Installation and Operating Instructions
Contents
1. 16 Sealing brush 17 Connector clamp 18 Connector 19 Screws for bottom guide rollers 20 Screws with washers and nuts for fixing brackets 21 Split pin for connector 22 Bag of screws for connector 23 Cover buttons Number depends on the door size Fixation material for the foundation is not included in the delivery scope Optional scope of delivery 24 Emergency release device 6 Installation and operating instructions VEIRTICO These instructions are intended for a standard location with sufficient room at the lintel www samsondoors co uk Que ZAZA 2 In the special case of mounting on the ceiling please contact the manufacturer Assembly Lintel standard situation Ceiling VEIRTICO Assembly measurements Room requirement for the wall side at Clearance width the top 3485 mm 2400 mm 4120 mm 2401 3000 mm 5410 mm 3001 4320 mm 6750 mm 4321 5620 mm Stop for corner deflection unit min 130 Element width Clearance width Room requirement at the top on the wall side Room requirement at the bottom on the wall side Element height Clearance height Instal
2. 6 14 Installation and operating instructions Installation WWW Samsondoors co uk OILS Ss 2 AL EOS Move the upper track B approx 600 mm from the corner deflection unit C Pull the brush inlay D up to the corner deflection unit C If the depth of the room does not allow you to pull the brush inlay the upper track B can also be detached Place an edge protector E e g a piece of carpet in the corner over the bottom corner deflection unit Place the assembly aid F in the bottom corner of the door e Insert the curtain G as follows Insert the side with the door closing profile H first Insert all the way along the runway of the upper track B Remove the assembly aid F and the edge protection E Screw the connector clamp L to the connector K Slide the connector K into the slot of the connection profile M from below Insert the split pin N through the drill hole of the connection profile M and the connector K Force the split pin N apart on the other side VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EO 6 Installation Slide the brush inlay D back into the upper track B Slide the upper track B past the connector and up to the corner deflection unit C Position the upper track B on the markings e Tighten the screws on the fixing brackets A Advice The sealin
3. Caution To avoid personal injury or damage to property the following points must be observed Target group The installation instructions are intended for qualified and trained specialist persons Mounting initial operation setting works and service to the door and motor unit may only be carried out by qualified and trained specialist personnel Qualified and trained personnel in relation to these installation and operating instructions are persons who have been adequately trained by or are supervised by electricians and technicians and are therefore capable of recognising hazards which can arise when dealing with electricity and mechanical forces They need to have the following qualifications corresponding to the respective work to be carried out in particular knowledge of the general and special safety and hazard prevention regulations knowledge of the relevant electro technical regulations training in the use and maintenance of adequate safety equipment The following guidelines must be observed this list is not exhaustive VDE engineering guidelines VDE Association of German Electrical Engineers VDE 0113 electric equipment with electronic components EN 60335 1 Household and similar electrical appliances Safety Fire prevention regulations Accident prevention regulations VBG4 electric equipment and operating means ZH 1 494 Guidelines for electric windows doors and gates 13241 1 Product standar
4. 0 e 0 PN OOF On E Oe Ke e e e e e Meny 1 Automatic closing timer E im A1 B1 ci D1 E1 FI Gi H E T E T 7 O O Menu 3 Door open duration in seconds e e O d K 2 5 10 15 20 25 30 35 40 50 80 100 120 150 180 255 O 5 O Menu 4 Warning time in seconds e e O n O 1 2 5 10 15 20 25 30 35 40 45 50 55 60 65 70 OS Menu 5 Start up warning in seconds e e of so EB 1 2 3 4 5 6 7 E E 7 O Menu7 Signal light e e 50 A7 B7 C7 D7 E7 F7 O60 e LED on jet LED pulses Factory default setting O LED off 39 LED flashes quickly E d LED flashes quickly Not possible 40 Installation and operating instructions VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 11 Extended operator functions f Advice wd The automatic closing timer can only be programmed if a photocell or a closing edge safety device is installed The functions in Menu 1 can be altered as desired via the time settings in Menus 3 and 4 Menu 1 Automatic closing timer Setting D Pas SPED Warning time Automatic closing timer Other functions uration A1 deactivated E B1 15 5 activated C1 30 5 Ber areal Renewal restart of the door open duration after the photocell barrier has been driven past D1 60 8 activated E1 15 5 activated F1 30 5 Beaver ae Interruption of the door open duration after the photocell barrier has been driven past G1 60 8 activated H1 EA 3 EE Closes after the photocell barrier has bee
5. 16 Installation and operating instructions VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 6 Installation Align the closing edge rail A flush with the upper track B Secure the position with a screw clamp Drill through the closing edge rail A into the wall Screw the closing edge rail A to the wall Cover the drill holes in the closing edge rail A with the cover buttons C Remove the screw clamps e Advice Quick release operation is described in section 7 Release the door Move the door slowly into the OPEN and CLOSED positions w Check The door must move easily into the OPEN and CLOSED positions 6 6 Fitting the covers Place the upper plug cover A in the upper roller rail B over the door opening VEIRTICO Installation and operating instructions 17 WWW Samsondoors co uk OILS Ss 2 AL EOS 6 Installation Slide the bottom end cover C into the floor track D on the wall side Place the second end cover C in the floor track D on the door opening side Fit the cover E in the upper track B on the door opening side 6 7 Assembling the emergency release device optional Attention To avoid damage to the door and lock the key may not be inserted in the emergency release lock while the door is moving Place the cover A on the door leaf from the outside
6. Guide the bowden cable B from the outside through the cover A and the door leaf Screw the lock counterpart C to the lock D from the inside The slotted side of the lock counterpart C must face the motor unit 18 Installation and operating instructions VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 6 Installation e Screw the bowden cable cover E to the connector F Lay the bowden cable cover G at the door Attach the bowden cable cover G at the connector F with the screw of the bowden cable retainer E Pinch off the bowden cable cover G 50 mm before the lock counterpart C e Loosen the preassembled bowden cable bracket I Screw the bowden cable cover G with the bowden cable bracket I securely to the carriage H Guide the bowden cable B from the lock through the bowden cable cover G into the carriage H Pull the lock 30 40 mm out of the lock cover A Attention To avoid damaging the carriage H the clamp J must be held using an open ended spanner wrench size 8 when screwing Guide the bowden cable B through the clamp J and tighten the bowden cable B Pinch off the bowden cable 30 mm behind the clamp J Secure the lock D VEIRTICO Installation and operating instructions 19 WWW Samsondoors co uk OILS Ss 2 AL EOS 7 Quick release and emergency release Attention To avoid damage to the door the door may on
