         Contents
1.  2015  4  TROUBLESHOOTING    4 1  Over counting    If the water flow in the pipeline is uneven and the water is splashing inside the  scanner  try to reduce the water or adjust the water flow  Check and ensure that  the fish not going backwards through the counter again  Check if the fish size is  correctly set on the Control Unit     4 2  Undercounting    Check if the fish size is correctly set on the Control Unit  When too many fish are  pumped through the Scanner Unit  the counter is not able to count all the fish  because the images are overlaying each other  Check the rate of fish  see chapter  2 2 4 minute counting  to ensure the counter is not overloaded  Try to reduce the  amount of fish  and make sure the fish are not blocking up in the pipeline but  gliding smoothly through the pipe  If there is not enough water for the fish to  slide smoothly down the pipe  this can also cause a blockage     4 3  System check    See chapter 2 1 1     5  TECHNICAL SPECIFICATIONS    Control Unit  Single Channel Multi Channel  Dimensions   240 x 160 x 70 mm 300 x 180 x 70 mm  Weight l 2 0 kg 3 kg  Power   12 V DC or 110 220V AC with adaptor    Operating environment     Air temperature  0     40   C  Sea temperature  2     30   C    Page 17 of 18    T vak    Specifications     60000  90000  40000    30000    CONDE  TMS ach HRS    20000    10000       Pipeline Counter Manual   2015       e    Fish hr    a   kgs hr    O  O  O1    E LLL N  wu       gt  0 1  J  44  J  vi    1  N I    0 1 2
2.  3 4 5 6 7    Fish Size Kg    
3. FNC key  will move the flashing cursor between the channels and the number settings  Use the  arrow keys ft  to switch the alarm ON and OFF for each channel and to set the number of  fish which will sound the alarm  Press ENTER after completing all the settings and to return  to the count display screen    When the alarm sounds press RESET key once to turn off the alarm  To reset the alarm you  must re enter the Alarm Settings function and switch the Alarm setting back to ON     DISPLAY  2 3    A  OPTIONS __  Using the FNC key scroll between the 2 display options   Set the TOTAL to ON to show the total sum of all the DISPLAY OPTIONS    channels in the count display screen  The display back  light can also be turned ON or OFF in this function     TOTAL  BACKLIGHT  PERCENTAGE       If percentage is selected  the display will alternate  10 seconds  between the numbers of  counted and the percentage of the total for each channel  6 seconds   The arrow keys ft Y  switch both the functions between ON and OFF  Press ENTER to exit the function menu and  return to the count display screen     Page 13 of 18    N VAKI Pipeline Counter Manual   2015       SI  N  gt  VISION TEST    2 3 5  TEST Ch 1 Ch 2    C m LI       This function is used to check that all the light diodes in the scanner are functioning  properly  With the Scanner disconnected from the pump  and with nothing inside it  all the  squares should be empty  showing that the scanners vision is clear  If  as shown in Ch 1   di
4. HANNEL CONTROL UNIT       When the yellow control unit is turned on  with up to 4 pl x  scanners connected to the 4 inputs  the set size function is Ch 3  displayed on the screen    The size group for each channel can be selected using the Ch 1 Size   arrow keys ff and press ENTER to confirm  1 2 kg _  O   lt 10g   1   10   30g   2   30  150g   3   150   15008   4    gt  1500g    After all the size groups have been confirmed  the results from the last count will be  displayed on the count display screen     2 3 1  Count Display Screen    Chi isthe channel number    152 isthe total count for that channel  H the flashing   symbol indicates the control unit and  scanner are connected        To reset the total count number in the display to zero  press RESET  The following message  will be displayed    PRESS ENTER FOR  Pressing ENTER to confirm that you want to erase all data   RESET    from memory the count numbers will be set to 0  zero         Page 12 of 18         Y VAKI Pipeline Counter Manual   2015       2 3 2  Function Menu    Pressing the FNC key on the Control Unit  you can scroll   ALARM    between the 4 different functions in the main menu  SE  Each function can be selected using the arrow keys PY to OPTIONS  move the flashing cursor to the function you require and Va    pressing ENTER to confirm   EXIT    ALARM  2 3 3   Alarm    Ch1ON__  Ch 2 ON       Ch 3 OFF  Ch 4 OFF  SUM ON       This function is used to set the audible alarm  When in this function  pressing the 
