1. Fire Safe Wall Pads fixed no exposed fasteners shall be a minimum of 2 inch polyethylene foam covered with heavy 15 ounce fire retardant high tensile vinyl coated polyester fabric material bacteria resistant washable with a damp cloth Cover material shall be designated as flame resistant in accordance with NFPA 701 The cover material shall have a tear strength of 100 P S I Mounted to 7 16 inch thick high density oriented strand backing board Total panel thickness 2 7 16 Entire pad assembly has been tested and meets the requirements of NFPA 101 Life Safety Code for Class A rating flame spread 0 25 smoke development 0 450 when tested in accordance with ASTM E 84 also published as NFPA 255 ANSI 2 5 UBC 8 1 and UL 723 Typical size of individual panels 24 inches wide Size as shown on drawings Provide all required wall attachment clips Mat colors as selected from manufacturers 14 standard colors Equal to Porter Model 00575 1 2 FireSafe Wall Pad Fire Safe Corner Pads fixed no exposed fasteners shall be a minimum of 2 inch polyethylene foam covered with heavy 15 ounce fire retardant high tensile vinyl coated polyester fabric material bacteria resistant washable with a damp cloth Cover material shall be designated as flame resistant in accordance with NFPA 701 The cover material shall have a tear strength of 100 P S I Mounted to 7 16 inch thick high density oriented strand backing board Total panel thickness 3164
2. 1 Provide wire guards where indicated on drawings 2 18 by 18 size for nominal 16 inch diameter analog clocks 3 Primex model 14123 SNS Automated Bell Scheduling System 1 Provide Automated Bell Scheduling System software platform that allows the setup and management of bell schedules System manages and monitors the bell schedules and the synchronization with clocks 2 Network enabled relay that automates existing bells or tone equipment with the Automated Bell Scheduling System 3164 28 33 23 8 BUILDING PACKAGE ADDENDUM 2 3 Ethernet Bell System Relay Provides system synchronization with mechanical bell system 4 Connect network bell relay to public address system Mount inside public address rack 3 Fight 8 separate user programmable time zones shall be provided by a software scheduling program 6 Schedule and program the bell system as directed by the school district A time zone directory shall be provided on the computer monitor 7 System shall provide a minimum of 500 discrete time event entries for class passing tones Each entry shall contain the time of day the day or any combination of days in the week the time zone or any combination of eight 8 time zones and the time schedule or any combination of eight 8 time schedules I Network Bell Relay 1 Physical a Dimensions 4 13 H x 3 34 W x 2 83 D b Weight 0 75 Ib 2 TO Interfaces a 2 relay outputs 240 VAC 5A b 4 digital inp
3. 11 66 26 2 BUILDING PACKAGE ADDENDUM 2 2 7 16 Entire pad assembly has been tested and meets the requirements of NFPA 101 Life Safety Code for Class A rating flame spread 0 25 smoke development 0 450 when tested in accordance with ASTM E 84 also published as NFPA 255 ANSI 2 5 UBC 8 1 and UL 723 Typical size of individual panels 24 inches wide Size as shown on drawings Provide all required wall attachment clips Mat colors as selected from manufacturers 14 standard colors Equal to Porter Model 00575 1 2 FireSafe Wall Pad C Colors Submit samples for selection by Architect PART 3 EXECUTION 3 1 INSTALLATION A Mount on walls as recommended by manufacturer Locate as directed in locations shown on drawings B Provide all on site cutouts for panels electrical outlets etc Installation shall be made in accordance with factory procedures END OF SECTION 11 66 26 3164 28 33 23 1 BUILDING PACKAGE ADDENDUM 2 SECTION 28 33 23 WIRELESS CLOCK SYSTEM PART 1 GENERAL 1 1 1 2 1 3 APPLICABLE PROVISIONS A Drawings and general provisions of contract including general and supplemental conditions and Division 1 specification sections apply to work of this section APPLICABLE PUBLICATIONS A Conform to requirements of current ANSI NFPA 70 National Electric Code B Conform to current Underwriters Laboratories UL Specifications and Standards C Conform to current Telecommunication Indus
4. 2 Section 2 S5 12 Change the note TOS 123 4 to TOS VARIES 123 4 TO 123 0 Change the vertical dimension 1 4 to VARIES 1 8 TO 1 4 ARCHITECTURAL Sheet A1 3 First Floor Plan Unit A 1 CLARIFICATION added dimensions and note to concrete risers below stairs see attached revised sheet A1 3 2 CLARIFICATION added note to plan for display case see attached revised sheet A1 3 3 REVISED dimension string in reception to dimension to column grid line A16 see attached revised sheet A1 3 4 CLARIFICATION added callout and revised note at cooler freezer in kitchen see attached revised sheet A1 3 5 REVISE location of column line A18 and column to match structural change see above structural revision see attached revised sheet A1 3 Sheet A1 4 First Floor Plan Unit B 1 ADDED additional locations to receive corner guard see attached revised sheet A1 4 Sheet A1 5 Second Floor Plan Unit A 1 ADDED additional locations to receive corner guard see attached revised sheet A1 5 Sheet A1 6 Second Floor Plan Unit B 1 ADDED additional locations to receive corner guard see attached revised sheet A1 6 Sheet A1 7 Roof Plan 1 ADDED additional roof drains see attached revised sheet A1 7 2 ADDED roof ladder to roof plan see attached revised sheet A1 7 3 ADDED detail 2 A1 7 for roof ladder see attached revised sheet A1 7 4 ADDED areas of tapered insulation to roof plan see attached
5. 3 Page 2 in section 2 3 B 4 REVISE Nominal Opening Size 12 wide by 8 0 high as Nominal Opening Size 13 wide by 8 0 high 173 N BROADWAY G MILWAUKEE WI 53202 o PHONE 414 226 0200 www brayarch com 3164 Black River Falls Elementary School Addendum 2 Page 3 BUILDING PACKAGE CHANGES TO THE DRAWINGS GENERAL Sheet G0 2 General Notes amp Wall Types 1 In Wall Type B amp B REVISE note 6 METAL STUDS 24 O C as 6 METAL STUDS 16 O C and REVISE note 3 SOUND ATTENUATION BLANKET as 6 SOUND ATTENUATION BLANKET 2 In Wall Type C amp C REVISE note 3 5 8 METAL STUDS 24 O C as 3 5 8 METAL STUDS 16 O C 3 In Wall Type D amp D REVISE note 3 5 8 METAL STUDS 24 O C as 8 METAL STUDS 16 O C 4 In Wall Type D amp D OMIT 7 3 4 dimension at top of detail 5 In Wall Type F amp F REVISE note 3 SOUND ATTENUATION BLANKET as 8 SOUND ATTENUATION BLANKET CIVIL None STRUCTURAL Sheet S0 4 Plan Details 1 Detail 9 S0 4 Change the dimension 1 8 to 1 8 1 2 Detail 11 S0 4 Change the title from CP 03 PIER DETAIL to CP 11 PIER DETAIL 3 Detail 13 S0 4 Change the two 4 dimension to 3 Change the 1 3 dimension to 1 2 Change the vertical column GRID mark to A24 Change the bottom horizontal column GRID mark to AC C
6. 33 23 3 BUILDING PACKAGE ADDENDUM 2 6 The Automated Bell Scheduling System platform is a locally configured server appliance that can be installed by the Owner s IT department in an existing building or installed by an IT or electrical contractor during new construction As an alternative to the locally configured server appliance the owner may license server software from manufacturer and deploy a Virtually Configured System 7 The system distributes device firmware upgrades at the time system devices synchronize and communicate diagnostic information to the server appliance Manufacturer offers extended system maintenance agreements for firmware upgrades 9 Software revisions are provided under the manufacturer s Software Maintenance Agreement OF RELATED WORK ELSEWHERE A Division 26 27 and 28 Electrical B Division 27 51 25 Public Address System SHOP DRAWINGS A Submit shop drawings in accordance with Section 26 05 04 B The following information shall be submitted in addition to items listed above 1 Submit complete product catalog data for each component describing physical characteristics and method of installation Submit brochure showing available colors styles sizes and finishes of clocks 2 Submit sample of one specified system device model s for approval Approved sample s shall be tagged and shall be installed in the work at location directed 3 Submit manufacturers complete installation set u
