Home
635060U Prisma User
Contents
1. 20 CONCEPT 4000 Revision 2 0 May 2012 Home Auxiliary Control Individual Terminals may be programmed to allow Users to control specified Home Auxiliaries without needing to Log on to the Terminal Home Auxiliaries can be turned On turned Off or turned On for a timed period in minutes or seconds Typical applications for Home Auxiliaries include lighting heating pool pumps speaker switching irrigation etc NOTE Access to some Home Auxiliaries may be limited to particular User Types These Home Auxiliaries can only be controlled by Users with access to the Home Auxiliaries Control Menu lt MENU gt lt 9 gt 1 After logging on and selecting the Menu option control operations will be the same as described below Selecting a Home Auxiliary to View or Control If this option is enabled press the lt Menu gt FUNCTION key highlight the Control icon using the SCROLL WHEEL then press lt OK gt Conirol OR simply press the lt RIGHT gt arrow key The display shows the current status of up to five Home Auxiliaries in alphabetical order Home Aux Control Garden Lights Pond Fountain Exit OK Toggle Timed On Use the SCROLL WHEEL or lt UP gt and DOWN Arrow keys to select a Home Auxiliary to view or control CONCEPT 4000 Home Aux Control Garden Lights Enter On period for Pond Fountain O0 Hr 00 min 00 sec Cancel OK Accept Can t control this Aux Prisma Co
2. The Installer s Telephone number Welcome to your company name gt Concept Security by Inner Range Menu Temp 25 3 C Log On The Indicator Lamps Eight multi purpose lamps are provided for quick indication of Area and Alarm Status and or other conditions The settings can only be programmed by the Installer who can also advise on the appropriate options When programmed for Area Array the lamps will indicate the status of up to 8 sequential Areas in the following manner Off Area Off Disarmed On Area On Armed Flashing Alarm in this Area Lamp No 1 2 3 4 o 6 7 8 a OF inner range Lamps 5 to 8 may have been programmed to indicate other conditions please record their purpose here 8 CONCEPT 4000 Revision 2 0 May 2012 USER OPERATIONS User operations are the basic day to day operations performed on the system These include Turning Areas ON and OFF Arming and Disarming Acknowledging Alarm messages Accessing Doors and or Lifts Viewing Alarm Review information and Area Status Controlling Outputs Turning Home Auxiliaries ON and OFF The system has been designed for simple operation providing straightforward procedures and display prompts in plain English text However if a User is unsure of what to do next a simple press of the HELP key provides additional assistance Most User operations begin with the same simple procedure The User must LOGON to the Terminal by entering t
3. CONCEPT 4000 Prisma Colour Graphic Terminal User Manual CONCEPT 4000 Prisma Colour Graphic Terminal User Manual Rev 2 0 e OF inner range CONCEPT 4000 Installed by ABC Security NOTE This User Manual is intended to be read in conjunction with the Concept 4000 User Manual which describes many additional User operations i 2 CONCEPT 4000 Revision 2 0 May 2012 CONTENTS TMS IG DOW H 3 Der lt LED Display FH 6 Indiedtor Lampe sores n dae uceebwceass oasis anadeaneanduauneeaaeeaenesuat 1 V If Used USER ALARM SYSTEM OPERATIONS eee eee eee een n noooue 8 El Ru o t EA AT A A 8 LI COC O we 9 Torne Ateas OFE sxcessrcsotaacscncadenenstnnctacssanccetansnetinasnebeivendineneeteesinecsinn 10 C De o Pomme 12 L DU PN u8 DERE 13 Act vyatng IP nsi TUM 15 Activating a Duress Alarm sedere onerosa i Y ERR ni dan Prid es a usa max cEDu GU UdUE 15 ME o 09 10 E UDIUIRINCOETONUTSSETTTTETIS 16 USER ACCESS CONTROL OPERATIONS e eee eee eee eonun 17 USER SYSTEM STATUS amp CONTROL OPERATIONS 18 View Alarm Review information eee eene 18 View Systemi Information siroja Mei p UNA oii oben dina doo nE Oda adu ood tei inn 19 L HomeAnuxilary Control oessnedatetu id ei Eet EIU hen Kass IbbRESUPi eeu e ee miauE 20 MENU OPTIONS naranvasdiercteivekeb ide vvEEERERTEEEH HEUTE S EEUPV EAE ERHEE PEE trevor 22 NS tr Me Meni em 22 Keyp
