Home
netSCOPE Data Acquisition Cards for Real-Time Ethernet
Contents
1. Strictly obey to all safety rules provided by the device s manufacturer in the documentation First disconnect the power plug of the PC or of the connecting device before you open the cabinet Make sure that the power supply is off at the PC or at the connecting device Open the PC cabinet and install or remove the netSCOPE data aquistion card only after disconnecting power netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Hardware Installation and Uninstalling 41 71 7 2 Property Damage Messages Obey to the following property damage messages when installing uninstalling or replacing the netSCOPE data aquistion card 7 2 1 Device Destruction by exceeding allowed Supply Voltage Adhere for all netSCOPE data aquistion cards described in this manual the instruction hereafter NOTICE Device Destruction Use only the permissible supply voltage to operate the netSCOPE data aquistion card Operating the netSCOPE data aquistion card with a supply voltage above of the specified range leads to device destruction 7 2 2 Device Destruction by exceeding allowed Signaling Voltage Adhere for all netSCOPE data aquistion cards described in this manual the instruction hereafter NOTICE Device Destruction All I O signal pins at the netSCOPE data aquistion card tolerate only the spe
2. 1 Close all programs 2 Enter the netSCOPE LabVIEW DVD in the local DVD ROM drive gt The start screen of the autostart menu is displayed with the following options 1 EEE NVA TA VAVG Install Windows Device Driver Open Instrument Driver Directory Open Documentation Directory EthercAT Figure 17 Options in the netSCOPE for LabVIEW Autostart Menu 3 Select Open Instrument Driver Directory in the autostart menu gt The netSCOPE for LabVIEW Instrument Driver directory appears Datei Bearbeiten Ansicht Extras Organisieren v Fi ffnen v Brennen Neuer Ordner Documentation Name Anderungsdatum Typ pm Driver fscommand LabVIEW dotNetFx40 VCRedist2008 VCRedist2010 dh netSCOPE zip pm dotNetFx40 13 11 2013 11 41 Dateiordner pm VCRedist2008 13 11 2013 11 41 Dateiordner di VCRedist2010 13 11 2013 11 41 Dateiordner J netSCOPE zip 05 11 2013 10 33 ZIP komprimierte 1 117 KB netSCOPE zip Anderungsdatum 05 11 2013 10 33 Erstelldatum 13 11 2013 11 41 Offlinestatus Online ZIP komprimierter Ordner Gr e 1 08 MB Offline verf gbar Nicht verf gbar Figure 18 netSCOPE for LabVIEW Instrument Driver Directory 4 Extract the netSCOPE zip file for the netSCOPE for LabVIEW Instrument Driver to an arbitrary location netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released
3. Indicator States Indicator state Definition The indicator is constantly on The indicator is constantly off Blinking The indicator turns on and off for approximately 10 seconds Single Flash The indicator shows one short flash followed by an off phase The interval period for the flash when triggering a GPIO event is 100 ms Table 22 Indicator States netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Device Connections 50 71 10 Device Connections 10 1 Ethernet Interface For the Ethernet interface use RJ45 plugs and twisted pair cable of category 5 CAT5 or higher which consists of 4 twisted cores and has a maximum transmission rate of 100 MBit s CAT5 10 1 1 Ethernet Pin Assignment at the RJ45 Socket 3 Note The device supports the Auto Crossover function Due to this fact RX and TX can be switched Only 100 Mbit s connections 100BASE T are supported The following figure shows the RJ45 standard pin assignment Device supports 55 gt 23 55 55 Auto Crossover Pin 1 TX KX XMM eK HS F ti HEHE FE ORE OEE unction ENOT GONG NGOY6ON 6 22222222 22222222 Pin 2 TX Qooooooo oooo00000 Pin 3 RX Pin 4 Term 1 Pin 5 Term 1 Pin 6 RX Pin7 Term2 Es l Ethernet Ethernet Pin 8 Term 2 Kanal 0 Kanal 1 Figure 28 Ethernet
4. Public Hilscher 2013 Annex 12 5 Glossary 100 Base TX Auto Crossover Auto Negotiation Baud rate Boot loader 69 71 Standard for communication on Ethernet over unshielded twisted pair lines with RJ45 connectors and a baud rate of 100 MBit s according to the IEEE 802 specification Auto Crossover is a feature of an interface An interface with Auto Crossover capability will automatically detect and correct if the data lines have been exchanged vice versa Auto Negotiation is a feature of an interface An interface with Auto Negotiation will automatically determine a set of correct communication parameters Data transmission speed of a communication channel or interface Program loading the firmware into the memory of a device in order to be executed Device Description File EtherCAT Firmware Full duplex Industrial Ethernet A file containing configuration information about a device being a part of a network that can be read out by masters for system configuration Device Description Files use various formats which depend on the communication system A communication system for industrial Ethernet designed and developed by Beckhoff Automation GmbH Software running inside a device providing the basic functionality of this device The firmware is stored remanently in the flash memory circuit of the device It can be updated by a firmware download Full duplex denominates a telecommunication system
5. hilsener COMPETENGE IN COMMUNICATION User Manual netSCOPE Data Acquisition Cards for Real Time Ethernet PCI NSCP C100 RE 50 PCI Express NSCP C100 RE 50E Low Profile PCle NSCP C100 RE 70E Compact PCI NSCP C100 RE 80 Mini PCI Express NSCP C100 RE 90E Installation Operation and Hardware Description Hilscher Gesellschaft fur Systemautomation mbH www hilscher com DOC131006UMO1EN Revision 1 English 2013 11 Released Public Table of Contents 2 71 Table of Contents 1 INTRODUCTION arcsec estat esse aetna alba a i et ttt 5 1 1 About TNE User Maal usanne SG 5 1 1 1 IST Ol RES ONS wicca 8c Greene eed ee aed E E eee eee 5 1 1 2 Notes on Hardware Software and Driver Versions r rrrvrnnnrnnnrnnevnnevnnnnnnnnnennnnene 6 1 1 3 CONVENTIONS in HIS Manu 7 1 1 4 Used TenMiINOlOGY Renee 7 1 2 Contents of the netSCOPE LabVIEW DVD esse ee Uuatenagtentc nat ala 8 1 2 1 Directory Structure of the netSCOPE LabVIEW DVD eens 8 1 2 2 DOclmEentallonza m a an ee 8 1 3 LEGA NES ee ee ed Reh 9 1 3 1 GOD VM ren ie 9 1 3 2 IMBDOLIARENOlES een energie 9 1 3 3 EX CIUSIOM OL LGN essen 10 1 3 4 KA ONY EE ae a a a 10 1 3 5 EX DOM Regula lons area kelner 11 1 3 6 REGISICFEG Trademarks maa 11 1 37 Obligation to read and understand the Manual ccccccssseceeeeeeeeeeeeeeeeeeeees 11 1 3 8 Hilscher Software License Agreement uesssssssssnnnnneeennnnnnnnnnnnnnnnnnnnnnnnnnne nennen 11 2
6. Connecting the Ethernet Assembly Interface AIFX RE to the basic Card NSCP C100 RE 90E Example 44 Figure 26 Connection Schema Capturing and analyzing the Communication between a EtherCAT Master and the EtherCAT Slave 1 45 Figure 27 Demounting the basic Card NSCP C100 RE 90E from the PCI Express Mini System Connector 47 Figure 28 Ethernet Pin Assignment at the RJ45 Socket for netSCOPE Data Acquisition Card or AIFX 50 Figure 29 2x20 Pins for NSCP C100 RE 90E 51 Figure 30 Matrix Label 66 12 4 List of Tables Table 1 List of Revisions D Table 2 Reference on Hardware netSCOPE Data Acquisition Cards 6 Table 3 Reference on Drivers 6 Table 4 Reference on Software 6 Table 5 Directory Structure of the netSCOPE LabVIEW DVD 8 Table 6 Documentations netSCOPE LabVIEW DVD 8 Table 7 netSCOPE Data Acquisition Cards 12 Table 8 Safety Symbols and Sort of Warning or Principle 16 Table 9 Signal Words 16 Table 10 netSCOPE Data Acquisition Cards with integrated Ethernet Interface 19 Table 11 netSCOPE Data Acquisition Card with AIFX Assembly Interface Ethernet 19 Table 12 Slot for the netSCOPE Data Acquisition Cards 21 Table 13 Notes on the Card Height netSCOPE Data Acquisition Card Mini PCI Express 22 netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Annex Table 14 Table 15 Table 16
7. EN 61000 4 8 2010 power frequency magnetic field test EN 61000 6 2 2005 B1 2011 for industrial environments Programm Interface Interface National Instruments NI LabVIEW 2013 Platform Windows 8 7 Vista XP Server Version August 2013 Driver netSCOPE for LabVIEW Instrument Driver V1 0 x x Windows 8 7 Vista XP Table 31 Technical Data NSCP C100 RE 70E netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Technical Data 60 71 11 1 4 NSCP C100 RE 80 Description netSCOPE data aquistion card Compact PCI for for Real Time Ethernet Master or Slave Function Data Acquisition Card for Real Time Ethernet Communication Type netX 100 processor Controller FLASH 4 MB serial Flash EPROM Size of the Dual Port Memory 64 KByte System Interface Bus Type Compact PCI according to bus spec 4 refer to section Overview page 52 DPM or DMA Direct Memory Access Width for the data access to the 32 Bit Dual Port Memory DPM Process Data Interface History depth and signal Unlimited only restricted by PC memory count Signal types Input and output process values Ethernet System Supported Real Time Ethernet EtherCAT system Ethernet Frame Types Ethernet II 100 BASE TX for EtherCAT refer to section Ethernet Interface page 50 Ethernet channels 2x RJ45 passive TAP Ethernet delay
8. Limits and methods of measurement Immunity EN 61000 4 2 2009 Electrostatic discharge test EN 61000 4 3 2006 A1 2008 A2 2010 Radiated radio frequency electromagnetic field test EN 61000 4 4 2004 A1 2010 Burst Electrical fast transients burst test EN 61000 4 5 2006 Surge test EN 61000 4 6 2009 to conducted disturbances induced by radio frequency fields EN 61000 4 8 2010 power frequency magnetic field test EN 61000 6 2 2005 B1 2011 for industrial environments Programm Interface Interface National Instruments NI LabVIEW 2013 Platform Windows 8 7 Vista XP Server Version August 2013 Driver netSCOPE for LabVIEW Instrument Driver V1 0 x x Windows 8 7 Vista XP Table 29 Technical Data NSCP C100 RE 50 netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Technical Data 56 71 11 1 2 NSCP C100 RE 50E Description netSCOPE data aquistion card PCI Express for Real Time Ethernet Function Data Acquisition Card for Real Time Ethernet Communication Type netX 500 processor Controller FLASH 4 MB serial Flash EPROM Size of the Dual Port Memory 64 KByte PCI Express One Lane Port according to bus spec 2 System Interface Bus Type Rev 2 0 and bus spec 3 refer to section Overview page 52 2 GBit s Transmission Rate Data Access DPM Width
9. Public Hilscher 2013 Software Installation 38 71 6 4 Microsoft Software Components If the Microsoft components e Microsoft NET 4 0 e Microsoft Visual C 2008 Redistributable e Microsoft Visual C 2010 Redistributable are not installed on your computer install them from the netSCOPE LabVIEW DVD Therefore 1 Close all programs 2 Enter the netSCOPE LabVIEW DVD in the local DVD ROM drive gt The start screen of the autostart menu is displayed with the following options GE rar LabyvlEyv Install Windows Device Driver Open Instrument Driver Directory Open Documentation Directory EtherCAT Figure 19 Options in the netSCOPE for LabVIEW Autostart Menu 3 Select Open Instrument Driver Directory in the autostart menu gt The LabVIEW directory appears Datei Bearbeiten Ansicht Extras Organisieren v Fi ffnen In Bibliothek aufnehmen v Brennen Neuer Ordner di Documentation Name Anderungsdatum Typ di Driver di fscommand LabVIEW dotNetFx40 VCRedist2008 i VCRedist2010 dj netSCOPE zip a dotNetFx40 13 11 2013 11 41 Dateiordner VCRedist2008 13 11 2013 11 41 Dateiordner pr VCRedist2010 13 11 2013 11 41 Dateiordner netSCOPE zip 05 11 2013 10 33 ZIP komprimierte dotNetFx40 nderungsdatum 13 11 2013 11 41 Offlinestatus Online t Dateiordner Offline verf gbar Nicht verf gbar Figure 20 LabVIEW Directory 4 Install the components to your computer netSC
10. 2013 Table of Contents 4 71 10 3 Pin ASSONMEN ANE POUL BUS Lassa ee 52 10 3 1 NEED 52 10 3 2 References PGl Specificatlions un assn ee a bid 52 10 3 3 Pin Assignment for Mini PCI Express Bus NSCP C100 RE 90E 53 CE GRIN GG EAD A iossiustetis tute tntietaciedndiccatutadacntndedndntadedudnindaingeixdetndeindetadmindatndetetatudndndedatets 54 11 1 Technical Data netSCOPE Data Acquisition Cards ccccccccsseeeeeeseeeeeeseeeeeeeens 54 11 1 1 NSECP 100 BE DD zn ee een 54 111 2 NOCP G100 RE SE ape 56 11 1 3 NSGP GIOO BEITDE 2 58 11 1 4 NSGP G 100 RE SI ae AT 60 11 1 5 NSEP G100 BEIDDE so 62 11 1 6 APR Re ae essen 64 11 2 PCI IDs netSCOPE Data Acquisition Cards on the PCI Bus rarrrvrrrnnrrvrnrnnrrennnnn 65 11 3 Supported PCI Bus Commands ssnin nenene REEN ENEAS ETRE ESENE 65 Vie ANNEN 66 12 1 Matrix Labe Neat ee as ache are 66 12 2 Disposal of Waste Electronic EQuipMment ccccccccseeeceeeceseeeseeeeseesesseeeseeeesseeens 66 12 3 LISEOTFIQUFSS ae 67 12 4 OTNES 67 12 5 GOSA aan 69 12 6 COMES eee RER PRIFERE 71 netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Introduction 5 71 1 Introduction 1 1 About the User Manual This user manual provides descriptions and installation instructions of e the installation of the software and e the inst
