1. The bottom margin User Manual OuantorDentVet TM 806 EN 12 5 3 Overlay Contents This selects items to show in the image when printing 12 6 System 12 6 1 File Management Data path This sets the destination folder where images Installation are stored Folder Database Data space This allocates disk space for saving images 30GB Auto deletion is activated when the allocated disk space becomes full Auto Deletion This sets whether to use Auto Deletion and Enabled Auto Deletion intervals When the user does 60 sec not take any action and the auto deletion interval is exceeded auto deletion starts Delete studies that are This defines the action to take when deleting Never delete not sent an image that has not been transmitted Never delete Check before deletion Always delete 12 6 2 System Options They are other system options Temporary File This sets a folder to save temporary files used in the Installation Path program Folder Temp Virtual This defines whether to use the Windows virtual Disabled Keyboard keyboard when entering data in the screen Enabled User Manual OuantorDentVet TM 806 EN 12 6 3 Date Date format This sets the date display format You can choose one YYYY MM DD of following three formats YYYY MM DD DD MM YYYY MM DD YYYY Separator This selects a separator for year month and day Choose one from following three 12 6 4 Dental
2. About this software Checks the current software version Exit Exits the program User Manual OuantorDentVet TM 806 EN 5 Create New Study 5 1 Screen Layout The New Study screen is the first page to start a scan Enter necessary patient and study information You can easily go to the next input field by using the Tab key Fields marked with are mandatory fields that must be filled in Name Species Owner Ref Physician Accession No i O e Z Figure 5 1 Create New Study Emergency scan Automatically fill in all the mandatory fields Used in a case of emergency where patient information has not been identified or when scanning needs to be performed first and the patient information will be entered later Edit Input Field It displays the Edit Input Field dialog box In the Edit Input Field dialog box you can change the order of input fields or add or delete input fields 3 System Menu Displays the system menu 4 Input Field Table 5 1 provides the input information User Manual OuantorDentVet TM 806 EN Table 5 1 Input Field Enter the patient s name Io Enter the patient ID Enter the patient s date of birth You can select a date from the drop down box or manually enter numbers When you enter a date of birth only without an age the age is calculated automatically Select the patient s sex You can choose one of Male Female NA Male Sterile Female Sterile or Sterile
3. Enter the patient s age Leave the Year field blank if the patient is less than 1 year old When you enter age only without a date of birth the date of birth are calculated automatically In that case month and day will be designated as January 1 Ref Phy Enter the ref physician s name Enter study information Enter the accession number If it is not entered although it is a Accession No i i i i mandatory field a random number is automatically assigned Enter the patient species You can choose either Canine or Specie Feline Enter the patient breed Enter the guardian information 5 Next Previous Page Move between pages 6 Next Go to the next screen of site selection User Manual OuantorDentVet TM 806 EN 5 2 Edit Column Dialog Box In the Input Field Edit dialog box you can change the order of the input fields and add or remove input fields They can be adjusted depending on your environment However mandatory input fields cannot be removed Birth Species Breed Ref Physician Figure 5 2 Edit Input Fields Lists input fields that will appear on the screen O Lists input fields that will not appear on the screen Moves the selected fields to the left or right Fields moved to the left will appear on the screen and those moved to the right will not appear The buttons are used to move between pages Moves the selected field upward or down to change the order Saves ch
4. Workstation Enter the workstation name name User Manual OuantorDentVet TM 806 EN Appendix A Canine Dental Chart Appendix B Feline Dental Chart NEE 21202 203 204 ES Appendix C Template
5. Dental and process image acquisition Figure 3 6 Scan Screen 3 8 Review You can search existing images in the Review screen It is useful for diagnosis after acquiring the images i Figure 3 7 Review Screen User Manual OuantorDentVet TM 806 EN 4 Home Screen 4 1 Screen Layout The Home screen is the first screen that appears when the program is run From the Home screen you can create a new study or view existing studies You can go to the Home screen by Clicking the Home button in the Navigation Bar Clicking the Study Exit button in the Scan screen or Clicking the Study Exit button in the Review screen Scan Review Figure 4 1 Home Screen Model name Displays the model name of QuantorDent Current time Displays current time in hours and minutes System Displays the System menu Create New Study Displays the New Study screen Ad HO Study List Displays the Study List screen User Manual OuantorDentVet TM 806 EN 4 2 System menu The System button is always displayed in the upper right corner of the program When you click the button the following menu appears on the screen Figure 4 2 System menu Settings Displays a setting dialog box IP calibration Runs IP calibration program Scanner control Runs scanner control program Check update Checks new version Checks for a new version If a new version is available it is automatically downloaded and installed
6. ER EE EE OE OE EE ERE 64 OR TROVE EE ae N EE N N 65 12 2 e CC EE 65 AE LG di EE N EE EE EE 65 12 33 DICOM ln 65 12 4 Network Export 66 12 4 1 Image Seer eee 66 User Manual QuantorDentVet TM BOG EN 12 42 ODUON eege 67 ON OCCT AY EE EE EO RreEErer 67 US MaK OE EE EE OE ER EE EGEDE SEERE 67 12 5 2 Auto Marking Margin esse eee 67 12 5 3 Overlay e lt en C 68 126 Le Te oe OE EENEN OEE EEEE 68 126 lk File Manageme his ei n ie Di ee be ie od oe ee on Ga oe N SRER 68 126 2 System Options AE EE EE OE OE KO IE OE N ke 68 126 DiE eege 69 ACTED E ii SE E E EEE A E EAE A A EE E E AE EE E EA E E 69 User Manual OuantorDentVet TM 806 EN 1 Introduction QuantorDentVet is an IP reader for intraoral X ray imaging QuantorDentVet is used to scan and review intraoral X ray images When scanning an IP radiated with X ray FireCR Dental shows the preview image on the LCD screen and the image is saved in the built in memory storage Shortly after the end of scanning the IP is deleted and it can be used for the next imaging Images stored in the scanner are transferred to QuantorDentVet in the image workstation via network or USB The images are post processed through QuantorDentVet and saved in the database that allows searching in the future QuantorDentVet can transport the acquired images to the hospital image storage system using DICOM Send The scanner can be connected to the in hospital network or directly to
