Quad-Relay Delay Switch (QRDS) User Manual (v1.0)

image

Contents

1. lighted doorbell switches or similar devices since current may leak through the bulb resulting in inadvertent activation Indicators There are five onboard LED indicators as desbribed below e Green LED This LED is a system status indicator slow blinking firmware is active e Solid activated e Fast blinking pending activation e Red LEDs There are four 4 red LEDs which provide an indication of relay activation status as follows e Off No activation no trigger condition e Solid relay activated e Fast blinking trigger condition present relay activation is pending following prescribed delay Note If an activation is pending the trigger condition must remain active for the entire duration of the delay period Otherwise the activation will be cancelled and the timer will be reset Configuration DIP Switches The QRDS 1000 contains six 6 available configuration DIP switches The individual switch assignments are identified in the photo below RPNW SPS UD Switches may be adjusted using a miniature screwdriver or similar implement Available parameter settings are listed below Relay Activation Delay Relay Deactivation Delay Piezo Beeper Enable Pulse Input Enable Input Trigger State Notes 1 The device should be powered off prior to making DIP switch setting adjustments 2 Use caution when adjusting settings to avoid damaging individual switches Parameter settings are described in detail below e Relay Act
2. Quad Relay Delay Switch QRDS User Manual v1 0 Introduction The QRDS 1000 Quad Relay Delay Switch provides general purpose control for up to four independent devices It also offers optional activation and deactivation delays via configurable onboard DIP switches The product provides four 4 wired control inputs and is operated standalone without the need for a host PC The following control methods are provided e External switch closures e Discrete TTL inputs The product is useful in a variety of applications including the following Security Access control Automation Industrial control HVAC Lighting Pumps Robotics Features The product has the following features Four 4 form C relays with N C N O and COM contacts see not below Four 4 wired control inputs accept switch closure or TTL signal LED indicators for visual relay activation status Configurable activation delay 1 to 3 minutes Optional deactivation delay 1 to 3 minutes Configurable external switch type normally open normally closed Accepts optional digital pulse input Piezo buzzer for audible alert enabled via DIP switch Accepts optional AC adapter 12VDC Optional slimline enclosure with mounting flange Hardware Overview The QRDS 1000 features a printed circuit board with digital microcontroller and required peripherals The microcontroller continuously monitors the four switch inputs and provides relay activation control wit
3. The General Purpose Quad Relay Delay Switch is easily installed e Remove the two retaining screws which attach the enclosure lid to its base if supplied Connect wiring for your equipment under control to relay contacts at terminal blocks TB 1 to TB 4 Refer to the Wiring section for details Connect input control wiring at terminal block TB 5 Refer to the Wiring section for details Configure optional delays piezo enable and or other settings using the onboard DIP switches Mount the unit on a wall or other surface and attach using compatible screws not included Apply 7 to 12VDC power using compatible AC adapter 500 mA minimum Optionally you may supply power at TB 5 terminals 1 amp 2 e Re attach the lid if supplied External Switch Wiring The QRDS 1000 provides a screw terminal block TB 5 for wiring up to four 4 external switches You may also interface TTL signals from a microcontroller or other device The photo below identifies applicable terminals Ext Input 1 Return 1 Ext Input 2 Return 2 Ext Input 3 Return 3 Ext Input 4 Return 4 To wire an external switch connect it as described below Normally closed Switch TB 5 Contact Terminal N C Ext Input N COM Return N Normally open Switch TB 5 Contact Terminal N O Ext Input N COM Return N The complete listing of TB 5 screw terminal definitions is given below TB 5 Control inputs 12VDC In Out Grou
4. cation For instance a home alarm system might typically use a normally closed switch at each door or window These switches would be wired in series forming a circuit If any door or window is breached the circuit would be opened causing the relay to sound an alarm and or activate flood lights On the other hand a normally open sensor switch might be expected for an automatic sump pump application The switch closes when the water level gets too high causing the relay to activate the pump To select the desired switch type set the applicable DIP switch listed below Switch Type Sw 6 Normally Closed Dn Normally Open Up Notes 1 The normally closed selection requires jumper wires at all unused external switch inputs Jumpers are unnecessary for the normally open setting For example consider an application using three 3 normally closed switches which are wired at external inputs 1 2 amp 3 with correponding return wires Since external input 4 is unused a jumper would be applied from this terminal to return 4 Refer to External Switch Wiring for details 2 For TTL inputs choose normally open for active low signals or normally closed for active high signals The normally closed selection requires jumpers for all unused external signal inputs as explained in the previous note 3 A switch in the down position designates Normally closed while the up position indicates Normally open Hardware Installation