5. Pipeline Counter Wat    User Manual       N VAKI Pipeline Counter Manual   2015       TABLE OF CONTEN Sinai 2  WARRANTY EE 3  LIST COE TEI ua  4  SEL eege 5  L PREG RE ee 6  2  CONTROL UNIT FUNCTIONS aaa ee 7  2 1  SINGLE CHANNEL CONTROL UNIT CONNECTED TO SCANNER       cccececceccccecccceccccececcececeececeecsceecsasecseseceeecseeceaeecs 7  2 2  KONTROLUNIFDISCENNECTED ee ee ne ee rennen 10  23  WUT CHANNEL CONTROL UNIT ee EE 12  e ME 12  Count DISDIGY SCHEN E 12   VAR EEN 13  E a a E EENT UN E REETrEi 13   PAE EE 13  EE EE 13  EEN 14   E EEN 14   3  SET UP AND INSTALLATION ss rien 15  3 1  VACUUM PUMPS EN 15  er SILK SURE AI TEE ERROR  BOOKMARK NOT DEFINED    3 3 COUNTING AND GRADING EE 15  3 4 END OF OPERATION E 16  tel 16   A  TROUBLESHOOTING sn sn nennen 17  AL OVE RO WIN RO Te 17  4 2  UNDERCOUNTING  ccaeneeneneeneeenneennnnnnnnnennnnennnnnnnnnenunnenunnnnunnnnunnnnunnnnsnnnnsnnsnunnnnsnnnnsnnsnsnnsnsnnsnsnnsnsnnsnsnnsnsnnnnene 17  2 3  SYSTEM A 17   5  TECHNICAL SPECIFICATIONS ae 17    VAKI  Akralind 4  201 K  pavogur  Iceland    Tel  354   595 3000  Fax  354   595 3001  e mail  vaki vaki is  www vaki is    Page 2 of 18    y VAKI Pipeline Counter Manual   2015       WARRANTY TERMS    VAKI Aquaculture Systems Ltd  offers warranty for defects that appear within two   2  years from the date of delivery by VAKI Iceland  on condition that the  equipment has been assembled  used  and maintained in accordance with the  instructions for assembly and use     VAKI undertakes to r
6. ellboat when delivering fish for harvesting  or when fish are pumped from one  pen to another under grading or splitting of the cages  The same counter can also be used  at the outlet of a grading machine     The system is based on the use of infrared light beams that form a grid inside the Scanner   Each time a fish is pumped through the Scanner  this grid is broken and an image of the fish  is generated  The image is then used to count the fish     This manual is a guide to the use of the Pipeline Counter     Chapter 2  Describes the functions of the Control Unit    Chapter 3  Contains tips on how to mount the Scanner Unit on different pump types or  grading machines    Chapter 4  Contains Troubleshooting tips and   Chapter 5  Technical Specifications     Page 6 of 18    y VAKI Pipeline Counter Manual   2015       2  CONTROL UNIT FUNCTIONS    The control unit is used to set up the counter according to the fish size and the way the  counter is to be used  In the control unit  there are two menus  one available when the  control unit is connected to the scanner  and the other when disconnected     2 1  SINGLE CHANNEL CONTROL UNIT CONNECTED TO SCANNER  When the yellow control unit is turned on  the results from last count will be displayed on  the screen     4  m 1 D 0 The numbers are      125  examples    In this case  the numbers mean the following     O   lt  10g   1  10   30g   2   30  150g   3   150     15008  4    gt  1500g    4 is the size group selected   ll the flashi
7. epair all defects that are due to faults in the design  materials  used  or manufacture of the equipment  These defects will be rectified by  repairing the equipment  or replacing components  The complete unit or parts  thereof may be required to return to the factory in Iceland for repair     VAKI accepts corresponding warranty for original parts fitted by VAKI as  replacements  for a period of one  1  year from the date supplied     VAKI will not be liable for     Incorrect assembly and use  or inadequate maintenance    Defects which result from the fitting of materials  components  or  devices not supplied by VAKI  and which are purchased and fitted by  the user    Defects due to changes made to the equipment by the user  without  the written consent of VAKI    Faulty or inadequate repairs carried out by the user     Normal wear and tear of the equipment   Faulty connection of electrical equipment   Faults caused by excessive voltage   Damage or stoppage due to immersion of the computer or camera in  water   Damage to electrical supply cables     Any economic loss that may arise from production stoppage        If faults or defects appear in the equipment  the user must report this in writing  to VAKI or its appointed representative as soon as possible  and without  unjustifiable delay  The report must be sent within two  2  weeks from the expiry  of the deadline  which is two  2  year from the date of supply by VAKI Iceland     If the purchaser does not inform VAKI or its 