7. Apply a load of 20 kg to the middle of the lower edge of the door whilst the door is running The door must stop immediately Automatic cut out CLOSING Place a 50 mm high obstacle on the ground Drive the door towards the obstacle The drive system must stop and reverse when it comes into contact with the obstacle f Advice ud The parameter settings are still saved if the power supply is disconnected Only a reset causes the driving power settings for the OPEN and CLOSE directions to revert to the factory settings e LED on jet LED pulses Factory default setting O LED off LED flashes quickly E d LED flashes quickly Not possible 32 Installation and operating instructions VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 11 Extended operator functions 11 1 General notes on extended operator functions Additional functions can be programmed for the operator system using the extended functions Caution Important factory default settings can be changed using the extended functions All the parameters must be set correctly to avoid damage to persons or property The programming facility is divided into three areas Area 1 Levels The adjustable functions have been grouped in 8 levels according to the type of function Each level can have up to 8 menus The and buttons are used to scroll through the selections within the levels Levels that are not used are displayed but cannot be opened Levels Exit sw
8. driver ON Press the desired button on the hand transmitter A new code is then generated by the integrated random coding facility The LED flashes quickly As soon as the LED lights up permanently the hand transmitter has been programmed with a new code The button can then be released and the transmission plug removed Advice After the hand transmitter has been re programmed the operator system must also be re programmed to respond to the new code For multi channel transmitters the programming process must be carried out for each button separately VEIRTICO Installation and operating instructions 25 WWW Samsondoors co uk OILS Ss 2 AL EOS 10 Initial operation 10 1 Connecting the operator system Connect the motor unit to the electricity supply All control lights will be lit up for approx 3 seconds 10 2 Overview of the control unit Operating elements O Label Type function gt A Carousel display 10 3 OPEN button B e g to drive the door to i the OPEN position or to increase parameters when programming CLOSE button e g to drive the door to the CLOSED position or to decrease i parameters when programming Button p D e g to switch to i programming mode or to save parameters e LED on jet LED pulses Factory default setting O LED off LED flashes quickly E d LED flashes quickly Not possible 26 Installation and operating instructions VEIRTICO
9. e 1 r Door CLOSED o 54 O O e Start advanced O o programming 812 2 p Programme 9 6 4 O intermediate position In Level 1 Change to gua UE E Menu 3 e S O E 4 Change to 812 programming mode E a 4 Set the 5 intermediate position i es with 4 and 9t Save intermediate Bla E E position e T 7 End programming O 8 Drive the door to 1 a the CLOSED position oe O O o Advice After changing the intermediate position a learning run must be carried out again The learning run is described in section 10 7 30 Installation and operating instructions Uk QE ors A de Important factory default settings can be changed using the extended functions All the parameters must be set correctly to avoid damage to persons or property Remote control intermediate position 10 Operation mode Door CLOSED Start advanced programming Programme remote control intermediate position Select Level 4 In Level 4 change to Menu 1 In Level 4 change to Menu 2 Change to programming mode Activate hand held transmitter Release hand held transmitter Save remote control intermediate position End programming VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 10 Initial operation 10 7 Function test Learning run for determining the driving power Check After express programming and after making changes to the programming menu the
10. following learning runs and checks must be carried out The operator system determines the maximum required driving power during the first two runs after setting the end positions of the door Operate the operator system with the door coupled to drive the door once from the CLOSED position to the OPEN position and back to the CLOSED position without interruption During this learning run the operator system determines the maximum push and pull forces and the reserve power required to move the door Test 1 After pressing the button The door must open and travel to the saved OPEN end position 2 After pressing the button The door must close and travel to the saved CLOSED end position 3 After pressing the hand transmitter button The operator system must move the door in either the OPEN or CLOSE direction 4 After pressing the hand transmitter button while the operator system is running The operator system must stop 5 When the button is pressed again the operator system moves in the opposite direction VEIRTICO Installation and operating instructions 31 WWW Samsondoors co uk OLOSS 29472 16 10 Initial operation Checking the automatic cut out Caution The automatic cut out must be correctly programmed for the CLOSE and OPEN directions to prevent damage to persons or property Automatic cut out OPENING For drive systems where the door has openings in the door wing diameter of opening gt 50 mm
11. is possible to transfer the coding of a hand transmitter that has already been programmed for operating the operator system master transmitter to another hand transmitter Caution Before operating the hand transmitter ensure that there are neither persons nor objects in the operating range of the door Connect both transmitters with the enclosed transmission plug Actuate the master transmitter and hold the button The transmitter LED lights up e Whilst keeping the button on the master transmitter depressed press the desired button on the other hand transmitter The LED flashes After 1 2 seconds the LED on the newly programmed transmitter lights up permanently The programming procedure is complete The coding of the master transmitter has now been transferred to the other hand transmitter Remove the transmission plug Advice For multi channel hand transmitters the coding procedure has to be carried out for each button separately 24 Installation and operating instructions VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 9 Hand transmitter Change coding If a hand transmitter has been lost this function can be used to change the coding of the remaining remote control transmitters Connect one end of the transmission plug to the hand transmitter At the free end of the transmission plug short circuit one of the outer pins with the centre pin adjacent to it e g using a screw
