1. USER S MANUAL SPLIT TYPE AIR CONDITIONER LLOYD ELECTRIC amp ENGINEERING LTD To avail 03 Free preventive maintenance services within 1 year of Warranty Please call us at our Toll Free No Gujarat 1800 2582 583 Maharashtra 1800 1024 212 Punjab Himachal J amp K 1800 1027 781 Andhra Pradesh 1800 1200 666 Rest of India 1800 1020 666 Dear Customer Congratulations on being the Proud owner of Lloyd Air Conditioner Your Air Conditioner comes with Lloyd Guarantee of Quality as detailedin the manual Lloyd takes great pridein providing its customers with perfect products that adheres to international quality standards Lloyd is committed to provide the ultimate customer satisfaction as nothing brings us greater joy than having satisfied customers of Lloyd At Lloyd feedback and suggestions based on your product usage experience is greatly appreciated Please contact to us at perfectservice lloydmail com Nipun Singhal President Air conditioners are pieces of high value In order to ensure your lawful rights and interests please have the professional technicians to do the installation for you This Instruction Manual is the universal purpose version for the models of split wall mounted air conditioners manufactured by our Co The appearance of the units that you purchase might be slightly different from the ones des
2. AT is for FAN When TURBO operation is selected room temperature is not controlled with operation being continually lf you feel the room temperature is too cool or too heat please cancel the TURBO operation Remote Controller 2 Temperature indicator Indicates the set temperature AUTO indicator COOLING indicator DRYING indicator HEATING indicator FANING indicator SWING indicator Indicates selected flap mode TIME indicator Indicates timer time SET TEMPERATURE button This button sets the room temperature MODE button This button changes the operation mode AUTO COOL DRY HEAT FAN FAN SPEED button This button set air rate TURBO button 4 n o fe 5 Q 3 ow J Q D n a e 4 G o J u O t fe O D y o e Q fa D a 5 gt Cc Sa O w Ps lt w a T gt Zz 3 2 D TIMER button This button is used to set the switch on or switch off and the timer time NOTE SLEEP indicator Indicates during sleep operation TURBO indicator Indicates during TURBO operation Key lock indicator FAN SPEED indicator Indicates the seted air rate ON OFF button This button when pressed starts operation and stops when repressed SWING button This button changes the flap mode natural flow swing or fixed wind AIR FLOW button optional This button used for selection o
3. FAN SPEED indicator Indicates the set temperature Indicates the seted air rate OPERATION MODE indicator indicates selected operation mode SLEEP indicator Indicates during sleep operation TURBO indicator Indicates during TURBO operation SWING indicator Indicates selected flap mode Key lock indicator SET TEMPERATURE button This button sets the room temperature ON OFF button p l 5 SWING button This button when pressed starts operation and stops when repressed AIR FLOW This button changes the flap mode natural FAN SPEED button flow swing or fixed wind This button set air rate AIR FLOW button optional This button used for selection of the left right TIMER button TURBO LAMP air flow direction whenever pressed the in This button is used to set the switch on or tiap wirewing TE JUST arouses dimensional air flow model switch off and the timer time SLEEP button TURBO button This button changes to SLEEP operation This button changes to TURBO operation It does not work in AUTO DRY and FAN mode TIME indicator Indicates timer time OPERATION MODE select button This button changes the operation mode AUTO COOL DRY HEAT FAN HOLD button Press this button to lock or unlock the keyboard NOTE Above figure shows all indications for the purpose of explanation but practically only the pertinent parts are indicated When air conditioner is cooling only model the HE
4. OS mode _ e oe Sx SWING button yoo Haee TIMER button f oe i A S This button changes the flap mode natural NNG Ema TINER This button is used to set the switch on or flow swing or fixed wind j ri S switch off and the timer time AIR FLOW button optional ef A S TC HOLD button i AIR FLOW SLEEP HOLD Press this button to lock or unlock the This button used for selection of the left right ff c keyboard air flow direction whenever pressed the in ia D a flap will swing or fix It just works on three Me A dimensional air flow model CLEAN LAMP C F CIF button RESET button O The temperature and drgree of switing This button let computer reset This button changes to SLEEP operation This button is used to set time Pa NOTE SE E n Above figure shows all indications for the purpose of explanation but practically only the pertinent parts are indicated When air conditioner is cooling only model the HEATis for FAN When TURBO operation is selected room temperature is not controlled with operation being continually f you feel the room temperature is too cool or too heat please cancel the TURBO operation Transmission procedure When each button on the remote controller is pressed with the remote controller pointing toward the air conditioner unit signal is sent When the sign
