1. HP 16505A Prototype Analyzer Interface 2 8 Installing the Interface Module WARNING CAUTION Installing the Interface Module To Install the HP 16500H Hardware To Install the HP 16500H Hardware If you need instructions for removing and replacing parts of the HP 16500B refer to the HP 16500B Logic Analysis System Service Guide SHOCK HAZARD Disconnect the power from the mainframe before performing the following procedures After disconnecting the power wait at least six minutes for the capacitors on the power supply board and the CRT driver board to discharge before servicing the instrument Failure to do so could result in electrical shock Hazardous voltages exist on the power supply the CRT and the CRT driver board of the HP 16500B mainframe As long as the AC LED on the power supply has any illumination a significant charge remains on the capacitors Use grounded wriststraps and mats when performing any service to this module or to the HP 16500B Logic Analysis System Electrostatic discharge can damage electronic components For correct orientation of the cables match the slots on the cable connectors and on the board connectors Remove power from the HP 16500B mainframe then remove the measurement modules the four rear feet and the top and bottom covers of the mainframe Remove the sheetmetal plate on the rear of the mainframe covering the slot where the interface module will be installed With the interface module i
2. all work and close all windows b Open the Session Manager window then select Power Down c Remove power from the HP 16505A Prototype Analyzer then remove power from the HP 16500B mainframe d Disconnect the HP 16505A interface cable HP 16501A interface cable and LAN cable from the interface board Turn off the power switch located on the front panel of the HP 16500B mainframe and the standby switch located on the rear panel Then unplug the power cord from the mainframe Refer to the HP 16500B Service Guide if you need instructions for removing and replacing parts of the HP 16500B Remove the two rear feet on the top and the top cover of the HP 16500B mainframe On the interface module disconnect the cable from the CPU board 3 10 Servicing the Interface Module Removing and Replacing the HP 16500H Interface Module 5 Remove the screws connecting the interface module to the mainframe Two screws through the top of the interface module connect it to the sheetmetal plate and four screws connect the rear plate of the interface module to the rear panel of the mainframe see the figure below Two board to mainframe screws Interface Module to CPU cable Four faceplate to mainframe screws 16505p05 Removing the Interface Module 3 11 Servicing the Interface Module Removing and Replacing the HP 16500H Interface Module Install the new interface module by reversing this procedure Test the performa
3. can be accessed in the Communications menu The interface module automatically obtains the subnet mask by sending a broadcast ICMP query over the network The broadcast ICMP query is transmitted approximately 10 seconds after power is applied to the interface module and approximately 2 seconds after the IP address is changed When the query is answered by another network device the interface module stores the information in internal memory 2 5 Installing the Interface Module Ethernet LAN Interface Verify connectivity with an echo request In most network environments an echo request is accomplished using the ping utility For the exact syntax for the ping or other echo request utility refer to your network documentation A normal response to multiple echo requests is 9 10 or possibly 11 packets transmitted for every 10 echo requests If there is no response to the echo request first check the command line If an IP address is used in the echo request command line then the IP address typed in the command line should match the IP address stored in the HP 16500B Ethernet Configuration menu If a hostname was used in the command line then check the node names database to see that the IP address and the hostname for the HP 16500B were correctly entered After verifying the command line check to make sure the hardware is connected and operating properly To verify operation of the interface module refer to To verify the interface
4. module performance in Chapter 3 An intermittent response to the echo request indicates a problem with the LAN itself Use a LAN analyzer or LAN management software to monitor activity and determine where bottlenecks or other problems are occurring Mount the HP 16500B system with an NFS mount An NFS mount of the 16500B system depends on the network environment the system is being mounted to For UNIX the mount command with the computer name and mount point are required In MS DOS a virtual drive specifier and 16500B IP address are required File Manager in MS Windows is used to mount in an MS Windows environment In all cases either the 16500B file server control or data directory must be specified depending on whether the 16500B system is being mounted for control or data The normal response to an NFS mount in most cases is the command line prompt reappears If the system includes a utility to view the mount table for example in UNIX the mount command alone displays etc mnttab then the 16500B remote file server should appear in the table of mounted devices If error messages appear then check the command line syntax If the syntax is correct then resolve the error message directly using your network documentation Note that an error message appears if you try to mount too soon after power up You need to wait at least 15 seconds after the System Configuration menu is displayed on the HP 16500B display before attempting to mou
