Home
bioBidet BB-1000R Use and Care Manual
Contents
1. Do not stand or sit on the seat coverlid It is not designed to support a user s a body weight Do not bang the seat and lid J m gt gt O o o Do not strain or push the connected hose and tube connecter it may cause water leakage Never drop or insert any object into any opening or hose Use BIO BIDET SUPREME BIDET SEAT only as described in the operating instructions Never use while sleeping or drowsy Do not use while bathing Be careful so that BIDET SUPREME 7 BIDET SEAT does zx not become stained with excrement and urine Drain the water from BIO BIDET SUPREME BIDET SEAT and unplug the power if it is not going to be used for an extended period of time This will help prevent the unit from freezing over and in good condition SAVE THESE INSTRUCTIONS CAUTIONS BEFORE INSTALLATION WIRING REQUIREMENT BIO BIDET SUPREME BIDET SEAT MUST BE PLUGGED into a regular voltage North America 120V AC 60Hz Europe 230V AC 50Hz and the rated power consumption is 660W 660W Grounded GFCI outlet In locations where only a standard two prong outlet is available it is the responsibility of the user to install a grounded three prong outlet Using a higher voltage is dangerous and may result in a fire or other accident BIO BIDET is not responsible for damage resulting from the use of BIO BIDET SUPREME BIDET SEAT on othe
2. 4 UC lifestyle Upgrade SUPREME BIDETSEA T Installation Manual and Operating Instructions i ete d gt BB 800 BB 900 1000 10k W b T W m This Product should be installed according to this manual m Please read this manual carefully and install properly Please keep this manual forfuturer eference m Please register Warranty for pr aper service UC SUPREME BIDET SEAT Thank you for purchasing BIO BIDET Supreme Bidet Seat This unit is manufactured tor household use Contents ES 5 GENERAL CAUTIONS gt JJ BEFORE INSTALLATION gt ee lt m OPERATION BASIC OPERA TON DETAILS E tee ee 4 uan DETAN D L gt O lt SS SS WATER DRAINING E TROUBLE 20 RE SBEGIEIKC A TIONIS eee INFORMATION TO THE USER e WARRANT 22 UCI ime T Installation Manual and Operating Instructions e IMPORTANT SAFEGUARDS GENERAL CAUTIONS READ ALL INSTRUCTIONS BEFORE INSTALLATION AND USE The following terms are used in this manual to indicate hazards of varying degrees of severity indicates an imminently hazardous situation which if not avoided will result in death Or Serious Injury indicates potentially haz
3. Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment e OR Note The manufacturer is not responsible for any Radio or TV interference caused by unauthorized modifications to this equipment Such modifications could void the user s authority to operate the equipment WARRANTY UCI Inc Limited Warranty This limited warranty gives you specific legal rights and you may also have other rights that may vary from state to state or according to other conditions General Limited Warranty Covered The Manufacturer UCI Inc will warrant to the original retail buyer only which fails in normal use and within the applicable periods specified below following the terms of this warranty UCI Inc replacement will be warranted to the original purchaser of the products The Parts Warranty If the parts fail within Twelve 12 months after original installation following the installation manual and normal operation UCI Inc will furnish a replacement part s gt lt EN mi gt 2 m Installation Manual and Operating Instructions SHOWER TOILET SEAT DiOBidet Will be not Covered by this Warranty Defects and or malfunctions from failure to properly install operate and or maintain the unit in accordance with the installation manual Damage from abuse fire flood freeze and any other act of God Damage