5. This is caused by the refrigerant that is circulating inside the unit Noise is heard cracking sound After a power stoppage or after disconnecting the power supply plug This is caused by heat expansion or contraction of plastics Operation can not be restarted even if the power is recovered The memory circuit of the microcomputer is cleared Operate the remote controller again to restart the operation Remote control signals are not received Remote control signals may not be received when signal receiver on the air conditioner body is exposed to direct sunlight or strong lighting In that case interrupt the sunlight or darken the lighting o Moisture may form on the air outlet grilles If the unit is operated for a long period of time with the high humidity moisture may form on the air outlet grilles and drip down LLOYD ELECTRIC amp ENGINEERING LTD Plot no 2 Industrial Area Kalkaji New Delhi 110019 Tel 91 11 47100600 Fax 91 11 26485717 Email perfectservice lloydmail com Website www mylloyd com Regd Office A 146 B amp C RIICO Industrial Area Bhiwadi 301019 Rajasthan Customer care Toll Free No Gujarat 1800 2582 583 Maharashtra 1800 1024 212 Punjab Himachal J amp K 1800 1027 781 Andhra Pradesh 1800 1200 666 Rest of India 1800 1020 666
6. air temperature is very low and humidity is very high frosting will occur to the heat exchanger of the outdoor unit which has negative impacts upon the efficiency of the heating performance In such case the automatic defrosting function will come into play The heating operation will be stopped for 5 10 minutes to do the defrosting The fans of both the outdoor and indoor units are stopped During the defrosting the outdoor unit might generate some steam It is caused by fast defrosting which is not a performance failure Upon the completion of the defrosting process the heating operation is resumed Methods of maintenance The air conditioner must be turned off and plug pulled out before the maintenance is to be carried out Before the season of operation During the season of operation The cleaning of the air filter screen Standard intervals should be once every two weeks 1 Check if there are any blocking materials in the intake and outlet vents of the indoor and outdoor units Gently press the tow lower ends of the grid and open it Gently pull up the air filter screen and take it out in the direction of your body A J LORS 2 Check if the installation stand is corroded or rusty Bie Check if the Tr machine is y terminal Je properly grounded l 4 Check if the air filter is clean 5 Connect to the power source 6 Put batteries in the remote controller 2 Clean the air fil
7. al is received correctly the receiving sound is emitted from the unit Use of remote controller OPERATING MACHINE IN SELECTED MODES 1 Point the remote controller at the unit press the ON OFF button then press the MODE button select the needed mode ATUO COOL DRY HEAT or FAN 2 Press the SET TEMPERATURE button to increase or decrease the readings until the needed temperaure is displayed The room set temperature range is from 16 C 32 C 61 F 90 F It would be automatically set at 25 C 76 F and unadjustable in AUTO and DYR mode 3 Press the FAN SPEED button to choose the air rate you want Low display indicates Med display indicates al Hi display indicates Auto display a di indicator flashing It would be automatically set at low speed and unadjustable in DRY mode 4 Press the SWING button to choose the up down air flow direction you want natural flow display indicates fi 1 Y It would be automatically set at fixed wind air flow direction in DRY mode swing displa indicator flashing fixed wind display indicates TURBO OPERATION Press TURBO button during COOL or HEAT operation the air rate can be setted in HIGH Press the TURBO button again can release the TURBO operation Note during TURBO operation the air rate cann t be changed ADJUSTING LEFT RIGHT AIR FLOW DIRECTION Methods 1 Manually adjust Adjust the direction by moving di
8. cribed in the Manual but it does not affect your proper operations and usage Please read carefully the sections corresponding to the specific model you choose and keep the Manual properly so as to facilitate your reference at later time Addition to the user manual The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance Contents Instructions to users The name of each part and its function Operation and indication sections of remote controller Use of remote controller Features of heating operations Methods of maintenance Treatment at service call We hope you will know the following when using the unit So ODwW 11 12 13 Instructions to users Please read the Instruction Manual carefully prior to the use of your air conditioner so as to ensure proper operations Instructions for Installation Make sure to have the professional after sale service persons of our company or the authorized dealers to install the units before you use 1 The units are not to be installed at places where there might be leakage of combustible gases In case that the leaked gas accumulates around the units there might occur the accident of fire hazards Make sure that the earth leakage circuit breaker is installed O Earth leakage circuit breaker Absence of the earth leakage cir
9. ctor is plugged in please make sure that there is no dust on it and that it is plugged fully in place copper wire If there is dust on the plug or if the plug is not in place it might cause electric shocks or fire hazards Try to avoid the sunlight and hot air from entering the room I m scorched During the cooling operation curtains or window blinds should be used to shade off the sunlight As the fan is in high speed operation the insertion might lead to accidents Do not clean the air conditioner with water It might cause electric shocks Do not sit on the outdoor unit or place any other objects on it The falling down of the unit or the objects might cause human injuries and other accidents Try to minimize the generation of heat during the operation of cooling Q SS Insufficient ventilation might lead t lack of oxygen or some other dangers Adjust the air direction correctly Sy A D 9 9 Z Properly adjust the up down and left right directions of the air flow so as to get the even room temperature Do not attach hang or stack articles on the air conditioner It might lead to the falling down of the air conditioner unit which will result in accidents or injuries Hot water over 40C or 104 F The use of hot water will deform the air conditioner or make it fade in color Gasoline paint diluent benzene and polishing agents etc These substances will deform the air c
