1. User s DX Advanced Manual Daqstation DX1000 DX1000N DX2000 Multi Batch Function BT2 User s Manual vigilantplant YOKOGAWA IM 04L41B01 03E Yokogawa Electric Corporation 2nd Edition Notes Trademarks Revisions 2nd Edition March 2010 YK Thank you for purchasing the Daqstation DX1000 DX1000N or DX2000 hereafter referred to as the DX This manual describes the operating procedure for the DX Multi Batch function BT2 option Please use this manual in conjunction with the DX1000 DX1000N User s Manual IM04L41B01 01E or the DX2000 User s Manual IM04L42B01 01E The contents of this manual are subject to change without prior notice as a result of continuing improvements to the instrument s performance and functions Every effort has been made in the preparation of this manual to ensure the accuracy of its contents However should you have any questions or find any errors please contact your nearest YOKOGAWA dealer Copying or reproducing all or any part of the contents of this manual without the permission of YOKOGAWA is strictly prohibited The TCP IP software of this product and the documents concerning it have been developed created by YOKOGAWA based on the BSD Networking Software Release 1 that has been licensed from the Regents of the University of California vigilantplant DAQSTATION Daqstation and DXAdvanced are registered trademarks of Yokogawa Electric Corporation Microso
2. also display the Multi batch tab s setup screen by selecting the Menu tab gt Group set Trip line gt Trip line g EM G aLL Batch S First Batch Group Ei Last Batch Group 1 Display Group No 1 Trip line Position Color Width 1 on sex B Red 2 dot 2 o 50 WM Green 2 dot 3 off 4 off Input 1 zil IM 04L41B01 03E 2 2 Setting the Multi Batch Function Settings for the DX2000 Press MENU to switch to setting mode and select the Multi batch tab gt Group set Trip line Youcan also display the Multi batch tab s setup screen by selecting the Menu tab Group set Trip line BATCH OVERVIEW Se 2008 12 09 18 15 19 Wwe Beene B Group set Trip line First Batch Group No Last Batch Group No 1 Display Group No 1 r Set Display Group On Off o Group nane GROUP 1 CH set 001 002 883 884 685 606 887 888 489 618 r Trip line Position Color Line width 1 On 58 2 L Red 2 dot 2 On 58 2 L Green 2 dot 3 Off 4 Off Input CENE File Header and Data File Names Press MENU to switch to setting mode and select the Multi batch tab gt File header File name For the DX2000 select the Multi batch tab File header Data file name You can also display the Multi batch tab s setup screen by selecting the Menu tab Data save gt File header File name DECR ALL BaTcH 9 First Batch Group Last Batch Group 1 File header Characters Data file n
3. data files Configuration Example File Name for a Display Data File A00123_AAAAA081201_173524 DAD Batch group 1 The sequence number is A00123_ The specified string is B00123 AAAAA DAD Batch group 2 The sequence number is B00123 The specified string is C00123 SAMPLE 1 DAD Batch group 3 The sequence number is C00123_ The batch name is SAMPLE 1 Operations You Can Perform on Each Batch Writing Messages and Writing Free Messages You can write different messages for each batch group For operating instructions see section 3 6 Computation Reset M1 and PM1 Options You can reset the computed result on the computation channels in use for each batch group For operating instructions see section 3 2 Text Field Display You can display text fields for each batch group For operating instructions see section 3 8 4 Panel Display Only for the DX2000 You can register and display four screens for each batch group For operating instructions see section 4 10 in the DX2000 User s Manual Saving Display Data and Event Data For operating instructions see section 3 1 Changes to Features The following standard features differ between a DX with the Multi Batch function and a DX without it Feature Description amp imer You can use 12 timers Match time timer You can use 12 match time timers Switching the trend interval When the Multi Batch function is enabled
4. for the display groups that you want to display Set Display Group Group name Set the group name Up to 16 characters Alal 1 Set Display Group CH set Set the channel numbers for measurement computation M1 and PM1 options and external input on DX2000s with the MC1 option channels Model Maximum Number of Channels DX1000 6 Enter the channel number using two or three digits Separate each channel with a period To specify a range of consecutive channel numbers use a hyphen Example To assign channels 1 and 5 to 8 enter 001 005 008 2 4 IM 04L41B01 03E 2 2 Setting the Multi Batch Function Trip line gt 1 2 3 4 Select On for the trip lines that you want to display Trip line gt Position Set the position in the range of 0 to 100 of the display width Trip line gt Color The default colors are red green blue and yellow If want to change a color you can select from 24 available colors Trip line gt Width Set the line width of the trip line in dots 1 to 3 File header gt Characters Enter a header comment to write into data files The file header is displayed on the batch overview screen s batch identification bars the status display section for batch single mode only for the DX2000 and the title bar for the start and stop recording screens Up to 50 characters Alal 1 Data file name gt Structure Sets the s
5. interval Save destination directory Manual sampled data file Report file a Batch Group 1 Report start or stop Math start or stop Snapshot data file Display groups Start recording E 99 Data file display data or event data Writing messages Computation reset File name Batch number and lot number File header Batch text Batch comment 3 Stop recording TOOL Measured data Batch Group 2 Display groups Start recording ES N Data file display data or event data Writing messages Computation reset File name Batch number and lot number File header Batch text Batch comment OOO Stop recording Measured data represents user actions IM 04L41B01 03E 1 1 Recording and Saving Data Recording and Saving Starting and Stopping Recording Memory Sampling You can start and stop recording for each batch group individually Or you can start and stop recording across all batch groups simultaneously Feature Operation Example Recording Start and stop batch groups individually Start Stop Batch Group 1 Yoy Start Stop Batch Group 2 e Start Stop Batch Group 3 yY yY Simultaneous start and stop Start Simultaneous start Y Tm Stop Simultaneous stop d Report Start Stop Computation Starting computatio
6. name details are the same as with a DX without the Multi Batch function Manual sampled The string used in the file name is the one specified for data batch group 1 Other file name details are the same as with Snapshot data a DX without the Multi Batch function Report data Batch One character in the file name sequence number is Event data allocated to identify the batch group A separate batch name for each batch group is used Other file name details are the same as with a DX without the Multi Batch function Manual sampled File name details are the same as with a DX without the data Multi Batch function Snapshot data Report data 1 6 IM 04L41B01 03E 1 1 Recording and Saving Data File name sequence number for display data and event data ltem Description File name 1 character batch group identifier 5 digit number 1 character delimiter sequence Batch group JA B C D E F G H J K L or M Ais used for batch group 1 number identifier B is used for batch group 2 M is used for batch group 12 Number A number that indicates the file s order of occurrence The number ranges from 00001 to 99999 After 99999 the number returns to 00000 Delimiter The delimiter is the same as with a DX without the Multi Batch function For details on the delimiter used see section 1 4 in the User s Manual File name examples The following are file name examples for display
