Home

Assist User Guide New Front V3 - Nikon

image

Contents

1. Nikon Assist Online EDI Support 01908 214100 Option 5 Supplier 7 Account Job Type Nikon UK NewRx Stock zd 0001947 0001947 7 Uncut Frame Option _ Frame Option Supplier Account Job Type Nikon UK NewRx Rx bd 0001947 0001947 bd Edged kd R edged Nikon Online lens Please enter prescrip tion as SV lens in the patient tab As per image to the right the Degression Lens Index and Coating can be chosen via the Patient Lens Measurements Calc amp Finishing E Right Eye LeftEye Lens Type Click Once To Remove Sy SV Ta Lens Design Nikon OnLine Lens Design Nikon OnLine aa Material FP3 1 67 SeeCoat 2 000 deg A FP2 1 67 SeeCoat 1 500 deg FP1 1 67 SeeCoat 1 000 deg FP1 1 67 HCC Ikon 1 000 deg FP2 1 67 HCC IKON 1 500 deg FP3 1 67 HCC IKON 2 000 FP1 1 67 HCC Ikon 1 000 deg FP1 1 67 HCC 1 000 deg FP2 1 67 HCC 1 50D deg FP3 1 67 HCC 2 000 deg EP2 1 6 SeeCoat 1 50D deg lens material option Te Supplier Specify the source of lenses to fulfil your patients ee prescription e Account Your account number will be displayed here PEE Job Type Frame Options If Uncut was chosen as Job Type then only Lens Only will be shown as Frame Option apieve N If Edged then you can choose between R Edged Remote Edging or Frame to Follow on the Frame Options Height and PDs for Online lens will need to be Near Heights and Ne
2. Sphere Cylinder Axis Addition Prism1 Base 1 Prism 2 Base 2 fens me 01 00 oon plsazo0 out RE 0150 o200 J11 ka Ea Ea Le 0200 __ o175 20 poo ue JIO TS Remove Prism 1 5 T6 Grey HCC Ikon zs Treatments Select X Tints Select jd Home Consumer Professional SEE Series Nearest store Assist On Line Ordering e Standard Edge Comparison e Online Lenses e Variable Inset Welcome Brenda aa Once you have logged in click on Order now and New RX Lens to start your order Reference Practice reference for order Sphere Enter the sphere power in 0 25 steps This will default to a plus unless the power is prefixed with a minus Cylinder Enter the cylinder power in 0 25 steps This will default to a plus unless the power is prefixed with a minus Axis Enter the value in a range of 1 to 180 degrees Addition Enter the addition in quarter dioptres Prism Enter the value in Prism dioptres Base Indicate the direction of the prism by typing in out up or down Availability of Lens Design is based on prescription entered in Step 4 Lens Type Three Options SV Single Vision Bifocal and Progressive SV only available based on prescription entered Lens Design Select the required lens design Lens Material Select the required lens material Nikon lehis ar click NEXT to con
3. ar PDs Measurement tab Patient Lens Measurements Il Calc amp Finishing E e Standard Edge Comparison e Online Lenses e Variable Inset Customer Note Please be advised that we will from the 15t of April 2010 remove access to our ordering system and replace with a new improved version called New Rx If you need more information or would like to book in an appointment for training please contact your area sales manager or the MIS team on 01908 214 100 Option 5 SeeMax Power 13 Lens Design ____ Lens Material 1 67 T6 Grey HCC Soifo is i Lens Material p 167 T6GreyHcce HW click instructions for details TALTES heinean u Select i zdl Tints ried Select you must tick this box to confirm that you have read the Legal Notice below containing the Terms Secure login Name nouktest ssword eeeeee Submit Prism Thinning HV Inset RE Select oso e LE Select koso Enter your Username and Password and click submit Prism Thinning Select standard or without NV Inset Near Vision inset range between 0 0 and 5 0mm See variable inset PDF Patient Lens lL Measurements l Cale amp Finishing E Riant eve Letteve Patient Lens Measurements Calc amp Finishing Import Data Reference Nikon Order Lens Type Click Once To Remove BiFocal wd Lens Design Bifocal Lens Design Lens Material 1 5 T6 Grey HCC Ikon Bifocal 9 Lens Material
