1. ccccccccccccessssesssecececsesesecneseceeecessesesaeaeeeescesseseaaeaeeeeecssseseaeaeeeesens 8 HCG D DISDISV nee t eee roe Pe Ene ne a Pe ee 9 Connecting to Rain Sensor uei eerie eed anus ua eal eee dre eode eoo Saes eoa eee eoe d eub eed SAE ESEE Eaa 10 CONTROLLER QUICK REFERENCE GUIDE eese nennen nnne enne nn nnns inttr entente rsen innen en 11 OpenSprinkler Firmware Update ccccssccccccessssssessecesecseeesesneaecesecsseesesaeaesesecsseeesaeaeeeeeessseseaeaeeeeeesseeeeea 12 Upload a Precompiled Firmware sees nennen enne aiee EEE oaae di aniidae 12 Driver InStallatON s t eR Re Pee HEINE R vede Rees erste Den eee Ren ER Puente sa 13 Compile and Modify the Source Code sessi nn tn nn nass ess n sitis s assa sena nan 14 Page 2 Hardware Interface The interface of the controller is shown in the pictures below The 24VAC power jack switch and USB connector are on the left side the three push buttons and the Ethernet connector are on the right side the COM common terminal and screw terminals for connecting sprinkler wires are on the bottom Note that the two ports on the COM terminal are internally wired together so either can be used as the common wire There are also a rain sensor connector and zone expansion connector Official Fully Assembled v2 0s HH Tre Pinouts microSD slot Buttons USB for re programming LUIS E ere gees an
2. GNO MICROSD SOCKET EXTOUT aE Page 15
3. d 5V output gt Ethernet E Jack 24VAC gt Zone e Er a N z 1 Expansion eut Connector COM Wire Stations 1 8 Rain Sensor Terminal DIY v1 42u Opens 42u gt eye RTC battery OHIO CHRIS e lt Buttons Power Switch E e G Pinouts USB for re programming and 5V output 24VAC Rain sensor e v 4 Common stations 1 8 Expansion Board Wire Connector Page 3 Power Supply Requirements The controller uses a standard 24 27V AC note that the output is AC not DC sprinkler transformer Since AC transformers are not regulated the output may vary anywhere between 22V AC to 29V AC The current rating should be at least 500mA 12VA Sprinkler transformers can be purchased online search for sprinkler transformer or 24V AC transformer or at local home improvement stores You can also buy a cheap off the shelf sprinkler timer which usually comes with a transformer Warning DO NOT plug 24VAC into the COM port or the Rain Sensor port Doing so may damage your transformer or the controller We recommend using a permanent marker to mark the screw terminal pieces to help you easily identify the two Also to reduce the chance of damage due to power surge please use a surge protector e Update from version 2 1 the 24VAC terminal has been changed to an orange colored one with a different pin spacing This can help prevent mistakes in plugging in power After connecting the power supply
4. d the NetGear WNCE2001 both of which have built in WiFi Client Adapter mode They are pocket size and inexpensive around 25 bucks Also you may power these adapters directly through OpenSprinkler s USB port Besides any router that supports DDWRT also works Port forwarding To access the controller from an outside network you need to set up Port Forwarding on your router This allows an external request to be mapped to the controller To do so you need to find out the external IP WAN IP and forward Port 80 to OpenSprinkler s IP address Please refer to your router s user manual Note that most modern routers support dynamic DNS service such as dyndns web com which eliminates the need to remember your external IP Also if necessary the HTTP port number can be changed in options Button Functions Normal Operations After the controller starts normally the buttons are assigned the following functions e Click B1 to display controller s IP and port number e Click B2 to display gateway router IP Page 8 Click B3 to change the board displayed on the LCD MC master controller E1 ext board 1 and so on Hold B2 to disable controller operation all stations will be closed Hold B1 to enabled controller operation back to normal Hold B3 to restart the controller LCD Display During normal operation the LCD displays the following information O O Current time is shown on the first line Stat