11. 3 V 200 Slot 3 3 V NSCP C100 RE 90E PCI Express Mini System Connector 3 3 V X1 X2 One Lane correctly into the Mini PCI Express slot the element height in the Mini PCI Express slot of the connecting device must meet to the standard specifications Note As the basic card NSCP C100 RE 90E can be inserted Table 12 Slot for the netSCOPE Data Acquisition Cards The term x1 refers to the convention of the PCI Express specifications bus spec 3 to the number of lanes in the slot X1 X2 corresponds to the Hilscher convention for interface on the top or the bottom side of the netSCOPE Data Acquisition Card netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Descriptions and Requirements 22 71 3 4 3 Card Height and Panel Cutout NSCP C100 RE 90E 3 4 3 1 Notes on the Card Height Only for netSCOPE Data Acquisition Card Mini PCI Express NSCP C100 RE 90E netSCOPE Data Dimensions L x B x D Acquisition Card NSCP C100 RE 90E 51 x 30 2 0 1 x 11 mm The element heights on top of the netSCOPE data aquistion card NSCP C100 RE 90E Mini id PCI Express do not meet the standard 2 specifications m Note The element height at the bottom side of p the netSCOPE data aquistion card NSCP C100 RE 90E is in accordance with the O amp standard specifications As the netS
12. Cards 8 Insert the netSCOPE Data Acquisition Card into the Communication Link 3 Note The RJ45 socket is only for use in LAN not for telecommunication circuits For further information refer to section Ethernet Interface on page DO gt Connect the netSCOPE data aquistion card via two Ethernet connecting cables with the Ethernet interfaces of the Master and Slave1 in parallel to the communication connection to be analyzed Plug one of the Ethernet connecting cable to the Master and one to the Slave 1 as displayed in the picture below Master Slave 1 Eth ernet Ethernet netSCOPE Card Ethernet Figure 26 Connection Schema Capturing and analyzing the Communication between a EtherCAT Master and the EtherCAT Slave 1 9 Connect the PC or the connecting device to the power supply and switch it on gt Connect the PC or the connecting device to the power supply gt Switch on the PC or the connecting device netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Hardware Installation and Uninstalling 46 71 7 4 Uninstalling netSCOPE Data Acquisition Cards 1 Take safety precautions Lethal Electrical Shock caused by parts with more than 50V gt Disconnect the power plug of the PC or of the connecting device gt Make sure that the power supply is off at the
13. English 2013 11 Released Public Hilscher 2013 Technical Data 63 71 NSCP C100 RE 90E Parameter Value Storage temperature range 0T 70 C Humidity 10 95 relative humidity no condensation permitted Device Dimensions L x W x H 51 x 30 2 0 1 x 11 mm W 30 1mm 30 3 mm The printed circuit board PCB has become wider on the right side by 0 1 mm 0 3 mm thus deviating from the norm For further details on the element heights refer to section Card Height and Panel Cutout NSCP C100 RE 90E Notes on the Card Height on page 22 Mounting Installation PCI Express Mini System Connector 3 3 V X1 X2 One Lane refer to section Slot for the netSCOPE Data Acquisition Cards page 21 es Emission EN 55011 2009 A1 2010 CISPR 11 2009 Class A Radio disturbance characteristics Limits and methods of measurement Immunity EN 61000 4 2 2009 Electrostatic discharge test EN 61000 4 3 2006 A1 2008 A2 2010 Radiated radio frequency electromagnetic field test EN 61000 4 4 2004 A1 2010 Burst Electrical fast transients burst test EN 61000 4 5 2006 Surge test EN 61000 4 6 2009 to conducted disturbances induced by radio frequency fields EN 61000 4 8 2010 power frequency magnetic field test EN 61000 6 2 2005 B1 2011 for industrial environments Programm Interface Interface National Instruments NI LabVIEW 2013 Platform Windows 8 7 Vista XP Server Version August 2013 Driver netSCOPE fo
14. INSTALLATION AND UNINSTALLING nnne 40 7 1 Safety Messages on Personal Injury c cecccecceeeeeeeeeeeeceeseeeeeeeseeeeeeeseeeeeeeseeeseneeas 40 7 1 1 Electrical Shock Hazard 11x tel osp eee 40 7 2 Property Damage Messages za nennen een 41 7 2 1 Device Destruction by exceeding allowed Supply Voltage 0044444 41 7 2 2 Device Destruction by exceeding allowed Signaling Voltage 41 7 2 3 Electrostatically sensitive D VICES cccscccccsseeeeceeseeeceeeseeessaseecsesseesseseeenes 41 7 3 Installing netSCOPE Data Acquisition Card eerrnnnrrvnnnnnrvvnnnnnrrnnrnnerernrnnerernnnerrennnnn 42 7 4 Uninstalling netSCOPE Data Acquisition Cards rrronnrrrvrnnnnnorrrnnnrorrrnnnnennrnnsnennnnn 46 8 TROUBLE SHOOTING sara een 48 8 1 Instructions for Problem Solving cccccccsseeececeeeecesceeeeeeeeseeecessaeeeeeeseaueeeeseaeeeesaaaes 48 9 KEEP DES RAR A Sa 49 10 DEVIGE BONNECTIONS Se eek 50 10 1 EINETHEL INICHACE een ee ge ee 50 10 1 1 Ethernet Pin Assignment at the RJ45 Socket rrrrrnrrnnnnnnrrnnrnnnnrnennrnnnnrnennrnnnsnee 50 10 1 2 Eihernel Gonneeli nData enges 50 10 2 Gable ANE 51 10 2 1 Pin Assignment for Cable Connector Ethernet rrrrrrrrrnnnnnnnnrvrrrnnnnnnnnvrnnnnrnnnnn 51 netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher
15. PC and make sure that you are discharged when you install uninstall the netSCOPE card Front Plate Sticker Only NSCP C100 RE 50 NSCP C100 RE SOE NSCP C100 RE 70E and NSCP C100 RE 80 2 Fix Front Plate Sticker Note Your netSCOPE data aquistion card contains a front plate sticker depending by your card type STAO STA1 SYS NSCP C100 RE 50 or NSCP NSCP C100 RE 70E NSCP C100 RE 80 C100 RE 50E Figure 23 Front Plate Stickers for different netSCOPE Data Acquisition Card Types The label on the sticker indicates the following LED names LED Neme Color J Meaning Table 18 LED Labeling For further information refer to chapter LED Descriptions page 49 netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Hardware Installation and Uninstalling 43 71 gt Glue the sticker on the front plate of the netSCOPE data aquistion card For the netSCOPE data aquistion card NSCP C100 RE 70E consists from two parts 1 Glue the partial sticker above with the LED names STA1 STAO and SYS above the LEDs on the front plate 2 Glue the partial sticker below with the names LINK and RX TX below of the RJ45 on the front plate Table 19 Fix Front Plate Sticker at the NSCP C100 RE 70E Installing the netSCOPE data aquistion card 3 Take safety precautions Lethal Ele
16. PC or at the connecting device NOTICE Electrostatically sensitive Devices gt To prevent damage to the PC and the netSCOPE card make sure that the netSCOPE card is grounded via the endplate and the PC and make sure that you are discharged when you install uninstall the netSCOPE card 2 Remove the Ethernet connecting cables gt Remove the Ethernet connecting cables between the netSCOPE data aquistion card and the Master or the Device 3 Open cabinet gt Open the cabinet of the PC or of the connecting device 4 Uninstall netSCOPE data aquistion card PCI PCI Express or Low Profile PCI Express gt Loosen the netSCOPE data aquistion card gt Remove the netSCOPE data aquistion card from the PCI slot or from the PCI express slot Compact PCI Unscrew the netSCOPE data aquistion card First press the grey button at the ejection lever gt gt gt Then press the ejection lever downwards gt Remove the netSCOPE data aquistion card from the compact PCI slot gt Possibly reinsert a blank plate Mini PCI Express 5 Uninstall the Ethernet AIFX RE assembly interface Only NSCP C100 RE 90E gt Remove the AIFX RE assembly interface from the PC housing panel gt Disconnect the cable from the basic card NSCP C100 RE 90E cable connector Ethernet X4 netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 Englis
17. RJ45 passive TAP Ethernet delay lt 1 us Auto Negotiation Auto Crossover Connector additional external TAP with zero delay possible Time stamp resolution 10 ns Display LED Display System Status LED STAO LED Status 0 duo LED STA1 LED Status 1 duo LED LED Ethernet Link Status yellow LED Ethernet RX TX Status green Refer to chapter LED Descriptions page 49 Power supply Supply Voltage 3 3 V dc 5 refer to section Power Supply and Host netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 wn lt wn re OD Technical Data 59 71 NSCP C100 RE 70E Parameter Value interiace page 23 typically Environmental 0 C 65 C 10 95 relative humidity no condensation permitted PCI Express x4 slot 3 3 V refer to section Slot for the netSCOPE Data Acquisition Cards page 21 Yes Emission EN 55011 2009 A1 2010 CISPR 11 2009 Class A Radio disturbance characteristics Limits and methods of measurement Immunity EN 61000 4 2 2009 Electrostatic discharge test EN 61000 4 3 2006 A1 2008 A2 2010 Radiated radio frequency electromagnetic field test EN 61000 4 4 2004 A1 2010 Burst Electrical fast transients burst test EN 61000 4 5 2006 Surge test EN 61000 4 6 2009 to conducted disturbances induced by radio frequency fields
18. between two communication partners which allows simultaneous communication in both directions is called a full duplex telecommunication system At such a system it will be possible to transmit data even if currently data are received Full duplex is the opposite of Half_duplex telecommunication system At such a system receiving data inhibits the transmission of data Half duplex is the opposite of Full duplex See Real Time Ethernet netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Annex LabVIEW netSCOPE netX PCB PCle RE Real Time Ethernet RJ45 70 71 Laboratory Virtual Instrumentation Engineering Workbench Hilscher s netSCOPE is a tool to capture network traffic from Real Time Ethernet systems and to display data content for analysis purposes networX on chip next generation of communication controllers Printed Circuit Board printed machine made circuit board Abbreviation for PCI Express RE stands for Real Time Ethernet Real Time Ethernet Industrial Ethernet is an extension of the Ethernet networking technology for industrial purposes with very good real time features and performance There is a variety of different Real Time Ethernet systems on the market e g EtherCAT which are incompatible with each other A connector type often used for Ethernet
19. connecting device e Open the PC cabinet and install or remove the netSCOPE data aquistion card only after disconnecting power An electrical shock is the result of a current flowing through the human body The resulting effect depends on the intensity and duration of the current and on its path through the body Currents in the range of approximately 1 2 mA can cause effects in persons with good health and indirectly cause injuries resulting from startle responses Higher currents can cause more direct effects such as burns muscle spasms or ventricular fibrillation In dry conditions permanent voltages up to approximately 42 4 V peak or 60 V are not considered as dangerous if the contact area is equivalent to the size of a human hand Reference Safety S2 netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Safety 14 71 2 5 Safety Instructions to avoid Property Damage To avoid property damage respectively device destruction to the netSCOPE data aquistion card and to your system you necessarily must read understand and follow the following safety instructions and safety messages in this manual about danger causing property damage before you install and operate your netSCOPE data aquistion card 2 5 1 Device Destruction by exceeding allowed Supply Voltage To avoid device destruction d
