1. Con necting Machines IDT1 1420G GP Quick Installation Guide First Edition May 2013 1 Overview Welcome to NXN s iDT1 1420G 1420GP industrial cellular modem series With 1 Port serial RS 232 422 485 4 Digital Input 2 Relay Out the cellular modems that allow you to connect serial devices to the GSM GPRS network Besides iDT1 1420GP is embedded with GPS module which is suitable for real time GPS tracking applications 2 Package Checklist Before installing iDT1 1420G GP verify that the package contains the following items IDT1 1420G IDT1 1420GP e1420G Device e1420GP Device eDIN Rail Clip eSIM Cover eGSM Antenna eGSM Antenna eTerminal block x 2 eGPS Antenna eFemale RS 232 cable x 1 eTerminal block x 2 eiDT Document amp Software CD eFemale RS 232 cable x 1 eiDT Document amp Software CD 3 Hardware Introduction As shown in the following figures iDT1 1420G GP the front has GSM antenna connector six LED indicators and two terminal blocks one of terminal block for the RS 232 422 485 interface another one for digital input relay out and power The rear has terminal resistor switch SIM slot and reset console button for the RS 422 485 interface the terminal resistor switch for mount or Unmounts internal terminal resistors on the wire and iDT1 1420G only different with iDT1 1420GP is the iDT 1420GP has a GPS antenna connector for GPS receiver IDT1 1420G 65M Antenna GSM Signal Strength Status Digital Input
2. 7 Hardware Specifications IDT1 1420G Cellular Interface Radio Frequency Standard Band Frequency Multi slot Class Capable Mobile Station Class Coding Schemes Transmission Rate Transmission Power SIM Card Type E Serial Interface Number of Ports Serial Connector Serial Signal Types Terminal Resistor Data Bits Stop Bits Parity Flow Control Baud rate ESD Protection E I O Interface Digital Output Digital Input mE Power Requirements Power Input Input Voltage Power Consumption m Physical Characteristics Housing Weight GSM GPRS Quad band 850 900 1800 1900 MHz Software Selectable Class 10 Class B CS1 CS2 CS3 CS4 Up to 85 6K bps Transfer Mode class 10 8Rx 2Tx 1 4 Watts GSM 850 EGSM 900 Transfer Mode class 10 8Rx 2Tx 1 Watt DCS 1800 PCS 1900 1 8V 3V Terminal block RS 232 422 485 Software Selectable None 120Q Hardware Selectable 5 6 7 8 1 1 5 2 None Even Odd Mark RTS CTS XON XOFF for RS232 XON XOFF for 422 and 485 100 bps to 230 4 Kbps 15 KV 2 relay outputs with current carrying capacity of DC 1A 24 VDC AC 0 5A 125VAC 4 dry contact inputs open on grounded off Terminal block 9 to 35 VDC 170 mA idle 650 mA peak 12VDC Aluminum 300 5g Dimensions L x W x H E Environmental Limits Operating Temperature Storage Temperature Ambient Relative Humidity IDT1 1420GP E Cellular Interface Radio Frequency Standard Band Freque
3. amp Relay out Cy ty eet Serial Port RS232 RS422 RS485 IDT1 1420GP Reset Console Buttom SIM Cover Screw Holes RESET CONSOLE C SIM Card Slot GPS Antenna RS427 RS485 Terminal Resistors Switch SIM Card Slot DIN Rail Screw Holes Reset Console Buttom RESET CONSOLE GSM Antenna Digital Input amp Relay out Serial Port R5232 R5422 RS485 Status GSM Signal Strenght R422 R5485 Terminal Resistors Switch Reset Console Button IDT1 1420G GP has one push button on the rear The button function shown as following figures 1 Click the Reset button to restart iDT1 1420G GP 2 Press the Console button continuously for 3 seconds to entering console mode to configure iDT1 1420G GP RESET CONSOLE Reset Console Button LED Indicators IDT1 1420G GP that contains six LED indicators as described in the following table Console Mode LED Name LED ICON LED Function Continuously dark 1s then bright 1s Continuously dark 1s then bright 1s Continuously dark 1s then bright 1s GSM Signal Always dark Connection Mode LED Name LED ICON LED Function Continuously dark 1s then bright 1s Normal running Fast blinking Hardware abnormal Dark Not obtain an IP address Bright Already obtain an IP address Dark No network connection establish Bright Least one connection has established 4 Hardware Installation Procedure STEP 1 After removin
