Home

ICX30-HWC User Manual

image

Contents

1. LAN Configuration IP Address Description IP address of the ICX30 HWC on the LAN Subnet Mask Subnet mask of the ICX30 HWC on the LAN Default Gateway Pass Thru IP Gateway of the ICX30 HWC on the LAN IP address on the LAN to connect to through the ICX30 HWC DHCP Enable or Disable DHCP server of the ICX30 HWC DHCP Client Range 1st DNS IP address range for DHCP server First domain name server IP address 2nd DNS Second domain name server IP address Page 26 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M 2 4 3 Advanced Setup Configuration Webpage User Manual The Advanced Setup tab includes the setup for port forwarding serial port digital I O and analog input ports RadioLinx Status System Up Time System Time IMEI Board F W Version Cell Engine Version Network Registration PIN Status Cell Engine Temp GPS WAN Status Disconnect Count LAN mcs Netmask MAC Received Packets Sent Packets Serial Received Bytes Sent Bytes Cellular Data Usage Current Day Current Month Previous Day Previous Month Network Interface Advanced Setup Administrator Port Forward MAC Filtering Oday Oh im 5t 1970 01 01 00 01 ia INS 990002189916495 SNMP ICX30 1 1 49 201 Serial Part 03 001 eria o Not registered VPN Tunnel IPSEC The MS is not sear reg
2. 4 GSM Communication AT amp T 43 4 1 R OIP Ae ETC pr Ui MET 43 4 2 aD Tc 43 4 3 Spo TP H ees 44 4 4 EDOE sets um E pu bu dmm D E Me m D EE 44 4 5 Clan enc p LA an ce ee eee 44 5 CDMA Communication Verizon 45 5 1 EVDO RE 45 5 2 p cre Pc 45 ProSoft Technology Inc Page 5 of 64 June 22 2015 Contents User Manual 5 3 Security cesses nnne nnns 6 Ethernet IP Support 6 1 Creating a New RSLogix 5000 Project 6 1 1 Adding a 1756 ENBT to the Project 6 1 2 Ethernet Bridge Network Setup 6 2 Importing the AOI 6 3 ICX30 HWC Controller Tags 6 3 1 ICX30 CONTROL eic nana 6 3 2 ICX 30 STATUS saaki a tacueee 6 3 3 je ecol c 6 3 4 je 650209 EE 6 3 5 EX 30 GP cm E 6 3 6 ICX 30 UTILE acto reato ees teens 7 Support Service amp Warranty TA Contacting Technical Support 7 2 Warranty Information Index Page 6 of 64 ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Start Here 3C Cellular M2M User Manual 1 Start Here In This Chapter About the ICX30 HWC Industrial Cellular Gateway 7 se PACKAGES COMIC IIS tese osea md kkk Cotta denote kalk 10 4 System Requirements
3. PS attached in HSDPA HSUPA capable cell WAN Status Connected IP 166 131 66 26 Sent Packets 1 KBytes Received Packets 384 Bytes Link Time Oday Oh 2m 40s Disconnect Count 0 LAN IP 10 1 3 186 Netmask 255 255 255 0 MAC 00 0d 8d a4 00 1a Received Packets 39866 KBytes Sent Packets 199621 KBytes Serial Received Bytes 0 Sent Bytes 0 Cellular Data Usage Current Day 13 KB Current Month 50 KB Previous Day 25 KB Previous Month 0 Bytes Page 22 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M System Up Time System Time IMEI IMSI ICC Phone Number Board F W Version Cell Engine Version MEID CDMA only Network Registration PIN Status Area Information Cell Engine Temp GPS Signal Level Network WAN Status IP Sent Packets Received Packets Link Time Disconnect Count LAN IP Netmask MAC Received Packets Sent Packets Serial Received Bytes Sent Bytes Cellular Data Usage Current Day Current Month Previous Day Previous Month ProSoft Technology Inc June 22 2015 Configuration Webpage User Manual Description Amount of time the ICX30 HWC has been active since the last power cycle or a reset Current date and time of the ICX30 HWC International Mobile Station Equipment Identity number International Mobile Subscriber Identity number Integrated Circuit Card identifier Unique to each SIM card Phon
4. ProSoft TECHNOLOGY Where Automation Connects ICX30 HWC 2 Industrial Cellular Gateway n 3G Cellular M2M SIGNAL STRENGTH METEC ANS O lO mC ar RadioLinx Industrial Cellular Gateway ICXGO HWC ETHERNET SERIAL 10 24 VDC Le 1 June 22 2015 USER MANUAL Your Feedback Please We always want you to feel that you made the right decision to use our products If you have suggestions comments compliments or complaints about our products documentation or support please write or call us ProSoft Technology 5201 Truxtun Ave 3rd Floor Bakersfield CA 93309 1 661 716 5100 1 661 716 5101 Fax www prosoft technology com support Oprosoft technology com ICX30 HWC User Manual June 22 2015 ProSoft Technology is a registered copyright of ProSoft Technology Inc All other brand or product names are or may be trademarks of and are used to identify products and services of their respective owners In an effort to conserve paper ProSoft Technology no longer includes printed manuals with our product shipments User Manuals Datasheets Sample Ladder Files and Configuration Files are provided on the enclosed DVD and are available at no charge from our web site http www prosoft technology com Content Disclaimer This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications It i
5. Static IP address Subnet Mask and Gateway address for each device you plan to install Obtain this information from your system administrator Page 10 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Start Here 3G Cellular M2M User Manual 1 4 Power Requirements The ICX30 HWC accepts voltages between 10 and 24 VDC 300 mA 12 VDC 150 mA 24 VDC with an average power draw of 6 watts or less A detachable power connector comes with the radio as shown below The connector terminals are labeled positive DC connection and DC ground connection The AC to DC power supply adapter may be used DC power wires must be less than 2 meters in length to meet regulatory requirements Important When wiring the power connector be sure to observe the proper polarity markings on the power connector Improper connector wiring can cause serious damage to the ICX30 HWC which will not be covered under the ProSoft Warranty The power connector ProSoft P N 002 01 16 and wire installation tool ProSoft P N 357 0061 are shown in the following graphic The wire installation tool is helpful when installing wires into the spring loaded contacts inside the power connector 1 Touse the wire installation tool insert it into the connector as shown 2 Press down on the installation tool to use it as a level which opens the connector s contacts to insert a wire A properly wired connector is shown ProS
6. 111 111 111 111 Analog Input Apply Changes Reset 5201 Truxtun Ave 3rd Floor Bakersfield CA 93309 1 661 716 5100 GRE Tunnel Runt Tunnel Destination Address Tunnel TTL Routing IP Group Netmask Add Entry button Delete Entry button Apply Changes button Reset button ProSoft Technology Inc June 22 2015 Description Enable or Disable GRE Tunnel Enter the Tunnel Destination Address Time a packet can remain on the network before being discarded Alows the configuration of multiple routes optional Enter a specific IP Group Enter a Netmask for the IP group Adds the IP Group and Netmask to the Routing table Deletes selected entries from the Routing table Click when you are satisfied with your GRE Tunnel settings Resets all fields back to empty values Page 33 of 64 Configuration Webpage User Manual Digital I O ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M There are two digital input output terminals on the ICX30 HWC SMS text messages can be sent to up to five phone numbers upon the status change of a digital input Digital I O No 1 SMS Alarm Entry 1 SMS Alarm Entry 2 SMS Alarm Entry 3 SMS Alarm Entry 4 SMS Alarm Entry 5 SMS Alarm Text Low High No 2 Toggle Output Status Analog Input Description Input or Output Phone number 1 to send SMS text alarm Phone number 2 to send SMS text alarm Phone number 3 to send SMS text alarm Phone number 4 to send SMS text alarm
7. iinneenennnnnnennnene nan nnnnnnnaa annan 10 Power Requirements isinara ioneina DA UUT E 11 1 1 About the ICX30 HWC Industrial Cellular Gateway The Industrial Cellular Gateway provides secure wireless Ethernet and serial connectivity to remote devices such as PLCs RTUs DCS systems and instruments over 3G cellular services Remote devices can be accessed using secure VPN tunnels over Internet connections The ICX30 HWC is ideal for accessing remote equipment for maintenance programming remote data collection SCADA and machine to machine M2M applications Key applications include utilities manufacturing automation oil and gas SCADA telemetry Homeland Security and asset monitoring ProSoft Technology Inc Page 7 of 64 June 22 2015 Start Here User Manual ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M Mobile Originated to Mobile Terminated Cellular to Cellular Wireless Network Provider Internet Cellular Modem PC or PLC LAN to Mobile Terminated Network to Cellular Wireless Network Provider Company LAN 7 f Wo Y aec mi Router Ethernet Serial Connection Cellular Router Modem ns 232 serial B Connection i PC with port PLC Internet redirect software Page 8 of 64 ProSoft Technology Inc June 22 2015 June 22 2015 ICX30 HWC Industrial Cellular Gateway otart Here 3C Cellular M2M User Manual 1 1 1 Specifications Radio Cellul
8. M2M Description Service port number of the VPN server IP address of the VPN server Optional configuration file for the VPN VPN authentication that issues certificates for VPN Secure Internal Communication SIC and users Issued by a certificate authority as proof of identity Password to corresponding client certificate GRE tunneling provides full connectivity between two sites without using encryption GRE tunneling supports multiple routes and multiple endpoints over a single GRE tunnel GRE Tunnel Page 32 of 64 Local IP 192 168 1 250 Subnet 255 255 255 0 WAN IP 166 131 66 25 Local IP 172 20 0 211 Subnet 255 255 255 0 WAN IP 166 131 66 25 Prosoff Radiolinx 125 23 UE Routing IP Groups optional Remote LANs ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Configuration Webpage 3G Cellular M2M User Manual New configurations are saved on a micro SD card if inserted allowing modem reboot or configuration transfer via micro SD to another radio without loss of configuration data fields RadioLinx Status GRE tunnel Run Tunnel Destination Address Tunnel TTL Routing Optional ProSoft Technology Inc Network Interface Advanced Setup Administrator Port Forward MAC Filtering Enable Disz Dynamic DNS 0 0 0 0 SNMP Y Serial Port IP Group VPN Tunnel IPSEC VPN Tunnel OpenVPN GRE Tunnel Digital I O m