4. Group Options C ancel Holdup in the Concept 4000 User Manual Prisma Colour Graphic Terminal User Manual 9 CONCEPT 4000 LOGON Logging on is the first step performed in MOST operations 22 2 User code entry Enter your PIN ck e AG XR Cancel OK Accept Delete Good Morning Polly Nomial Area Control t Admin amp Sales Counter t Warehouse amp Board Room amp Training Room Menu Press On Area Lists END Enter your secret PIN Code using the digit keys then press the lt OK gt key Each digit pressed will be displayed as an asterix character If you make an error while entering your PIN code press lt Delete gt to delete the last character entered or the lt END gt key to start again If there are no messages to be acknowledged the Display may first greet and identify you Note Greeting can be disabled in V3 or later If there is a message to be acknowledged refer to Acknowledge an Alarm The Area Control screen is now displayed with the first Area or Area List that you are allowed to control highlighted and a text prompt for the relevant action on that Area shown at the bottom of the screen i e Press On or Press Off When your operations are complete you must Logoff the Terminal by pressing the END key 10 CONCEPT 4000 Revision 2 0 May 2012 Turning Area s OFF Once you have Logged on to a Terminal and can view the Area status you may per
5. Note the alarm details then press Heat Rise Detector The lt Accept gt FUNCTION key to acknowledge in Kitchen the message or The lt Later gt FUNCTION key to postpone acknowledgement of the alarm If there are other Areas that have had an alarm the next Area Alarm message will be displayed until all Area Alarm messages have been acknowledged or postponed The display will then show the Area Status display to allow you to continue with your operation e g Turn the Area OFF Acknowledge Reset Latched Alarms Input alarms are latched If this message is displayed certain types of alarms in your system have been programmed to Latch Admin Latching alarms enables all alarms in an Area to be is On individually viewed Refer to the Concept 4000 User Manual for details CONCEPT 4000 Prisma Colour Graphic Terminal User Manual 17 Access Unlock a Door Prisma Terminals may be programmed to momentarily Unlock a Door to allow access 2 2 Logon to the Terminal as described earlier md Ma gt J PIN lt OK gt Area Status will display as before Press the lt OK gt key a second time to Un lock the OK J Door If necessary See note below NOTE For any Terminals or Users designated as Access Only No Area Control or Menus the Door now unlocked message will be displayed after PIN lt OK gt is entered as this is the only operation required to unlock a door in these circumstances The disp
6. Tamper monitoring part of the Area to be turned ON or OFF Normally restricted to Installer amp or Owner 27 ARROW KEYS AND SCROLL WHEEL gt The SCROLL WHEEL or the UP and DOWN arrow keys are used to scroll up and down through lists of available items to view control or program e g Areas Zones Review messages etc and to adjust numerical values e g Home Auxiliary Timer The Scroll Wheel can also be used to move the cursor left or right The LEFT arrow key will move the cursor to the left The RIGHT arrow key will move the cursor to the right OR if pressed when not logged on may display Home Auxiliary control options if enabled CONCEPT 4000 Prisma Colour Graphic Terminal User Manual 5 The lt OK gt key must always be pressed after you have d entered your secret PIN code Unless performing a Quick Arm or Disarm operation You have 10 seconds to press the lt OK gt key after you have completed entering the code OK If PIN codes are used to unlock doors pressing the lt OK gt key again will perform the Door unlock operation on the Door associated with the Terminal On Terminals that are programmed ONLY for Door Access control the lt OK gt key may not need to be pressed twice In some cases the lt OK gt key may be programmed to unlock a door without a PIN code being used e g In low security periods or when the Terminal is on the inside of an Exit Door OFF ON Used to
7. ad Functions in th Menu ous osetsacsotatites iore depou tonus cRe cer ubs pH e esae snp aes 23 CONCEPT 4000 USER MENU FLOWCHART 4e 24 INNER RANGE recommends that all CONCEPT systems are installed amp maintained by FACTORY CERTIFIED TECHNICIANS For a list of Accredited Dealers in your area refer to the Inner Range Website http www innerrange com Disclaimer While every effort has been made to ensure the accuracy of this manual the manufacturer and or it s agents assume no responsibility or liability for any errors or omissions Due to ongoing development and product improvements the contents of this manual are subject to change without notice CONCEPT 4000 Prisma Colour Graphic Terminal User Manual 3 The Keypad Operations amp programming are performed by using the function keys fixed keys and scroll wheel Each time a key is pressed a short beep will be emitted to indicate that the key press was accepted The Installer can disable the beeping if necessary If the Terminal emits a long beep it means that the key press was not accepted or is not allowed You may only press one key at a time Function keys E Scroll wheel and one we up down left amp right arrow keys Sl ERE ON OFF keys fasc DEF San o 4u 5mno ron o Alpha numeric keys Ten 8vwx 9vz E END key END 0 HELP HELP key FUNCTION KEYS The operation of these ke
