1. Manufacturer Albert Einstein StraBe 7 92637 Weiden Das bezeichnete Produkt stimmt mit Die Ubereinstimmung des bezeichneten der folgenden Europ ischen Richtlinie Produktes mit den Vorschriften der Richtli berein nie wird nachgewiesen durch die vollst n We herewith confirm that the above men dige Einhaltung folgender Normen tioned product meets the requirements of The correspondence of the above mentioned the following standard product with these requirements is proved by the fact that these products meet with the fol lowing single standards Nummer Bezeichnung Europaische Norm 2004 108 EG Elektromagnetische EN61000 6 2 2006 Vertr glichkeit EMV EN61000 6 4 2007 Weiden den 13 03 2013 4 7 f pa e Harald Kilian Leiter operatives Gesch ft COO Prokurist Authorized Signatory Page 23 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 6 5 Warranty Liability For the product liability is assumed for defects which existed at the de livery date according to our General Terms and Conditions Technically changes as well as errors are excepted A claim for delivery of a new product does not exist The buyer has to check the received product immediately and indicate evident defec
2. 10 bytes of output data are used in operating mode 3 The individual data bytes are assigned to the following functions Byte Designation Length Function Description No in Bytes 2s a S display data coded Page 14 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface Device control data are transmitted as bytes 2 and 3 of the output data from the DP master to the display and are used to control display brightness and blinking of individual digits as well as triggering of the self test Bit coding for these 2 bytes is shown in the following table Device Control Data Assignments o Strb brightness control 00s 100 brightness B 01g 80 brightness 103 50 brightness 11g 20 brightness east _ Os OFF 1p ON 3 7 nofunction Strb Ce Op OFF 15 ON Og OFF 1p ON Og OFF 1p ON Op OFF 13 ON Og OFF 1p ON 6 7 nofunction Global Control Data Operating Mode 3 Global control data are transmitted as bytes 0 and 1 of the output data from the DP master to the display although they are not evaluated by the display These two bytes are reserved and must be set to zero by the user Page 15 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0
3. which are se lected with Profibus configuration identifiers 0x21 0x21 Brightness and blinking are controlled by the Profibus DP master with these 4 bytes the software self test is initialized and a numeric value is transmitted as a signed integer The panel mount display calculates the appropriate decimal value from the transmitted data which lies within a range of 32768 and 32767 The calculated value is then displayed 3 4 Operating Mode 3 Ten bytes of output data are used in operating mode 3 which are se lected with Profibus configuration identifiers 0x21 0x21 0x25 Bright ness and blinking are controlled by the Profibus DP master with these 10 bytes the software self test is initialized and a numeric value is transmitted as a signed integer and a display value is transmitted for each of the six digits 3 5 Brightness Control Brightness is controlled via device control data and is only available in operating modes 2 and 3 Four different brightness levels are available including 100 80 50 and 20 3 6 Blinker Function The blinker function is controlled via device control data and is only available in operating modes 2 and 3 The characters displayed at each of the six digits can be caused to blink independent of one another The blinking frequency is approximately 1 Hz 3 7 Hardware Self Test The hardware self test can be activated with the DIP switches All of the segments at all six digits are switched on an
4. Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface Display Data Operating Mode 3 Digit 6 5 4 3 2 1 Output Data Byte No 4 5 6 7 8 9 List of Displayable Characters Code in Binary Code Displayed HEX Bit No Character SSS Ei el al el al el Ss ooo of x x x of of of of o oxo of x x x of of of if i oxo2 of x x x of of tf of 2 xos of x x x of of if if 3 O I oxo4 of x x x of if of of 4 oxo5 of x x x of if of if 5 e oxo of x x x of ifl al of 6 xoz of x x x of if af if 7 oos of x x x tf of of of amp oxo of x x x 1f of of if 9 ooa of x x x il of if of oo of x x x 1f of if if O E oc of x x x tf if of of HH ewm TSS St SSS oo of x x xt if if tf of pP So SSS x ifl il afl if SS aa x is not evaluated x x x gt lt 1x x x gt x lt 1x gt x lt gt lt x x x x x x x gt lt 1x x gt lt gt lt 1x x gt lt gt lt x x gt lt X X X lt gt lt gt lt X x 1x 1x x gt lt x P lt x x x x x A decimal point is entered after the corresponding character by setting bit number 7 However this function is only available in operating mode 3 Page 16 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst
5. de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 4 Connector Pin Assignments Power Profibus DP DIP Switch PE I emio LED Monitor Flat Connector PE Earth connection 3 Pin Connector Terminal n c Page 17 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface LED Monitor Bottom of Housing Colour Function LED Start Up Off RUN Green Normal Operation blinks at approx 2 Hz Error lit continuously off Start Up On INTERNAL Normal Operation On Error blinks at approx 1 Hz off Start Up Off BUS Yellow Normal Operation Profibus DP active On Profibus DP inactive Off DIP Switch MANMAAAR 2 3 4 8 DIP Switches DIP1 Profibus DP Address Operating Mode Profibus DP Address ON DE Do2 b 0o Eoo BE o e 0 oe pwoz a o ors BR No 8 HR REN Operating Mode ON OFF DIP 1 Normal Operation Self Test Normal Self Test Operation Bus Termination Bottom of Housing The bus termination of the Profibus DP interface is activated by switch ing on both DIP switches position ON Page 18 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961
6. 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 4 1 Display Elements Component Function Description 6 Digit 7 Segment Displa 1 13 mm red or green illuminated 4 levels 20 50 80 100 7 segment Page 19 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 5 Housing Dimensions 5 1 Panel Cutout 93 0 0 8 Page 20 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 6 Appendix 6 1 Standard Equipment Display with current software and hardware versions Mounting materials Mating plug for power supply User s manual Floppy disc with GSD file for original purchaser 6 2 Maintenance and Care Observe the following instructions in order to assure best possible per formance of the display unit e The display must be switched off before cleaning Only solvent free cleaners may be used as the surface of the housing may otherwise be damaged Under no circumstances may moisture be allowed to enter the interior of t
7. 5 Config_Data Operating Mode 3 10 bytes of DP output data and 0 bytes input data are used for operating mode 3 hg Data I Output Function Description dentifier Data ae output data global control data reserved 1 ox21 2 output data device control data 2 ox25 6 output data display data as display value 3 16 User Parameter Data User_Prm_Data The user parameter data are not used by the display However a test is run to make sure that no user parameter data have been configured by the Profibus master If parameter data have been configured Profibus initialization is disabled and the slave s parameters must be reconfig ured Page 11 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 3 17 Output_Data Operating Mode 1 2 bytes of output data are used in operating mode 1 The individual data bytes are assigned to the following functions Byte Designation Length in Function Description Bytes No display data as signed integer The numeric value to be displayed is transmitted as a signed integer via 2 bytes of output data Display Value Coding Output_Data Displa Page 12 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst d
8. Baud 93 75 KBaud 187 5 KBaud 500 KBaud 1 5 MBaud 3 MBaud 6 MBaud 12 MBaud Protocol Profibus DP DIN 19245 Part 3 Device Database File MIPNO4D0 GSD Configuration of the display is performed with 1 2 or 3 bytes of configu ration data The display s operating mode is also selected by means of configuration data The interface receives and examines the transmitted configuration data which must conform to one of the possibilities shown in the tables below If incorrect configuration data are transmitted to the interface as regards number of bytes or identifier Profibus initialization is disabled and the slave s parameters must be reconfigured Page 10 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 3 13 Config _Data Operating Mode 1 2 bytes of DP output data and 0 bytes input data are used for operating mode 1 Byte Data Iden Output Function Description No _ tifier Data o ox21 2 output data display data as signed integer 3 14 Config_Data Operating Mode 2 4 bytes of DP output data and 0 bytes input data are used for operating mode 2 on Data I Output Function Description dentifier Data za output data device control data 1 0x21 2 output data display data as signed integer 3 1
9. bus DP Interface The Profibus DP interface is monitored by the panel mount LED display if the watchdog for the slave has been activated by the Profibus DP master If no Profibus DP connection can be established or if the con nection to the master is interrupted the following sequence appears at the display FHRHRH The status of the Profibus DP interface is also indicated at the LED monitor 3 10 LED Test The LED test function can be activated at pin 2 of the 3 pole terminal connector As soon as 24 VDC are applied to this terminal all display segments are illuminated at full brightness HHHHHH 3 11 Hardware Malfunction Display If a hardware error is detected during start up six static hyphens appear at the display As a rule this indicates that the blinker function is inactive for the RUN LED HARA Page 9 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 3 12 Profibus DP Characteristic Data ID Number 0x04D0 Maximum Output Data 2 bytes DP output data operating mode 1 4 bytes DP output data operating mode 2 10 bytes DP output data operating mode 3 Default Configuration 0x21 0x21 0x25 Parameter Data 7 bytes default User PRM none Diagnosis 6 bytes default External Diagnosis none Baud Rate 9 6 KBaud 19 2 K