7. on DX2000s with the MC1 option Trend interval Event data The following settings cannot be changed while their applicable batch group is recording Batch text Display group Trip line For information about changing settings during recording on DXs with the AS1 advanced security option see section 6 4 in the User s Manual IM 04L41B01 03E 2 1 TM HU 2 2 Setting the Multi Batch Function This section explains the specialized settings for the Multi Batch function For details on other settings see the User s Manual Setup Screen Multi Batch Function Press MENU to switch to setting mode hold down FUNC for 3 s to switch to basic setting mode and select the Environment tab gt Batch Basic Setting Node Batch On Off Lot No digit 6 Auto increment On Batch operation qty 4 On Off Mul ti Group Set Trip Line Settings for the DX1000 Press MENU to switch to setting mode and select the Multi batch tab gt Group set Trip line gt Group set You can also display the Multi batch tab s setup screen by selecting the Menu tab gt Group set Trip line gt Group set JEUNE ALL BATCH K First Batch Group Ei Last Batch Group 1 Display Group No 1 Set Display Group On Off On Group name GROUP 1 CH set fl 002 003 004 005 006 Input 1 ET Press MENU to switch to setting mode and select the Multi batch tab gt Group set Trip line gt Trip line You can
8. 2000 User s Manual INFORMATION JALARM Information regarding the Sections 1 3 and 4 6 in the SUMMARY alarm that occurred in the User s Manual target batch group Information regarding the Sections 1 3 and 4 7 in the messages written for the User s Manual target batch group Information regarding data Sections 1 3 and 4 8 in the for the target batch group Status Display Section With the following exception items shown in the status display section are the same as with a DX without the Multi Batch function For details on the status display section see section 1 3 in the User s Manual DX1000 m Batch identification number 1 represents batch group 1 The display group name and batch name are displayed alternately DX2000 ERES SEA S Dio TF n Batch identification number and file header BATCHI 1 2008 12 09 82 44 41 The display group name and batch name are displayed alternately IM 04L41B01 03E Chapter2 Settings 2 1 Settings for the Multi Batch Function Specialized Settings for the Multi Batch Function Enabling the Multi Batch Function First enable the Multi Batch function The measured data in internal memory is cleared when you enable or disable the Multi Batch function However updating the number of batches used with the Multi Batch function does not clear the measured data in internal memory Settings for Each Batch Group The settings you can change for each ba
9. 3 14 IM 04L41B01 03E 3 7 Using the Favorite Key For details on the setup screen settings and operating procedures see section 5 15 in the DX1000 DX1000N User s Manual and section 5 16 in the DX2000 User s Manual When You Set Action to Favorite e You can register displays from both batch overview mode and batch single mode to the favorite key e f you register the historical trend s alarm summary or message summary displays to the favorite key register them so that they come after the historical trend display If any other screen is registered before them the DX shows the historical trend display instead of the alarm summary or message summary displays f due to changes to the DX s settings after you register a display to the favorite key the batch group number or display group number registered no longer exists the DX shows the display belonging to the smallest available display group number of the smallest available batch group number When You Set Action to History Batch overview Does not switch to the historical trend display with the currently displayed mode data Note that the DX does not display an error message Batch single mode Switches to the historical trend display for the currently displayed batch group IM 04L41B01 03E suonejedo B 3 8 Displaying Text Field Settings Procedure Procedure in Batch Overview Mode 1 In operation mode press FUNC The FUNC key menu appears Pre
10. For operating instructions see section 3 3 CUSTOM DISPLAY For operating instructions see IM04L41B01 04E OVERVIEW Displays the status of all channels For operating instructions see section 4 4 in the User s Manual ANNUNCIATOR For operating instructions see section 3 12 in the User s Manual INFORMATION The following items can be selected from the submenu MODBUS CLIENT MODBUS MASTER RELAY REPORT DATA COLUMN BAR and EVENT SWITCH For operating instructions see section 4 5 in the User s Manual Also see section 4 10 in the DX1000 DX1000N User s Manual and section 4 11 in the DX2000 User s Manual You can also select the following methods to save data from the information submenu M SAMPLE SAVE REPORT SAVE and ALL SAVE For operating instructions see section 4 8 in the User s Manual LOG The following logs can be selected from the submenu and displayed Login log error log communication log FTP log e mail log web log SNTP log DHCP log modbus status log operation log and change settings log 1 Only on DXs without the AS1 advanced security option 2 Only on DXs with the AS1 advanced security option For display information see section 4 9 in the User s Manual IM 04L41B01 03E 3 9 suonejedo B 3 4 Using Batch Overview Mode Loading Display and Event Data Even when in batch overview mode you can use the following procedure to load display or event data and display the correspond
11. IGITAL and BAR For operating instructions see section 4 2 in the User s Manual CUSTOM DISPLAY For operating instructions see M04L41B01 04E OVERVIEW Displays the status of all channels registered to the batch group For operating instructions see section 4 4 in the User s Manual ALARM SUMMARY MESSAGE SUMMARY and MEMORY SUMMARY For operating instructions see sections 4 6 4 7 and 4 8 in the User s Manual 4 PANEL For operating instructions see section 4 10 in the DX2000 User s Manual Loading Display and Event Data You can use the following procedure to load display or event data and display the corresponding historical trend Press MENU to switch to setting mode and select the File tab gt Load display data or Load event data gt press the CF or USB soft key gt select the file and press DISP ENTER Take note of the following points regarding loading of data You can load any batch group s data Whether you load the data for the currently displayed batch group or another batch group the currently displayed batch group does not change IM 04L41B01 03E 3 11 3 5 Using Batch Single Mode Using the FUNC Key You can use the FUNC key for the following operations For operating procedures see the reference for each respective operation Entries marked with a T function the same as in batch overview mode Operation Name T Alarm ACK Executes alarm acknowledgement Section 3 8 in the User s Manual f
