1. Hone Pass Fail Home Locale Hoch Capture Image Live Image m E Magnity and Enlarge vnde I Figure 20 Sample Obstruction Overlay Grading Circles To show or hide grading circles click the Show Hide Grading button The grading circles zones are based on the IEC 61300 3 35 specification Using the grading circles provided as a guide the technician can judge and mark a fiber endface image Pass or Fail by clicking the appropriate button If no grading is desired press the None button Figure 21 None Pass Fail and Show Hide Buttons The grading circles can be centered on the fiber core by pointing the mouse at core center and right clicking or by clicking the Locate button They also can be nudged left right up or down by first clicking the fiber image then using the arrow keys on the keyboard Pressing and holding the Shift key and pressing the arrow keys will move the grading circles ten pixels at a time The grading circles can be resized by first clicking the fiber image and then using the mouse wheel or by pressing and holding the Ctr key and pressing the Up or Down arrows on the keyboard ODM Optical Design Manufacturing Inc 20 ODM Optical Design Manufacturing Inc Figure 22 Grading Circles Displayed Figure 23 Grading Circles and Pass Displayed 21 OPM Hold Read Clicking the OPM Hold Read button will freeze or resume the live reading streamed from the OD
2. On the top header portion of the reports there is a space for a company name The name that is entered into the Customer Company Name space on the Report Settings tab will be used to fill the header Vastu for posent enti ba be plugged in andi tured cn Figure 16 inSpec Report Settings Tab ODM Optical Design Manufacturing Inc 17 Pass Fail Settings Tab Loss measurement pass fail limits can be set and enabled on this tab as shown in Figure 17 If a limit is en abled and the power meter measurement exceeds that set limit the measurement is marked as Fail on the reports e ee SE G l Mm RA A s P y UE a ert miis TUE Figure 17 Pass Fail Settings Tab Help Tab The Help tab contains the inSpec version number and software manual It also contains user specific guides and endface zone details ETE ei ee E ELTE m ER E epis Te st Sool ine R mri Se lings ete Licht ae oll J vr octet pei 7 Ley Figure 18 Help Tab ODM Optical Design Manufacturing Inc 18 OD Vl Performing a Test Automatic Analysis To perform automatic grading connect the fiber to the VIS 400 HDP and focus the image If the fiber needs to be cleaned clean it using a dry or wet dry method and reconnect the fiber to the VIS 400 HDP focus and press the Analyze button The inSpec software performs and reports the analysis by comparing defects to the IEC61300 3 35 specification and reports Pass or
3. 400 HDP It is included with Windows XP SP3 Windows Vista Windows 7 and Windows 8 Installation of Videology Driver for the VIS 300 and VCM 410 Both the ODM VIS 300 and VCM 410 require a Videology Windows driver for proper operation If the serial number on the VIS 300 or VCM 410 has a C appended to the end navigate to the Videology Windows 32 64 bit Cypress folder of the installation package double click on SetupVid and follow the installation instructions If there is no C after the serial number then go to web page http www videologyinc com download htm and download the SFT 04040 Windows driver and follow the installation instructions ODM Optical Design Manufacturing Inc IV Connecting ODM Devices to Your PC Test Equipment The VIS 400 HDP or VIS 300 can be used for visual inspection with the ODM inSpec software The RP 460 power meter can be used to record power dBm or loss dB measurements VIS 400 HDP Visual Inspection Scope Plug the VIS 400 HDP into a USB port on the PC Power is supplied by the USB port Wait for Windows to load the UVC driver You should see Windows report a message indicating the driver loaded successfully VIS 300 Visual Inspection Scope Using the supplied USB cable plug the ODM VIS 300 into a USB port on the PC Apply power to the device Wait for Windows to load the driver you installed in the previous section You should see Windows report a message indicating the Videology Camer