9. Power cycle every X number of hours Optional User name for connection assigned by the carrier upon reboot Optional Password for connection assigned by the carrier upon reboot PAP Password Authentication Protocol CHAP Challenge Handshake Authentication Protocol PAP amp CHAP Both are used Helps ensure a mobile ICX30 HWC stays connected Enable or Disable Starting day of billing of each month With Data Block enabled the maximum number of megabytes MB or gigabytes GB of 3G data usage before 3G communications are shut down until the next Start Day Enable or Disable Allows pinging two servers at set intervals If fail count is reached on both servers the ICX30 HWC disconnects from the WAN and cycles power Trial interval time in seconds Maximum number of ping failures before reset IP address of the 1st server to ping IP address of the 2nd server to ping Page 25 of 64 Configuration Webpage User Manual LAN Configuration ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M ICX30 HWC LAN configuration RadioLinx Status LAN Configuration IP Address Subnet Mask Default Gateway Pass Thru IP DHCP DHCP Client DHCP Client Range ist DNS 2nd DNS Network Interface Advanced Setup Administrator 10 1 3 186 10 1 3 1 Disable IP Address MAC Address Name 192 168 0 1 192 168 0 10 168 126 63 1 168 126 63 2 Apply Changes Clear
10. RTU or ASCII Client mode only WAN IP address of Modbus slave radio Client mode only Slave ID start Client mode only Slave ID end Description Master ICX30 HWC serial port is connected to a DF1 master Slave ICX30 HWC serial port is connected to one or more DF1 slaves Master mode only Defines which DF1 service port to listen to Master mode only IP address of a remote ICX30 connected to a DF1 slave Master mode only DF1 slave ID of remote DF1 slave Slave mode only IP address of remote ICX30 connected to a DF1 master Slave mode only Service port of remote ICX30 connected to a DF1 master ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M VPN Tunnel IPSEC Configuration Webpage User Manual VPN Tunnel Internet Protocol Security IPSEC It consists of protocol s used for authentication and encryption VPN Tunnel IPSEC Gateway Client Local Group Local Group FQDN User FQDN Remote Group Remote IP Remote Group IP Remote Group Subnet Remote Group FQDN Aggressive Mode Pre Shared Key Phase 1 and 2 DH Group Phase 1 Encryption Phase 1 Authentication Phase 2 Encryption Phase 2 Authentication VPN Tunnel Open VPN Description Disable Client or Gateway Client mode ICX30 HWC connects to a remote VPN server LAN Subnet USER FQDN LAN Subnet FQDN Gateway mode ICX30 HWC acts as a VPN server IP LAN Subnet Client
11. different subnet temporarily set the IP address of your PC to 192 168 0 xxx with a subnet of 255 255 255 0 IP address 192 168 0 Subnet mask 255 255 255 0 Open a web browser and enter the ICX30 HWC default address of http 192 168 0 250 8080 Once the ICX30 HWC homepage opens enter the USERNAME and PASSWORD to log in You will be able to customize these later The default USERNAME is admin and the default PASSWORD is password Username Password password After successful login the homepage displays data from the Status tab H B RadioLinx Status Network Interface Advanced Setup Administrator System Up Time Oday 5h 26m 15s System Time 2013 12 13 22 48 38 Board F W Version 1CX30 1 1 18 DF1 201311280051 Signal Level 77 dBm WAN Ready to Connect Cell Net Disconnect 0 LAN IP 10 1 3 186 Netmask 255 255 255 0 MAC 00 0d 8d a4 00 17 Received Packets 11340 KBytes Sent Packets 16320 KBytes Serial Received Bytes 0 Sent Bytes 0 Cellular Data Usage Page 14 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Configuration Webpage 3G Cellular M2M User Manual 2 2 Assigning an IP Address to the ICX30 HWC 1 Mouse over the Network Interface heading and choose LAN CONFIGURATION efe e la 4 Status Network Interface Advanced Setup Administrator WAN Configuration LAN Configuration 1 2 Enter the IP ADDRESS SUBNET MASK and DEFAULT GATEWA
12. functions from the ICX30 HWC After execution the bit will automatically reset to 0 ready for the next execution ICX30 CONTROL Get Status Reset Status Write SMS Read SMS Get Digital Analog Input Set Digital Output 1 Set Digital Output 2 Get GPS Page 56 of 64 Value 0 or 1 0 or 1 0 or 1 0 or 1 0 or 1 0 or 1 0 or 1 0 or 1 Description Reads status data from the ICX30 HWC This data will populate in the ICX30 S TATUS tag array Resets status counters in the ICX30 S TATUS tag array Sends SMS message from the ICX30 HWC to the target device s Maximum 160 characters Reads SMS message being sent to the ICX30 HWC from remote device Maximum 160 characters Reads Digital Analog Input values from the ICX30 HWC Sets digital output 1 Sets digital output 2 Heads GPS data from the ICX30 HWC ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Ethernet IP Support 3C Cellular M2M User Manual 6 3 2 ICX30 STATUS This array is populated when the ICX30 CONTROL Get Status tag is triggered A partial list of the data includes oignal strength MAC ID and IP Address Digital and Analog port data WAN and LAN data usage 3G network and SMS text data usage Uptime Temperature Firmware version Please see each tag in the ICX30 S TATUS array for its corresponding definition 6 3 3 1CX30 SMS This array contains the SMS text data for sending and receiving text m
13. improper operating results Failure to observe this information can result in injury or equipment damage 2015 ProSoft Technology All Rights Reserved Printed documentation is available for purchase Contact ProSoft Technology for pricing and availability Important Safety Information A This Equipment is Suitable For Use in Class l Division 2 Groups A B C D or Non Hazardous Locations Only B WARNING EXPLOSION HAZARD Substitution of Any Components May Impair Suitability for Class 1 Division 2 C WARNING EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is known to be non hazardous D Device must be powered by a Class 2 Power Source E Device is open type and is to be installed in an enclosure suitable for the environment that utilizes a tool removable door cover F The RS 232 serial connector Ethernet connector and I O terminal block are not for use in Hazardous Locations they are only for diagnostics and set up only G When Antenna is installed into ultimate enclosure it must be threaded to appropriate port to ensure mechanical securement Agency Approvals and Certifications Agency ATEX CE CSA CB Safety ETSI FCC IC PTCRB UL cUL ECO ID Do not operate the ProSoft Technology Wireless products in areas where blasting is in progress where explosive atmospheres may be present near medical equipment near life support equipment or any equipment which may be susce
14. intervention than a power cycle to correct ICX30 HWC is booting up and reading it s configuration Recoverable minor fault detected such as incomplete configuration Missing SIM card Power up sequence and tests 3 LED s Down to 83dB 2 LED s 85dB to 95dB 1LED 97dB to 113dB ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway GSM Communication AT amp T 3G Cellular M2M User Manual 4 GSM Communication AT amp T In This Chapter OO eos rc 43 9 9 T Co O v gt x oO 9 9 C lt COD IN iN 9 PT OPR O e ET ME 44 m O Q m IN iN Many GSM Networks have been upgraded to support HSUPA GSM Networks use SIM cards which are smart cards containing the account holder s details A SIM can generally be moved from one device to another allowing for account flexibility 4 1 HSUPA HSUPA High Speed Uplink Packet Access is a cellular technology which most closely resembles a broadband synchronous connection The upload and download speeds are maximized to provide a faster throughput reaching speeds up to 2 0 Mbit s for the uplink and 7 2 Mbit s for the downlink Please check with your network provider on the availability of HSUPA 4 2 HSDPA HSDPA High Speed Downlink Packet Access is a cellular technology allowing for higher data transfer speeds In HSDPA mode of operation max speeds are up to 7 2 Mbit s in the downlin
15. p55 cB Apply Changes 5201 Truxtun Ave 3rd Floor Bakersfield 93309 1 661 716 5100 Page 20 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Configuration Webpage 3G Cellular M2M User Manual 2 4 Configuration Webpage There are four main headings of the configuration webpage Status Network Interface Advanced Setup Administrator Mouse over each heading to reveal additional sub headings RadioLinx Status Network Interface Advanced Setup Administrator WAN Configuration LAN Configuration Lu ProSoft Technology Inc Page 21 of 64 June 22 2015 Configuration Webpage ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M 2 4 1 Status The Status web page displays the current settings of the cellular gateway including up time IP address and cellular data usage RadioLinx Status Network Interface Advanced Setup Administrator System Up Time Oday 18h 29m 39s System Time 2014 02 04 11 13 29 IMEI IMSI MC 1 Phone Number Board F W Version ICX30 1 1 36 201401271037 Cell Engine Version 03 001 Network Registration AT amp T Local network registered PIN Status PIN request deactivated Area Information LAI 310410 LAC d921 CellID 036d0042 Cell Engine Temp 102 2 Fahrenheit 39 Celsius GPS Position Fix OK Number of satellites 9 Coordinates 11903 63 W 3522 10 N Signal Level 103 dBm Network