20. connection It has been standardized by the Federal Communications Commission of the USA FCC netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Annex 12 6 Contacts Headquarters Germany Hilscher Gesellschaft fur Systemautomation mbH Rheinstrasse 15 65795 Hattersheim Phone 49 0 6190 9907 0 Fax 49 0 6190 9907 50 E Mail info hilscher com Support Phone 49 0 6190 9907 99 E Mail de support hilscher com Subsidiaries China Hilscher Systemautomation Shanghai Co Ltd 200010 Shanghai Phone 86 0 21 6355 5161 E Mail info hilscher cn Support Phone 86 0 21 6355 5161 E Mail cn supportQhilscher com France Hilscher France S a r l 69500 Bron Phone 33 0 4 72 37 98 40 E Mail info hilscher fr Support Phone 33 0 4 72 37 98 40 E Mail fr support hilscher com India Hilscher India Pvt Ltd New Delhi 110 065 Phone 91 11 26915430 E Mail info hilscher in Italy Hilscher Italia S r l 20090 Vimodrone MI Phone 39 02 25007068 E Mail info hilscher it Support Phone 39 02 25007068 E Mail it supportQhilscher com 71 71 Japan Hilscher Japan KK Tokyo 160 0022 Phone 81 0 3 5362 0521 E Mail info hilscher jp Support Phone 81 0 3 5362 0521 E Mail jp support hilscher com Korea Hilscher Korea Inc Seongnam
21. gt Press down the basic card until it snaps into place T o o me pag 2 pap a Te gle Pi en Pt TB EE mr LE bm SK be an eee Cee PET VE u en GE its a A a m rE Plug the basic card into the PCI Express Mini and press down the card until it System Connector on the mainboard snaps into place Figure 24 Mounting the basic Card NSCP C100 RE 90E into the PCI Express Mini System Connector Connecting AIFX Assembly Interface Only for NSCP C100 RE 90E 6 Connect the Ethernet assembly interface AIFX RE to the basic card gt Connect the cable connector Ethernet X1 on the AIFX RE with the cable gt Connect the cable connector Ethernet X4 on the basic card NSCP C100 RE 90E with the cable Example NSCP C100 RE 90E with Cable Connector Ethernet X4 Bn a T 2 60062 PEN ge N SE ay 5 g E 8 ro ha 7 Fr 3 thee S Figure 25 Connecting the Ethernet Assembly Interface AIFX RE to the basic Card NSCP C100 RE 90E Example netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Hardware Installation and Uninstalling 45 71 After this 7 Close cabinet gt Close the cabinet of the PC or connecting device Insert the netSCOPE Data Acquisition Card into the Communication Link all netSCOPE Data Acquisition
22. lt 1 us additional external TAP with zero delay possible yellow E netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Technical Data 61 71 NSCP C100 RE 80 Parameter Value Power supply Supply Voltage 3 3 V dc 5 refer to section Power Supply and Host Interface page 23 Maximum Current at 3 3 V 650 mA typically Connector Via Compact PCI Bus Environmental Operating temperature range 0 C 70 C Conditions Air flow during measurement 0 5m s Storage temperature range 0 70 C Humidity 10 95 relative humidity no condensation permitted Device Dimensions L x W x H 162 2 x 100 x 20 mm Mounting Installation Compact PCI slot 3 3 V refer to section Slot for the netSCOPE Data Acquisition Cards page 21 Windows 8 7 Vista XP Table 32 Technical Data NSCP C100 RE 80 CE Sign CE Sign Yes Emission EN 55011 2009 A1 2010 CISPR 11 2009 Class A Radio disturbance characteristics Limits and methods of measurement Immunity EN 61000 4 2 2009 Electrostatic discharge test EN 61000 4 3 2006 A1 2008 A2 2010 Radiated radio frequency electromagnetic field test EN 61000 4 4 2004 A1 2010 Burst Electrical fast transients burst test EN 61000 4 5 2006 Surge test EN 61000 4 6 2009 to conducted disturbances induced by radio frequ
23. observe the following instructions These instructions apply to all netSCOPE data aquistion cards described in this manual e All I O signal pins at the netSCOPE data aquistion card tolerate only the specified signaling voltage e Operating of your netSCOPE data aquistion card with a signaling voltage other than the specified signaling voltage may lead to severe damage to the netSCOPE data aquistion card netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Safety 15 71 The data on the mandatory signaling voltage for the netSCOPE data aquistion cards described in this manual you find in the section Power Supply and Host Interface on page 23 There the required and permitted signaling voltage is provided by device type 2 5 3 Electrostatically sensitive Devices This equipment is sensitive to electrostatic discharge which cause internal damage and affect normal operation Therefore adhere to the necessary safety precautions for components that are vulnerable with electrostatic discharge if you install or replace your device Follow the guidelines listed hereafter when you handle this equipment e Touch a grounded object to discharge potential static e Wear an approved grounding wriststrap e Do not touch connectors or pins on the netSCOPE data aquistion card e Do not touch circuit components
24. or other data of the delivered product No warranty or guarantee regarding the correctness or accuracy of the information is assumed We reserve the right to change our products and their specification as well as related user manuals accompanying texts and documentation at all times and without advance notice without obligation to report the change Changes will be included in future manuals and do not constitute any obligations There is no entitlement to revisions of delivered documents The manual delivered with the product applies Hilscher Gesellschaft fur Systemautomation mbH is not liable under any circumstances for direct indirect incidental or follow on damage or loss of earnings resulting from the use of the information contained in this publication netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Introduction 10 71 1 3 3 Exclusion of Liability The software was produced and tested with utmost care by Hilscher Gesellschaft fur Systemautomation mbH and is made available as is No warranty can be assumed for the performance and flawlessness of the software for all usage conditions and cases and for the results produced when utilized by the user Liability for any damages that may result from the use of the hardware or software or related documents is limited to cases of intent or grossl
25. the Diagnosis of a netSCOPE Data Acquisition Card netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Device Drawings 28 71 5 Device Drawings 5 1 netSCOPE Data Acquisition Cards PCI NSCP C100 RE 50 and PCI Express NSCP C100 RE 50E System LED gelb gr n yellow green Status LED 0 und 1 rot gr n Status LED 0 and 1 red green Ethernet RJ45 Buchse Ethernet RJ45 Socket Channel 0 CH 0 m p 41 edi dell oom g ec g S Kanal 1 Channel 1 CH 1 PCI Bus X2 X1 124 polig 124 pin Figure 2 NSCP C100 RE 50 System LED gelb gr n yellow green Status LED 0 und 1 rot gr n Status LED 0 and 1 red green Ethernet RJ45 Buchse Ethernet RJ45 Socket Kanal 0 Channel 0 CH 0 g ec gg sg sg Sy Channel 1 CH 1 PCI Express Bus 36 polig 36 pin Figure 3 NSCP C100 RE 50E Note Device supports Auto Crossover Function Only 100 Mbit s connections 100BASE T are supported netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Device Drawings 29 71 The figure below shows the front plate of the netSCOPE data aquistion cards NSCP C100 RE 50 and NSCP C100 RE 50E not
26. the PC and is not used for external diagnosis The Pins 36 and 38 are disabled and are not used When you start the PC the operating system does not ask for an USB driver The pin assignment of the Pins 42 44 46 deviates from the standard specification Mini PCI Express For the netSCOPE data aquistion card NSCP C100 RE 90E pin 42 is used for Bootstart and depending by the protocol the SYNC connection is realized via the pins 44 and 46 of the mini PCI Express bus For the reference for bus spec 6 for the bus specification for Mini PCI Express refer to section References PCI Specifications on page 52 netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Technical Data 54 71 11 Technical Data 11 1 Technical Data netSCOPE Data Acquisition Cards 11 1 1 NSCP C100 RE 50 Part Name NSCP C100 RE 50 Part No 7330 100 Description netSCOPE data aquistion card PCI for Real Time Ethernet Function Data Acquisition Card for Real Time Ethernet Communication Type netX 500 processor Controller Size of the Dual Port Memory Bus Type PCI according to bus spec 1 refer to section Overview page 52 Transmission Rate 33 MHz Width for the data access to the 32 Bit Dual Port Memory DPM Process Data Interface History depth and signal Unlimited only restricted by PC memory co
27. used System LED yellow green 2 Communication Status LED 0 red green Communication Status LED 1 red green Designation and meaning depends by protocol Refer also to chapter LED Descriptions page 49 Ethernet Interface Channel 0 Ethernet Interface Channel 1 Refer also to section Ethernet Interface page 50 Figure 4 Front Plate for NSCP C100 RE 50 NSCP C100 RE 50E netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Device Drawings 30 71 52 netSCOPE Data Acquisition Cards Low Profile PCI Express NSCP C100 RE 70E Status LED 1 und 0 rot gr n Status LED 1 and 0 red green System LED gelb gr n System LED yellow green Ethernet RJ45 Buchse Ethernet RJ45 Socket p g c ol S c Kanal 1 Channel 1 CH PCI Express Bus PCI Express Bus X2 X1 64 polig 64 pin Figure 5 NSCP C100 RE 70E Hardware revision 1 Note Device supports Auto Crossover Function Only 100 Mbit s connections 100BASE T are supported The figure below shows the front plate of the netSCOPE data aquistion card NSCP C100 RE 70E not used Communication Status LEDs COM1 Communication Status LEDs COMO System LED yellow green red green Designation and meaning depends by protocol Refer also to chapter LED Descript
28. 13 11 Released Public Hilscher 2013 Getting Started 27 71 Description For detailed information see manual section Installing netSCOPE Data Bone Important Operating the Acquisition Card only for NSCP C100 netSCOPE Data Acquisition Cards RE 90E with AIFX assembly interface requires proper connection of the AIFX RE assembly interface to the basic card If so connect the Ethernet AIFX RE assembly interface to the basic card NSCP C100 RE 90E Close cabinet Close the cabinet of the PC or connecting device Insert the netSCOPE Note for all netSCOPE Data Acquisition Ethernet Interface Data Acquisition Card Cards Real Time Ethernet use in LAN not for telecommuni into the EE Note The RJ45 socket is only for cation circuits Connect the netSCOPE data aquistion card Installing netSCOPE Data via two Ethernet connecting cables with the Acquisition Card Ethernet interfaces of the Master and Slave1 in parallel to the communication connection to be analyzed 3 7 Connect the PC to the Connect the PC or the connecting device to power switch on the power supply and switch it on Data Processing with netSCOPE LabVIEW 4 1 Programming steps Perform required programming steps in Operating Instruction LabVIEW Manual netSCOPE 5 1 Date Processing Perform data recording processing and representation in LabVIEW Table 17 Steps for the Software and Hardware Installation the Configuration and for
29. 5 refer to section Power Supply and Host Interface page 23 Maximum Current at 3 3 V 800 mA typically Connector Via PCI Express Bus Environmental Operating temperature range OG 55 0 Conditions Air flow during measurement 0 5m s Storage temperature range o C 70 C Humidity 10 95 relative humidity no condensation permitted Device Dimensions L x W x H Mounting Installation PCI Express x1 slot 3 3 V refer to section Slot for the netSCOPE Data Acquisition Cards page 21 Windows 8 7 Vista XP Table 30 Technical Data NSCP C100 RE 50E CE Sign CE Sign Yes Emission EN 55011 2009 A1 2010 CISPR 11 2009 Class A Radio disturbance characteristics Limits and methods of measurement Immunity EN 61000 4 2 2009 Electrostatic discharge test EN 61000 4 3 2006 A1 2008 A2 2010 Radiated radio frequency electromagnetic field test EN 61000 4 4 2004 A1 2010 Burst Electrical fast transients burst test EN 61000 4 5 2006 Surge test EN 61000 4 6 2009 to conducted disturbances induced by radio frequency fields EN 61000 4 8 2010 power frequency magnetic field test EN 61000 6 2 2005 B1 2011 for industrial environments Programm Interface Interface National Instruments NI LabVIEW 2013 Platform Windows 8 7 Vista XP Server Version August 2013 netSCOPE for LabVIEW Instrument Driver V1 0 x x netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Descr
