Home
        ODE User Manual
         Contents
1.   Glossary    ACN   Art Net     Dimmer     DHCP   ESP     HIP   IP   LTP     PC   RDM     Stream     Universe     Advanced Control Network     Artistic License network protocol  This 1s the Artistic License  DMX over Ethernet protocol     One discretely controlled device or parameter of a device out of  512 possible in the DMX512 protocol  Sometimes also referred  to as  Address      DMX Channel    or    Output Channel     Dynamic Host Configuration Protocol     Enttec Show Protocol  This is the Enttec DMX over Ethernet  protocol     Highest Takes Precedence   Internet Protocol     Latest or Lowest Takes Precedence  Context usually informs  which one is applicable      Personal Computer   Remote Device Management     A DMX512 over Ethernet Universe coming into or leaving the  ODE    512 addresses or slots of control information as conveyed   by DMX512 protocol  As a lighting system may have more than  512 discrete things to control  multiple universes may be  required  When this 1s the case  the Universe number will be  expressed in 0 255 form for ESP or 0 15 subnet and 0 15  universe   for Art Net     ODE User Manual 6    Introduction    Thank you for buying the ODE  At ENTTEC we are proud of our products and  we hope you will enjoy them as much as we enjoy making them     Firstly  unpack the unit from the box  You will find    e the ODE  which is a box containing all the electronics   e an external power supply  not included on the Power Over Ethernet model   e a CD contain
2. C DMX over Ethernet nodes    NMU bypasses all your TCP IP settings allowing you to reconfigure nodes in a  plug and play fashion  how ever they are configured     NMU V 1 34 supports the ODE starting with the V1 0 firmware   To employ the NMU  follow this set of instructions   1  If you have not already done so  install the program from the included  CD  or download and install this application from the Enttec website  http   www enttec com nmu nodemanagement    2  Ensure that your ODE is hooked up physically by Ethernet cable to the  same physical network as the computer on which you will run the NMU     This can be done directly to the port on your computer or through a  switch   When you plan to use multiple ODEs you will need to use a  switch     3  Start the application   4  Press the Discovery button     ODE User Manual 10    J Node Management Utility v1 34   ioii     IN s    Open DMX Ethernet 10 20 24 22 Open DMX Ethernet 000102030405    A    5  Select an ODE from the list of devices shown  your screen will differ  from example shown here to some degree         6  The configure button will now be enabled  press it to continue     ODE User Manual 11    7  The ODE Configuration Window will appear  It contains the controls  needed to make all possible changes to the ODE s configurations     ODE Configuration i X     Device Parameters Configuration    Protocol JartNet         Subnet  00     Universe Joo     Port Direction  Output DMX E    Save Config   Cancel   Update Firm
3. Open DMX Ethernet       User Manual    EN ITEC    www enttec com       Firmware V1 0 07 Dec 2008    This page Blank    ODE User Manual    Table of Contents    reris eee PD REA ROR eA ON EOE Re 4  reco du Oe Tot NIC o LU 4  WY AUT AEN c                                        TH 5   OGLOSSO y ieee ea eet eer ee ernest nee ae an IINE LIU a OE Ad LI nee 6  TV INI STO RN shes die testes E 7  I QUE Stocootietesascmtuiint iudico model E Qu La ete E eiuf ac atio tu atto t caress aceto 7  EO A EA EN AM ae eS 8   sites CONC 0  Utero ean eee c ee ee 8  Sonser gene TT                            R 8   PNO OUT oe e teu a gen ene meter iene E Cm ee 8    B   1 Hs eon pete ert Pere ent tery tere Meret prt re ettet ac omen ee an 9  CIC LEID SLA Qoare vas oacisestet E oto S db IE EM ue  9   Ethernet Hanneli 36e mites es pipes mtoep ab Qt mes ta pi educ ep Ido PD 9  EE DS                                                   9  NMU COD OUFA ON etes Ubera dest a 10  Updating the Application firmwate                    cccccccccccccccccesssaeceessssssessseeeeeeeeeees 16  Emergency Firmware updates uc eoo tuper eb tides ipd ipea te Ep edes 17  FANG     011 016 O ir                                         MO 19  APPEN D Rm Ret opr EIR en PE  gt  SEES Ft PEI M CM te MEME 20    ODE User Manual 3    Contents  When you open the packaging  you should find these items in the box     Open DMX Ethernet  pn 70305    Straight connect Ethernet lead  pn 79102  typically blue coating   Power Adapter  pn  79104   if 
4. ce may not cause harmful  interference  and  2  this device must accept any interference received   including interference that may cause undesired operation   This equipment has been tested and found to comply with the limits for a  Class B digital device  pursuant to Part 15 of the FCC rules  These limits  are designed to provide reasonable protection against harmful interference  in a residential installation  This equipment generates  uses and can  radiate radio frequency energy and  if not installed and used in  accordance with the instructions  may cause harmful interference to radio  communications  However  there is no guarantee that interference will not  occur in a particular installation  If this equipment does cause harmful  interference to radio or television reception  which can be determined by  turning the equipment off and on  the user is encouraged to try to correct  the interference by one or more of the following measures      Reorient or relocate the receiving antenna      Increase the separation between the equipment and the  receiver      Connect the equipment into an outlet on a circuit different from   that to which the receiver is connected      Consult the dealer or an experienced radio TV technician for                                              help   x In order to maintain compliance with FCC regulations shielded  cables must be used with this equipment  Operation with non approved       equipment or unshielded cables is likely to result in int