16. your Cellular Provider The ICX30 HWC supports 3G GSM GPRS and CDMA where applicable networks It uses your cellular provider as an ISP Internet Service Provider to connect you to the Internet Cellular devices using GSM technology such as AT amp T require a SIM Subscriber Identity Module card to be installed in the radio Cellular devices using CDMA technology such as Verizon do not require a SIM card 2 3 1 Steps of a connection using GSM GPRS The Subscriber Identity Module SIM in the ICX30 HWC is a smartcard that securely stores the key identifying a cellular subscriber Generally you will only need to install a SIM once in the life of the cellular gateway and it may be pre installed by your ProSoft Technology Representative The SIM card slot is located on the front of the cellular gateway AT ETT T T Ur aaa o uU ec o Om ORo O RESET ANTA 1 Insert the SIM card into the ICX30 HWC and cycle power The SIM card is read by the ICX30 HWC upon boot up 2 Open the Network Interface gt WAN Configuration webpage RadioLinx Status Network Interface Adwanced Setup Administrator WAN Configuration LAN Configuration ProSoft Technology Inc Page 17 of 64 June 22 2015 ICX30 HWC Industrial Cellular Gateway Configuration Webpage 3G Cellular M2M User Manual 3 Enter the Access Point Name APN information in the APN NAME field This information is provided from your cellular provid
17. 15 ICX30 HWC Industrial Cellular Gateway Ethernet IP Support 3G Cellular M2M User Manual Converting latitude and longitude coordinates to decimal degrees The latitude and longitude values are both displayed in the following format dddmm mmmm where d degrees and m minutes To convert the number of minutes to a decimal value use the following formula Decimal value Minutes 60 Example ProSoft Technology Headquarters Bakersfield California USA Latitude 3522 086288 N Longitude 11903 627399 W Latitude decimal degrees 35 22 086288 60 35 36810 Longitude decimal degrees 119 3 627399 60 119 06046 35 3681 119 060457 mom Prosoft 180 0 180 6 3 6 ICX30 UTIL The ICX30 UTIL tag array does not need to be edited ProSoft Technology Inc Page 59 of 64 June 22 2015 ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M Page 60 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Support Service amp Warranty 3C Cellular M2M User Manual 7 Support Service amp Warranty In This Chapter M e Contacting Technical Support isis e khanaat Sm vakamaa 61 e M gt Waranty MAT OANA Oise Sons tro ser 62 7 1 Contacting Technical Support ProSoft Technology Inc is committed to providing the most efficient and effective support possible Before calling please gather the following i
18. 2 10430 MSG WRITE SMS ADI 105430 105530 ModuleDef MESSAGE MESSAGE MESSAGE MESSAGE MESSAGE MESSAGE MESSAGE MESSAGE MESSAGE MESSAGE Cancel Help ProSoft Technology Inc June 22 2015 Ethernet IP Support User Manual ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M 6 Click OK to confirm the import RSLogix will indicate that the import is in progress Importing resting routine Peescan 7 When the import is completed the new rung with the Add On Instruction will be visible as shown in the following illustration f RSLogix 5000 My Controller 1756 L63 MainProgram MainRoutine Ef File Edit View Search Logic Communications Tools Window Help algeid S eajie gt lt gt so asla re GIR Aol 99 Offline D RUN E Path AB_ETHIP 1 10 1 3 189 Backplane O vl l E OK et est 3e v odo 2 No Forces fi No Edits BAT 4 amp mo amp Controller My Controller Controller Tags Controller Fault Handler Add On Instruction 3 Power Up Handler 3 Tasks a MainTask C3 MainProgram Program Tags E 3 Unscheduled Programs Phases Motion Groups Ungrouped Axes Add On Instructions AOI ICX30 Parameters and Local Tags Logic Data Types gf User Defined Cg Strings gf Add On Defined E Predefined Cj Module Defined Trends 3 6 1 0 Configuration 6 1756 Backplane 1756 A7 fa 0 1756 L63 My Controller 6 1756 ENBT 4 ENBT Ta
19. Ethernet BJ 1756 ENBT A ENBT d ETHERNET BRIDGE ICX30 amp CIP Bus for ICX30 Industrial Cellular Gateway AOI ICX30 Add On Instruction for ICX30 Industrial Cellular Gateway AOI ICX30 AOI ICX30 ICX30 ICX30 ICX30 MSG GET GPS ICX30 MSG GET GPS ICX30 MSG GET lO ICX30 MSG GET 10 ICX30 MSG GET STATUS ICX30 MSG GET STATUS ICX30 MSG READ SMS PHONE ICX30 MSG READ SMS PHONE ICX30 MSG READ SMS TEXT ICX30 MSG READ SMS TIME ICX30 MSG RESET STATUS 1CX30 MSG READ SMS TEXT 1CX30 MSG READ SMS TIME ICX30 MSG RESET STATUS ICX30 MSG SET DIGITAL OUT 1 1CX30 MSG SET DIGITAL OUT 1 ICX30 MSG SET DIGITAL OUT 2 ICX30 MSG SET DIGITAL OUT 2 ICX30 MSG WRITE SMS 1CX30 MSG WRITE SMS MainRoutine Rung 0 of 1 8 The procedure has also imported new User Defined Data Types Controller Tags and the Add On instruction for your project J edes iem od Af Favorties A Addon X 9 Save the project When ready download the project to the processor ProSoft Technology Inc June 22 2015 Page 55 of 64 Ethernet IP Support User Manual 6 3 ICX30 HWC Controller Tags ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M Controller Tags are used to monitor and control elements of the ICX30 HWC from RSLogix 5000 You will only use the ICX30 xxx controller tag structure IL30 10 IL30 GPS ILRDLLITIL 6 3 1 ICX30 CONTROL This array contains trigger bits used to request
20. Fixes to Date Port Forwarding setup Extra entries were deleted when user edited an entry on the port forwarding screen Port Forwarding setup was not properly displaying multiple entries A factory reset disabled all the wireless modes except of the GSM Removed duplicate version information from the main screen Occasionally the system may reset itself to the factory default after repeated configuration and reboot changes The ICX30 LAN IP address was not being updated properly Enhancements e GRE Web interface for configuring a GRE Tunnel Generic Routing Encapsulation GRE is a tunneling protocol that encapsulates a wide variety of network layer protocols inside virtual point to point links over an Internet Protocol network ICX30 HWC Industrial Cellular Gateway Contents 3G Cellular M2M User Manual Contents bfelldig i iojeie Mie t rm ula 2 GontenbDiscldiffiels cd aeq tees vida gests erae deae ateist TUE dede Dime D get CEU 2 Important oale INIOMMaAllON az eos suce arae iue ntu od uae er EV da deste la up E Ue e dese OA 3 Ingyereyaezigim OU CO eret CT 4 MEE 231 62441010 Mey B clo li tT 4 1 Start Here 7 1 1 About the ICX30 HWC Industrial Cellular Gateway eese 7 1 1 1 ejerce IE 9 1 2 Fackade SOME IS isse alana iae ida Aa Naa ma a 10 1 3 System HEQUITSINICAIS WARNS EEMALE 10 1 4 Power m 21810 118 3 80 75 IS AAA MMA USAST Da 11 2 Configuration Webpage 13 2 1 Configurati
21. ND or DGND Voltage between AGND to DGND Voltage between Power pins to AGND or DGND ProSoft Technology Inc June 22 2015 Description 5 20 V on input mode 300 MA 0 5 3 5 V 1 5 18 V Description 1 6 V continuous 1 15 V within 1ms gt 1 KOhm 50 mA continuous 200 mA within 1ms 30 Ohm Open drain Description 110 Ohm 0 1 uF 0 20 mA 0 2 2V 49 KOhm 0 1 uF 0 10V Description gt 500 V gt 1 KV gt 1 KV Page 39 of 64 Hardware Installation ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M 3 2 2 Ethernet Cable Specifications The recommended Ethernet cable is category 5 or better A category 5 cable has four twisted pairs of wire that are color coded and cannot be swapped The module only uses two of the four pairs when running at 10 MBit or 100 MBit speeds The Ethernet port on the module is Auto Sensing Use either a standard Ethernet straight through cable or a crossover cable when connecting the module to an Ethernet hub a 10 100 1000 Base T Ethernet switch or directly to a PC The module will detect the cable type and use the appropriate pins to send and receive Ethernet signals Ethernet cabling is like U S telephone cables but have eight conductors Some hubs have one input that can accept either a straight through or crossover cable depending on switch position In this case ensure that the switch position and cable type agree Ethernet Cable Con
22. Phone number 5 to send SMS text alarm Input only Text of alarm to be sent to phone number s when status changes from High to Low Text of alarm to be sent to phone number s when status changes from Low to High Input or Output Output only Digital No1 OFF Digital No2 Open Drain Digital No1 OFF Digital No2 NULL There are two analog input channels for measuring voltage levels Analog Input Description Scan Rate 250 to 10000 ms Channel 1 Voltage 0 12V Channel 2 Current 0 20mA 2 2 V Status RAW Aino Raw analog input value for channel 1 A1 RAW Ain1 Raw analog input value for channel 2 A2 Page 34 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Configuration Webpage 3G Cellular M2M User Manual 2 4 4 Administrator The Administrator tab allows you to configure the password record logs update firmware etc RadioLinx Status Network Interface Advanced Setup Administrator Password NTP Ping Backup Logs General Upgrade Password Configure and edit the user name and password to access the configuration web page here Password Description Current Name Current login user name Current Password Current login password New Name New login user name New Password New login password Confirm Password Re enter the new login password NTP The Network Time Protocol NTP is used for clock synchronization between your ICX30 HWOC and an NTP server NTP Des