30. COPE data aquistion card NSCP C100 RE 90E can be 2 inserted correctly into the Mini PCI Express z slot the element height in the Mini PCI Express netX 100 Cooling Element 6 4 0 2 slot of the connecting device must meet to the Element height topside 1 83 0 18 nede een ar Note The element heights of the cable Height of the printed circuit 1 0 0 1 connectors Ethernet X4 including the cable Element height bottom side 1 3 0 1 are app 8 5 mm over PCB each Max total height D of the 11mm netSCOPE data aquistion card in milli meter Table 13 Notes on the Card Height netSCOPE Data Acquisition Card Mini PCI Express 3 4 3 2 Panel Cutout for Installing AIFX Only for netSCOPE Data Acquisition Card Mini PCI Express NSCP C100 RE 90E In order to connect the AIFX assembly interface to a netSCOPE data aquistion card Mini PCI Express with cable connector Ethernet make sure that the housing panel of the PC or of the connecting device has an appropriate cutout and holes for fastening the AIFX The panel cutout must be dimensioned sufficiently large for the interface display or control elements placed on the AIFX Partial standard cutouts can be used netSCOPE Data AIFX Panel Cutout and Holes Acquisition Card NSCP C100 AIFX RE Panel Cutout at the housing panel of the PC AEROS Required Cutout for two RJ45 Sockets Important The panel cutout layout must also cover the LEDs COM 0 and COM 1 at th
31. Device Connections 52 71 10 3 Pin Assignment at the PCI Bus 10 3 1 Overview For the netSCOPE data aquistion cards PCI PCI Express and Low Profile PCI Express the table below gives an overview about the pin assignment at the PCI bus netSCOPE Data Hardwar PCI Bus PCI Pin Assignment at the PCI Bus PCI Acquisition Card Revision Type ie Hae ve compare section page Specification standard 6 yes NSCP C100 PCI bus spec 2 RE 50E Express Rev 2 0 bus spec 3 NSCP C100 1 RE 70E NSCP C100 RE 80 3 Compact 110 yes bus spec 4 PCI NSCP C100 Mini PCI 52 no Pin Assignment for Mini PCI Express bus spec 2 RE 90E Express Bus 53 Rev 1 0a bus spec 6 Table 26 Pin Assignment at the PCI Bus 10 3 2 References PCI Specifications bus spec 1 PCI Local Bus Specification 23 February 21 2003 pcisig com bus spec 2 PCI Express Base Specification 20 e January 15 2007 bus spec 3 PCI Express Card Electromechanical Fi April 11 2007 Specification bus spec 4 CompactPCI Specification Short Form Specification ie October 26 2007 April 21 2012 bus spec 6 PCI Express Mini Card Electromechanical Fe e l March 28 2005 pcisig com Table 27 References PCI Specifications netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Device Connec
32. Gyeonggi 463 400 Phone 82 0 31 789 3715 E Mail info hilscher kr Switzerland Hilscher Swiss GmbH 4500 Solothurn Phone 41 0 32 623 6633 E Mail info hilscher ch Support Phone 49 0 6190 9907 99 E Mail ch supportQhilscher com USA Hilscher North America Inc Lisle IL 60532 Phone 1 630 505 5301 E Mail info hilscher us Support Phone 1 630 505 5301 E Mail us support hilscher com netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013
33. Mbit s gt connections 100BASE T are supported PP The meaning of the LEDs STAO and STA1 at the reverse side of the AIFX RE and the meaning of the green and yellow LEDs at RJ45Ch0 and RJ45Ch1 corresponds to the description in chapter LED Descriptions beginning from page 49 Figure 11 Front Side Ethernet Assembly Interface AIFX RE SLC OO a C 7 M2 5 1 or so S S in KE ee Leiterkarte PCB z 10 0 Oj OU X2 00 i Kanal 1 STAO Status LED 0 rot gr n Channel 1 Status LED 0 red green CH 1 STA1 Status LED 1 rot gr n SU Status LED 1 red green CU flexibles Folienkabel S flexible flat cable Kanal 0 Channel 0 CH 0 OG OU L06ecllll rn Figure 12 Dimensioning and LED Display Ethernet Assembly Interface AIFX RE netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Software Installation 34 71 6 Software Installation 6 1 netSCOPE LabVIEW DVD Autostart Menu For the software installation for your netSCOPE data aquistion card the netSCOPE LabVIEW DVD provides the netANALYZER netSCOPE Windows Device Driver the netSCOPE Software and the documentations In the netSCOPE LabVIEW DVD autostart menu you can select e Install Window
34. OPE Data Acauisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Software Installation 39 71 6 5 Documentation To open the Documentation directory 1 Enter the netSCOPE LabVIEW DVD in the local DVD ROM drive gt The start screen of the autostart menu is displayed with the following options art me ee oe VAL AAV Install Windows Device Driver Open Instrument Driver Directory Open Documentation Directory Etherc AT ilseher Figure 21 Options in the netSCOPE for LabVIEW Autostart Menu 2 Select Documentation in the autostart menu gt The Documentation directory appears e gt M Computer gt Documentation v Datei Bearbeiten Ansicht Extras Organisieren In Bibliothek aufnehmen v Brennen Neuer Ordner von DennisN Name nderungsdatum Typ di von Dietmar Bi Von Es Documentation in Adobe Acrobat Reader format PDF on ETIC Em Adobe Reader Installation_DE exe 05 11 2013 10 25 Anwendung 52 347 KB Em Adobe Reader Installation EN exe 05 11 2013 10 25 Anwendung 51 443 KB pm von Heinz J von Holger _ netSCOPE DVD Vorabstand di Documentation pm Driver 3 Elemente Offlinestatus Online Offline verf gbar Nicht verf gbar Figure 22 netSCOPE for LabVIEW Documentation Directory netSCOPE Data Acquisition Cards for Real Time Ethernet Installa
35. PETN seele 12 2 1 General Nole se 12 2 2 Intended se aussanwasessi a ia eu 12 2 3 Personne ORI MN Avv42r er 12 2 4 Safety Instructions to avoid Personal INJULY ccccccseeceeeseeeceeceeeeeeseeeeseeseeeeenseas 13 2 4 1 Electrical Shock Hazard ara na 13 2 5 Safety Instructions to avoid Property Damage uus22222000020nnnennnennnnn nennen nennen 14 2 5 1 Device Destruction by exceeding allowed Supply Voltage 04u nn 14 252 Device Destruction by exceeding allowed Signaling Voltage 14 2 5 3 Electrostatically sensitive D VICES ccccecccccssseeeceesseecseeeeeesseseeecseseeeeseaseeenes 15 2 6 Labeling of Safety Messages 16 2 7 Refererices S PN Laser 16 3 DESGRIPHONS AND REQUIREMENT Leve 17 3 1 Introduction 16 NETS COPE unse een 17 3 2 NEISGCOPE DAR Acauisiion GAS 18 3 3 Recording and analyzing Data Traffic rrrrrnrrrnrnnrrrrnnrerrnnnrrvrnnnerrnnnrnnnanrrnrnnnennnsne 20 3 4 Hardware MCGUIFGMIGINS Lea 21 3 4 1 Fe Soe cee ogee NEN AAA E A IEEE DE RSA ERR See se shoe DET NR 21 3 4 2 Slot for the netSCOPE Data Acquisition Cards ccccccsseccceeessseeeeeseeeeeeeeeees 21 3 4 3 Card Height and Panel Cutout NSCP C100 REV90E rrurrrrnnnnnvnnrnnnnnnennnnnnnrenn 22 3 4 4 Power Supply and Host Interface rrrrrrrrnnrrnnnnnrnnrrvrrnnnnnnnnrrrnnrrrnnnnnnnssennnnnnnn 23 netSCOPE Data Acquisition Cards for Real Time Ethernet Installation O
36. Pin Assignment at the RJ45 Socket for netSCOPE Data Acquisition Card or AIFX Pin Signal Transmit Data Transmit Data Receive Data Connected to each other and e mr hevede Connected to each other and e ER terminated to PE through RC circuit DEE Bob Smith Termination Table 23 Ethernet Pin Assignment at the RJ45 Socket for netSCOPE Data Acquisition Card or AIFX gt Note The RJ45 socket is only for use in LAN not for telecommunication circuits 10 1 2 Ethernet Connection Data 2 x 2 Twisted Pair cupric cable CAT5 100 MBit s Length of cable Typ 100 m Table 24 Ethernet Connection Data netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Device Connections 51 71 10 2 Cable Connector 10 2 1 Pin Assignment for Cable Connector Ethernet Only for NSCP C100 RE 90E Pin Assignment for Cable Connector Ethernet X4 Cable 20 pin Ethernet and Status LEDs lem ooo STAO green RE LED COM 0 6 Stat green RE LED COM 1 s omon o ARNT Table 25 Pin Assignment for Cable Connector Ethernet X4 Hi Figure 29 2x20 Pins for NSCP C100 RE 90E netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013
37. Table 17 Table 18 Table 19 Table 20 Table 21 Table 22 Table 23 Table 24 Table 25 Table 26 Table 27 Table 28 Table 29 Table 30 Table 31 Table 32 Table 33 Table 34 Table 35 Table 36 68 71 Required Panel Cutout and Holes for AIFX 22 Requirements Power Supply and Host Interface for netSCOPE Data Acquisition Cards 23 Notes about Installation and Operation 25 Steps for the Software and Hardware Installation the Configuration and for the Diagnosis of a netSCOPE Data Acquisition Card 27 LED Labeling 42 Fix Front Plate Sticker at the NSCP C100 RE 70E 43 LEDs netSCOPE Data Acquisition Cards 49 LEDs netSCOPE Data Acquisition Cards 49 Indicator States 49 Ethernet Pin Assignment at the RJ45 Socket for netSCOPE Data Acquisition Card or AIFX 50 Ethernet Connection Data 50 Pin Assignment for Cable Connector Ethernet X4 51 Pin Assignment at the PCI Bus 52 References PCI Specifications 52 Pin Assignment Mini PCI Express Bus of the NSCP C100 RE 90E Card X1 X2 53 Technical Data NSCP C100 RE 50 55 Technical Data NSCP C100 RE 50E 57 Technical Data NSCP C100 RE 70E 59 Technical Data NSCP C100 RE 80 61 Technical Data NSCP C100 RE 90E 63 Technical Data AIFX RE 64 PCI IDs netSCOPE Data Acquisition Cards on the PCI Bus 65 Supported not supported PCI Bus Commands 65 netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released
38. allation operation and hardware of the netSCOPE data aquistion card PCI PCI Express Low Profile PCI Express Compact PCI and Mini PCI Express under Windows XP Windows Vista Windows 7 and Windows 8 as listed subsequently netSCOPE data aquistion card for Real Time Ethernet PCI NSCP C100 RE 50 PCI Express NSCP C100 RE 50E Low Profile PCle NSCP C100 RE 70E Compact PCI NSCP C100 RE 80 Mini PCI Express NSCP C100 RE 90E for NSCP C100 RE 90E inclusively the AIFX Assembly Interface Ethernet AIFX RE for the Real Time Ethernet system EtherCAT The devices described in this manual are listed in the sections netSCOPE Data Acquisition Cards page 18 The devices are described in detail in the chapters Hardware Installation and Uninstalling page 40 LED Descriptions page 49 Device Connections page 50 and Technical Data page 54 1 1 1 List of Revisions Index Date Chapter Revisions n All Table 1 List of Revisions 1 The AIFX Assembly Interface is also named as Detached Network Interface netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Introduction 6 71 1 1 2 Notes on Hardware Software and Driver Versions 3 Note The hardware revisions and the versions for the firmware the driver or the software listed in t
39. anual accompanying texts documentation etc are protected by German and international copyright law as well as international trade and protection provisions You are not authorized to duplicate these in whole or in part using technical or mechanical methods printing photocopying or other methods to manipulate or transfer using electronic systems without prior written consent You are not permitted to make changes to copyright notices markings trademarks or ownership declarations The included diagrams do not take the patent situation into account The company names and product descriptions included in this document may be trademarks or brands of the respective owners and may be trademarked or patented Any form of further use requires the explicit consent of the respective rights owner 1 3 2 Important Notes The user manual accompanying texts and the documentation were created for the use of the products by qualified experts however errors cannot be ruled out For this reason no guarantee can be made and neither juristic responsibility for erroneous information nor any liability can be assumed Descriptions accompanying texts and documentation included in the user manual do not present a guarantee nor any information about proper use as stipulated in the contract or a warranted feature It cannot be ruled out that the user manual the accompanying texts and the documentation do not correspond exactly to the described features standards
40. azard with high risk which Indicates a Hazardous Situation Which if not will have as consequence death or grievous Avoided will Result in Death or Serious Injury bodily harm if it isn t avoided Indicates a possible hazard with medium risk Indicates a Hazardous Situation Which if not Indicates a minor hazard with medium risk Indicates a Hazardous Situation Which if not which could have as consequence simple Avoided may Result in Minor or Moderate battery if it isn t avoided Injury Indicates a Property Damage Message Indicates a Property Damage Message Note Indicates an important note in the manual Indicates an Important Note in the Manual Table 9 Signal Words which will have as consequence death or Avoided could Result in Death or Serious grievous bodily harm if it isn t avoided Injury In this document all Safety Instructions and Safety Messages are designed according both to the international used safety conventions as well as to the ANSI Z535 standard refer to reference safety S1 2 7 References Safety S1 ANSI Z535 6 2006 American National Standard for Product Safety Information in Product Manuals Instructions and Other Collateral Materials S2 IEC 60950 1 Information technology equipment Safety Part 1 General requirements IEC 60950 1 2005 modified German Edition EN 60950 1 2006 S3 EN 61340 5 1 and EN 61340 5 2 as well as IEC 61340 5 1 and IEC 61340 5 2 netSCOPE Data Acquisition Car
