Home
Installation and Operation Manual for Stainless Steel Knee Operated
Contents
1. 2003 the manufacture Doc ref SPPL WB KO Specification nstallation and Operation doc Revision Date 11 11 2011 Page 2 of 4 STODDART Specification Installation and Operation MANUFACTURING Stainless Steel Knee Operated Wash Basins STAINLESS PLUMBING PRODUCTS I NSTALLATI ON OF KNEE OPERATED WASH BASI NS Water Supply Requirements e Water supply connection for the valve must be 15mm diameter e All Stoddart wash basins are fitted with a 40mm waste Installation of Knee Operated Wash Basins Removable All Stoddart basins are supplied with mounting holes pre punched for easy Mounting installation bracket e Remove the packing from the wash basin and check for Screws damage e Remove access panel e Unscrew the screws on either side of the basin to remove the removable galvanised bracket from the basin e Place the bracket at desired height and mark the locations of screw holes and or outline around the bracket if adhesive is being used making sure bracket is level e Ensure the water supply and waste are in the zone marked in the image to the right and the waste is approximately 673 85mm above FFL for 900mm basin height mounting bracket e Attach bolts with sufficient load bearing fixings to the wall e Fix the removable bracket to the bolts e Slide the wash basin on to the bracket ne ae e Tighten the flexible coupling fasteners and replace the screws on either side of basin ae e Repl
2. STODDART Specification Installation and Operation MANUFACTURING Stainless Steel Knee Operated Wash Basins STAINLESS PLUMBING PRODUCTS Installation and Operation Manual for Stainless Steel Knee Operated Wash Basins This manual is suitable for the following models Standard Height Models KNEE OPERATED WASH BASIN SPPL WB KO1 Knee Operated Wash Basin Type 1 SPPL WB KO1 300 Knee Operated Wash Basin Type 1 300mm Splashback SPPL WB KO1 TV Knee Operated Wash Basin Type 1 Tempering Valve SPPL WB KO1 300 TV Knee Operated Wash Basin Type 1 300mm Splashback Tempering Valve ae ca ae as SPPL WB KO3 Knee Operated Wash Basin Type 3 SPPL WB KO3 TV Knee Operated Wash Basin Type 3 Tempering Valve Doc ref SPPL WB KO Specification nstallation and Operation doc Revision Date 11 11 2011 Page 1 of 4 STODDART Specification Installation and Operation MANUFACTURING Stainless Steel Knee Operated Wash Basins STAINLESS PLUMBING PRODUCTS CONTENTS RECONMENDATHON G Toena E AEE ica nei E can E E AA EAA 2 RE PO SVB EET I ES roeren A N E E E meas tonsa yaad ate A E E A 2 REFERENCED AUSTRALIAN STANDARDS ccccccceecccceeeeceeeeeeeee sees eeeeeeeeeeeeeeeeeeeaeeeeeseeeeseaeeeaeeeeeaeaeeeseaseeesaaseeeseasetsaeessaagess 2 INSTALLATION OF KNEE OPERATED WASH BASINS cccccceccccceecceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeeeeeaeeseeeaeeseeaaeesenaeess 3 Water SUPPIY COIS II SNS ctr ceacttaar acres
3. ace access panel Ce a oy eS e Clean stainless steel surfaces p Note Protect the product at all times by wrapping in plastic until all other work is complete and the system ready to be put into operation SAFETY PRECAUTI ONS For the installation and operation observe all relevant electrical safety plumbing and building standards All supplied components should only be used for the purpose they are designed for 900 waste height TROUBLESHOOTING Unit will not stop water flow or leaks from outlet Check to see if a line strainer is installed And make sure there is a 2mm gap between push rod and push panel If a line strainer is not installed then check for dirt and grit and clean valve cartridge f above checked out o k contact service Unit water flow from outlet is too little e Check distance between push rod and push panel Make sure there is a 2mm gap by adjusting push rod e Check supply pressure and stopcocks are open e Check lines are not flattened Cannot Find the Bracket Bracket is supplied and installed in unit Locate galvanised steel bracket on rear Locate screws on either side and unscrew bracket from body FFL INLET HYDRAULIC CONDITIONS Min flow pressure 200 kPa Max flow pressure 500 kPa Min connecting pipe size 15 mm copper Max static pressure 800 kPa Refers to the minimum connection pipe size to any valve branched off the ring main pipe providing that the ab