5. ion status is shown on the second line If a station is on the LCD will display a 3 character animation oO to indicate that it s open The master station is marked M If you have zone expansion boards click button B3 to cycle through all available boards Network status is shown as a single character icon at the end of the second line It tells whether the network is on or temporarily lost based on ping results from your router If the network is lost for more than 5 minutes the controller will automatically reconnect You can disable the automatic reconnect feature in options On firmware 1 8 3 no icon will be displayed if network is on otherwise a question mark will be displayed On firmware 2 0 3 an SD card icon will be displayed if a microSD card is detected 11 18 Mon 03 1 12 Mon 89 17 Bus c Page 9 Connecting to Rain Sensor From OpenSprinkler v1 4 there is an on board screw terminal for connecting to an off the shelf rain freeze sensor You can also select the rain sensor type normally open or normally closed in controller options Connect the two wires from the rain sensor to the screw terminal and then set the Use Rain Sensor option to Yes When rain is detected the controller will automatically shut down all stations If you want to bypass ignore the rain sensor reading just turn that option off Page 10 CONTROLLER QUICK REFERENCE GUIDE Change the controller options settings e Hold B3 while star
6. n Use DHCP yes to enable DHCP i e obtain a dynamic IP from your router no to disable DHCP and use static IP Static IP is recommended as the controller will have a fixed IP address and is faster to reconnect Static IP Default 192 168 1 22 Only available when Use DHCP option is set to no The IP address spans four fields ip1 ip2 ip3 and ip4 Keep clicking B3 to access all fields If you use Static IP you must set the correct Gateway IP as well Gateway IP your router s IP Default 192 168 1 1 Only available when Use DHCP option is set to no HTTP Port can only be set via the web interface Default 80 Auto Reconnect automatically reconnect upon network failure Default on Page 5 Exp Boards number of zone expansion boards Default O Sequential sets the controller s execution mode yes to select sequential mode where station runs are serialized no to select concurrent mode where multiple stations can run simultaneously Default yes Station delay delay time up to 240 seconds between two consecutive stations Default 0 Master station Master is a station that turns on when other stations are running It can be used on a water pump or main valve such that the pump or valve will turn on automatically when any other station is open The default value is 0 which means no master station A value larger than O selects a master station any stations from 1 to 8 can be assigned as a master station Master on adju
7. n e For OpenSprinkler 1 x and 2 0 you need to install USBtinyISP driver e For OpenSprinkler 2 1 you need to install USBasp driver In general you do not need to run any executable file from the driver installation folder Instead plug in a USB cable to OpenSprinkler for OpenSprinkler 2 1 and above press and hold pushbutton B2 while plugging in a USB cable then release B2 within 2 seconds and let Windows detect the device It will report that driver is not found Next go to Device Manager identify the USB device USBtiny or USBasp right click the on the device and select Update Driver then select Browser My Computer Page 13 for Driver Software and provide the path to the driver files folder This should allow you to successfully install the driver Windows 8 and 8 1 can be very tricky to work with due to the driver signature enforcement The general approach is to disable driver signature enforcement first and then follow the same procedure above to install driver If you are lost Google Windows 8 USBtinyISP or Windows 8 USBasp and you should find some solutions online In the worst case if nothing works try the Rayshobby pre configured VirtualBox image below This will create a virtual Linux in your host Windows system It can pass through USB devices directly to the virtual OS thus avoiding the driver installation issue Compile and Modify the Source Code If you wish to modify the OpenSprinkler sou
8. rce code and customize the software please refer to the OpenSprinkler website http rayshobby net Page 14 HO1PTH RELAY 2650 SO_SEL na ai 2N7002 a Latch D EN ETHER D ND HO GNO D RAINSENSE LCD BKLIGHT LCD UO RELAY Power Supply Ic8 4 PCINTB XCKa TO PRA PCINTS CLKO T1 PBi PCINT1 INT2 AIN _PB2 PCINT11 0CBA AINi PB3 PCINT1 2 0C0B SS PB4 PCINT13 MOS1_PBS PCINTL4 NISO PB6 PCINT15 SCK PB RESET vce GND XTAL2 XTAL1 PCINT24 RXD8 PD PCINT25 TXO _PO1 PCINT26 INT _PO2 PCINT27 INT1_PO3 PCINT28 0C18 PD4 PCINT28 0C16 PDS ATNEGA644 2GPU GNO PCINT ADCE_PAG PCINTL ADC1_PAL PCINT2 ADC2_PAZ PCINT3 ADC3_PAZ PCINT4 ADC4 _PA4 PCINTS ADCS_PAS PCINT6 ADC6 Ph PCINT7 ADC7_PA7 AREF GNO AYCC PCINT23 TOSC2_PC7 PCINT22 TOSC1_PC46 PCINT21 TDI PCS PCINT20 TDO PC4 PCINT1S THS PC3 PCINT18 TCK_PC2 PCINT17 SOA_PC1 PCINT16 SCL_PC PCINT3 0C2B ICP_PO6 PCINT31 0C2A_PO7 HARDWARE SCHEMATICS LCD Display RZ us GNO 82 rm 83 rm GND RAIN LEDS RESET CLKQUT UDOTX TPOUT TPOUT USSTX EN P UDORX TPIN TPIN USSRX RBIAS yooasc asci asc2 yssasc YOOPLL USSPLL GNDENC28J6 SP 32KH2 SCL ucc Soa SQU INT VBAT GND NC BAT1 nea CR1228 NCS GND Ualve Driver p4 NC Qn cs QB DI ac ucc ao SCK QE GND Qr Da Qs RSU GH H SHIELD SHIELD RPR SHIELD PH SHIELD