12. R Recording starts for the selected batch group The internal memory icon in the status display section changes from the icon that indicates that memory sampling is stopped to the icon that indicates that memory sampling has started For details on starting reports and computations see section 1 1 IM 04L41B01 03E 3 3 3 1 Starting Stopping Recording and Saving Data Stopping Recording from Batch Overview Mode 1 Press STOP The batch group selection window appears 2 Press the numeric soft keys that represent the batch groups you want to stop recording Batch name No SAHPLE B 2124 881246 Comment Green Recording White or Black Not recording The batch group number All All batch groups currently recording The stop recording screen appears When You Select a Single Batch Group 3 Use the arrow keys to move the cursor to Yes and press DISP ENTER Recording stops for the selected batch group When all batch groups stop recording the report function M1 and PM1 options also stops NE FETTE Batch name No SAMPLE B 2124 601246 j Do you want to stop data storage DISP E 58min DISP Ihour When You Select All 3 Use the arrow keys to move the cursor to Yes and press DISP ENTER Recording stops for all batch groups The report function M1 and PM1 options also stops TUE GA ace earch OER 1 BATCH 3 BATCH 3333 PRODUCT A 1827 9808 Batch All _ Do y
13. R EE ia 1 3 Operations You Can Perform on Each Batch sssssssssssssseeeeeenerenes 1 7 Changes to Features innere ete tte ite hee dk LU eee A Nan tiec eos EX e ERR ERES 1 7 12 DISDIAY PE QM 1 8 Batch Overview Mode 75 tei cite tae ates Haec so e EON LY Ree ERE ELM EE EER EEES 1 8 Batch Single MOG Gs sscccecszcec scees 1 10 Settings 2 1 Settings for the Multi Batch FUNCION sssrinin aaas Specialized Settings for the Multi Batch Function General Settings Other Than the Specialized Settings for the Multi Batch Function 2 1 PRECAULIONS korsire c E 2 1 2 2 Setting the Multi Batch FUnclon aiccori ruentem ito cher draco true iE rentem iet a un pegn 2 2 2 3 Using the Event Action Function icai ee cere eee e Aliant 2 6 Setup Example Starting and Stopping the Recording of Batch Group 2 2 6 Operations 3 1 Starting Stopping Recording and Saving Data ssssse em 3 1 3 2 Starting Stopping and Resetting Computations M1 and PM1 Options 3 6 3 3 Switching Between Batch Overview Mode and Batch Single Mode 3 8 3 4 Using Batch Overview Mode eret rete e Eee aere Pu HE Re e Edo ek Res ERES 3 9 3 5 Using Batch Single Mode erect teer etit deti title aa decirte d oe 3 11 3 6
14. Writing MESSAGES ss e 3 13 3 7 Using the Favorite Key iiic teneo eoe le Adina aan 3 15 3 9 Displaying Text Field Settings niri ttt ta remit eh dessa a 3 16 3 9 Changing the FUNC Key Menu and the Display Selection Menu ssess 3 17 3 10 Saving to USB Flash Memory USB1 Option ssseem e 3 18 IM 04L41B01 03E Chapter 1 Description of the Multi Batch Function 1 4 Recording and Saving Data Outline The Multi Batch function allows you to record and save the measured data from multiple batches separately per batch You can also apply the Multi Batch function to multiple consecutive processes The diagram on the following page gives a general overview of the Multi Batch function Number of Batches The table below shows the number of batches supported by the DX Each batch is known as a batch group Model Number of Batches DX1000 DX2000 2to 12 Recordable Channels On the trend digital and bar graph displays channel data is displayed in preset groups These groups are referred to as display groups The number of display groups that can be assigned to a batch group and the number of channels that can be assigned to a display group are indicated below The same display groups are used for the trend digital and bar graph displays For each batch group the measured data is displayed per display group The DX records the data from the measurement ch
15. ame Structure Date Identified strings Input 1 Z Batch Text Press MENU to switch to setting mode and select the Multi batch tab Batch text You can also display the Multi batch tab s setup screen by selecting the Menu tab Data save gt Batch text VERVIEW SA ca 2 01 07 09 05 Ye ALL BATCH S First Batch Groupi Last Batch Group 1 Text field number 1 Title of field Characters Input 1 zl IM 04L41B01 03E Tus gt 2 2 Setting the Multi Batch Function Batch On Off Select Multi Batch Laer er ER RTT Enables the single batch feature For details see section 6 3 in the User s Manual Off Disables the batch feature MultiBatch Enables the Multi Batch function Batch gt Lot No digit Set the lot number digits to 4 6 or 8 Select Off to disable lot numbers Baten gt Auto increment Automatically sets the lot number of the next measurement to the current lot number 1 Turns auto increment off Batch gt Batch operation qty Specify the number of batches to use The number of batches specified with this setting corresponds to the number of batch groups you can use Model Number of Batches Supported DX1000 DX2000 2to 12 First Batch Group and Last Batch Group Select the target batch groups Display Group No Select the target display group number Model Display Group Number DX1000 DX2000 1to 12 Set Display Group On Off Select On
16. and comment Section 6 3 in the User s Manual for the selected batch group Displays the text field for the batch Section 3 8 in this manual group that you select Switches to builder screen mode IM04L41B01 04E T Favorite Registers the current display asa Section 3 7 in this manual registration favorite Registers the 4 panel configuration Section 4 10 in the DX2000 and changes the 4 panel display User s Manual names T Standard display Registers the current display as Section 5 14 DX1000 the standard DX display Section 5 15 DX2000 in the User s Manual T SNTP Synchronizes the DX s time with Section 1 8 in the Communication an SNTP server Manual T E Mail start stop Starts or stops e mail transmission Section 1 4 in the Communication Manual T E Mail test Confirms sending of e mail and the Section 1 4 in the Communication details of the transmission Manual the DX and the FTP server Manual Only for the DX2000 3 12 IM 04L41B01 03E 3 6 Writing Messages This procedure shows how to write messages for batch groups Setup Screen How to Write Messages Press MENU to switch to setting mode hold down FUNC for 3 s to switch to basic setting mode and select the Environment tab gt View Message Basic Setting Node suonejedo B View Trend type rv Partial Off Trend rate switching Off Hessage Write group Power fail message Off Change
17. and precautions that can be taken to prevent such occurrences Calls attentions to actions or conditions that could cause light injury to the user or damage to the instrument or user s data and precautions that can be taken to prevent such occurrences Calls attention to information that is important for proper operation of the instrument Denotes key or character strings that appear on the screen Example Volt Indicates character types that can be used A Uppercase alphabet la lowercase alphabet fl symbols 1 numbers Carry out the procedure according to the step numbers All procedures are written with inexperienced users in mind depending on the operation not all steps need to be taken Explanation gives information such as limitations related the procedure Indicates the setup screen and explains the settings A detailed description of the function is not provided in this section For details on the function see chapter 1 IM 04L41B01 03E Applicable Recorders The models outlined in this section can be equipped with the Multi Batch function In this manual the terms DX1000 and DX2000 refer to the following models DX1000 DX1006 DX1012 DX1006N and DX1012N DX2000 DX2010 DX2020 DX2030 DX2040 and DX2048 What This Manual Explains This manual explains the DX Multi Batch function For details on the DX s standard operations see the DX1000 DX1000N User s M