41. cable is correct This means the cable by which you connect the netSCOPE data aquistion card to the Master or Device Configuration gt Check if the netSCOPE data aquistion card is configured properly netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 LED Descriptions 49 71 9 LED Descriptions roet yellow EG cyclic at Device indicates boot error yellow va Bootloader is waiting for booting procedure or device is deinitialized Power supply for the device is missing or hardware defect STAO Capturing process active green Blinking Blinks together with STA1 LED when Identitfy Device is initiated in the netSCOPE for LabVIEW programming interface Capturing process inactive STA1 green all Blinking Blinks together with STAO LED when Identitfy Device is initiated in the netSCOPE for LabVIEW programming interface Error between PCI device and firmware to the PC LINK A connection to the Ethernet exists RJ45 Cho and Ch1 OR The device has no connection to the Ethernet RX TX yellow gt Flashing On The device sends receives Ethernet frames RJ45 ChO and Chi Table 20 LEDs netSCOPE Data Acquisition Cards Fatal Error o color Ste Meaning O Fatal Error Firmware is not able to start because of an hardware problem Table 21 LEDs netSCOPE Data Acquisition Cards
42. cified signaling voltage Operation the netSCOPE data aquistion card with a signaling voltage other than the specified signaling voltage may lead to severe damage to the netSCOPE data aquistion card For detailed information on the supply and signaling voltage of the netSCOPE data aquistion cards described in this manual refer to section Power Supply and Host Interface on page 23 7 2 3 Electrostatically sensitive Devices Adhere to the necessary safety precautions for components that are vulnerable with electrostatic discharge Ba NOTICE Electrostatically sensitive Devices To prevent damage to the PC and the netSCOPE data aquistion card make sure that the netSCOPE data aquistion card is grounded via the endplate and the PC and make sure that you are discharged when you install uninstall the net SCOPE data aquistion card netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Hardware Installation and Uninstalling 42 71 7 3 Installing netSCOPE Data Acquisition Card Electrostatically sensitive Devices 1 Adhere to the necessary safety precautions for components that are vulnerable with electrostatic discharge NOTICE Electrostatically sensitive Devices gt To prevent damage to the PC and the netSCOPE card make sure that the netSCOPE card is grounded via the endplate and the
43. ctrical Shock caused by parts with more than 50V gt Disconnect the power plug of the PC or of the connecting device gt Make sure that the power supply is off at the PC or at the connecting device 4 Open cabinet gt Open the cabinet of the PC or of the connecting device 5 Install the netSCOPE data aquistion card PCI PCI Express or Low Profile PCI Express gt Plug the netSCOPE data aquistion card PCI into a free PCI slot gt Plug the netSCOPE data aquistion card PCI Express or Low Profile PCI Express into a free PCI express slot gt Fix the netSCOPE data aquistion card using the hole intended Compact PCI gt Possibly remove a blank plate gt Put down the ejection lever at the netSCOPE data aquistion card netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Hardware Installation and Uninstalling 44 71 AIFX RE Assembly Interface with Cable Connector Ethernet X1 oa 5 Y Y gt Plug the netSCOPE data aquistion card Compact PCI into a free Compact PCI slot gt Fasten the netSCOPE data aquistion card Tip up the lever and click in v gt Screw the netSCOPE data aquistion card with two screws on the wholes above and below Mini PCI Express gt Plug the basic card NSCP C100 RE 90E into the PCI Express Mini System Connector on the mainboard
44. ds for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Descriptions and Requirements 17 71 3 Descriptions and Requirements 3 1 Introduction to netSCOPE The main characteristics of the netSCOPE data aquistion cards are e Process monitoring e Process documentation e Data acquisition of process values directly from the network e No additional signal wiring e No modification in PLC necessary You can use the netSCOPE data aquistion cards to record and analyze data of Ethernet based automation network or its components conforming to the Ethernet II IEEE 802 3 specification For visualization archiving or machine diagnosis purposes not even network telegrams but process values are captured from the network The netSCOPE data aquistion card is connected to the automation network as a purely passive node Process values are converted to be displayed in LabVIEW for analyzing purposes without changing your PLC program at all All data from the network is recorded with precision timestamp All collected process data is being recorded in a way that it is associated to a certain network cycle communication cycle accurate At any point of time the record is complete allowing examination of information like measurements status and control values by going back in time to find out what had happen in your process A A detailed descript
45. e AIFX RE Standard cutout D Sub 15 2 distance between the holes 37 3 mm Further Information In the data sheet MOD JACK MJIM 2 as well as in section as in section Ethernet AIFX RE on page 33 Table 14 Required Panel Cutout and Holes for AIFX The term X4 is a place name on the netSCOPE data aauistion card netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Descriptions and Requirements 23 71 3 4 4 Power Supply and Host Interface For the power supply and the host interface used for the netSCOPE data aquistion cards PCI PCI Express Low Profile PCI Express Compact PCI and Mini PCI Express you must observe the following requirements netSCOPE Data Supply Voltage Signaling Voltage Host Interface Acquisition Cards Host Interface PCI slot NSCP C100 RE 50 3 3 V de 5 Max 1A 5 Vor 3 3 V NSCP C100 RE 50E 3 3 V dc 5 Max 1 A PCle compatible PCI Express NSCP C100 RE 70E NSCP C100 RE 80 3 3 V dc 5 Max 1 A 5Vor3 3V Compact PCI NSCP C100 RE 90E 3 3 V dc 5 Max 1 A PCle compatible Mini PCI Express Note The power input of the NSCP C100 RE 90E does not comply with the standard specifications Table 15 Requirements Power Supply and Host Interface for netSCOPE Data Acquisition Cards The data in the Table 15 above have the following meaning Suppl
46. ection Schema Capturing and analyzing the Communication between a EtherCAT Master and the EtherCAT Slave 1 20 Figure 2 NSCP C100 RE 50 28 Figure 3 NSCP C100 RE 50E 28 Figure 4 Front Plate for NSCP C100 RE 50 NSCP C100 RE 50E 29 Figure 5 NSCP C100 RE 70E Hardware revision 1 30 Figure 6 Front Plate for NSCP C100 RE 70E 30 Figure 7 NSCP C100 RE 80 31 Figure 8 Front Plate NSCP C100 RE 80 31 Figure 9 Basic Card for NSCP C100 RE 90E 32 Figure 10 Ethernet Assembly Interface AIFX RE 33 Figure 11 Front Side Ethernet Assembly Interface AIFX RE 33 Figure 12 Dimensioning and LED Display Ethernet Assembly Interface AIFX RE 33 Figure 13 Options in the netSCOPE for LabVIEW Autostart Menu 34 Figure 14 net ANALYZER netSCOPE Windows Device Driver Setup Wizard 35 Figure 15 net ANALYZER netSCOPE Windows Device Driver Setup Wizard 35 Figure 16 net ANALYZER netSCOPE Windows Device Driver Setup Wizard 36 Figure 17 Options in the netSCOPE for LabVIEW Autostart Menu 37 Figure 18 netSCOPE for LabVIEW Instrument Driver Directory 37 Figure 19 Options in the netSCOPE for LabVIEW Autostart Menu 38 Figure 20 LabVIEW Directory 38 Figure 21 Options in the netSCOPE for LabVIEW Autostart Menu 39 Figure 22 netSCOPE for LabVIEW Documentation Directory 39 Figure 23 Front Plate Stickers for different netSCOPE Data Acquisition Card Types 42 Figure 24 Mounting the basic Card NSCP C100 RE 90E into the PCI Express Mini System Connector 44 Figure 25
47. elect Open Instrument Driver Directory 34 LabVIEW Instrument Extract the instrument driver zip file to an Driver arbitrary location Preparing Hardware Installation Take precautions on Electrostatically sensitive Electrostatically LL NOTICE Devices sensitive Devices Electrostatically sensitive Devices Make sure that the netSCOPE data aquistion card is grounded via the endplate and the PC and make sure that you are discharged when you install uninstall the netSCOPE data aquistion card 2 2 Glue sticker on the For NSCP C100 RE 50 NSCP C100 RE 50E Installing netSCOPE Data front plate NSCP C100 RE 70E NSCP C100 RE 80 Acquisition Card Glue the sticker on the front plate of the netSCOPE data aquistion card Hardware Settings Installing netSCOPE data aquistion card Take Be ee safety precautions Take safety Electrical Shock Hazard 13 precautions TE Electrical Shock caused by parts with more than 50V Disconnect the power plug of the PC or of the connecting device Make sure that the power supply Is off at the PC or at the connecting device 3 2 Open cabinet Now open the cabinet of the PC or of the Installing netSCOPE Data connecting device Acquisition Card 3 3 Installing netSCOPE Plug in and mount the netSCOPE data data aquistion card aquistion card netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 20
48. ency fields EN 61000 4 8 2010 power frequency magnetic field test EN 61000 6 2 2005 B1 2011 for industrial environments Programm Interface Interface National Instruments NI LabVIEW 2013 Platform Windows 8 7 Vista XP Server Version August 2013 netSCOPE for LabVIEW Instrument Driver V1 0 x x netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Technical Data 62 71 11 1 5 NSCP C100 RE 90E Part Name Part No Description Value NSCP C100 RE 90E 7330 105 netSCOPE data aquistion card Mini PCI Express for for Real Time Ethernet with cable connector Ethernet for Ethernet assembly interface AIFX RE Note The device height and the power input of the netSCOPE data aquistion card Mini PCI Express NSCP C100 RE 90E do not comply with the standard specifications Function Data Acquisition Card for Real Time Ethernet Communication netX 100 processor Controller Integrated Memory AM FLASH Size of the Dual Port Memory 8 MB SDRAM 4 MB serial Flash EPROM 64 KByte Mini PCI Express One Lane Port according to System Interface Bus Type bus spec 2 refer to section Overview page 52 and Pin Assignment for Mini PCI Express Bus page 53 33 MHz Transmission Rate Data Access DPM or DMA Direct Memory Access Width for the data access to the 32 Bit Dual Port Memo
49. er fscommand Help files for the installation program LabVIEW netSCOPE zip with the LabVIEW instrument driver Table 5 Directory Structure of the netSCOPE LabVIEW DVD 1 2 2 Documentation The following documentation overview gives information for which items you can find further information in which manual Available on the netSCOPE LabVIEW DVD User Manual netSCOPE Data Acquisition DOC131006UMXXEN netSCOPE Data Acquisition Cards for Cards for Real Time Ethernet RTE UM xx EN pdf Installation Operation and Hardware Description Operating netSCOPE DOC1310050IXXEN netSCOPE for LabVIEW Ol xx EN pdf Instruction Vis for LabVIEW Manual Table 6 Documentations netSCOPE LabVIEW DVD These documents are available on the DVD delivered with the device underneath the directory Documentation in Adobe Acrobat Reader format PDF or you can download the latest edition of a manual from the website www hilscher com under Support gt Downloads gt Manuals or under Products directly with the information about your product netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Introduction 9 71 1 3 Legal Notes 1 3 1 Copyright Hilscher 2013 Hilscher Gesellschaft f r Systemautomation mbH All rights reserved The images photographs and texts in the accompanying material user m