7. End point Minimum value Maximum value Average value Pixel value Pixel value of the current position when the mouse was clicked over the graph A od PA YS User Manual OuantorDentVet TM 806 EN 9 6 Marking 9 7 File e Open a general image file B WE 9 8 Tool Set a pixel size Scan a measuring tool with a determined length Select a scanned image and click the Pixel Gap Calibration button The following dialog box will be displayed on the screen Enter the actual length of the measuring tool Click on the start point of the measuring tool over the image and start dragging Release the mouse at the end point of the measuring tool to complete the calibration User Manual OuantorDentVet TM 806 EN 9 9 Apply Set the range in which image processing will be applied When comparing two images you can apply same filters to both windows for easier comparison Icon Action Active The last clicked image is the active image Active image is indicated with orange edges Select Multiple images can be selected by clicking images while holding the Ctrl key The selected image is shown with blue edges Study Image processing is applied to all images in the study that the active image belongs to All Image processing is applied to all images Image filters that can be used with Apply Range are as follows Zoom move rotate flip window User Manual OuantorDentVet TM 806 EN
8. a marking 3 Click a point on the image You can edit predefined markings in the Overlay Marking under Settings Direct input marking Click on the Marking button Select Direct Input 3 Click on a position where you want to add the marking and a text box appears Enter your text Click outside the text box when you are done User Manual OuantorDentVet TM 806 EN 7 4 Rotation Flip You can rotate or flip the image Rotate counter clockwise 90 degrees Rotate clockwise 90 degrees Horizontal flip Vertical flip 7 5 180 degree rotation Rotate the image 180 degrees 7 6 Auto Window Automatically adjusts the image brightness and contrast User Manual OuantorDentVet TM 806 EN 7 Reject In spite of poor quality of a scanned image Reject preserves the current image with a Reject marking without rescanning When you click the Reject button a Reject marking is added on the upper left corner of the image as shown in the Figure and a Reason text box appears Type in the reason for rejection and click outside the text box when you are done If you click the Reject button again Reject is inactivated M Canine TASK LIST 2014 01 16 Figure 7 3 Reject User Manual OuantorDentVet TM 806 EN 7 8 QA Image Adjustment This can adjust the LUT curve of the image Adjusting the image requires expert knowledge about images Adjusting the image without proper know
9. be affected Physical Security It is recommended that the user employs some method of physical security when dealing with the system to ensure that only authorized personnel have access to the product User Manual OuantorDentVet TM 806 EN There are several vulnerabilities a malicious user could exploit locally Some examples are Theft of equipment Local password cracking Installation of hardware key loggers User Manual OuantorDentVet TM 806 EN Table of Contents 1 Introduction cc ER EE ER EER Ee ek eek Ee ee ee eek eek nerne 10 Fela MalorFealleS es es Ee ee Ds ED Ee eg Da ie ie ed 11 2 OAO EE EE OE OE EE OOE EE EST 12 2 1 Installation Environment 12 2 1 1 Recommended Computer Environment 12 2 1 2 Minimum Computer Requirements ss ee ee RR ee ee AR RE Ee ee ee ee ee 12 2 2 Installation sesse EER EER EER EER EER ER EE RE ee EE RE Ee ee ee eek Ee ee Ee ee eke ee ee ee 13 2 2 1 Software Installation sese ee ee EE Ee ee EE ee ee RE ERE ee EE ee ee ee ee ee ee ee ee 13 ZO Cla ANNO EI EE 17 N ou EER EE EE EE EE N 17 EE 17 AC N Selde ei 1 EE OE EE N OR TE N N 18 2 4 FireCR Dental CalibraHON ee eee ee eee ER ER ER EE ek Ee ee ee ee 19 PA oep EISE en ce eee Emei 20 Se EE Sea f ee 20 2 4 3 Step 3 Scan LOW Dose eee 20 2 44 Step 4 Scan Mid Dose ie ee ee ee ee ee EE ee kk ee ee ee RE Ee ee ee ee ee 20 245 DIED 2 Scan High Re es ee RE ee ee ed ee DE 20 LAG Galilese Ee ee ae De emer ene ee SEERE ERE ee E
10. been scanned after scanning completion v 9 NVN i dyrs hiv N y LY e oes s fm o Edom c c oe oar DOLLA je RR ARK Figure 6 4 Image Dentition 6 2 3 Image Chart When you click the Image Chart button in the tool box it displays an image on the top and the chart on the bottom The chart provides the international standard teeth number in the center You can drag an image from the image window or task bar and align them on the chart G 110 109 108 107 106 105 104 103 102 101 201 202 203 204 205 206 207 208 209 210 G 411 410 409 408 407 406 405 404 403 402 401 301 302 303 304 305 306 307 308 309 310 3 Figure 6 5 Image Chart User Manual OuantorDentVet TM 806 EN 6 2 4 Chart When you click the Chart button in the tool box the chart is provided in full screen Figure 6 6 Chart 6 2 5 Template When you click the Template button in the tool box templates are provided that can scan the Full Mouth Series Drag images from the image field or task bar and align them on the template Figure 6 7 Template 6 3 Image Scan 6 3 1 For Standalone version 1 Enter study information in the New Study screen and click Next Or select a study in User Manual OuantorDentVet TM 806 EN the Study List screen and click Scan 2 Place an IP on the scanner tray and push it into the scanner 3 The screen displays the scanning progression 000003 2014 01 16 0 M