18. annels computation channels or external input channels only available on the DX2000 that are registered to the display groupe a a asinge ispay Group o Groups a Single Display Group px1o00 e A4 Je e The conditions for recording display or event data scan interval sampling interval and data type apply to all batch groups Likewise the conditions for saving data files file save interval and save destination directory apply to all batch groups You can start and stop recording for each batch group individually Other actions such as writing messages and resetting the values calculated on computation channels M1 and PM1 options can also be carried out for each batch group individually The computation and report functions M1 and PM1 options each start and stop simultaneously across all batch groups Display data and event data are saved per batch group Batch numbers lot numbers file headers batch text batch comments and other batch information are saved to files along with measured data Manual sampled data report data and snapshot data are all saved to their own individual files with no distinction between batch groups IM 04L41B01 03E 1 1 uonoung uojeg nini eu jo uonduoseg E 1 1 Recording and Saving Data Multi Batch Function Conditions for Recording and Saving Display Data and Event Data Scan interval Data record Display data or Event data Sampling interval File save
19. anual IM04L41B01 01E or the DX2000 User s Manual IM04L42B01 01E For details on the DX s communication functions see the DX1000 DX1000N DX2000 Communication Interface User s Manual IMO4L41B01 17E This manual explains how to use the Multi Batch function on the DX1000 For the cases where the usage differs for the DX2000 this manual also explains how to use the Multi Batch function on the DX2000 The following terms are used for references to other manuals User s Manual Refers to DX1000 DX1000N User s Manual IM04L41B01 01E or DX2000 User s Manual IM04L42B01 01E Operation Guide Refers to DX Operation Guide IM04L41B01 02E or IM04L42B01 02E Communication Manual Refers to DX Communication Interface User s Manual IM04L41B01 17E Advanced Security Manual Refers to DX Advanced Security Function AS1 User s Manual IM04L41B01 05EN IM 04L41B01 03E Contents Chapter 1 Chapter 2 Chapter 3 Index Conventions Used in This Manual sssssssssssssssseseeeeener enne tnnt rt nnne nens ii Applicable Recorders iod eto eee ene e fein cie ee del ele odes iii What This Mariual Explains iini teinte eoe ae ae aaa o aa aaa a rara iia iii Description of the Multi Batch Function 14 Recording and Saving Data ceret Seins rettet notte epe seats tp db epi va rear risposta ested 1 1 Gu 1 1 ReCOrding ANG SAVING ER pnra aE E Ea EEE a
20. art stop oe E MalliteSta ui eie or m b ated o ei dere Edge SWIIChi rone ee Favorite registration seesssssssss 3 10 3 12 Free message iei ce edem Cose aH ERAI R E 3 12 FTP test A Key lOCK ce rtt et sem 3 10 3 12 Locked ACK xin ettet rrr iie petes ens 3 10 3 12 logout 3 10 3 12 Manual sample 3 10 3 12 Match timer reset 9 10 3 12 Matti ACK iuo tct oci tiet tied been 3 10 3 12 Matli Start StOD ciui edere tie gerant te ced n epe theta 3 10 Media eject Up M S Network IMO siesatini iee ees 3 10 Password Changes reiecta iz 3 10 3 12 Save display data sse 3 12 Save event data i um Snapshot auc e e ee e reda hc Standard display eet peret 3 10 3 12 System info uni Hm Timer reset FUNG key menus changing 2 erre erit 3 17 G QFOUP NAME Lectern eos teret et epica ences 2 4 I identified SITIGS S eere rode eri AAEE 2 5 AS lot iurmber digits e petto i aena 2 4 M mian al sampled data titre ect tane tos manual sampled data recording Mice RITTER memory sampling starting and stopping 1 3 Messages Writing reete mode switching MUDAT Mia arreter eere VES EEEE 2 4 N MOLES A TA TE E i IM 04L41B01 03E Index 1 2 o O x Index i recordable charinels er err rr
21. batch group Red Atleast one alarm is activated Green No alarms are activated Blinks the same way as the alarm icon on the status display section blinks Batch number Lot number Data type Recording progress Time remaining before data is automatically saved Display Layout Model Number of Batch Groups Display Layout Vertical x Horizontal x 3 2x3 Batch groups are assigned to windows starting with the left column Batch groups are assigned in ascending order by their group number The following example shows the case for six batch groups Batch group number IM 04L41B01 03E 1 9 uonounj uojeg nini eu jo uonduoseg E 1 2 Display Batch Single Mode This section outlines the information displayed in batch single mode Name Display Details Status display section See the following figure Section 1 3 in the User s Manual TREND The target batch group s trend Sections 1 3 and 4 2 in the display User s Manual TREND HISTORY The target batch group s Sections 1 3 and 4 3 in the historical trend display User s Manual The target batch group s Sections 1 3 and 4 2 in the digital display User s Manual The target batch group s bar Sections 1 3 and 4 2 in the graph display User s Manual OVERVIEW Shows the status of all Sections 1 3 and 4 4 in the channels for the target batch User s Manual group 4 PANEL 4 Panel display for the target Sections 1 3 and 4 10 in the batch group DX
22. below the remote control function R1 and PM1 options is used to start and stop the recording of batch group 2 according to the input received by remote control input 1 Logic box number 1 is used Setup Screen and Setup Items Press MENU to switch to setting mode and select the Menu tab gt Timer Event action gt Event action 2 13 09 Gap ALL BATCH Logic box number E ao Select 1 Event Remote BOT to number 1 1 Set the event to the reception of input by fiction HemoryStart Stop remote control input terminal 1 Target Action Select Set the action to the starting and stopping Batch Group No 2 of the recording of batch group 2 Input 1 zi Setting Target Action to All specifies all the batch groups Operation Starts and stops the recording of batch group 2 according to the input signal received by remote control input terminal 1 IM 04L41B01 03E Chapter3 Operations 3 1 Starting Stopping Recording and Saving Data Starting Recording from Batch Overview Mode Follow the procedure below when the batch overview mode screen is displayed 1 Press START The batch group selection window appears On DXs with the AS1 advanced security option recording will not start even if you press START in setting mode 2 Press the numeric soft keys that represent the batch groups you want to start recording LL seres OJER 3 BATCH 3333 PRODUCT A 1627 o p 19 o Green Recordin
23. calculated on computation channels separately for each batch group When you reset a calculated value the flags in use are also reset to zero Starting Recording and Computation Simultaneously You can start recording and computation simultaneously by using the START key Math start action when Math start is set to Start or Reset Start For the operating procedure see section 9 4 in the User s Manual When recording is started see section 3 1 computation also starts at the same time Starting Only the Computation Follow the procedure below when the batch overview mode screen is displayed 1 n operation mode press FUNC The FUNC key menu appears 2 Press the Math start soft key Computation starts and the computation icon is displayed in the status display section Stopping the Computation Follow the procedure below when the batch overview mode screen is displayed 1 n operation mode press FUNC The FUNC key menu appears 2 Press the Math stop soft key Computation stops and the computation icon in the status display section disappears Note Stopping recording does not simultaneously stop computations When you stop computations the calculated value for computation channels is retained as the value held immediately prior to computation stopping When recording this retained value is recorded Resetting Calculated Values Starting Recording and Resetting and Starting a Computation All at the Same Time For inf