5. screen Configuration Master Frame as a Keyboard A 1 0M SAMPLE E 7 1107500MHz LA Communications ions Ethernet Ethernet should be HP IB 7 RS 232C listed here High speed Printer Setup RS 232C 3 3 Servicing the Interface Module Verify the Interface Module Performance If the Ethernet selection appears in the Communications menu then go to step 5 If Ethernet does not appear in the Communications menu perform the following steps a b Remove power from the HP 16500B disconnect the power cable then remove the top cover Remove and inspect the interface module cable for signs of damage If the cable appears defective replace it Ensure that the cable is connected according to the installation procedures and that all cables are properly seated For installation procedures refer to chapter 2 Installing the Interface Module Install the top cover of the HP 16500B mainframe connect the power cable and reapply power If Ethernet still does not appear then suspect a defective CPU board Refer to the HP 16500B 16501A Service Guide for infomation on testing and replacing the CPU baord Touch Configuration then touch Test When the test menu appears touch the blue field to load the performance verification test system 6 Touch Test System then s Servicing the Interface Module Verify the Interface Module Performance elect Mainframe Test in the pop up menu The scree
6. About this Manual We ve added this manual to the Agilent website in an effort to help you support your product This manual is the best copy we could find it may be incomplete or contain dated information If we find a more recent copy in the future we will add it to the Agilent website Support for Your Product Agilent no longer sells or supports this product Our service centers may be able to perform calibration if no repair parts are needed but no other support from Agilent is available You will find any other available product information on the Agilent Test amp Measurement website www tm agilent com HP References in this Manual This manual may contain references to HP or Hewlett Packard Please note that Hewlett Packard s former test and measurement semiconductor products and chemical analysis businesses are now part of Agilent Technologies We have made no changes to this manual copy In other documentation to reduce potential confusion the only change to product numbers and names has been in the company name prefix where a product number name was HP XXXX the current name number is now Agilent XXXX For example model number HP8648A is now model number Agilent 8648A Installation and Service Guide Publication number 16500 97012 First edition April 1995 For Safety information Warranties and Regulatory information see the pages behind the index Copyright Hewlett Packard Company 1993 1994 1995 All Rights Rese
7. Parts 3 13 Ordering Replacable Parts 3 14 Replacable Parts 3 15 Servicing the Interface Module Servicing the Interface Module Verify the Interface Module Performance Verify the Interface Module Performance Before starting the interface module performance verification check all cables and connectors to ensure that all cables are properly connected The interface module performance verification self test is divided into two sections The first section tests the physical connection for example the cable and termination The second section tests the internal functions of the LAN IC on the LAN interface module When both sections of the self test have been completed a status reporting message appears in the Option Board Test menu The status reporting message indicates whether the tests pass if a failure occurs and which section failed The first section the physical connection is tested depending on the LAN topology used Because EtherTwist 10Base T is used the interface module will listen for the heartbeat signal from the LAN If a heartbeat is received then the physical connection is considered good The second section is tested using internal loopback features of the LAN IC Transmitted packets are looped back to the receive circuit of the LAN IC When the looped back packets are received they are processed like a packet received from a remote client or server If the looped back packet is recognized and processed then t