12. operator functions Installation and operating instructions 39 WWW Samsondoors co uk OILS Ss 2 AL EOS 11 Extended operator functions Level 2 Operator settings 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 O A e olose ofo 08 s o9e Te of o e Of o9e of o e of of x e e e 9 o S 20O e ec 20 Or 20 e KE 3 Or Or e e 2 e e 2 O7 2e Or 2e A 2 e 2 e 2 e e O eo 260 C40 06490 060 O60 O6 o O49 Ogee Hee ee ee ee ego e Menu 1 Required driving power OPEN sensitivity in increments o o Or o 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 O60 Menu 2 Required driving power CLOSE sensitivity in increments oOx e 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 eo Menu 3 Automatic cut out OPEN sensitivity in increments e e LES X OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 od Menu4 Automatic cut out CLOSE sensitivity in increments e e Or 50 OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 o The higher the setting the higher the driving power The lower the setting the more sensitive the automatic cut out Caution To exclude any risk of injury the automatic cut out Menus 3 and 4 may only be switched to OFF if a photocell barrier or closing edge safety device is installed Level 3 Automatic closing timer 6 7 8 9 10 11 12 13 14 15 16 O Ors Ww Mi Othe oo oo ox oe oe o9e cof o9e of o9e o9e o9 e coffe coffe Fe e e O 1 1 59 On 2e O7 3 On 29 ole On 5 07 30 e 07 0 e e o gt o 5 5 O E e Ow e e 0 e 0 ele e
13. LED on jet LED pulses Factory default setting O LED off LED flashes quickly E d LED flashes quickly Not possible 48 Installation and operating instructions VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 12 Messages 12 3 2 Malfunctions with error messages Error Cause Solution Message 7 OY lfno buttons are pressed within 120 seconds the programming mode terminates automatically O OPEN and CLOSED door positions programmed without passing the reference point O o9 Message 8 Jef O O Reference point button defective Have the operator system checked o O o9 Message 9 ut O No speed sensor impulses Have the operator system checked Orz 5o drive system is blocked O e Message 10 Jef O z Door movement too Stiff Ensure that the door moves easily Or 50 Door blocked O o9 Maximum driving power setting is too Have the max driving power Section 11 4 Level 2 low Menu 1 2 checked by an expert Message 11 tO O n Excess travel stop Have the operator system checked O 7 3 Te O o9 Message 15 Jef O External photocell interrupted or Remove obstacle or have the photocell checked jit o defective O e Programmed for photocell but no Deactivate or connect the photocell photocell is connected Message 16 o9 Power sensor for the automatic Have the motor unit checked jt te cue esie Wes O50 Message 26 iC Undervoltage operator system Have the external power
14. Not possible VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 17 Extended operator functions 11 4 Functions overview for the levels Level 1 Basic functions 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 e m An 5 oo ee of 0o96 ofe o9 e o9 e o9 e oe o9 e o9 e o9 e o9 e o9 e x9 e e e 9 e On e e e On ome e er Oe S e e e Ti w O e 0 e 0 e 2 9 O O62 OO 969 0649 Ooo C640 o obe O49 Oe Hee e 0 e 0 e 0 0 40 099 Menu 3 Intermediate position OPEN ES ce Set using the OPEN and CLOSE buttons 7 2 7 T P HE evt Intermediate position OPEN closing function is possible with automatic closing timer Menu4 Intermediate position CLOSE CR l Oz 30 Set using the OPEN and CLOSE buttons O A X Q A MenuZ7 Relay output only programmable with optimum signal light relay 2 X50 AZ B7 C7 D7 E7 F7 G7 H7 17 J7 K7 E 2 O60 Menu 8 RESET eo O Or s0 F No Yes 2 T E O60 Attention To ensure trouble free programming the door must be in the CLOSED position before resetting f Advice ud After a reset all the parameters revert to the factory settings In order to ensure that the controls operate properly all the required functions must be re programmed the remote control unit must be re programmed the drive system must be driven once to the OPEN and CLOSED door positions Only the intermediate position that was programmed last can be used If an auto
15. SED end position The carriage must be connected up The controls are programmed using the plus minus and P buttons If no buttons are pressed within 120 seconds while in programming mode the controls revert to operating mode A corresponding message is displayed Reference p i The messages are explained in Section 12 e LED on Os LED pulses Factory default setting O LED off Be LED flashes quickly E d LED flashes quickly Not possible 28 Installation and operating instructions VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 10 Initial operation Carry out the express programming according to the following procedure O Start express programming Programme the door OPEN end position GT A 1 O b bi O Oc Operating mode Drive the door to the OPEN position Correct the OPEN door position using and Save the OPEN door position Programme the CLOSED door position Drive the door to the CLOSED position Correct the CLOSED door position using and Save the CLOSED door position Programme the remote control Press the hand transmitter button Release the hand transmitter button Save the remote control settings End the express programming procedure VEIRTICO Installation and operating instructions 29 www samsondoors co 10 Initial operation 10 6 Advanced functions Caution Intermediate position O 1 Operating mode
16. WWW Samsondoors co uk OILS Ss 2 AL EOS 10 Initial operation 10 3 Overview of the display functions LED displays in operating mode D Photocell beam interrupted Door in CLOSED position INC Door moving towards OPEN position Reference point is switched rd S Doorin OPEN DOON Permanent actuation of an external control P element ox Door is at intermediate position Remote control is actuated 40 IN I Door moving towards CLOSED position Operating voltage I 10 4 Reference point e In operating mode LED 5 lights up briefly when an object person passes the reference point Advice wl In the factory default setting and after a reset the controls are set to start in the CLOSED door position To ensure trouble free programming therefore the door and the operator system must be in the CLOSED end position before resetting or carrying out the express programming procedure VEIRTICO Installation and operating instructions 27 WWW Samsondoors co uk OLOSS 29472 16 10 Initial operation 10 5 Express programming f Advice ud For proper initial operation of the operator system the express programming procedure must be carried out This applies for the initial operation and after resetting When programming the OPEN and CLOSED door positions the reference point must be passed Preconditions The following conditions must be assured before express programming can commence The door must be in the CLO
17. WWW Samsondoors co uk OMS Sy 2 TIDAL We VEIRTICO WOM Last updated 08 2008 Installation and Operating Instructions Comfort Overhead Garage Door System made of Aluminium ALULUX Experience the best quality 1 WWW Samsondoors co uk OILS Ss 2 AL EOS Contents au B WN 10 11 12 13 CODLBHIS 91029233 9929 9999 09 999 95 0 94 4 9912 3192919 9191 923599 39 20099 9 eee eee Meaning OF symbolS 4494 9130093 398 89 90093 0909 80808 9 9 60 ae e ea ed Faber Ew R E hd General safety advice wostesossEQPCEEPCPRPTIESECHERRERPEPAT E C MBCESTEPR BODIE RE SE 2 3 3 SCONE OF SUDDIV reroror siers EE CRRY PRU S NEEE SPI DEUS FUR SE ER pads edes Assembly measurements eeeeeeeeeeeeenee eoo o o oss o n s 7 8 Installation e eo 0o 0 E 09 O0 O9 O O0 O0 O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O 6 1 Checking the installation conditions seeeeeeeeeeeeee HH hee 8 62 Mound The UDBOI TACK ov cora veuvERRERERRE RASA USUS RUCEN ETE DRMIMME STEP EX REUMU CNET DURER RENS 10 6 3 Assembling the floor rails viscid ccsciceascsidaetacssca eeiadeeas as ei RR EY Ga Rada dev ead ys 11 64 Installing ENS Curtain eec oscba d awo uuu ones x RP adedaskta ui ededadenauisdfastersd dies pitepqp ed 13 65 Mounting the closing edge rail 2css cus cR REERRARRERRERECRRE E RA EN ERPR3WRRer