8. l blink in the lower left corner  the value shown here  as    x  is meaningless  If all the squares are empty  the scanners vision is clear  The bottom row in  the display indicates the light rays going from top to bottom of the scanner transmitted by  the diodes in the bottom and top of the scanner     EICO0O O 00000    If  as shown  diodes are blocked and the windows are clean with nothing inside the scanner  there may be a problem with the scanner  Please contact VAKI or your local distributor     Page 8 of 18       vai    Pipeline Counter Manual   2015       2 1 2 PRESS ENTER TO   See SET SIZE  To set size group  press FN and the down arrow  4   twice and the display shows     PRESS ENTER FOR     SET SIZE       SET SIZE  30   1508    Use the arrows to choose the right size group and press ENTER     2 1 3 PRESS ENTER TO        One minute counts  This function is to enable disable the display of the number of fish counted during the last  minute  60 seconds   The number is updated every 7 5 seconds and is useful to check if the    counter is being overloaded and make adjustments to the pumping rate or flow of fish   Press FN  then Y three times and ENTER  The display will show     1 minute counts  NO    Use the arrows to select YES or NO and press ENTER    Page 9 of 18    N VAKI Pipeline Counter Manual   2015       2 2  CONTROL UNIT DISCONNECTED    When the Control Unit is turned on when disconnected from the scanner  the connect  frame message will be displayed  and the ba
9. line or the outlet of a grading  machine  Dewatering is generally not necessary  We recommend that the scanner unit be  mounted at the end of the pipeline  and with a slope of between 20 402     Page 15 of 18    N VAKI Pipeline Counter Manual   2015       3 4  End of operation    When all fish have been counted     e Turn the Control Unit off by pressing the ON OFF key    e Disconnect the cable from the Control Unit and the Scanner Unit    e Screw the protective caps onto the connectors on the Scanner Unit   Control Unit  and the cable  and put the Control Unit away in a safe place   It is very important to replace the protective cap on the cable connector of  the Scanner Unit if it is left outside  otherwise the contacts will soon be  damaged by corrosion  If the scanner is to be used again soon  it can be  left on the pump  but over a longer period  we recommend that the  Scanner Unit is stored in a dry place     3 5  Storage    e Store the equipment in a safe  dry place when not in use     e Keep the protective connector cap on the Scanner Unit  Control Unit and  at the ends of the cable     e Clean the windows  inside the Scanner Unit  with a soft cloth and some  detergent  Dirt and debris can absorb part of the infrared beam  It is  necessary to keep the windows and if they are very dirty  you can clean  them with ethanol or some disinfectant     NEVER CLEAN THE WINDOWS WITH ACETONE  AS IT WILL RUIN THEM COMPLETELY        Page 16 of 18    N VAKI Pipeline Counter Manual  
10. ng   symbol indicates that there is contact between the control unit  and the scanner  and the amount of charge left in the battery    150  in large digits  is the total count   125  small digits in the lower line  are the number of fish counted in the last 60  seconds  See chapter 2 1 4    To reset the total count number in the display to zero  press RESET  The following message  will be displayed     PRESS ENTER TO  To reset all data from the  E  CONFIRM RESET Control Unit    Pressing ENTER to confirm that you want to erase all data from memory the total count    number will be set to 0  zero      Page 7 of 18    N VAKI Pipeline Counter Manual   2015       Pressing FN on the Control Unit  you can scroll between the 4 different functions in the  menu using the arrow keys  The menu is as follows     PRESS ENTER TO  To check that all infra red light  CHECK SYSTEM diodes are functioning properly    U  PRESS ENTER TO  To choose the size of fish that  SET SIZE are being pumped   TU    PRESS ENTER TO  To display the number of fish  One minute counts counted during the last minute     PRESS ENTER TO   SYSTEM CHECK  This function is used to check that all the light diodes in the scanner are functioning    properly  With the Scanner disconnected from the pump  and with nothing inside it  press  FN  The following will be displayed     PRESS ENTER TO   CHECK SYSTEM    Press ENTER and the following will be displayed        DRSSRRRRRRRIRIRRRE    ll        The battery status indicator wil