8. cations for the product or improper site preparation or maintenance No other warranty is expressed or implied Hewlett Packard specifically disclaims the implied warranties of merchantability or fitness for a particular purpose Exclusive Remedies The remedies provided herein are the buyer s sole and exclusive remedies Hewlett Packard shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any other legal theory Assistance Product maintenance agreements and other customer assistance agreements are available for Hewlett Packard products For any assistance contact your nearest Hewlett Packard Sales Office Certification Hewlett Packard Company certifies that this product met its published specifications at the time of shipment from the factory Hewlett Packard further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology to the extent allowed by the Institute s calibration facility and to the calibration facilities of other International Standards Organization members About this edition This is the first edition of the HP 16500H Interface Module Installation and Service Guide Publication number 16500 97012 Printed in USA Edition dates are as follows First edition May 1995 New editions are complete revisions of the manual Update packag
9. cific ordering information are available through your local Hewlett Packard Sales Office Addresses and telephone numbers are located in a separate document at the back of the HP 16500B Service Guide 3 14 Servicing the Interface Module Replaceable Parts List Replaceable Parts List HP 16500H Interface Module Replacment Parts Designator HP Part Number QTY Description A3 16500 66514 1 Interface Board H2 0515 0372 6 Machine Screw w1 16500 61613 1 10 40 Cable W2 16500 61614 1 ee CPU Interface Board able This cable is only used if the HP 16500H is installed in place of an HP 16500L interface module HP 16500H Replaceable parts 3 16 Index A accessories 1 3 Cc cables connecting 3 11 orientation 2 2 connections 1 3 D direct mail order system 3 14 E echo request 2 5 Ethernet installation 2 5 expansion frame 2 7 F faulty cable or HP 16500H performance verification 3 3 H HP 16501A Expansion Frame 2 7 HP 16505A Prototype Analyzer 2 8 I installation expansion frame 2 7 LAN 2 5 Prototype Analyzer 2 8 verifying 2 4 installing the hardware 2 2 2 3 L LAN installation 2 5 LAN support 1 4 M mail orders 3 14 Mainframe Test menu 3 5 o operating requirements 1 3 Option Board Test accessing 3 5 running 3 5 ordering parts 3 14 overview 1 2 P parts ordering 3 14 parts not listed 3 14 returning 3 13 performance verification failures 3 6 procedure 3 3 self test descript
10. es which are issued between editions contain additional and replacement pages to be merged into the manual by you The dates on the title page change only when a new edition is published A software or firmware code may be printed before the date This code indicates the version level of the software or firmware of this product at the time the manual or update was issued Many product updates do not require manual changes and conversely manual corrections may be done without accompanying product changes Therefore do not expect a one to one correspondence between product updates and manual updates The following list of pages gives the date of the current edition and of any changed pages to that edition All pages original edition DECLARATION OF CONFORMITY according to ISO IEC Guide 22 and EN 45014 Manufacturer s Name Hewlett Packard Company Manufacturer s Address Colorado Springs Division 1900 Garden of the Gods Road Colorado Springs CO 80907 U S A declares that the product Product Name Prototype Analyzer Model Number s HP 16505A 16500H Product Option s All conforms to the following Product Specifications Safety IEC 348 1978 HD 401 S1 1981 UL 1244 CSA C22 2 No 231 Series M 89 CISPR 11 1990 EN 55011 1991 Group 1 ClassA IEC 801 2 1991 EN 50082 1 1992 4kVCD 8kV AD IEC 801 3 1984 EN 50082 1 1992 3 V m 1kHz 80 AM 27 1000 MHz IEC 801 4 1988 EN 50082 1 1992 0 5 kV Sig Lines 1 kV Power L
11. he LAN IC and the LAN function are considered good The Option Board Test also tests the system integrity of the High Speed Port on the interface module If an HP 16501A Expandsion Frame is connected the Option Board Tests can also be used to test the expansion frame interface Procedure Servicing the Interface Module Verify the Interface Module Performance This procedure verifies the performance of the interface module To verify performance of the HP 16500B Logic Analysis System or the optional measurement modules refer to the Service Guides for those products If the screen appears blank the interface module or cable may be defective a Remove power from the HP 16500B disconnect the power cable then remove the top cover b Remove and inspect the interface module cable for signs of damage If the cable appears defective replace it c Ensure that the cable is connected according to the installation procedures and that all cables are properly seated For installation procedures refer to chapter 2 Installing the Interface Module d Install the top cover of the HP 16500B mainframe connect the power cable and reapply power Touch the blue field in the upper left corner of the HP 16500B screen Select System from the pop up menu Touch the blue field immediately to the right In the pop up menu select Configuration Verify that Ethernet is available in the Communications menu on the HP 16500B System Configuration
12. ines Supplementary Information The product herewith complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC Colorado Springs 9 15 94 John Strathman Quality Manager European Contact Your local Hewlett Packard Sales and Service Office or Hewlett Packard GmbH Department ZQ Standards Europe Herrenberger Strasse 130 D 71034 B blingen Germany FAX 49 7031 14 3143