18. ables are laid separately from control cables The controls voltage must be 24 V DC If external voltages are applied at terminals XP020 XB10 or XBO1 the entire electronic system will be destroyed Only potential free normally open contacts may be connected to terminals 1 and 2 XB01 The shorting plug should never be plugged into the XP020 system socket Q Reference gt When installing external control elements or safety and signal equipment the relevant instructions must be observed e Label Type function gt Connection of external control XBO1 elements without system cabling and a two wire photocell XB10 Connection of external control Fig elements with system cabling 8 3 8 4 XP020 Connection of system photocell or 11 4 adapter cable for modular antenna Level 8 XB70 Connection of modular antenna E f Advice atl Before connecting a control element to the terminals with system sockets the corresponding shorting plug must first be removed VEIRTICO Installation and operating instructions 21 WWW Samsondoors co uk OILS Ss 2 AL EOS 8 Connection of control elements Terminal XB01 Fig 8 2 Label Type function 1 GND 0 V 2 Impulse 3 24 V DC max 50 mA 70 GND 70 71 Two wire photocell RX Receiver for the two wire photocell Sb External impulse button if applicable TX Transmitter for the two wire photocell Advice Ifa photocell is to be connected it must be installed before the e
19. ck on the OPEN and CLOSE automatic shutoff setting once a month Check all movable parts of the door and motor unit e Check the door system for deterioration or damage Manually check the movement of the door Measures to protect against corrosion Allow for sufficient water drainage on the outside so that the door parts are not in constant contact with water Allow for sufficient drying and aeration Protect the door against aggressive substances nitre reactions from stone and mortar road salt leaching acids coatings or sealing compounds that have an aggressive effect Cover the door before you begin any plaster or mortar work Spots of mortar cement and plaster or paint sprayers can damage the door surface Notes on installation and operating instructions The diagrams in this manual are not to scale Measurements are given in millimetres Installation and operating instructions 5 WWW Samsondoors co uk OILS Ss 2 AL EOS 4 Scope of supply Standard scope of supply Curtain Top track opening side End cover for top track Cover for top track opening side Floor track opening side Top corner deflection unit End cover for floor track CON WOM AUN Bottom corner deflection unit 9 Top track wall side with motor unit 10 Floor track wall side 11 Closing edge rail 12 Hand held transmitter package 13 Covers for roller housing 14 Bottom guide rollers 15 Fixing brackets
20. control devices e g radio code keypad in the range of sight of the door and at a safe distance from any moving parts of the door The device must be mounted at least 1 5 m above the ground After installation is complete ensure that no door parts extend onto the public footpath or the street 4 Installation and operating instructions VEIRTICO VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 3 General safety advice Caution To avoid personal injury or damage to property the following points must be observed Advice on commissioning the door system All door users must be instructed in the system s operation once it has been installed e Make sure that children cannot play with the door controls Make sure before operating the door that no objects or people are in the danger zone of the door Check all existing emergency commands Never place your hands in a moving door or moving parts Beaware of possible pinching and shear zones in the door system The instructions of EN 13241 1 must be observed Do not open the door by force e Check whether it is possible to operate the door during frost and freezing rain Advice on servicing the motor unit To ensure correct functioning the following points must be checked regularly and repaired when necessary Before working on the door system always disconnect the power supply to the motor unit Ensure that the power supply remains off during the cabling work Perform a che
21. ctions 45 www samsondoors co uk 11 Extended operator functions Menu 6 Function of the impulse command transmitter Setting Impulse command transmitters A6 not active B6 STOP only then standard sequence e uoo LED off LED flashes quickly E d 46 Installation and operating instructions QE s dI de Explanations The impulse command transmitters only give a command when the door is stationary A moving door is stopped by every impulse command transmitter The next command starts the drive system running in the opposite direction OPEN STOP CLOSE STOP OPEN LED pulses LED flashes quickly Factory default setting Not possible VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EO 12 Messages 12 1 Status messages In addition to messages regarding the door position status messages give information regarding the status of the operator system during operation Safety elements D During operation LED 1 serves as a status indicator for the safety elements connected closing edge safety device photocell If the safety element in question is triggered LED 1 lights up whilst it is activated Control elements remote controls During operation and when carrying out component tests LED 7 serves as a status indicator for the control elements connected OPEN CLOSE STOP half OPEN etc If the control element in question is triggered LED 7 lights up whilst it is activated Ed If a re
22. d for doors Installation and operating instructions 3 WWW Samsondoors co uk OILS Ss 2 AL EO 3 General safety advice Caution To avoid personal injury or damage to property the following points must be observed Guarantee A guarantee with regard to function and safety can only be granted if installation is carried out in a competent way and these instructions are followed exactly Ifyou do not observe the warnings you run the risk of personal injury and damaging the door system The manufacturer is not responsible for any damage that occurs if the safety guidelines are not observed Wear and tear parts such as springs bowden cables door cables rollers pulleys tooth belts seals batteries fuses bulbs locks and locking mechanisms are not included in the standard guarantee To avoid installation and operating errors the installation and operation must be carried out exactly according to these installation and operating instructions The door and motor unit may only be operated after reading these installation and operating instructions The door systems are manufactured in accordance with guidelines outlined in the conformity declaration and standards and left the factory without fault and in compliance with safety standards The specialist trader carrying out the installation confirms the correct installation according to DIN EN 12635 by means of his own individual conformity declaration The motor unit must only be opera