7. A Clean surfaces soiled by work as recommended by manufacturer B Remove surplus materials and debris from the site DEMONSTRATION A Demonstrate proper operation to Owner s Representative B Instruct Owner s Representative in maintenance procedures END OF SECTION 08 33 25 3164 11 66 26 1 BUILDING PACKAGE ADDENDUM 2 SECTION 11 66 26 SAFETY WALL PADS PART 1 GENERAL 1 1 1 2 1 3 RELATED DOCUMENTS A Drawings and General Provisions of the Contract including General and Supplementary Conditions and Division Specification Sections apply to this section B Comply with Wisconsin Commercial Building Codes International Building Code IBC C Comply with Americans with Disabilities Architectural Guidelines and ICC ANSI A117 1 Latest Edition SUMMARY A Provide safety wall pads and corner pads complete with installation accessories where detailed B Panel shall meet ASTM Standard F2440 impact protection C Panel shall meet ASTM E 84 Class A fire certification D Panel shall meet NFPA 286 fire certification E Installation shall be in accordance with ASTM F2440 SUBMITTALS A Submit in accordance with Section 01 33 00 Submittal Procedures PART 2 PRODUCTS 2 1 2 2 MANUFACTURERS A Porter Athletic Equipment B Basketball Products International C Draper Inc D Performance Sports Systems E Promats Athletics F Spalding Basketball amp Gymnasium Equipment PRODUCTS A 2
8. INDICATED ROOM OR SPACE GENERAL NOTES 1 ALL SPRINKLER HEADS LOCATED IN LAY IN GEILINGS SHALL BE LOCATED IN CENTER OF CEILING WHERE SPRINKLERS ARE LOCATED IN A PAINTED SOFFIT WOOD SOFFIT OR CEILING THE FIRE PROTECTION CONTRACTOR SHALL OBTAIN A COLOR SAMPLE FROM THE ARCHITECT AND HAVE THE COVER PLATE AND ESCUTCHEON FACTORY PAINTED TO MATCH ADJACENT SURFACE FIRE PROTECTION PIPING WITH OTHER DISCIPLINES 4 ALL FIRE PROTECTION SYSTEMS SHALL BE DESIGNED PER NFPA 13 5 FIRE PROTECTION CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR ELEVATIONS CEILING HEIGHTS AND REFLECTED CEILING PLANS FOR ALL AREAS 6 ALL FIRE PROTECTION CONTRACTORS ARE RESPONSIBLE FOR COMPLYING WITH LOCAL CODES AND AMENITIES TO NFPA 13 7 ITIS THE RESPONSIBILITY OF THE FIRE PROTECTION CONTRACTOR TO PREPARE ALL FINAL DRAWINGS CALCULATIONS AND SUBMITTALS TO THE AUTHORITY HAVING JURISDICTION Wiwaukas Project Title Issue Dates Project Number 215 North Water Street 7 30 2015 Suite 250 bray Miwaukee w ss202 Black River Falls Elementary School architects Sheet Number vison wana rarezz6ne0 Black River Falls School District AD2 FP1 F 414 226 0224 wav brayarch com 410 County Road A Black River Falls WI
9. PLAN MOUNTED TO JAMBS REFLECTED CEILING PLAN ROLL UP DOOR o j PER MFR REQUIREMENTS MOUNTED TO WALL 5 f y a PER MFR REQUIREMENTS A WA sasa fo Z Z p z 4 AN gf MASONRY WALL NA gt MASONRY WALL a i T O LI 5 if a x gt e gt FINISHED SOFFIT SEE ul FINISHED SOFFIT SEE H REFELCTED CEILING PLAN D REFLECTED CEILING PLAN ace SEE STRUCT DWGS FOR Z TH mx l li aa kai o o VERIFY hi Tha VERIFY Pi MASONRY WALL JAMB BEYOND no a 5 8 GYP BOARD SHE RCP amp VERIFY W 5 8 GYP BOARD SEE STRUCT DWGS FOR D oc EE RCP amp VERIFY W LINTEL O lt OH COILING DOOR MOTOR x S 5 g OH COILING DOOR MOTOR Ee m ab m ROLL UP DOOR amp TRACK ui A o Mm co LU a Ka Da I 355 gt a F S I 7 re ko 8 O DOG O o5 w fea SF o 71 Issue Dates N A8 2 7 30 2015 SEE PLAN Ly A 8 14 2015 Addendum 2 SEE KITCHEN EQUIP I STAINLESS STEEL RUN STAINLESS STEEL COUNTER H PASS THRU COUNTER CONT OVER WALL I CONT ALONT WALL BY KITCHEN EQUIP Pd CONTRACTOR 7 l CMU WALL JAMB BEYOND t ROLL UP DOOR 8 TRACK TURN STAINLESS STEEL DOWN OVER FRONT OF WALL 4 MIN GRIND ALL I O EDGES SMOOTH N z 2 X WOOD SILL T Lu E CMU WALL I FINISHED FLOOR EO LI FINISHED FLOOR SEE ROOM FINISH SCHEDULE s m go aa NG e Project Number SEE PLAN 3164 mi Roll up Counter Door Roll up Overhead Door Sheet Number 9 Sc
10. and or timer and every other component in the system shall use both precise time and synchronized time Digital clocks shall be synchronized to within 10 milliseconds every 10 minutes and the system shall have an internal oscillator that maintains plus or minus four seconds per day between synchronization so that clock accuracy shall not exceed plus or minus 0 2 seconds Analog Clocks shall be synchronized to within 10 milliseconds 6 times per day when operating clock strikes 2 01 AM 6 01 AM 10 01 AM 2 01 PM 6 01 PM and 10 01 PM and the system shall have an internal oscillator that maintains plus or minus one second per day between synchronization so that clock accuracy shall not exceed plus or minus 0 2 seconds The system shall include an internal clock reference so that failure to detect the master time source shall not result in the clocks failing to indicate time Additionally XR transmitters will have an internal battery backup of up to eight hours in the event of a power failure so that settings and the correct master time will be instantly recalled upon restoration of power System shall incorporate a fail safe design so that failure of any component shall not cause failure of the system Upon restoration of power or repair of failed component the system shall resume normal operation without the need to reset the system or any component thereof If transmitter stops transmitting valid time signals due to power failure the clo
11. conflicts with the work of other trades prior to installation of work Adjust system to satisfy field requirements Clocks shall not be installed until painting and other finish work in each room is complete DELIVERY STORAGE AND HANDLING A Deliver all components to the site in the manufacturer s original packaging Packaging shall contain manufacturer s name and address product identification number and other related information B Store equipment in finished building unopened containers until ready for installation C Protect finished installation until final acceptance of the project INSTALLATION A General Install system devices in accordance with applicable codes B Configured system software in accordance with manufacturer written instructions C Provide all system equipment necessary for a complete and operable system D Master Time Source 1 Connect CAT6 EIA TIA standard Ethernet cable from transmitter LAN port to available network drop 2 Set GPS LAN DIP switch to NTP E Transmitter 1 Locate transmitter where indicated a minimum of 5 to 6 feet above the floor away from large metal objects such as filing cabinets lockers or metal framed walls 2 Transmitter will be placed at locations indicated within specifications and drawings 3 Connect antenna to transmitter using care not to strip threads 4 Connect power supply to the transmitter 5 Set the channel number on the display to correspond to the FCC l
12. doors RELATED SECTIONS A Division 05 Section Metal Fabrications B Division 06 Section Rough Carpentry C Division 06 Section Finish Carpentry D Division 07 Section Air Barriers E Division 07 Section Joint Sealants F Division 08 Section Finish Hardware G Division 09 Section Interior Exterior Painting and Transparent Finishing H Division 26 Electrical wiring and conduit fuses disconnect switches connection of operator to power supply and installation of control station and wiring SYSTEM DESCRIPTION A Design Requirements 1 Cycle Life a Design doors of standard construction for normal use of up to 20 cycles per day maximum B Products That Are Supplied But Are Not Installed Under This Section 1 Control Station SUBMITTALS A Submit in accordance with Section 01 33 00 Submittal Procedures B Submit the following items 1 Product Data 2 Shop Drawings Include special conditions not detailed in Product Data Show interface with adjacent work 3 Quality Assurance Control Submittals a Provide proof of manufacturer ISO 9001 2000 registration b Provide proof of manufacturer and installer qualifications see 1 4 below c Provide manufacturer s installation instructions 4 Closeout Submittals 3164 08 33 25 2 BUILDING PACKAGE ADDENDUM 2 a Operation and Maintenance Manual b Certificate stating that installed materials comply with this specification QUALITY AS
