Home
        PPC-HDD(MS) User`s Guide
         Contents
1.    Mitsubishi General purpose Sequencer QCPU  Q Mode  User   s  Manual  Hardware Design  Maintenance and Inspection        Device is to be powered by limited Voltage Current circuit of Listed Power Supplies    Models   Q61P A1  Q61P A2  Q61P  Q63P  Q64P  manufactured by Mitsubishi Electric Corp     Fastening the Hard Disk Unit      Fit the unit fixing hook in the unit fixing slot in the base unit  then push the hard disk unit in the  direction of the arrow to set the hard disk unit on the base unit             Unit fixing hook    After setting the hard disk unit on the base unit  be sure to use the attached unit fixing screw to fasten  the hard disk unit to the base unit     Tighten the screw within the following torque range     Tightening torque range  36 to 48N cm       If the hard disk unit may be subject to vibration between 4 9 and 9 8 m s     use a set of hard disk unit  shock proof brackets  PPC HBR 01  available as an option  For installing the base unit with the hard  disk unit on the control panel  refer to the manual for the shock proof brackets        CONTEC  PPC HDD MS        PPC HDD MS  User s Guide    Functions of Components    Component Locations    Front panel                                                                                                             1  PPC   HOD  o  access O lt            Access LED   lt            Enhanced slave  IDE interface connector  Buve  Internal disk master slave selector switch    Set the first and second disk units
2.   compatible  with the Mitsubishi Programmable Logic Controller MELSEC Q series     The drive in the hard disk unit is a 2 5 inch IDE hard disk with a storage capacity of 40 GB     For configuration of the system using the hard disk unit and its connection  refer to the  PPC CPU686 MS  user s manual     Product Configuration       CONTEC  PPC HDD MS     Unit   1  User   s Guide  this booklet     1  IDE connection cable   1    Unit fixing screw   1  M3 x 12mm        PPC HDD MS  User s Guide    Specifications    Function Specifications  Internal drive    Transfer rate  Max   66 6MB sec  Ultra DMA Mode 4   16 6MB sec  PIO Mode 4   Reliability 1 10 8bits read    lunowbitsread oo  Connection to PC CPU Module  Extension 40 pin half pitch connector for connecting slave IDE device  Capable of connecting one IDE device with master slave selector switch  Access indicator  2    High temperature detection Ambient temperature detected 47     3  C or higher  Warning method  High temperature detection function of bus interface driver software    External dimensions  mm   Power consumption  Weight  Average life  3     1 1GB   1 000 000 000bytes        2 When two disk units  hard disk and or silicon disk units  are connected in a master slave arrangement  they have  common access indication  When either of the master and slave devices is accessed  therefore  both of their access  lamps come on at the same time     3 Under the assumptions   Less than 333 power on hours per month  And Seeking W
3.  as the master and slave devices  respectively   s M lt      When only one disk unit is used  set it as the master device    ye Factory default  M Master device   Bottom   Front  co     Ce  Ce  Es al  Ce           pana          D   D   D  E IDE interface connector  D  For connection to the PC CPU Module    D  mmp  D   Rear   Ge     For the pin assignments in the IDE interface and Enhanced IDE interface connectors  refer to the user    s  manual for the PC CPU Module        CONTEC  PPC HDD MS  6       PPC HDD MS  User s Guide    Master Slave Arrangement    PPC HDD MS  or PPC SDD MS  xx   Disk unit   Master Slave    PPC CPU686 MS    PC CPU Module           ee  ele   oO  rele   0   0                                            Connect the master and slave disk units  with an IDE connection cable                                         t    Set this to Slave  S                        Set this to Master  M         Connect the PC CPU Module to the master disk unit with an IDE  connection cable     Note     Setting the silicon disk unit as the master device involves a restrictions  For details  refer to the  manual for the silicon disk unit       To use the hard disk unit along with the dedicated CD ROM drive  IPC CDD 02  in a master slave  arrangement  refer to the manual for the dedicated CD ROM drive     Average Life of the Hard Disk Drive    The average life of the hard disk drive is 5 years or 20 000 hours of energized time whichever reached first     High temperature Detection 
4. Feature    Using the hard disk unit in a high temperature environment shortens the life of the hard disk  The hard  disk unit has a high temperature detection feature to detect an ambient operating temperature of 4743  C  or higher using the high temperature detection function of bus interface driver software  Use this feature  as a means of warning when the hard disk unit is being used at high temperature     When high temperature detection is not necessary  you can disable the high temperature detection  function by setting with the bus interface driver software  In that case  high temperature detection is not  performed     For details on this function  refer to the Bus Interface Driver User s Manual  PPC CPU686 MS  MU   separately priced            CONTEC  PPC HDD MS     PPC HDD MS  User s Guide    Copyright 2003 CONTEC CO   LTD  ALL RIGHTS RESERVED     CONTEC CO   LTD  February 2008 Edition  3 9 31  Himesato  Nishiyodogawa ku  Osaka 555 0025  Japan   Japanese http   www contec co jp    English _ http   www contec com  A 46 789  LYCY753   Chinese _ http   www contec com cn  02222008_rev5  07252003     No part of this document may be copied or reproduced in any form by any means without prior written  consent of CONTEC CO   LTD        