8. form the Area OFF or ON operations Remember You have a limited time to turn an Area OFF once you have entered the Area Usually 30 90 seconds Ask the Installer for the Entry time used in your system EN EU 2 2 OK Area Control Admin Sales Counter Board Room Training Room Menu Press Off Area Lists Logon to the Terminal as described earlier PIN code lt OK gt After the greeting if enabled the display shows the Area Status etc as before The currently selected Area 1s highlighted To select another Area see AREA SELECTION below Turn the displayed Area or Area List OFF by pressing the OFF key The icon and text colour will alter accordingly to indicate that the operation was successful NOTE Quick Arm Disarm Your system may be configured to allow a nominated Area to be controlled simply by entering your PIN code then the OFF or ON key i e OK key not required OE O AREA SELECTION You may select other Areas by using the SCROLL WHEEL the UP DOWN Arrow keys and or the lt DIGIT gt keys to select the Ist letter that the Area name begins with e g A system has Areas named Reception Research and Rohans Office 1 To select any of these Areas press the lt 6 PQR gt key until an Area starting with R is displayed You may need to press the key between 1 and 3 times CONCEPT 4000 Prisma Colour Graphic Terminal User Manual 11 2 If the A
9. he Top of the display will show the selected alarm review event in full The Lower part of the display will show the first part of the four most recent alarm review events The SCROLL WHEEL or UP and DOWN arrow keys will step to the previous alarm or next alarm respectively Press the Exit or END key to return to the normal display See MENU OPTIONS for details of how to view all types of Review Events REMEMBER Any time you need it HELP iS as close as the press of a key CONCEPT 4000 Prisma Colour Graphic Terminal User Manual 19 View System information This option allows Users to view a range of System Information such as Serial Number Firmware Version Hardware Type and Memory options without needing to Log on to the Terminal The Installer or Monitoring Station may ask you to provide information from this Menu from time to time particularly if new features or upgrades are being planned To access the System Information simply press the lt Menu gt FUNCTION key highlight the Info icon using the SCROLL WHEEL then press the lt OK gt key The display will show the first of three System System Info Information screens SN 195001 Vers F08 00 Build 01 PCB 2 Ram 128K 05 08 00 Country AU Disty XX Cust 000 The UP and DOWN arrow keys will step to the previous screen or next screen respectively Press the END key to return to the normal display END
10. heir secret PIN code followed by the OK key When this is done the system verifies the User and depending on the operations allowed the User is then able to select another key to press to perform the operation required The LOGON procedure is described on the following page Common operations are then described in detail Level Messages System operation is continuously monitored for problems and special conditions A Level Message is displayed on one or more of the Terminal s if such a condition exists and will remain on the LCD display until the condition is rectified You will probably need the Installer to rectify any of the first 4 conditions MESSAGE DESCRIPTION Had Power Problem One or more Modules have lost AC power If accessible check AC power cord plug pack is connected amp switched on Had Battery Problem One or more Modules have low battery voltage Had Network Problem One or more Modules are not communicating with the Control Module There may be cable damage or a Module problem Had Comms Problem There is a problem with one or more Comms Tasks e g Central Station PC Printer etc Alarm reporting may be compromised Some Inputs latched isolated See Acknowledge Latched Alarms and View Input States in the tampered unsealed Concept 4000 User Manual lt MEN U gt 1 lt 5 gt Area about to turn On See Turning Area s Off Deferred Area Arming Option Area Name Enter Code See Menu