9. re program the fuse bits on OpenSprinkler v1 2 and above as they have built in USB programmer and are already programmed with the correct fuse bits Upload a Precompiled Firmware The recommended method for updating firmware is now through using the GUI based OpenSprinkler Firmware Updater You can download the updater software following the links below e Firmware Updater Windows 32 bit Windows 64 bit e Firmware Updater Mac OS e Firmware Updater Linux 32 bit Linux 64 bit Page 12 Note if you see messages such as avrdude warning cannot set sck period Please check for usbasp firmware update and avrdude error usbasp_transmit usbasp_control_msg sending control message failed these are normal and can be safely ignored These warnings errors have to do with the behavior of the bootloader upon reset They do NOT mean the firmware upload has failed Mac Users if you encounter an error Application is damaged and can t be opened you need to temporarily change a Security and Privacy setting in System Preferences See the details in this work around Driver Installation Linux and Mac users do not need to install any driver The operating system automatically support the OpenSprinkler USB programmer Linux users need to run the Updater software in sudo mode or alternatively add the USB device VID PID to etc udev rules d Windows Users need to install USBtinyISP or USBasp driver depending on your hardware versio
10. re stored in EEPROM which are preserved through power loss Self test This is activated by holding B1 while starting the controller The self test mode opens each station for 10 seconds in turn including stations on the zone expansion boards if you have This is useful for quickly checking if all stations are working The self test time can be changed in options Reset On OpenSprinkler 2 0 and prior versions holding B2 while starting the controller provides a short cut to the Reset option Select yes and then hold B3 a hardware reset will be triggered and the controller will recover to default settings From OpenSprinkler 2 1 holding B2 while starting the controller will enter bootloader mode which allows you to flash the microcontroller with a new firmware To enter Reset as above you can use the Reset option Network Connection Choices Wired Connection OpenSprinkler has a built in Ethernet connector which can be directly plugged into your router via a standard RJ45 Ethernet cable WiFi Connection To use OpenSprinkler on a WiFi network you need a wireless adapter or repeater To do so connect OpenSprinkler to the adapter repeater using an Ethernet cable then configure the adapter repeater to log on to your WiFi Page 7 network Note that USB WiFi dongles will not work The diagram below shows an illustration There are many available WiFi adapters repeaters on the market We recommend the TP LINK TL WR702Nan
11. slide down the power switch The LCD should turn on and start displaying messages Wire Sprinkler Valve A sprinkler valve has two wires Connect one wire to the COM Common terminal either of the two ports and the other wire to an individual station terminal S1 S8 For multiple valves one wire from each valve is combined together and goes to the COM terminal and the other wire of each valve goes to its corresponding station terminal If you are not sure ask a landscaper or go to a home improvement store to ask for help Page 4 Set Up Options The controller is programmed with a list of options Most of them do not need to be changed Change the controller options settings Turn off the controller Hold pushbutton B3 while starting the controller until you see the message Setup Options Click B3 to cycle through all available options and click B1 or B2 to increase or decrease the value of each option Note that some options can only be set via the web interface and cannot be changed using buttons Once you are done hold B3 again until the controller restarts Your changes are now Saved and applied List of Options Firmware 1 8 3 and 2 0 3 The latest firmware version is 1 8 3 for 1 x hardware and 2 0 3 for 2 x hardware The complete list of options are described below Time Zone select your time zone used for NTP time sync and effective only after reboot NTP Sync automatic time sync via NTP Default o