5. Hard Disk Unit for PC CPU Module  Compatible with MELSEC Q Series    PPC HDD MS  User   s Guide  CONTEC CO  LTD     Thank you for purchasing the PPC HDD MS  hard disk unit for PC CPU Module  Follow the  instructions in this guide to use the product     Notes     The hard disk drive can be easily damaged by electrostatic discharge  ESD   Use meticulous care  in handling the hard disk unit for moving or assembling     When using the hard disk unit  be sure to satisfy the conditions listed as its general specifications   For use in a severe environment  use the silicon disk unit instead     For use in a place subject to vibration or shock  use a set of shock proof brackets  PPC HBR 0O1   available as an option     As the hard disk unit has a limited life  be sure to back up important data recorded on the unit   To back up the contents of the hard disk  including the OS  you should use a commercial backup tool   such as Symantec Ghost      The hard disk drive  HDD  of this disk unit has not guaranteed use by continuation and continuation  power for 24 hours  When it is used by continuation operation and continuation power a life falls  extremely  In the case of a 24 hour operation system  use of our company silicon disk  SDD  is  recommended     The life of a hard disk drive changes with environment or operating conditions  As a  standard  power time  motor on time  below 333hours month  below 11 hours day   disk  access time is 20  or less  it becomes which for 20 000 hours  pow
6. ated in the operating environment     Pollution level 2 indicates the environment that generates only nonconductive pollutants while allowing accidental    condensation to cause temporary conduction      3 The hard disk unit may fail and cannot be used in an environment in which the air is compressed to over the    atmospheric pressure generated at an altitude of around 0 m     External Dimensions    Enhanced IDE interface connector                                                          130                                           27 4 4  je   a  er  PPC HOD  access     D   BUDE  so   YOE            N   IDE interface connector     For connection to  the PC CPU Module     Related Options  PPC SDD MS  Series  IPC CDD 02  PPC HBR O1    PPC CPU686 MS  MU                C4     UUUUUNUUUU0000000   MUUUUUNNUU00000000                                    D                          mm           Silicon disk unit  CD ROM   DVD ROM drive    Hard disk unit shock proof brackets   A set of upper and lower brackets     User   s Manual  PC CPU Module User   s Manual  Bus Interface Driver User   s Manual          CONTEC  PPC HDD MS     PPC HDD MS  User s Guide    Installing the Hardware  Precautions    Install the hard disk unit on the MELSEC Q Series base unit before it can be used    Before using the hard disk unit  be sure to mount the MELSEC Q Series base unit on the control panel  using screws  Do not use the base unit mounted on the DIN rail    For mounting the base unit  refer to the 
7. er time  or five years   or an early thing     Do not touch the interface connector of the hard disk unit     Before plugging to or unplugging from the connector on the hard disk unit  be sure to turn off the  power unit     CONTEC assumes no liability for any loss or destruction of data recorded by this product regardless  of the attribute of the causing fault or failure  Be sure to back up important data     Copyright    Copyright 2003 CONTEC CO   LTD  ALL RIGHTS RESERVED  No part of this document may be  copied or reproduced in any form or by any means without prior written consent of CONTEC CO    LTD    CONTEC CO   LTD  makes no commitment to update or keep current the information contained in  this document  The information in this document is subject to change without notice    All relevant issues have been considered in the preparation of this document  Should you notice an  omission or any questionable item in this document  please feel free to notify CONTEC CO   LTD       CONTEC       PPC HDD MS     PPC HDD MS  User s Guide    Regardless of the foregoing statement  CONTEC assumes no responsibility for any errors that may  appear in this document or for any results of using the product     Trademarks    MELSEC and CC Link are registered trademarks of Mitsubishi Electric Corporation  All other  brand and product names are trademarks of their respective holders     About the PPC HDD MS     This product is the hard disk unit dedicated to the PC CPU Module  PPC CPU686 MS 
8. riting Reading operation is less  than 20  of power on hours     General Specifications    Specification    8 to 90  RH  No condensation   5 to 95  RH  No condensation     Maximum wet bulb temperature 29  C         Vibration resistance Tested 10 times  for 45 minutes  in each of the X  Y  and Z directions in   during operation  conformance with JIS C0040    0 to 55 Hz  0 035 mm    lt With the optional hard disk unit fixing brackets attached gt    Tested 10 times  for 80 minutes  in each of the X  Y  and Z directions in  conformance with JIS C0040    0 to 57 Hz  0 075 mm    57 to 150 Hz  9 8 m s     Shock resistance  during operation  _ Tested 3 times in each of the X  Y  and Z directions in conformance with JIS  C0041  49 m s   11 ms    Operating ambiance No corrosive gas  Operating altitude 2000 m or less  3    Installation location Inside the control panel   Do not install the base unit on the DIN rail when the hard disk unit is used            Over voltage category  1 II or lower  Pollution degree  2 2 or less     1 The overvoltage category of a device indicates which distributor in the range from public distribution network to       machinery the device is assumed to be connected to  Category II applies to devices to which power is supplied from    fixed facilities  The surge voltage of those devices is 2500 V whose rated voltage is 300 V          CONTEC  PPC HDD MS     PPC HDD MS  User s Guide     2 The index indicating the degree to which conductive substances are gener
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Applica CI-1A User's Manual  Samsung SP-H03 Uživatelská přiručka  「医見書」 ソフ トの改正対応について  Samsung DVW-707/707P User's Manual  01-14.indd  BoConcept Model 280 Assembly Instruction  Mode d`emploi casserole à pression/autocuiseur  StecaGrid 8 000+ 3ph StecaGrid 10 000+ 3ph  P - Kälte Berlin  取扱説明書 - 日立の家電品    Copyright © All rights reserved. 