24. cording and Saving Data Relay Output when Stopping Recording F1 and F2 Options When the relay action is set to memory sampling on a DX with the AS1 advanced security option relay output starts when memory start occurs for any of the batches and relay output stops when memory stop occurs for all the batches For an explanation of this feature s settings see section 2 9 in the User s Manual Recording Conditions for Each Batch Group You can use each batch group s recording status as variables MO1 to M12 in computations M1 and PM1 options For an explanation of this feature see section 1 8 in the User s Manual 1 4 IM 04L41B01 03E 1 1 Recording and Saving Data Recording Display Data and Event Data The following recording conditions are common to all batch groups For details on the recording operation see section 1 4 in the User s Manual Item Description all batch groups recorded for all batch groups batch groups mode batch groups Recording Manual Sampled Data and Report Data M1 and PM1 options The settings and behavior of these features are common to all batch groups For details on manual sampled data and report data see section 1 4 in the User s Manual Saving Measured Data to Storage Media This section briefly explains how the DX saves various types of measured data to storage media For shaded entries the DX performs the same operation as a DX without the Multi Batch function Fo
25. e 1 1 recording Staring om 3 1 recording starting and Stoppie 1 3 recording stopping ssessesssseseeeseeeennneeen nnne 3 4 report starting and stopping toten 1 3 report dala oce eire ie E NAESER 1 5 report data recording oo Int tere uei 1 5 GVISIOLIS acc nceitesi ti kno EiT BS FOE Nee IRE eee Raoul i S LLL settings changing during recording ssssssss 2 1 settings loading eerie i PIRE 3 18 status display Seco acce oot meere eher 1 8 1 10 storage media saving to sse 1 5 T ixi o 1 7 2 5 3 16 text field number eorr tttm eterne 2 5 MER nnana a eenestaeneneuwenie 1 7 2 1 urine E E EAE E EO TEE i trend clear ens 1 7 2 1 trend interval SWitchig irsinin ore reete 1 7 trend rate SWIECDIIC auctori rtp dte ee pez curate 2 1 AIP ING E ERE 2 1 2 5 U unsaved data SAVN girsier a e 3 18 USB flasti memoty con exeant aaia 3 18 We what this manual explains cceeeeeeeeeeeeeeeeeeeeneeeteeeeeeeeaes iii Index 2 IM 04L41B01 03E
26. ect All 3 Select Yes and press DISP ENTER PRODUCT A 1827 9887 o Yes w DISP T 5dmin DISP 1hour For details on starting reports and computations see section 1 1 IM 04L41B01 03E 3 1 Starting Stopping Recording and Saving Data Starting Recording from Batch Single Mode Follow the procedure below when the batch single mode screen is displayed 1 Press START The start recording screen appears On DxXs with the AS1 advanced security option recording will not start even if you press START in setting mode Confirm or change the batch number Batch name No and lot number and enter comments for the batch S i mrm O 12 09 06 5c or B Press DISP ENTER to start data storage Batch name No Lot No Comment suonejodo B To edit the contents of a text field proceed to step 3 Select Input and press DISP ENTER The text field screen of the specified batch group appears release numbers 4 and later 188 Text field number Title of field EY HE The settings that you made in setting mode appear here y 8 BAAL v Select a text field number enter text and press DISP ENTER The start recording screen will appear The text fields that you specify here will only be saved to the measured data file whose recording you are starting The text fields that you set in setting mode see page 6 6 will not change Move the cursor blue to START and press DISP ENTE
27. ft and Windows are registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries Adobe and Acrobat are registered trademarks or trademarks of Adobe Systems Incorporated Kerberos is a trademark of the Massachusetts Institute of Technology MIT Company and product names that appear in this manual are registered trademarks or trademarks of their respective holders The company and product names used in this manual are not accompanied by the registered trademark or trademark symbols and 1st Edition November 2008 2nd Edition March 2010 All Rights Reserved Copyright 2008 Yokogawa Electric Corporation IM 04L41B01 03E Conventions Used in This Manual Unit x A Markings gt WARNING CAUTION Note Subheadings Bold characters gt 7 3k Procedure Explanation Setup Screen Denotes 1024 Example 768 KB file size Denotes 1000 Improper handling or use can lead to injury to the user or damage to the instrument This symbol appears on the instrument to indicate that the user must refer to the user s manual for special instructions The same symbol appears in the corresponding place in the user s manual to identify those instructions In the manual the symbol is used in conjunction with the word WARNING or CAUTION Calls attention to actions or conditions that could cause serious or fatal injury to the user
28. g White or Black Not recording Setting Description amp 2 3 The batch group number All All batch groups currently not recording The start recording screen appears When You Select a Single Batch Group 3 Confirm or change the batch number Batch name No and lot number and enter comments for the batch um Qed ALL saroh OJER To edit the contents of a text field proceed to step 4 IM 04L41B01 03E 3 1 suonejedo B 3 1 Starting Stopping Recording and Saving Data 4 Select Input and press DISP ENTER The text field screen of the specified batch group appears release numbers 4 and later Text field number Title of field uc The settings that you made in setting mode appear here y B BAL v Select a text field number enter text and press DISP ENTER The start recording screen will appear The text fields that you specify here will only be saved to the measured data file whose recording you are starting The text fields that you set in setting mode see page 6 6 will not change Move the cursor blue to START and press DISP ENTER Recording starts for the selected batch group The internal memory icon in the status display section changes from the icon that indicates that memory sampling is stopped to the icon that indicates that memory sampling has started For details on starting reports and computations see section 1 1 When You Sel
29. ing historical trend MENU to switch to setting mode and select the File tab gt Load display data or Load event data gt press the CF or USB soft key gt select the file and press DISP ENTER Take note of the following points regarding loading of data You can load any batch group s data The historical trend is displayed on batch group 1 s historical trend screen When the display is split into two windows batch group 1 s trend is displayed as the current trend f you select Exit from the display selection menu and finish displaying the historical trend the DX returns to batch overview mode Using the FUNC Key You can use the FUNC key for the following operations For operating procedures see the reference for each respective operation Entries marked with a function the same as in batch single mode Operation Name Alarm ACK Executes alarm acknowledgement for all Section 3 8 in the User s Manual activated alarms Media eject Puts the external memory into a state in Operation Guide reet emen tcan oe serey removeatomte nx en Snapshot Saves the screen image data from the Section 6 6 in the User s Manual pese E display to a CF card in PNG format a Manual sample Saves the instantaneous values of all Section 6 5 in the User s Manual penser tome ee NN Save stop Aborts the manual data saving operation in Section 4 8 in the User s Manual pre dp e enr time ert Manit computation channels channels Passwo