11. the image workstation The system has following components FireCR Dental e Fire ID OuantorDentVet Safety Instruction To ensure the safety of patients staff and other people any changes to software and hardware delivered by 3D Imaging amp Simulations Corp may only be made with prior written permission from 3D Imaging amp Simulations Corp Responsibilities If unauthorized changes have been made to software and hardware components delivered by 3D Imaging amp Simulations Corp the warranty by 3D Imaging amp Simulations Corp becomes void 3D Imaging amp Simulations Corp will not accept any responsibility or liability for the improper functioning of the product in such a case User Manual OuantorDentVet TM 806 EN 1 1 Major Features Image Acquisition and Management QuantorDent supports various image acquisition methods that meet the needs of dental hospital It can be used in a simple structure where one workstation is connected to a scanner for basic use as well as in a multi structure where multiple image workstations are connected to multiple scanners When multiple systems are used it supports Fire ID which enables automatic image classification to designated patient and test information regardless of the scanning location Image Processing To create an optimal image you can apply different functions including cropping enhancing edges and increasing contrast You can also add or delete images and modify t
12. upper left corner of the rectangle and then drag the mouse to the desired position of the lower right corner of the rectangle and release the mouse button Click on an area within the rectangle to move it Drag the control points to resize the rectangle 4 Ellipse Draws an ellipse Click the mouse at the desired position where the top and left most point of the ellipse would intersect drag the mouse toward the bottom right and release the mouse after reaching a desired size and shape Click on an area within the ellipse to move it Drag the control points to resize the ellipse Polygon Draws a polygon A control point is added every time you click the mouse Double click when you are done drawing the polygon Click on an area within the polygon to move it Drag the control points to change the corners of the polygon Free Draw Creates a free draw selection Click and drag the mouse to the desired shape Release the mouse when you are done drawing You can click inside the selection to move the free draw selection Pixel Value Measures pixel value Click and drag the mouse and the coordinates x y and pixel values p of the pixel at the cursor position will be displayed on the screen x 270 y 270 p 348 User Manual OuantorDentVet TM 806 EN Profile Draw a straight line in the same manner as measuring a distance and a profile dialog box will be displayed automatically Distance Start point
13. 0 V Canine 2014 02 07 15 29 30 TASK UST 2014 01 16 O N 403 303 Onn E O 206 207 208 209 E Le N aide 107 106 104 10mm 16 09 36 732 x 796 C 2048 W 4095 gea Figure 9 2 Review screen View caption bar The view caption bar Full screen Provides the review window in full screen View layout Adjusts the view layout Sooo Zoom Used to zoom in or out of the image Drag the image left right up or down using the mouse Pan Pans the image Drag the image left right up or down using the mouse Partial zoom in Zooms in a part of the image Image Opens image manipulation tools for rotating flipping and inverting images CO Measure Provides various measurement tools for measuring distance and angle Marking Provides marking tools File Displays DICOM file on the screen Tools Provides other tools O Apply Designates the range in which image adjustments apply User Manual OuantorDentVet TM 806 EN 9 2 View Caption Bar Figure 9 3 View Caption Bar Image layout Modifies the image layout When you click on the button a 3x3 grid appears on the screen as shown in Figure 9 4 Select your desired layout size You can select up to a 3x3 layout Figure 9 4 Image Layout Previous Page Next Page Close User Manual OuantorDentVet TM 806 EN 9 3 Full Screen This extends the review window to full screen as shown in
14. 014 02 07 16 45 00 127 0 0 1 Emergency Figure 11 1 Transport Information OW Today Searches studies from today only Study Searches studies with various conditions The same method as using the Study List is used 3 Delete Deletes the selected lines Previous Next Page Moves between pages User Manual OuantorDentVet TM 806 EN 11 2 List User Manual OuantorDentVet TM 806 EN 12 Settings 12 1 Screen Layout The Settings screen consists of a main category sub category and specific item Clicking on the main category item changes the sub category items Clicking on the sub category item changes the specific item in the selected sub category Setting values can be changed in the specific item Selected ROI Color User Information Apply Auto Window After Cropping Password For Processing Network Export Parameter Overlay Display Language System Figure 12 1 Settings OD Main category item list Sub category item list 3 Specific item list User Manual OuantorDentVet TM 806 EN 12 2 General 12 2 1 Options Selected ROI Color Select the ROI box color You can change the display Orange color by clicking the item Apply Auto Window Determines whether to apply Auto Window after Enabled After Cropping cropping the ROI box 12 2 2 User Information Institution name Designate the hospital name The entered values are included in the DICOM information Dept name The departmen
15. 10 Study list 10 1 Screen Layout In the study list you can manage scanned images Ge CO pp mo po G 6 R 2014 02 07 15 25 40 gase 2014 01 16 18 26 12 Emergency Canine LKE r me Figure 10 1 Study List Edit column It displays a diaglogue box that can edit the list column Today Searches studies from today only Search Searches studies with various conditions Filter Searches patients with the same ID Edit Edits the selected studies Delete Deletes the selected studies Add a study Adds a new study Scan Opens the selected study and goes to the Scan screen Review Opens the selected study and goes to the Review screen Transport Transports the selected studies Export Exports the selected studies to a CD DVD or a local drive Previous Next Page Moves between pages Preview Previews images in the selected studies User Manual OuantorDentVet TM 806 EN 10 2 List e Sorting When clicking the each column header the list is sorted by the selected column Each time the column header is clicked the sorting order changes Sort in ascending order Sort in descending order Multiple selections You can use the check boxes for multiple selections To select all lists use the check box located in the column header Move between pages The mouse wheel or page button can be used to move between pages Column width change To change the column width hold and move th