10. d then back off again dur ing the hardware self test The display blinks at a rate of approx 2 Hz at full brightness OHBHHH HEHHRH Page 7 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 3 8 Software Self Test and Start Up Performance The following displays appear during the software self test and device start up row HL vee BREE vet EOHHHH cw GEHHRH vem GRRE EL cm BARBAE The software self test is performed automatically each time operating power is switched on or can be run continuously in operating modes 2 and 3 in which case it is initialized via device control data by setting the corresponding bits at the Profibus DP master fe Displaying the address During the software self test immediately after start up the display is il luminated at full brightness 100 The brightness level selected with the control data is taken into consideration during the software self test which is initialized by the Profibus DP master Page 8 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 3 9 Monitoring the Profi
11. djusted by means of control data and or in dividual characters can be caused to blink independent of one another The device is equipped with the following important functional features Profibus DP configuration with three different operating modes Brightness can be set to 4 different levels Blinker function for each of the 6 display digits at approx 1 Hz Conversion of integer values with preceding plus or minus sign Individual display digits can be driven directly Self test function via control bit from Profibus DP data or with DIP switches Self test function with DIP switches LED test with 24 VDC external e Error message indicates interruption of communications via the Profibus DP Page 4 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 2 System Overview The display is connected to a Profibus DP master via the Profibus DP Page 5 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 3 Technical Data General Specifications Display type 7 segment LED Character height 13 mm Digits 6 digits Display colour red green Opera
12. e info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 3 18 Output_Data Operating Mode 2 4 bytes of output data are used in operating mode 2 The individual data bytes are assigned to the following functions a Designation Length Function Description EDER Sie device control data 2 3 Daa 2 display data as signed integer Device control data are transmitted as bytes 0 and 1 of the output data from the DP master to the display and are used to control display brightness and blinking of individual digits as well as triggering of the self test Device Control Data Assignments No Strb brightness control 00g 100 brightness K 01g 80 brightness 10g 50 brightness 11g 20 brightness 2 fare setttest 0 OFF In ON _ Inofuncton gt 3 7 no function Strb oat reins Op OFF 15 ON 1 digit 2 blinks 0g OFF 1s ON 2 digit3blinks 0s OFF 1s ON 3 digit4blinks 03 OFF 1s ON 4 digitSblinks 03 OFF 13 ON 5 digit 6 blinks 0g OFF 13 ON Page 13 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface Display Value Coding Output _ Data Displa HEX HEX oo oO O FE ee i Tal 3 19 Output_Data Operating Mode 3
13. he device during cleaning e Protect the panel mount LED display from excessive humidity ex treme vibration direct sunlight and extreme temperatures Non observance may lead to malfunctioning or destruction of the device Under certain circumstances electrical shock fire and explosion may occur as well Information concerning allowable ambient condi tions including recommended temperature and atmospheric humid ity ranges can be found in the chapter entitled Technical Data e The display may not be placed into service if the device and or the power cable are known to be damaged e Do not attempt to open or repair the device yourself The guarantee is rendered null and void if the device is tampered with by unauthor ized persons e Observe all of the instructions and requirements which are included in this user s manual Page 21 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 6 3 Troubleshooting General Problems Problem Cause Solution LED RUN does not blink No power or incor Use only the specified supply ater Startup start up rect supply voltage voltage ti Defective device Return device for repair LED INTERNAL blinks Error during RAM Switch supply power off and test or internal then back on If the problem erro
14. microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface User s Manual microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de mipan DP Numeric Panel Mount LED Display with Profibus DP Interface Table of Contents 1 GENERAL 1 1 Special Features 2 SYSTEM OVERVIEW 3 TECHNICAL DATA 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 10 3 11 3 12 3 13 3 14 3 15 3 16 3 17 3 18 3 19 Operating Modes Operating Mode 1 Operating Mode 2 Operating Mode 3 Brightness Control Blinker Function Hardware Self Test Software Self Test and Start Up Performance Monitoring the Profibus DP Interface LED Test Hardware Malfunction Display Profibus DP Characteristic Data Config_Data Operating Mode 1 Config Data Operating Mode 2 Config Data Operating Mode 3 User Parameter Data User_Prm_Data Output_Data Operating Mode 1 Output_Data Operating Mode 2 Output_Data Operating Mode 3 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST 10 11 11 11 11 12 13 14 Page 2 mi pan DP Numeric Panel Mount LED Display with Profibus DP Interface 4 CONNECTOR PIN ASSIGNMENTS 4 1 Display Elements 5 HOUSING DIMENSIONS 5 1 Panel C