23. Webpage Setup 14 Connecting the Radio to a Network Device 38 Connecting to your Cellular Provider 17 Contacting Technical Support 61 Content Disclaimer 2 Creating a New RSLogix 5000 Project 47 D Digital I O 34 Dynamic DNS 28 E EDGE 44 Electrical Specification of I O Terminals 39 Ethernet Bridge Network Setup 50 Ethernet Cable Configuration 40 Ethernet Cable Specifications 40 Ethernet IP Support 47 EV DO 45 F Firmware Update 36 G General 36 GPRS 44 GRE Tunnel 32 GSM Communication AT amp T 43 ProSoft Technology Inc June 22 2015 Support Service amp Warranty User Manual H Hardware Installation 37 HSDPA 43 HSUPA 43 I O Terminal 38 ICX30 CONTROL 56 ICX30 GPS 58 ICX30 10 58 ICX30 SMS 57 ICX30 STATUS 57 ICX30 UTIL 59 ICX30 HWC Controller Tags 56 Important Notice 4 Important Safety Information 3 Importing the AOI 53 L LAN Configuration 26 LED Indicators 42 Limitation of Liability 4 Logs 36 MAC Filtering 28 Network Interface 24 NTP 35 Package Contents 10 Password 35 Ping 36 Pinouts 10 40 Port Forward 28 Power Requirements 11 S Security 46 Serial Port 29 Serial Port Basics 41 SNMP 28 Specifications 9 Start Here 7 Status 22 Steps of a connection using CDMA where applicable 20 Steps of a connection using GSM GPRS 17 Support Service 8 Wa
24. Y to be assigned to the ICX30 HWC You will not need to edit the rest of the parameters at this time LAN Configuration IP Address 10 1 3 186 Subnet Mask 255 755 255 0 Default Gateway 10 131 Pass Thru IP DHCP Disable ee IP Address MAC Address Interface Connected Device DHCP Client Range 192 168 0 1 192 168 0 10 1st DNS 168 126 63 1 2nd DNS 168 126 632 Apply Changes Clear ProSoft Technology Inc Page 15 of 64 June 22 2015 Configuration Webpage ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M 3 Click APPLY CHANGES The ICX30 HWC will automatically reboot RadioLinx Status Network Interface Advanced Setup Administrator The ICX30 has been configured with the new LAN settings Please close the Web Browser and use the new ICX30 IP address to access the device s web configuration page ICX30 will reboot in 582 seconds ProSoft Technology Inc 5201 Truxtun Ave 3rd Floor Bakersfield CA 93309 1 661 716 5100 4 Once the reboot is complete reset your PC back to its original IP address This IP address should now be on the same subnet as the ICX30 HWC 5 Close your browser and open a new session Enter the new IP address of the ICX30 HWC to access the configuration webpage Page 16 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Configuration Webpage 3G Cellular M2M User Manual 2 3 Connecting to
25. ar Technology CDMA CDMA2000 GSM UMTS WCDMA HSPA GPRS EDGE Bands CDMA2000 800 1900 MHz GSM 850 900 1800 1900 WCDMA 800 850 900 1900 2100 Max Downlink Speeds Up to 14 4 Mbps maximum Network dependent Max Uplink Speeds Up to 5 76 Mbps maximum Network dependent Activation SIM Slot GSM Flash Memory CDMA Security Open VPN IPSec GPS GPS EtherNet IP reporting Physical Enclosure Extruded aluminum with DIN clip Size 11 4x 14 x 3 2 cm W x Hx D 4 5 x 5 5 x 1 25 inches W x H x D Shock IEC 60068 2 27 15G 11ms Operational IEC 60068 2 27 30G 9 18ms Non Operational Vibration IEC 60068 2 6 10G 10 to 150 Hz Ethernet Port 1 10 100 Base T RJ45 connector Serial Port 1 DB9 female Serial tunneling amp encapsulation Antenna Ports 2 RP SMA connector 1 SMA Connector GPS I O Connector Six position screw terminal I O Port 2 Discrete Inputs Outputs Programmable 2 Analog Inputs 1 0 to 20 mA 1 0 to 12 VDC Weight 1 1 lbs 499g Environmental Operating Temperature 40 F to 158 F 40 C to 70 C Humidity Up to 100 RH with no condensation External Power 10 to 24 VDC Power over Ethernet 802 3af Compliant Peak Power Consumption lt 6W ProSoft Technology Inc Page 9 of 64 Start Here ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M 1 2 Package Contents The following components are included with the ICX30 HWC and are required for installation and configuration Important Before
26. beginning the installation please verify that all of the following items are present Qty Part Name Part Number Part Description 1 ICX30 HWC Cellular ICX30 HWC 3G 3G Cellular M2M Gateway 1 Antenna AO8228 OA 2dBi Omni RP SMA articulating 890 to 960 MHz 1710 to 2200 MHz 1 ProSoft Solutions DVD 001 Contains documentation for the ICX30 HWC DVD If any of these components are missing please contact ProSoft Technology Support for replacement parts 1 3 System Requirements The following system requirements are the recommended minimum specifications to successfully install and run Supported operating systems Microsoft Windows Vista Microsoft Windows XP Professional with Service Pack 1 or 2 Microsoft Windows 7 Professional 32 or 64 bit Microsoft Windows 2000 Professional with Service Pack 1 2 or 3 Microsoft Windows Server 2003 Pentium Il 450 MHz minimum Pentium III 733 MHz or better 128 Mbytes of RAM minimum 256 Mbytes of RAM recommended 100 Mbytes of free hard disk space or more based on application requirements 256 color VGA graphics adapter 800 x 600 minimum resolution True Color 1024 x 768 recommended DVD drive Ethernet hub with standard RJ45 Ethernet cable or Ethernet port with RJ45 crossover cable for direct connection to module In addition you will need Aconnection to an existing wired or wireless Ethernet network with a Static or Dynamic IP address for your computer
27. cription Current Time Current Year Month Day Hour Minute Second Enable Enables NTP client update with an NTP server NTP Server Address of NTP server Time Zone Local time zone of the ICX30 HWC ProSoft Technology Inc Page 35 of 64 June 22 2015 Configuration Webpage ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M Ping You can ping a remote device to determine whether you can connect to it Ping Description IP Address Host Name WAN IP address or host name to be pinged Backup The configuration of the ICX30 HWC can be saved to a file for backup The file can also be loaded back into the ICX30 HWC Restoring to factory default can be done here as well as pressing and holding the RESET button on the top of the radio Backup Save Reload Description Save Settings to File Saves configuration to a file Load Settings from File Browse for the selected configuration file and click UPLOAD Restore to Factory Default Restores to ICX30 HWC factory default Logs Record system logs of ICX30 HWC activity for analysis Logs Description Enable Logs System logs enabled for review General Adjust the settings to access the configuration web page here General Description Web Access Web access via HTTPS or HTTP and Port Number HTTP Access on WAN Allows or blocks web page access from the WAN NAT Enable or disable network address translation Firmware Update Upgrade the ICX30 HWC firmware here Upgrade Descripti
28. e GPRS is packet switched with many users sharing the same transmission channel but only transmitting when they have data to send This means that the total available bandwidth can be immediately dedicated to those users who are actually sending at any given moment providing higher utilization where users only send or receive data intermittently GPRS provides speeds of 30 70 kbps with bursts up to 170 kbps Page 44 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway CDMA Communication Verizon 3C Cellular M2M User Manual 9 9 1 9 2 CDMA Communication Verizon In This Chapter EE DO Eee 45 D cce a aT ea Gane ene eee 45 MS SSO CUM Yes aaa sait ja E iA tati aaa 46 CDMA Code Division Multiple Access where applicable is the underlying digital radio network technology used by many cellular providers across the globe and is prevalent in North America To provide backward compatibility and seamless connections in a wider range of locations your ICX30 HWC will fall back to 1x when EV DO is not available ICX30 HWC is certified with the prominent North American 1x and EV DO carriers EV DO EV DO Evolution Data Optimized provides a broadband like cellular data connection that is 10 times faster than 1x CDMA service With the high speed connection users can experience faster downloading when accessing the Internet and retrieving e mails including large attachments and other bandw
29. e number assigned to the SIM card Firmware version of the cellular hardware Version of cellular engine processor Mobile equipment identifier number unique CDMA equipment Registered local cellular network PIN request activated deactivated LAI Local Area Identity LAC Location Area Code CelllD Cellular ID Temperature of cellular engine processor Position Fix Invalid OK Number of Satellites 0 to 10 Coordinates Longitude and Latitude Signal level of cellular network dBm Type of cellular technology in use Example HSUPA for GSM Status of cellular network connection IP Address of the ICX30 HWC on the WAN Total number of sent packets on the WAN Total number of received packets on the WAN Number of days hours minutes seconds connected to the WAN Number of disconnects from the WAN IP Address of the ICX30 HWC on the LAN Subnet mask MAC address Total number of received packets on the LAN Total number of sent packets on the LAN Total number of bytes received on the serial port Total number of bytes sent from the serial port Number of bytes received and sent in the current day Number of bytes received and sent in the current month Number of bytes received and sent from the previous day Number of bytes received and sent from the previous month Page 23 of 64 ICX30 HWC Industrial Cellular Gateway Configuration Webpage 3C Cellular M2M User Manual 2 4 2 Network Interface The Network Interface tab all