16. E ER ER ER ER Ee ER ee Ee RE ee EE enken ee ee ee eek eek ee ee 39 VD TRCN ON acer cess E sn ee oan gece eee eee 40 7 8 QA Image Adjustment see see ee ee ee ee ee ee ee 41 7 9 OA Image Processing ee e 42 7 10 Image Transport see eee eee eee 43 Z114 mage He RE EE N EO N Ee Rre 43 G Ed OE N Ee E dd 8 1 Screen LayYOU sees eek EER ER ee Ee ee EE ee ee EE ee ee ee ee ee ee ee ee ee 44 EN EER EE EE ee eee 45 User Manual QuantorDentVet TM 806 EN om eee eee eee 46 9 1 Screen LayYOU iss seek EER EE ER EE ek Ee ee Ee ee Ee ee ee ee Ee ee ee ee ee 46 9 VEE OON T EE ER OE OR GE Ge EE Oe 48 E SE Te EE 49 94 Image Processing sese eee eee 50 9 5 Measure 0s ccc eee ee eee 51 96 MEE see ER EE EE ne ee eee ee EE eee 54 2 FC again I ee ee Pe ee de ei 54 9 8 oie EE N N 54 92 92 ApPIY EE EE EE N ken ken ken ken rkrnnee 55 10 Study EE 56 10 1 Screen LayYOU sesse sesse ER EE EER EE EER ER ek Ee ee Ee ee Ee ee Ee ee ee nn ee 56 T 57 OES ot ele RE eT eT 58 te OE 59 EE 59 11 Confirm Transport Results ee ee Ee Ee Ee ee Ee ee Ee ee ee 61 Hi elc lt ee TAY OUT iese ee ee SENE Ee es De ie DER 61 sk NE EE OE EE A EE OE en 62 12 elle OE N N 63 EL ook ec WOU EE 63 IP ONC EE 64 ES oo ENE ER EE N N EE N 64 12 2 2 User AFMA OR asses see ee ee ok Ro ee Reid ke ee ee ee ee ge N ed n ed 64 12 2 3 Password for Processing Parameter sse eee sesse ee ee ee ee ee ee Re ee ede ee ee ee 64 12 2 4 eo IE ed
17. Figure 9 5 Emergency ID000001 2014 01 16 0 V Canine 2014 01 16 18 25 39 O N 10mm Onn E 1540 x 1368 C 2048 W 4095 2014 02 07 15 27 58 KR 10mm Figure 9 5 Full Screen User Manual OuantorDentVet TM 806 EN 9 4 Image Processing Rotate counter clockwise 90 degrees rr Rotate clockwise 90 degrees Bilateral right and left flip Up and down flip Reset the image to the initial status Negative image Fit to the screen size 100 size User Manual OuantorDentVet TM 806 EN 9 5 Measure BE e Rectangle Distance Measures distance Click the start and end point of the measurement A straight line is displayed between the two points and the measurement value is displayed at the end of the Straight line You can move the measuring line by dragging it You can move either one of the two control points by dragging them with your mouse You can also move the position of the measurement values by dragging them with your mouse Angle Measures an angle Click on the center point of the angle you wish to measure and then click on two control points You can move both lines at once by dragging You can also move either one of the two control points You can also move the position of the measurement values by dragging them with your mouse User Manual OuantorDentVet TM 806 EN Rectangle Draws a rectangle Click the mouse at the desired position of the
18. QuantorDent Vet User Manual Image Acquisition and Diagnosis Software Doc No TM 806 EN Rev 0 2 2 February 2014 Part No CR FPM 11 006 EN 3DISC FireCR Quantor and the 3D Cube are trademarks of 3D Imaging amp Simulations Corp South Korea and its affiliates All other trademarks are held by their respective owners and are used in an editorial fashion with no intention of infringement The data in this publication are for illustration purposes only and do not necessarily represent standards or specifications which must be met by 3D Imaging amp Simulations Corp All information contained herein is intended for guidance purposes only and characteristics of the products and services described in this publication can be changed at any time without notice Products and services may not be available in your local area Please contact your local sales representative for availability information 3D Imaging amp Simulations Corp strives to provide as accurate information as possible but shall not be responsible for any typographical error Copyright 2014 3D Imaging amp Simulations Corp all rights reserved printed and published 3DIS IMAGING in South Korea by 3D Imaging amp Simulations Corp User Manual OuantorDentVet TM 806 EN Contact IDIS IMAGING 815 Tamnip Dong Yuseong Gu Daejeon Korea Tel 82 42 931 2100 Fax 82 42 931 2299 Website www 3DISCimaging com E mail info 3DISCimaging com 3DISC Am
19. TASK LIST 2014 01 16 Figure 6 8 Scan in Standalone version 4 When the scan is completed the image is provided on the screen Note When you insert the tray into a scanner without opening the study the scanner conducts scanning but does not transport the image to QuantorDent User Manual OuantorDentVet TM 806 EN 6 3 2 For Client version 1 Enter study information in the New Study screen and click Next Or select a study in the Study List screen and click Scan 2 Tag an IP to get the image on the Fire ID Confirm that a task is added to the task bar GE Figure 6 9 Scan in Client version 3 Radiate the X ray on an IP 4 Place the IP on the scanner tray and push it into the scanner 5 The navigation bar displays the scanning progression KS 407 406 405 404 x PO z e x Figure 6 10 Indication of scanning progression 6 When the scan is completed the image is provided on the screen Note In the Client version you must open a study for tagging but you can use other studies during scanning User Manual OuantorDentVet TM 806 EN Image 7 1 Screen Layout When an IP scan is completed the Scan window displays the acquired image as shown in Figure 7 1 Emergency 1D000003 2014 01 16 V Canine D TASK LIST G 110 109 108 107 106 105 104 103 102 101 201 202 203 204 205 206 207 208 209 210 G 411 410 409 408 407 406 405 404 403 402 401 301 302 303 Ei O Figure 7 1 Image ou
20. anges and closes the dialog box O W E Cancels changes and closes the dialog box E Resets the program to default settings User Manual OuantorDentVet TM 806 EN 6 Scan In the Scan screen you can insert the IP into FireCR Dental and acquire the image 6 1 Screen Layout ID000004 2007 02 02 V Canine fi TASK UST G 110 109 108 107 106 105 104 103 102 101 201 202 203 204 205 206 207 208 209 210 G 411 410 409 408 407 406 405 404 403 402 401 301 302 303 304 305 306 307 308 309 310 311 Figure 6 1 Scan Screen Image window Displays an image selected in the Task List Support window Displays various information related to the teeth 3 Tool box You can change contents shown in the image view window and support window User Manual OuantorDentVet TM 806 EN 6 2 Tool Box Ad pp G 6 2 1 Figure 6 2 Tool Box Image window Displays images only Image window Dentition Displays images and dentition Image window chart Displays images and chart Chart Displays chart only Template Displays template instead of chart Image When you click the Image button in the tool box the image window only displays an image Figure 6 3 Image only User Manual OuantorDentVet TM 806 EN 6 2 2 Image Dentition When you click the Image Dentition button in the tool box it displays an image on the top and dentition on the bottom Using dentition you can record which teeth have