13. sheet A6 6 3 CLARIFICATION revised notes or dimensions in details 12 16 amp 17 A6 6 see attached revised sheet A6 6 4 REVISED detail 18 A6 6 see attached revised sheet A6 6 Sheet A6 7 Interior Details 1 In detail 10 A6 7 REVISE note 1 4 CLEAR TEMPERED GLASS as 1 2 CLEAR TEMEPERED GLASS Sheet A6 8 Interior Details 1 REVISED reveals in details 4 amp 5 A6 8 see attached revised sheet A6 8 173 N BROADWAY G MILWAUKEE WI 53202 o PHONE 414 226 0200 www brayarch com 3164 Black River Falls Elementary School Addendum 2 Page 6 BUILDING PACKAGE Sheet A6 9 Interior Details 1 REVISED notes in detail 2 A6 9 see attached revised sheet A6 9 2 CLARIFICATION added dimension to detail 11 A6 9 see attached revised sheet A6 9 3 REVISED details 8 amp 10 A6 9 see attached revised sheet A6 9 Sheet A7 1 Interior Elevations 1 CLARIFICATION revised added notes tags and or dimensions in elevations 1 13 15 16 amp 17 A7 1 see attached revised sheet A7 1 Sheet A7 2 Interior Elevations 1 REVISED acoustical panels in elevation 6 A7 2 see attached revised sheet A7 2 2 CLARIFICATION added typical dimensions in elevations 8 A7 2 see attached revised sheet A7 2 Sheet A7 3 Interior Elevations 1 CLARIFICATION revised added notes tags and or dimensions in elevations 1 2 3 4 5 10 4 11 A7 3 see attached revised sheet A7 3 Sheet A7 4 Interior Elevat
14. the clocks on computer networks and devices from either a public server or a separate server on a private local area network 2 SNS Synchronous Network System 3 UTC Universal Coordinated Time 4 PC Personal computer Owner furnished I Clock System Description 1 System shall continually wirelessly synchronize clocks and shall be capable of clock readouts in multiple time zones where desired 2 System shall operate on a 72MHz frequency The 72MHz frequency transmitter efficiently sends time synchronization signals through commercial building materials to ensure all devices receive important time updates even for Daylight Saving Time and after a power outage 3164 28 33 23 2 BUILDING PACKAGE ADDENDUM 2 The system transmitters can be configured with a variety of power output levels to provide coverage for a single building The system supports an FCC license for operation of a 72MHz transmitter result in safe and interference free operation for users System shall provide wireless time from a master time source This time source will be from a defined NTP server via a wired Ethernet network connection that the XR transmitter can access via the customer Local Area Network LAN The master time will be synchronized to UTC Hard wiring for data communication will not be required to the clocks installed for the system Clocks shall automatically adjust for Daylight Saving Time in locations where DST is observed Each clock
15. 29 11 1 2 5 6 7 N D Or pe w N Near North end of Gym Change the note 44LHSP1 to 48LHSP1 Near Center of the Gym Change the note 44LHSP2 to 48LHSP2 Near the South West wall of the Gym Add an Angle Frame below the Roof Hatch and relocate one 16K3 joist 8 Near column grid lines BF B18 Resize and relocated roof hatch frame Steel Lintel Schedule Add the Mark L 02 Type A Size W8x10 PL REINF 1 2x7 10 Non Load Bearing Masonry Lintel Schedule Add the schedule refer to the revised sheet 1 9 Sheet S5 1 1 Add Section 18 S5 1 Sheet S5 4 1 Section 22 S5 4 Change the note TOS 123 4 to TOS VARIES 123 4 TO 123 0 Sheet S5 6 1 Section 5 S5 6 Change the notes 44LHSP1 to 48LHSP1 and 44LHSP2 to 48LHSP2 Sheet S5 10 1 Section 1 S5 10 Turn the metal floor deck 90 Degrees to the direction shown eliminate the beam and the note BEAM SEE PLAN 2 Section 2 S5 10 Turn the metal floor deck 90 Degrees to the direction shown eliminate the beam and the note BEAM SEE PLAN Sheet S5 11 1 Section 2 S5 11 Omit the wide flange beam at the roof and omit the note W BEAM SEE PLAN Sheet S5 12 1 Section 1 S5 12 Add the HSS8x4x1 4 Girt add the bond beams and reinforcing change the top of wall elevation as shown on the revised section 173 N BROADWAY MILWAUKEE WI 53202 o PHONE 414 226 0200 www brayarch com 3164 Black River Falls Elementary School Addendum 2 Page 5 BUILDING PACKAGE
16. 40 all heads in this room to be concealed heads symbol 1 HVAC Sheet H1 0 3 Revise size of RG 2 in Grilles and Diffusers schedule 173 N BROADWAY MILWAUKEE WI 53202 o PHONE 414 226 0200 www brayarch com 3164 Black River Falls Elementary School Addendum 2 Page 8 BUILDING PACKAGE Sheet H2 1 1 Revise size of RG 2 in Cafeteria A121 per the revised drawing Sheet H2 2 1 Revise supply duct main size coming out of Storage B139 and branch main running to the North per the revised drawing Sheet H2 4 1 Revise supply duct main size coming out of Storage B239 and branch mains running to the North and South per the revised drawing ELECTRICAL Sheet E1 8 Second Floor Unit B Power 1 ADD wireless clock transmitter receptacle and data jack to Data B217 2 ADD plan note 20 173 N BROADWAY G MILWAUKEE WI 53202 o PHONE 414 226 0200 www brayarch com 3164 08 33 25 1 BUILDING PACKAGE ADDENDUM 2 SECTION 08 33 25 COILING SERVICE DOORS PART 1 GENERAL 1 1 1 4 RELATED DOCUMENTS A Drawings and General Provisions of the Contract including General and Supplementary Conditions and Division 01 Specification Sections apply to this section B Comply with Wisconsin Commercial Building Codes International Building Code IBC C Comply with Americans with Disabilities Architectural Guidelines and ICC ANSI A117 1 Latest Edition SUMMARY A Section Includes Electric operated overhead rolling
17. 6 hours the second hand will five step as a visual indicator that the signal has been lost Should the clocks lose power and signal the clocks will not function 9 Analog clock receivers shall be as follows a Receiver sensitivity gt 110 dBm b Receiver power AC powered 120VAC c Antenna type internal d Antenna gain 7 dBd 10 Clocks shall be electric AC powered 120 VAC model as specified in models specifications 11 Electric AC models will include a cord with plug 12 If power is interrupted the clock will stop until power resumes Upon resumption of power the clock will self correct to the current time 13 Provide wire guards 14 Primex model 14339 Digital Clocks 1 Digital Clock display must include a 12 or 24 hour time display a PM indicator light and an alternating time and date display option 2 Dual face with ceiling dual clock bracket Primex model 4XBRK 3 Digital Clock shall be capable of automatically adjusting for Daylight Saving Time 4 Digital Clock shall be electric AC powered 120 VAC model as specified in models specifications 5 Electric AC models will include a cord with plug 6 Digital Clock must be viewable from 150 feet 45 7m 7 Digital Clock must have highly visible 7 segment LED digits 8 Digital Clock shall have display dimmer options including 75 50 and 25 9 Digital Clock 4 digit display 4 high red LED digits 10 Primex model XRA1B201 Clock Wireguards