4. Capture Image File Screen ODM Optical Design Manufacturing Inc 11 Live Image If a saved or analyzed image is displayed on the main tab clicking on the Live Image button will display the live stream from the VIS 400 HDP or VIS 300 Enlarge Clicking the Enlarge button will display a larger version of the image displayed on the main screen as shown in Figure 7 below Click the Windows X button in the upper right corner or click the Exit button to close the Enlarge image window ote nca ND CC tm Click to Close Window B Figure 7 Enlarged Image Window Magnify and Center Clicking the Magnify and Center button magnifies the image displayed approximately 2 5 times and centers the fiber end face See Figure 8 below To return to the normal view click the Full Field of View button oA E Gm Main Reports Tesi Sellimgs Report Settings Pass Fail Satlings Help ODM inspec Live kraga kom USR 2 0 Camera vs UPC HERREN Analyze Capbura Image Leve Image Enkadg Wieirey T pe piver meter to be plogqaed es ari iuan en Figure 8 Magnify and Center Screen ODM Optical Design Manufacturing Inc 12 Voice On Off Voice commands can be used in situations when both hands are busy Voice commands can be turned on and off by clicking the Voice Commands button When on command feedback is given as illustrated in Figure 9
5. Fail with the number of defects that caused a failure in each zone on the fiber endface Defects that are colored in blue were found but are smaller than the specified defect size limit for the zone and are not considered a failure Defects colored red are equal to or larger than the specified size and cause a failure See IEC 61300 3 35 2009 specification for more information To show detailed information about a defect mouse over the defect so that a pop up window appears below the Pass Fail box in the upper left hand corner See Figure 19 To change the specification that is used to determine pass or fail choose the Test Settings tab and choose the desired specification before performing a test Figure 19 Automatic Grading Screen E Optical Design Manufacturing Inc 19 Manual Grading Grading Obstruction Overlay The overlay is used to judge the size of any particles or scratches in the grading zones The zones are based on the IEC 61300 3 35 specification Clicking the Show Grading button will display grading circles as illustrated below The overlay can be moved by clicking and dragging on the top bar of the overlay To move the overlay to the home position the lower right hand corner of the image click the Home button Siob rc 0 0 g ee Main Reports Test Seltings Report Settings Pass Fail Settings Help ODM ihspec
6. M RP 460 power meter OPM Save To save the power meter measurement first select one or two fiber end images on the Reports tab and click OPM Save on the Main tab You will be prompted by the screen in Figure 25 Hint Press and hold the Ctrl key and click the image if you want to select two images Wiis foe power meter io be plugged ie andi quemad on Figure 24 Two Fiber End Images Selected Loss Measurement Prompt The Loss Measurement prompt assists you when saving power meter measurements for reports When you choose No in Figure 25 you are indicating the measurement is just for the trunk portion of the cable If you choose Yes you are indicating that the measurement includes the top sector jumper RR Location Mri 1 P increment Automatically Y Peaae endure the locaton number ia comect The meos sofware wil ube This number te cere repertis Figure 25 Loss Measurement Location Prompt Always Just Trunk Disabled ODM Optical Design Manufacturing Inc 22 Pinca eare the canon nmiber i correct The nepon EWT iil use the number 225 create epi Figure 26 Loss Measurement Location Prompt Always Just Trunk Enabled Location Number Indicates the location you are making the measurement for example location 1 of 12 It is important that you enter the correct location number if you do not your reports will not be accurate Increment Automatically Check this if you want the location number to inc