10. cuit breaker might lead to electric shock and some other hazards After the connecting of the wires between the indoor unit and the outdoor unit check whether the connecting is loose or not by pulling the wire with a little force Never try to stop the operation of the air conditioner by pulling out the power supply line Such performance might cause electric shocks or fire hazards Do not operate the switch by wet hands It might cause electric shocks The grounding wire on the air conditioner should be tightly connected to the ground of the power source Improper grounding might cause electric shocks or other hazards Do not connect the power supply line to an intermediate connector Use of prolonged power line is strictly forbidden Nor is it allowed to share the same plug connector with other electric appliances Do not press stretch damage heat or modify the power line D It might cause electric shocks overheating fire hazards etc If the power line wire is damaged or needs to be replaced due to some other reasons please make sure to have dealer or the authorized It might cause electric shocks overheating 5 maintenance people to do the replacement fire hazards or other accidents Never use the fuse with incorrect capacity or any other metal wires The use of metal or copper wires for fuse might cause operational failures or fire hazards Before the conne
11. f the left right air flow direction whenever pressed the in flap will swing or fix It just works on three dimensional air flow model SLEEP button This button changes to SLEEP operation HOLD button Press this button to lock or unlock the keyboard Above figure shows all indications for the purpose of explanation but practically only the pertinent parts are indicated When air conditioner is cooling only model the HEATis for FAN room temperature is too cool or too heat please cancel the TURBO operation When TURBO operation is selected room temperature is not controlled with operation being continually If you feel the Temperature indicator Indicates the set temperature Remote Controller 3 SLEEP indicator Indicates during sleep operation TURBO indicator Indicates during TURBO operation Key lock indicator FAN SPEED indicator Indicates the seted air rate ON OFF button This button when pressed starts operation AUTO indicator COOLING indicator DRYING indicator HEATING indicator FANING indicator N MODE button 1 This button changes the operation mode s and stops When repressed C A ae AUTO COOL DRY HEAT FAN M gq CA SET TEMPERATURE button FAN SPEED button Me O J This button sets the room temperature This button set air rate PaF Pe y A TURBO button This button changes to TURBO operation en It does not work in AUTO DRY and FAN
12. hing on the machine The timer can make the setting in the range from 1 24 hours Every the button is pressed indication change is the following sequence A OPN n 24 cancel no indication 1 3 After the setting of the timed switch on the digits shown on the display screen will go down by 1 for every elapsed hour The displayed digits indicate the remaining time prior to the timed switch on D Releasing procedure When the indication on display screen is 24 hour press the TIMER button again to delete the timed mode SLEEP OPERATION Use this mode to reduce operation sound when sleeping etc Press the SLEEP button the air flow sound from the indoor unit is decreased Press the SLEEP button again can release the mode NOTE Use the sleep mode when you are going to bed lf this mode is used in the day the capacity is reduced since the ambient temperature is too high COOL MODE During the operation of cooling the room temperature will be raised gradually by 2 C 4 F higher than the setting after the machine begins to operate in the sleeping mode During the operation of heating mode the room temperature will be dropped gradually 5 C 9 F lower than the setting after the machine begins to operate in the sleeping mode REPLACEMENT OF BATTERIES When the signal from the remote controller becomes weak and the indoor unit can not receive it properly or the indications on the display screen becomes blurred p
13. lease slide the back cover and replace with S We the KAN bao 7 ORR M amp Co ve Remote Controller 1 C CLK button _ two new batteries een Daton It does not work on this model The positive and negative poles must match the installation positions ole RST buton New batteries of the same type have to be used for replacement la This button let computer reset push the RST button with the tip of a If the remote controller is not to be used for long time take out the ball pen etc batteries so as to prevent the leakage of the electrolyte from damaging oe the controller F Unload the back Cover If when the remote controller is at abnormal state you can take out the batteries on the back cover to clear off the display Remote Controller 2 Features of Heating Operations Basic principles and performances The machines absorb heat from the outdoor air and transfer it indoors so as to heat the room air The heating capabilities through this principle of heat pump go up down with the increase decrease of the temperatures of the outdoor air It only needs a fairly short time for such hot air circulation system to raise the room temperature When the outdoor air temperature is very low the system can be used together with other heating devices But good ventilation should be maintained to ensure safety and prevent accidents Defrosting When the outdoor