50. for the data access to the 32 Bit Dual Port Memory DPM History depth and signal count Process Data Interface Unlimited only restricted by PC memory Signal types Input and output process values Ethernet system Supported Real Time Ethernet EtherCAT Ethernet II 100 MBit s Ethernet Frame Types Baud rate Data transport layer Ethernet II IEEE 802 3 Automated symbol import EtherCAT ENI file Ethernet Interface Transmission rate 100 MBit s for EtherCAT Interface Type 100 BASE TX for EtherCAT refer to section Ethernet Interface page 50 Isolation Voltage 1000 VDC tested for 1 minute Full duplex For EtherCAT supported at 100 MBit s For EtherCAT supported For EtherCAT supported Connector 2 RJ45 Socket Ethernet channels 2x RJ45 passive TAP Ethernet delay lt 1 us additional external TAP with zero delay possible Display LED Display System Status LED STAO LED Status 0 duo LED STA1 LED Status 1 duo LED LED Ethernet Link Status yellow LED Ethernet RX TX Status green Refer to chapter LED Descriptions page 49 netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Auto Negotiation gt lt 3 ei Q D O 3 C O dp dp O lt OD Technical Data 57 71 NSCP C100 RE 50E Parameter Value Power supply Supply Voltage 3 3 V dc
51. from National Instruments PCITM PCI EXPRESS and PCIe or MINI PCI are trademarks or registered trademarks of the Peripheral Component Interconnect Special Interest Group PCI SIG CompactPCI is a trademark of the PCI Industrial Manufacturers Group PICMG All other mentioned trademarks are property of their respective legal owners 1 3 7 Obligation to read and understand the Manual amp Important To avoid personal injury and to avoid property damage to your system or to your netSCOPE data aquistion card you must read and understand all instructions in the manual and all accompanying texts to your netSCOPE data aquistion card before installing and operating your netSCOPE data aquistion card First read the Safety Instructions in the safety chapter Obey to all Safety Messages in the manual Keep the product DVD providing the product manuals 1 3 8 Hilscher Software License Agreement When you install the Hilscher software you are asked to read the Hilscher Software License Agreement and explain your acceptance to it netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Safety 12 71 2 Safety 2 1 General Note The documentation in the form of a user manual an operating instruction manual or other manual types as well as the accompanying texts have been crea
52. h 2013 11 Released Public Hilscher 2013 Hardware Installation and Uninstalling 47 71 6 Remove the basic Card Only NSCP C100 RE 90E gt Press down the fastening clips on the upper edge of the basic card until the card flips up Press down the fastening clips red arrows of _ until the card flips up the basic card Figure 27 Demounting the basic Card NSCP C100 RE 90E from the PCI Express Mini System Connector gt Remove the basic card from the PCI Express Mini System Connector After this 7 Close cabinet All netSCOPE data aquistion cards gt Close the cabinet of the PC or connecting device netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Troubleshooting 48 71 8 Troubleshooting 8 1 Instructions for Problem Solving In case of any error follow the instructions for problem solving given here General gt Check if the PC is on gt Check the netSCOPE data aquistion card operating requirements according to the requirements given in the section Notes for Installation and Operation on page 25 LINK LEDs gt Check using the LINK LEDs status whether a connection to the Ethernet is established Therefore use the descriptions on the LINK LEDs in the chapter LED Descriptions beginning from page 49 Cable gt Check that the pin assignment of the
53. his section functionally belong together 1 1 2 1 Hardware netSCOPE Data Acquisition Cards netSCOPE Data Acquisition Card Part No Hardware Revision NSCP C100 RE 70E 7330 102 NSCP C100 RE 90E 7330 105 inclusively Ethernet Assembly Interface AIFX RE Table 2 Reference on Hardware netSCOPE Data Acquisition Cards 1 1 2 2 Drivers and Software Version Path on the netSCOPE LabVIEW DVD netANALYZER Setup netANALYZER netSCOPE 1 5 X x Driver netSCOPE Windows Device Driver Setup exe oe Device Windows XP 32 Bit netANALYZER netSCOPE Driver MSI ner Windows Vista Windows Device Driver X86 msi Windows 7 64 Bit netANALYZER netSCOPE Driver MSI Windows 8 Windows Device Driver X64 msi netSCOPE for LabVIEW Instrument Driver netSCOPE zip Table 3 Reference on Drivers FileName Version en LabVIEW 2013 Platform DVD Set August 2013 Windows 8 7 Vista XP Server Table 4 Reference on Software netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Introduction 7 71 1 1 3 Conventions in this Manual Notes operation instructions and results of operation steps are marked as follows Notes Important lt important note gt Note lt note gt NS lt note where to find further information gt Operation Instructions 1 lt instruction gt 2 lt
54. idity 10 95 relative humidity no condensation permitted Device Dimensions L x W x H 30 7 x 42 3 x 18 5 mm Mounting Installation At the netSCOPE data aquistion card NSCP C100 RE 90E Cable Connector Ethernet X4 RoHS CE Sign CE Sign Emission Immunity Table 34 Technical Data AIFX RE Tested together with the corresponding netSCOPE data aquistion card OD D N JOO netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Technical Data 65 71 11 2 PCI IDs netSCOPE Data Acquisition Cards on the PCI Bus On the PCI bus the netSCOPE data aquistion cards have the following PCI IDs VendorlD Ox15CF Subsystem Vendor ID Ox15CF Subsystem Device ID 0x0012 Table 35 PCI IDs netSCOPE Data Acquisition Cards on the PCI Bus 11 3 Supported PCI Bus Commands From the following table you can see which PCI bus commands are supported by the Hilscher netSCOPE data aquistion cards PCI PCI Express and Low Profile PCI Express o Jo o fo Imempt cknameage ne ro Jo 0 IE HE Specialcycle mm ro Jo 1 Jo vom v ro Jo 1 fi ow v ro f 0 fo mesen mm ro f 0 mesen mo ro ft 1 Jo wemoymed v ro ft tt Memoywite v o fo Ju ems me Reseed me OK EE O Coniguraton ware 7 Po my ad u me oo p p p ewes m Memory Readies w Zopo p je i
55. inside the equipment e If available use a static safe workstation e When not in use store the equipment in appropriate static safe packaging Reference Safety S3 netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Safety 16 71 2 6 Labeling of Safety Messages e The Section Safety Messages at the beginning of a chapter are pinpointed particularly They are highlighted with a specific safety symbol and a signal word according to the degree of endangerment Inside the safety message the danger is exactly named e The Integrated Safety Messages within an instruction description are highlighted with a signal word according to the degree of endangerment and possibly by a principle symbol Inside the safety message the danger is exactly named Safety USA Sort of Warning or Principle Warning of Personal Injury and Property Damage Message USA Warning of Personal Injury As in the scope of the ANSI Z535 Standard for USA instructions to a property damage message may not contain a warning triangle this property damage messages are listed separately for the USA Warning of Lethal Electrical Shock Warning of Damages by Electrostatic Discharge Principle Disconnect the Power Plug Table 8 Safety Symbols and Sort of Warning or Principle Signal Meaning USA Word Indicates a direct h
56. instruction gt or gt lt instruction gt Results Y lt result gt Safety Instructions The labeling of safety and warning instructions is explained separately in chapter Safety in section Labeling of Safety Instructions 1 1 4 Used Terminology netSCOPE data Hilscher netSCOPE data acquisition card based on acquisition card the netX technology NSCP C100 RE 50 Example for the type name of a netSCOPE data aquistion card for Real Time Ethernet netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Introduction 8 71 1 2 Contents of the netSCOPE LabVIEW DVD The netSCOPE LabVIEW DVD for the netSCOPE data aquistion card contains e The netANALYZER netSCOPE Windows Device Driver file for 32 bit and for 64 bit e netSCOPE for LabVIEW Instrument Driver e The documentation 1 netSCOPE User Manual this document 2 netSCOPE Operating Instruction Manual 1 2 1 Directory Structure of the netSCOPE LabVIEW DVD Directory Name Description Root Directory Flash Animation netSCOPE for LabVIEW exe Documentation Documentation in the Acrobat Reader Format PDF Adobe Reader Installation Driver netANALYZER netSCOPE Windows Device Driver for 32 bit for Windows XP and Windows Vista respectively for 64 bit for Windows 7 and Windows 8 netSCOPE for LabVIEW Instrument Driv
57. ion how to use the netSCOPE instrument driver in LabVIEW you find in the Operating Instruction Manual netSCOPE Vis for LabVIEW netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Descriptions and Requirements 18 71 3 2 netSCOPE Data Acquisition Cards netSCOPE Data Acquisition Cards with integrated Ethernet Interface netSCOPE Data Description Acquisition Card NSCP C100 RE 50 netSCOPE data acquisition card PCI for Real Time Ethernet NSCP C100 RE 50E NSCP C100 RE 70E netSCOPE data acquisition card Low Profile PCle for Real Time Ethernet netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Descriptions and Requirements 19 71 netSCOPE Data Description Acquisition Card NSCP C100 RE 80 netSCOPE data acquisition card Compact PCI for Real Time Ethernet Table 10 netSCOPE Data Acquisition Cards with integrated Ethernet Interface The netSCOPE data aquistion cards NSCP C100 RE 50 NSCP C100 RE 50E NSCP C100 RE 7OE and NSCP C100 RE 80 provide an integrated Ethernet interface netSCOPE Data Acquisition Card with AIFX Assembly Interface Ethernet netSCOPE Data Description Acquisition Card NSCP C100 RE 90E netSCOPE data acquisiti
58. ions page 49 Ethernet Interface Channel 0 6 Ethernet Interface Channel 1 Refer also to section Ethernet Interface page 50 Figure 6 Front Plate for NSCP C100 RE 70E netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Device Drawings 31 71 5 3 netSCOPE Data Acquisition Cards Compact PCI NSCP C100 RE 80 System LED gelb gr n yellow green Status LED 0 und 1 rot gr n Status LED 0 and 1 red green Ethernet RJ45 Buchse RJ45 Socket Pin 4 Term 1 Pin 5 Term 1 Channel 0 CH 0 gt Kanal 1 a Channel 1 hilseher Kompakt PCI Bus Compact PCI Bus Auswurfhebel 135 polig 135 pin Ejection Lever Figure 7 NSCP C100 RE 80 Note Device supports Auto Crossover Function Only 100 Mbit s connections gt 100BASE T are supported The figure below shows the front plate of the netSCOPE data aquistion card NSCP C100 RE 80 O Mini B USB Plug not used System LED yellow green Status LED COMO red green Status LED COM1 red green Refer also to chapter LED Descriptions page 49 Ethernet Interface Channel 0 Ethernet Interface Channel 1 Refer also to section Ethernet Interface page 50 Figure 8 Front Plate NSCP C 100 RE 80 netSCOPE Data Acquisition Cards for Real Time Ethernet Insta
59. iption DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Technical Data 58 71 11 1 3 NSCP C100 RE 70E Description netSCOPE data aquistion card Low Profile PCI Express for Real Time Ethernet Low Profile PCle with RTE Function Data Acquisition Card for Real Time Ethernet Communication Type netX 100 processor Controller FLASH 4 MB serial Flash EPROM Size of the Dual Port Memory 64 KByte System Interface Bus Type PCI Express One Lane Port according to bus spec 2 Rev 2 0 and bus spec 3 refer to section Overview page 52 Transmission Rate 2 GBit s Data Access DPM or DMA Direct Memory Access Width for the data access to the 32 Bit Dual Port Memory DPM History depth and signal count Process Data Interface Unlimited only restricted by PC memory Signal types Input and output process values Ethernet system Supported Real Time Ethernet EtherCAT Ethernet II 100 MBit s Ethernet Il IEEE 802 3 Automated symbol import EtherCAT ENI file Transmission rate 100 MBit s for EtherCAT Interface Type 100 BASE TX for EtherCAT refer to section Ethernet Interface page 50 Ethernet Frame Types Baud rate Data transport layer Ethernet Interface Galvanic Isolation isolated Isolation Voltage 1000 VDC tested for 1 minute Full duplex For EtherCAT supported at 100 MBit s For EtherCAT supported For EtherCAT supported 2 RJ45 Socket Ethernet channels 2x
60. llation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Device Drawings 5 4 netSCOPE Data Acquisition Cards Mini PCI Express 5 4 1 NSCP C100 RE 90E Kabelstecker Ethernet System LED Cable Connector Ethernet gelb gr n X4 20 polig 20 pin yellow green Mini PCI Express Bus X1 X2 52 polig Figure 9 Basic Card for NSCP C100 RE 90E 100BASE T are supported PCI Express Bus on page 53 NSCP C100 RE 90E Notes on the Card Height on page 22 netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description Hilscher 2013 DOC131006UMO1EN Revision 1 English 2013 11 Released Public Note Device supports Auto Crossover Function Only 100 Mbit s connections For information on the card height refer to section the Card Height and Panel Cutout 32 71 For the pin assignment of the Mini PCI Express bus to section Pin Assignment for Mini Device Drawings 33 71 5 5 AIFX Assembly Interface Ethernet AIFX RE Only for NSCP C100 RE 90E Ethernet RJ45 Buchse RJ45 Socket Cable Connector Ethernet X1 20 polig 20 pin Kanal 0 Channel 0 CH 0 Kanal 1 E E 2 Channel 1 5 Kabelstecker Ethernet CH 1 ar ic EEE gelb yellow Figure 10 Ethernet Assembly Interface AIFX RE pea Note Assembled device supports Auto Crossover Function Only 100
