Home
        User Manual
         Contents
1.             SE   5 0 u      Ready or Tank Filling    Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system 23    Consumables replacement       Consumables replacement    Replacing Progard Pack    When the system shows the icon  e order a new Progard Pack     When the system displays the yellow alert E cora replace the pack     Note   it is recommended to replace the Vent Filter at this time  Additionally  it is  recommended to clean the feed water strainer        Removing exhausted pack    Verify or put the system in Standby by pressing  amp    MODE key   1 Unlock the locking handle by pulling up   2 Pull out the pack     Note   when the Progard Pack is removed  a red color display appears  This is normal  This  will go away when a new pack Is installed     26 Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    Consumables replacement       Placing new pack    Remove the new pack from its shipping box  Remove the 2 protective caps from the  ports at the top of the pack     A Locate the o ring inside each port  Make sure the o rings are push inside  against the inner edge of the ports     1 Mount the bottom of the Pack onto the small hole in the cabinet   Swing the rest of the Pack so that the top of the Pack aligns with pack locking handle  and the cabinet ports   2 Push the top of the Pack in place   3 Push the Pack locking handle down to secure the Pack   e The new pack is detected   e The display prompts you to s
2.            FTFFIZSS1    REW 1 0                               Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system   FTPF12381   V 1 0   12 11    
3.    User Manual  Elix   Essential 3  5  10  15  UV  system  RIOs    Essential 5  8  16  24 system          Preface    Congratulations     Thank you for buying our Water Purification System   For any observation or request  please contact Millipore     By Internet    The Millipore Internet Site can be used to find addresses  telephone fax numbers and other  information     Internet Site Address     www millipore com  www millipore com techservice  www millipore com lab_water    Manufacturing Site    Millipore SAS  67120 Molsheim  France    Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system 1    Preface    Safety information    Your water system should be operated according to the instructions in this manual  In  particular  the hydraulic and electrical specifications should be followed and met  It is  important to use this equipment as specified in this manual  using this equipment in a  different manner may impair the safety precautions of the water system     This ATTENTION symbol is used to refer to instructions in this manual that need to  be done carefully        These symbols are used to indicate that proper safety equipment has to be used     Protective glasses and gloves must be worn     This UV RADIATION sticker is used to refer to a position on the water system  Cabinet or inside of it where exposure to UV light is possible        This DANGER sticker is used to refer to a position on the water system Cabinet or  inside of it that could b
4.   RiOs    Essential 5  8  16  24 system    Optional equipment catalog numbers    Name   PE RESERVOIR 30   30 L PE UNDERBENCH TANK  PE RESERVOIR 60   PE RESERVOIR 100   100 L PE UNDERBENCH TANK  SDS 200   TANK CONNECTION KIT  TANK LEVEL SPLITTER    ASM 2011  WATER SENSOR    WALL MTG BRACKET  EXTERNAL RELAY KIT  SANITIZATION KIT    System s catalog numbers    Name   Elix Essential 3   Elix Essential 5   Elix Essential 10  Elix Essential 15  Elix Essential 3 UV  Elix Essential 5 UV  Elix Essential 10 UV  Elix Essential 15 UV  RiOs Essential 5  RiOs Essential 8  RiOs Essential 16  RiOs Essential 24    Description   Round polyethylene reservoir  Round under bench reservoir  Round polyethylene reservoir  Round polyethylene reservoir  Square under bench reservoir  200 L SDS tank alone  Connection kit AFS to SDS  Tank level display splitter    Automatic sanitization module  Water leak detector    System wall mounting bracket  Alert alarm relay  System s sanitization    Description    With UV lamp 254 nm  With UV lamp 254 nm  With UV lamp 254 nm  With UV lamp 254 nm    Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    Item catalog numbers    Reference  TANKPEO30  TANKBI030  TANKPEO60  TANKPE100  ZBITANKO1  TANK00200  SDSAFSCKT  ZSTWINLX2    TANKASMES  ZFWATDET4    SYSTFIXO1  KITRELESS  SANKITOO4    Reference   ZLXE003WW  ZLXEOOS WW  ZLXEO1OWW  ZLXEO15WW  ZLXEVO3WW  ZIXEVOSWW  ZLXEVIOWW  ZLXEV15WW  ZROEOOSWW  ZROEOO8WW  ZROEO16WW  ZROEO24WW    51     
