1. WT 1672A2 DOUBLE CIRCUITS POWER OUTAGE ALARM USER MANUAL WITURA TECHNOLOGY SDN BHD WT 1672A2 Power Outage Alarm User Manual V1 0 fa Overviews Power Outage Alarm is a simple to detect loss of power power cuts Once power loss is detected the unit will call and SMS texts messages to your cell phone via the mobile phone network The unit can call and SMS text messages to 5 designated phone number and or sound an audible alert to make you aware of the power failure The WT 1672A2 can detect two power circuit respectively in two different area of electrical powers either one being interruption the WT 1672A2 will activate the alarm and sending information to the administrative number allow users to know the situation in time The unit also has 1 x 30A heavy duty output can used to switch on any application like lamps pumps heater motor etc when power resume Output relay can be switched ON by calling its cell phone number or by sending an SMS command there is no call charges incurred when dialling the unit as it will recognize an authorised telephone number calling it and reject the call without answering One call to the SIM Card number will switch the device ON permanently another call with switch OFF permanently The unit supply with 1 timer input This function is important as the reminder to the owner to monitor the SIM Card expiry date User can set the SIM Card expiry date into the system and when the date overdue the uni
2. Relay off time 2013 10 10 16 33 Relay on time Relay off time Relay on time Relay off time Message switch lt ON gt Message switch lt OFF gt Scheduler Off If your SIM Card expiry 90 days you can just enter 90 days automatic trigger relay and sent you SMS text messages Check Scheduler Time Delete Scheduler ON time Delete Scheduler OFF time SMS ON The Factory Default system will acknowledge with SMS text message for every command you set SMS OFF If you decide not to allow the system text you for any acknowledgement SMS 21 0 to Switch OFF Factory Default not required for any setting The according to this command factory already set you can change to next command anytime WT 1672A2 Power Outage Alarm User Manual V1 0 If you decide not to allow the system to text you for any acknowledgement after you call to You can switch OFF the text message the unit Some Customer request this function because texts reply involved call cost Factory Default is only allow the which in the admin the phone number already program list can relay ON OFF control No setting required If user change to this commands this means that anybody can call to the unit to control the relay ON OFF Instead of using call user can sent SMS to control Relay ON Some country SMS call cost is better than call cost Instead of using call User can sent SMS to c
3. and allows you to delete the admin number in the list This command allows you to check the relay status in ON or OFF Mode WITURA TECHNOLOGY SDN BHD ene 0 1234 0 1234 new password For example if you need to change to the new PW of 1212 0 1234 1212 1 1 telephone number For example set Admin number 18617185300 into admin 2 1 2 18617185300 3 N N Admin number 1 5 For example if you want to delete admin no 2 just enter 3 2 Congratulation Within a certain time you get administrator privileges Change Password success New password lt 1212 gt Administrator 1 15989427391 2 3 4 5 Administrator 1 2 18617185300 3 4 5 Administrator i The reply will be either Relays is lt ON gt Relays is lt OFF gt When you enter 0 1234 the You you enter into programming mode the command in 10 minutes If must perform next you did not do anything the system will exist from programming mode Maximum 4 digits of passwords Set Admin Numbers 1 1 set Ist admin number 1 2 set 2nd admin number 1 3 set 3rd admin number 1 4 set 4th admin number 1 5 set 5th admin number Delete Admin Number Delete Ist admin 3 1 Delete 2nd admin 3 2 Delete 3rd admin 3 3 Delete 4th admin 3 4 Delete 5th admin 3 5 WT 1672A2 Power Outage Alarm User Manual V1 0 You must confirm the signal strength at site be
4. ber will now Latch the Relay permanently ON and Switch the device being Controlled On The Status of the Relay will remain as on until the unit receives a second Call to the Unit of which will now Latch the Relay Permanently off Both Calls used to Latch the Relay either on or off are automatically disconnected once the relays are activated and never incur any Network Call Costs Beside calls to switch off or on the unit also can be permanently switch off and on by sending the unit a text message command WITURA TECHNOLOGY SDN BHD WT 1672A2 Power Outage Alarm User Manual V1 0 Bo Step 1 The simplest set up methods to set up Administrator number Applied the KISS Principle keep it simple stupid The GSM Remote Control Switch is easy to setup and use Insert the SIM card simply use your mobile phone call to the unit your mobile phone number will automatically register as the 1st Administrators You will receive the following SMS message from the unit Administrator 1 18617185300 your phone number 2 3 4 5 Call to the SIM Card No Of WT 16727A2 Return Text Messages Administrator 1 15617135799 2 sesd H T 231 pen Messages WT 1672 Contact Teat Manunge You already finish the set up Now you can use your mobile phone call to the SIM Card number switch the device on permanently Another call to the SIM Card will switch the device off permanently If you do not required to go t