4. MAINTENANCE CLEANING THE NOZZLE e When the Posterior Wash button in simple operation panel is pressed for 3 second without occupying the seat the nozzle can be cleaned with a toothbrush e After cleaning the nozzle push the Stop button in simple operation panel once again and the nozzle retracts itself CLEANING THE BODY OF UNIT e When you clean the body do not use thinner benzene NaClO It causes defects to the surface of unit e Please use a wet cloth when you clean the unit e Do not spray water directly on the unit e When you dean the unit please disconnect the power plug CLEANING THE STRAINER The product BIO BIDET SUPREME BIDET SEAT will not operate properly if the strainer is clogged Please clean the strainer regularly 1 Close the shut off valve 2 Flush the toilet to empty the water reservoir 3 Unscrew the water filter nut 4 Clean the strainer with a small brush or water 5 Re screw the water filter nut 6 Open the shut off valve SHOWER TOILET SEAT WATER DRAINING DRAIN THE WARM WATER TANK IN THE UNIT If you do not use the product for long time please drain water from the warm water tank 1 Disconnect the power plug 2 Close the shut off valve 3 Press the drain lever until the water is completely drained from the unit s water tank 4 To re supply water after draining open the shut off valve
5. lt IDENTIFICATION 6 MAIN UNIT Warning Lable Posterior Wash Nozzle Caution Lable Feminine Wash Nozzle Lid Enema Function Nozzle Simple Operation Panel Operation LED Window Deodorizer Dryer Outlet Posterior Wash Nozzle Feminine Wash Nozzle Drain Unit Separation Button Enema Function Nozzle Digital Occupied Sensor Heated Seat Water Supply Tube to BIO BIDET Shower Toilet Seat 0 0 Washer 2 pcs Deodorizer Filter Unit 2 eem f 6 5 555555505556 gt 555550 0994 Use Semipermanent 062626006262 525252502526 T Valve and Washer Cone Packing 2 pcs DEODORANT Pree CARBONATE Sheet Instruction Operating IEEE Sheet Manual Mounting Bolts 2 pcs Water Supply Tube to Toilet Fresh Tank Simple Guide Installation User Nuts 2 pcs Spanner M var Battery 2pcs aD e IN 1 5V uick Release plate j 3 8 Spare Nut li m FIX Screw 8 1 E ai With Packing Remote Remote Blocking 3pcs p contro control Fixed Panel O UCI Installation Manual and Operating Instructions SHOWER TOILET SEAT 4 OPERATION BASIC biOBidet F MININE WASH gt O lt Adjust the water and seat temperature 4 levels Adjust the oscillation function and nozzle position 5 levels Adjust the water pressure and warm air dryer temperature Power Saving mode b
6. Do not drink the drained water Do not insert finger into the drain hole Before draining unplug the power cord and wait 30 minutes until the unit has cooled down A MAINTENANCE FOR WINTER SEASON e Please check the power cord whether plugged in or not Keep the water temperature on Middle or High Level to prevent water from freezing If you do not use the unit for long time please disconnect the power plug and drain the water ci Installation Manual and Operating Instructions 49 gt lt mr mi gt 2 e m TROUBLE SHOOTING The washing water is not sprayed The unit is not operating 1 The water tank is not filled 2 The shutoff valve is closed 3 Freezing inside the main unit or the water supply pipe 1 Disconnected the power cord 2 The seat is not occupied 3 The battery of remote controller is exhausted 1 Wait about one minute 2 Press the desired washing button once again 3 Turn on the shutoff valve to open 4 Heat the room for about two hours Operating the unit while parts are frozen will cause a malfunction 1 Connect the power cord 2 Check the power supply system in your house 3 Occupy the seat The unit has an occupied sensor 4 Replace the battery Water is leaking The washing water pressure is weak 1 Check the water supply system 1 The water pressure level is set to LOW 2 The
7. Bidet A burn occurs when the skin has been exposed to high temperatures However a low temperature burn may occur when the skin has been in contact with an object at relatively low temperature about 104 Close supervision is necessary when this product is used by on or near children or invalids Keep the cord away from heated surfaces And keep any flammable materials away from the BIO BIDET SUPREME BIDET SEAT If using any chemical toilet bowl cleaner be sure to wipe up any spills that splash onto BIO BIDET SUPREME BIDET SEAT Do not use benzene or any acid chemical detergent Only neutral detergent permitted Never operate this product if it has a