5. erference to  radio  amp  television reception     Appendix 2    We  ENTTEC Pty Ltd  Level 1  672 Glenferrie Rd   Hawthorn  Vic  3122  Australia    declare under our sole responsibility that our products     ODE  conforms to the requirements of Council Directives 89 336 EEC and 73 23 EEC and therefore complies with the requirements of Council  Directive 73 23 EEC   The Low Voltage Directive  on the harmonization of the laws of Member States relating to electrical equipment  designed for use within certain voltage limits as amended by Article 13 of Council Directive 93 68 EEC        EN 55103 1  e EN 50103 2      EN 60065 AS 3650    ODE User Manual 19    
6. ing the NMU program    e and this manual     If you are missing any parts  please contact the dealer through whom you  purchased the unit to arrange a solution     On the front of the ODE device  you will find     e RJ45 Ethercon connector for a 10 100 Base T Ethernet connection   e 4 Status LEDS   e DC OV input power jack for connecting the included Power Supply   not included on the POE Model     On the back you will find   e 1 DMX output connector  e   DMX input connector    The unit has no power switch and can be left on continuously     Features    e   DMX port with Male and Female connectors  e Setup done through Node Management Utility  e Supports ESP and Art Net protocols for DMX over Ethernet    ODE User Manual 7    Limitations    As the ODE 1s reliant on Ethernet  if you are using an existing computer  network and sharing the traffic between your lighting control system and other  functions  you may increase your exposure to potential delays in data  propagation  or a drop in the update rate  Specific strategies for better  implementing such large networks can be planned in consultation with Enttec  engineers if your application s scope warrants it     Basic Concept    While it has tremendous flexibility  right out of the box the ODE 1s factory  configured to be a DMX OUTPUT device  running on Art Net Universe 0 0  It  can be either output or input  however  and can use any possible universe in  Art Net or ESP modes  It has configurable IP address as well  Use the f
7. nd that you can Cick OK to refresh      Save Config   pue   pem   the list of devices which the NMU can    SCC          Firmware Update Status E X        JJ ODE Firmware Update Complete  Firmware was successfully updated to ODE    Click    OK to Refresh List       After you click the OK button  the update procedure is completed     ODE User Manual 16    Emergency Firmware update    In some rare cases  there firmware might become corrupted and support may  instruct you to force a firmware update  this is the procedure     Please Click on File  gt ODE Emergency Firmware Recovery    Firmware Update  Step 1    AJ Welcome to ENTTEC Emergency Firmware Update For ODE     Please disconnect ODE  Power OFF  before proceeding     Click Ok bo Continue       Select the file  then power the ODE    Firmware Update In Progress       Please Reconnect ODE  Power ON     Waiting Far ODE        Cancel       The firmware update may take a few seconds to start     Once finished you will see    ODE User Manual 17    Update Status    ODE User Manual      1   Firmware Update Complete    Firmware was successfully updated to ODE    Click  OK to Refresh List       18    Appendix 1    Federal Communications Commission  FCC  Declaration of Conformity       Responsible Party  ENTTEC Pty Ltd  Level 1  672 Glenferrie Rd   Hawthorn Vic 3122  Australia    declares that the products   Product Name  ODE    complies with Part 15 of the FCC Rules  Operation is subject to the  following two conditions   1  This devi
8. ree  utility program  Node Management Utility  to change configurations     Connector pin out    DMX OUT     Pin 1  Ground  Pin 2  Data    Pin 3  Data    Pin 4  NC   Pin 5  NC    DMX IN      Pin 1  Ground  Pin 2  Data    Pin 3  Data    Pin 4  NC   Pin 5  NC    ODE User Manual 8    Getting Started    When you power up the ODE for the first time  the default factory profile will  be as follows     DMX Port   It will be set to be an Output by default     Ethernet Channels     Out of the box  it will be bound to Universe 0  0  This 1s also known as  the first DM X Universe  There are 255 possible DMX over Ethernet universes  from which you can select one  These are also referred to as Streams in the  Node Management Utility     LEDs       1 Status  This LED will blink when the ODE is operating normally  If the LED  is on and does not blink it means the ODE is in fault  this could be due to a  failed firmware upgrade  You may need to scan your network with NMU and re  flash the firmware     If the LED off and you have power to the unit please contact ENTTEC support     2 Port Direction  The LED will be ON when the port is in Output mode and off  when the port is in input mode     ODE User Manual 9    3 Ethernet Link  This LED will be ON when there 1s an Ethernet Link     4 Ethernet Activity  This LED blinks when there is activity on the Ethernet  network     NMU configuration    NMU  Node Management Utility  is the free Windows and OS X application  used to manage compatible ENTTE
