Home

USER MANUAL

image

Contents

1. COLOUR STORM RGB Order code LEDJ166 USER MANUAL Colour Storm RGB Safety WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty Colour Storm RGB Safety IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution e Never remove warning or informative labels from the equipment Do not open the equipment and do not modify
2. Colour Storm RGB Built in Programme Chart 14 Built in programme chart BLA Blackout R Red RG Yellow G Green STATIC COLOR GB Cyan B Blue BR Purple RGB White BLACKOUT RGB Flash speed adjustable 00 99 Speed 00 99 Flash 00 99 Speed 8 Flash adjustable Speed 00 99 Flash 00 99 Speed 8 Flash adjustable Speed 00 99 Flash 00 99 Speed 8 Flash adjustable Speed 00 99 Flash 00 99 Speed 8 Flash adjustable Seven colour chase forward Speed 00 99 Flash 00 99 Speed 8 Flash adjustable Seven colour chase forward amp reverse Speed 00 99 Flash 00 99 Speed 8 Flash adjustable Seven colour fade chase in relay pattern forward Speed 00 99 Flash 00 99 Speed 8 Flash adjustable Seven colour fade chase in relay pattern forward amp Speed 00 99 Flash 00 99 reverse Speed amp Flash adjustable Speed 00 99 Flash 00 99 Speed amp Flash adjustable Seven colour chase from centre to sides Speed 00 99 Flash 00 99 Speed amp Flash adjustable FLOW 8 Two colour chase forward Speed 00 99 Flash 00 99 Speed amp Flash adjustable 1 BLA RGB 2 BLA RGB Blackout Red Yellow Green Cyan Blue Purple White Two colour chase forward amp reverse FLOW 9 Speed amp Flash adjustable Speed00 99 Flash 00 99 BLA Blackout R Red RG Yellow G Green 1 BLA RGB 2 BLA RGB GB Cyan B Blue BR Purple RGB White Colour Storm RGB DMX Programme Charts 6 channel mode DMX chart 11 21 Master dimmer Flash All Red All Green All Blue 0 255 0 255 LEDs
3. 0 255 16 CH17 CH18 CH19 20 CH21 22 CH23 CH24 CH25 CH26 CH27 Colour Storm RGB DMX Set up DMX 512 e DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation Colour Storm RGB be controlled via DMX 512 protocol The DMX address is set on the back of the unit
4. Your unit and your DMX controller require a standard 3 pin XLR connector for data input output figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers Please quote CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split Colour Storm RGB DMX Set up Notice sure to follow figures 2 amp 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out 3 pin XLR DMX 512 in 3 pin XLR XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground Pin 2 Negative FIGURE 3 FIGURE 2 Special Note Line termination e When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems O and interferance it is always advisable to connect a DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 pin XLR connectors for data transmissio
5. 1D controller LEDJ123 please ensure that the Colour Storm RGB has been set into SLAVE MODE and connect the controller to the 3 pin XLR socket on the rear of the unit The HBR 1D can be used in conjunction with the MB 2 Footswitch LEDJ124 by plugging the 5 pin XLR from the MB 2 into the HBR 1D controller Note please follow the user manuals supplied with the optional MB 2 and HBR 1D controllers for details of various operation modes Colour Storm RGB Operation Modes Operation modes Sound Active mode To activate the unit in sound active mode press the MODE button to show SOUND MODE on the LCD screen Now press the SET UP button to select the desired sensitivity level by using the UP and DOWN buttons Press the SET UP button again to select the freguency level and adjust by using the UP and DOWN buttons SENS 00 31 00 low 31 high FAN 01 99 01 low 99 high Auto run mode To activate the unit in auto run mode press the MODE button to show AUTO RUN on the LCD screen Now press the SET UP button to select the desired freguency level by using the UP and DOWN buttons FAN 01 99 01 low 99 high Note In this mode it will run 13 built in programmes in a continious loop Slave mode To activate the unit in slave mode first you must link multiple units together and press the MODE button to show SLAVE