5.  2011 Millipore Corporation  Printed in France  All rights reserved  This book or parts  thereof may not be reproduced in any form without the written permission of the  publishers     Trademarks    Millipore is registered trademark of Millipore Corporation    Elix  Progard and Millitrack are registered trademarks of Millipore Corporation  RiOs is a  trademark of Millipore Corporation    The  M  Mark and are a trademark of Millipore Corporation    Velcro is a registered trademark of Velcro Industries  B V    All other trademarks are trademarks of their respective manufacturers     46 Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    Legal information    Product warranty and limitation of liability    The applicable warranty and limitation of liability for the products listed in this publication  may be found at http   www millipore com ec cp3 terms within the  Terms and Conditions  of Sale  applicable to your purchase transaction     Recycling       Directive 2002 96 EC  For European users only    The symbol    crossed bin  on a product or its packaging indicates that  the product should not be treated like household waste when  discarded  Instead the product should be disposed of at a location  that handles discarded electric or electronic equipment     Proper disposal of equipment containing electric or electronic  components will help to reduce pollution effects to the environment  or to human health  Proper recycling of these products he
6.  IL Uo      6 Change month with  arrows  J gt   and press           n   mg    11  Change with arrows       JT    and press  amp      21    System    View operation parameters    In Ready or Tank filling  press and hold 2 sec on left or right arrow  I gt   to access  operation parameters     Tap water feed conductivity value can  be displayed by pressing E     gi bom      RO feed water conductivity value can  be displayed by pressing E     695      1    RO water temperature value can be        de    displayed by pressing E  16 0 ke      dJ    RO pump pressure value can be  displayed by pressing       d4 45    RO   rejection value can be displayed  by pressing       d3 566       On Elix Essential  RO permeate water  conductivity value can be displayed by    pressing E     CA A AAA AA    ES    do    Note   the product water quality and temperature are displayed on the main display view     On RiOs Essential  the RO permeate water On Elix Essential  the resistivity or  conductivity is shown on the main display  conductivity is shown on the main display     To OL     ho     E 250  ODE 2  E om    DE o    Press arrow to view temperature  Press arrow to view temperature     22 Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    System    Software navigation map             The software map below shows the main menus available in the system     Standby or maintenance          FTF  Press    IL       to navigate          Es N Press GI     JAE E   to nad 
7.  e The outline is blinking when  the tank is empty           ha           16 Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    System    Software modes    The different software modes are described below with some examples     e System is in Standby or maintenance   Le Tank is 70    e Tool icon indicates maintenance   e System is in Standby or maintenance     e Tool icon indicates maintenance   e Values area indicates Cl2 sanitization start     e Gears icon indicates parameters     e Values area indicates ECO mode setting   e System is in Ready or in Tank filling or in Tank full   Le Tank is 90    e Product water resistivity is 15 MQ cm   e Tank is 70         malo Product water resistivity is 15 MQ cm   IG sL  e The Progard pack must be changed in 15 days  order a new  Progard pack     H    RP  l  ry     CS     Py      mm H   WW  M  C  Ca       Ca  i              e Yellow color display and Lg  the Progard pack must be changed   e Product water resistivity is 15 MQ cm     e Yellow color display and EB  the CL2 cleaning must be started   e Product water resistivity is 15 MQ cm           e    e Yellow color display  Er 20 and EN   e The system has detected a minor problem that does not affect  the normal operation  Refer to section Error codes at page 38     e Red color display and ES   e Ihe system has detected a dysfunction when operating in normal  conditions  In this example  system has detected a low feed water  pressure and has stopped  M