30. ium see section 4 8 in the User s Manual This option is only displayed when it is available When the DX is configured to display DATA SAVE MODE on the display selection menu You can change the options shown on the display selection menu by using the menu customize function Load settings Switches to the setup load display in setting mode For instructions on how to load setup data see section 6 9 in the User s Manual Cancel Closes the operation selection window Removing the USB Flash Memory Device For the operating procedure to remove the USB flash memory device see section 2 12 in the User s Manual IM 04L41B01 03E Index Index Numeric 4 panel display rein reae e ER cea 1 7 A CIE VI pe applicable recorders A INCE MENT saec c eere ur rin rta er FEE c eEx te B gt batches NUMBER Of enrich e test 1 1 2 4 batch group operations you can perform on 1 7 batch group settings for each batch groups settings common to ssssssssss 2 1 batch overview esses nen nnne 1 9 batch overview mode cernere ret eta iere 1 8 3 9 batch singlemode rem nete 1 10 3 11 cello M 2 1 ooo calculated values resetting sess 3 6 change message ssssssssssesseesee eene nnne e SO m as computation starting computa
31. message Off Common Separate Message Settings For details on the message settings see section 5 4 in the User s Manual Writing a Message When the DX Recovers from a Power Failure For details on writing a message when the DX recovers from a power failure see section 5 16 in the DX1000 DX1000N User s Manual or section 5 17 in the DX2000 User s Manual Message gt Write group This setting applies only for messages that are written using keys Setting Description S Write the message to all the display groups for the batch group currently displayed Write the message only to the visible display group for the batch group currently displayed Automatically writes the message when the DX recovers from a power failure The message is written to all batch groups that are recording Example message 15 12 Power Off 2005 10 25 15 12 57 Description On DXs with the AS1 advanced security option a message is written when the setting mode setup items are changed during memory sampling On DXs without the AS1 advanced security option this setting is invalid Alarm setting change AlarmSet Alarm delay time change AlmDlaySet Calibration change Calibration correction Setting Disables the feature IM 04L41B01 03E 3 13 3 6 Writing Messages Procedure e Writing Messages or Free Messages For the operating procedure when the batch single mode is displayed see section 5 4 in the User s Manual
32. n Off Do not start computation using the START key Start computation Math start Start p of the Math start action Reset Start _ Reset and start computation Relay output Instrument Relay output when recording information stops output Starting and Stopping a Report M1 and PM1 Option The report feature starts when you start recording on any batch group and it stops when all batch groups stop recording Starting and Stopping Computation M1 and PM1 Option All computations start and stop together at the same time When computations are stopped you can start recording and computation at the same time Math Start Action Aclon SSCS Sn Starts computation Reset Start When starting Resets the values calculated on the each batch group selected batch group s computation separately channels Only the flags being used on the computation channels are cleared to zero The DX then starts computation again When starting Resets the values calculated on all all batch groups computation channels for the batch groups simultaneously that are not recording Only the flags being used on the computation channels are cleared to zero The DX then starts computation again The computation channels registered to that batch group s display group You can stop computation at any time IM 04L41B01 03E 1 3 uonounj uojeg nini eu jo uonduoseg 1 1 Re
33. nual EVENT SWITCH Shows the status of the Sections 1 3 and 4 5 in the event level switches User s Manual LOGIN Displays the history of Section 4 9 in the User s ERROR the respective operation Manual COMMUNICATION MAIL E SNTP MODBUS Operation log Change settings log Status Display Section With the following exception items shown in the status display section are the same as with a DX without the Multi Batch function 25 48 15 m ALL BATCH It 2 Displays the batch mode ALL BATCH refers to batch overview mode For details on the status display section see section 1 3 in the User s Manual 1 8 IM 04L41B01 03E 1 2 Display Batch Overview 5 S aLL earch S 1 BATCH 1234 Single batch group See below for details Sections outside of the range of the number of supported batch groups are displayed in grey DISP EESW 18min 2 BATCH 2222 DISP EENI 25min SAMPLE ABC 5 OFF DISP EENI 25min DISP hour Batch identification bar Displays the batch identification number and file header Blue Selected by using the arrow keys 1 BATCH 123d Recording status Green Recording White or Black Not recording Based on the background display settings For more details see section 5 12 in the DX1000 DX1000N User s Manual and DISP ES 18min section 5 13 in the DX2000 User s Manual Alarm icon Alarm status for the channels registered to the
34. open the display selection menu Use the arrow keys to select BATCH VIEW Press the right arrow key to open the submenu RON Use the up and down arrow keys to select a display type and press DISP ENTER The display changes to show only the selected batch group in the display type selected from the submenu 4 BATCH 4444 SAMPLE ABC 5 OFF DISP 1hour When Any Screen Other Than Batch Overview in Batch Overview Mode Is Displayed You cannot perform step 1 of this procedure Instead the batch group already selected on the batch overview is used for steps 2 to 5 Switching From Batch Single Mode to Batch Overview Mode Follow the procedure below when the batch single mode screen is displayed 1 Press DISP ENTER to open the display selection menu 2 Use the arrow keys to select BATCH OVERVIEW and press DISP ENTER The batch overview is displayed 3 8 IM 04L41B01 03E 3 4 Using Batch Overview Mode Follow the procedure below when the batch overview mode screen is displayed Procedure e Opening the Display 1 Press DISP ENTER to open the display selection menu 2 Use the arrow keys to select a menu item When there is a submenu select a submenu item and press DISP ENTER The selected display appears 15 30 c ALL BATCH OR E 3 BATCH 3333 EE ay fi i DISP 59min VERVIEW 4 BATCH 4444 Er OVERVIE SANPLE_ABC 5 OFF DISP 1hour BATCH OVERVIEW
35. or all activated alarms reset Manual batch group Free message Writes messages for the selected Section 3 6 in this manual batch group T ia ej Puts the external memory into Operation Guide a state in which it can be safely removed from the DX t Saves the screen image data from Section 6 6 in the User s Manual the active display to a CF card in PNG format T Manual sample Saves the instantaneous values of Section 6 5 in the User s Manual all channels Save display data Saves display data for the selected Section 3 1 in this manual batch group batch group T Save stop Aborts the manual data saving Section 4 8 in the User s Manual operation in progress Computation Resets the computed results of Section 3 2 in this manual reset all computation channels for the selected batch group T Math ACK Clears the computation data Section 9 4 in the User s Manual dropout display Edge switch Sets the event edge switch to on Section 7 1 in the User s Manual Resets the relative timer Section 7 1 in the User s Manual Match timer reset Resets the single match time timer Section 7 1 in the User s Manual Locked ACK Executes the Locked ACK IM04L41B01 05EN operation Key lock Locks or unlocks keys Section 8 1 in the User s Manual Logs off from the DX Section 8 3 in the User s Manual Password change Changes the password used to log Section 8 3 in the User s Manual on to the DX Batch Sets the batch name