18. BLACK RIVER FALLS ELEMENTARY SCHOOL 410 COUNTY ROAD A h ra BLACK RIVER FALLS WISCONSIN ly PROJECT NO 3164 CD architects solid foundation forward thinking Bray Associates Architects Inc Milwaukee amp Sheboygan Wisconsin August 14 2015 ADDENDUM NO 2 BUILDING PACKAGE This addendum is issued to explain modify or correct the original drawings and Project Manuals and is hereby made a part of the Contract Documents Please attach this Addendum to the Project Manual in your possession Insert the number and issue date of this Addendum in the blank space provided on the Bid Form CHANGES TO THE PROJECT MANUAL Section 04 20 00 Unit Masonry 1 Page 5 in section 2 2 D 1 REVISE item d to read as follows d Running bond pattern 2 Page 5 in section 2 2 D 2 REVISE item d to read as follows d Running bond pattern 3 Page 2 under section 2 10 A 8 ADD item c to read as follows c Bayer Material Science Bayseal CCX Closed Cell Spray Applied Polyurethane Foam Insulation with W R Meadows Air Shield Joint Filler Air Shield Thru Wall Plashing and Pointing Mastic Section 07 21 00 Thermal Insulation 1 Page4 under section 2 1 G 8 ADD item a to read as follows a Bayer Material Science Bayseal CCX Closed Cell Spray Applied Polyurethane Foam Insulation with W R Meadows Air Shield Joint Filler Air Shield Thru Wall Plashing and Pointing Mastic Section 07 53 27 Fully Adhered EPDM Roof Syste
19. ENT A B 3164 28 33 23 5 BUILDING PACKAGE ADDENDUM 2 When power is first applied to the transmitter it checks for and displays the software version It then checks the position of the switches and stores their position in memory The transmitter looks for the master time source Master Time Source Operation 1 NTP Time Source With the transmitter in NTP mode it connects over the Ethernet to the IP address of the NTP server This IP address is programmed into the transmitter as part of its configuration Once the connection to the NTP server is acknowledged it downloads time data and synchronizes its internal master clock to NTP time The transmitter then starts to transmit its internal time once every second The transmitter updates its internal clock in this mode once per hour Clock Operation 1 After initial setup the clock and or timer will shut off the receiver Six times each day an Analog Clock microprocessor will activate the receiver and starting with the stored channel it will again look for a valid time signal Every 10 minutes a Digital Clock Timer will activate the receiver and starting with the stored channel it will again look for a valid time signal If necessary the clocks will resynchronize to the correct time If an Analog clock has not decoded a valid time signal for a pre determined number of days it will go to a step mode Low battery voltage is a common cause of the clock to not properly decod
20. SURANCE A Qualifications 1 Comply with Wisconsin Commercial Building Codes International Building Code IBC 2 Manufacturer Qualifications ISO 9001 2000 registered and a minimum of five years experience in producing doors of the type specified 3 Installer Qualifications Manufacturer s approval DELIVERY STORAGE AND HANDLING A Follow manufacturer s instructions WARRANTY A Standard Warranty Two years from date of shipment against defects in material and workmanship PART 2 PRODUCTS 2 1 2 2 MANUFACTURERS A Manufacturers Base on Cornell Iron Works Inc Model ESD 10 with face of wall mounted doors 1 Cornell Iron Works Inc 2 The Cookson Company 3 McKeon Door Company 4 Lawrence Roll Up Doors Inc 5 Overhead Door Corporation MATERIALS A Curtain 1 Slats No 5F 0 050 inch 1 270 mm aluminum 2 Bottom Bar Two 2x2x1 8 inch 50x50x3 2 mm aluminum angles 3 Fabricate interlocking sections with high strength cast iron endlocks on alternate slats each secured with two 14 6 35 mm rivets Provide windlocks as required to meet specified wind load 4 Slat Finish a Aluminum Clear anodized 5 Bottom Bar Finish a Aluminum Clear anodized B Guides Fabricate with aluminum angles Provide windlock bars of same material when windlocks are required to meet specified wind load Top of inner and outer guide angles to be flared outwards to form bell mouth for smooth entry of curtain i
21. ale 3 P 0 10 Scale 3 P 0 1 A8 2 2015 Bray Associates Architects Inc 2014 Bray Associates Architects Inc TOS CAF RF 121 0 OFFSET VENT PIPING IN CABINET SPACE AS SHOWN TOS 2nd FLR 114 2 1 2 OFFSET SANITARY PIPING IN CEILING SPACE OF FIRST NOTE TYPICAL SINK FLOOR AS SHOWN INSTALLATION AT ALL AREAS WITH BEAM CONFLICTS TYP SINK PIPING DETAIL AT BEAM 1 4 2 1 0 Wiwaukas Project Title Issue Dates Project Number 215 North Water Street 7 30 2015 mg Suite 250 31 64 uite 2 bray _ mivauee wiss202 Black River Falls Elementary School CI soami waa rarezz6ne0 Black River Falls School District AD2 P1 F 414 226 0224 www brayarch com 410 County Road A Black River Falls WI 2014 Bray Associates Architects Inc SPRINKLER HEAD SCHEDULE SYMBOL TYPE FINISH DESCRIPTION CONCEALER SEE NOTE 2 CONCEALED TYPE SPRINKLER HEAD WITH PENDANT QUICK RESPONSE PENDANT TYPE SPRINKLER HEAD RECESSED DRY TYPE SPRINKLER HEAD LOCATED IN FREEZER AND COOLER PENDANT QUICK RESPONSE PENDANT TYPE SPRINKLER HEAD ALL HEADS SHALL BE PROVIDED WITH METAL PROTECTORS SIDEWALL CHROME Ni CHROME SIDEWALL SPRINKLER HEAD WITH ESCUTCHEON FOR ELEVATOR SHAFT KEYED NOTE SYMBOL INDICATES TYPE OF SPRINKLER HEAD TO BE LOCATED IN THE
22. cks will continue to function as accurate quartz clocks until a valid time signal is decoded If signal transmission is not restored after 48 hours the second hand will five step as a visual indicator that the signal has been lost Should the clocks lose power and signal the clocks will not function Clock locations shall be as indicated and clocks shall be fully portable capable of being relocated at any time U S only System must operate in accordance with a Radio Station Authorization Form FCC 601 LM granted by the Federal Communications Commission FCC This license will be issued to and held by the end user Automated Bell Scheduling System Description 1 The Automated Bell Scheduling System uses a wired Ethernet network connection for synchronization data collection alerting scheduling data backup and user access from anywhere in the world The Automated Bell Scheduling System can be scaled from a single building to a network of buildings or an enterprise spread across many time zones providing traceable accuracy data and performance System devices are synchronized by signals from the system s network platform over an Ethernet The Automated Bell Scheduling System incorporates automated device monitoring alerting and reporting firmware The Automated Bell Scheduling System can be programmed to email alerts to assigned staff of device status conditions including escalation notifications 3164 28
23. d 2 1 2 to all adjacent dimension North West of the grid line Subtract 2 7 to all adjacent dimension South East of the grid line Near the North East corner of the elevator Change the joist seat depth dimension from 2 to 2 5 8 At the South West wall of the elevator Add the lintel mark L 02 Near column grid AL A5 Add a roof drain RD and frame Near column grid AL A9 Add a roof drain RD and frame Between columns at grid lines AD A24 AG A24 and AK A24 Add two grits HSS8x4x1 4 122 8 At column grid lines AN A15 1 and AG A15 1 Change the top of steel elevation from 124 4 to 124 0 8 At column grid lines BL B3 Change top of steel elevation from 128 5 7 to 128 8 9 At column grid lines AF A4 Omit Section mark 5 S5 4 10 At column grid lines AE A7 Add Section mark 5 S5 4 11 Near column grid lines AG A3 Add the Elevation mark S4 1 12 Steel Lintel Schedule Add the Mark L 02 Type A Size W8x10 PL REINF 14 x7 13 Non Load Bearing Masonry Lintel Schedule Add the schedule refer to the revised sheet S1 8 Sheet S1 9 Enlarged Roof Framing Plan Area B 1 Atthe North East exterior wall of the Gym Change the section mark 1 S5 14 to 5 S5 13 2 Near column grid BD B15 Change the elevation 128 11 3 16 to 128 11 1 8 3 Near column grid BK B23 Change the elevations 129 2 3 8 to 129 2 5 8 4 Near column grid BM B15 Change the elevation 128711 9 16 to 1