8. 5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    Error messages    Basic troubleshooting    Icon or error          Er 02    Er 20    Er 24    Er 26    What to do    e Product water resistivity  lt  set point or RO permeate water  conductivity  gt  set point    e Verify the consumables have been replaced    e Low feed water pressure is detected  0 5 bar     e Verify the feed water faucet is opened    e Verify the feed water pressure Is in specification    e Verify the feed water pressure regulator is well adjusted or is working  properly  if installed      e Water leak is detected     e Feed water temperature  gt  35  C    e Verify that the feed water temperature is really greater than 35   C  See  the feed water quality requirements to operate the system in compliance  with the manufacturer specifications    e Network cable is unplugged  cancel the warning or plug the Ethernet  cable    e Replace UV lamp 254 nm  the UV lamp is exhausted    e Contact your Service Representative for replacing the UV Lamp 254 nm    e Replace UV lamp ASM  the UV lamp is exhausted    e Contact your Service Representative for replacing the UV Lamp ASM     Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system 39    Chemical and technical specifications       Chemical and technical specifications    Specifications and requirements    Product water specifications    lon rejection  RiOs Essential    Particle rejection  RiOs Essential   Resistivity   Conductiv
9. cement 25  Replacing rogard  packard ni ria 26   Sanitizationsand clean arcanos 29  Sanitizing RO membranes with  chlorine BI  une 30  Cleaning RO membranes with acid base  pH     31   Other HERE 33  Saving display energy   ECO Modena 34  System is not used for a long time   Lab Closed    35   ECO ME 37  o A A 38  Basic tro0blesn601Ng avivado iio 39   Chemical and technical Specification Susie 41  Specifications and  requirements ii 42   CUA MACON ie en RARE 45  Kack Re NS MR Ne M ie RU 46  CORRE A e O ee eer eee rete 46    s ie    mark ee a ei tan 46  Product warranty and limitation of liability caricia di 47  K  erel een O 47    8 Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    Table of conte    eau ee e Belle    Cons  mables catalog AUS a E ai  Optional consumables catalog numbers    rs  Optional equipment Catalog numbers  a  Systems catalog UNO CIS En een    Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    nts    Items needed       Items needed    Items checklist    Verify that all items are available before beginning the installation   See the    Content list    for more details     e Water system unit  A    e User manual and Quick Reference Guide  B   e External power supply  C    e Progard Pack  D    e Accessories bag with     e Tubings   e Fittings   e Power cord   e Eloow tubing guides       12 Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    Items needed    M
10. e    Er 03 RO permeate conductivity  gt  set point Contact your service representative   Er 04 RO 9  rejection  lt  set point Contact your service representative   Er 05 RO Feed water conductivity  lt  min Contact your service representative   Er 06 RO Feed water conductivity  gt  max Contact your service representative   Er 07 RO permeate temperature  lt  min Contact your service representative   Er 08 RO permeate temperature  gt  max Contact your service representative   Er 09 RO permeate conductivity  lt  min Contact your service representative   Er 10 RO permeate conductivity  gt  max Contact your service representative   Er 11 EDI product temperature  lt  min  Elix  Contact your service representative   Er 12 EDI product temperature  gt  max  Elix   Contact your service representative   Er 13 EDI product resistivity  lt  min  Elix  Contact your service representative   Er 14 EDI product resistivity  gt  max  Elix  Contact your service representative   Er 20 Network cable is unplugged See next page    Er 21 No response from DHCP server Contact your network administrator   Er 22 Incorrect IP address Contact your network administrator   Er 24 Replace UV lamp 254 nm  Elix  See next page    Er 25 Check UV lamp 254 nm  Elix  Contact your service representative   Er 26 Replace UV lamp ASM See next page    Er 27 Check UV lamp ASM Contact your service representative     Er 30 No response from cold fire microprocessor Contact your service representative     38 Elix   Essential 3  
11. e and operation    Noise level       Chemical and technical specifications             14 kg  19 kg  12 2 kg  17 kg    100 240 VAC  50 60 Hz  150 W     lt  2000 m   5   40   C   5 40   C       2    lt  80  without condensation   lt  50 db at 1 meter    Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system 43    Legal information       Legal information    Notice    The information in this document is subject to change without notice and should not be  construed as a commitment by Millipore Corporation  Millipore Corporation assumes no  responsibility for any errors that might appear in this document  This manual is believed to  be complete and accurate at the time of publication  In no event shall Millipore  Corporation be liable for incidental or consequential damages in connection with or arising  from the use of this manual     We manufacture and sell water purification systems designed to produce pure or ultra pure  water with specific characteristics  uS cm  T  TOC  CFU ml  Eu ml  when it leaves the water  purification system provided that it s fed with water quality within specifications  and  properly maintained as required by the supplier     We do not warrant these systems for any specific applications  It is up to the end user to  determine if the quality of the water produced by our systems matches his expectations    fits with norms legal requirements and to bear responsibility resulting from the usage of   the water     Copyright      