36. ormation on starting recording and resetting and starting a computation all at the same time see section 1 1 Resetting the Values Calculated on All Computation Channels Follow the procedure below when the batch overview mode screen is displayed 1 Press FUNC The FUNC key menu appears 2 Press the Math reset soft key The values calculated on all computation channels are reset and all flags are cleared to zero IM 04L41B01 03E 3 2 Starting Stopping and Resetting Computations M1 and PM1 Options Resetting the Values Calculated on the Selected Batch Group s Computation Channels Follow the procedure below when the batch single mode screen is displayed 1 Press FUNC The FUNC key menu appears 2 Press the Math reset soft key The values calculated on all computation channels for the displayed batch group are reset Only the flags being used on the computation channels are cleared to zero The computation channels registered to the batch group s display group IM 04L41B01 03E 3 7 suonejedo B 3 8 Switching Between Batch Overview Mode and Batch Single Mode Procedure Switching From Batch Overview Mode to Batch Single Mode When Batch Overview Is Displayed 1 Use the arrow keys to select a batch group The selected batch group s batch identification bar is displayed in blue 3 BATCH 3333 DISP 58min 4 BATCH 4444 SAMPLE ABC 5 OFF DISP 1hour Press DISP ENTER to
37. ou want to stop data storage DISP N 58min DISP lhour 3 4 IM 04L41B01 03E 3 1 Starting Stopping Recording and Saving Data Stopping Recording from Batch Single Mode 1 Press STOP The stop recording screen appears 2 Use the arrow keys to move the cursor to Yes and press DISP ENTER Recording stops for the batch group When all batches stop recording the report function M1 and PM1 options also stops Batch name No SAHPLE B 2124 8801246 Comment suonej4odo B Automatically Saving Data For information on automatically saving data with the Multi Batch function see section 1 1 For details on the operating procedure see section 6 4 in the User s Manual Manually Saving Data For information on manually saving data with the Multi Batch function see section 1 1 For details on the operating procedure see section 6 4 in the User s Manual Saving Selected Data or All Data Stored in Internal Memory by Using Keys For information on saving selected data or all data stored in internal memory by using keys with the Multi Batch function see section 1 1 For details on the operating procedure see section 4 8 in the User s Manual IM 04L41B01 03E 3 5 3 2 Starting Stopping and Resetting Computations M1 and PM1 Options Procedure All computations start and stop together at the same time You cannot start or stop computations for each batch group separately You can reset the values
38. play selection menu see section 5 17 in the DX1000 DX1000N User s Manual and section 5 18 in the DX2000 User s Manual Settings are common to batch overview mode and batch single mode as well as common to all batch groups IM 04L41B01 03E 3 17 3 10 Saving to USB Flash Memory USB1 Option Procedure e Connecting USB Flash Memory 1 Connect a USB flash memory device to the DX USB port After the message USB device has been connected appears you can use the USB flash memory device 2 In operation mode the DX displays selectable memory operations Use the arrow keys to select an operation and then press DISP ENTER Batch Overview Mode When set to auto save When set to manual save IESU ALL saTcH a MB aut earch S 1 BATCH 1234 31 BATCH 3333 PRODUCT A 1827 9889 1 BATCH 1234 3 BATCH 3333 PRODUCT A 1827 9889 OFF OFF Cc Cc Load Settings Save Manual All Save Cancel Load Settings Cancel DISP 59min DISP 1hour DISP 59min DISP 1hour Batch Single Mode When set to manual save Iminzdiv Imin div DATA SAVE HODE Load Settings DATA SAVE MODE Cancel Load Settings Cancel Saves all the saved data in internal memory to the USB flash memory device Save manual Saves unsaved data in internal memory to the USB flash memory device Data save mode Switches to the DATA SAVE MODE display For instructions on how to save data in internal memory to an external storage med
39. r details on saving measured data to storage media see section 1 4 in the User s Manual Item Description Display data Saves the data from all batch groups to the specified save destination directory The same file save interval for display data is used for all batch groups Event data Saves the data from all batch groups to the specified save destination directory The same file save interval for event data data length is used for all batch groups Save display Saves the source batch group s display data that the DX is data currently recording to files on the inserted CF card Save event data Saves the source batch group s event data that the DX is currently recording to files on the inserted CF card Saving data using keys This operation is applicable when you insert a USB flash memory device or when you display the DX s memory summary and save data For details see section 3 10 in this manual or section 4 8 in the User s Manual IM 04L41B01 03E 1 5 uonoung 49eg HINN 94 jo uonduos q E 1 1 Recording and Saving Data Data file This section briefly explains the makeup of the data files Shaded entries are the same as with DXs without the Multi Batch function Description Display data Measured data Saves the data from each batch group to a separate file and event data Each batch group s alarm and message information is also saved File header The string specified for each batch group Ba
40. rd change Changes the password used to log on to the Section 8 3 in the User s Manual DX Text field Displays the text field for the batch group Section 3 8 in this manual that you select Builder screen Displays the custom display s builder IM04L41B01 04E screen Favorite registration Registers the current display as a favorite Section 3 7 in this manual Standard display Registers the current display as the Section 5 14 DX1000 standard DX display Section 5 15 DX2000 in the User s Manual System info Displays the system information screen Section 2 5 in the User s Manual Network info Displays the network information screen Section 2 5 in the User s Manual SNTP Synchronizes the DX s time with an SNTP Section 1 8 in the Communication server Manual E Mail start stop Starts or stops e mail transmission Section 1 4 in the Communication Manual of the transmission Manual FTP test Checks the connection between the DX and Section 1 7 in the Communication the FTP server Manual 3 10 IM 04L41B01 03E 3 5 Using Batch Single Mode Follow the procedure below when the batch single mode screen is displayed In batch single mode only the selected batch group s data is displayed Procedure e Opening the Display 1 Press DISP ENTER to open the display selection menu 2 Use the arrow keys to select a menu item When there is a submenu select a submenu item and press DISP ENTER suonejedo B TREND D
41. ss the Text field soft key The batch group number soft keys are displayed Press a batch group number soft key The text field settings appear Procedure in Batch Single Mode 1 In operation mode press FUNC The FUNC key menu appears Press the Text field soft key The text field settings for the currently displayed batch group appear 3 16 IM 04L41B01 03E 3 9 Changing the FUNC Key Menu and the Display Selection Menu You can change the contents of the FUNC key menu which is displayed when you press the FUNC key and the display selection menu which is displayed when you press the DISP ENTER key Procedure e Changing the FUNC Key Menu For details on the FUNC key menu when the Multi Batch function is enabled see sections 3 4 and 3 5 Using the FUNC Key suonejedo B For the operating procedure to change the FUNC key menu see section 5 17 in the DX1000 DX1000N User s Manual and section 5 18 in the DX2000 User s Manual Settings are common to batch overview mode and batch single mode as well as common to all batch groups Changing the Display Selection Menu For details on the display selection menu see section 5 17 in the DX1000 DX1000N User s Manual and section 5 18 in the DX2000 User s Manual BATCH OVERVIEW BATCH VIEW and ALL BATCH are already displayed in the topmost section of the display selection menu You can not change their positions For the operating procedure to change the dis