4. ight Optimum Thickness Type 32 18 v Edge Th fl 15 Oe i Edge Thickness d 5 Import a Trace F0135661 1S0 RE ABox RE BBox Calc DBL LE ABox LEBBox 5250 2904__ 178 5249 ___ 29 05 Remote Edge Order Lab Trace Select the frame type brand model and size Enter PDs and Height measurements as required Upload Trace Click on browse and select trace to upload Enter PDs and Heights as required click NEXT to continue k Patient I Lens Measurements Il Calc amp Finishing Lens Design Optimum Thickness Type _ RE m Esge Thickness fidf1 te Ee manes is jis Front amp Cut View Lens Design Click the Calculation button to view the front and cut view Click zoom in to enlarge the image Diameter Lens Base Cntr Thickness Weight Patient Lens Measurements Calc amp Finishing Lens Design Finishing Edge Type Groove Frame Type Supra Edge Polish f Edge Finish Chamfer Groove Front _ Back lt Depth los RE Auto i 47 l None pe None 4 Width 0 5 Front Back pcb Ss LE Auto H Ld None 4 None aa Gy A Front amp Cut View Calculation GO A PD Go Qa To select Edge Polish click on Tick box in Finishing Tab which can be found in Calc amp Finishing tab Please note all Nikon products may not be calculated online at this stage Nikon Assist Online EDI Support 01908 214100 Op
5. tinue Coating Select the coating required Tints are in absorption click NEXT to continue _ Patient Lens Measurements Cale amp Finishing Frame Data Entry Type Frame Type Pick A Shape ha Select o Pp Height Optimum Thickness Type h _ Min re s2 s m Esge Thickness ilfo _ 00 G Eal z LE Edge Thickness Talo 0 0 ABox BBox DBL M a OM 00 OO AM seee w Uncut Lens Order Pick a shape Select a frame type Enter measurements into PD Height and Thickness type Select a standard shape by clicking on the image at the bottom Provide the frame measurements ABox BBox and DBL Frame Data Entry Type Pick A Diameter 4 Diameter Reduced Diameter Thickness Type RE 75 isd mm Imm Lab Decides _ Eg Ea LE 75 sl mm mm Lab Decides bed Pick a diameter Select diameter required for the order An optional reduced diameter can be entered To remove Optimum un check the box Patient l Lens I Measurements Calc amp Finishing Frame Data Entry Type Frame Type d Select PD Height Optimum Thickness Type Min re 32 ls m Esge Thickness ifo 0 0 oo eel JLE 32 _ J18 Edge Thickness bi 0 Brand Me SO Betect lid Select ft Select hd LINDBERG SILHOUETTE STEPPER Patient _ Lens I Measurements Calc amp Finishing Frame Data Entry Type Frame Type Upload Tr ace ed Metal Frame pp He
6. tion 5 Once you have entered your order you can Send Now Transmit the order to Nikon Preview Display in a pop up window Save Order Should you wish to send the order later on you can click on Save Order order will appear in your Pending section New Order Cancel the current order and start a new one Tracking your Order Pending Order All saved orders are stored here Order Status To check current status of all orders placed Archives stock should you wish to archive old orders they can be stored here Summary Errors Supplier Nikon UK NewRx Stock Account 0001947 0001947 Job Type Uncut Frame R edged Rx Information Reference Nikon Order Sph Cyl Axis Add RE 01 50 02 00 111 LE 02 00 01 75 20 ID PO Lens Information RE Nikon Lite AS Organic 1 50 HCC IKON LE Nikon Lite AS Organic 1 50 HCC IKON Measurement information PD Height RE 32 11 9 LE 32 12 ABox R BBox R DBL ABox L BBox L 48 17 23 75 1872 48 31 23 95 Frame Information Frame Type Metal Frame The Summary section above shows the order details You can click on the tabs at the top at any time to change them The errors section will display any errors which occur during the order entry process

Download Pdf Manuals

image

Related Search

Related Contents

Texto integral - Repositório Aberto da Universidade do Porto  5 - American Standard  ET2870PP - Cobertes  Jet IO 6550 Manual v1.6    Gigaset A120-A120A_A220  Rexel 546206 folder  Gebrauchsanweisung Operating Instructions Notice dÛutilisation  SERVICE MANUAL DISHWASHERS - M  Un singe anagramnésique / Richard Deschènes, Systèmes  

Copyright © All rights reserved.
Failed to retrieve file