30. ector The serial port uses a standard DB9 connector for RS 232 connectivity 3 2 1 VO Terminal There are two digital input output and two analog terminals on the ICX30 HWTC An SMS text message can be configured and sent to your phone upon change of the digital input s See Configuration Webpage Terminal Description D1 Digital terminal 1 can be configured as Input or Output DG Digital signal ground D2 Digital terminal 2 can be configured as Input or Output AG Analog signal ground A1 Analog input 1 voltage 0 12 V A2 Analog input 2 current 0 20 mA 2 2 V Page 38 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M Electrical Specification of l O Terminals Hardware Installation User Manual Limiting Values Outside of limiting value may damage hardware permanently even for a short duration Terminal Digital input voltage Digital output sinking current Analog input CH1 voltage Analog input CH2 voltage Digital O Digital I O Operating input voltage range Operating input voltage range Input impedance Operating output sinking current max Operating output sinking current max Output impedance Output type Analog Inputs 12 AD input Analog Input CH1 Input impedance CH1 Input current CH1 Input voltage CH2 Input impedance CH2 Input voltage Isolation Voltages Isolation Voltage Voltage among any Power pins RJ 45 Ethernet pins AG
31. ellites 4 Coordinates 11903 64 W 3522 10 N Signal Level 111 dBm Network PS attached in HSDPA HSUPA capable cell E 7 Cw WILL Ww NW KI WWW rr aU T CPP LIP M WM 7 0 ProSoft Technology Inc Page 19 of 64 June 22 2015 Configuration Webpage User Manual ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M 2 3 2 Steps of a connection using CDMA where applicable 1 When your ICX30 HWC is powered on it automatically searches for cellular service using CDMA based cellular technology 2 Your ICX30 HWC establishes a PPP Point to Point Protocol or dial up connection link to the Verizon network also called registering on the network and receives an IP address 3 When your ICX30 HWC has received its IP address from your cellular provider a connection to the Internet or the cellular network is also available for computers or other devices to connect directly to the ICX30 HWC E Moss CT T A Cellular X4 QUO cs i PP Pw KN n 77 ET Ny r A vo C Internet 4 A OQ Noti sica i RadioLinx Status WAN Configuration Mode Carrier Dialup Periodic Reset User Name Password Authentication Roaming Data Plan Limit Data Block Ping Check ProSoft Technology Inc Network Interface Advanced Setup Administrator Verizon Sprint C Custom 77 Disable y Hours GS 4243 com PAP amp CHAP s Disable M Enable Start Day fo Plan Size
32. er Click APPLY CHANGES The ICX30 HWC will reboot Ne e e Bia Status Network Interface Advanced Setup Administrator WAN Configuration Mode APN Name 4 After the ICX30 HWC reboots it establishes a PPP Point to Point Protocol or dial up connection link to your cellular provider network also called registering on the network and receives an IP address 5 When the ICX30 HWC has received its IP address from your cellular provider a connection to the Internet or the cellular network is also available for computers or other devices to connect directly to the ICX30 HWC a N V A Cellular 4 e m MESA M 0 4 KAN gt 7 x PAKS eme m m D Internet 4 Wi kan A Page 18 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Configuration Webpage 3G Cellular M2M User Manual 6 The GSM network information is now displayed on the Status web page RadioLinx Status Network Interface Advanced Setup Administrator System Up Time Oday Oh 27m 40s System Time 2014 02 03 05 11 30 IMEI IMSI ICC Phone Number Board F W Version ICX30 1 1 36 201401271037 Cell Engine Version 03 001 Network Registration AT amp T Local network registered PIN Status PIN request deactivated Area Information LAI 310410 LAC d921 CellID 036d0042 Cell Engine Temp 111 2 Fahrenheit 44 Celsius GPS Position Fix OK Number of sat
33. essages The ICX30 SMS READ array contains the SMS text message data received by the ICX30 HWC If the ICX30 HWC receives a new SMS text message the ICX30 STATUS SMS MSGs Received tag will increment by one This tag refreshes by triggering the ICX30 CONTROL Read SMS tag The data in this array is overwritten on every re trigger of the ICX30 CONTROL Read SMS tag ICX30 SMS READ Value Description DateTime ASCII String Date and time of received SMS text message Phone Number ASCII String Phone number of sender including country and area code prefixes Ex 16617165100 Text Str ASCII String Received message text Maximum 160 characters The ICX30 SMS WHRITE array contains the SMS text message data to send to multiple SMS text devices This array must be populated before sending the message by triggering the ICX30 CONTROL Write SMS tag ICX30 SMS WRITE Value Description Message Byte Count 1 to 160 Number of characters in the message Message ASCII String Text of message to be sent Maximum 160 characters Phone Count 1to5 Quantity of phone numbers to send to Ph Number X ASCII String Phone number target device including country and area code prefixes Ex 16617165100 Up to 5 phone numbers ProSoft Technology Inc Page 57 of 64 June 22 2015 Ethernet IP Support User Manual 6 3 4 1CX30 10 ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M This array contains the Analog and Digital input values of the ICX30 HWC Thi
34. et IP Support In This Chapter Creating a New RSLogix 5000 Project nnnnnennnnnenneni 47 Importing the AOL P 53 ICX30 HWC Controller Tags cccccccccceeceesseeeeeeeseeeeeeeeeeeeessaeeeeeeeeess 56 The ICX30 HWC provides connectivity via the Rockwell Ethernet IP communications protocol as a Class 3 client You can monitor and control remote I O as well as send PLC to SMS text messages for alarms Also PLC s and SCADA software can monitor the diagnostics of the cellular gateway 6 1 Creating a New RSLogix 5000 Project 1 Open the File menu and select NEW rs RSLopix 5000 Edi Mew Search Lope Communicators Toots iis New cela ca i on Select your controller TYPE Select the REVISION of your controller Revision 16 or newer only Enter a NAME for your controller such as My Controller Select your CHASSIS TYPE O RON ProSoft Technology Inc Page 47 of 64 June 22 2015 Ethernet IP Support ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M 6 Select SLOT x indicating the slot location of your controller Hew Controller Aller Bode ET Controll ogiS563 Controller UNE Redundancy Enabled A Cheeses Type 1755 44 455g Corirollogs Charit lgi p 4 aL Cresta Ir T Ailogs MiFi 7 Click OK 6 1 1 Adding a 1756 ENBT to the Project 1 You will need to add a 1756 ENBT Ethernet Bridge module to the project In the C
35. figuration Note The standard connector view shown is color coded for a straight through cable Crossover cable Straight through cable RJ 45 PIN RJ 45 PIN RJ 45 PIN RJ 45 PIN 1 Rx 3 TX 1 Rx 1 Tx 2 Rx 6 Tx 2 Rx 2 Tx 3 TX 1 Rx 3 TX 3 Rx 6 Tx 2 Rx 6 Tx 6 Rx 12345678 87654321 Page 40 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Hardware Installation 3C Cellular M2M User Manual 3 2 3 Serial Port Basics The use of hardware handshaking control and monitoring of signal lines depends on the requirements of the networked device If no hardware handshaking will be used the cable to connect to the port is as shown below RS 232 Application Port Cable No Handshaking DB 9 Male RS 232 Device wo 2 v ro eo COM s COM If hardware handshaking is required the cable to connect to the port is as shown below RS 232 Application Port Cable Hardware Handshaking DB 9 Male RS 232 Device TxD RxD wo m RTS CTS CTS RTS Signal signal Common Common DTR Ly DSR DCD ProSoft Technology Inc Page 41 of 64 June 22 2015 Hardware Installation User Manual 3 3 LED Indicators LED Power RF Transmit RF Receive Serial GPS NS MS Signal Strength Page 42 of 64 Color Green Green Green Green Green Amber Off Green Green Red Red Amber Off Green Green Red Red Amber Gree
36. idth intensive applications EV DO is often referred to as Mobile Broadband and Cellular Broadband EV DO revision A is an enhancement on the original revision 0 adding expanded upload capabilities and a more robust connection overall In addition to increasing the downlink speed revision A also increases the uplink speed In addition it is backwards compatible and automatically connects with existing and broadly deployed EV DO Rev 0 and 1x networks ensuring reliable and pervasive connectivity Note Your ICX30 HWC does not have a second antenna for received diversity Received diversity is disabled by default 1x 1x provides a digital cellular telephony system and can provide wireless Internet access at speeds between 60 and 80 kbps with bursts up to 144 kbps ProSoft Technology Inc Page 45 of 64 June 22 2015 CDMA Communication Verizon ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M 5 3 Security 1x and EV DO data transmissions are highly secure Originally developed based upon the spread spectrum pioneered by the US Department of Defense security in CDMA technologies is obtained by spreading the digital information contained in a particular signal of interest over multiple coded paths over a much greater bandwidth than the original signal Page 46 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Ethernet IP Support 3G Cellular M2M User Manual 6 Ethern
37. imeout Mode Modbus Point To Point Server Client Remote 1CX30 Server IP Address ProSoft Technology Inc June 22 2015 Description Baud rate used on the ICX30 HWC serial port Data bits Parity otop bits Flow control enable or disable Number of characters the ICX30 HWC will wait until a timeout is determined from the device connected to the serial port Disable Modbus Point To Point Modbus Point To Multipoint DF 1 see below Description Server ICX30 HWC serial port is connected to a Modbus slave Client ICX30 HWC serial port is connected to a Modbus master Client mode only IP address of remote ICX30 HWC that is connected to the Modbus slave Page 29 of 64 Configuration Webpage User Manual Modbus Point To Multipoint Server Client TCP IP Protocol Remote 1CX30 Server IP Address Listen Port No Modbus DF1 ICX30 Serial Port Master Slave Listen Port Number Remote 1CX30 Master IP Address Page 30 of 64 Port Add Address Mapping Start ID End ID Add Remote ICX30 Address Slave ID Port ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M Description Server ICX30 HWC serial port is connected to one or more Modbus slaves Client 2 ICX30 HWC serial port is connected to a Modbus master UDP Server mode only WAN IP address of Modbus master radio Modbus service port usually 502 Client mode only Defines the Modbus service port to listen to