42. tch group are as follows You can find these settings on the Multi batch tab in setting mode Display group Trip line File header Data file name and Batch text General Settings Other Than the Specialized Settings for the Multi Batch Function Precautions The settings in setting mode excluding those on the Multi batch tab and the settings in basic setting mode are common to all batch groups Scan Mode You cannot set the scan mode to FAST Event Actions When the Multi Batch function is enabled a portion of the actions in the event action function requires the designation of a specific batch group For those types of actions a box containing all the batch groups for you to select from is displayed Actions that require MemoryStart Stop MemoryStart MemoryStop Message SaveDlsplay the designation of a SaveEvent MathReset DisplayGroupChange specific batch group Timer and Match Time Timer For DXs with the Multi Batch function you can use 12 timers and 12 match time timers Fixed Features You cannot change the following settings Trend rate switching Fixed to Off Fixed to On If even one batch group is recording the following settings cannot be changed Measurement range and memory sampling on off for measurement channels Expressions constants memory sampling on off and TLOG for computation channels M1 and PM1 options Measurement range and memory sampling on off for external input channels
43. tch text Batch text The string specified foreach batch group Manual sampled data Report data Idol File header The screen image data File Name You can specify a different file name configuration for each batch group For example you can specify that batch group 1 s file name is in the date configuration and batch group 2 s file name is in the batch configuration The file names for manual sampled data snapshot data and report data all follow the same configuration as that specified for batch group 1 For all file name configurations the sequence number portion of the file name for display data and event data differs from that used with a DX without the Multi Batch function For details on file names see section 1 4 in the User s Manual Configuration Description Date One character in the file name sequence number is Event data allocated to identify the batch group You can specify a different string to use in the file name per batch group Other file name details are the same as with a DX without the Multi Batch function Manual sampled The string used in the file name is the one specified for data batch group 1 Other file name details are the same as with Snapshot data a DX without the Multi Batch function Report data Serial One character in the file name sequence number is Event data allocated to identify the batch group You can specify a different string to use in the file name per batch group Other file
44. tion starting and stopping eessesssss 1 3 computation StODpIFlg ridere rer ener cete computation reset conventions used in this manual Do data automatically SAVING cceceeeeeeeeeeeeeeeeeeeeeeeteeeeeeaee 3 5 data saving manually taser ste aet ost retenir ce 3 5 Dra EE 1 6 data file NaMe cessisse net eg eseee data save mode ae displaydatan open neon er pene eer H reese display data loading e nte display data recording display data saving display group display gro p number iiioi ioco their te teret display groups number of nennen een 1 1 display selection menu changing sssessssss 3 17 E 4 Deje e aes even dala event data loadirigi cc cctools event data recording event dala Savirig icie neret ri en e etree E O FAST MOQO iimo osn a EEEE 2 1 MAW OUI OY aaea e eE EI EA E E 3 15 file head6r et are ax eet eei Eaa 2 5 TUG MAING T 1 6 filename examples rre reat Mites 1 7 file name sequence number ssssssesenee 1 6 FUNC key APINE reinaan eese pars e ER ER aedes 3 12 Alarm ACK Alarm display teset esee 3 10 3 12 rio 3 12 Builder Screen erronee ts 3 10 3 12 Computation reset erri 3 10 3 12 E Mail st
45. tructure of the file name when saving data Setting Description S Sequence number user assigned character string date Sequence number user assigned character string Sequence number batch name Data file name gt Identified strings Set the user assigned character string Up to 16 characters A at1 You can use these symbols 96 2 For an explanation of data file names see section 1 1 Text field number Select the text field number from 1 to 24 Text field gt Title of field and Text field gt Characters Enter a character string Title of field you can enter up to 20 characters for the field title Alal 1 Characters you can enter up to 30 characters for the field information gt m 3k IM 04L41B01 03E es HU Using the Event Action Function The event action function performs a specified action when a specified event occurs For example you can use the event action function to write a message when an alarm occurs When you use the multi batch function you have to specify the batch group to perform the action on In the above example you could configure the DX to write a message to batch group 2 when an alarm occurs When you configure an action that requires you to specify a batch group a box for selecting the batch group is displayed Setup Example Starting and Stopping the Recording of Batch Group 2 In the example
46. you cannot switch the trend interval you cannot switch to the secondary trend interval Trend clear When the Multi Batch function is enabled the DX always clears the displayed waveform when recording starts IM 04L41B01 03E 1 7 uonounj 49eg nini ay jo uonduoseg E 1 2 Display There is a batch overview mode and a batch single mode In batch overview mode information common to all batch groups is displayed In batch single mode information for each batch such as measured data and alarms is displayed Batch Overview Mode This section outlines the information displayed in batch overview mode Nam 1 1 Display Details Status display section See the following figure Section 1 3 in the User s Manual BATCH OVERVIEW Shows the status of all Section 3 3 in this manual batch groups See the figure on the following page CUSTOM DISPLAY Customized display IM04L41B01 04E screen OVERVIEW Shows the status of all Sections 1 3 and 4 4 in the channels User s Manual Manual MODBUS client Communication Manual MODBUS MASTER Shows the status of the Section 2 6 in the MODBUS master Communication Manual Shows the status of the Section 4 5 in the User s alarm output relays and Manual internal switches REPORT DATA Report data Sections 1 3 and 4 5 in the User s Manual COLUMN BAR Stacked bar graph for Section 4 10 in the DX1000 the report data User s Manual and section 4 11 in the DX2000 User s Ma
Download Pdf Manuals
Related Search
Related Contents
La recette des metiers_Guide accompagnement_12-03-2014 INSTANT-ER SUA48RMXLBP3U VITROCERAMIC HOB - User instructions VAŘIE ZE SKLOKERAMIKY PDES-02DX Manual - NPI Electronic Instruments Blaine-Gerät nach Dyckerhoff (Art.-Nr. 1.0210) einricHtungsanleitung Für den IP-basIerten entertaIn Cyber Acoustics MR-CB1402 DS-2CE56D1T-IRMM Philips FWM352 MP3 Mini Hi-Fi System Copyright © All rights reserved.