damaged cord or plug BIO BIDET SUPREME BIDET SEAT must be connected to a standard voltage power source Do not connect power cord if the cord is damaged or broken Do not plug the unit into a loose electric outlet Please disconnect the power cord when you clean the BIO BIDET SUPREME BIDET SEAT or detach it from toilet bowl Do not supply electrical power to the unit until the plumbing installation work has been completed m m gt gt lt Never operate this product if it Do not obstruct or is not working properly if it has put anything into the been dropped or damaged or dry air outlet Do not dropped into water Return the apply excessive force product to a service center for to the shower nozzle 22 examination and repair
8. F Ambient Temperature 3C 40 C 37 4 F 104F gt lt mi a gt lt C m a W 475mm 18 7 inch W 475mm 18 7 inch L 525mm 20 6 inch L 493mm 19 4 inch 185mm 7 28 inch 185mm 7 28 inch 5 2k Weight Ibs eevee creda Installation Manual and Operating Instructions INFORMATION TO THE USER This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WARNING
9. ONOMY 1 feature drops the water temperature and seat temperature to about 32 C 90 when the seat is not in use 2 mi gt 2 lt ECONOMY 2 ECONOMY 2 Intelligent Economy Function records the main time the family use it for 4 days after installation Then the unit sets up the Power On and Off Time The ECONOMY 2 feature drops the water and seat temperature to about 32 C 90F When the seat is in use during this mode the settings are returned to their original levels After using the unit is returned to ECONOMY Mode NOZZLE CLEANING Automatic BIO BIDET SUPREME BIDET SEAT has an automatic nozzle self cleaning function that works before and after each operation 9 NOZZLE CLEANING Manual e Nozzle can be cleaned manually by pressing CLEANSING 1 Posterior Wash button for 3 seconds without being occupied on the seat and nozzle will come out Press CLEANSING 1 Posterior lt button for 3 seconds again to return nozzle to stand by mode eevee creda Installation Manual and Operating Instructions SHOWER TOILET SEAT DiOBidet Place bolt guide with bolt in quick Place main unit aligning to toilet release plate and slide into designated seat mounting holes groove at rear bottom of main body gt 12 7 Cone Packing gt Washer BEI Securly tightening mounting bolts Connect water supply flexible hose to
10. ardous situation which if not avoided could result in death or serious injury C AUTI ON indicates potentially hazardous situation which if not avoided may result in minor or moderate injury or in damage to the product or other property NOILVdVdidd Do not open the product to repair or remodel Only qualified service personnel should service BIO BIDET SUPREME BIDET SEAT Do not use attachments not recommended by the manufacturer Do not splash water on BIO BIDET SUPREME BIDET SEAT Do not install in a location exposed to excessive moisture that condensation forms on the BIO BIDET SUPREME BIDET SEAT surface To avoid damage to electronic components due to high levels of humidity provide adequate ventilation opening via an opened window and or door when bathing The BIDET SUPREME BIDET SEAT must be grounded Connect the grounding wire properly to the grounding terminal Refer to the grounding instructions An approved Ground Fault Circuit Interrupt GFCI must be used Do not touch the power cord with wet hands Do not reach eeoeoooooU Do not plug in the power cord before connecting the water supply hose Connect the BIO BIDET SUPREME BIDET SEAT to cold water supply pipe carrying potable water Do not connect to an industrial water supply line that does not carry water of drinking quality This will negatively effect hygiene and performance About Low Temperature Burns SHOWER TOILET SEAT DiO