7. MEE 1248 es To 128 0 06 dB 4 1310 Loss Turk Cable 0 06 dB 1310 D 32 dB amp 1310 Trunk 0 3248 amp 1310 Trunk and sector rooftop omm Trunk and sector rootton Figure 28 VIS Report Screen 5 OD Optical Design Manufacturing Inc 24 Site Loss Report If you have Microsoft Excel installed on your computer clicking on the Site Loss Report button will create a site loss report of all the optical power measurements made that are associated with the end face images presently displayed in the selected folder Q M Spec Site Loss Report Customer Name Contact Name Testing Company Tester s Name Customer Company Name Contact Name Testing Company Name Tester Name Test Location Tuesday January 21 2014 9 34 50 AM Fibers From Fibers To 1AB 12AB Pass Fail Settings 850 Min Max 0 0dB 3 0dB ENABLED 1310 Min Max 0 006 3 0dB ENABLED 1490 Min Max 0 00B 3 0dB ENABLED 1550 Min Max 0 0dB 3 0dB ENABLED RP 460 02 RP 460 Test Data Location Comment TEE 850nm Unit 1310nm Unit 1490nm Unit 1550nm unit 1a Trunk and sector rooftop No 2 B8 dB 2a Trunk and sector rooftop No 3 83 Fail dB 3a Trunk and sector rooftop No 2 95 dB 4a Trunk and sector rooftop Ne 2 95 aB od Trunk and sector rooftop Ho 2e 14 aB ba Trunk and sector rooftop No 2 90 dB Ta Trunk and sector rooftop No 290 dB ga Trunk and sector rooftop No 2 90 dB ga Trunk and sector rooftop No 0 04 dB 10a Trunk and sector rooftop No 0 60
8. ODM Optical Design Manufacturing Inc Fiber Inspection and Testing Procedures Technical Support Document Table of Contents l PURE WO aieiaa A R EE E r Ai ANE a Eaa aaa 3 II PS SUITS US ceirean a tater canna e vania cits AE A EA AA EAER 5 Il VS OSC InstalatON seco nail TEN Iaturddian Gu modia immu aie datur Hsu DD DES RUM PE THRUS 6 IV Connecting ODM Devices to your PC ccccccsseeeceee eese 8 V MSDEC T CY RIEN RO RLERRRERERPETTTE 9 VI Pe rtorming a MT ci RENCONTRE 10 VII Technical SHBDDOLL oasis emet dictar ebrnc std etin indiam ro dO UAE 11 ODM Optical Design Manufacturing Inc Il Introduction When connected to ODM s VIS 400 HDP VIS 300 USB or VCM 410 USB field connector inspection system the ODM inSpec software allows users to inspect and save fiber endface images and pertinent data inSpec also provides automated Pass Fail analysis according to the IEC 61300 3 35 industry standard See the image below for an example of the automated Pass Fail analysis inSpec offers Maintaining clean fiber endfaces is essential to the proper function of fiber optic systems ODM inspection microscopes provide clear high resolution images to be analyzed using the inSpec software This manual will serve as a guide to the installation and use of the software to complete closeout reports BEFORE CLEANING AFTER CLEANING Auto analyzed images from VIS 400 using inSpec software ODM Optical Design Manufactu
9. S 400 HDP Probe utilizes the UVC 1 1 driver included with Windows No other driver installation is needed Videology driver for ODM VIS 300 or VCM 410 e Serial Port Support If ODM s RP 460 power meter is to be used FTDI serial port driver can be downloaded from http www ftdichip com Drivers CDM CDM20824 Setup exe ODM Optical Design Manufacturing Inc Ill inSpec Installation CD Installation 1 Insert the ODM inSpec CD into a PC running Windows 8 Windows 7 or Windows Vista 2 If the program does not start automatically open the ODM VIS folder on the CD 3 Double click setup exe and follow the software installation instructions Web Installation 1 Go to http www odm inc com Downloads html 2 Click the Download button for ODM Complete Software Package 3 Choose Save 4 After the download completes view download 5 Choose Run 6 Choose Unzip 7 After the ODM Installer starts choose Install 8 Follow the installation instructions Microsoft NET Framework If you are prompted for a newer version of NET Framework and you are not provided with a link during inSpec installation it can be downloaded from Microsoft at http www microsoft com download en details aspx id 24872 Alternately it is included on the inSpec installa tion CD in folder Microsoft NET Framework 4 To install it double click on dotNetFx40 Client x86 x64 1 Microsoft Visual C Redistributable If you are prompted that you need to install Mic