6. LEDs LEDs 0 255 0 255 0 255 22 32 Red Flash 0 255 33 43 Yellow Flash 0 255 44 54 Green iFlasn 0 255 55 65 Cyan Flash 0 255 66 76 Blue 7 Flash 0 255 77 7 Purple Flash 0 52 88 98 White Flash 0 255 99 109 Dream Speed 0 255 Flash 0 255 110 120 Meteor Speed 0 255 Flash 0 255 7 121 131 Fade Speed 0 255 Flash 25 132 142 Change Speed 0 255 Flash 25 143 153 Flow 1 Speed 0 255 Flash 0 255 154 164 Flow 2 Speed 0 255 Flash 0 255 165 175 Flow 3 Speed 0 255 Flash 25 176 186 Flow 4 Speed 0 255 Flash 0 255 187 197 Flow5 Speed 0 255 Flash 0 255 A S iil select fee eee MIOS IO ee ll s ld active 9 channel mode DMX Chart Master Flash dimmer 0 255 R1 G1 B1 R2 G2 B2 0 255 Note For 9 15 and 27 channel modes please follow the 6 channel DMX chart for channels 1 2 and 3 Colour Storm RGB DMX Programme Charts Note For 9 15 and 27 channel modes please follow the 6 channel DMX chart for channels 1 2 and 3 15 channel mode DMX chart Master Dimmer Flash 0 255 0 255 24 channel mode DMX chart EEE E CH16 CH17 CH18 CH19 CH20 CH21 CH22 CH23 CH24 27 channel mode DMX chart 11 21 Master Flash Dimmer 0 255
7. MODE on the LCD screen Now on the master unit press the MODE button to select the desired mode and the slave units will now run in seguence with the master unit Built in programmes To activate the units built in programmes press the MODE button to show 01 STATIC on the LCD screen Press the SET UP button to choose between the 14 built in programmes by using the UP and DOWN buttons Now press the SET UP button to select the desired speed and adjust by using the UP and DOWN buttons Press the SET UP button once more to select the desired flash value and adjust by using the UP and DOWN buttons Speed values 00 99 00 slow 99 fast Flash values 00 99 00 slow 99 fast For the 14 built in programmes please see page 5 DMX mode To activate the unit in DMX mode press the MODE button to show DMX MODE on the LCD screen Press the SET UP button and select the desired DMX address setting by using the UP and DOWN buttons Then to select one of the 4 DMX modes 6 9 15 24 and 27 channel press the SET UP button again to choose the desired DMX mode by using the UP and DOWN buttons For the 6 9 15 24 and 27 channel DMX address information please see pages 6 8 7 NOTE Once the desired settings have been selected in each of the above modes ALWAYS confirm the settings by pressing the SET UP button 4
8. chase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property Colour Storm RGB Introduction Introduction Features e DMX channels 6 9 15 24 27 selectable e LEDs 24 x 5W LEDs R 8 8 8 e Sound active auto run master slave and DMX modes e Each LED is individually addressable 400Hz flicker free LEDs Powercon in out sockets 3 Pin XLR in out sockets e 4 push button menu with LCD display e 0 100 dimming e Beam angle 30 degrees Overview Hanging Power bracket out power LCD Display 7 1 E o E EX COLOUR STORM i 5 DMX 2 2 www prolight co uk DON DMX Mode Enter button button 2 button Down Safety Safety eye eye Setup Operating Instructions The Colour Storm RGB is a DMX 512 controllable unit made up of high efficiency and Ultra Bright RGB LEDs and will operate in auto run master slave sound activated or DMX control modes HBR 1D Operation optional To operate the Colour Strom RGB via the optional LEDJ HBR
9. n in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The chart below details the correct cable conversion 5 Pin ALR socket 1 sereen A 3 Pin XLR socket Pin 2 Signal 1 GND sereen Pin 3 Signal 2 Pin 2 Signal in 4 Pin 3 Signal Pin 5 N C 3 Pin ALR socket Pin 1 GNI screen Pin 2 Signal 2 3 Signal Colour Storm RGB Technical Specifications Technical Specifications Weight 8 Dimensions ss AAA 1055mm A jj oe 165mm a 176mm eo 7 3Kgs Power A A 240V 50hz e Power 2 44 4 120W e Fuse AMI F2A Control 8 Programming Data Locking 3 pin XLR male socket Data DUT RR Locking 3 pin XLR female socket Ao A DMX 512 USITT e DMX 6 9 15 24 and 27 10
10. the equipment e Do not connect this equipment to a dimmer pack e Do not switch the equipment on and off in short intervals as this will reduce the system s life e Only use the equipment indoors Do not expose to flammable sources liquids or gases e Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 220 240 e Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature e If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service e Only use fuses of same type and rating Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS e WARRANTY One year from date of pur

Download Pdf Manuals

image

Related Search

Related Contents

King Canada KC-3108C User's Manual  TuneUp Utilities - 2013 User's Manual  OPERATORS MANUAL - Sagene samfunnshus  ADDON T3 - Audio Pro  ESU-21 - サンケン電気  Fujitsu ESPRIMO E5645  Fujitsu HS S2000NC  RITCHEY User Manual Introduction Before Your First Ride  Phonix IP5CPW mobile phone case  Two Line FWP w_Wifi AP User`s Guide  