5. fore you install the unit If the signal too weak the unit will not function properly Arm The Units By default the units is Arm when disarmed the units users won t receive any notification when the alarm is activated Disarm the units By default the units is Arm when disarmed the units users won t receive any notification when the alarm is activated 10 Check the status of Alarm Checking whether the alarm is being arm or disarmed No 8 and 9 is to set schedule to trigger relay You need to set No 8 Your current time Then set No 9 the time to trigger the relay Relay only can trigger if know your time now After you finish the above step and you decide to set trigger the relay ON This command used when your relay status is OFF if you need to trigger relay OFF please use the No 10 setting i 10 1 Alarm Switch lt ON gt 10 0 Alarm Switch lt OFF gt _ 12 year month date time D Time change OK ay For example 12 201310104 Means Year 2013 October 10th 16 05 Thursday 13 1 year month date time 10 16 33 For example 13 1 201310101633 Means Year 2013 October 10th 16 33 times Relay on time 2013 10 Check Signal Strength CSQ 5 12 Signal too weak system not function CSQ 13 24 Signal Good System function well CSQ 25 32 Excellent Signal System working well Set the date time date week This func
6. hrough details setting please process to STEP3 Final Installation and Wiring WITURA TECHNOLOGY SDN BHD WT 1672A2 Power Outage Alarm User Manual V1 0 a Factory Reset If you required to change the administrator number in the future simply press the button FACTORY at the mother board until you hear the du This means the unit back to the factory default Press until you hear the du sound This means you already reset the unit to factory default Now you can start to call again to set the administrator This method of setting is only allowed to set 1 administrator number If you wish to set more administrators please go to Step 3 Installation and set up WITURA TECHNOLOGY SDN BHD WT 1672A2 Power Outage Alarm User Manual V1 0 Bo Step 2 Advance Set Up First Step of programming you must enter the factory passwords of 1234 and go the programming mode inside You only can perform the next commands after enter into programming mode If you decide to protect your privacy you can change the factory password to your new password Enter the factory password follow by your new password This command is to add telephone number into the admin list Only the number in the list can receive alarm texts message and active the relay output You can add up to 5 telephone number into the admin list This commands allow you to check what is the phone number you program in the list This comm
7. ight indicating power is present the blue network LED indicator will initially flash quickly once logged onto the network it will flash more slowly approximately one every 3 4 seconds It is recommended that the GSM Remote Control Switch be programmed to operate as required before final installation Connection Details If you are unsure how to connect the device you wish to control refer to a qualified person Connection Details Note 1 The Relay J3 Was using for turning on and off the electrical appliance only 2 User can set up the Relay by own requirement 3 If using to monitoring the Power outage only Doesn t required to connect Wire with Relay WITURA TECHNOLOGY SDN BHD WT 1672A2 Power Outage Alarm User Manual V1 0 ho Example Of Wiring Diagram Battery SIM Card Holder Power Supply 2 Power Supply 1 Power Supply 1 Power Supply 2 User Electric Appliances Production Specifications 110 240 Vdc Maximum 500mA typically 55mA maximum switching capacity 20 amps 230v ac per relay Physical Size 130 x 100 x 50mm Weight 900Grams o O Indicators Relay Telco Power C E FCC ETSI WITURA TECHNOLOGY SDN BHD WT 1672A2 Power Outage Alarm User Manual V1 0 fi Troubleshooting Ensure that your DC power supply is connected Red power LED not alight correctly positive to terminal 220v and negative to terminal N Verify 12 volts is present using a volt meter Ensure
8. ment upon the return of such equipment to any Witura branch This warranty applies ONLY to defects in components and workman ship and NOT to damage due to causes beyond the control of Witura such as incorrect voltage lightning damage mechanical shock water damage fire damage or damage arising out of abuse and improper application of the equipment Note Wherever possible return only the PCB to Witura Service Centres DO NOT return the enclosure The WT 1672A2 is a product of Witura Technology Sdn Bhd And is manufactured by Shenzhen Witura Telecommunications Co Ltd WARNING For safety reasons only connect equipment with a telecommunications compliance label This includes customer equipment previously labelled permitted or certified WITURA TECHNOLOGY SDN BHD WT 1672A2 Power Outage Alarm User Manual V1 0 is