13. ing checks Check that the LAN cable is properly seated at both the interface module and at the client server router ends Check that the LAN cable is good and that all signal lines in the cable have electrical integrity e To replace a defective interface module refer to Removing and replacing the interface module later in this chapter Exit the Test System a Touch the Module field then touch Test System b Touch the Menu field then touch Exit Test c Touch the field near the center of the screen to exit the test system and to load the operating system Servicing the Interface Module Troubleshooting an HP 16501A Expansion Frame Troubleshooting an HP 16501A Expansion Frame For details on troubleshooting a system that is connected to an HP 16501A Expansion Frame refer to the HP16500B 16501A Logic Analysis System Service Manual If you suspect that the HP 16500H Interface Module is defective use the procedures in this chapter to verify the interface module performance and if necessary replace the hardware The expnasion frame is recognized by the mainframe if the Master Frame text on the left side of the mainframe power up screen appears as a blue user select field If the text does not appear as a blue field the most likely cause is a defective interface module 3 7 Servicing the Interface Module Troubleshooting in an Ethernet LAN Environment Troubleshooting in an Ethernet LAN Environment For details on troubleshoo
14. inoperative and secure it against any unintended operation e Do not operate the instrument in the presence of flammable gasses or fumes Operation of any electrical instrument in such an environment constitutes a definite safety hazard e Do not install substitute parts or perform any unauthorized modification to the instrument e Capacitors inside the instrument may retain a charge even if the instrument is disconnected from its source of supply Use caution when exposing or handling the CRT Handling or replacing the CRT shall be done only by qualified maintenance personnel Safety Symbols A Instruction manual symbol the product is marked with this symbol when it is necessary for you to refer to the instruction manual in order to protect against damage to the product Hazardous voltage symbol Earth terminal symbol Used to indicate a circuit common connected to grounded chassis WARNING The Warning sign denotes a hazard It calls attention to a procedure practice or the like which if not correctly performed or adhered to could result in personal injury Do not proceed beyond a Warning sign until the indicated conditions are fully understood and met CAUTION The Caution sign denotes a hazard It calls attention to an operating procedure practice or the like which if not correctly performed or adhered to could result in damage to or destruction of part or all of the produc
15. ion 3 2 ping 2 5 Prototype Analyzer 2 8 R removing the interface module 3 10 3 12 replacing the interface module 3 10 3 12 requirements 1 3 returning parts 3 13 S self tests power up 2 4 T troubleshooting HP 16501A Expansion Frame 3 7 in an Ethernet LAN environment 3 8 in the HP 16505A Prototype Analyzer environment 3 9 U unmounting from a LAN 3 10 vV verifying the installation 2 4 Index 1 Index 2 Copyright Hewlett Packard Company 1995 All Rights Reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws Document Warranty The information contained in this document is subject to change without notice Hewlett Packard makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability or fitness for a particular purpose Hewlett Packard shall not be liable for errors contained herein or for damages in connection with the furnishing performance or use of this material Hewlett Packard P O Box 2197 Safety This apparatus has been designed and tested in accordance with IEC Publication 348 Safety Requirements for Measuring Apparatus and has been supplied in a safe condition This is a Safety Class I instrument provided with terminal for protective earthing Before applying power verify that the correct safety precautions a
16. n will display the Mainframe Test menu Mainframe Test ROM Test UNTESTED status Disk Test status UNTESTED RAM Test status UNTESTED Intermodule Test status UNTESTED HP IB Test status UNTESTED RS 232C Test status UNTESTED Color Display Test status UNTESTED on Board Test HIL Test status UNTESTED All System Tests status UNTESTED 7 Select Option Board Test then select Run Mainframe Test status Expander Test Lan Test Memory Interface z MAC s ENDEC TRANS High Speed Port Test NOTE The Expander Test ro expansion board These logic analyzer See th The Lan Test verifie lan interface Referen for more details about failures ie utes known signals to the can be captured by another e service manual for details s the functionality of the ce the Lan Manual eee status If an HP 16501A expansion frame is not connected then expect a No Expansion Card Present message to appear when you run the Option Board Test Refer to the HP 16500B 16501A Service Guide for more information about the expansion frame 3 5 Servicing the Interface Module Verify the Interface Module Performance Verify that the tests pass If all of the tests pass then go to the step 9 If any of the tests fail then LAN hardware or the interface module is suspect e To verify the LAN hardware perform the follow