61. nal guarantees or assurances are made regarding marketability freedom of defect of title integration or usability for certain purposes unless they are required in accordance with the law and cannot be limited Warranty claims are limited to the right to claim rectification netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Introduction 11 71 1 3 5 Export Regulations The delivered product including the technical data is subject to export or import laws as well as the associated regulations of different counters in particular those of Germany and the USA The software may not be exported to countries where this is prohibited by the United States Export Administration Act and its additional provisions You are obligated to comply with the regulations at your personal responsibility We wish to inform you that you may require permission from state authorities to export re export or import the product 1 3 6 Registered Trademarks Windows XP Windows Vista Windows 7 and Windows 8 are registered trademarks of Microsoft Corporation Adobe Acrobat is a registered trademark of the Adobe Systems Incorporated EtherCAT is a registered trademark and a patented technology of Beckhoff Automation GmbH Verl Germany formerly Elektro Beckhoff GmbH LabVIEW is a graphical programming system
62. nally working with electricity must be present concerning the following topics e Safety and health at work e Mounting and connecting of electrical equipment e Measurement and Analysis of electrical functions and systems e Evaluation of the safety of electrical systems and equipment e Installing and Configuring IT systems netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Safety 13 71 2 4 Safety Instructions to avoid Personal Injury To ensure your own personal safety and to avoid personal injury you necessarily must read understand and follow the following safety instructions and safety messages in this manual about danger causing personal injury before you install and operate your netSCOPE data aquistion card 2 4 1 Electrical Shock Hazard The danger of a lethal electrical shock caused by parts with more than 50V may occur if you open the PC cabinet to install the netSCOPE data aquistion card e HAZARDOUS VOLTAGE is present inside of the PC or of the connec ting device into which the netSCOPE data aquistion card is integrated Strictly obey to all safety rules provided by the device s manufacturer in the documentation e First disconnect the power plug of the PC or of the connecting device before you open the cabinet e Make sure that the power supply is off at the PC or at the
63. nnan mo Table 36 Supported not supported PCI Bus Commands i reer _ C BE Bus Command and Byte Enable Signal of PCI netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Annex 66 71 12 Annex 12 1 Matrix Label A matrix label is on the device It contains 3 items 1 Part number 2 Hardware Revision 3 Serial number The figure shows part number 7330 105 hardware revision 1 and serial number 22394 O Part number 2 Hardware Revision G Serial number Figure 30 Matrix Label 12 2 Disposal of Waste Electronic Equipment According to the European Directive 2002 96 EG Waste Electrical and Electronic Equipment WEEE waste electronic equipment may not be disposed of as household waste As a consumer you are legally obliged to dispose of all waste electronic equipment according to national and local regulations Waste Electronic Equipment This product must not be treated as household waste This product must be disposed of at a designated waste electronic equipment collecting point netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Annex 67 71 12 3 List of Figures Figure 1 Conn
64. on card Mini PCI Express for Real Time Ethernet inclusively Ethernet Assembly Interface AIFX RE with Ethernet interface Table 11 netSCOPE Data Acquisition Card with AIFX Assembly Interface Ethernet The netSCOPE data aquistion card NSCP C100 RE 90E is composed of a basic card and an assembly interface AIFX The basic card NSCP C100 RE 90E is equipped with a Cable Connector Ethernet to connect the Ethernet assembly interface AIFX RE Express NSCP C100 RE 90E requires proper connection of the Ethernet Important Operating the netSCOPE data aquistion card Mini PCI assembly interface AIF X RE to the basic card Note The device height and the power input of the netSCOPE data aquistion card NSCP C100 RE 90E do not comply with the standard specifications netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Descriptions and Requirements 20 71 3 3 Recording and analyzing Data Traffic For devices with EtherCAT communication the netSCOPE data aquistion card captures the Ethernet frames provides them with time stamps and analyzes the recorded data So the netSCOPE data aquistion card must be connected over two Ethernet connection cables from the netSCOPE data aquistion card TAP to the Ethernet interface of the EtherCAT Master and to the Ethernet interface of the Slave 1 Master Sla
65. ost Interface PCI PCI Express Compact PCI or Mini PCI Express 2 netSCOPE for LabVIEW Instrument Driver Hardware Installation For the netSCOPE data aquistion card Mini PCI Express NSCP C100 RE 90E Important Operating the NSCP C100 RE 90E requires proper connection of the Ethernet AIFX RE assembly interface to the basic card Table 16 Notes about Installation and Operation netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Getting Started 26 71 4 2 Installation and Configuration netSCOPE Data Acquisition Card The following table describes the steps for the software and hardware installation and for the configuration of a netSCOPE data aquistion card Real Time Ethernet Description For detailed Page information see manual section Installing Driver and Software Install netANALYZER Insert the netSCOPE LabVIEW DVD Software Installation netSCOPE Windows Device Driver select Install Windows Device Driver Open Instrument Driver Directory and follow to the instructions of the installation wizard to install the netANALYZER netSCOPE Windows Device Driver Note If the installation program does not start automatically start the msi or Setup exe program of the netANALYZER netSCOPE Windows Device Driver in the driver folder of the DVD 1 2 Install netSCOPE for S
66. peration and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Table of Contents 3 71 3 5 Software Requirements u uuuu ene el 24 4 GETHING STAR FED kerosene on eer eae ene Snorer mn ore ne thon teers tere EAE 25 4 1 Notes for Installation and Operation nosies 25 4 2 Installation and Configuration netSCOPE Data Acquisition Card 26 5 DETTE VNR 28 5 1 netSCOPE Data Acquisition Cards PCI NSCP C100 RE 50 and PCI Express NSCGP G100 FE SB ee 28 5 2 netSCOPE Data Acquisition Cards Low Profile PCI Express NSCP C100 RE 70E EE NE SE MS NN A E Me 30 5 3 netSCOPE Data Acquisition Cards Compact PCI NSCP C100 RE 80 31 5 4 netSCOPE Data Acquisition Cards Mini PCI Express rrrrranrnrrrrnnrrrrrnnnrrevnnnnnrrnnnnnn 32 5 4 1 NSER GIDOERE IDE ea ee ana 32 5 5 AIFX Assembly Interface Ethernet AIFX RE rrrrrnnnnnenrarennarennnnnnnnnnrnnnnennnnrnnnnnnnnnee 33 6 SOFTWARE INSTALLATION Grease 34 6 1 netSCOPE LabVIEW DVD Autostart Menu rrrrrnrrerrnnreonrnnnenrnnnronnnnnennnnnrnnnnnnennnnne 34 6 2 netANALYZER netSCOPE Windows Device Driver rrrnrrrrnnrrnnnrrnranrrnnnennnnennnnnrn 34 6 3 netSCOPE for LabVIEW Instrument Driver rrrarernnrnornnnenranrrrrnnnnnnnnrnvanennnnnennnnennnnen 37 6 4 Microsoft Software COMPONENMS ccccseeecceeeeeseeeeceeeeeeceeeeceeseeeeeeeeesaeeeesaaeeeeesaaaes 38 6 5 DEMENS 39 7 HARDWARE
67. r LabVIEW Instrument Driver V1 0 x x Windows 8 7 Vista XP Table 33 Technical Data NSCP C100 RE 90E gt X1 X2 corresponds to the Hilscher convention for interface on the top or the bottom side of the netSCOPE Data Acquisition Card netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Technical Data 64 71 11 1 6 AIFX RE Part Name Part No Description Connector Value AIFX RE 2800 100 Ethernet Assembly Interface with Ethernet interface for the netSCOPE data aquistion card NSCP C100 RE 90E Cable Connector Ethernet X1 JST SM20B SRSS TB LF SN Pitch 1 0 mm Interface netSCOPE data aquistion card Galvanic Isolation isolated Isolation Voltage 1000 VDC tested for 1 minute 2 RJ45 Socket Ethernet channels 2x RJ45 passive TAP Ethernet delay lt 1 us Ethernet Interface Connector additional external TAP with zero delay possible Display LED Display System Status LED STAO LED Status 0 duo LED STA1 LED Status 1 duo LED LED Ethernet Link Status yellow LED Ethernet RX TX Status green Refer to chapter LED Descriptions page 49 Power supply Connector Cable Connector Ethernet X1 Environmental Operating temperature range 0 C 70 C Conditions 0 5m s Air flow during measurement Storage temperature range 0 70 C Hum
68. ry DPM History depth and signal count O D Process Data Interface Unlimited only restricted by PC memory Signal types Input and output process values Ethernet System Supported Real Time Ethernet EtherCAT Ethernet II 100 MBit s Ethernet Il IEEE 802 3 EtherCAT ENI file Ethernet Frame Types Baud rate Data transport layer Automated symbol import Ethernet Interface Transmission Rate 100 MBit s for EtherCAT Interface Type 100 BASE TX for EtherCAT refer to section Ethernet Interface page 50 Full duplex For EtherCAT supported at 100 MBit s Auto Negotiation For EtherCAT supported For EtherCAT supported Ethernet Assembly Interface AIFX RE refer to section AIFX RE page 64 Important Operating the netSCOPE data aquistion card NSCP C100 RE 90E requires proper connection of the Ethernet assembly interface AIFX RE to the basic card Connector AIFX RE Cable Connector Ethernet X4 JST BM20B SRDS G TFC Pitch 1 0 mm Time stamp resolution 10 ns Display LED Display SYS System Status LED Power supply Supply Voltage 3 3 V dc 5 refer to section Power Supply and Host Interface page 23 ep lt M re OD Auto Crossover Maximum Current at 800 mA at 3 3 V typically Connector Via Mini PCI Express Bus Operating temperature range 07 55 C netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1
69. s 8 7 Vista XP Server e The netANALYZER netSCOPE Windows Device Driver V 1 5 x x must be installed e The netSCOPE for LabVIEW Instrument Driver must be installed For netSCOPE for LabVIEW the following components must be installed on your PC e Microsoft NET 4 0 e Microsoft Visual C 2008 Redistributable e Microsoft Visual C 2010 Redistributable If these Microsoft components are not installed on your computer use the installation files provided on the netSCOPE LabVIEW DVD The descriptions on how to install the driver and software you find in chapter Software Installation on page 34 Pe ji I 1 hi Fr ki a it netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Getting Started 25 71 4 Getting Started 4 1 Notes for Installation and Operation You must read and obey the following notes about installation and operation of your netSCOPE data aquistion card to guarantee proper installation and an error free operation of your device Description Note Hardware and Software The hardware and software requirements described in chapter 3 must be met Requirements Software Installation The following software and drivers must be installed 1 LabVIEW Version August 2013 2 netANALYZER netSCOPE Windows Device Driver V1 5 x x This is the driver for the H