4. T1 1420G STEP 8 Append SIM cover or DIN Rail clip to iDT 1420G GP iDT1 1420GP RESE GUM ULE IDI 1 1420G Wall or Cabinet Mounting The IDT1 1420GP contains two L plates for attaching the device to a wall or the inside of a cabinet Use two screws per bracket to attach the IDT1 1420GP to a wall or cabinet The heads of the screws Should be less than 6 0 mm in diameter and the shafts should be less than 3 5mm in diameter as shown by following figure l n C4 ar ae i 3 E Tik el l 2 3 an 5 3 DIN Rail Mounting The iDT1 1420G contains DIN Rail attachments When snapping the attachments to the DIN rail make sure the stiff metal springs are at the top Please refer to following figure by step to correct mounting j 4 5 Terminal Resistors for the RS 422 RS 485 DIP switches on the bottom of IDT1 1420G GP are used to set the internal 1202 resistor wiring to each Serial port Terminal Resistors DIP Switch RESET CONSOLE 6 Pin Assignments Pin assignments for iDT1 1420GP 7 2 s s 7 s ul a Pos ore ou oro no oom no wo com no ono wn Tar ers ars ose eno ore mo xo pen eno eno eno a S l t2 e s s 7 w n a Dna ox tx wa eno na mx rae na eno eno eno Coo O O R5422 R5485 pam fo e e oe oe Pin assignments for iDT1 1420G EEL m ml ss DIO Tal _ Digital Input ps oa cats
5. g iDT1 1420G GP from the box you should connect RS232 cable to the terminal block and connect the cable to laptop or PC STEP 2 Connect GSM antenna to iDT1 1420G GP for provide better signal environment to easy access GSM GPRS network r i IDT1 1420GP iDT1 1420G STEP 3 Connect GPS antenna to iDT1 1420GP for receive signal of satellites x TA ka i died ft fel T n E i Pepe i N Ho H gt fa i S3 He l gp p a 5 STEP 4 Wiring power cable to iDT1 1420G GP 9 39 VDC STEP 5 Press Console button continuously for 3 seconds to entering console mode to configure iDT1 1420G GP Note Please refer to LED indicators section to make sure iDT1420G GP already entered to console mode RESET CONSOLE Reset Console Button STEP 6 Software Installation Information and configure iDT1 1420G GP To install iDT Administration Utility EZAdm insert the iDT Document amp Software CD into your laptop s computer s CD ROM drive Once the IDT Installation CD window opens click on the Installation icon and follow the instructions on the screen You can click on the Documents icon for more information about iDT Administration Utility EZAdm click on the Documents icon and then select iDT1 Series User s Manual configured iDT1 1420G GP to open the user s guide for STEP 7 Insert SIM card to iDT1 1420G GP ID1T1 1420GP RESET CONSOLE iID
6. ncy Multi slot Class Capable Mobile Station Class Coding Schemes Transmission Rate Transmission Power SIM Card Type E Serial Interface Number of Ports Serial Connector Serial Signal Types Terminal Resistor Data Bits Stop Bits Parity Flow Control Baud rate ESD Protection E 1 O Interface Digital Output Digital Input mE Power Requirements Power Input Input Voltage Power Consumption m Physical Characteristics Housing Weight Dimensions L x W x H E Environmental Limits Operating Temperature Storage Temperature Ambient Relative Humidity E GPS Interface Chipset Frequency Protocol Chip set TTFF Accuracy 92 x 86 x 40 mm 3 62 x 3 38 x 1 57 in Standard Models 40 to 85 C 40 to 185 F 40 to 85 C 40 to 185 F 5 to 95 RH GSM GPRS Quad band 850 900 1800 1900 MHz Software Selectable Class 10 Class B CS1 CS2 CS3 CS4 Up to 85 6K bps Transfer Mode class 10 8Rx 2Tx 1 4 Watts GSM 850 EGSM 900 Transfer Mode class 10 8Rx 2Tx 1 Watt DCS 1800 PCS 1900 1 8V 3V Terminal block RS 232 422 485 Software Selectable None 120Q Hardware Selectable 5 6 7 8 1 1 5 2 None Even Odd Mark RTS CTS XON XOFF for RS232 XON XOFF for 422 and 485 100 bps to 230 4 Kbps 15 KV 2 relay outputs with current carrying capacity of DC 1A 24 VDC AC 0 5A 125VAC 4 dry contact inputs open on grounded off Terminal block 9 to 35 VDC 180 mA idle 680 mA
7. peak 12VDC Aluminum 315 5g 92 x 86 x 40 mm 3 62 x 3 38 x 1 57 in Standard Models 40 to 85 C 40 to 185 F 40 to 85 C 40 to 185 F 5 to 95 RH SIRF Star VI L1 1575 42MHz NMEA 0183 ver 3 0 GGA GSA GSV RMC Reacquisition less than 1s Hot start less than 1s open sky Warm start less than 35s open sky Cold start less than 35s open sky Position within 10m for 90 Velocity 0 1m s TEL 886 2 86671865 Ext 111 Website www nxn com tw Email support nxn com tw 2013 NXN Technology Co Ltd All rights reserved