1. To next PL Anet device or terminator Wiring the logic outputs Tne 7way output terminal block provides four logic output connections Pins 5 to 7 G are used as the common return ground One wire can feed this ground to a bank of indicators or other devices The output works by switching the internal 5V reference supply through a 470 ohm resistor to the pin This presents a positive voltage when the output is turned on and an open circuit when it is turned off The switching is done using a transistor The resistor limits the current to a maximum 10mA to ensure the connected equipment does not draw more than the PL 8 can provide The output may be used in many ways to satisfy a range of interfacing applications It is important that the installer has a good working knowledge of interfacing circuits Incorrect application may result in damage to the equipment Typical applications include powering an LED indicator and switching solid state low current relays LAMPS MOTORS EQUIPMENT This product complies with the European Electromagnetic Compatibility directives 89 336 EEC amp 92 31 EEC NOTE Any changes or modifications to the equipment not approved by Allen amp Heath could void the compliance of the equipment Whilst we believe the information in this guide to be reliable we do not assume responsibility for inaccuracies We also reserve the right to make changes in the inter
2. Refer to the Help file for details on programming the PL functions Diagnostics fa fault is suspected check the two diagnostics LEDs on the underside of the PL 8 connector PCB Both the red and green LEDs should be lit once communication with the iDR is established If a fault is found first check for correct wiring If further assistance is required contact Allen amp Heath technical support Wiring terminals Phoenix type screw terminal connectors are used for connecting the external switches and logic to the PL 8 Make sure the wire ends are carefully stripped and inserted into the terminals Tighten the screws using a small slotted screwdriver To ensure interference free operation we recommend you use shielded cable Wiring the switch closure inputs The 7way input terminal block provides 4 switch input connections Pins 5 to 7 G are used as the common switch ground One wire can feed this ground to a bank of switches Two switches are shown wired in the diagram here The switch works by linking its connector pin to any ground G pin Use a contact closure such as a momentary press switch microswitch or relay to do this Low current switches may be used We recommend good quality sealed components for reliable operation The input pin is fed from the internal 5V reference supply through a 1k5 ohm resistor It uses an opto coupler to isolate the PL 8 from the connected equipment Approximately 1 2mA minimum current flows wh
3. system for daisy chaining remote controllers It is an RS485 serial connection that uses CAT5 STP cable to communicate between devices over long distances An RJ45 connector is used PL Anet only works with Allen amp Heath PL devices The port provides 20V DC to power the connected devices The iDR 8 port is shown here Number of devices The maximum number of PL devices that can be connected depends on their type and the distances involved You can connect up to 15x PL 8 units on a single PL Anet branch and up to 23 if you are using the optional PL 9 PL Anet hub Fewer may be connected if long distances or additional PL types are involved It is important that you check the possibilities first by referring to the PL Combinations Calculator spreadsheet available from the Allen amp Heath web site Description the PL 8 comes supplied with two PCB assemblies attached to a brushed aluminium wall plate This enables it to be mounted into a standard single gang wall backing box A UK EU European or US American size plate together with fixing screws is provided according to which version has been ordered The top PCB houses the circuit which interfaces to the iDR PL Anet control network Connection is made using two RJ45 type sockets one to receive PL Anet the other to pass it on to the next PL device in the chain If this is the last device in the chain then the terminator plug provided must be plugged in The lower PCB houses the screw te
4. ALLEN amp HEATH PL 8 Logic Controller AP5270 For PL 8 units manufactured after November 2004 User Guide The PL 8 is part of the Allen amp Heath PL Series of wall plates and remote controllers available for the iDR 4 and iDR 8 audio mix processor systems It is a small module comprising two circuit cards This can be locally mounted in a single unit wall box using the standard UK EU or US face plate supplied The PL 8 provides four contact closure switch inputs and four transistor logic outputs for external equipment control Their function is programmed using the iDR System Manager software The combination of switch input and logic output makes the PL 8 ideal as a multi function remote controller in installed systems The unit can interface to a variety of devices including alarm systems room divider switching paging controls event triggers and various custom switches and indicators Control can be distributed where it is needed The PL 8 interfaces via the Allen amp Heath PL Anet serial network Multiple PL 8 units can be daisy chained using CAT5 cable along with other PL Anet devices such as the PL 3 and PL 4 wall plates PL 6 fader controller and so on For information on the full range of PL products available visit our web site http www allen heath com i Internal view shown ALARM OVERRIDE ALLENGHEATH gt PL Anet EE E EEEE OC CBABCCCC 0 e 5 AUDIO ROOM DIVIDER S
5. WITCHES PAGING MIC CUSTOM SWITCHES AND INDICATORS SELECT AND TALK SWITCHES poe TERMINATION The Application The diagram above shows an example of a remote control network using an iDR 8 The iDR 4 could also be used Various PL devices are installed in different parts of the building for example PL 3 and PL 4 wall plates for room volume control and source select PL 6 fader panel for remote mixing in a conference room and PL 8 units for distributed remote control The PL 8 could be wired to a fire alarm system to automatically mute the system or override it with a pre recorded evacuation announcement to simple wall plate switches for local volume control or event configuration changes to paging panels for zone select and talk switching to room divider panel microswitches to automatically reconfigure the system when rooms are combined to control or be controlled by equipment such as video players and jukeboxes for interractive local sound in museums theme parks and so on The devices are daisy chained together using CAT5 cable The last unit in the chain requires a terminator provided PL 8 User Guide AP5270 issue 3 1 IMPORTANT Note PL 8 Units manufactured prior to November 2004 were fitted with 5way terminal blocks with a single ground terminal rather than the 7way version used on later models as described below If you require any more information on the earli