17. nce of the interface board Refer to Verifying the interface module performance in this chapter for the performance verification test procedure Reconnect the HP 16505A or HP 16501A to the interface board or reconnect the interface board to your network If you are reconnecting to a network refer to the LAN Administartor s and Service Guide or check with your system administrator for reconnecting instructions The Ether Address of the replacement interface module will be different than the other module At powerup the HP 16500B operating system reads the address of the interface module then records the address in memory If your network configuration did not change the addresses and information in the configuration menus will remain the same 3 12 CAUTION Servicing the Interface Module Returning Parts Returning Parts Before shipping the module to Hewlett Packard contact your nearest Hewlett Packard sales office for additional details Write the following information on a tag and attach it to the part to be returned e Name and address of owner e Model number e Description of service required or failure indications Remove accessories from the module Only return accessories to Hewlett Packard if they are associated with the failure symptoms Package the module or assemblies You can use either the original shipping containers or order materials from an HP sales office Package the interface module in elec
18. nstalled you will not use the plate Save the plate to use in case the interface module is removed Installing the Interface Module To Install the HP 16500H Hardware 3 Slide the interface module into the mainframe through the slot in the rear panel 4 Install the screws connecting the interface module to the mainframe Two screws through the top of the interface module connect it to the sheetmetal plate and four screws through the rear plate of the interface module connect it to the rear panel of the mainframe 5 Connect the 80 pin cable to the CPU board and to the interface module Before installing the cable inspect the cable and the connectors for any signs of damage a Slide the 80 pin cable halfway through the rear slot of the card cage between the interface module and the CPU board b Connect the cable to the CPU board c Connect the cable to the interface module 6 Replace the top and bottom covers the optional modules and the rear feet of the mainframe ta mainframe screws Interface Module to CPU cable Four faceplate to mainframe ee screws Ss Installing the Interface Module 2 3 Installing the Interface Module To Verify the Installation To Verify the Installation Check that Ethernet is available in the Communications menu of the mainframe System Configuration menu When you power up the mainframe the Logic Analysis System performs the power up self tests After the self tests are fini
19. nt 2 6 Installing the Interface Module HP 16501A Expansion Frame Interface HP 16501A Expansion Frame Interface The interface port for the HP 16501A Expansion Frame permits you to quickly and easily connect an expansion frame to the HP 16500B mainframe With an expansion frame connected to the mainframe a total of ten 16500 series measurement modules can be configured and utilized Detailed service information for the HP 16500B mainframe and 16501A Expansion frame is covered in the HP 16500B 16501A Service Manual The expansion frame is recognized by the mainframe if the Master Frame text on the left side of the mainframe power up screen appears as a blue user select field If the text does not appear as a blue field the most likely cause is a defective interface module 2 7 Installing the Interface Module HP 16505A Protoytype Analyzer HP 16505A Protoytype Analyzer The high speed interface port for an HP 16505A Protoytype Analyzer permits you to connect a Prototype Analyzer to the HP 16500B mainframe Detailed installation information is covered in the HP 16505A Prototype Analyzer Installation Guide Verifying the Interface Module Performance 3 2 Performance verification procedure 3 3 Troubleshooting an HP 16501A Expansion Frame 3 7 Troubleshooting in an Ethernet LAN Environment 3 8 Troubleshooting in the HP 16505A Prototype Analyzer Environment 3 9 Removing and Replacing the HP 16500H Interface Module 3 10 Returning
20. on 2 4 Ethernet LAN Interface 2 5 HP 16501A Expansion Frame Interface 2 7 HP 16505A Protoytype Analyzer 2 8 Servicing the Interface Module Verify the Interface Module Performance 3 2 Troubleshooting an HP 16501A Expansion Frame 3 7 Troubleshooting in an Ethernet LAN Environment 3 8 Troubleshooting in the HP 16505A Prototype Analyzer Environment 3 9 Removing and Replacing the HP 16500H Interface Module 3 10 Returning Parts 3 13 Ordering Replaceable Parts 3 14 Replaceable Parts List 3 15 Contents 1 Contents 2 Introducing the HP 16500H 1 2 Accessories Supplied 1 3 Requirements 1 3 Physical Connections 1 3 LAN Support 1 4 Introducing the HP 16500H Interface Module Expander Frame connector Ethertwist Introducing the HP 16500L LAN Interface Module The HP 16500H LAN interface module provides three capabilities for your HP 16500 Logic Analysis System e connection to an Ethernet 10Base T Local Area Network LAN e connection to an HP 16501A Expansion Frame for the HP 16500B Logci Analysis System a high speed port for connecting the HP 16500B to an HP 16505A Prototype Analyzer LAN connector High speed port The HP 16500H interface module 1 2 Introducing the HP 16500H Interface Module Accessories Supplied Accessories Supplied The HP 16500H is shipped with the following accessories e this Installation and Service Guide e a LAN Administrator s and Service Guide e a LAN User