12. e hazardous     This ELECTRICAL GROUND sticker is used to refer to a position on the water system  Cabinet or inside where an electrical ground connection is made        This ELECTRICAL DANGER sticker is used to refer to a position on the water system  Cabinet or inside where an electrical danger could exist         gt  P  gt   amp  COOP    IMPORTANT     Your water system should be installed and operated in a clean and dry area  Please refer to  the environment requirements page at the end of this manual     Your water system is not designed for domestic use     Powering off the water system for a long period of time can discharge the battery  used by the time keeper  time and date can be lost  If the water system is shut off for  a long period of time  use the lab closed mode or go through an installation procedure  of the water system  Contact your Service Representative     Save the system s history frequently   every 3 or 6 months     2 Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    Preface    Documentation usage    The instruction manual found with your water purification system is important for a good  usage and the maintenance in compliance with the manufacturer specifications     Your water system is delivered with two documents  and these are     e    user manual which describes all specifications  operations and functions of the water  system     e    quick guide that describes quick access to maintenance and operating informati
13. ed  Display with all symbols is represented below     Item Description                1 System s status icons are          e Maintenance or tool     the system is in Standby or  maintenance can be started           e Configuration or gears     configuration parameters such  as set points can be changed           e Process or hour glass        can be done     the system is busy  No action                2 Warning maintenance or alarm  from  left to right  are displayed to indicate    that     e CL2 sanitization is required   El perform the sanitization of the    RO cartridge           e System sanitization is required     e Product water resistivity Is    below set point           detected     e Low feed water pressure Is             e Water is detected  if water        sensor installed            e Contact Millipore      gt        Description  Values area is used to display  e Water quality measures   e Software menu and  configuration values   e Error code numbers   Units are  e   or minutes   e MaQ cm or megOhm centimeter     p macm   US cm or micro siemens by  Som                            i centimetre    e   C or temperature degree  Celsius       or percentage   Consumables status icons are  used to indicate that a  maintenance action Is  required    e For more information  refer to  the Quick Guide or the  Consumables Replacement  section in this document   Tank water level is represented  by 10 bars  Each bar represents  10  of the total volume of  water in the tank   
14. illitrack   Software   option    Millitrack Software is an embedded GUI  graphical user interface  developed with AJAX   Asynchronous JavaScript and XML  techniques that generate interactive web pages  through a point to point computer or direct network connection using TCP IP Ethernet  protocol     Millitrack Software allows a lab user to download or view instantaneously quality data  through their internet browser for rapid monitoring of his water purification system     Millitrack Software users have also real time remote access to interactive web pages  through standard TCP IP network describing water purification system status   configuration  instant quality parameters  settings  identification and Dashboard     Key Benefits    e Native Web graphical user interface    e Real time and remote Dashboard of water systems    e XML data format available for print or download to any spreadsheet database     e Compatible with any lab data management system such as LIMS  ELN  SDMS ECM     M    INSTANT QUALITY      SYSTEM INFORMATION ACME MEASURES  System Type Elix 10 Elix Resistivity 10 0 MQ cm  Catalogue Number CATOO1 Elix Temperature 25 0 C  Serial Number F2BA12345    System Version 1 14  Date 25 09 2011    Time 18 22 34  L    SAVE A COPY      USER INFORMATION    Manager les  PRINTER FRIENDLY      Company    Department    Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system 13       System    Display icons    Know how to interpret each icon display