38. indow 110 Configuration 23 1756 Backplane 1756 47 B 0 1756 L63 My_Controller z B EE 1756 ENBT A ENET 5 Save the RSLogix 5000 project ProSoft Technology Inc Page 49 of 64 June 22 2015 Ethernet IP Support ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M 6 1 2 Ethernet Bridge Network Setup 1 An Ethernet Bridge needs to be added to the 1756 ENBT module In the Controller Organization window click the right mouse button on the 1756 ENBT to open a shortcut menu On the shortcut menu choose NEW MODULE 110 Configuration 1756 Backplane 1756 47 Aa 0 1756 L63 My Controller 9 EAA i Mew Module A Cut Ckri x Copy Ctrl C Delete Del Cross Reference Ctrl E Properties Alt Enter 2 his action opens the Select Module dialog box Select the ETHERNET BRIDGE module under the Communications directory and click OK lll Select Module Module Description Vendor j Communications ETHERNET BRIDGE Generic EtherMet IP CIP Bridge Allen Bradley ETHERNET MODULE Generic Ethernet Module Allen Bradley EtherNet IP SoftLogix5800 EtherMet IF Allen Bradlev Find Add Favorite Bu Category By Vendor Favorites Page 50 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Ethernet IP Support 3G Cellular M2M User Manual 3 This action opens the New Module dialog box ICX30 must be entered as the NAME Note The IP Address ca
39. ing the AOI 1 Inthe Controller Organization window expand the Tasks folder and subfolders until you reach the MainProgram folder 2 Inthe MainProgram folder double click to open the MAINROUTINE ladder 3 Select an empty rung in the routine and click the right mouse button to open a shortcut menu On the shortcut menu choose IMPORT RUNGS fa RSLogix 5000 My Controller 1756 L63 MainProgram MainRoutine Ef File Edit View Search Logic Communications Tools Window Help eN alsa amp e gt 3002 asla vig ARa 9 No Forces F OK E A BAT H i iE e 0 ROA gt zz M UO D JA Favorites Add On A Alarms amp Bt A TimeriCounter XT Controller My Controller Controller Tags Controller Fault Handler Power Up Handler amp y Tasks MainTask C MainProgram Program Tags 4 CutRung Ctrl x gt Copy Rung Ctrl C End E MainRoutine Delete Rung Del Unscheduled Programs Phases Add Rung Ctrl R 2j 3 Motion Groups Ungrouped Axes Edit Rung Enter Add On Instructions Edit Rung Comment Ctrl D Data Types Import Rungs Cg User Defined C Strings m Add On Defined E Predefined Export Rungs ProSoft Technology Inc Page 53 of 64 June 22 2015 Ethernet IP Support User Manual ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M 4 Navigate to the location on your PC where you
40. into the DDNS server Password Key Password to log into the DDNS server SNMP oimple Network Management Protocol SNMP is a set of protocols for managing a network It is used to configure and collect information from network devices SNMP Description Activate Enable or disable SNMP manager System Name System name of SNMP network System Contact Email address of SNMP network administrator Write Community Name Private Write community string disabled default Public Write community string enabled Page 28 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M SNMP Read Community Name 1st Trap Server IP 2nd Trap Server IP 3rd Trap Server IP SNMPv3 Serial Port Configuration Webpage User Manual Description Private Read community string disabled Public Read community string enabled default IP address of the 1st trap server The ICX30 HWC will report the trap message this IP address IP address of the 2nd trap server The ICX30 HWC will report the trap message this IP address IP address of the 3rd trap server The ICX30 HWC will report the trap message this IP address Use SNMP version 3 reporting and features The RS 232 serial port supports the Modbus and DF1 industrial communication protocols For either protocol a master or slave s can be connected to the ICX30 HWC serial port Serial Port Baud Rate Data Parity Stop Flow Control Characters T
41. istered SIM Not Inserted VPN Tunnel OpenVPN 32 0 Fahrenheit 0 Position Fix Invalid GRE Tunnel linates 0 00 W 0 00 S Digital I O Analog Input Waiting to register with network 0 192 168 0 250 255 255 255 0 00 0d 8d a4 00 0f 846 KBytes 263 KBytes 0 Bytes 0 Bytes 0 Bytes 0 Bytes ProSoft Technology Inc ProSoft Technology Inc June 22 2015 Page 27 of 64 Configuration Webpage ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M Port Forward Port forwarding allows a remote computer or device to access a device on the ICX30 HWC LAN Port Forwarding Description IP Address Redirect IP address Target device IP address on the LAN WAN Port WAN port number range 1 to 65535 LAN Port LAN port number range 1 to 65535 Note There is a limit of nine 9 entries in the Port Forwarding table MAC Filtering Entries in this table are used to restrict certain types of data packets from your local network to the Internet through the ICX30 HWC These filters can be helpful in securing or restricting access to your local network MAC Filtering Description MAC Address MAC address of the device allowed to connect to the internet Dynamic DNS Dynamic DNS DDNS is a method of mapping IP addresses that are assigned to a domain name Dynamic DNS Description Service Provider Server DDNS service web page Domain Name Sets the DDNS host name or alias from DDNS server User Name Email User name to log
42. k and 384 kbit s in the uplink HSDPA uses Adaptive Modulation and Coding AMC fast packet scheduling at the Node B Base Station and fast retransmissions from Node B known as HARQ Hybrid Automatic Repeat Request to deliver the improved downlink performance vs UMTS and EDGE HSPDA and HSUPA falls back to UMTS EDGE or GPRS in order of precedence This feature allows you to have seamless connectivity no matter where your ICX30 HWC is located ProSoft Technology Inc Page 43 of 64 June 22 2015 GSM Communication AT amp T ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M 4 3 4 4 4 5 UMTS UMTS Universal Mobile Telecommunications System supports up to 1920 kbit s data transfer rates although most users can expect performance up to 384 kbit s A UMTS network uses a pair of 5 MHz channels one in the 1900 MHz range for uplink and one in the 2100 MHz range for downlink EDGE EDGE Enhanced Data rates for GSM Evolution provides end to end packet data services with an enhanced connectivity building on GPRS technology and using the established GSM networks EDGE provides higher transmission rates and better transmission quality for data than GPRS EDGE can carry data at speeds typically up to 384 kbit s in packet mode When EDGE is not available your ICX30 HWC will fall back to GPRS for the connection to your cellular provider to provide continued connectivity GPRS General Packet Radio Servic
43. mode only Local group Fully Qualified Domain Name FQDN is user defined Ex User test Client mode IP LAN Subnet Gateway mode Dynamic IP USER FQDN Dynamic IP FQDN Client mode only WAN IP address of gateway ICX30 HWC LAN IP address of gateway ICX30 HWC Only the first two octets are needed Ex XXX YYY 0 0 255 255 255 0 Gateway mode only Remote group Fully Qualified Domain Name FQDN is user defined Ex User test1 On Key to connect in either mode MODP1024 or MODP1536 DES 3DES AES192 or AES256 MD5 or SHA1 DES 3DES AES192 or AES256 MD5 or SHA1 The Virtual Private Network VPN Tunnel allows you to access a private local network through the ICX30 HWC The DHCP LAN must be enabled when using the VPN Tunnel VPN Tunnel OpenVPN Server Client Interface Type Protocol Authorization Encryption Cipher TLS Renegotiation Time LZO Compression ProSoft Technology Inc June 22 2015 Description Disable or Client Network Tunnel TUN TCP or UDP Disable Transport Layer Security TLS authorization None Use Default AES 128 CBC AES 192 CBC or AES 256 CBC Transport Layer Security renegotiation time in seconds Disabled None Enabled Adaptive Page 31 of 64 Configuration Webpage User Manual VPN Tunnel OpenVPN Port Server Address Custom Configuration Certificate Authority Client Certificate Client Key GRE Tunnel ICX30 HWC Industrial Cellular Gateway 3G Cellular
44. n State Steady Blinking Blinking Blinking Steady Steady Steady Steady Blinking Steady Blinking Steady Steady Steady Blinking Steady Blinking Steady Steady ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M Description Remains lit while powered up Data being transmitted out to the 3G network Data being received from the 3G network Data being transmitted or received on the serial port GPS link established and running GPS link not established GPS antenna is disconnected Cellular tower Network Status ICX30 HWC is powered off ICX30 HWC is waiting to register with the cellular network during power up cycle ICX30 HWC connected to the cellular tower ICX30 HWC is trying to connect to the cellular tower The signal is too weak A duplicate IP address has been discovered on the network Non recoverable major network fault One or more established connections has timed out The state remains until all time out connections have been re established or a reset occurs Recoverable minor fault has occurred Power up sequence and tests Module Status ICX30 HWC is powered off ICX30 HWC is operating correctly with all initialization complete ICX30 HWC is in process of configuring or waiting for configuration information ICX30 HWC has detected a non recoverable major fault RAM error corrupt storage non unique MAC address all errors which require more