23. ended operator functions cceeeeeeeeeeeo o ososososos s 33 11 1 General notes on extended operator functions 0 ccc ccc cece eect teen een 33 11 2 Programming structure for extended operator functions Example for Level 2 Menu 2 34 11 3 General overview of the programmable functions csseeeeeee e 35 11 4 Functions overview for the levels 0 0 0 ccc ccc cece cence eee III mh 37 NIGSSAGGS P P RUTTTTTTT A DP NES Cc P PEDDPR 47 12 2 FEME aO uersoovaviPUdI PTS TANEPUVI a PENES VI DS REESE COLD PEE oa Edad 47 12 3 Rectifying faults oi ace PETRI RURGOUPdE reran RUN GOR EA E A A CR 48 Technical Data cscscsccccccooscccccecesoooocceccecceoosoceseceooooooooooo o D The manufacturer reserves the right to make technical changes to improve the product 2 Installation and operating instructions VEIRTICO Se VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 2 Meaning of symbols Caution Risk of personal injury The following important safety advice must be observed to avoid personal injury Attention Risk of damage to property Please observe the following important safety instructions without fail to avoid damage to property Operational check Installation and programming steps must be checked so that faults can be immediately detected This makes any subsequent work easier Advice tip Reference 3 General safety advice
24. ent impulse Switching to diagnostic mode The controls can be switched to diagnostic mode from either message mode or operating mode Give the P button a short press The controls switch to diagnostic mode and display the last fault 12 3 Rectifying faults 12 3 1 Malfunctions without error messages Error Cause Solution LED 8 does not light up No voltage Check that the mains power supply is operational Check the connection to the mains power supply Thermal overload protection in power Allow the power transformer to cool down transformer was activated Defective control unit Have the operator system checked No reaction on impulse The connection terminals for the Try temporarily disconnecting any key switches or interior push impulse button were by passed buttons that are connected to the control unit Section 8 e g due to a short circuit or flattened remove the cable from socket XB10 insert the shorting plug terminals and look for cabling errors No reaction on impulse Module antenna is not plugged in Connect the module antenna to the control unit Section 10 1 from hand transmitter The hand transmitter coding does not Activate hand transmitter again Section 10 4 correspond to the receiver coding Hand transmitter battery is empty Insert new battery Section 9 1 Defective hand transmitter control unit Have all 3 components checked electronics or module antenna e
25. for longer tracks To avoid injuries the tracks must be secured against falling To achieve sufficient stability at least four fixing brackets must be installed per track this number must be increased To avoid damage to the upper tracks the tracks must not tilt when brought together 10 Installation and operating instructions For each fixing bracket A place two screws in the grooves B of the upper track C e Screw the fixing brackets A by hand to the upper tracks C Position the fixing brackets A on the upper tracks C Align the fixing brackets A with the upper tracks C Tighten the screws Place the upper corner deflection unit D in the upper track C Align the upper track C with the corner deflection unit D flush to the wall Align the upper track C on the lintel using the closing edge rail E Secure the position of the upper track C with struts Check f If the corner deflection unit is located closely DA against the wall the upper track must end at least flush with the door opening VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 6 Installation Drill through the fixing bracket A into the wall Screw the fixing bracket A to the wall Push the upper track C with the motor unit into the upper corner deflection unit D Position the upper track C aloft using the closing edge rail E Secure the
26. g brush P is attached in such a way that it cannot be seen when the door is closed The surface for the sticker on the door curtain must be clean and free of grease Place the closing edge rail O on the tracks Close the door completely by inserting the door curtain as far as it goes into the closing edge rail O Remove the closing edge rail O and slide the curtain further in the direction of door closed Attach the self adhesive sealing brush P from the outside Place the guide roller R with the brush in the slot near the door closing profile H VEIRTICO Installation and operating instructions 15 WWW Samsondoors co uk OILS Ss 2 AL EOS 6 Installation Advice The slot on the last lamella must be fitted with a guide roller R If necessary two guide rollers R must be inserted next to each other here Attach additional guide rollers R in every second slot Screw the guide rollers R securely to the slots Align the guide rollers R flush with the upper edge of the floor track J Place the covers S on the guide rollers R Pull the connector clamp L to the carriage Q Attach the connector clamp L to the carriage Q with two Screws 6 5 Mounting the closing edge rail e Determine the drill points Drill in die grooves of the closing edge rail A Drill diameter Wall 6 0 mm Outside 99 5 mm
27. itches from programming to operating mode Area 2 Menu Each menu sets one parameter The and buttons are used to scroll through the settings within the menus Menus that are not in use are skipped over and are not displayed You can return to the first level via Menu Exit Area 3 Parameters Each function has a maximum of 16 settings The and buttons are used to scroll through the settings for the adjustable parameters Parameters that cannot be adjusted are skipped over and not displayed It is not possible to overshoot by pressing the and buttons Pressing the P button saves the parameters you have set End Programming The programming session can be ended in two ways 1 Via Levels Exit by pressing the P button The controls then switch to operating mode 2 By pressing the P button for longer than 5 seconds at any time and from any area The controls then switch to operating mode If a parameter had been changed it will be saved in the process When the programming session ends all the LEDs light up and then go out one after the other in sequence from 8 to 1 If no buttons are pressed within 120 seconds while in programming mode the controls revert to operating mode A corresponding message is displayed Reference E gt All the available levels and menus are described in the overview of the programmable functions Section 11 3 The messages are explained in Section 12 VEIRTICO In