14. ng temperature timer time and malfunction code indicator Indications of unit 11 Indications of unit 12 Running indicator Indications of unit 13 Running indicator Timer indicator Sleeping indicator Receiver of remote controller signal Receiver of remote controller signal Setting temperature timer time and malfunction code indicator Above figure shows all indications for the purpose of the explanation but practically only the partinent parts are indicated The indicator may be changed but it does not affect your operation Setting temperature timer time and malfunction code indicator Operation and indication sections of remote controller Attention 1 The appearances of the following two remote controllers will vary out the functions of the same button are same Please check to refer the instructions for the identical remote controller of your air conditioner 2 The remote controller 1 and remote controller 2 are the general one used for many types of air conditioner in our company we beg your forgiveness that we would not introduce the button or indicator which is not applicable for units you purchased The LAMP and CLEAN button are applicable for special latest developed new models only instead of normal models The AIR FLOW button is an optional function button it just works on those models with three dimensional air flow function Remote Controller 1
15. oise and power consumption increased Therefore the air filter screen should be cleaned regularly Treatment at service call Please check the following before requesting after sale service from your dealer The air conditioner does not operate at all Is the time set to ON position a Is the power plug in an outlet Is there a power failure or a blown fuse Are the air filters clean Not clogged EO Is the room temperature setting suitable suitable TEMP NY Are the window s and door s opened Is there a heat source in the room AY EANN r Is direct sunlight entering the room Ez Are there too many people in the room Fuse or breaker often breaks off Fuse offen _ breaks off Malfunction is observed TV radio or other devices Covering of power plug or code is broken Abnormal noise is heard during operation When faulty operation movement is observed when the RUN button is pressed even after pulling out the power pulg and restarting the operation after 3 minutes faulty movement does not disappear f R 3Minutes go by F but why io es The unit can not be restarted just after shut down RUN lamp is illuminating a Not operate g P i We hope you will know the following when using the unit Restart is s
16. onditioner or cause scratches Instructions for Removal and Repair Do not use combusting apparatuses in the air conditioned room It might lead to the incomplete combustion of these apparatuses Prior to the maintenance of the air conditioner please cut off the power supply first Never do the cleaning of the units when the fan is in high speed operations s lt Do not keep exposed to the cool air for long time It might cause discomforts of the body which is harmful to your health Check the supporting structures of the units carefully In case of damages the supporting structures should be immediately repaired so as to avoid falling down of the unit which might cause human injuries or other accidents Pull out the plug when the unit is not in use for long time so as to ensure safety When the plug fs to be pulled out make sure that the switch of the air conditioner is turned off When removal or repair is needed please contact the dealer or authorized maintenance amp installation people In case of any abnormal occurrences smell of burning please stop the operation at once cut off the power supply and contact the dealer or authorized maintenance people The name of each part and its function Because there are many models features and appearance will vary we only introduce the follow pattern Others please refer to using Indoor Unit Operational performance indications Ai
17. r return grid Takes in the indoor air Indications of unit 1 zm RUN TIMER Cie O po O Lelf right air flow direction Setting temperature timer time adjusting fin and failure code indicator Up down air flow direction adjusting flap Indications of unit 2 TURBO operation indicator Setting temperature timer time and malfunction code indicator Running indicator J Receiver of remote controller signal Air inlet S Refrigerant piping at sides amp rear surface connection Electric wiring cord UU Air outlet Air blows out from here Air filter Removes dust or dirt out of the inlet air Drain tube Drain the water dehumidified out of the air Outdoor Unit Air discharge vent How to close Push down the air inlet grid and then push both sides of air inlet grid at the bottom Unit operation section H O O O O D 5 A ld Emergency operation key Lightly push both sides of the air inlet grid at the This button can be used as an emergency measu