24. del Internal antennal 46 0 L 116 8cm Weight 7Ibs Internal Antenna Model only Transmitter shall transmit time continuously to all clocks in the system 20 21 22 23 3164 28 33 23 6 BUILDING PACKAGE ADDENDUM 2 Internal clock Transmitter shall contain an internal clock such that failure to update time from source will not disable the operation of the clocks Transmitter shall include a surge suppressor battery backup and a mounting shelf Transmitter shall have the following switches a Time zone adjustment switches for all time zones in the world Includes Eastern Central Mountain Pacific Alaska and Hawaii b Switch to allow the following configuration Daylight Saving Time bypass option 12 hour or 24 hour display GPS or NTP time source Local or LAN configuration UTC or UTC 30 minute UTC offset option CANADA for Newfoundland Transmitter housing shall incorporate a display which shall include the following Time readout AM and PM indicator if 12 hour time display is set Day and date readout Time zone indicator including Standard or Daylight Savings Time On screen menu to verify diagnostics errors time updates and switch settings toggled by sequence of push buttons next to display Status LEDs The LED signal indicator consists of three visual LEDs that indicate the status of the transmitter The green LED indicates one of the three statuses including 1 solid green transmitter is tra
25. e a time signal If a clock goes into step mode replace the batteries first and then determine if the clock synchronizes to master time source before attempting other troubleshooting methods If a Digital Clock Timer has not decoded a valid time signal for a pre determined number of days the display colon indicator will flash continuously until a valid time signal is received General The clock system shall include a transmitter NTP time source analog clocks digital clocks network bell relay and accessories 1 Watt Transmitter 17 18 Transmitter with a surge suppressor battery backup and a mounting shelf Unit shall obtain current atomic time from NTP time source The clock system shall transmit time continuously to all clocks in the system Transmission Frequency Ranges 72 020 to 72 980 MHz Maximum Transmission 1 watt 30dBm maximum at transmitter Radio Technology Narrowband FM Channel Bandwidth 20 kHz maximum Transition Mode One way communication Data Rate 2 KBps Operating Range 32 F 122 F 0 50 C Transmitter output power 26 to 30 dBm Frequency Deviation 4 kHz Power 120 VAC 60 Hz Internal Power 5 VDC Carrier Frequency Stability 20 ppm Housing Enclosure Transmitter housing shall be black metal case 16 W x 1 7 8 H x 12 D 40 64cm W x 4 52cm Hx 30 48cm D Power Supply Power supply included a Input 120 volt AC 50 60 Hz 0 6 amps b Output 9 volt DC Internal Antenna Mo
26. ear extended clock warranty Manufacturer offers an extended warranty on system devices The supporting devices and labor for installation shall be warranted for a period of not less than 1 year from the date of commissioning against defects in materials and workmanship The warranty shall be comprehensive No deductibles shall be allowed for travel time service hours and repair parts cost G During the guarantee period there shall be no charges to the Owner for service calls for guarantee work However when service work is required to repair items damaged by neglect misuse or vandalism costs shall be reimbursed to this Contractor H The warranty shall not deprive the Owner of other rights the Owner may have under other provisions of the Contract Documents and will be in addition to and run concurrent with other warranties made by the Contractor under the requirements of the Contract Documents moOw a PART 2 PRODUCTS 2 1 MANUFACTURER A Wireless clock system shall be manufactured by 1 Primex Wireless Inc Bill Matenaer 965 Wells Street Lake Geneva WI 53147 Phone 800 537 0464 Mobile 262 745 6770 bmatenaer primexinc com B Alternate wireless clock system manufacturer 1 American Time Jeff Bergeson 140 3rd Street South P O Box 707 Dassel MN 55325 Phone 877 213 0642 Mobile 763 242 5825 jbergeson atsclock com 2 2 SEQUENCE OF OPERATION A Transmitter Operation 2 3 C EQUIPM
27. edule REVISE A118A Elevator Wall Finish to be PLAM 2 2 Inthe Material ID Schedule under material category Paint Sherwin Williams ADD PT 9 TO MATCH EXTERIOR BRICK COLOR 3 ADD General Note to read 1 All exposed columns to be painted color of adjacent wall unless noted otherwise Sheet A9 1 First Floor Finish Plan Unit A 1 CLARIFICATION added dimensions and notes for flooring pattern see attached revised sheet A9 1 Sheet A9 2 First Floor Finish Plan Unit B 1 REVISED flooring pattern and added dimensions and notes for flooring pattern see attached revised sheet A9 2 Sheet A9 3 Second Floor Finish Plan Unit A 1 REVISED flooring pattern and added dimensions and notes for flooring pattern see attached revised sheet A9 3 Sheet A9 4 Second Floor Finish Plan Unit B 1 REVISED flooring pattern and added dimensions and notes for flooring pattern see attached revised sheet A9 4 abo 173 N BROADWAY G MILWAUKEE WI 53202 o PHONE 414 226 0200 www brayarch com 3164 Black River Falls Elementary School Addendum 2 Page 7 BUILDING PACKAGE FOOD SERVICE FES 1 0 Food Service Equipment Plan 1 REVISED soiled dish table configuration 2 OMIT item 33 FS 2 0 Plumbing Equipment Plan 1 REVISED soiled dish table configuration FS 3 0 Electrical Equipment Plan 1 REVISED soiled dish table configuration FS 4 0 Wall Backing Plan 1 REVISED soiled dish table c
28. f system software methods for modifying default settings adding or deleting system devices and modifying settings for system monitoring and testing Demonstrate maintenance procedures for system devices END OF SECTION 28 33 23 solid foundation forward thinking SOLID SURFACE SSF 1 410 County Road A Black River Falls WI o o c o c gt _ x fom D D LLI 2 Lic D a a sc o Ko m Black River Falls School District A6 8 PLAM 1 u aS Pal FINISHED PLASTIC gt a LAMINATE END L 4 FINISHED PLASTIC 2 PANEL PLAN2 BNG L LAMINATE END OPEN KNEE SPACE OPEN KNEE SPACE PANEL PLAM 2 SEE SECTION FOR SEE SECTION FOR Issue Dates SUPPORT BRACKET SUPPORT BRACKET 7 30 2015 DETAL S DETAIL ZA 542015 Addendum 2 1 6 H DRAWER UNIT D A218 LMC CIRCULATION DESK WEST DRAWER UNIT Scale 1 2 1 0 INTERIOR ELEVATIONS Sheet Title Project Number 3164 Sheet Number 1 A7 4 2015 Bray Associates Architects Inc 3 5 8 METAL STUD DIAGONAL BRACING 35 8 METAL STUD 4 0 O C AN DIAGONAL BRACING A SEE PLAN 5 4 0 O C SEE PLAN FINISHED CEILING SEE ROLL UP DOOR FINISHED CEILING SEE 8 REFLECTED CEILING
29. hange the top horizontal column GRID mark to AD 4 Detail 14 S0 4 Change the title from CP 12 PIER DETAIL TO CP 14 PIER DETAIL Change the vertical column GRID mark to A15 1 Change the bottom horizontal column GRID mark from AV to AU Sheet 1 4 Enlarged Foundation Plan Area A 1 Move column grid A18 0 2 72 South East Add 2 1 to all adjacent dimensions North West of the grid line Subtract 2 7 to all adjacent dimensions South East of the grid line At column grid AL A14 Add the plan detail mark 11 A0 4 At column grid AT A15 1 Add the word SIMILAR to the plan detail mark 3 S0 4 At column grid AV A15 1 Add the word SIMILAR to the plan detail mark 4 S0 4 Concrete Pier Schedule Change the note TOP OF CONC PIER ELEVATION 99 8 UNO to TOP OF CONC PIER ELEVATION 99 4 UNO At Stair S102 Add concrete platform Add Section mark 18 S5 1 Change Section marks 3 S5 10 to 3 S5 10 SIM Add the words RAISED CONCRETE PLATFORM SEE DTL AND ARCH Sheet 1 5 Enlarged Foundation Plan Area B 1 Atthe North East exterior wall of the Gym Change the section mark 1 S5 14 to 5 S5 13 2 Concrete Pier Schedule Change the note TOP OF CONC PIER ELEVATION 99 8 UNO to TOP OF CONC PIER ELEVATION 99 4 UNO Sheet 1 6 Enlarged Second Floor Framing Plan Area A 1 Move column grid A18 0 2 1 2 to the South East Add 2 72 to all adjacent dimension North West of the grid line Subtract 2 7 to all adjacent dimen