28. lation and operating instructions 7 WWW Samsondoors co uk OLOSS 29472 16 6 Installation 6 1 Checking the installation conditions Attention To ensure a smooth door run the installation location must be examined Checking the floor Underlay any slanted or uneven brickwork Specifications on the box sticker Element dimensions e 9 4500 x 2051 a x b Measurement check Compare the installation location with the specifications on the box sticker If the installation location does not comply with the specifications Please contact your specialised retailer If the installation location complies with the specifications e Check the scope of supply for completeness If there are any parts missing please contact your specialised retailer before you begin the installation 8 Installation and operating instructions VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 6 Installation The angle between both mounting walls has to be 90 A tolerance of 1 is allowed The slope in the garage must not exceed 1 5 96 y x 100 slope in 96 lt 1 590 VEIRTICO Installation and operating instructions 9 WWW Samsondoors co uk OLOSS 29472 16 6 Installation 6 2 Mounting the upper track Caution accordingly
29. ly be moved at a moderate speed when released The key should not be inserted in the lock of the emergency release device when the door is moving Quick release Disconnect the door from the motor unit Pull the cable A down as far as it can go The door is disconnected from the motor unit and can be opened and closed manually To reconnect the door to the motor unit Pull the cable B down as far as it can go Start the door motor unit The door is connected to the motor unit Emergency release optional To reconnect the door to the motor unit Open the emergency release device with the key Pull the emergency release cylinder C out until the carriage is separated from the toothed drive belt Slide the emergency release cylinder back and remove the key The door is disconnected from the motor unit and can be opened and closed manually 20 Installation and operating instructions VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 8 Connection of control elements Caution Danger of electric shock Before any cabling works begin it must be ensured that the cables are disconnected from the power supply During cabling works it must be ensured that the cables remain disconnected from the power supply at all times e g prevent reconnection Attention In order to avoid damaging the controls The local safety regulations must be complied with at all times It is very important that mains c
30. matic closing timer is activated Level 3 Menu 1 the relay output Level 1 Menu 7 cannot be programmed Q Reference gt I If changes are made in Menus 3 and 4 in Level 1 a new learning run must be carried out for the automatic cut out The learning run procedure is described in Section 10 7 VEIRTICO Installation and operating instructions 37 www Ssamsondoors co uk OU Ss DC 11 Extended operator functions Menu 7 Relay output Setting Function with optional signal light relay only Explanation Advice 1 A7 Signal light Function id B7 Door position OPEN C7 Door position CLOSED D7 Intermediate position OPEN E7 Intermediate position CLOSED F7 Drive system starts running Wiping impulse 1 second G7 Problem H7 Lighting Lighting duration Fia I7 Automatic locking release Drive system is running J7 Lock release Drive system starts running i Wiping impulse 3 seconds K7 Push open security device e LED on jet LED pulses Factory default setting O LED off LED flashes quickly E d LED flashes quickly Not possible 38 Installation and operating instructions VEIRTICO Menu 8 Reset VEIRTICO www samsondoors co uk Operating mode CLOSED door position Start advanced programming RESET programming In Level 1 Change to Menu 3 In Level 1 Change to Menu 8 Change to programming mode Select RESET Confirm reset End programming 11 Que a de Extended
31. mote signal is received LED 7 flashes quickly 12 2 Fault messages Message number is displayed for nO O Malfunctions in the system are indicated by a corresponding T approx 3 seconds O 8 O message number example Message 15 e o The controls switch to message mode e e 2 Pause between messages for e o approx 1 second b o Advice O gu The controls show the message numbers via Operating mode is displayed for e O one or more rhythmically flashing LEDs 3 approx 3 seconds O a Q fexamplniooertngweltage b eg e The message number is found by Qum together the numbers next to the flashing LEDs O 4 Pause between messages for S i Ay During programming all status messages and approx 1 second e S other messages are suppressed The messages O in programming mode are always unambiguous 5 Messages 1 to 4 are repeated The message numbers serve two purposes 1 They indicate why the controls were unable to carry out the drive command given 2 They indicate which components are faulty This facilitates better and faster service on site and only the control components identified as being faulty need be replaced The controls remain in message mode until they switch to operating mode or diagnostic mode VEIRTICO Installation and operating instructions 47 WWW Samsondoors co uk OILS Ss 2 AL EO 12 Messages Switching to operating mode The controls switch to operating mode as soon as they receive a movem
32. n Menu 4 Warning time Menu 5 Start up warning Menu 7 Signal light Menu 2 Intermediate position Menu 1 Programmable impulse input Menu 4 Lighting duration QE s dI de Extended operator functions Factory default setting Signal light No reset Setting 8 Setting 8 Setting 8 Setting 8 Deactivated 2 seconds 1 seconds 0 seconds Door movement Warning flashing Door stoppage off Impulse 180 seconds Installation and operating instructions 35 WWW Samsondoors co uk OILS Ss 2 AL EOS 11 Extended operator functions Level Menu Menu 1 Speed OPEN Menu 2 Soft run speed OPEN Menu 3 Soft run position OPEN Menu 4 Speed CLOSE Level 6 Variable speed Menu 5 Smart run speed CLOSE Menu 6 Soft run speed CLOSE Menu 7 Smart run position CLOSE Menu 8 Soft run position CLOSED Menu 1 Photocell Menu 3 Function of the automatic cut out Menu 4 Operating modes Level 8 System settings Menu 5 Function of the direction command transmitters Menu 6 Function of the impulse command transmitters O LEDoff LED flashes quickly E d LED flashes quickly 36 Installation and operating instructions Factory default setting Setting 16 Setting 6 Setting 16 Setting 10 Setting 6 Operation without photocell OPEN door stops CLOSE door reverses a little OPEN Press and release CLOSE Press and release Not active STOP only then standard sequence Factory default setting
33. n driven past closing prevention f Advice wd Without a connected photocell or closing prevention device only parameter A1 can be adjusted Menu 7 Signal light Setting Door movement Warning Door stoppage A7 flashing OFF Electricity saving B7 lighting OFF Electricity saving C7 flashing flashing D7 lighting lighting E7 flashing lighting F7 lighting flashing Reference D gt i The signal light connection can be adjusted in level 1 menu 7 VEIRTICO Installation and operating instructions 41 WWW Samsondoors co uk ONS Sy TEM 11 Extended operator functions Level 4 Remote programming Menu2 Intermediate position On 20 LED 7 flashes slowly gt press the hand transmitter button gt LED 7 flashes quickly O Level 5 Special function 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 O OWES mu z owo ee o3 o9 e o9e o9 e o9 e o9e oe o9 e o9e o9e o9e oe x9 e e e e e OS o e e O na E e e s tA 9 yeu e e v On Pe e e 9 e 9 hd e o s 9299 969 90699 t Og Oge Oy e Oo 0o 9 9 999 e Menu 1 Programmable impulse input Terminals 1 2 e o oro NEM B1 C1 D1 E1 2 B E m 2 2 e Menu 4 Lighting duration in seconds O o 50 OFF 5 10 15 20 25 30 35 40 50 80 100 120 150 180 255 O Menu 1 Programmable impulse input Setting Function with optional signal light relay only Explanation Advice A1 Impulse normally open contact only B1 Automatic on off normally open contact only C1 closing preven