15. r persists return device for re Troubleshooting Display Problems Problem Cause Solution Only hyphens appear at Internal error Switch supply power off and the display then back on If the problem persists return device for All display segments Hardware test is Set DIP switches to normal blink activated operation Select a different brightness setting setting via the Profibus DP display via the Profibus DP Interface does not Configuration and or Correct configuration and or respond parameters are in parameters correct Troubleshooting Profibus DP Problems Problem Cause Solution Interface does not Pin assignments at Correct the pin assignments respond Profibus connector at the Profibus are connector incorrect data strands are re No bus termination Correct the bus termination or bus termination is incorrect Page 22 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 6 4 Declaration of Conformity EG Konformitatserklarung Declaration of EC Conformity Produktbezeichnung mipan DP Product name Produktbeschreibung Numerische LED Einbauanzeige mit Profibus DP Interface Product description Numeric Panel Mount LED Display with Profibus DP Interface Hersteller microSYST Systemelectronic GmbH
16. ted Kreuzer Output_Data Operating Mode 3 changed Kreuzer Power consumption differences between red green Kreuzer Housing depth changed to 60 mm Declaration of conformity warranty liability changed Logo Certified per DIN EN ISO 9001 Page 25 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de
17. ting voltage 24 VDC 20 Power consumption Red displays approx 75 mA at 24 VDC operating voltage Green displays approx 100 mA at 24 VDC operating voltage Addresses 0 to 126 Interface Profibus DP Display 0 to 9 and H E L P Blank Baud rate 9 6 KBaud to 12 MBaud Housing DIN panel mount housing metal with special surface finish Housing dimensions see chapter 5 Mounting screw clamps Protection front panel IP 65 Weight approx 270 grams Operating temperature 0 to 50 C Storage temperature 25 to 70 C 3 1 Operating Modes Three different operating modes with various functions are available for the display The operating mode is selected with the configuration data 3 2 Operating Mode 1 Two bytes of output data are used in operating mode 1 which are se lected with Profibus configuration identifier 0x21 These 2 bytes can be used to transmit a numeric value as a signed integer from the Profibus DP master The panel mount display calculates the appropriate decimal value from the transmitted data which lies within a range of 32768 and 32767 The calculated value is then displayed Page 6 microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 3 3 Operating Mode 2 Four bytes of output data are used in operating mode 2
18. ts at the latest 24 hours after detection Non observance of notification requirements is equated with acceptance of the defect Not immediately visible defects have to be indicated immediately after their perception too Generally defects and their symptoms must be described as accurately as possible in order to allow for reproducibility and elimination The buyer must provide for access to the relevant device and all required and or useful information at no charge and must make all of the required data and machine time available free of charge The guarantee does not cover defects which result from non observance of the prescribed conditions of use or from improper han dling If the device has been placed at the disposal of the buyer for test pur poses and has been purchased subsequent to such testing both parties agree that the product is to be considered used and that it has been purchased as is No guarantee claims may be made in such cases The General Terms and Conditions of microSYST Systemelectronic GmbH in current version apply as well Page 24 microSYST Systemelectronic GmbH Albert Einstein StraBe 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de mipan DP microSYST Numeric Panel Mount LED Display with Profibus DP Interface 6 6 Versions Overview Comments Description 26 11 04 24 02 05 28 02 05 21 05 08 18 03 13 22 10 13 Kreuzer Document crea
19. utout 6 APPENDIX 6 1 Standard Equipment 6 2 Maintenance and Care 6 3 Troubleshooting General Problems 6 4 Declaration of Conformity 6 5 Warranty Liability 6 6 Versions Overview microSYST Systemelectronic GmbH Albert Einstein Stra e 7 92637 Weiden Tel 49 961 39166 0 Fax 49 961 39166 10 www microsyst de info microsyst de microSYST 17 19 20 20 21 21 21 22 23 24 25 Page 3 microSYST mipan DP Numeric Panel Mount LED Display with Profibus DP Interface 1 General There s no doubt that Profibus is becoming more and more significant with the ever growing number of devices which are equipped with a Profibus interface The numeric panel mount LED display with Profibus interface is a high performance product which has been especially designed for industrial use The metal housing and rugged design of the numeric panel mount LED display with Profibus interface make it ideal for all type of applications even under adverse ambient conditions 1 1 Special Features The display has been designed for use as a data converter between a Profibus DP master and a 6 digit 7 segment display It functions as a slave module at the Profibus DP and allows for the display of data Various functions are made available depending upon configuration 2 bytes output data for operating mode 1 4 bytes output data for operat ing mode 2 10 bytes output data for operating mode 3 For example display brightness can be a