10. When the command feedback box is green the command was understood Yellow indicates that a command was understood but may have been misinterpreted Red indicates the command was not understood Below are a few voice commands that can be used rather than clicking on a button Button VoiceCommand Capture Image or Cheese Hold or Read Magnify and Center Center Image or Full View Voice Commands Off Disable Voice For these commands you can use the same command to toggle between button states For example When you say Center Image inSpec will magnify and center the image Rather than saying Full View you can say Center Image again to return back to full view ME COM riper 7 mmm Main Reports Test Settings Report Sellings Pass Fail Settings Help DM inspec Analyze Captura Image Leve Image ios Magnify and Enaga Contr Mica n Exit Bebar S eo pier meler 16 be plsgaedl e andi tend en Figure 9 Voice Command Feedback ODM Optical Design Manufacturing Inc 13 Focus Bar The blue focus bar is located below the fiber end image on the Main tab It is visible when a live image is displayed and the image is not totally blurred It is an aid to help focus the image When the focus ring on the ODM probe is rotated and the image becomes more focused the red peak bar stays at the
11. a driver loaded successfully RP 460 Optical Power Meter Plug the RP 460 into a USB port on the PC using the supplied USB cable Apply power to the device Wait for Windows to load the driver you installed in the previous section You should see Windows report two messages indicating the drivers loaded successfully ODM Optical Design Manufacturing Inc V inSpec Overview Starting inSpec Run ODM inSpec by double clicking on the inSpec icon on your desktop Figures 3 and 4 illustrate the func tions for each item on the main screen Tab Selection i dh PASS FAIL Live or Saved m Indicator Image Display Reports Tost Sellina Window ODM inspec hnaWze e N TE Automatic Analysis ay edis Button TL f Optical Power Meter Control and Measurement Tab Selection ccs chem PASS FAIL Indicator Live or Saved Image Display Window Reports Test Sattings Sample Obstruction Overlay Circles Live Image Pass Fail Buttons Hide Show Grading Canter Magnity an Vow Ott Exil Vel bE Dr Matar E Hold Status Bar E Vee ms gb o Wisiting tex M Optical Power Meter Control Focus Bar and Measurement Figure 4 inSpec Functions Manual Grading Mode d ODM Optical Design Manufacturing Inc 10 Tool Tips Holding the cursor over a button wil
12. best focus achieved Each time a new peak is reached the image associated with the peak is saved in a temporary buffer If the image becomes unfocused again after a peak is reached the peak focused image is still saved When the Analyze button is pressed the best focused image is used not the image displayed at the time the Analyze button was pressed This helps to ensure the best focused image is used for the analysis Figure 10 Unfocused Fiber End domm ge iem iui Dr cama a Figure 11 Focused Fiber End Hem umen mm LEER DO Carme Figure 12 A Focused Image is Needed to Perform a Successful Automated Analysis Exit inSpec will close when the Exit button is clicked ODM Optical Design Manufacturing Inc 14 Reports Tab The Reports tab contains the list of saved fiber end images Using these images there are two reports that can be created VIS Reports and Site Loss Reports VIS Report information includes fiber end face image s and power meter measurements for the selected test Site Loss report creates an Excel report of all the images stored in the present selected folder Tising ce pasen mente 13 br plugged in and tumed on Figure 13 Reports Tab VIS Report Button To create a VIS report select one or two fiber end images and click VIS Report To include power measurements in a report the technician must first select one or two images that he or she would like t
13. dB 11a Trunk and sector rooftop Ne 0 05 dB 12b Trunk and sector rooftop No 0 05 dB r nnk and sector roaoattarp hn IOS dB Figure 29 Site Loss Report ODM Optical Design Manufacturing Inc VII Technical Support 25 If you need technical assistance or have specific questions about any procedures or guidelines in this guide please contact our technical support team During Business Hours 8AM to 5PM Eastern Standard Time Please call us at 603 524 8350 Evenings Weekends Email us at tech support odm inc com Please include your phone number and we will contact you On YouTube Visit our YouTube page for helpful videos Visit Our Website www odm inc com ODM Optical Design Manufacturing Inc