12. st adjust the time 0 to 60 seconds that master will turn on when a station opens For example 5 means the master will turn on 5 seconds after a station opens Default O Master off adjust adjusted the time 60 to 60 seconds that master will turn off when a station closes For example 5 means the master will turn off 5 seconds before a station closes Default O Use Rain Sensor allows a rain sensor to stop the water schedule when rain is detected Default no which means rain sensor reading is ignored Rain sensor type normally open or normally closed 9 o Water time percentage of water time from 0 to 250 Default 100 This provides a way to globally scale up down water times For example if a program normally waters each zone for 10 minutes and if the water level is changed to 150 then the actual water time is 15 minutes Self test Time the time up to 255 seconds to open each station during self test Ignore password select yes to disable password on the web interface Device ID sets the last byte of the controller s MAC address Default O LCD Contrast sets the contrast of the LCD display Hardware v2 x only LCD Backlight sets the brightness of the LCD backlight Hardware v2 x only NTP server IP sets the server used for NTP sync default 204 9 54 119 Hardware v2 x only Page 6 e Reset all yes will restore the controller to default settings warning water schedules will be erased All option values a
13. ting the controller e B3 cycle through options e B1 increase B2 decrease values e Hold B3 again to save and restart Station Self test 10 secs each e Hold B1 while starting the controller Normal Operations e B1 IP and port number e B2 gateway router IP e B3 cycle through MC master controller E1 ext board 1 e Hold B2 disable controller all stations will be closed e Hold B1 enabled controller e Hold B3 to restart the controller Reset Default Settings e Hold B2 while starting the controller B1 B2 select yes Hold B3 Page 11 OpenSprinkler Firmware Update The OpenSprinkler firmware is regularly updated to include new features and functionality You can update the firmware at any time by reflashing the microcontroller MCU The source code is completely open and free You are welcome to modify it and share your contributions through GitHub Warning Uploading a new firmware will erase your program settings and restore options to default values Preparation e You need a regular size Male A to Male B USB cable most printers use this type of cable e If you own OpenSprinkler v1 0 or 1 1 you need an external ISP programmer FTDI cable no longer works due to the size of the new firmware In addition you need to run the following command to re program the fuse bits avrdude c usbtiny p m328p B 250 F U lfuse w 0xff m U hfuse w 0xdl m U efuse w 0x06 m Only do this if you own v1 0 or v1 1 Do not
14. we A RARO Open Sprinkler User Manual RAYSHOBBY NET Ray s DIY Electronics Hobby Projects Page 1 Contents RAYSHOBPBY NET austero n ant tese iei eina eec siga e nda shaadi sued anion edge deos 1 Hardware Interface orte rite essi ai So cai iai coto dies stance dece Ree zt a extpe etat sa soraia 3 Official Fully Assembled V2 0S cccccesessscecececessessaececececesseeaseeeeeeecesseseeaeseeeessussesaeaeseeeseseusesaaaeeeeeeesesegs 3 Pea v 3 Power Supply REQUIFEMENKS cscccccccessssessssecececessesesaesecececesecaaeaeeeeecesseseaaeseceeecesseseaaeseeesecesseseaeaeeeeeens 4 Wire Sprinkler Valve cetero ae eoe tetti ene R edet eee sunu su denote ut aestuat oes RMC catar evan ui pent ux cas ada 4 Set Up Options mme 5 Change the controller options settings ccccccessccssscccsseceesceceeeccssecessseceeseecasecesaececseeceseecesaeeecaaecensees 5 List of Options Firmware 1 8 3 and 2 0 3 cccccccccsssseceesssseceessseececsesaeceesessececsesseeecsesaeeecsesaeeeesesaeeeeneaaes 5 Ng lr E 7 hike 7 Network Connection Choices aaae aa aeo eaaa iaa anna trente snnt nnne trennen 7 Wired COMME CEO e vadias 7 WiFi CONNEC Ohenne 7 elamieiQ I Ito a sos ces N E AE AE EARE EA EAEE TEE E EEE EE A E AET E ET 8 Button Functions Normal Operations

Download Pdf Manuals

image

Related Search

Related Contents

GP Batteries NiMH rechargeable batteries ReCyko Accu AAA  GSM SMS Alarm & Dialer -- Ultra Version! An Advanced  DS-12 - Nikon Passion  Netviewer Benutzerhandbuch  Chicago Electric 66891 User's Manual  NEC Multeos M461 DST Touch  Elation Professional DMX-512 User's Manual  Supermicro SuperChassis 936A-R900B  SLV-N51  取扱説明書 - フジ医療器  