11. d in sketches B and C may be used to connect this plug to a 2 pole receptacle as shown in sketch B if a properly grounded outlet is not available The temporary adapter should be used only until a properly grounded outlet sketch A can be installed by a qualified electrician The green colored rigid ear lug or the like extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adapter is used it must be held in place by the screw ADAPTER Di D TAB for METAL SCREW Grounding Screw B C GROUNDED OUTLET N i ADAPTER 3 58 7 0 m m u GROUNDING PIN GROUNDED OUTLET BOX Figure 1 IMPROPER GROUNDING CAN RESULT IN A RISK OF ELECTRIC SHOCK N DANGER Electric wiring has to be done in accordance with all local codes or in the absence of local codes with the National Electrical Codes The use of an extension cord is not recommended or advised If it is necessary to use an extension cord use only a three prong extension cord and a three slot built in GFCI receptacle that will accept the plug on BIO BIDET SUPREME BIDET SEAT The marked rating of the extension cord should be equal to or greater than the electrical rating of the unit 10amp Consult a qualified electrician or service person if you are not sure whether the unit is properly grounded eevee creda Installation Manual and Operating Instructions Go m JJ m gt gt
12. e Drain the toilet tank completely Remove the water supply hose to toilet tank Flexible Tube NOILVTTVLSNI Use the Spanner Connect T Valve e Remove existing supply tube from fresh tank e Angle Stop Valve is standard 1 2 in size If it is 3 8 use the 1 2 to 3 8 conversion nut kits with packing before connecting the Angle Stop valve Install T Valve on top of Angle Stop Valve w CD S 3 8 Spare Nut LU Cre ian CO N Use the Spanner Installation Manual and Operating Instructions Removing the existing seat and lid e By using a wrench spanner or other proper tool release the nut on both sides of existing toilet to remove the toilet seat and lid One of flexible tube connects from top of T Valve to toilet tank Flexible Tube Use the Spanner SHOWER TOILET SEAT DiOBidet MASSAGE Rhythmic Wash e When using Posterior Wash Enema Wash or Feminine Washing pressing MASSAGE Rhythmic Wash button will provide pulsating spray In addition the water pressure is adjustable by pushing High or Low and MASSAGE simultaneously Auto Setting of Massage Without being occupied press MASSAGE button for 3 seconds to set up Auto Setting of MASSAGE Auto Setting of MASSAGE Without pushing MASSAGE button when using CLEANSING this Massage function will be operated automatically ECONOMY Power Save Mode ECONOMY 1 The EC
13. el ee Cio Ci Qi e Level1 4 Deodorizer Deodorizer Deodorizer OFF Air velocity of Air velocity of Air velocity of wind wind wind On Using gt On Using gt On Using gt Low Speed Low Speed High Speed After using gt After using After using gt Low Speed High Speed High Speed OSCILLATION Nozzle Move Function e When using Posterior or Feminine Washing press a OSCILLATION Move button will provide oscillating spray for much wider cleansing This function is not available during Enema Wash In addition the oscillation can be adjusted to the desired position by pressing OSCILLATION Move and 2 Front or Rear simultaneously e f you push OSCILLATION MOVE again the oscillation will be stop automatically Auto Setting of Oscillation Without being occupied press OSCILLATION MOVE button for 3 seconds to set up Auto Setting of Oscillation Auto Setting of Oscillation Without pushing Move button when using Posterior or Feminine Washing this oscillation function will be operated automatically alee S Installation Manual and Operating Instructions INSTALLATION N CAUTION BEFORE INSTALLATION Please do not plug in before installation e If you need an electric power system or extension please consult a qualified electrician STEPS Shut off the water supply to the existing toilet tank by closing the angle stop valv