18. re to turn on off bottom and pull it to this side till a resistance is felt unit when remote controller is not available S Note Do not open the grid at an angle over 60 degrees Do not operate the units with too much force Indications of unit 3 Receiver of remote controller signal Turbo operation indicator Running indicator Indications of unit 6 Receiver of remote control signal Setting temperature timer time and malfunction code indicator Running indicator Setting temperature timer time and malfunction code indicator Running indicator Sleep indicator Sleep indicator Setting temperature timer time and malfunction code indicator r unning umer TURBO operation indicator indicator indicator Receiver of ata Saige e SLEEP remote control O O indicator signal Setting temperature timer time and malfunction code indicator Receiver of remote control signal Indications of unit 8 Setting temperature timer time and malfunction code indicator Indications of unit 9 nem Heating indicator Flap swinging Dehumidifing Cooling cooing and Auto mode Sleeping Timer time indicator indicator indicator heating model indicator indicator indicator Setting temperature and malfunction code indicator Fan speed indicator Indoor fan motor running display Indications of unit 10 Fan speed indicator Setti
19. rectly the left right air flow direction adjusting fin by hand Caution when adjust the direction stop air conditioner Methods 2 Horizontal amp vertical auto swing three dimensional air flow model Adjust the direction by remote controller Press the AIR FLOW button the air swinging fins will constantly make the left right swinging or fixed direction in air delivery TIMER OPERATION Set turning off time Set the time for the unit to turn off and when it is time the air conditioner will automatically stop operating 1 During the operation of the air conditioner press the TIMER button and the air conditioner will enter the timed switch off mode 2 Continuely press the TIMER button to set the needed time for switching off the machine The timer can make the setting in the range from 1 24 hours Every the button is pressed indication change is the following sequence 1 2 aac 24 cancel no indication 1 3 After the setting of the timed switch off the digits shown on the display screen will go down by 1 for every elapsed hour The displayed digits indicate the remaining time prior to the timed switch off Set turning on time Set the time for the unit to turn on and when it is time the air conditioner will automatically start operating 1 When the air conditioner is in the standby mode press the TIMER button and the air conditioner will enter the timed switch on mode 2 Continuely press the TIMER button to set the needed time for switc
20. ter screen if the screen is very dirty please use lukewarm water about 30 C or 86 F to clean it Air it dry after the cleaning Note Do not use boiling water to clean the screen Do not bake the screen dry over a fire Do not exert too much force in pulling and stretching the screen Install the air filter screen To operate the air conditioner without the air filter screen on will cause the interior of the machine dirty which might lead to poor performances or damages to the units Clean the air conditioner Use a soft and dry cloth to rub the air conditioner or use a vacuum cleaner to clean it f the air conditioner is very dirty use a piece of cloth and soak it with neutral home use detergent to do the cleaning After the season of operation A Set the temperature at 30 C or 86 Fand operate in the fan status for about half a day UAN To make the interior of the units dry 2 Stop the operation of the machine and turn off the power switch The air conditioner will consume about 5W of electric power after the machine is turned off For the purpose Note of energy saving and safety it is advisable to pull the plug out during the non operational seasons 3 Clean and install the air filter screen 5 Take the batteries out from the remote controller If the air filter screen is blocked by dust or dirt the performance of cooling and heating will be affected with the operation n
21. topped for 3 minutes after shut down to protect the unit Please wait for 3 minutes Three minute protection timer incorporated in the microcomputer actuates automatically Except that power is connected this function does not actuate Air is not blown out at starting of heating operation Air blow is stopped to prevent blowing out of cold air until the indoor heat exchanger is warmed 2 to 5 min HOT KEEP The unit will not stop blowing out the air immediately after shut down at COOL operation some model Air is not blown out for 6 to 12 min at heating operation Because the unit is doing mould proofing operation and indoor fan motor runs at low speed The louver will not close down until after 30 seconds When outdoor temperature is low and humidity is high the unit sometimes performs defrosting automatically Please wait During defrosting water or steam are raising from the outdoor unit Air is not blown out at DRY operation Mist is blown out at COOL operation Odor is sent out Indoor fan is sometimes stopped to prevent vapor of dehumidified moisture and save energy This phenomenon sometimes occurs when the temperature and humidity of the room are very high but it will disappear with the lowering of the temperature and humidity Air blown out during operation may smell This is the smell of tobacco or cosmetics sticked to the unit Noise is heard cracking sound 9
Download Pdf Manuals
Related Search
Related Contents
Claudemir Miranda Barboza TSC693E Memory Controller / User`s Manual Technicolor - Thomson DPL680 User's Manual Black Box DEH-P7300R Specifications Juillet 2012 manual media para pdf.cdr Socket 462 System Board User`s Manual LifeWise True HEPA Air Purifier 63-1540 User's Manual Mode d`emploi Joystick CHALLENGER Ji Capitolo 5 Funzioni di programmazione Copyright © All rights reserved.