6. cal contact with a grounded back box The same applies to any exposed metal surfaces used within the system PL Anet wiring Use flame retardent CAT5 STP shielded twisted pair cable terminated with RJ45 connectors Do not use UTP cable We recommend the multi stranded rather than solid conductor type The connection follows the EIA TIA 568B wiring colour scheme Ensure all ports and cables in the system are wired to this scheme Connecting to an iDR unit Tne iDR unit communicates with the PL 8 using the PL Anet port This serial connection can be daisy chained through several PL wallplates as shown Make sure you plug the PL Anet IN and OUT sockets correctly End of chain termination As with any RS485 system the last PL device needs to have a terminating resistor fitted to its output port Each PL 8 is shipped with a terminator plug already fitted in its PL Anet output socket Leave this fitted only if the unit is the last in the chain Programming the controls iDR system Manager software version V3 1 or later is required Check the Allen amp Heath web site for the latest software Ensure that the iDR PL Anet port is active Its green active LED should be lit If not use the iDR System Manager software Communications Option menu to activate the port Plug in the PL Anet cable The iDR System Manager screen should display icons for each PL device it recognises If you do not have the iDR available you can configure the software off line
7. en connected to ground Combined switch and cable resistance should not exceed 1k ohm for the switch to activate INTERNAL PL 8 CIRCUIT 1 OF 4 SHOWN LED INDICATOR TYPICALLY 6mA Specification In Out Connectors Phoenix 7way screw terminal blocks For permanent bare wire connection Switch Inputs 4x opto isolated switch closure inputs 5V DC through series 1k5 ohm resistor Switch closure connects pin to ground Maximum current when switched 1 2mA Maximum switch cable resistance 1k ohm Switch types Momentary action Microswitch Relay contact Custom interface Logic Outputs 4x transistor logic outputs Uses internal PL Anet supply ON 5V DC through series 470 ohm resistor OFF open circuit Output voltage depends on current drawn Maximum current per output shorted 10mA Output capability LED indicator Solid state relay Custom interface Communication RS485 based PL Anet serial port RJ45 input and output connectors Maximium 15x addresses per PL Anet branch Configuration iDR System Manager software V3 1 or greater Refer to the software Help file Separately configure switches and outputs Input switch function Volume up down Mute on off Patch recall Monitor select Logic output function Static on off Mute status Soft switched Patch recalls Scheduled events Power Supply Internal 5V DC from PL Anet 20V supply Minimum PL Anet voltage at PL 8 11V Maximum logic output 40mA all shorted
8. er models please contact Allen amp Heath technical support AG5258_1 PL 8 TOP PL 8 early type connector block PL ANET DR LINK AUDIO IN AUDIO OUT CAUTION 20V DC TO AVOID DAMAGE ONLY CONNECT DIGITAL EXPANDER COMPATIBLE REMOTE CONTROL EQUIPMENT TO THE PL ANET PORT CUSTOM WIRING ino OOOO DDoresl LOGIC OUT SWITCH IN 1234GGG IN 5 7 OUT IN C GND WLLL iY a l CUSTOM WIRING FROM PREVIOUS PL DEVICE TO NEXT PL DEVICE OR TERMINATOR Order code PL 8 UK UK single backing box A Observe the local standards which may apply to the installation regarding the grade of cable and installation methods A To ensure operator safety ensure that any exposed metal face plates and surfaces are correctly bonded to ground Do not install the equipment where it is subject to moisture heat or vibration A Connect this equipment to the Allen amp Heath PL Anet port only Do not connect it to Ethernet DR Link or other RJ45 ports A When wiring to custom components and external equipment care must be taken to ensure each part operates within its specified capability This work should be carried out by competent installation personnel only A Before powering up the system make sure all the wiring is inspected and continuity tested This is important as wiring errors may result in damage to the equipment PL Anet is the proprietary Allen amp Heath
9. est of further product development Copyright 2005 Allen amp Heath Ltd All rights reserved PL 8 User Guide AP5270 issue 3 SWITCH From iDR or previous PL Anet device
10. rminal blocks which are used to wire to switches indicators relays and other custom controls within the installation One block connects to up to four switches the other provides up to four logic outputs Order code PL 8 US Order code PL 8 EU Plate part number AA5277 Plate part number AA5276 Plate part number AA5275 US part number AA5220 UK UK EU a N lal e gt 86 60 3 lt 113 5 J 72 x 72 x 35 mm 86 mm 80 mm 69 mm PL 8 User Guide AP5270 issue 3 a 12345678 Hook Under neath O O GiB BiG Br Br ww fg OOO caso QOOOOO000 B Mi i 5 2222 OOOOOO PL Anet TERMINATOR PLUG SWITCH _ INTERNAL PL 8 CIRCUIT 1 OF 4 SHOWN OPTO a PL 8 User Guide AP5270 issue 3 Installing the PL 8 Mount the assembly into a single gang backing box located in a wall or suitable furniture If necessary it may be installed in a hidden location such as a ceiling void or cupboard as it is not necessary for the operator to have access to the module Minimum recommended internal box depth is 32mm We recommend that you provide enough space in the cavity behind the box to allow a service loop for the wiring to the module A Grounding metal plates Ensure that the metal face plate is correctly grounded to ensure safety The plate should be connected to a local safety ground Use a ground wire or physi
Download Pdf Manuals
Related Search
Related Contents
Smeg LSE451 Instructions for Installation and Use Messverstärker und Regler Montage- und Biodinamica (Libro) - Prof. Paolo Bellavite SHOW INFORMATION: A-Z GUIDE Whirlpool MT8116XE User's Manual Antonio Blecaute Barbosa GE EANA Installation Guide Bedienungsanleitung Pushphone Copyright © All rights reserved.