21. ct a destination folder to save images Format Select a format to save images Supported formats are as follows A DICOM B Bitmap Windows bit map file User Manual OuantorDentVet TM 806 EN OO S 6 amp OS C Raw Original file D Jpg Jpeg E Tiff Tiff Log message Displays the optical disk recording progression status Progression bar Indicates the image export process Study List Displays the list of selected studies Image List Displays the selected fields from the Study List If you click and deactivate an image the image will not be exported Select all Activates all images Deselect all Deactivates all images Anonymize It deletes patient name and ID when saving as DICOM images Close Closes the dialog box Abort Stops recording Burn Starts recording User Manual OuantorDentVet TM 806 EN 11 Confirm Transport Results In the Transport screen you can see the transport results of images sent to the image server 11 1 Screen Layout 2014 02 07 16 45 16 127 0 0 1 Emergency 2014 02 07 16 45 14 127 0 0 1 Emergency 2014 02 07 16 45 13 127 0 0 1 Emergency 2014 02 07 16 45 12 127 0 0 1 Emergency 2014 02 07 16 45 10 127 0 0 1 Emergency 2014 02 07 16 45 09 127 0 0 1 Emergency 2014 02 07 16 45 07 127 0 0 1 Emergency 2014 02 07 16 45 06 127 0 0 1 Emergency 2014 02 07 16 45 05 127 0 0 1 Emergency 2014 02 07 16 45 03 127 0 0 1 Emergency 2014 02 07 16 45 01 127 0 0 1 Emergency 2
22. e ee 20 AN ei EE EE OE RE OE EE KA 20 eee R e Ha lt lt 1 NE EO EE N OE EE E OE N N 20 3 Software Overview eee ee ee ER RR ER RR Ee ee ee ee EE ee Ee ee ee ee ee 21 3 1 Supported Resolutions e eee eee eee 21 3 FONO EE OE OE EE EE OO N EE N SET 21 3 3 Navigation Dar 22 34 Study let 22 3 5 Create New SUV sese ee 23 3230 Falen e e csr 166 ee EE EE EE ES EE EE EE Ee Ee 23 EN e EE EE EE EE N Ee N oe 24 3 8 Heview eee kk E DE 24 User Manual QuantorDentVet TM BOG EN d Home Screen eee 25 4 1 Screen LaYOU sesse EE Ek EE ER EE RR Ee eek Ee eek Ee eek Ee ee ee Ee ee ee Ee ee ee ee 25 42 System men 26 5 Create New Gud 27 5 1 Soreen LAV OU ae EE ER ee ee ee nens 27 5 2 Edit Column Dialog Box 29 OE oie EO EE OE anne EE OE E 30 6 1 Screen LayYOU esse EE EER EER ER EE ee Ee ee Ee ee Ee ee ee ee ee eek ee ee 30 6 2 Tool Dos 31 62l IMAGE RE OE EE N EO EO N EE OO N 31 622 Imaget DEntiON es ss Ee De is di Re RE BEE eee Oe Re me 32 623 oure e L EIE see EE ee ee ie EE ee EE ie eo EE GR ee 32 N ER RE EE N RR RE OE OR EE N 33 6 25 WOT AS eebe ee 33 e GOS e Te EE EE EE EE eee ee 34 6 3 1 For Standalone version 34 Goe eT 8 gt rA 157 SION BE 35 T R 10 OE EE EEE E A E 36 7 1 Screen LAY OE ass De ei ee ee ee 36 7 2 FOL EE Ee EET RNEEEER 37 E UR cre ee een ene me ne ee ee eee ee 38 lats POTON ID EE ee EE ER De 39 7 6 180 degree rotation sese 39 7 6 Auto Window eee E
23. e mouse from the edge of the column header Table 10 1 provides the column of study list Table 10 1 Study List Column erg Sex Patient sex Patentsex o oo Age Pastis ooo Patient breed W S Name Workstation name when run in Client mode User Manual OuantorDentVet 10 3 Edit Column Finish State Figure 10 2 Edit Column The columns to use in the Study List The columns not used in the Study List Moves the selected fields to the left or right The buttons are used to move between pages Moves the selected field upward or down to change the order Saves changes and closes the dialog box 90000000N Resets the program to default settings TM 806 EN User Manual OuantorDentVet TM 806 EN 10 4 Search Filter It selects the column where searching is applied When a filter has not been set and All is selected all columns are searched Keyword Enters keywords to search 3 Search Starts searching 10 5 Export 2014 01 16 18 25 30 Device r r 1 oca ge H 35 1 0 0MB 0 00 Figure 10 3 Export Device Selects a storage device to export the images to Optical disk attached to the PC are listed When selecting Local you can use other storage devices attached to the PC Label The label is recorded on the disk Media Type Displays the type of media inserted in the drive Local Folder This is activated when you select Local in the Device Sele
24. ericas 22560 Glenn Dr Suite 116 Sterling VA 20164 USA Tel 1 703 430 6080 E mail info 3DISCimaging com 3DISC Europe Gydevang 39 41 3450 Alleroed Denmark Tel 45 88 276 650 E mail info 3DISCimaging com User Manual OuantorDentVet TM 806 EN Warnings and Symbols used To ensure the safety of patients staff and other persons any changes to software and hardware delivered by 3D Imaging amp Simulations Corp may only be made with prior written permission from 3D Imaging amp Simulations Corp Please read the respective manuals of the connected devices such as of the X ray generator sensor or reader before starting to use the QuantorDentVetsoftware Following symbols will be used throughout this manual DANGER The functionality of the software can be destroyed in the case of incorrect use lf unauthorized changes have been made to delivered software and hardware components the warranty by 3D Imaging amp Simulations Corp becomes void 3D Imaging amp Simulations Corp will not accept any responsibility or liability for the proper functioning oh the product in such a case CAUTION The functionality of the software can be limited in the case of incorrect use Hints that require special attention NOTE Notes represent information that is important to Know but which do not affect the functionality of the software User Manual OuantorDentVet TM 806 EN Medical Device Security Users must take steps
25. gion Select all Selects all tasks Delete Deletes the selected tasks OON Transport Transports the selected studies The transport destination is added in Settings Print Prints the image using the Window Printer O Previous Next page Moves the page User Manual OuantorDentVet TM 806 EN 8 2 Print You can print out images with the Window Printer by selecting images in the task bar and clicking the Print button The printed page can be previewed on the left part of the screen 2014 02 07 18 58 57 Print Setting Figure 8 2 Print Layout Selects the layout of the image to be printed on film or paper EE i e Print Starts printing Setting Displays the Print Setting screen Close Closes the dialog box User Manual OuantorDentVet TM 806 EN 9 Review 9 1 Screen Layout This supports various image comparisons processing and measurement tools necessary for diagnosis The image view screen is composed with multiple views and each view consists of multiple images You can customize the view layout and image layout according to your needs Figure 9 1 View Image layout To display an image on the view you can simply drag an image from the task list When an image is dragged from the task list the view displays the selected image only Dragging a study displays all images of the study on the view User Manual OuantorDentVet TM 806 EN Emergency ID000001 2014 01 16