34. ontrol 868 MHz Digital 302 mini hand transmitter 2 channel Features Safety functions Reference point technology Soft Start Soft Stop Delay safety device Automatic cut out Blocking protection Undervoltage protection Excess travel stop Electronic travel cut out Connection for pushbuttons code buttons and key switches Connection of potential free limit switch message system Error messages 50 Installation and operating instructions QE s dI de VEIRTICO WWW Samsondoors co uk ONS Sy TEM VERTICO Installation and operating instructions 51 WWW Sameon door S co uk OMS ese UTD GG
35. position of the upper track C with struts Screw all fixing brackets A to the wall 6 3 Assembling the floor rails Attention To ensure smooth door operation the floor tracks must be positioned and screwed correctly For the floor tracks A to be able to withstand the loads the floor tracks A must be screwed to the floor at all the designated points in the door way Push the floor tracks A into the corner deflection unit B The water drain C must face outwards VEIRTICO Installation and operating instructions 11 WWW Samsondoors co uk OILS Ss 2 AL EO 6 Installation Place the floor track A under the upper track D Align the floor track A so that it lies plumb beneath the upper track D along its entire length Depending on the conditions on site the position of the upper track may need to be adapted 12 Installation and operating instructions Assembly on an outwards sloping wall Slide the floor track A further into the room until the floor track A is positioned plumb beneath the upper track D along its entire length Assembly on an inward sloping wall Loosen the screws on the upper tracks D Position the upper track D further inwards until the plumb line falls correctly to the floor track A e Tighten the screws on the upper tracks D VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 6 Ins
36. rer e OCC aa va 16 60 Tandis cOVB S socuccucnndesescancsuehe cud DEC RLDERMMU TN RP PARI ST RINARSAUS VO RU DUREE DEN DENS 17 6 7 Assembling the emergency release device optional ccc cece cece eee e eee eee eeeees 18 Quick release and emergency release eere eene 20 Connection of control elements 2E 5253942932492124921299929993224999492292299225 2 1 Hand transmitter 5 b 005 ooo 5 048 bb eos b08 Foes 1 bees x3 aes V TRE d 9 1 Operation and accessories isset bans bes teed P EXRE SE EERCERG HARE RE SEEN ROLE aa aradce d RM E a Seat 23 9 Mati trapsmitter coding sesson dedos EP eu our vss RD adedase ma d reed en andae iter Sd sri tbe qq bed 24 Initial operation o35229 CPP EERIAAGZGPSSPWOSPPPTPEAUEASPIAS PERO PSPCRPDERIT IAM S eO vr DAD 10 1 Connecting the operator system xossavsuosRd ER v REA MESREMSAA TAE EREAF ERU DENM RP RE ATE M SET 26 102 Overview of the control unit amp ossco xs ha Rb EP RR RARE RNRIA senna el Gas GNE ASH NN E IE MEER 26 10 3 Overview of the display functions xusxsxarswzXtb x QuRSESC SEE ORT QELSER A x DES CORP Ex TE EY S 27 10 4 Reference point Locos ve iE ROGER 3 b PER RORDCRR iR ERRUCE Wb ELECTA RC RE eU RACK a ce ado dar RUE de dpa RO 27 TUS JEXDIOSS pogram a eaa e Rien anar E RENE S arOSUR ERROR ERES UR MANO SN RATES RIT REESE 28 10 6 Advanced functions esos saam bt vances us d Rp VoADP ACE OPECUIA GP RrEFEDEPCPNEMEEN UN PENA UR EUN 30 O Ure dec 31 Ext
37. stallation and operating instructions 33 WWW Samsondoors co uk OILS Ss 2 AL EOS 11 Extended operator functions 11 2 Programming structure for extended operator functions Example for Level 2 Menu 2 Levels Menu Parameter O O e v of e Operating Or o On oe ox 3 Q mode Oo O O Level 4 Menu 3 Higher value O re O DX oto T is e e e oa Level 3 Menu 2 Parameter 25 SEC oce o o 09 0 e P gt e 3O o e re ev e e Level 2 Menu 1 Lower value gt e P On o e 5 O50 o gt 10 sec Menu Exit Level 1 Level 2 Mi X o eie OO o O50 P Levels Exit Menu 8 gt 5 sec e e O k 5 i O Q O O Level 8 o E E Ug gt 5 sec programming e LED on jet LED pulses Factory default setting O LED off LED flashes quickly E d LED flashes quickly Not possible 34 Installation and operating instructions VEIRTICO www samsondoors co uk 11 11 3 General overview of the programmable functions Level Level 1 Basic functions Level 2 Operator settings Level 3 Automatic closing timer Level 4 Remote programming Level 5 Special function VEIRTICO Menu Menu 3 Intermediate position OPEN Menu 4 Intermediate position CLOSE Menu 7 Relay output Menu 8 RESET Menu 1 Required driving power OPEN Menu 2 Required driving power CLOSE Menu 3 Automatic cut out OPEN Menu 4 Automatic cut out CLOSE Menu 1 Automatic closing timer Menu 3 Door open duratio
38. supply checked iet r a overloaded at maximum power Ensure that the door moves easily Hs O setting 16 Message 28 Oa O mi Door movement too stiff or irregular Check the path of the door and ensure that the door moves easily jit 50 Door blocked Ik 34 O Automatic cut out is set to be too Have the automatic cut out facility checked by an expert sensitive Section 11 4 Level 2 Menu 3 4 Message 35 iC yet Electronics are defective Have the operator system checked o s 5 5 Ts RE Message 36 o o Shorting plug removed although a stop Connect stop button or insert shorting plug Section 8 jet 5 je button is not connected 8 5 M o eee Ogo Closed circuit is interrupted VERTICO Installation and operating instructions 49 www samsondoors co uk 13 Technical Data VERTICO garage door operator Electrical data Nominal voltage 230V Nominal frequency 50 Hz Power consumption 1 1A Power input operation 0 25 KW Power input stand by 3 9W Operating mode operating time KB 2 Min Control voltage 24V DC Protection category motor unit IP 20 Protection class lI Mechanical data Max push and pull force 600 N Travel speed 140 mm sec Opening time door specific approx 15 sec General data Motor unit dimensions 220x125x395 mm Weight 3 8 kg Temperature range 20 to 60 C Supply package Motor unit VERTICO with integrated electronic controls Multibit remote c
39. t CLOSE Door movement CLOSE A1 Operation without photocell B1 Door reverses completely not active C1 not active Door reverses completely D1 Door reverses completely Door reverses completely e LED on jet LED pulses Factory default setting O LED off LED flashes quickly E d LED flashes quickly Not possible 44 Installation and operating instructions VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 17 Extended operator functions Menu 3 Function of automatic cut out Setting Door movement OPEN Door movement CLOSE A3 Door stops Door reverses a little B3 Door reverses a little Door reverses a little C3 Door stops Door reverses completely D3 Door reverses completely Door reverses completely Menu 4 Operating modes Setting OPEN CLOSE Ad press and hold press and hold B4 automatic closing press and hold C4 press and hold automatic closing D4 automatic closing automatic closing 1 Door reverses a little The drive system moves the door a short distance in the opposite direction in order to free an obstacle 2 Door reverses completely The drive system moves the door to the opposite end position Menu 5 Function of the direction command transmitter Setting Direction command transmitters Explanations The direction command transmitters only give a command A5 not active when the door is stationary A moving door is stopped by every direction command B STOP only transmitter VEIRTICO Installation and operating instru