11. l 13 Turning Area s ON IMPORTANT NOTE Some systems in high security applications may have the Pre Arm Walk Test feature enabled In most systems this feature is not enabled and the Area ON procedure will simply be performed as described below If Walk Testing is enabled on your system the same procedure is followed except that after the initial test to ensure that all Zones are Sealed the system then enters Walk Test mode Refer to Area Walk Testing in the Concept 4000 User Manual gt D O Q 2 2 Logon to the Terminal as described earlier 33 7 30 PIN code lt OK gt After the greeting if enabled the display will show the Area Status etc as before The currently Area Control amp Sales Counter selected Area is highlighted Another Area can be E selected as described in Turning Area s OFF Board Room If you are allowed to control more than one Area amp Training Room or the 24 Hour Tamper part of an Area the DISPLAY MODE can be changed as described in Menu Press On Area Lists Turning Area s OFF Turn the displayed Area or Area List ON by un pressing the lt ON gt key See Quick Arm Disarm under Turning Area s OFF for additional information Display briefly shows After the lt ON gt key is pressed the system will test the state of all the inputs allocated to the Area Testing Zones to ensure that they are in the Sealed condition and Please Wait the Area is
12. lay will verify that the operation was Door now successful or indicate why the operation could not Un locked be performed Access may be denied if the Area is ON or User s TimeZone is not valid etc gt 3 gt O Card PIN In some Door access or Lift Floor selection applications presentation of an Access Card must be followed by entering your PIN code at an associated Prisma Terminal before Access is granted SS3J00V After presentation of the Card the Terminal will Please Enter display a prompt for the PIN code Pin Now Enter your PIN code followed by the OK key EE mU OK The Door will un lock and the LCD will return to ete ett the normal display Door now unlocked will not be shown 18 CONCEPT 4000 Revision 2 0 May 2012 SYSTEM STATUS AND CONTROL OPERATIONS View Alarm Review information Individual Terminals may be programmed to allow Users to review recent Alarm information without needing to Log on to the Terminal y Review Review Apr22 17 57 09 4 Alarm on Temperature Sensor 3 Apr22 17 57 09 4 Alarm on Temp Apr21 08 07 39 6 Alarm on PIR S Apr07 14 21 28 7 Tamper on Doo Apr01 19 42 51 8 Isolate on PIR N If this option is enabled simply press the lt Menu gt FUNCTION key highlight the Review icon using the SCROLL WHEEL then press the lt OK gt key The display will show the most recent alarm events recorded in the Review memory T
13. lour Graphic Terminal User Manual 21 Controlling the Home Auxiliary When the desired Home Auxiliary is selected i e Highlighted in the list press ON to turn the Auxiliary On OFF to turn the Auxiliary Off lt OK gt to toggle the Auxiliary state Exit or END to return to default display or Timed On FUNCTION key to enter a Home Auxiliary On time If Timed On is selected use the LEFT and or RIGHT ARROW keys to position the cursor on the time digit you wish to edit then use the SCROLL WHEEL or the ALPHA NUMERIC keys to enter the required value A period of up to 4 Hours may be entered Periods of 1 to 255 seconds 4 minutes amp 15 seconds are accurate to 1 second Periods over 255 seconds are accurate to 1 minute When the timer period is entered press lt OK gt to execute the timed action or lt Cancel gt The display will then return to the Home Auxiliary list The icon and text will be updated to indicate the new Home Auxiliary state This message will appear if you attempt to control a Home Auxiliary that can only be controlled when you are logged on e g via lt Text Menu gt lt 9 gt lt I gt or is not allowed in your User Type permissions C O Z mr JJ O 22 CONCEPT 4000 Revision 2 0 May 2012 MENU OPTIONS Users with an appropriate level of authority can perform many other operations and are allowed access to certain programmi
14. ming or viewing Operations in the menu are described below UP and DOWN ARROWS Scrolls up and down a list of g P available items to view program or control e g Users Zones 4 Review messages amp Home Auxiliaries LEFT ARROW Moves cursor left or selects previous question for the same item if the cursor 1s at the start of the field RIGHT ARROW Moves cursor right or Scrolls through the options in multiple choice questions Switches between different modes for selecting an item or answering a question e g Provides option of selecting an item by ID no Zone E01 Z03 or by name OFFICE PIR or If entering text changes the last letter entered to lower case Clears the screen for entering new text etc or Selects first option in multiple choice questions Saves the current screen amp moves to the next question or Executes OK i 7 an operation 5 9 When programming questions that require a Yes No answer the ano 77 N 5 key selects No and the Y 9 key selects Yes 2 The lt DIGIT gt keys are used to select an item or option by number 2 m or ID and for programming text or numerical values where available User names Card numbers Door List names etc EM Saves the current screen exits the menu and logs the User Off Provides relevant help messages on the display whenever required HELP e g Will tell you what to do next if you are unsure LdO fIN3IN CONCEPT 4000 Revisi