9. the outside of the box  perhaps  with tape and a permanent marker  or by using a plastic stick on label   so that you can deploy and troubleshoot it easily        ODE Configuration x ODE Config    Device Parameters Configuration    Device Parameters Configuration  Device Name   Open DMX Ethernet    paises  o  a  a  2    Device Name   Open DMX Ethernet  IP Address E  20  24  22    Protocol  Artet          12  If you re choosing to employ ESP protocol  your universe assignment 1s  a single step procedure with 256 choices in a single pull down list     ODE User Manual 14    SG SORE EERE SOON bONe       Gm    13  Select whether you need to output or input DMX information  or disable  it in rare instances  with the Port Direction setting           14  Once you have it all set up the way you d like  click on Save Config  button to send this information to the device     15  You can then close the application and use the ODE right away   Congratulations  you re done     ODE User Manual 15    Updating the Application firmware    To update the firmware on the ODE  you can perform a simple operation inside  the NMU program  Follow Steps 1 7 as described above in the NMU  configuration section  Then click the button at the bottom for Firmware  Update     A small progress window will pop up showing the percentage of completion  achieved as the procedure happens     Im Configuration       When it reaches 100  another  window will alert you that it  successfully completed this operation  a
10. ware          8  At your option  you may choose to enter a new name for the ODE in the  Device Name blank  Calling it    Truss 1    or    Onstage Dimmers  Universe  may be convenient to your application  for instance        9  If you need to adjust the IP Address for your application  it may be done  here  While many users can expect the ODE to work fine with factory  default IP  some networks will be a bit trickier  If it works for you as is   don t bother changing anything here  but if you re trying to troubleshoot   a valuable tip would be to choose an IP which 1s similar in the first 3  numbers  but distinct in the last  from other elements of your lighting  system  For further information about this consult a Network Manager  or IT expert who knows your local Ethernet setup well     ODE User Manual 12    10  Choose which protocol you wish to use  between Art Net  default  and  Enttec Show Protocol  or ESP   The ESP may be quicker and easier to  set up  but Art Net is supported very widely by other hardware and  software  so you have both options available     ODE Configuration x     Device Parameters Configuration    Open DMX Ethernet    IP Address   10  2   EJ  2    Protocol  aet         v        ODE User Manual 13    11  Assign your ODE to a Subnet and Universe in the Art Net range of  possible locations  If you only have one ODE  the default of 0 0 may be  suitable  but when multiple devices are used then take care as to which  you assign where  and consider labeling 
11. you have the POE option  the power adapter  is not included    User manual   CD  pn 79106     If one of these items 1s missing please contact your local dealer     Contacting ENTTEC   To contact us  please send an email to  contact  enttec com  Tel   61 3 9819 2433 GMT 10   Fax   61 3 9819 2733    To write us   ENTTEC Pty Ltd  PO BOX 282  KEW  VIC  3101  AUSTRALIA    ODE User Manual 4    Warranty    ENTTEC warrants that the product it manufactures and sells will be free from  defects in materials and workmanship for a period of 1 year from the date of  shipment from an authorized ENTTEC wholesaler  If the device proves  defective within the respective period  ENTTEC will repair or replace the  defective hardware at its sole discretion  If the failure is due to an operator error  the user accepts to pay for any charge relating to the diagnosis of the hardware   faulty parts or shipping from our factory     ENTTEC makes no warranty of any kind  express or implied  including  without limitation the implied warranties of merchantability and fitness  for a particular purpose  In no event shall ENTTEC be liable for indirect   special or consequential damages     Opening the unit voids the warranty as described above     AS this product uses ethernet as a communication medium  we cannot  officially support applications where the ODE is used on an existing  computer network  We recommend you have a good knowledge of  networking infrastructure and IP networking     ODE User Manual 5  
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
COMPASS    Samsung Celular Duos Voice manual do usuário    USER'S MANUAL XPRIM EVOLUTION BED  PDF, 1.8 MB - MONDAINE[モンディーン]−日本公式サイト  Broan-NuTone PM25 Kitchen Hood  manual de programación easy control  AMM Template 7.1 - Boehringer Ingelheim  Sportives de haut ni..    Copyright © All rights reserved. 