26. he image sequence at your discretion Built in Viewer QuantorDentVet not just simple image acquisition software but can also be used as a diagnostic viewer Like other viewers it can manage patient and test information and contains all basic viewer functions User Manual OuantorDentVet TM 806 EN 2 Installation 2 1 Installation Environment 2 1 1 Recommended Computer Environment Operating system Microsoft Window XP 7 and 8 CPU Intel CORE i5 Memory 4G or higher 2 1 2 Minimum Computer Requirements Operating system Microsoft Window XP CPU Intel Processor Memory 2GB User Manual OuantorDentVet TM 806 EN 2 2 Installation 2 2 1 Select components and click Next Software Installation Log on to a PC with an administrator account Connect the USB dongle to a USB port Insert the installation CD The installation program runs automatically If it does not automatically run manually find a file named QuantorDentVet 2 x x Setup exe in the CD and run the file Click the Next button as shown in CG GuantorDentVet 2 0 143 Setup the Figure Welcome to the QuantorDentVet 3DISC 2 0 143 Setup Wizard QuUANTOrDENT ge wizard wil guide you through the instalation of Vet QuantorDentVet 2 0 143 It is recommended that you dose all other applications before starting Setup This will make it possible to update relevant system files without having to reboot your computer Clic
27. ilters screen 7 9 QA Image Processing This is used to adjust image processing filters Adjusting the image requires expert knowledge about images Adjusting the image without proper knowledge may result in lower image quality Figure 7 5 Image processing filter User Manual OuantorDentVet TM 806 EN Contrast Increases the image contrast The level can be adjusted from 0 to 10 Higher levels increase the intensity Filter is not applied when 0 is selected Detail contrast Enhances contrast of regions with a slight change in brightness The level can be adjusted from 0 to 10 Higher levels increase the intensity Filter is not applied when 0 is selected 3 Edge Enhancement Emphasizes the border lines It is used to increase visibility of blood vessels or small calcifications The level can be adjusted from 0 to 5 Higher levels increase the intensity Filter is not applied when 0 is selected 4 Edge Frequency Designates the range of the edges to emphasize The level can be adjusted from 0 to 5 Lower level emphasizes the smaller edges Higher levels emphasize the bigger edges Latitude Reduction Compresses the low frequency regions to improve the overall visibility of the image The level can be adjusted from 0 to 10 Higher levels increase the intensity Filter is not applied when 0 is selected Noise Reduction Reduces the image noise The level can be adjusted from 0 to 10 Higher levels increase the intensit
28. k Next to continue Figure 2 1 Welcome Dialog Box Co QuantorDentVet 2 0 143 Setup Choose which features of QuantorDentVet 2 0 143 you want to 3DISC Ee PIs Choos Check the components you want to install and uncheck the components you don t want to install Click Next to continue Select the type ofinstal QuantaDentiet gt Or select the optional QuantorDentVet Files Re oe C HASP HL Driver install Space required 79 5MB Figure 2 2 Components Dialog Box User Manual OuantorDentVet As shown in the Figure select language and click the Next button As shown in the Figure select the application type If you do not have QuantorDentVet Server select Standard Otherwise select Client of QuantorDentVet Server TM 806 EN Fy Select a language to Use Choose which features of QuantorDentVet 2 0 143 you want to install What lanquage do you want to use Selecta language for the Quant Figure 2 3 Select Language Dialog Box Co QuantorDentVet 2 0 143 Setup Client of QuantorDent Server Figure 2 4 Select Application Dialog Box User Manual OuantorDentVet TM 806 EN Co QuantorDentVet 2 0 143 Setup As shown in the Figure Choose Install Location 3DISC Choose the folder in which to install QuantorDentVet 2 0 143 select the installation path and Oeil click the Next button Setup will install QuantorDentVet 2 0 143 in the fo
29. ledge may result in lower image quality Processing Figure 7 4 LUT Curve LUT curve The LUT curve is applied to the image A default curve for each region is provided The user can adjust the curve to their preference To adjust the curve locate a point with the mouse and move it Clicking a point on the line adds a new point When the a point is dragged out of the box it is removed Histogram Shows the image histogram The bright region at the center is the region currently displayed on the screen The left part of the histogram indicates the frequency where the X ray penetration level is low and image is bright The right part of the histogram indicates the frequency where X ray penetration level is high and the image is dark Images have low pixel values in bright regions and high pixel values in dark regions Window Center Width Adjusts the window center and width of the image The window center is adjusted when you drag the image up or down and window width is adjusted when you drag the image left or right Dragging the sliders has the same effect as dragging the image User Manual OuantorDentVet TM 806 EN k gt Window Center Set Sets the curve and window value adjusted by the user as the default value for images of the current region 5 Load Calls and applies default curve and window values of the current region Reset Resets the curve D Processing Displays the Image Processing F