4. ane tase eeutentmennbantminetined nied secs ANON EERE OKETE EE EER 3 Installation of Knee Operated Wash Basins iscsi ccc nticdccusntaclvansetnbeanetcuarwesiderweeiwerswaeeeuwen rama dsuoen aera meee 3 SAFETY PRECAUTIONS ccccccceeccceeeceee ee eeee ee eee eee eeeee a rrtt ttrt rr1t EEA rtrt GH EEEAGHEEEES AE EEEAGASEEAGAEEEEGAEEEESGAAESEEGAEESEG AE ESEA AE SEEEGHSESEG EEE HOES 3 TROUBLE SHOOTING einn ao E EE EOE EEEN PENE possess EOE EAEE EEE NEEE EE EE EEEE EEE EEES PENNOR ENEN ENDE 3 INCET HYDORAWLIC CONDITION eirinn irer E AEEA EEE EAE AE AR Ni 3 PARE PART oeo NEE E E E AEN EE E EEE EE 4 WARRANTY e E E E er ciaiein alae amar aanonecets 4 CLEANING IN TRUCTEON xccasrenesssacsesssetoscenue EAA ANE AEAEE NEEE EAN NEARE NENEA RE AA EAEE ENEAN A EEA SEEE EEEE 4 CUSTOMER NINO U UR stntenniaorsaurontronbiant bohirhbientebniabehnns anbvaubenideatesaiacainnatresnntenatavateaa tual ia eaeoe eeri 4 RECOMMENDATIONS Upon receiving a Stoddart product inspect immediately for any visible signs of shipping damage and notify the carrier immediately When removing the product from its packing be careful not to dent or scratch outer surface Any concealed damage should be noted and reported immediately to the freight carrier A claim should be filed with carrier if appropriate RESPONSIBILITIES Stoddart thoroughly inspect all products they are despatched from our factory Stoddart Manufacturing will not accept responsibility for shipping damage The Plumber is r
5. e or improper application or improper installation e Warranty Claims must be submitted in writing to Stoddart Manufacturing within 14 days of observation of fault e Items may be returned to Stoddart s Factory by the Customer for warranty inspection For valid warranty claims Stoddart will repair or replacement the item and return it to the Customer promptly e For installed products Photos must accompany the Warranty Claim for effective consideration e lf a site visit is required to conduct warranty repairs such work will be carried out during normal business hours e g 8am to 5pm Mon to Fri CLEANING INSTRUCTIONS All surfaces of the product should be cleaned with mild soap and water or a neutral product Carefully rinse away all surplus cleaning product IMPORTANT Never use harsh or abrasive cleaners on stainless steel Do not use chlorinated or bleach water CUSTOMER I NQUI RY All customer inquiries regarding Stoddart Stainless Steel Wash Basin s should be referred to Customer Service Department Stoddart Manufacturing 149 Jackson Road 4109 Sunnybank Brisbane Ph 61 7 33455011 Fax 61 7 33441000 Email plumbing stoddart com au Web www stoddart com au Doc ref SPPL WB KO Specification nstallation and Operation doc Revision Date 11 11 2011 Page 4 of 4
6. esponsible to ensure that the system is installed in accordance with all specific requirements of local codes and regulations including AS 3500 If questions or complications should arise during the installation of a Stoddart product that cannot be solved using the accompanying instructions please contact our offices or local representatives Note It is the Plumbers responsibility to install this product in accordance with AS3500 REFERENCED AUSTRALIAN STANDARDS Design amp fit out of Food Premises AS 4674 2004 Markings amp Labels Watermarked components must have Watermark logo and AS 3500 1 2003 license AS 5200 000 2006 Appendix B Copper alloy products marked DR AS 6400 2005 Clause 2 4 6 AS 2345 2006 Dezincification resistance Dezincification resistance applicable to copper alloy AS 2345 2006 components in contact with mains water Contamination of water Products For Use In Contact With Drinking Water AS 4020 2005 Pipes and Fittings Dimensional compliance with relevant or corresponding AS 3688 2005 Australian Standard for the pipe or fitting Joints i e Spigots sockets flanges Dimensional compliance with relevant or corresponding AS 3688 2005 7 other joint components where Australian Standard for the pipe or fitting interfacing other authorized Pipe Threads of Whitworth Form Part 2 Fastening Pipe components Threads Installation Warranty Installation instructions shall be provided by AS3500 2
7. ove required technical specifications can be met Pipe work to the valve fixture must be sized to and installed to water service rules and regulations AS NZS 3500 1 and local regulations and simultaneous demand requirements To ensure proper sizing of the pipe work for the valve it is recommended to engage a qualified hydraulic designer Doc ref SPPL WB KO Specification nstallation and Operation doc Revision Date 11 11 2011 Page 3 of 4 STODDART Specification Installation and Operation MANUFACTURING Stainless Steel Knee Operated Wash Basins STAINLESS PLUMBING PRODUCTS SPARE PARTS Article No Description CMPL 0255 Waste and Plug CMPL 0352 Valve Housing CMPL 0353 Valve Cartridge CMPL 0464 Wall Spout WARRANTY Upon receiving a Stoddart product inspect immediately for any visible signs of shipping damage and notify the carrier immediately When removing the product from its packing be careful not to dent or scratch outer surface Any concealed damage should be noted and reported immediately to the freight carrier A claim should be filed with carrier promptly if appropriate Stoddart Manufacturing will not accept responsibility for shipping damage The Standard Terms and Conditions of Sale clearly details Standard Warranty Policy Plumbing Products offer additional conditions as follows e Warranty on materials and labour is limited to 12 months from date of installation e The Warranty does not cover damage caused by abuse misus