15. mpt you to press the lt HELP gt Press HELP key again if you want to activate the Panic alarm again for panic Press the lt HELP gt key again within 10 seconds to activate the Panic alarm OR Press the lt END gt key to abort if you pressed the Help key a second time accidentally HELP or END The display may show an alarm message or may simply return to the normal display depending on how the Panic alarm is processed Activating a Duress Alarm Your system may be programmed to allow a Duress alarm to be activated if you are being forced to perform operations at a Terminal against your will Duress is activated by simply entering a special PIN Code instead of your normal PIN Code when logging on to the LCD Terminal Refer to the Concept 4000 User Manual for details y Q O Og D o o 16 CONCEPT 4000 Revision 2 0 May 2012 Acknowledge an Alarm Alarm messages must be acknowledged by a User with the appropriate authority These messages provide precise information of the type of alarm the Area it has occurred in and the Zone or System Input that generated the alarm An Alarm message may be displayed on the Terminal indicating which Area the Alarm has occurred in Had Alarm in Kitchen Admin is On Logon to the Terminal as described before s 355 ies PIN code lt OK gt The display will show the specific details of the Area Alarm Alarm Had Alarm on
16. ng facilities via the Menu A Menu Flowchart showing all the User Options can be found on the back cover Refer to the Concept 4000 User Manual for details of all User Menu options Accessing the Menu 2 2 Logon to the Terminal as described earlier 73 45 9j PIN code lt OK gt The display will show the Area Status etc as before Now press the MENU key The Menu key can be used whenever shown to return to the Main menu The display will now show the most commonly used Menu options via icons Options that you do not have permission to access will be greyed out e g Installer Menu Use the SCROLL WHEEL or ARROW keys to highlight the required option then press OK To view the full User Menu press the Text Menu key Main Menu The display will now show all of the Main User Menu Area On Off options User programming will determine which Info 2 Access options will be available Isolate Testing 5 Times Misc 8 Service Control Press a lt DIGIT gt key to select a Main Menu option 0 1 3 4 6 9 The display will then show the selected operation or a Sub Menu selection screen Some options e g User Codes Review amp Time Date setting require another digit or two to be pressed e g User Codes 2 1 Door Lists 2 3 2 Review 1 1 CONCEPT 4000 Prisma Colour Graphic Terminal User Manual 23 Keypad Functions in the Menu The functions of the keys while performing control program
17. no specific Default Display option has been chosen the Concept 4000 logo will be displayed E Library is Off Menu Temp 25 3 C Log On Admin Kitchen Bistro Public Bar Bottle Shop Cellar Cool Room Band Room Monday 18th Apr 11 25am E Library is Off SINGLE AREA STATUS This option allows the name and current status of a single Area to be displayed This is useful when the Terminal only provides control of one Area MULTIPLE AREA STATUS The Multiple Area status screen allows the current status of 8 Areas to be viewed by name The icon against each Area name indicates the current status Off Disarmed On Armed Timed Off Defer Arming timer running or Defer Warning Timer about to expire See Turning Areas Off for details of the Defer Arming feature TIME amp DATE Allows the current system Time amp Date to be displayed This is useful in systems that generate Time On Site reports providing a display of the actual system Date amp Time being logged Time amp Date display is at the bottom of the screen if the Multiple Area Status option is selected CONCEPT 4000 Prisma Colour Graphic Terminal User Manual T Monday 18th Apr 11 25am CUSTOM MESSAGE The Diaries feature can be utilized to provide a EL Library customized message that is appropriate for the is Off particular Site and or the particular Terminal Some common applications are The Monitoring Station s Telephone number