40. tallation Fix the floor track A e Mark the drill points Drill through all openings in the guide grooves E Drill through all the indentations on the sides F Screw the floor track at all fixing points Tip For concrete foundations the following fixing materials are suitable for a particularly secure fixing Fixing points in the guide grooves E Fischer Universal frame fixings Type FUR 10x80 T A4 counter sunk Torx Fixing points in the indentations F Fischer Universal frame fixings Type FUR 10x80 SS A4 hexagonal head with stainless steel washers 6 4 Installing the curtain Attention To avoid damage to the door the following points must apply The screws of the fixing brackets A may only be slightly loosened otherwise the upper track B can fall down The brush inlay D of the upper track B must abut the corner deflection unit C The door curtain G must be protected against scratches gt All the rollers of the curtain G must run in the groove l The bottom of the curtain G must run between the floor track J and the wall The assembly aid F is an optional extra available from Alulux The assembly aid F facilitates the insertion of the curtain in the corner deflection unit C e Mark the exact position of all fixing brackets A on the upper track B Unscrew the screws on the fixing bracket A VEIRTICO Installation and operating instructions 13
41. ted in spaces The guarantee for the door and motor unit is only valid if original accessories are used These installation and operation instructions must be handed over to the end user who should store them carefully Maintenance must be performed on the door and motor unit before start up and at least once a year thereafter All maintenance work must be documented Intended use This door system is intended exclusively for domestic use on average 2000 cycles a year and is not licensed for continuous operation Installation tips The system must always be installed by at least two people Ensure that the floor is at its finished level Ensure that the walls and ceiling are already plastered The travel path of the door must be free of all obstructions e g nails sockets cables etc to avoid damage to the door Ensure that suitable fixing material is available for the foundation Prefabricated garages must be drilled using a depth stop Prefabricated garages with a ceiling thickness of 60 mm may not be drilled any deeper than 35 mm Before beginning cabling work disconnect the motor unit from the power supply Ensure that the motor unit remains disconnected from the power supply during cabling work Observe the local safety regulations The power cable and the control cable must be laid separately The control voltage is 24 V DC Only mount the motor unit when the door is closed Mount all pulse generators and
42. tion CLOSE BO Set using the OPEN and CLOSE buttons Menu 8 Soft run position CLOSED GeO Oz 50 Set using the OPEN and CLOSE buttons Reference If changes are made in Menus Menus 1 2 3 4 6 and 8 in Level 6 another learning run must be carried out for the automatic cut out The learning run procedure is described in Section 10 7 VEIRTICO Installation and operating instructions 43 11 Level 8 System settings www samsondoors co uk Extended operator functions Que SZ aA F 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 e elo o o o o oo lern lenen evo ero ero ennen ero ero a e e On O e e e O e e c e s e 9 e Or 529 xc e e e e e e OGO O69 oo 069 O60 060 Ob oje O49 Oe Hee e 0 e 0 e480 e Menu 1 Photocell o O or h B B1 C1 D1 e Menu3 Automatic cut out e e of 5x A3 B3 C3 D3 E E 2 z PO Menu4 Operating modes e e e e A4 B4 C4 D4 2 z z z O Menu 5 Function of the direction command transmitters e e oz 50 MENS B5 E z E E C Menu6 Function of the impulse command transmitters O e e e o B6 z z 4 2 2 3 O Attention Ifa photocell is connected it is automatically recognised by the controls after MAINS ON The photocell can be reprogrammed later Menu 1 Photocell Photocell 1 Photocell 2 Setting Connection XP020 Connection XB01 Terminal 70 71 Door movemen
43. tion device only in CLOSE direction normally closed contact only D1 Impulse OPEN induction loop normally open contact only E1 Stop normally closed contact only Reference E gt i The programming of the special function is dependent on terminal XB01 Terminal XB01 is described in Section 8 The lighting duration programmed is only active when the relay output Level 1 Menu 7 is programmed for lighting H7 e LED on jet LED pulses Factory default setting O LED off LED flashes quickly E d LED flashes quickly Not possible 42 Installation and operating instructions VEIRTICO WWW Samsondoors co uk OILS Ss 2 AL EOS 11 Extended operator functions Level 6 Variable speed 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 O see x 8 e e e e e e T e we lence ofo of ofe ofe ofe ofe oe 0 0 ofe o e ofe o e o e 0 Oye Vg Rw 812 EUN e On o On 20 e Or om On 5e On 5e e x e vi e Or c0 e E e ee ee Menu 1 Speed OPEN in increments eve Or o 7 8 9 10 11 12 13 14 15 16 O Menu 2 Soft run speed OPEN in increments OrTO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Menu 3 Soft run position OPEN on MK Set using the OPEN and CLOSE buttons Menu4 Speed CLOSE in increments Menu5 Smartrun speed CLOSE in increments e e e o 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 O xO Menu 6 Soft run speed CLOSE in increments uw 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Menu 7 Smart run posi
44. xpress programming procedure is carried out The photocell will only be recognised automatically by the controls if this is the case Otherwise the photocell must be programmed after installation 22 Installation and operating instructions VEIRTICO WWW Samsondoors co uk OLOSS 2 2 76 9 Hand transmitter 9 1 Operation and accessories Caution Children are not allowed to operate the hand transmitters Before operating the hand transmitter make sure that there are neither persons nor objects in the operating range of the door Hand transmitter A Operating button large B Operating button small C Battery transmission control light D Transmission socket Another operator system can be operated using the second operating button Change batteries E Back of hand transmitter F Battery 3V CR 2032 Open the back of the hand transmitter E e g with a coin Change the battery F and observe correct poling Fixing accessories for hand transmitter optional Wall support for hand transmitter Visor clip for attaching the hand transmitter to a visor in a car Si Reference The procedure for programming hand transmitters remote controls to operate the operator system is described in Section 10 4 VEIRTICO Installation and operating instructions 23 WWW Samsondoors co uk OILS Ss 2 AL EOS 9 Hand transmitter 9 2 Hand transmitter coding Transfer the coding Using this function it
Download Pdf Manuals
Related Search
Related Contents
Samsung EPEL SBS with Twin Cooling, 495 L, Silver Brugervejledning USER MANUAL TAURUS UL XP V A U D E .C O M Sears 625.3438 User's Manual SIGNUM Manual Broilmaster DPA104 Grill Accessory User Manual 取扱説明書 MANUAL DE INSTRUCCIONES EQUIPO PARA SHARP MANUEL DE SERVICE BENDIX PNU-180F User's Manual Copyright © All rights reserved.