45. n be on the LAN or WAN This is the connection to the outside world for the 1756 ENBT A gateway may be needed if a different subnet is used Hew Module Type ETHERNET BRIDGE Generic EtherMet IP CIP Bridge Parent EHET Name 04 30 Address Host Mame Descriptions IP Address 2 4 4 2 4 4 Hast Name Open Module Properties S Help 4 The ETHERNET BRIDGE now appears in the Controller Organization window under the 1756 ENBT module 110 Configuration 1756 Backplane 1756 47 BI 0 1756 L63 My Cantroller P 6 1756 EMBT 4 ENBT z Ethernet i 1756 EMBT A EMET A ETHERNET BRIDGE 14 30 E JIP Bus ProSoft Technology Inc Page 51 of 64 June 22 2015 Ethernet IP Support ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M 5 Double click the ETHERNET BRIDGE icon in the Controller Organization window to open the Module Properties window Click on the Connection tab and check the INHIBIT MODULE box Click OK M Module Properties ENBT ETHERNET BRIDGE 1 1 General Connection Module Info Port Configuration Port Diagnostics Requested Packet Interval AFI ms Major Fault On Controller IF Connection Fails While in Run Made Module Fault Status Offline L ancel Apply Help 6 Save the file Page 52 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Ethernet IP Support 3G Cellular M2M User Manual 6 2 Import
46. nformation to assist in expediting this process 1 Product Version Number 2 System architecture 3 Network details If the issue is hardware related we will also need information regarding Module configuration and associated ladder files if any Module operation and any unusual behavior Configuration Debug status information LED patterns Details about the serial Ethernet or Fieldbus devices interfaced to the module if any OI RON Note For technical support calls within the United States ProSoft s 24 7 after hours phone support is available for urgent plant down issues Detailed contact information for all our worldwide locations is available on the following page ProSoft Technology Inc Page 61 of 64 June 22 2015 Support Service amp Warranty User Manual 7 2 Internet Asia Pacific location in Malaysia Asia Pacific location in China Europe location in Toulouse France Europe location in Dubai UAE North America location in California Latin America Oficina Regional Latin America location in Puebla Mexico Brasil location in Sao Paulo ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M Web Site www prosoft technology com support E mail address support prosoft technology com Tel 603 7724 2080 E mail asiapc prosoft technology com Languages spoken include Chinese English Tel 86 21 5187 7337 x888 E mail asiapc prosoft technology com Languages sp
47. oft Technology Inc Page 11 of 64 June 22 2015 Start Here ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M Page 12 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Configuration Webpage 3C Cellular M2M User Manual 2 Configuration Webpage In This Chapter Configuration Webpage Setup erernnnnennnnnnn ann nns 14 4 Assigning an IP Address to the ICX30 HW GO eseeeseeeeee 15 Connecting to your Cellular Provider seseeeeeeee 17 Configuration Webpage rrnnnerrrnnnnnnnnnrrnnnennnne 21 The configuration webpage is used to configure and manage the ICX30 HWC First time setup must be performed over a wired network where provider specific cellular configuration details are configured Once initially setup you can access the webserver over the LAN and cellular networks unless LAN access is disabled Key benefits of the web based configurator include Login and configure device parameters Adjust network settings Change security settings Update events reporting Update firmware ProSoft Technology Inc Page 13 of 64 June 22 2015 Configuration Webpage ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M 2 1 Configuration Webpage Setup 1 The default IP address of the ICX30 HWC is 192 168 0 250 If your PC is on a
48. oken include Chinese English Tel 33 0 5 34 36 87 20 E mail support EMEA Qprosoft technology com Languages spoken include French English Tel 971 4 214 6911 E mail mea prosoft technology com Languages spoken include English Hindi Tel 1 661 716 5100 E mail support prosoft technology com Languages spoken include English Spanish Tel 1 281 2989109 E Mail latinam prosoft technology com Languages spoken include Spanish English Tel 52 222 3 99 6565 E mail soporte prosoft technology com Languages spoken include Spanish Tel 55 11 5083 3776 E mail brasil Oprosoft technology com Languages spoken include Portuguese English Warranty Information For complete details regarding ProSoft Technology s TERMS amp CONDITIONS OF SALE WARRANTY SUPPORT SERVICE AND RETURN MATERIAL AUTHORIZATION INSTRUCTIONS please see the documents on the ProSoft Solutions DVD or go to www prosoft technology legal Documentation is subject to change without notice Page 62 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M Index 1x 45 A About the ICX30 HWC Industrial Cellular Gateway 7 Adding a 1756 ENBT to the Project 48 Administrator 35 Advanced Setup 27 Analog Input 34 Antenna Installation 37 Assigning an IP Address to the ICX30 HWC 15 B Backup 36 C CDMA Communication Verizon 45 Configuration Webpage 13 21 Configuration
49. on Select File BROWSE and select the firmware file and click UPGRADE Page 36 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Hardware Installation 3C Cellular M2M User Manual 3 Hardware Installation In This Chapter Antenna Installation een nmm nemen nennen 37 Connecting the Radio to a Network Device sesseseesss 38 s IFED IndiGalOlS PANAMA A edo teca iati dobd decns vee M EEE 42 The ICX30 HWC should be mounted in a position that allows easy access for the cables so they are not bent constricted in close proximity to high amperage or exposed to extreme temperatures The LEDs on the front panel should be visible for ease of operational verification You should ensure that there is adequate airflow around the device but kept free from direct exposure to the elements such as sun rain dust and so on Caution The ICX30 HWC is in a hardened case and designed for use in industrial and extreme environments However unless you are using cables expressly designed for such environments they can fail if exposed to the same conditions the ICX30 HWC can withstand 3 1 Antenna Installation Antennas selected should not exceed a maximum gain of 5 dBi under standard installation configuration In more complex installations such as those requiring long lengths of cable and or multiple connections it is imperative that the installer follo
50. on Webpage Setup ccccccecccccccessseceeeeeeeeeceeeeseeeeeeeesseeeeeeeesaaaeseseesaaess 14 2 2 Assigning an IP Address to the ICX30 HWGC nnnnnrennnnnnannennnnnnnnea nne 15 2 3 Connecting to your Cellular Provider nnrerrnnnnennenennnneneennnnneanne nen 17 2 3 1 steps of a connection using GSM GPRS ssessessseeeeeeneeeennnns 17 2 3 2 Steps of a connection using CDMA where applicable 20 2 4 Configuration WEDDAGE ccccccsseseceeceeeseceeeceeueeceeecsauseeeeeeuaaeeeessuaaeeeeessaaeeeesseaeess 21 2 4 1 viz M aS E 22 2 4 2 NODNVOIK INTC deas Aii ia cual tt a e Neu og dau m tab ru duco Ul n cus mE D UAE 24 2 4 3 Advanced Selllusostencestsc doc chee uiui aao Do ruinae icut vu quotes fet suis itus icc SAMA 27 2 4 4 AAOPFSIBISIEBIOE 5o cocos Eruca mp eia cute Pocos ete beet b vett axi daamil SU carcere a 35 3 Hardware Installation 37 3 1 Amenna nstallat secre a uta sas pm aout ALASES 37 3 2 Connecting the Radio to a Network Device cccecccceeeseeeeeeeecaeeeeeeeseaeeeeeeesaeees 38 3 2 1 OP Terminal ssd ooi esteso eant en ER re SR rece pestem ens ise bati cus ae cs tcu ques 38 3 2 2 Ethernet Cable Specifications nrnnnvennennnnnnenne nan nnnnnna nn nnnnnn enn nn enne 40 3 2 3 Serial FOM BASIO diei reo RE itaalia ants 41 3 3 LEDANdICALO cce 42
51. ontroller Organization window select I O CONFIGURATION and click the right mouse button to open a shortcut menu On the shortcut menu choose NEW MODULE 8 1 0 Configuration J 1756 Badplane 1756 A 2 This action opens the Select Module dialog box Select the 1756 ENBT under the Communications directory and click OK Page 48 of 64 ProSoft Technology Inc June 22 2015 ICX30 HWC Industrial Cellular Gateway Ethernet IP Support 3G Cellular M2M User Manual E 5elect Module Module Description Vendor Analog Communications 1756 EMBT 1756 10 100 Mbps Ethernet Bridge Twisted Pair Media Allen Bradley 1756 EMET A 1756 Ethernet Communication Interface Allen Bradley 1756 ENET B 1756 Ethernet Communication Interface Allen Bradley 1756 EWEBJIA 1756 10 100 Mbps Ethernet Bridge w Enhanced Web Serv Allen Bradley 1756 RTO 1756 RemnFe TiO RIO ThEerFace Allen Rr adlev i m Find Add Favorite By Category Favorites 3 Enter the NAME SLOT REVISION and IP ADDRESS of the 1756 ENBT module and click OK New Module Type 1756 ENBT 1756 10 100 Mbps Ethernet Bridge Twisted Panr Media Vendor Allen Bradley Parent Local M arne EMET Address Hast Mame Description fe IP Address 1 1 1 1 Hast Mame Slot 6 E Revision 4 1 EJ Electronic Keping Compatible keping Open Module Properties Cancel Help 4 The 1756 ENBT module now appears in the Controller Organization w