15. ity   Total Organic Carbon  TOC    Micro organisms for Elix   Micro organisms for Elix UV   Dissolved silica   System and reservoir max length tubing    Product water flow rates    Elix Essential 3  UV  system  Elix Essential 5  UV  system  Elix Essential 10  UV  system  Elix Essential 15  UV  system  RiOs Essential 5 system   RiOs Essential 8 system   RiOs Essential 16 system  RiQs Essential 24 system    Feed water quality requirements    Pressure   Flow rate   Type   Temperature   Conductivity   pH   Langelier Saturation Index  LSI   Free total chlorine     gt  95     gt  99     gt  5 MO em   25   C   lt  0 2 uS cm   25   C   lt  30 ppb    lt  100 cfu mL    lt  10 cfu mL    lt  5 ppb   6m    3 L h  5 L h  10 L h  15 L h  5 L h  8 L h  16 L h  24 L h    1   6 bar    gt  5 L min at 2 bar   Potable   5  35  C   100   2000 uS cm at 25   C  4  10    lt  0 3    lt  3 ppm    42 Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    Water system dimensions    339         133     470   18 5           Water system weight    Dry weight  Elix Essential 3  5  10  15 UV   Operating weight  Elix Essential 3  5  10  15 UV     Dry weight  RiOs Essential 5  8  16  24     Operating weight  RiOs Essential 5  8  16  24     Electrical specifications    Voltage  Frequency  Power consumption    Environmental requirements    Altitude   Ambient operating temperature  Ambient storage temperature  Installation category   Pollution degree    Relative humidity during storag
16. lps in  environmental preservation and helps to protect natural resources   For more information about recycling of products containing electric  or electronic components  please contact your local recycling  representative or organization     Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system 47    Item catalog numbers       Item catalog numbers    Consumables catalog numbers    Name  PROGARD T2    PROGARD T2 WITHOUT SILVER    Description  Pre treatment pack  Pre treatment pack    PROGARD T2 WITHOUT POLYPHOSPHATE Pre treatment pack  PROGARD T2 WITHOUT POLYPHOSPHATE    WITHOUT SILVER    SANITIZATION TABLETS  SANITIZATION TABLETS   US only  SANITIZATION TABLETS   Canada only    RO ACID CLEANER  RO BASE CLEANER    Pre treatment pack    Reference  PROGOTOS2  PROGOTOS2US  PROGOTNP2    PROGOTNP2US    Chlorine tablets  50 per pack  ZWCLO1F50    Acid pouch  12 per pack   Base pouch  12 per pack     PE RESERVOIR VENT FILTER SODA LIME For type 2 water    PE RESERVOIR VENT FILTER 0 22 um    UV LAMP 254 NM    Membrane filter    Optional consumables catalog numbers    Name    PACK SUPPORT  PREPAK    PREPAK WITHOUT SILVER    50    Description  Ext  pre treatment bracket  Ext  pre treatment pack  Ext  pre treatment pack    Chlorine tablets  24 per pack  5874316024  Chlorine tablets  24 per pack  5874316024C    ZWACIDO12  ZWBASEO12    TANKMPKO2  TANKMPK22    ZLXUVLPO1    Reference  ZFPACKSP2  PRPK00001  PRPK00001US    Elix   Essential 3  5  10  15  UV  system 
17. ng can be done  A packaged chemical is available    for this type of cleaning  See the Ordering information section at the end  of this document     Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    System    Maintenance information    Some information can be shown on the display     CL2       Fai  EL o In this view  the chlorine sanitization can be performed     PH       X       In this view  the acid or base cleaning can be performed     SAN    In this view  the system s sanitization can be performed by a  qualified service representative        un  D  3    LF 02       In this view  the UV Lamp 254 nm lifetime can be reset once it  has been changed by a qualified service representative     r   N  Ca  nu    LF 03    In this view  the UV Lamp ASM lifetime  if installed and  activated  can be reset once it has been changed by a qualified  service representative        m   N  Ca  Lu      LAbC  RABEN min    L La   In this menu  the Lab Closed mode can be activated        Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system 19    System    Configure system parameters Fd    Access and configure all system parameters     Sn cpp      cone    z  6093    Bn ALE       Eu IPAdg  gn  Pdf  E      cn    em  u    20    SP 01    Set point for the tank level where the water system goes in Tank  Filling     SP 02    Set point for the RO   Rejection  Below this set point  an alarm is  indicated  This measurement indicates the perce