14. ozzle comes out and sprays STEP 2 The stream of water is set to the posterior center STEP 3 Press water pressure High amp Low button amp O and adjust the water pressure STEP 4 If you feel that the water has filled you up a bit just wait for a minute and push the water and feces out If you do not push out the water in a rectum completely you may feel unwell e CLEANSING 3 Feminine Wash 2 Press Feminine Wash X automatically nozzle comes out and sprays warm water to feminine area If you press Oscillation Move the nozzle moves back and forth automatically Nozzle stops moving when the switch is pressed again and It automatically stops after two minutes aie ce Installation Manual and Operating Instructions SHOWER TOILET SEAT DiOBidet WARM AIR DRYER Press dry air comes out Middle of operation you can adjust the warm air temperature with High and Low button It will automatically stop about 3 minutes later STOP Press this button to stop in middle of operation WATER PRESSURE ADJUSTMENT AND DRY TEMPERATURE ADJUSTMENT e After sitting down on the seat the LED lamp Gama for water pressure should light at 3 levels cmm You can adjust the water pressure with High and Low button Adjust the Warm Air Dryer temperature with High and Low button In addition the unit memorizes the air tempe
15. r than specified voltage or operating it without proper grounding NS mU DS Installation Manual and Operating Instructions SHOWER TOILET SEAT DiOBidet BIO BIDET SUPREME BIDET SEAT must be on a separated circuit No other appliance should share the circuit with BIO N WARNING BIDETSUPREME BIDET SEAT Sharing a circuit could cause the branch circuit fuse to blow or the circuit breaker to trip Continuous usage under these conditions could result in fire or property damage GROUND INSTRUCTIONS 1 BIO BIDET SUPREME BIDET SEAT has a three prong grounding plug which must be plugged into an outlet that is properly installed and grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current If repair or replacement of the cord or plug is necessary do not connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire Check with a qualified electrician or serviceman if the grounding instructions are not completely understood or if in doubt as to whether the product is properly grounded m gt gt Pa 2 This product is for use on a nominal 120V circuit and has a grounding plug that looks like the plug illustrated in sketch A in Figure 1 A temporary adapter which looks like the adapter illustrate
16. rature of prior use Basically the uint memorizes the water pressure level of prior use But when user put the simple operation panel the first water pressure always should be fixed on middle level When user does not use remote control for 10 seconds the LED lamp CAUTION will turned off in order to save the battery power WARM WATER TEMPERATURE AND SEAT TEMPERATURE ADJUSTMENT The temperature of water and seat are adjustable to the desired level by pressing WATER v 9 and SEAT amp button WATER TEMPERATURE Gp QED Gm Room temperature approx 93 2 F 34 C 98 6F 37 C 104 F 40C SEAT TEMPERATURE One 3 Oil 9 ane Room temperature approx 93 2F 34 C 98 6F 37 C 105 8 41 Jg mi gt eevee creda Installation Manual and Operating Instructions Q mi gt O 2 OPERATION DETAILS NOZZLE POSITION ADJUSTMENT e Nozzle position is adjustable to the desired position by pressing Front or Rear 2 button from 1 to 5 positions After using product the nozzle should return to position 3 DEODORIZER e The deodorizer is activated when the unit is occupied After using the unit it Will automatically stop about 1 minute later e The deodorized air velocity of wind is adjustable to the desired level by pressing STOP and WATER v3 simultaneously 1Level 2Level 3Level Alev
17. resulting from unauthorized alterations attachments and or repairs If the product was not installed properly to residential water closets Damage from installing the unit in an environment with animals mice or insects Damage caused by excess moisture or from water clogging the water closet Damage from not being installed in accordance with all applicable local codes ordinances and good trade practices 8 Color fading due to use in wrong environments 9 Damage from consumable chemicals 10 The warranty will not be covered without providing the date of purchase with original receipts 11 Damage from misuse due to not following the installation manual 1 UW uU WARRANTY REGISTRATION To ensure your warranty protection you must complete and return this card to UCI Inc within 10 days after date of purchase Model h 5A Serial Number gt 2 Service c Department gt Country rm Fax Dealer Company Head office Dealer Code 205 Berg Street Address eee Algonquin Illinois 60102 Tel 847 854 7292 Fax 847 854 1296 eevee creda Installation Manual and Operating Instructions e lifestyle upgrade www biobidet com UCI Inc Head office Algonquin Illinois 60102 Tel 847 854 7292 1 Fax 847 854 1296