30. llowing folder To install in a different folder click Browse and select another folder Click Install to start the installation Destination Folder C WQuantorDentvet t Space required 79 5MB Space available 18 7GB Nullsoft Install System v2 46 Figure 2 5 Select Installation Path The installation status is SHOWN GuantorDentVet 20143 Setup like the Figure 3DISC Installing Please wait while QuantorDentVet 2 0 143 is being installed IMAGING Extract hasp windows dl ed Show details Nullsoft Install System v2 46 Figure 2 6 Display Installation Status The dongle driver installation status is shown like the Figure Sentinel Run time Environment Please wait Figure 2 7 Installation of dongle Driver User Manual OuantorDentVet TM 806 EN Ca FireCRDriver 1 2 Setup Completed The FireCR USB driver The installation status is shown like the Figure like the Figure 6 When the installation is Quanto one AN successfully completed 3DISC Completing the QuantorDentVet shown like the Figure EE Aa ap ad LEER QuantorDeNt _quantorDentvet 2 0 143 has been installed on your Click Finish to finish the Vet ee installation Cikk Finish to dose this wizard Figure 2 9 Finish Installation User Manual OuantorDentVet TM 806 EN 2 3 Start and Exit 2 3 1 Start system 1 Turn on the Fire CR device 2 Turn onthe PC and monitor CAUTION Do not r
31. mAs SID 260 mm SID 260 mm SID 280 mm SID 260 mm Figure 2 14 Calibration CAUTION SIZE 4C IP must be used for calibration User Manual OuantorDentVet TM 806 EN 2 4 1 Step 1 Erase At first you can see the Erase button flickering Place the IP on the tray and insert it When the erase is completed the Scan Blank part starts flickering 2 4 2 Step 2 Scan Blank Place an IP that has not been radiated with X Rays on the tray and insert it At the scan completion the Scan Low Dose part starts flickering 2 4 3 Step 3 Scan Low Dose Adjust the X Ray imaging settings to 70kVp 0 49mAs and scan the IP from the recommended X Ray imaging distance Place the IP on the tray and insert it Once the scan is completed the measurement is displayed below the button It should be between 1500 and 5000 If so click Accept to process the next step If not click Reject to repeat Step 3 2 4 4 Step 4 Scan Mid Dose Adjust the X Ray imaging settings to 70kVp 1 4mAs and scan the IP from the recommended X Ray imaging distance Place the IP on the tray and insert it Once the scan is completed the measurement is displayed below the button It should be between 8000 and 16000 If so click Accept to process the next step If not click Reject to repeat Step 3 2 4 5 Step 2 Scan High Dose Adjust the X Ray imaging settings to 70kVp 3 5mAs and scan the IP from the recommended X Ray imaging distance Place the IP on the tray and insert i
32. studies This displays the same screen as adding an image server 3 Delete Deletes the selected servers 4 Network test Checks the connection by sending DICOM Echo to the selected server Move up Moves the selected server up User Manual OuantorDentVet TM 806 EN Move down Moves the selected server down Timeout The connection is dropped if a response is not received within the set amount of time Once a server is added the check boxes for each item are automatically activated Quantor sends images to all checked image servers in the list order 12 4 2 Options Automatic Study images are transferred automatically Disabled transfer of studies after completion of the study Series Encoding Set DICOM Encoding method A series has one image Aseries has one image Aseries has multiple images 12 5 Overlay 12 5 1 Marking Here you can edit predefined markings that appear when adding marking on the image in the Scan screen After entering text in the input field you can perform the following actions Add Add a new marking Modify Modify the selected marking Delete Deletes the selected marking Move up Moves the selected marking to one line up Move down Moves the selected marking to one line down 12 5 2 Auto Marking Margin This sets the margins when markings are automatically added to an image Each setting value shows margins by compared to the width and height of the image
33. t Once the scan is completed the measurement is displayed below the button It should be between 30000 and 45000 If so click Accept to process the next step If not click Reject to repeat Step 3 2 4 6 Calibration This creates a Calibration data file 2 4 Upload If you click the Upload button the calibration data is transferred to the scanner for storage 2 4 8 Download If you click the Download button stored calibration data in the scanner is downloaded to the PC User Manual OuantorDentVet TM 806 EN 3 Software Overview 3 1 Supported Resolutions Landscape resolutions with 16 9 4 3 and 5 4 ratios are supported Portrait ratios are not supported The horizontal resolution of the monitor must be at least 1280 pixels and the vertical resolution of the monitor must be at least 768 pixels Table 3 1 provides the recommended resolution Table 3 1 Supported Resolutions Screen ratio Screen resolution 1366 x 768 1280 x 800 1400 x 900 1600 x 900 1920 x 1080 4 3 5 4 1280 x 1024 3 2 Home The Home screen is the first screen that appears when the program is run From the Home screen you can create a new study or view existing Studies Figure 3 1 Home Screen User Manual OuantorDentVet TM 806 EN 3 3 Navigation Bar You can see the Navigation Bar in the bottom of screen The Navigation Bar is always displayed while the program is running allowing the user to easily switch screens during a
34. t name where the system is installed The entered values are included in the DICOM information 12 2 3 Password for Processing Parameter Confirm password Enter the password again N Require Password for Set the system to request a password when Enabled Modifying Image attempting to modify LUT and processing Processing parameter Require Password for It activates password screen when saving default Enabled Saving Image Process values in the LUT and processing windows Values 12 2 4 Display Language Language Select language Language selected upon product installation User Manual OuantorDentVet TM 806 EN 12 3 Fonts 12 3 1 General Name of font used on the screen Malgun Gothic Font size Size of screen font 10 Adjustable from 8 to 12 points 12 3 2 Marking Font name Name font used for marking ARIAL Font size Size of marking font 22 Adjustable from 16 to 30 points 12 3 3 DICOM Printer Font name Name of font to use for printing ARIAL Font size Size of printing font Adjustable from 8 to 12 10 points User Manual OuantorDentVet TM 806 EN 12 4 Network Export 12 4 1 Image Server This manages lists of DICOM servers to transport images General Image Server DICOM AE 100 100 100 100 1000 Fonts Options i image Overlay System Network Test Move Down Figure 12 2 Network Export CO Add Adds an image server Edit Edits the selected