14. is in the manual analysis mode You can adjust image bright ness contrast sharpness and gamma using these controls Figure 14 Image Controls IEC Profile 61300 3 35 When performing a test using automatic analysis technicians must choose the IEC specification to compare defect sizes and locations The specification is used to determine whether the end face passes or fails the test Main Reports Tost Settings Report Settings Pass Fail Settings Help Test Setbngs Analysis Modo Fiber Typo Mftomatc Manual Single Mode Mult Mode Enable Hint on Start in Manwal Mode Video Source IEC Profile 61300 3 35 OOM HDP Probe ORE Mult Mode PC Camera Settings Single Mode APC c bee Single Mode PC RL 26dB ete Manus Vang for power meter to be plugged e and turned on Figure 15 inSpec Test Settings Tab S OD Optical Design Manufacturing Inc 16 Report Settings Tab The Report Settings tab contains information to help annotate a saved fiber end face image Test Information Drop down boxes contain information that is likely to be repeated These lists can be added to by clicking the Add button next to the item These are labeled Customer Company Name Contact Name Testing Company Name Tester s Name and Test Location To delete an item from a list select the item and press the De button next to the item Text boxes labeled Fibers From Fibers To and Comment can be updated to reflect the test location
15. l display a tool tip describing its function See Figure 5 Center Chek te migrer ares cenie Tht EN Figure 5 Tool Tips Main Tab The Main tab contains all of the functions to perform a test but before starting a test the technician should set up the appropriate settings by selecting the settings tabs See the Settings Tabs descriptions below Analyze After the appropriate setup has been selected under the settings tabs the technician can perform an analysis of a fiber end face The Analyze button is enabled when a fiber cable is plugged into the ODM VIS 400 HDP and it is focused Capture Image When a live image is displayed in the image window the Capture Image button will be enabled on the Main tab Clicking on Capture Image will cause the Save File window to open Here you can create a new folder to save the image or save it to an existing folder When a fiber end image is saved the information under the Report Settings tab Customer Company Name for example is saved as well Clicking on any of the saved images will load that image and the information about the image into inSpec When a report is created the customer information is reported with the image i Save As 0 uL m Lo Libraries Pictures Test03132012 9 Search Test 02132012 n e Pictures library a furange by Folder Test 03132012 Test New Folder X Save as type jpg files jpg z T Figure 6
16. o associate with the power measurement then click the Save button on the Main tab when an ap propriate loss measurement is displayed Site Loss Report Button Creates an Excel Report of all fiber end images in the selected folder Clear Check Boxes Button Clears all check boxes Change Folder Button Permits the technician to change or create a new folder Ideally a folder should be created for each test site Doing this will allow site loss reports to be created easily ODM Optical Design Manufacturing Inc 15 Test Settings Tab The Test Settings Tab contains options that control the analysis mode camera settings and IEC specifications for the automatic analysis Analysis Mode To change the mode of grading click the Test Settings tab and choose Automatic or Manual in the Analysis Mode group If a VIS 300 is selected for a video source you will not be allowed to choose the Automatic mode Fiber Type The two types of fiber the technician may choose are single mode and multi mode To ensure that the correct size critical zone is used during analysis the technician must choose the correct fiber type Single mode diam eter is 25um multi mode is 65um Video Source The technician can select a video source by clicking on the drop down box in the Video Source group ODM probe names are ODM HDP Probe USB 2 0 Camera and Videology Camera Camera Settings Image controls are only available when inSpec