70. s Device Driver Via this option you can install the net ANALYZER netSCOPE Windows Device Driver e Open Instrument Driver Directory Via this option you can install the netSCOPE for LabVIEW Instrument Driver e Open Documentation Directory Via this option you can access to the documentations netSCOPE User and Operating Instruction Manual 6 2 netANALYZER netSCOPE Windows Device Driver To install the netANALYZER netSCOPE Windows Device Driver proceed as described hereafter 1 Close all programs 2 Enter the netSCOPE LabVIEW DVD in the local DVD ROM drive gt The start screen of the autostart menu is displayed with the following options metSsUlpeE for L3abVIEVV Install Windows Device Driver Open Instrument Driver Directory Open Documentation Directory Fant Data wy EtherCAT ner S15 N15 COMPETENCE IN COMMUNICATION Figure 13 Options in the netSCOPE for LabVIEW Autostart Menu 3 Select Install Windows Device Driver in the autostart menu netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Software Installation 35 71 Note Under Windows you need administration rights for the installation gt The netANALYZER netSCOPE Windows Device Driver Setup Wizard netANALYZER Device Driver appears il netANALYZER Device Driver x64 1 5 1 0 Setu Res
71. ted for the use of the products by educated personnel When using the products all Safety Messages Safety Messages Property Damage Messages and all valid legal regulations have to be obeyed Technical knowledge is presumed The user has to assure that all legal regulations are obeyed 2 2 Intended Use The netSCOPE data aquistion card described in this User Manual each work as a passive Ethernet analyzer in RT Ethernet systems The netSCOPE data aquistion card analyze the data in a communication link and capture the incoming Ethernet frames netSCOPE data acquisition card PCI for Real Time Ethernet NSCP C100 RE 50 netSCOPE data acquisition card PCI Express for Real Time Ethernet NSCP C100 RE 50E netSCOPE data acquisition card Low Profile PCle for Real Time Ethernet NSCP C100 RE 70E netSCOPE data acquisition card netSCOPE data acquisition card Compact PCI for Real Time Ethernet PCI for Real Time Ethernet NSCP C100 RE 80 epee ee eats ae ee data acquisition card Mini PCI for Express Real Time Ethernet NSCP C100 RE 90E inclusively Ethernet Assembly Interface AIF X RE Table 7 netSCOPE Data Acquisition Cards If the netSCOPE data aquistion cards are used outside of the scope described in this user manual an error free function can not be guaranteed 2 3 Personnel Qualification The netSCOPE data aquistion card must only be installed configured and removed by qualified personnel Job specific technical skills for people professio
72. tion Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Hardware Installation and Uninstalling 40 71 7 Hardware Installation and Uninstalling To install uninstall the netSCOPE data aquistion cards for Real Time Ethernet PCI NSCP C100 RE 50 PCI Express NSCP C100 REI50E Low Profile PCle NSCP C100 RE 70E Compact PCI NSCP C100 RE 80 Mini PCI Express NSCP C100 RE 90E handle as described in the sections hereafter The device drawing of your netSCOPE data aquistion card gives information on the manual control elements of your device This user manual provides descriptions of the installation of the software and the installation operation and hardware of the netSCOPE data aquistion cards PCI PCI Express Low Profile PCI Express Compact PCI and Mini PCI Express under Windows XP Windows Vista Windows 7 and Windows 8 as listed subsequently For the installation uninstalling and replacement of the netSCOPE data aquistion card check any notes in the overview in chapter Getting Started on page 25 7 1 Safety Messages on Personal Injury Obey to the following safety messages on personal injury when installing uninstalling or replacing the netSCOPE data aquistion card 7 1 1 Electrical Shock Hazard Lethal Electrical Shock caused by parts with more than 50V HAZARDOUS VOLTAGE inside of the PC or of the connecting device
73. tions 53 71 10 3 3 Pin Assignment for Mini PCI Express Bus NSCP C100 RE 90E Only for NSCP C100 RE 90E X1 X2 Fran iat Pino s gt 2 sy ooo por usea ar a 45 notused 49 ldnotused ad ET tnot usa 37 motused 35 Je PERpO PETpO 5 rem m alee REFCLK 9 GND gt 7 CLKREQ not used on 1 notused gt Be Tag WW 46 IO SYNCO gt O ma em o Bootstart w an 38 USB D disabled not used Z O Z O O USB_D disabled not used not used not used not used 24 motused o PERST not used 2 I oo 14 not used not used not used not used Table 28 Pin Assignment Mini PCI Express Bus of the NSCP C100 RE 90E Card X1 X2 Unless otherwise noted the pin assignment for Mini PCI Express bus X1 X2 described in Table 28 corresponds to the bus specification for Mini PCI Express bus spec 6 Rev 1 2 Section 3 3 Please note the following deviations from the standard assignment The Pins 6 28 48 24 36 and 38 are not used As pin 24 is not used the netSCOPE data aquistion card NSCP C100 RE 90E can be used together with main boards according to any earlier revision 1 1 and 1 2 of the Mini PCI Express specification bus spec 6 as well as to the latest revision 2 0 The USB connector Pins 36 and 38 at the Mini PCI Express Bus of the netSCOPE data aquistion card NSCP C100 RE 90E is directly connected to the CPU of
74. ue to high supply voltage to your netSCOPE data aquistion card you must observe the following instructions These instructions apply to all netSCOPE data aquistion cards described in this manual The netSCOPE data aquistion card may only be operated with the specified supply voltage Make sure that the limits of the allowed range for the supply voltage are not exceeded A supply voltage above the upper limit can cause severe damage to the netSCOPE data aquistion card A supply voltage below the lower limit can cause malfunction in the netSCOPE data aquistion card The allowed range for the supply voltage is defined by the tolerances specified in this manual For the netSCOPE data aquistion cards listed hereafter adhere specifically The netSCOPE data aquistion card e NSCP C100 RE 50 e NSCP C100 RE 5OE e NSCP C100 RE 70E e NSCP C100 RE 80 e NSCP C100 RE 90E may not be powered by a 5V supply voltage The netSCOPE data aquistion card may only be powered by a 3 3 V dc 5 supply voltage The data on the mandatory supply voltage for the netSCOPE data aquistion cards described in this manual you find in section Power Supply and Host Interface on page 23 There the required and permitted supply voltage is provided by device type inclusively the permitted tolerance range 2 5 2 Device Destruction by exceeding allowed Signaling Voltage To avoid device destruction due to high signal voltage to your netSCOPE data aquistion card you must
75. uming the netANALYZER Device Driver x64 1 5 1 0 Setup Wizard The Setup Wizard will complete the installation of netAMALYZER Device Driver x64 1 5 1 0 on your computer Click Install to continue or Cancel to exit the Setup Wizard Figure 14 netANALYZER netSCOPE Windows Device Driver Setup Wizard 4 Click on Install The installation is started Please wait while the Setup Wizard installs netANALYZER Device Driver x64 1 5 1 0 Figure 15 netANALYZER netSCOPE Windows Device Driver Setup Wizard netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Software Installation 36 71 Completed the netANALYZER Device Driver x64 1 5 1 0 Setup Wizard Click the Finish button to exit the Setup Wizard Back Cancel Figure 16 netANALYZER netSCOPE Windows Device Driver Setup Wizard gt Click Finish 2 The netANALYZER netSCOPE Windows Device Driver installation is complete netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Software Installation 37 71 6 3 netSCOPE for LabVIEW Instrument Driver To install the netSCOPE for LabVIEW Instrument Driver proceed as described hereafter
76. unt Signal types Input and output process values Supported Real Time Ethernet EtherCAT system Interface Type 100 BASE TX for EtherCAT refer to section Ethernet Interface page 50 Isolation Voltage 1000 VDC tested for 1 minute Full duplex For EtherCAT supported at 100 MBit s Integrated Memory System Interface JJ gt Ethernet System Ethernet channels 2x RJ45 passive TAP Ethernet delay lt 1 us MT ert anona a sweden STAO LED Status 0 duo LED STA1 LED Status 1 duo LED netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Technical Data 55 71 NSCP C100 RE 50 Parameter Ethernet Link Status Ethernet RX TX Status Power supply Supply Voltage 3 3 V dc 5 refer to section Power Supply and Host Interface page 23 Maximum Current at 3 3 V 650 mA typically Connector sid Connector Via PCI Bus Environmental EPer ZUBE range KE I KE I Storage temperature range 0 C 70 C Humidity 10 95 relative humidity 10 95 relative humidity no condensation permitted Device Dimensions L x W x H 120 0 x 86 x 18 5 mm from hardware revision 3 Mounting Installation PCI slot 3 3 V refer to section Slot for the netSCOPE Data Cards page 21 Ros me 9 Emission EN 55011 2009 A1 2010 CISPR 11 2009 Class A Radio disturbance characteristics
77. ve 1 Ethernet gt Ethernet netSCOPE Card Ethernet Figure 1 Connection Schema Capturing and analyzing the Communication between a EtherCAT Master and the EtherCAT Slave 1 netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Descriptions and Requirements 21 71 3 4 Hardware Requirements 3 4 1 PC PC with the following specification Intel compatible CPU approx 2 GHz or faster 1 GB RAM or more e 1 PCI slot refer to section Slot for the netSCOPE Data Acquisition Cards page 21 Note The netSCOPE data aquistion card NSCP C100 RE 90E can be used together with main boards according to any earlier revision 1 1 and 1 2 of the Mini PCI Express specification bus spec 6 as well as to the latest revision 2 0 For the reference for bus spec 6 for the bus specification for Mini PCI Express refer to section References PCI Specifications on page 52 of this manual 3 4 2 Slot for the netSCOPE Data Acquisition Cards PC with slot 3 3 V for netSCOPE data aquistion cards PCI PCI Express Low Profile PCI Express Compact PCI and Mini PCI Express m re Acquisition Cards isi NSCP C100 RE 50 PCI slot 3 3 V NSCP C100 RE 50E PCI Express x1 slot 3 3 V reo VEE E x1 One Lane bus spec 3 110 Compact PCI Slot 38 3 V 200 Compact PCI Slot 38
78. y Voltage The required and permissible supply voltage at the netSCOPE data aquistion card PCI PCI Express Low Profile PCI Express Compact PCI and Mini PCI Express Note To ensure that the compatibility between different systems is guaran teed providing a maximum of 1 A for 3 3 VDC 5 is recommended The typical current depends on the type of the netSCOPE data aquistion card For detailed values on the typical current see section Technical Data netSCOPE Data Acquisition Cards on page 54 Signaling Voltage Host Interface The required or tolerated signaling voltage at the I O signal pins at the PCI bus of the netSCOPE PCI card PCI express bus of the netSCOPE PCle and Low Profile PCle cards Compact PCI bus of the netSCOPE Compact PCI card Mini PCI Express bus of the netSCOPE Mini PCI Express card Host Interface PCI slot Type of the host interface netSCOPE Data Acquisition Cards for Real Time Ethernet Installation Operation and Hardware Description DOC131006UMO1EN Revision 1 English 2013 11 Released Public Hilscher 2013 Descriptions and Requirements 24 71 3 5 Software Requirements e Operating System Windows XP Professional SP3 32 bit and 64 bit Version Windows Vista 32 bit and 64 bit Version Windows 7 32 bit and 64 bit Version Windows 8 32 bit and 64 bit Version e The program LabVIEW Version August 2013 must be installed NI LabVIEW 2013 Platform Window
79. y negligent violation of significant contractual obligations Indemnity claims for the violation of significant contractual obligations are limited to damages that are foreseeable and typical for this type of contract It is strictly prohibited to use the software in the following areas e for military purposes or in weapon systems e for the design construction maintenance or operation of nuclear facilities e in air traffic control systems air traffic or air traffic Communication systems e in life support systems e in systems in which failures in the software could lead to personal injury or injuries leading to death We inform you that the software was not developed for use in dangerous environments requiring fail proof control mechanisms Use of the software in such an environment occurs at your own risk No liability is assumed for damages or losses due to unauthorized use 1 3 4 Warranty Although the hardware and software was developed with utmost care and tested intensively Hilscher Gesellschaft fur Systemautomation mbH does not guarantee its suitability for any purpose not confirmed in writing It cannot be guaranteed that the hardware and software will meet your requirements that the use of the software operates without interruption and that the software is free of errors No guarantee is made regarding infringements violations of patents rights of ownership or the freedom from interference by third parties No additio