18. strainer is clogged 1 If water is leaking from the main unit call the service center or the place you purchased 1 Set the water pressure to HIGH 2 Clean the strainer The washing water Is not warm The seat and dryer 15 not warm 1 The water temperature is set to LOW 2 Continuous operation has depleted the supply of warm water 1 The seat amp dryer temperature is set to LOW aie DS Installation Manual and Operating Instructions 1 Set the water temperature to HIGH 2 Wait about three minutes 1 Set the seat amp dryer temperature to HIGH SHOWER TOILET SEAT SPECIFICATIONS DIOBidet Power Rating AC 120V 60Hz 660W Water inlet Direct Inlet flow type type Water inlet pressure 0 4 7 5 kgf cm 5 69 psi 106 7psi Power cord 1 2m 4 feet Posterior Wash Max 1 2 2 min 0 32 GPM Feminine Wash Max 1 2 2 min 0 32 GPM Water Pressure E Adjustable ids Warm Water o B TODOS Room Temp 40 C Room Temp 104 F Heater 600 W Safety Devices Thermal fuse Thermal switch Float switch Temperature Room Temp 41 C Room Temp 105 8 Heated Seat Heater Satety Device Thermal fuse Adjustable Dry Temperat Dry Temperature Room Temp 45 C Temp 45 C Warm Heater Air Dryer 05007 Device _ Safety Device Device Themal fuse bimetal Enema Function Deodorizer Remote control Inlet water temperature 35 C 374 F 95
19. utton bioBidet SERVICE INQUIRY 877 339 5214 Stop Posterior Wash Feminine Wash e When you sit on the unit please sit down on the central position in order to activate the sensor e After an extended wash allow about three minutes for water to reheat eevee creda Installation Manual and Operating Instructions OPERATION DETAILS 6 PREPARATION Open the shut off valve and check for any water leaks e Plug the unit into the proper power source and turn it on e The water tank will be filled after pushing a Wash 7 water tank is filled the buzzer sounds Beep OPERATION amp 3 button When the SIT DOWN ON THE SEAT e When you sit down on the seat the LED lamp on the control panel will light up e When the digital sensor on the seat is activated the operation LED window on the unit will light Occupied sensor simultaneously Deodorizer will start working B mi gt STOP Press this switch to stop in middle of operation CLEANSING e CLEANSING 1 Posterior Wash gt Press Posterior Wash 7 automatically nozzle comes out and sprays warm water to posterior If you press Oscillation Move the nozzle moves back and forth automatically Nozzle stops moving when the switch is pressed again It automatically stops after two minutes CLEANSING 2 Enema Wash STEP 1 Press Enema Wash X automatically n
20. with supplied cone packing and the unit plastic washer 4 gt gt lt Cone Packing gt gt gt r Washer Nut N Nas Use the Spanner Connect ground wire from T Valve to BIO BIDET SUPREME BIDET SEAT Check for any water leakage eevee creda Installation Manual and Operating Instructions 6 INSTALLATION Insert the deodorant catalyst into the unit How to change the deodorant catalyst Check the deodorant package Deodorant Deodorant case Follow the below photos to change the deodorant NOILVTTVLSNI Peel off adhesive protection to use self adhesive Place supplied batteries and close the cover Or mount on the wall using supplied Screws Screw mounting holes 7 UCI lt n saas Installation Manual and Operating Instructions SHOWER TOILET SEAT bioBidet 7 DETACHMENT If move or clean the toilet please separate the BIO BIDET SUPREME BIDET SEAT from toilet bowl Disconnect power e Shut off water supply Empty water tank using drainage Slide out main unit from quick release plate while pushing drainage as illustrated below N Do not turn upside down NOLLVTIVISNI Disconnect the tube and T Valve from unit Refer to page 14 Installation Manual and Operating Instructions gt Z mi Z gt Z A rTi