21. re taken see the following warnings In addition note the external markings on the instrument that are described under Safety Symbols Warning e Before turning on the instrument you must connect the protective earth terminal of the instrument to the protective conductor of the mains power cord The mains plug shall only be inserted in a socket outlet provided with a protective earth contact You must not negate the protective action by using an extension cord power cable without a protective conductor grounding Grounding one conductor of a two conductor outlet is not sufficient protection e Only fuses with the required rated current voltage and specified type normal blow time delay etc should be used Do not use repaired fuses or short circuited fuseholders To do so could cause a shock of fire hazard 1900 Garden of the Gods Road Colorado Springs CO 80901 e Service instructions are for trained service personnel To avoid dangerous electric shock do not perform any service unless qualified to do so Do not attempt internal service or adjustment unless another person capable of rendering first aid and resuscitation is present e If you energize this instrument by an auto transformer for voltage reduction make sure the common terminal is connected to the earth terminal of the power source e Whenever it is likely that the ground protection is impaired you must make the instrument
22. rved HP 16500H Interface Module See Also In This Book This book shows you how to install and service the HP 16500H Interface Module This book contains the following chapters e Chapter 1 provides and overview of the HP 16500H e Chapter 2 shows you how to install the HP 16500H in the HP 16500B mainframe This chapter also provides information on where to go next depending on which environment you are using the HP 16500 system in e Chapter 3 contains the procedures for performance verification and replacing assemblies This chapter tells you where to find information on troubleshooting the system depending on which environment you are using the HP 16500B system in The HP 16500H LAN Interface Module Administrator s and Service Guide for information on installing and setting up the HP 16500H in the LAN environment The HP 16500B Logic Analysis System Setting UP the System Guide for information on installing and setting up an HP 16501A Expansion Frame The HP 16505A Prototype Analyzer Installation Guide for information on installing and setting up an HP 16505A Prototype Analyzer The Logic Analyzer Training Kit if you are unfamiliar with the basic operation of the HP 16500B system il Contents Introducing the HP 16500H Interface Module Accessories Supplied 1 3 Requirements 1 3 Physical Connections 1 3 LAN Support 1 4 Installing the Interface Module To Install the HP 16500H Hardware 2 2 To Verify the Installati
23. s Guide e screws and one cable to install the HP 16500H into the HP 16500B mainframe e TORX 10 and TORX 15 wrenches If your HP 16500H was installed into the HP 16500B by HP you will not receive these tools If your HP 16500H was not installed by HP you will receive these tools Requirements HP 16500B Logic Analysis System mainframe and one of the following e NFS or FTP capabilities on your TCP IP Ethernet LAN or e HP 16501A Expansion Frame or e HP 16505A Prototype Analyzer Physical Connections e RJ 45 connector for direct connection to 10Base T networks e 68 pin D connector for connection to an HP 16501A Expansion Frame e High speed port for connection to an HP 16505A Prototype Analyzer 1 3 Introducing the HP 16500H Interface Module LAN Support LAN Support For information about the LAN protocols and file types supported by the HP 16500H refer to the LAN Administrator s and Service Guide This chapter includes procedures to install the interface module into the HP 16500B Logic Analysis System mainframe and to verify the installation For detailed information on how to install the HP 16500B in one of the three applications supported by the interface module refer to the documentation for the specific application This chapter provides references to those other documents To Install the HP 16500H Hardware 2 2 To Verify the Installation 2 4 Ethernet LAN Interface 2 5 HP 16501A Expansion Frame Interface 2 7