17. rement by one every time you make a measurement and save it to an image file Reset Resets the Location Number to 1 Always Just Trunk Check this if your measurements are always trunk and do not include the top sector If checked you will not be prompted for top sector measurements as shown in Figure 26 Change Folder To change the folder where images are saved or to create a new folder click Change Folder Figure 27 Change Folder Window ODM Optical Design Manufacturing Inc 23 Reporting inSpec permits the user to create reports Two types of reports are provided VIS Report and Site Loss Report The VIS Report information includes fiber end face image s and power meter measurements for the selected test The Site Loss Report information includes all the tests for the folder selected and displayed at the bottom of the inSpec screen Figures 28 and 29 illustrate these reports VIS Report Clicking on the V S Report button will display results similar to the figure below To display the results you must first select one or two images in the image list before clicking VIS Report Hint Hold Ctr key while clicking to select two images GDM paves Loss Report Customer Company Name Report Date 9 15 58 AM Tuesday January 21 2014 Test Data avs Testing Company Name esting Compan Testing Company Name Tester Name Testers Mam ties bns Test Location est Locat Test Location D ES
18. ring Inc CDM Infgec k i s g m A ss 2 Main Reports Test Setlings Report Settings Pass Fail Settings Help lores lrg Treen CHM HI Prales Captura Image Live Image Magnity and Center Waiting for power meter 2n be pkogged in and tuned on Figure 1 inSpec Main Screen Landscape Mode inSpec Tablet Support inSpec is designed to be touch friendly and supports screen rotation to make it more convenient when used with tablets Figure 1 illustrates the main screen in the landscape mode Figure 2 illustrates the main screen in the portrait mode In this manual all subsequent figures will be illustrated in the landscape mode but the operation of inSpec will be the same in the portrait mode Only the button sizes and locations are changed to accommodate the differ ent orientation ODM Optical Design Manufacturing Inc E x Main Reports Test Settings Report Settings Pass Fail Settings Help ODM h spec Live lenage from ODM HDP Probe Capture Image Live Image Analyze Enlarge Magnify and Center Wating for power meter to be plugged in and turned on Figure 2 inSpec Main Screen Portrait Mode Il Requirements Operating System Compatibility e Windows 8 e Windows 7 e Windows Vista Software Requirements e Microsoft NET Framework 4 or newer e Microsoft Visual C x86 Redistributable Windows Driver Requirements e Imager Support The ODM VI
19. rosoft Visual C Redistributable and you are not provided with a link during inSpec installation it can be downloaded from Microsoft at http www microsoft com en us download details aspx id 5555 Alternately it is included on the inSpec instal lation CD in folder Microsoft C Redistributable To install it double click on vcredist x86 exe ODM Optical Design Manufacturing Inc Manual Installation of inSpec Software If you want to install inSpec manually you can do so by navigating to folder ODM VIS on the installation CD and double clicking setup exe If you downloaded the software from ODM s website http www odm inc com Downloads html extract the files on your PC by running the installer After the installer is finished close it then navigate to C ODM Software VIS and double click on setup exe Manual Installation of Software Drivers Before connecting your ODM devices to your PC please load the required drivers by following the instructions below Installation of FTDI Chip Driver for the ODM RP 460 To install the FTDI Chip Windows driver for the RP 460 navigate to the FTDICHIP folder of the CD included in the installation package and double click on CDM20824 Setup and follow the installation instructions If you don t have a CD you can download the FTDI Chip driver at http www ftdichip com Drivers CDM CDM20824 Setup exe Installation of UVC Driver for VIS 400 HDP No driver installation is required for the VIS

Download Pdf Manuals

image

Related Search

Related Contents

Jahresschaltuhr Expert 1 Kanal GPS / Annual    MANUAL DE USUARIO EN ESPAÑOL Versión 1.1  5 Le syst`eme d`exploitation Unix/Linux - storage.neros.fr2015-10  xerion 3300 3800 - CLAAS Selection Premium  MEULE A EAU Réf 10144  Participatory Carbon Monitoring: Manual for Local People  StarTech.com USB 3.0 to SATA Hard Drive Docking Station for 2.5/3.5 HDD  Honeywell 500 Automobile Parts User Manual  FAST EDDY`S BARGEQUE OVEN  