30. icense 6 Plug power supply into electrical outlet 7 Transmitter will be located in Data B217 F Analog Clocks 1 Furnish all equipment necessary for a complete and operational system 2 Perform the following operations with each clock a Configure and set clock to correct time in accordance with manufacturer instructions b Observe clock until valid signals are received and clock adjusts itself to correct time Ci Install each clock per its model mounting specifications per manufacturer instructions and mounting instructions at the indicated location G Digital Clocks 1 Furnish all equipment necessary for a complete and operational system 2 Perform the following operations with each clock a Set time zone time date option and brightness level in accordance with manufacturer instructions and per owner requirements b Observe clock until valid signals are received and clock adjusts itself to correct time C Install each clock per its model mounting specifications per manufacturer instructions and mounting instructions at the indicated location H Wire guards Secure to wall using approved theft resistant fasteners I Field Inspection 1 Inspection Make observations to verify that system devices and components are properly labeled 3 5 3164 28 33 23 10 BUILDING PACKAGE ADDENDUM 2 2 Prior to final acceptance inspect each system device and component adjust as required and replace parts which are found defecti
31. ifications A firm or individual experienced in installing erecting or assembling work similar in material design and extent to that indicated for this Project whose work has resulted in construction with a record of successful in service performance 4 Manufacturer s Field Services Where indicated engage a factory authorized service representative to inspect field assembled components and equipment installation Report results in writing 3164 28 33 23 4 BUILDING PACKAGE ADDENDUM 2 5 Manufacturer must carry replacement parts Permits Obtain operating license for the transmitter from the FCC C Regulatory Requirements ja Equipment and components furnished shall be of manufacturer s latest model 2 Transmitter and receiver shall comply with Part 90 of FCC rules as follows a This device may not cause harmful interference and b This device must accept interference received including interference that may cause undesired operation c Transmitter frequency shall be governed by FCC Part 90 35 d Transmitter output power shall be governed by FCC Part 90 257 b 3 System shall be installed in compliance with local and state authorities having jurisdiction 1 8 WARRANTY gt Manufacturer will provide a one year warranty on transmitter All other devices and components will have a 1 year warranty Manufacturer offers a two three or five year extended transmitter warranty Manufacturer offers a five y
32. ions 1 In details 8 9 amp 10 A7 4 REVISE notes reading 1 2 REVEAL PLAM 3 INSET as 1 2 EXTRUDED ALUMINUM CHANNEL and REVISE notes reading 1 2 REVEAL as 1 2 EXTRUDED ALUMINUM CHANNEL 2 CLARIFICATION added dimensions in detail 11 A7 4 see attached revised sheet 1 A7 4 Sheet A8 0 Door Schedule Door 8 Frame Types 1 In Door Schedule for door B111b REVISE DOOR HEIGHT to be 7 10 and REVISE FRAME FINISH to be PT 9 Under COMMENTS ADD DOOR TO BE PAINTED PT 9 2 In Door Schedule for door B111c REVISE FRAME FINISH to be PT 9 Under COMMENTS ADD DOOR TO BE PAINTED PT 9 In Door Schedule for door B221a REVISE HARDWARE GROUP to be 31 OMIT detail 4 A8 0 Under Door Types REVISE DOOR TYPE R STEEL COILING DOOR as DOOR TYPE R ALUMINUM COILING DOOR 6 Under Door Types REVISE DOOR TYPE R and DOOR TYPE C note ROLL UP DOOR HOOD as ROLL UP DOOR MOUNTED ABOVE SOFFIT SEE RCP 8 DETAIL Sheet A8 2 Door Details 1 REVISED details 9 amp 10 A8 2 to reflect soffit at overhead coiling door and shutter locations see attached revised sheet 1 A8 2 Sheet A8 3 Curtain Wall Types 1 In 13 A8 3 CW 13 REVISE note 2 1 2 WIDE x 8 7 8 DEEP FRAME as 2 1 2 WIDE x 10 1 8 DEEP FRAME Sheet A9 0 Room Finish Schedule amp Material ID 1 In the Room Finish Sch
33. m 1 Page 5 under section 2 2 A 1 ADD item c to read as follows c Mule Hide Product Co Inc Section 08 31 16 Access Door and Frames 1 Page 2 in section 2 2 A 3 ADD items and m to read as follows 18 x 18 door size M 18 1 8 x 18 1 8 opening size Section 08 33 25 Coiling Service Doors 1 ADD specification section 08 33 25 COILING SERVICE DOORS Section 08 71 00 Finish Hardware 1 Page 6 in section 2 2 A OMIT item 2 2 Page 8 in section 2 10 N ADD Dorma as an approved manufacturer Section 09 29 00 Gypsum Board Assemblies 1 Page 12 in section 3 7 E REVISE item 11 read as follows 11 Textured Finish Apply USG Light Sand Texture Provide samples for approval Section 09 53 23 Modular Metal Ceiling System 1 Page2 in section 2 1 A 1 ADD items c read as follows c Gordon Inc 3164 Black River Falls Elementary School Addendum 2 Page 2 BUILDING PACKAGE Section 09 68 16 Carpet 1 Page 4 in section 2 1 E REVISE item 2 to read as follows 2 Tile Size 1 m x 1 m 39 4 x 39 4 Section 09 84 33 Sound Absorbing and Tackable Wall Panels 1 Page2 in section 2 1 A 1 ADD items p and q to read as follows p Lamvin Inc q MBI Products 2 Page 2 in section 2 1 B 1 ADD items p and q to read as follows p Lamvin Inc q MBI Products Section 09 84 35 Sound Reflecting Treatment 1 Page 2 in section 2 1 A ADD ite
34. ms 9 to read as follows 9 MBI Products Section 10 14 02 Exterior Cast Aluminum Signage 1 Page2 in section 2 3 REVISE item A to read as follows A BLACK RIVER FALLS ELEMENTARY 12 letters Section 10 28 00 Toilet Accessories 1 Page 2 in section 2 4 K REVISE Toilet Room Accessory Schedule Mark M as Toilet Room Accessory Schedule Mark S Section 11 40 00 Food Service Equipment 1 Page 2 in section 2 0 OMIT item 33 Section 11 66 26 Safety Wall Pads 1 DELETE Specification Section 11 66 26 SAFETY WALL PADS in its entirety and ADD the new Specification Section 11 66 26 SAFETY WALL PADS issued with this addendum Section 23 09 00 Building Automation System for HVAC 1 Page 2 in section 2 1 VARIABLE FREQUENCY DRIVES ADD the following acceptable manufacturers to paragraph 2 1 J Trane Tracer SC installed by Trane Company Section 28 33 23 Wireless Clock System 1 DELETE Specification Section 28 33 23 WIRELESS CLOCK SYSTEM in its entirety and ADD the new Specification Section 28 33 23 WIRELESS CLOCK SYSTEM issued with this addendum Section 32 31 21 Aluminum Louver Gates 1 Page 2 in section 2 3 B REVISE item 2 to read as follows 2 5 square aluminum corner post 2 Page 2 in section 2 3 B 3 REVISE Nominal Opening Size 8 wide by 8 0 high as Nominal Opening Size 9 wide by 8 0 high
35. nsmitting 2 not illuminated transmitter has not received an initial time signal after power up and or reset and 3 flashing transmitter is not broadcasting due to standby mode or there is a condition that is causing the transmitter not to broadcast properly The yellow LED indicates one of the two statuses including 1 not illuminated no warning conditions 2 flashing transmitter has not received a time update for 48 hours or a 1PPS one pulse per second has not been detected within the last 48 hours The red LED indicates one status 1 solid red defined error condition exists Primex model XRO1IM papgp fan NTP Time Source 1 2 Transmitter will allow for NTP time input Unit shall obtain current time from NTP through a hardwired Ethernet port Analog Clocks O A LIN ha ed Clocks shall be wall mounted 12 5 Traditional series round clock Face shall be white Frame shall be black Hour and minute hands shall be black Clock frames and lenses are of durable thermoplastic Clocks shall have a tamper proof theft resistant clock lock mounting slots Clocks shall be capable of automatically adjusting for Daylight Saving Time Time shall be automatically updated from the transmitter 6 times per day If the transmitter stops transmitting valid time signals due to power failure the clocks will continue to function as accurate quartz clocks until a valid time signal is decoded If signal transmission is not resto