24. shed the screen displays the System Configuration menu Ifthe operating system finds an interface module installed then Ethernet is available in the Communications menu If Ethernet is not available in the Communications menu go to Verifying the Interface Module Performance in Chapter 3 of this manual Configuration Master Frame B a Keyboard A 1 0M SAMPLE 7 i 1107 500MHz LA Communications ions Fineret Ethernet should be RS 232C listed here High speed Printer Setup RS 232C Verifying the Installation 2 4 Installing the Interface Module Ethernet LAN Interface Ethernet LAN Interface The LAN interface provides a network based interface between the HP 16500B Logic Analysis System and personal computers and workstations over a 10Base T Ethernet LAN Detailed information on installing and troubleshooting in the LAN environment is covered in the HP 16500H LAN Administrator s and Service Guide The following steps are an overview of the process with some troubleshooting hints Connect an EtherTwist 10Base T LAN cable into the RJ 45 LAN port on the interface module If your LAN uses ThinLAN connections a Media Access Unit MAU is required Set up the configuration menus on the HP 16500B mainframe You can configure the interface module to work with your network from the HP 16500B front panel touchscreen After the HP 16500B power up tests are complete the Ethernet configuration
25. t Do not proceed beyond a Caution symbol until the indicated conditions are fully understood or met Product Warranty This Hewlett Packard product has a warranty against defects in material and workmanship for a period of one year from date of shipment During the warranty period Hewlett Packard Company will at its option either repair or replace products that prove to be defective For warranty service or repair this product must be returned to a service facility designated by Hewlett Packard For products returned to Hewlett Packard for warranty service the Buyer shall prepay shipping charges to Hewlett Packard and Hewlett Packard shall pay shipping charges to return the product to the Buyer However the Buyer shall pay all shipping charges duties and taxes for products returned to Hewlett Packard from another country Hewlett Packard warrants that its software and firmware designated by Hewlett Packard for use with an instrument will execute its programming instructions when properly installed on that instrument Hewlett Packard does not warrant that the operation of the instrument software or firmware will be uninterrupted or error free Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the Buyer Buyer supplied software or interfacing unauthorized modification or misuse operation outside of the environmental specifi
26. ting a system that is connected to an Ethernet LAN refer to the HP16500H LAN Administrator s and Service Guide If you suspect that the HP 16500H Interface Module is defective use the procedures in this chapter to verify the interface module performance and if necessary replace the hardware Servicing the Interface Module Troubleshooting in the HP 16505A Prototype Analyzer Environment Troubleshooting in the HP 16505A Prototype Analyzer Environment For details on troubleshooting a system that is connected to an HP 16505A Protoype Analyzer refer to the HP16505A Prototype Analyzer Service Guide If you suspect that the HP 16500H Interface Module is defective use the procedures in this chapter to verify the interface module performance and if necessary replace the hardware 3 9 Servicing the Interface Module Removing and Replacing the HP 16500H Interface Module Removing and Replacing the HP 16500H Interface Module If the HP 16500B Logic Analysis System is connected and mounted to a LAN then unmount the HP 16500B file system Unmounting from a LAN You must unmount the HP 16500B before power is removed from it Then you can mount the HP 16500B 15 seconds after the System Configuration menu is displayed when powering up the instrument You can write a network script that executes an unmount and mount procedure If the HP 16500B Logic Analysis System is being used in the HP 16505A prototype analyzer environment a Save
27. trostatic material Failure to do so could cause electrostatic discharge damaging the module Seal the shipping container securely and mark it FRAGILE Servicing the Interface Module Ordering Replaceable Parts Ordering Replaceable Parts Parts listed To order a part on the list of replaceable parts quote the Hewlett Packard part number indicate the quantity desired and address the order to the nearest Hewlett Packard Sales Office Parts not listed To order a part not on the list of replaceable parts include the model number of the module a description of the part including its function and the number of parts required Address the order to your nearest Hewlett Packard Sales Office Direct mail order system To order using the direct mail order system contact your nearest Hewlett Packard Sales Office Within the USA Hewlett Packard can supply parts through a direct mail order system The advantages to the system are direct ordering and shipment from the HP Part Center in Mountain View California There is no maximum or minimum on any mail order There is a minimum amount for parts ordered through a local Hewlett Packard Sales Office when the orders require billing and invoicing Transportation costs are prepaid there is a small handling charge for each order and there are no invoices In order for Hewlett Packard to provide these advantages a check or money order must accompany each order Mail order forms and spe

Download Pdf Manuals

image

Related Search

Related Contents

ADSP-2100 Family Assembler Tools & Simulator Manual  CRONO TWIN - Pompe infusionali  Beko TL577AP  Ewent EW1251  Samsung E2550D Lietotāja rokasgrāmata  CHLEF MEDICAL N° 9  Psc - Fondazione Arena di Verona  VR3 Multigas - Multimodus - bei Swiss-Cave  Turbofan G32D Service Manual.pub  Supermicro 4021GA-62R+F  