18. nt of ions removed  by the RO relative to the amount of ions entering it     SP 03    Set point for the resistivity or conductivity for product water   Below this set point  an alarm is indicated     DATE    Menu where date and time can be adjusted     IP AD   used with Millitrack software    Menu where the actual IP address can be viewed     IP DF   used with Millitrack software    Menu where the actual IP address can be reset and switched to  the default one     ECO    Menu where the display energy saving mode can be activated or  deactivated     ASM    Menu where Automatic Sanitization Module can be activated     Cue    Restricted menu accessible with a code and used for Service     Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    System    An example of a configuration change  the DATE  YYYY  MM  DD  and TIME  00 00      E    1 System is in STANDBY  mode  Press on right    arrow  Ir      Eure Q    4 Press  amp  to enter dAtE  menu        E429    7 Change day with arrows    CI  and press Y     go Hour V    9 Set the time  Press       Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system       ri    tec      E    2 In maintenance menu     press           ES 25 ro    5 Change year with arrows       I  gt   and press       Bn Ant      8 The date is set now     Esopo      10  Change with arrows       JT    and press E        Econ i      3 Press on right arrow  I  until the date  menu is displayed     so mn N      
19. on     It may be necessary for to reference these documents for maintenance or other procedures  with the water system  It is recommended to store these documents in such way that they  can be quickly located and where they will not be damaged     A plastic folder provided with the water system  Use this to safety store the documents   You can stick the side of the plastic folder on the side of the water system and place the  documents in there if desired     N     a   AS   Ia       Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system 3    Preface    System overview    The water system and its different modules are described here        Item Description Item Description  1 System name and type 6 Electrical connections  2 Display and keypad 7 System s hydraulic connections  3  Progard   Pretreatment Pack location 8 System ID and serial number  4 Locking handle 9 External power supply   5 Sanitization cleaning port      For powering off the system  disconnect the power cord from the power socket  The power cord should be  plugged into a wall outlet that is accessible     4 Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    Preface    Keypad usage    The keypad and its usage are explained below     Item       Function    MODE key   e This button is used to switch between different system modes  Standby mode   Ready mode or in Configuration mode    e From Standby  press twice    to go to Ready     e From Ready  press 
20. once    to go to Standby    LEFT or RIGHT key   These buttons are used to navigate in the user interface software  They are also used   to change configuration or set point values    VALIDATE key   This button is used to confirm a change or an action required by the water system  It   is also used to save any changes made in configuration    HELP INDICATOR icon   e There are up to 3 of these icons on the display depending upon the software mode   These indicators are here to tell the user which keypad button is available and  active    See the examples below    3 help indicators    e Press on     Mode key  to switch operating mode    e Press on   r to navigate in the software branch    e Press on    Validate key  to configure ECO mode    2 help indicators       erg       E mans   e Press on     Mode key  to switch operating mode      IL e Press on ri to navigate in the software branch     1 help indicator    E  0000 e Press on  amp   Mode key  to switch operating mode     Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system 5    Table of contents       Table of contents    A aaa aa aAa aaa inaa ia 11  Hems Checks To ae de ee nn ne de 12  Millitrack   ug 13   SYSTEM a a a A 15  DIS AV ICON mai Bee 16  SO NAT NOR Re ee ee ee dao 17  OPERATING PRINCI PIG and Stasi    E 18  Maintenance information Minnie nuls 19  Configure system parameters Fd tE nia 20  View operation parameters sie 22  Software naviga ton Map anne ee nono nina 23   Consumables repla
21. ool  unscrew 2 Remove the plug and insert 3 Screw the plug back  make  the sanitation port cap  the tablet in the port  sure the o ring Is in place   Note   do not use the tool to screw  the plug   the plug may be  screwed too tightly        Starting pH cleaning    E  E col E    PH               1 In Standby  press     2 Press on right arrow 3 Press   for 1 second to     Jt    to reach PH  start pH cleaning   Be po    a D          4 The cleaning lasts 5 Once the cleaning is  82 minutes  finished  press    to put the    system in Standby     FO xX  Ne S    6 Unscrew the plug and 7 Screw the plug back and  remove the empty pouch put the system in Tank  from the cleaning port  filling by pressing twice        Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system 31    Other functions       Other functions    Saving display energy   ECO mode    When this function is activated  the ECO mode is used to save energy when the display is  not used  It shuts down the system s display backlight after a 15 min period of non use     The ECO mode is disabled by pressing a keypad button or when a warning message is  displayed by the system  error code or warning symbol      Configuring ECO mode    Po    cio   Esses             1 Put the system in Standby 2 Press   once again  3 You are in configuration  by pressing     mode      a Se Es y  Be eco   YES      4 Press on right arrow 5 Press   to change the 6 NO  Press   to confirm     J    until you reach setting bet