5. h specified relays The following photo depicts key elements of the device Activation LEDs Digital Controller TB 3 Relay Wiring Power Source The QRDS 1000 accepts an input voltage range of 7 to 25VDC which may be provided at TB 5 screw terminals 1 amp 2 In addition an onboard barrel jack is provided for use with compatible AC adapter Inner pin is positive polarity Recommended plug dimensions 2 1mm I D 5 5mm O D Note Power should be applied at either the screw terminals or the barrel plug never both at once Operation A relay is activated by trigger input due to external switch action e g switch closure Either normally open or normally closed switches may be used Refer to section Configuration DIP Switches for details If an optional activation delay has been configured the relay will not engage until the delay expires If the trigger input returns to its pre activation state before that time e g switch opens the pending activation will be cancelled and the delay timer will be reset Once activated the relay remains engaged until the trigger condition has cleared i e external switch opens or TTL signal returns high If optional deactivation delay has been enabled the relay will remain engaged until the delay expires The deactivation delay will be the same duration as the configured activation delay Notes 1 Triggers may also be optionally initiated by TTL signal 2 Do not use
6. itch To enable deactivation delay set the DIP switch as shown below Deactivation Delay Sw 3 Enabled Dn Disabled Up Note A switch in the down Dn position designates enabled while the up position denotes disabled e Piezo Beeper Enable An onboard piezo beeper if installed provides audible annunciation when a relay activation occurs To enable the piezo set the applicable DIP switch listed below Beeper Sw 4 Enabled Dn Disabled Up Note A switch in the down position designates Enabled while the up position denotes Disabled Pulse Input Enable The QRDS 1000 may accept external switch closure or TTL inputs Some devices may deliver a pulsed TTL output rather than a constant voltage Enabling pulse input processing allows the onboard digital controller to properly interpret this signals for subsequent relay activation To enable pulse inputs set the applicable DIP switch listed below Pulse Input Sw 5 Enabled Dn Disabled Up Notes 1 This setting is applicable to each of the four available wired inputs 2 Pulsed signals must have a minimum frequency of 1 Hz 3 A switch in the down position designates Enabled while the up position denotes Disabled External Switch Type Relay engagement trigger will occur following activation of an external input switch The QRDS 1000 can accept the following switch types e Normally open e Normally closed The type you use is likely to be defined by the appli
7. ivation Delay An optional activation delay may be configured using onboard DIP switches 1 amp 2 Activation delay defines the amount of time that the trigger input must remain enabled before the relay will engage A delay of 0 implies no activation delay and will cause the relay to enage immediately This delay will be invoked when any trigger input becomes active and effectively postpones relay engagement for the specified period of time The trigger must remain active for the entire time period Otherwise relay engagement will be cancelled To configure the activation delay set the DIP switches up or down according to listing below Activation Delay Sw 1 2 0 none Up Up 1 min Dn Up 2 min Up Dn 3 min Dn Dn e Relay Deactivation Delay An optional deactivation delay may be specified in conjunction with the activation delay described above The deactivation delay is configured using onboard DIP switch 3 This delay will be invoked following a relay activation and will keep the relay engaged for a period of time after the trigger input becomes disabled high The period of time that the relay will remain engaged is equal to the activation delay described above configured at switches 1 amp 2 For example a configured activation delay of 2 minutes will result in a deactivation of the same duration If there is no activation delay i e 0 then there will be no deactivation delay even if enabled at the DIP sw
8. nd 5VDC out Ext Inpu Gnd retur Ext Inpu Gnd retur u r u r 100mA max Ext Inp Gnd retu Ext Inp Gnd retu not used not used Ground hb DOWMDATNAUBRBWNEH DB WWNHNEE DGD C8 gt Gr 2 Ct pa j ot iita GAE oot NE Re SE SF A eR oe PRR e wN Notes 1 Screw terminal 1 is indicated by a small white square imprinted on the circuit board beside the connector 2 External input connections can accept external switch closure or TTL input 3 Only a subset of the given terminals will be needed for any given application Relay Wiring Four 4 terminal block connectors are provided for relay wiring purposes TB1 through TB4 The photo below identifies the terminals corresponding to individual relay contacts 1 Normally Closed 2 Common 3 Normally Open Screw terminal definitions for each of the four relays are listed below TB 1 Relay 1 Contacts 1 N C 2 COM 3 N O TB 2 Relay 2 Contacts T N E 2 COM 3 N O TB 3 Relay 3 Contacts 1 N C 2 COM 3 N O TB 4 Relay 4 Contacts 1 N C 2 COM 3 N O Notes 1 Screw terminal 1 is denoted by a small white square imprinted on the circuit board beside the connector 2 Relays have a specified 10A capacity but board traces limit actual capacity to 5A Maintenance The product requires no special care or maintenance other than protection from direct exposure to moisture power surges sta
9. tic electricity weather and other hazards Warranty This product is warranted for a period of 90 days from the date of purchase and is guaranteed to be free from defects The warranty covers the entire unit except if any part or component has been modified or otherwise converted from its original form The warranty does not cover damage or failure due to neglect improper use or unshielded exposure to the elements Note The customer is responsible to provide protection against static electricity and over voltage situations including power surges spikes and lightning strikes The use of a surge protection at the AC power source is strongly encouraged Disclaimer Kadtronix and Delahoussaye Consulting shall not be held liable or responsible for incurred damage or injury which may result due to the use or misuse of this product Contact Information Should you have any questions or comments please contact us at Ken Delahoussaye Senior Engineer Consultant Delahoussaye Consulting http www kadtronix com kdelahou kadtronix com 321 757 9280