11. odes are blocked and the windows are clean with nothing inside the scanner there may  be a problem with the scanner  Please contact Vaki or your local distributor  Press ENTER  to exit this function and return to the count display screen     Press ENTER to exit the function menu and return to the count display screen     Page 14 of 18        VAKI Pipeline Counter Manual   2015       3  SET UP AND INSTALLATION    The scanner must always be mounted so that the connector is on the side     connector    3 1  Counting from a pump    The counter should preferably be mounted at the end of  the pipe transporting the fish into a tank or a cage    If this is not possible  then it is important that the  counter is vented to the atmosphere  otherwise the the  counter will form a    resting pool    where the water  velocity is lower than in the pipes connected to it and  fish may crowd in the counter opening  making accurate  counting impossible  This venting can be accomplished  by making 30     40 mm holes in the top of the plastic flanges  It is necessary that the pipe  downstream from the counter is downward sloping all the way        Usually  it is not necessary to dewater the fish when using a centrifugal pump  except for  the smallest sizes  When using a vacuum pump  dewatering may be necessary because the  water output from a vacuum pump may be saturated with air bubbles and non   transparent     3 2  Counting and grading    The Pipeline Counter can be mounted on the end of a pipe
12. representative within the time limits  stated above  the purchaser shall forfeit the rights of the warranty     Page 3 of 18    Waki    LIST OF ITEMS    The main parts of the Pipeline counter are     1     2     3     4     5     Plastic Scanner Unit     Control unit   single  channel or multi      channel     Flanges for mounting the  counter to a pump or  pipeline     Fittings    Pipeline Counter Manual       2015          Page 4 of 18       Pipeline Counter Manual   2015       SET UP       1 Channel 4 Channel An industial PC can be used  Display unit  DU  Display unit  DU  to connect upto fourPLC  EEE ene SO BE e Ee ET scanners    lt  gt     or           AC adaptor    PowerCable  for 12v Battery  with fuse  2m     Standard 12v  car Battery       PLC Main Cable  20m     Flanges   All sizes from 4    14      Various designs of hose pipe  connection available     Page 5 of 18    N VAKI Pipeline Counter Manual   2015       1  PREFACE    VAKI Aquaculture Systems Ltd thanks you for choosing the Pipeline Counter  PLC   More  and more aquaculture enterprises are using equipment from VAKI in their day to day  production and management  An accurate knowledge of the number of fish  and the  average weight and size distribution in each pen is the basis for success in today   s tough  competition     The Pipeline Counter  PLC  from VAKI has been developed in close collaboration with our  customers  It is currently being used for counting fish when being pumped either from a  pen to a w
13. ttery symbol will not flash     STT FRAME    Pressing FN on the Control Unit  you can scroll between the 2 functions in the menu using  the arrow keys  The menu is as follows     PRESS ENTER TO  To see which program version is  PROG  VERS  in the Display Unit  Button Test    Ty    PRESS ENTER TO  To choose between English   SET LANGUAGE Norwegian and Spanish    Page 10 of 18    Y VAKI Pipeline Counter Manual   2015       2 2 d PRESS ENTER TO    er PROG  VERS   This function is used to see which program version is running in the Control Unit  To check  the program version press FN  The following will be displayed on the screen     PRESS ENTER TO   PROG  VERS   Press ENTER and the following is displayed     PRESSENTER 11 2  A 1 13 B 0 7    The number in the top right is the voltage being received by the control unit and the  program version shown in the bottom line    There is also a button test function  the letter    P    in PRESS on the display will change  according to which buttons are pressed     To get out of this function you must turn off the Control Unit     2 2 2 PRESS ENTER TO    dd SET LANGUAGE  You can choose between English  Norwegian  and Spanish  Press FN  then Y once and  ENTER  The following will be displayed     PRESS ENTER TO   SET LANGUAGE    Press ENTER and the following will be displayed     TRYKK ENTER FOR  NORSK    Use the arrows to choose language  and press ENTER to confirm     Page 11 of 18    N VAKI Pipeline Counter Manual   2015       2 3  MULTI C
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Manuale d`uso - dB TECHNOLOGIES  Manual - Heat-Rite VST - Val-Co  Arrow VT1431 Instructions / Assembly  Installation Manual JY992D93901-E  6700-0072-000 CVR service manual RevD.qxp  USER`S MANUAL - Icon Heath & Fitness  陸 上 自 衛 隊 仕 様 書  exemplar de assinante da imprensa nacional  Instrukcja obsługi  Samsung ATIV Tab 7 XE700T1C-K01PL User Manual (Windows 8)    Copyright © All rights reserved. 