36. nto guides Provide removable guide stoppers to prevent over travel of curtain and bottom bar 3164 08 33 25 3 BUILDING PACKAGE ADDENDUM 2 1 Finish a Aluminum Clear anodized Counterbalance Shaft Assembly 1 Barrel Steel pipe capable of supporting curtain load with maximum deflection of 0 03 inches per foot 2 5 mm per meter of width 2 Spring Balance Oil tempered heat treated steel helical torsion spring assembly designed for proper balance of door to ensure that maximum effort to operate will not exceed 25 Ibs 110 N Provide wheel for applying and adjusting spring torque Brackets Fabricate from minimum 3 16 inch 5 mm steel plate with permanently lubricated ball or roller bearings at rotating support points to support counterbalance shaft assembly and form end closures 1 Finish a Phosphate treatment followed by baked on polyester powder coat color as selected by Architect from manufacturer s standard color range minimum 32 colors minimum 2 5 mils 0 065 mm cured film thickness ASTM D 3363 pencil hardness H or better Sensing Edge 1 Bottom Bar Replaceable 3 point compressible vinyl gasket extending into guides 2 Bottom Bar Motor Operated Doors Sensing edge within neoprene or rubber astragal extending full width of door bottom bar 2 3 ACCESSORIES A Operator and Bracket Mechanism Cover Provide 0 040 inch 1 016 mm aluminum sheet metal cover to enclose exposed moving operating componen
37. onfiguration 2 OMIT wall backing where shown on revised plan FS 5 1 Elevation Plan 1 REVISED soiled dish table configuration 2 OMIT item 33 FS 5 2 Elevation Plan 1 ADDED elevations for Sneeze Guard Buffet Counter Cash Stand Clean Dish Table and Soiled Dish Table 2 ADDED plan for Cooler Freezer with note for remote refrigeration located on roof PLUMBING Sheet P1 5 1 Add 2 roof drains and revise storm piping Reference drawing attached Sheet P1 7 1 Add 2 roof drains and revise size of adjacent roof drains Reference drawing attached Sheets P1 5 amp P 6 1 Clarification Added Sink piping detail to show pipe routing around beam at first floor ceiling Typical piping detail where beam conflict occurs Reference attached drawing AD2 P1 FIRE PROTECTION Sheet FP1 1 1 Revised sprinkler head 1 finish information and note 2 below schedule Reference attached drawing AD2 FP1 2 Revised sprinkler heads in Cafeteria to concealed heads symbol 1 heads to be installed in dropped ceiling panels Sheet FP1 2 1 Revised sprinkler heads in Kitchen areas with dropped ceilings to concealed heads symbol 1 2 Revised heads in Corridor 120 west of Vestibule 121 to concealed heads symbol 1 Sheet FP1 3 1 Revised heads in Corridor 220 to pendant heads symbol 2 Sheet FP1 4 1 Revised heads in Art Storage B222A to recessed heads symbol 1 2 Remove extra symbol 2 from SGI B2
38. p and maintenance instructions 4 Floor plans indicating the location of system transmitter s approved by manufacturer will be submitted to owner prior to installation 5 U S only Operating License Submit evidence of application for FCC Radio Station Authorization prior to installing equipment Furnish the license or a copy of the application for the license to the Owner End User prior to operating the equipment The original license must be delivered to the Owner End User OPERATION amp MAINTENANCE MANUALS A Submit Operations amp Maintenance Manuals in accordance with Section 26 05 04 B The following information shall be submitted in addition to the items listed above 1 Wiring diagram indicating wire size and type for each individual piece of equipment 2 Complete riser diagram indicating all equipment and interconnecting components with indication of location of each device 3 Provide copy of written warranty QUALITY ASSURANCE A Provide quality assurance in accordance with Section 26 05 04 B The following shall be provided in addition to items listed above 1 Arrange pre installation meeting with electrical contractor 2 Factory Authorized Service Representative Qualifications An authorized representative of manufacturer who is trained and approved by manufacturer to inspect installation of manufacturer s products that are similar in material design and extent to those indicated for this Project 3 Installer Qual
39. red after 96 hours the second hand will five step as a visual indicator that the signal has been lost Should the clocks lose power and signal the clocks will not function Analog clock receivers shall be as follows Receiver sensitivity gt 110 dBm Receiver power AC powered 120VAC Antenna type internal Antenna gain 7 dBd Clocks shall be electric AC powered 120 VAC model as specified in models specifications BOT 11 12 13 3164 28 33 23 7 BUILDING PACKAGE ADDENDUM 2 Electric AC models will include a cord with plug If power is interrupted the clock will stop until power resumes Upon resumption of power the clock will self correct to the current time Primex model 14306 Analog Clocks Gymnasium 1 Clocks shall be wall mounted 2 16 Traditional series round clock for use in Gymnasium only 3 Face shall be white Frame shall be black Hour and minute hands shall be black 4 Clock frames and lenses are of durable thermoplastic 5 Clocks shall have a tamper proof theft resistant clock lock mounting slots 6 Clocks shall be capable of automatically adjusting for Daylight Saving Time 7 Time shall be automatically updated from the transmitter 6 times per day 8 If the transmitter stops transmitting valid time signals due to power failure the clocks will continue to function as accurate quartz clocks until a valid time signal is decoded If signal transmission is not restored after 9
40. revised sheet A1 7 Sheet A1 8 Enlarged Stairs and Toilet Room Plans 1 REVISE drawing title and added callout for 11 A1 8 see attached revised sheet A1 8 2 ADDED double robe hook at CD TLT SHWR in 5 A1 8 see attached revised sheet A1 8 Sheet A3 2 Building Sections 1 REVISE drawing title for 3 A3 2 to read S101 STAIR SECTION 2 REVISE drawing title for 4 A3 2 to read S102 STAIR SECTION 3 REVISE drawing title for 5 A3 2 to read S103 STAIR SECTION Sheet A2 1 Exterior Elevations 1 Inthe Exterior Keynote Legend REVISE Keynote E17 to read as follows METAL BUILDING SIGNAGE FONT ARIAL BLACK RIVER FALLS ELEMENTARY 12 HIGH LETTERS Sheet A2 2 Exterior Elevations 1 Inthe Exterior Keynote Legend REVISE Keynote E17 to read as follows METAL BUILDING SIGNAGE FONT ARIAL BLACK RIVER FALLS ELEMENTARY 12 HIGH LETTERS Sheet A5 1 RCP First Floor Unit A 1 ADDED soffits at overhead coiling shutter and door with access panels for motors at locations in Servery A119A and Kitchen A119B see attached revised sheet A5 1 2 REVISED lay in ceiling spacing and lighting locations in the Servery A119A and Kitchen A119B see attached revised sheet A5 1 Sheet A6 6 Interior Details 1 CLARIFICATION added notes for sealant and or paint in details 2 3 6 amp 7 A6 6 see attached revised sheet A6 6 2 REVISED detail 11 A6 6 see attached revised
41. sion South East of the grid line Near column grid lines AK A17 Change the beam spacing dimensions from 7 2 1 2 to 7 3 3 2 and 5 8 5 8 to 5 6 1 8 2 Atthe South East wall of the elevator Add the lintel mark L 02 3 Steel Lintel Schedule Add the Mark L 02 Type A Size W8x10 PL REINF 14 x7 4 Non Load Bearing Masonry Lintel Schedule Add the schedule refer to the revised sheet 1 6 5 Atthe Stair S102 Change the stair landing joist size for C4x4 5 to C6x8 2 6 Atthe StairS101 Respace the C5x6 7 joist as shown on the addendum drawings Sheet 1 7 Enlarged Second Floor Framing Plan Area B 1 Add all line work relating to steel beams and steel girders Refer to the revised sheet 1 7 akon gt 173 N BROADWAY G MILWAUKEE WI 53202 o PHONE 414 226 0200 www brayarch com 3164 Black River Falls Elementary School Addendum 2 Page 4 BUILDING PACKAGE 2 Near column grid lines BE B18 Change the section mark 6 S5 4 to 15 S5 2 3 Near column grid lines BH B18 Change the section mark 5 S5 4 to 16 S5 2 4 At Stair S103 Respace the C5x6 7 joist as shown on the addendum drawings Add the header size C12x20 7 5 Steel Lintel Schedule Add the Mark L 02 Type A Size W8x10 PL REINF 14 x7 6 Non Load Bearing Masonry Lintel Schedule Add the schedule refer to the revised sheet 1 7 Sheet 1 8 Enlarged Roof Framing Plan Area A 1 Move column grid A18 0 2 1 2 to the South East Ad