18. on 2 0 May 2012 24 Kay n fo ssa4d ay sp asoj sp s1 IaH 1 paau nok amy amp uy i WAIIWANAN Part Number 635060U T 6 lt NUIN 1x9 gt 03u00 100q I p T lt nuapy IXI L gt sdnoJrc nuoJA T S lt NUIN 1x9 gt sSouozouln 5 9 19M0d peeu 9 Aseuwy g sejeis Indu G juno Jes Z Ajuo edoin3 1 juno peeH y ouy peeu juno2 1U9 3 9 nue Sdnoit y SAepl OH Je uns sist Jody SOUOZ OUI Z 1000 Z sed 1SN Z SJOS Ne u09 47 v leo Jemsuy y lesf eje201 Z uoo 100q Z uodeg ise Z M N l1esed Mn c RENE e qesiq IMPON xny euloH Mas beu malAey NI 0 ayeq aul aul g fsal sem v aosi c IOUO 6 99IMeG g snoeue 99sl N 9 UOIJeUUJOJU suondo nuaur qns qng sjopioq sure So suondo nuour qng SIopioq RPULION uobo1 suondo nuo urey pue oouonbeos uoSo T SIop1oq pog if H Comments relating to this manual should be sent to publications innerrange com nue 8p09 Nid 2011 2012 Inner Range Pty Ltd JABYPMOTT nuo A 19S 000p 13d92uo
19. rea that you require is not displayed use the DOWN Arrow key to scroll through and select another Area starting with that letter Note Areas are sorted numerically after the Ist letter DISPLAY MODE If you have permission to turn ON amp or OFF More than one Area The 24 Hour Tamper part of an Area gt D O Q 24 Hour The Display mode can be toggled between AREAS AREA LISTS and 24 HOUR by pressing the right hand FUNCTION key Once in the selected mode Area Area List selection and control is the same as described previously Please read additional information below AREA LISTS Allows you to turn OFF all the Areas in the selected List that you are allowed to control with a single operation 1 e You can select any Area List in the system However only Areas that are in the Area List selected and are also in the Area List in your User Type or your Extra Area will be turned Off 24 HOUR Allows the Installer or a User with the appropriate level of authority to turn the 24Hr part of an Area Off so that maintenance or changes can be performed on equipment or devices detectors etc in the system The 24Hr part of an Area continuously monitors the equipment and inputs for faults or deliberate interference and activates Tamper alarms when these conditions occur Note that most Users in the system will NOT have access to this operation Note When the 24 Hour monitoring is
20. ready to be turned ON then THEN If all Zones programmed to be tested are Sealed Admin the Area will turn ON and this display will now On indicate that the operation was successful 14 CONCEPT 4000 Exit Delay Time until arming of Admin Admin Zone in Alarm Fire Door Reed Switch Isolate Ete Fe NOTE Revision 2 0 May 2012 While the Area now On message is displayed You can press the lt ON gt key again to view the Exit delay time counting down Remember You have a limited time to exit the Area once you have turned it ON Usually 30 90 seconds Ask the Installer for the time used in your system When the operation is complete the display will return to the Area status display The icon and text colour will alter accordingly to indicate that the operation was successful OR After pressing the lt ON gt key the display may show a message like this It means that the item displayed is either in an alarm state or faulty and the Area will not turn ON e g A detector or it s cabling have been damaged A door or window has been left open Try to rectify the problem before trying again If this is not possible you may be allowed to ISOLATE the item while the Zone Problem message is displayed Press the lt Isolate gt key then lt OK gt to confirm the Zone Isolation operation or press lt Abort gt to cancel the Area On operation Inputs isolated in this way are au
21. tomatically de isolated when the Area is turned OFF Display Counters In some special applications after the Area ON message the display will automatically show the Read Counters screen This allows the User to view the results of any automatic or manual testing of devices that have an event output monitored by the system Refer to the Concept 4000 User Manual for details CONCEPT 4000 Prisma Colour Graphic Terminal User Manual 15 Activating a Panic Alarm Your system may be programmed to allow a Panic alarm to be easily activated from any Terminal without needing to Log on A Panic Alarm is activated by simply pressing the HELP key three times in a row When a Panic alarm is activated the resulting action will depend on how the optional Panic System Inputs are programmed for each of the Terminals in the system e g In some sites Panic may be required to activate local Sirens and send a report to a Computer in a local Control Room In other sites Panic may be treated as a Silent system alarm with a report sent to a remote monitoring station and no local action at all IMPORTANT NOTE Consult your Installer to detemine if the Panic function is enabled and how it will operate in your system Press the HELP key at any LCD Terminal that HELP ars has the Panic option enabled The display will show the normal logon help message Press the lt HELP gt key again within 60 seconds HELP The display will pro