9. ontrol Relay OFF Turn on off the administrative call WITURA TECHNOLOGY SDN BHD 22 0 23 1 23 0 24 1 24 0 25 N Mode switch lt ON gt Mode switch lt OFF gt Relay lt ON gt Relay lt OFF gt O Call Switch lt OFF gt 1 Call Switch Start Up Alarm 2 Call Switch AC down Alarm Security Mode Defaults only the numbers in the unit to list can text to the control relay If you decide anybody can the use the following commands control unit Open Mode When this commands set anybody can call to the unit the Please take note the Privacy to control system and Security before you decide to switch to OPEN MODE SMS ON Use SMS Text Message to control relay ON SMS OFF Use SMS Text Message to control Relay OFF O turn off the call features the units won t make any administrative call to number 1 when the device power up the units will call the first administrative number 2 down the units will call the when the AC power administrative number WT 1672A2 Power Outage Alarm User Manual V1 0 Step 3 Installation Insert the SIM card to access the SIM card carrier gently push the button adjacent to it insert the SIM card and carefully close the carrier Connect the cable to terminals 110V 220V amp N ensuring positive is connected to terminal 110v 200V switch on the power supply the red power LED will l
10. t will send SMS to the user to keep SIM Card active and remind the owner for reloads The system using CE and FCC approved industry internal power supply connected on board A backup lithium battery can power up at least 8 hours and will sent a power down or power restored alerts in the event of any circuits power failure The user also can download the FREE apps from Android and IOS stores as their easy monitoring and control tools Just one touch on the apps user smart phone will sent the SMS text commands to the unit The users don t need to remember the commands code The power outage warning SMS text messages also will display at the Apps for easy monitoring Typical uses include e waking you in the event of a power cut e fridge monitoring amp freezer monitoring e fish tank monitoring amp aquarium monitoring e generator monitoring e sump pump monitoring e computer equipment monitoring e heating system monitoring e chemical storage monitoring e and other applications WITURA TECHNOLOGY SDN BHD WT 1672A2 Power Outage Alarm User Manual V1 0 eo SETTING UP AND PROGRAMMING When first booting up the system you will see Blue LED Lights on the side of the Enclosure and it should light up when the Network is applied to the unit The Blue LED is the network Indicator and this will light up when attempting to log on to the network flash inconsistently until it locates the network A Phone Call to the SIM Card Num
11. tion to set the current time into the system The system must know your current time only can set the schedule time to turn on off Scheduler ON If your relay status is OFF and you decide to turn ON relay at specified times WITURA TECHNOLOGY SDN BHD WT 1672A2 Power Outage Alarm User Manual V1 0 ann This command is trigger relay OFF This command is only perform if you decide to switch OFF the relay in specified times You can check the what date and times you set to trigger relay This command to delete the schedule which you set to trigger relay ON This commands to delete the schedule which you set to trigger relay OFF This command is factory default when you sending any command to the the automatically unit system will reply with acknowledgement to prove that your setting is success If you decide not to allow the system to text you for any acknowledgement after you sent the command to the unit You can switch OFF the text message Some Customer request this function because texts reply involved call cost Factory default is when you make call to trigger relay the system will automatically reply text that your action is success WITURA TECHNOLOGY SDN BHD 13 0 year month date time day For example 13 0 201310101633 Means Year 2013 October 10th 16 33 times 15 1 15 O 21 1 21 0 22 1 Relay off time 2013 10 10 16 33 Relay on time
12. your SIM card has been activated and that the Blue network LED flashing every one second PIN request has been disabled If the unit is in a low and not every 3 seconds signal strength area consider using an external GSM antenna or changing to another network provider Ensure your telephone number is in the Administrator am not receiving confirmation test messages list and that sending text messages to your number is when program the administrators number enabled Ensure the unit is connected to the GSM network by am not receiving any text messages when observing the blue network LED it should be flashing initially programming the unit once every 3 seconds see 2 above Ensure the SIM card has credit Most but not all PAY SIM cards will be de activated by the network if not used to make an outgoing voice call The unit has been working for several months or send an SMS text message within a specific period and has now stopped responding to calls and To prevent this simply send a txt command 0 PW text commands then 2 it will reply by text message do this once a month to keep the SIM card active WITURA TECHNOLOGY SDN BHD WT 1672A2 Power Outage Alarm User Manual V1 0 ee Warranty Witura Technology Sdn Bhd warrantees the WT 1672A2 Double Circuit Power Failure Alarm System against defective parts and workmanship Witura Technology Sdn Bhd shall at its option repair or replace the defective equip