DESSUS L EXCEPTION DES GARANTIES IMPLICITES PORTANT SUR LA BATTERIE QUI SON
149. v e clair pour ouvrir ou fermer la porte Appuyer nouveau pour inverser la porte durant le cycle de fermeture ou pour arr ter la porte pendant son ouverture Cette commande de porte contient un d tecteur de mouvement e t moin duquel s allumera d s la d tection de l entr e d une personne dans la garage Barre Prog LEARN poussoir Heure Minute Langue Degr s F C Bouton CE d clairage C32 Bouton de verrouillage Fonction d clairage Appuyez sur le bouton d clairage pour allumer ou teindre l clairage de l ouvre porte Il ne contr le pas l clairage de l ouvre porte pendant que la porte est en mouvement Si vous allumez puis activez l ouvre porte clairage demeurera allum pendant 4 1 2 minutes Appuyez nouveau sur ce bouton pour l teindre plus t t L intervalle de 4 1 2 minutes peut tre chang 1 1 2 2 1 2 ou 3 1 2 minutes comme suit Enfoncer et tenir le bouton de blocage jusqu ce que l clairage clignote environ 10 secondes Un seul clignotement indique que la minuterie est r gl e 1 1 2 minute R p ter la proc dure et l clairage clignotera deux fois r glant ainsi la minuterie 2 1 2 minutes R p ter nouveau pour un intervalle de 3 1 2 minutes etc jusqu un maximum de quatre clignotements pour 4 1 2 minutes est recommand de d sactiver le d tecteur de mouvement en cas d usage de l clairage de l ouvre porte comme clai
150. ving a Problem Troubleshooting 1 My door will not close and the light bulbs blink on my motor unit The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction Verify the Safety Reversing Sensors are properly installed aligned and free of any obstructions Refer to Installation Step 11 Install The Protector System Check diagnostic LED for flashes on the motor unit then refer to the Diagnostic Chart on the following page My remotes will not activate the door Verify your Smart Control Panel is not blinking If it is blinking deactivate the Lock Mode following the instructions for Using the Wall Mounted Door Control Reprogram remotes following the programming instructions Refer to Programming If remote will still not activate your door check diagnostic LED for flashes on motor unit then refer to Diagnostic Chart on the following page My door reverses for no apparent reason Repeat safety reverse test after adjustments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Manually check door for balance or any binding problems Referto Adjustment Step 2 Set the Force My door reverses for no apparent reason after fully closing and touching the floor Repeat safety reverse test after adjustments to force or travel
151. votre ouvre porte en vue du fonctionnement avec d autres t l commandes Security 315 MHz Pour ajouter ou reprogrammer une t l commande main suppl mentaire UTILISATION DU BOUTON LEARN UTILISATION DE LA COMMANDE DE PORTE 1 Enfoncer et rel cher le bouton learn sur le moteur Le t moin lumineux learn s allumera en continu pendant 30 secondes 1 Appuyer sur le bouton Prog LEARN de commande de la porte 2 Appuyer de nouveau sur le bouton Prog LEARN pour confirmer la s lection du mode LEARN m Dans un d lai de 30 secondes enfoncer et tenir le bouton de la t l commande qui fera fonctionner votre porte de garage ER 3 Appuyer sur le bouton de la t l commande qui contr lera le fonctionnement de la porte de A 7 garage 3 Rel cher le bouton lorsque l clairage du moteur clignote Il N a appris le code Si les ampoules 4 L clairage du moteur clignote ne sont pas pos es deux clics S quand il a reconnu le code Si les x se feront entendre ampoules ne sont pas viss es deux d clics se feront entendre Pour effacer tous les codes de la m moire T l commandes a trois boutons 315 MHz du moteur Programm en usine le gros bouton dont pourrait tre Pour d sactiver tout
152. warrants to the first retail purchaser of this product for the residence in which this product is originally installed that it is free from defect in materials and or workmanship for a period of three years from the date of purchase and that the belt is free from defect in materials and or workmanship for a period of 10 years from the date of purchase and that the motor is free from defect in materials and or workmanship for the lifetime of the product The proper operation of this product is dependent on your compliance with the instructions regarding installation operation maintenance and testing Failure to comply strictly with those instructions will void this limited warranty in its entirety If during the limited warranty period this product appears to contain a defect covered by this limited warranty call 1 800 528 9131 toll free before dismantling this product Then send this product pre paid and insured to our service center for warranty repair You will be advised of shipping instructions when you call Please include a brief description of the problem and a dated proof of purchase receipt with any product returned for warranty repair Products returned to Seller for warranty repair which upon receipt by Seller are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or replaced with new or factory rebu
153. xer l aide d ancrages de b ton Non fournis F T moin lumineux Support de d tecteur MONTAGE ET C BLAGE DES D TECTEURS INVERSEURS DU SECURITIE Montage Faire glisser un boulon t te bomb e et collet carr de 1 4 po 20 x 1 2 po dans la fente de chaque d tecteur Utiliser des crous oreilles pour fixer les d tecteurs aux supports avec les diffuseurs dirig s l un vers l autre de part et d autre de la porte S assurer que le diffuseur n est pas obstru par une rallonge de support Figure 5 Serrer les crous oreilles la main Option A Installation sans les c bles pr install s Faites cheminer le c ble de la sonnerie depuis les deux capteurs vers l ouvre porte de garage Fixez le c ble au mur et au plafond avec des agrafes Figure 6 Option B Installation pr c bl e Si des c bles pour les capteurs de l inverseur de s curit sont d j install s dans votre garage appliquez les instructions ci dessous e Coupez l extr mit du c ble du capteur de l inverseur de s curit en vous assurant qu il reste suffisamment de longueur pour atteindre les c bles pr install s depuis le mur Figure 7 e S parez les c bles du capteur de l inverseur de s curit et d nudez sur chaque extr mit 7 16 po 11 mm de l isolant Choisissez deux des c bles pr install s et d nudez sur chaque extr mit 7 16 po 11 mm de l isolant Assurez vous de choisir la m me coule
154. y does not move away from the bolt repeat the steps above If battery status LED is not lit properly Check battery connections My garage door opener beeps Asolid LED with beep sounding approximately every 2 seconds indicates the motor unit is activating the door and is operating off of the battery Aflashing LED with beep sounding every 30 seconds indicates battery is low e fared LED remains on when the power is restored and is accompanied by a beep sounding every 30 seconds replace the battery Diagnostics Located On A Motor Unit _ 2 777 6002090 LI LI L O Learn EE Button LED or O Diagnostic jr Your garage door opener is programmed with self diagnostic Safety Reversing Sensor Learn capabilities The Learn button diagnostic LED will flash a Button number of times then pause signifying it has found a potential issue Consult Diagnostic Chart below Diagnostic Chart 1 FLASH occ Q Symptom One or both of the Indicator lights on the safety reversing sensors Safety reversing sensors do not glow steady M wire open broken or Inspect sensor wires for a short staple in wire correct wiring polarity black disconnected white wires reversed broken or disconnected wires replace attach as needed OR Disconnect all wires from back of motor unit Remove sensors from brackets and shorten
Download Pdf Manuals
Related Search
Related Contents
Manual de utilização SL-23185QS10 - Emerson Network Power 取扱説明書 MANUAL DEL USUARIO Mode d`emploi WCT850 Heavy-Duty Commercial Toaster Instruction Manual T-PDS Windows - inverter & Plc Planet Technology VIP-254PT Telephone User Manual LICITACION ABREVIADA N° 9/2013 Copyright © All rights reserved.
Failed to retrieve file