22. ore investigation is required    e Red color display  Er 02 and EN   e Ihe system has detected a dysfunction when operating in normal  conditions  Refer to section Error codes at page 38 or contact  Millipore        e Red color display and L   the Progard pack has been removed   e Tool icon indicates maintenance     d           d  a       Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system 17    System    Operating principle and status    The RiOs Essential is a water system designed to produce type III water  The Elix Essential is  a water system designed to produce type Il water  This water can be stored in a reservoir  if    installed     As a summary  the Elix Essential purifies tap water using the Progard Pack and Reverse  Osmosis followed by Electrical Deionization   EDI    There is no EDI in a RiOs Essential    system     Understanding the terminology of operating status     TANK FILLING    FLUSH    RINSING    SANITIZATION    CLEANING    The tank is being filled with EDI or RO water  A sensor starts and stops  this mode     A periodic flush of the RO portion of the system is done  This refreshes  the water in this part of the system if they are not being used to produce  water     A sensor has determined that the RO portion needs to rinse itself before  sending water to the EDI device     There are different types of sanitization that can be done  See the  maintenance section in this document for more information     An acid or base cleani
23. tart a Progard flush  press   for 1 second   e Wait 15 minutes for the Progard flush to finish     Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system 27    Sanitization and cleaning       Sanitization and cleaning    Sanitizing RO membranes with chlorine    e    chlorine tablet is periodically used to reduce or remove a layer of bio film on the feed  water side of the RO membrane     e When the system shows the yellow alert E icon   put the system in    Standby by pressing     e QA   m       1 Using the tool  unscrew the 2 Remove the plug and insert 3 Screw the plug back  make  sanitation port cap  the tablet in the port  sure the o ring is in place     Use proper safety  equipment     Starting CL2 sanitization    S oa   Ba ge B ogo    1  Press   for 1 second to 2  The sanitization lasts 3 System goes in Ready or  start CL2 sanitization  19 min  in Tank filling        30 Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    Sanitization and cleaning  Cleaning RO membranes with acid base  pH     e It may become necessary to remove any built up layer of mineral scale or organic  material  This is done with a Merck Millipore pH Cleaner  Contact Merck Millipore for  more information about their use     e To start the cleaning  make sure the system is in Standby or put the system in Standby by  pressing       A  aa      IN A r A F  Tess d      Lo  SN      F L  A  r L _      p          W Ze     a    o       1 Using the t
24. ween YES or    and exit     34 Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system    Other functions    System is not used for a long time   Lab Closed    You can use the Lab Closed function whenever the system is not be used for a long time   In this mode  water quality is maintained by periodic automatic flushing and rinsing    Do not power off the system more than 7 days  The system time and date  can be lost as a result  If the system is shut off for a long period of time   contact your service representative     1 Insert one end of the tubing in the ball  valve  And the other end to drain     2 Open the ball valve        Configuring Lab Closed mode    ge 1 e    1 Put the system in 2 Press on right arrow 3 Press   to activate the  Standby      Hr  until you reach  Lab Closed mode     au   Moose          Exiting Lab Closed Mode    1  Close the ball valve     SODA   E      H ISG    2 From lab closed mode  3 The system goes in Tank  press     for 1 second  filling     Elix   Essential 3  5  10  15  UV  system   RiOs    Essential 5  8  16  24 system 35    Error messages       Error messages    Error codes    An error code is always displayed with and can be displayed in two different ways     Yellow alert error  Red alarm error     The list of error codes is presented below     Code Meaning What to do    Er 01 Tap feed water conductivity  gt  set point Contact your service representative   Er 02 Feed water temperature  gt  set point See next pag
    