35. task J Figure 3 2 Navigation Bar Home Studies scan Review BH OBP 3 4 Study list This displays a collection of windows that are related to the study You can go to this screen by clicking on the Study button in the Navigation Bar On the left side the study tool bar is located In the study tool bar you can select study related windows for the study list work list and transport Figure 3 3 Studies Screen You can perform various tasks by searching existing studies and selecting a study You can confirm the transmission results of the acquired images User Manual OuantorDentVet TM 806 EN 3 5 Create New Study The New Study screen is the first page to start a scan After entering the necessary patient information and study information and adding a new study you can begin a scan Figure 3 4 Create New Study 3 6 Patient Information On the top of all screens except the Home and New Study screens there is a patient Information Bar The Patient Information Bar displays patient information and other related information Figure 3 5 Patient Information Patient Name Patient ID Patient s Date of Birth Patient s Age Patient Sex M Male F Female O Other SM Sterile Male SF Sterile Female S Sterile Ad app Current Time Model Name System Q User Manual OuantorDentVet TM 806 EN 3 7 Scan In the Scan screen you can insert an IP into the FireCR
36. to secure their networks and protect their Medical Information Systems which includes a risk assessment strategy network defense in depth strategy business continuity planning etc v User Authentication Only authorized users should log on to computers on which medical information systems are installed Password Security In today s world passwords can be compromised in literally seconds by using a wide variety of tools and techniques To lower the possibility of a compromised password it is vital to adhere to a set of protocols Choose a password between 7 10 characters using both alpha and numeric characters e Do not share the password Do not base the password on a pet s name a relative s name or any dictionary word e Do not write down the password e Do not leave the account logged on User Access Control Configure the workstation to prompt for logon after coming out of stand by mode Internet Usage Accessing to the Internet exposes the computer to a plethora of vulnerabilities such as Viruses e Spyware Trojans Hostile Codes It is not recommended to install any unauthorized software on the computer Peer to peer software can expose your entire hard drive to any individual running the same type of software Antivirus Products Use of antivirus software can increase CPU and memory usage which can cause a slight degradation in the performance of the system However functionality should not
37. tput ROI box A tool for cropping the valid region of the scanned image ROI Displays or hides the ROI box Marking Adds marking on the image Rotation flip It rotates the image or flips it 180 degree rotation Rotates the image 180 degrees Auto window Automatically adjusts the image brightness and contrast Reject It adds Rejects marking the image Cp po OG ma PP OA Calls tools for adjusting image details Transport Transports the image Memo Used to enter image related contents User Manual OuantorDentVet TM 806 EN 7 2 ROI After completion of scanning the ROI box is automatically provided as shown in Figure 7 1 along with the image When you click and drag the ROI Box to the desired location and then double click the ROI Box or click on the ROI button the ROI is cropped and fitted to the screen as shown in Figure 7 2 To adjust the size of the ROI Box drag the small rectangles at each corner of the ROI When transmitting or printing the image only the ROI are used To bring up the ROI Box again double click on the image or click on the ROI button Emergency 03 2014 01 16 0 d Canine TT Review Figure 7 2 Image with cropped ROI region User Manual OuantorDentVet TM 806 EN 7 3 Marking This adds markings on the image You can add markings to the image by selecting a predefined marking or manually typing text Add predefined marking Click on the Marking button Select
38. un any application software other than QuantorDentVet during operation of the scanner This may slow the scanner response 2 3 2 Start program After successfully booting Windows double click the QuantorDent icon on the desktop screen as shown in Figure 2 10 to start the QuantorDent program O p Scan Review Studies Figure 2 10 Home Screen User Manual OuantorDentVet TM 806 EN QuantorDentVet Figure 2 11 Desktop Icon 2 3 3 Exit program Select the system button that looks like Figure 2 12 on the Home screen Figure 2 12 System button You can select Exit in the system menu to close the program Figure 2 13 System menu User Manual OuantorDentVet TM 806 EN 2 4 FireCR Dental Calibration In the system menu select IP Calibration to open a window as shown in Figure 2 14 Process calibration as instructed in the window CAUTION Calibrate the scanner before use The Please calibrate system message pops up if the scanner is not calibrated or calibration data does not exist It is recommended to calibrate the reader after moving it and as a part of regular maintenance Device Calibration The X ray beam should cover the entire IP area needs SIZE4C IP UI Erase Calibration Ed ScanBlank ScanLowDose ScanMidDose ScanHighDose ESS sss sss EL 224 3929 9055 34136 50 500 1500 5000 8000 16000 30000 45000 0 00kVp 70 00kVp 70 00kVp 70 00kVp 0 00mAs 0 49mAs 1 40mAs 3 50
39. y Filter is not applied when 0 is selected D Set Sets the filter values adjusted by the user as the default value for images of the current region Load Loads and applies filter values of the current region Reset Resets the filter LUT Displays the LUT Curve adjustment screen 7 10 Image Transport Immediately transmits the current image to the image server designated in Settings 7 11 Image Comment You can add a memo about image related findings and extra information User Manual OuantorDentVet TM 806 EN 8 Task List 8 1 Screen Layout This is a list of to be scanned tasks Tasks are group by unit of study and arranged in chronological order The user can select the desired region and perform a scan The task list consists of lists of studies and each study is made up of lists of tasks The check boxes located to the right of the task list are used to select tasks Emergency ID000001 2014 01 16 M Canine E G E O 206 207 208 209 15 28 07 107 106 104 G 110 109 108 107 106 105 104 103 102 101 201 202 203 204 205 206 207 208 209 210 G MURE bs 411 410 409 408 407 406 405 404 403 402 401 301 302 303 304 305 306 307 308 309 310 311 Figure 8 1 Task List Study bar Displays date time and description of the study Studies on the day of scanning display time only while studies before the scanning day display date only Task bar Displays image preview and scanning re