22. turn Off or turn On the Item named MER ici on the Display at the time e g Area Area List Home Auxiliary etc ALPHA NUMERIC keys Used for entering your secret Tasc PIN code You have 10 seconds to enter each digit and must press the lt OK gt key when complete This sequence is required before most panel operations can be performed These keys can also be used to search for an item to be controlled by selecting the first letter of it s name HELP HELP Can be pressed at any time and displays a Help a message about the current operation being performed The lt END gt key is used when you have finished EN performing the required operations NOTE Keypad keys also have other functions when you are selecting viewing controlling or programming items in the menu Details of the keypad functions when you are in the menu are provided in the Menu Options section of this manual The system may be programmed to limit the operations available at some Terminals 6 CONCEPT 4000 Default LCD Display Revision 2 0 May 2012 The Prisma Terminal offers a number of options for the Default display This is the display that will be shown when there are no User operations being performed and no Alarms or other messages to be displayed The Default display can be selected separately for each Terminal in your system The settings can only be programmed by the Installer who can also advise you on the appropriate options If
23. turned Off in an Area it will automatically be turned back On again when the Area is turned ON to ensure that Tamper monitoring is not compromised If the Area was already Off when the 24Hr monitoring was turned Off the Area must be turned back on again before 24Hr monitoring will be re enabled 12 CONCEPT 4000 Deferred Arming option Revision 2 0 May 2012 In some applications the system is programmed so that certain User types may only turn the Area Off for a limited time e g A cleaner or guard working outside normal working hours may only turn the Area Off for 60 minute intervals LO EE 2 oe tite Cellar about to turn On A Admin is Off When these User types turn the Area Off the icon shows Area is Off with a Defer timer running At any stage during the defer time the User can Turn the Area Off again to re start the timer or Turn the Area back On and cancel the timer When the timer has only 250 seconds left to run the Terminal will beep every 2 seconds and display this warning The User can still perform the Area Off or Area On operations during this warning period but 1f no action is taken the Area will automatically turn On when the warning period expires NOTE If more than one Area is about to turn On the display shows each Area in turn for 2 seconds REMEMBER Any time you need it HELP iS as close as the press of a key CONCEPT 4000 Prisma Colour Graphic Terminal User Manua
24. ys will change according to the screen currently in use e g Left Key Menu Text Menu Cancel Exit Right Key Log On Config Delete Area Lists 24 Hour Areas Timed On lt MENU gt Accesses the Menu for information and operations other than Area On Off Door Access etc A limited Menu will be displayed if you are not logged on lt Cancel gt Allows you to cancel a PIN code entry without logging an attempt e g If you make a mistake and want to start again 4 CONCEPT 4000 lt A Delete Revision 2 0 May 2012 lt Text Menu gt Once in the Menu allows you to switch between an Iconic menu and a Text menu Due to limited screen space for display of icons the text menu usually offers addition menu options lt Exit gt Exit to the default display lt Log On gt Displays the Logon screen lt Config gt Once in the Menu allows access to the user configurable Prisma Terminal options such as colour schemes backlight levels and speaker volume etc The Config function key will only be displayed for Users with permission for the Users Access or Times Menus lt Delete gt Allows you to delete the last character entered e g If you make a mistake while entering your PIN code Area Lists 24 Hour Areas When in the Area control screen alternative Area control options will be presented on the right hand Function key Note 24 Hour allows the
Download Pdf Manuals
Related Search
Related Contents
ファイル名:25joho_seikyuuichiran3 サイズ:824.23 KB Manual - TMG Test Equipment Circuit électromécanique Modell 2500 Fixed Disk Drive Service Manual / Century Data Txx Installation Instructions - Northern Tool + Equipment Tesis Faretti direzionali Istruzioni per l`uso DELL Precision M6800 Model S – First Responder Guide 2012/13 los proyectos hacen los objetos eternos, las modas los User`s Guide for Version 6.0 Copyright © All rights reserved.
Failed to retrieve file