42. try Association TIA EIA D Compliant with limits for Federal Communication Commission FCC Class B device E Conform to current National Electrical Manufacturers Associates NEMA Standards F The system should meet or exceed the technical standards set forth in FCC rules part 76 G Primex Wireless Time System User Manual DESCRIPTION OF WORK A Furnish and install a complete and operable new synchronized wireless clock system using the Primex Wireless XR Time Synchronization System as indicated on the drawings and as specified herein B Furnish and install a Primex SNS Automated Bell Scheduling System with network bell relay switch and software for bell scheduling to be synchronized with the wireless clock system as specified herein C Furnish and install all head end equipment and all field equipment Furnish and install all low voltage cabling required for a complete and operating system D All bids shall be based on the equipment as specified herein The basis of design for this system is Primex Wireless Inc An American Time SiteSync IQ wireless clock system and a wired tone generator is an approved alternate product for use on this project Alternate clock system shall be equal to the specified system herein E Transmission Systems 1 NTP Time Source 2 72MHz Transmitter F Clocks 1 Analog 120V 2 Digital 120V G Automated Bell Scheduling System H Definitions 1 NTP Network Time Protocol used for synchronizing
43. ts at coil area of unit Finish to match door 2 4 OPERATION A Supply Model GH heavy duty cUL listed gear head hoist type operator s rated 3 4H P 120Volts Single Phase Provide cUL listed electric door operator assembly of size and capacity recommended by door manufacturer complete with electric motor and factory pre wired motor controls worm gear reduction unit solenoid operated brake 3 button OPEN CLOSE STOP control station Motor shall be high starting torque continuous duty industrial type protected against overload by a current sensing or thermal overload device Speed reduction shall be worm gear in oil bath gear reducer with synthetic All Climate oil Shall provide 45 1 speed reduction Door drive shall utilize minimum 50 roller chain and sprockets Operator shall be equipped with an electrically interlocked floor level disconnect and chain hoist for manual operation and an electric solenoid actuated brake to stop the motor and hold the door in position Operator shall be capable of driving the door at a speed of 8 to 9 inches per second 20 to 23 cm sec Fully adjustable driven linear type limit switch mechanism shall synchronize the operator with the door Low friction nylon limit nuts fitted on threaded steel shaft rotating on oilite self lubricating bronze bushings The motor shall be removable without affecting the limit switch settings 1 Control Station Flush mounted Open Close key switch with Stop push b
44. uts 0 12V configurable pullups c 4 universal inputs analog 0 5 10V or digital 0 12V with configurable pullups d 4 digital outputs open collector 24V 0 1A 3 Serial Interface a 600 19200 Baud 7 8 bit Odd Even No par 4 Network Interface a RJ45 10 100 Mbit Ethernet Autodetect b TCP IP UDP DHCP Modbus TCP SNMP c HTTP web server for control status and configuration 5 Power Input a 12 24 VDC 20 6 Certifications a FCC A and B CE A and B 7 Primex model SNSBRL105 PART 3 EXECUTION 3 1 EXAMINATION A Examine conditions with the installer present for compliance with requirements and other conditions affecting the performance of the system and system devices B Do not proceed until unsatisfactory conditions have been corrected GC Verify that construction is complete in spaces to receive equipment and that rooms are clean and dry D Verify that 120 volt electrical outlet is located within 6 feet 1 83m of location of transmitter and the outlet is operational and properly grounded E AC powered devices Verify that electrical power outlet is near location of clock or timer and the outlet is operational and properly grounded F Verify that construction is complete in spaces to receive equipment and that rooms are clean and dry 3 2 FIELD MEASUREMENTS A Field verify all measurements Do not base on contract drawings 3 3 3 4 B C D 3164 28 33 23 9 BUILDING PACKAGE ADDENDUM 2 Identify
45. utton NEMA IB Sensing Edge Provide automatic reversing control by an automatic sensing switch within neoprene or rubber astragal extending full width of door bottom bar 3164 08 33 25 4 BUILDING PACKAGE ADDENDUM 2 1 Provide an electric sensing edge device Contact before door fully closes shall cause door to immediately stop downward travel and reverse direction to the fully opened position Provide a self monitoring wireless sensing edge connection to motor operator eliminating the need for a physical traveling electric cord connection between bottom bar sensing edge device and motor operator Supervised system alters normal door operation preventing damage injury or death due to an inoperable sensing edge system PART 3 EXECUTION 3 1 3 2 3 3 3 4 3 5 EXAMINATION A Examine substrates upon which work will be installed and verify conditions are in accordance with approved shop drawings B Coordinate with responsible entity to perform corrective work on unsatisfactory substrates C Commencement of work by installer is acceptance of substrate INSTALLATION A General Install door and operating equipment with necessary hardware anchors inserts hangers and supports B Follow manufacturer s installation instructions ADJUSTING A Following completion of installation including related work by others lubricate test and adjust doors for ease of operation free from warp twist or distortion CLEANING
46. ve Manufacturer Services Installation and user guides shall be provided 2 Commissioning General Provide manufacturer system commissioning in accordance with manufacturer written recommendations Perform operational testing to verify compliance with requirements Adjust as required 3 Manufacturer to provide specified level of commissioning services 4 On site commissioning system deployment training including system set up device preconfiguration system functionality verification of device network connections and device installation training System Startup 1 At completion of installation and prior to final acceptance turn on the equipment ensure that all equipment is operating properly and that all system devices clocks and components are functioning Adjusting 1 Prior to final acceptance inspect each clock adjust as required and replace parts which are found defective Testing 1 All system devices must be tested at their operational location under normal operational conditions Cleaning 1 Prior to final acceptance clean exposed surfaces of devices using cleaning methods recommended by manufacturer 2 Remove temporary labels from clock faces Do not remove labels from backs of clocks Protection 1 Protect finished installation until final acceptance of the project OWNER TRAINING Provide demonstration and training for owner facility staff in administering system Demonstrate monitoring o

Download Pdf Manuals

image

Related Search

Related Contents

Note de service  Cuecehuevos Egg Central® CEC-10 INSTRUCCIONES & LIBRO  English 1 For Your Safety: Read this user guide carefully to  MANUAL 9V Pag-novo logo.cdr  OmniMount LEDW60 flat panel wall mount  Samsung WD7101CKW Felhasználói kézikönyv  Marantz PM-15S1 User's Manual  Samsung SCX-6122FN Керівництво користувача  Jabra BIZ™ 2400 USB - Telefonanlage Shop  ZTE MF28D user manual - 4G  