52. ows you to configure the WAN Wide Area Network and LAN Local Area Network of the ICX30 HWC efe e Mia a Status Network Interface Advanced Setup Administrator WAN Configuration LAN Configuration t WAN Configuration ICX30 HWC WAN configuration RadioLinx Status Network Interface Advanced Setup Administrator WAN Configuration Mode GSM APN Name Auto PIN Disable PIN code Dialup 99 Periodic Reset Disable Hours User Name Password Authentication PAP amp CHAP Roaming Disable X Data Plan Limit Disable Start Day Plan Size 1 MB Data Block Disable Ping Check Disable Apply Changes ProSoft Technology Inc 1111111111 Page 24 of 64 June 22 2015 ICX30 HWC Industrial Cellular Gateway 3G Cellular M2M WAN Configuration Mode APN Name Auto PIN PIN Code Carrier CDMA only Dialup Periodic Reset User Name Password Authentication Roaming Data Plan Limit Start Day Plan Size Data Block Ping Check Interval Fail Count 1st Server and Server ProSoft Technology Inc June 22 2015 Configuration Webpage User Manual Description GSM or CDMA Access point name provided by the carrier Enable or Disable Optional PIN code to unlock SIM card Verizon Sprint Custom Seguence to dial to establish a connection This field cannot be left blank when you APPLY CHANGES It will re populate with a carrier assigned value upon reboot
53. ptible to any form of radio interference In such areas the ProSoft Technology Wireless products MUST BE POWERED OFF The ProSoft Technology Wireless products can transmit signals that could interfere with this equipment Do not operate the ProSoft Technology Wireless products in any aircraft whether the aircraft is on the ground or in flight In aircraft the ProSoft Technology Wireless products MUST BE POWERED OFF When operating the ProSoft Technology Wireless products can transmit signals that could interfere with various onboard systems Note Some airlines may permit the use of cellular phones while the aircraft is on the ground and the door is open The ICX30 HWC may be used at this time The driver or operator of any vehicle should not operate the ProSoft Technology Wireless products while in control of a vehicle Doing so will detract from the driver or operator s control and operation of that vehicle In some states and provinces operating such communications devices while in control of a vehicle is an offense Important Notice Due to the nature of wireless communications data transmission and reception can never be guaranteed Data may be delayed corrupted that is it may have errors or be totally lost Significant delays or losses of data are rare when wireless devices such as ProSoft Technology Wireless products are used in a normal manner with a well constructed network Nevertheless the ICX30 HWC should not be used in situation
54. rranty 61 System Requirements 10 U UMTS 44 Page 63 of 64 Support Service amp Warranty ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M V VPN Tunnel IPSEC 31 VPN Tunnel Open VPN 31 W WAN Configuration 24 Warranty Information 62 Y Your Feedback Please 2 Page 64 of 64 ProSoft Technology Inc June 22 2015
55. s array is updated by triggering the ICX30 CONTROL Get Digital Analog Input tag Caution The data in this array is overwritten on every re trigger of the IGX30 CONTROL Get Digital Analog Input tag ICX30 IO Analog 1 Analog 2 Digital 1 Digital 2 6 3 5 ICX30 GPS Value 0 to 32767 0 to 32767 0 or 1 0 or 1 Description Analog input 1 raw value Analog input 2 raw value Digital input 1 raw value when output 1 no current O current flow Digital input 2 raw value when output 1 no current O current flow This array contains the current ICX30 HWC GPS data This array is updated by triggering the ICX30 CONTROL Get GPS tag Caution The data in this array is overwritten on every re trigger of the ICX30 CONTROL Get GPS tag ICX30 GPS UTC Time Latitude Longitude Horiz Dilution Altitude GEOID Height Last Update Interval Fix Quality Satellite Num Page 58 of 64 Value Heal Heal Heal Real Real SINT SINT SINT SINT Description UTC Time in HHMMSS x format H hour M minute S second Latitude in dddmm mmmm format d degrees m minutes Longitude in dddmm mmmm format d degrees m minutes Horizontal Dilution of precision Altitude in meters above sea level Geoid Height in meters Time since last update GPS signal guality 0 Invalid 1 Ideal 1 to 2 Excellent 2 to 4 Good 4 to 8 Moderate Number of Satellites in range ProSoft Technology Inc June 22 20
56. s the duty of any such user or integrator to perform the appropriate and complete risk analysis evaluation and testing of the products with respect to the relevant specific application or use thereof Neither ProSoft Technology nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein Information in this document including illustrations specifications and dimensions may contain technical inaccuracies or typographical errors ProSoft Technology makes no warranty or representation as to its accuracy and assumes no liability for and reserves the right to correct such inaccuracies or errors at any time without notice If you have any suggestions for improvements or amendments or have found errors in this publication please notify us No part of this document may be reproduced in any form or by any means electronic or mechanical including photocopying without express written permission of ProSoft Technology All pertinent state regional and local safety regulations must be observed when installing and using this product For reasons of safety and to help ensure compliance with documented system data only the manufacturer should perform repairs to components When devices are used for applications with technical safety requirements the relevant instructions must be followed Failure to use ProSoft Technology software or approved software with our hardware products may result in injury harm or
57. s where failure to transmit or receive data could result in damage of any kind to the user or any other party including but not limited to personal injury death or loss of property ProSoft Technology accepts no responsibility for damages of any kind resulting from delays or errors in data transmitted or received using ProSoft Technology products or for failure of the ICX30 HWC to transmit or receive such data Limitation of Liability The information in this manual is subject to change without notice and does not represent a commitment on the part of ProSoft Technology PROSOFT TECHNOLOCY INC AND ITS AFFILIATES SPECIFICALLY DISCLAIM LIABILITY FOR ANY AND ALL DIRECT INDIRECT SPECIAL GENERAL INCIDENTAL CONSEQUENTIAL PUNITIVE OR EXEMPLARY DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS OR REVENUE OR ANTICIPATED PROFITS OR REVENUE ARISING OUT OF THE USE OR INABILITY TO USE ANY PROSOFT TECHNOLOGY PRODUCT EVEN IF PROSOFT TECHNOLOGY AND OR ITS AFFILIATES HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR THEY ARE FORESEEABLE OR FOR CLAIMS BY ANY THIRD PARTY Notwithstanding the foregoing in no event shall ProSoft Technology and or its affiliates aggregate liability arising under or in connection with the ProSoft Technology product regardless of the number of events occurrences or claims giving rise to liability be in excess of the price paid by the purchaser for the ProSoft Technology product Release Date 1 1 50 5 28 15
58. saved the Add On Instruction for example Desktop Select the L5X file and click IMPORT Import Rungs Look in Ei Desktop ty Documents X My Computer Sony Network Places eircx30 Addon Rung v1 1 L5 My Recent Documents Desktop My Documents hy Computer hy Hetwork Places File name 0430 Add n A ung vl 1 L5s w Files of tupe Files containing Into Ovenwrite Selected Rungs Cancel Help 5 This action opens the mport Configuration dialog box showing the controller tags that will be created IM Import Configuration EL rind Oe BAR Find Repace Find Within Final Name Import Content MainT ask CS MainProgram lg E MainRoutine Rungs References Add On Instructions Data Types 5 Errors W amings Page 54 of 64 Configure Tag References import Name Operation ta FinalName SP Alias For_ Data Type ADI 1230 12430 ICX30_MSG_G ICX30_MSG_G ICX30_MSG_G ICX30_MSG_R ICX30 MSG R ICX30 MSG R 12830 MSG R IC 30 MSG S IC 30 MSG 5 1230 MSG Use Existing Use Existing Use Existing Use Existing Use Existing Use Existing Use Existing Use Existing Use Existing Use Existing Use Existing Use Existing AOLICK30 12530 10430 MSG GET GPS 12430 MSG GET 10 12430 MSG GET STATUS 12430 MSG READ SMS PHONE 10430 MSG READ SMS TEXT 1430 MSG READ SMS TIME 10430 MSG RESET STATUS ICX30 MSG SET DIGITAL OUT 1 10430 MSG SET DIGITAL OUT
59. w maximum dBi gain guidelines in accordance with the radio communications regulations of the Federal Communications Commission FCC Industry Canada or your country s regulatory body if used outside the US Your ICX30 HWC will work with most quad band GSM cellular antennas with a SMA connector Connect the primary antenna or primary RF cable directly to the ANT A antenna connector on the front of the ICX30 HWC A secondary antenna port labeled ANT B is provided to attach an additional antenna Use of a secondary antenna is not required but will often increase cellular reliability and throughput performance This device is not intended for use within close proximity of the human body Antenna installation should have at least 20 cm separation from the operator Tip When using a cable to an antenna placed away from the modem minimize the length of your cable All gain from a more advantageous antenna placement can be lost with a long cable to the modem ProSoft Technology Inc Page 37 of 64 June 22 2015 Hardware Installation ICX30 HWC Industrial Cellular Gateway User Manual 3G Cellular M2M 3 2 Connecting the Radio to a Network Device Di DG D2 AG AT A2 ETHERNET lo EE d Ou 10 24 VOC IN vo GW MAX J The application ports are located on the bottom of the radio The I O port uses 2 Discrete Inputs Outputs and 1 Analog Input The Ethernet port uses a standard RJ45 conn