1. e v B A Green ground wire B Ground screw Failure to follow these instructions can result in death fire or electrical shock 8 Plug into a grounded 3 prong outlet AIR CONDITIONER USE Operating your air conditioner properly helps you to obtain the best possible results This section explains proper air conditioner operation IMPORTANT m If you turn off the air conditioner wait at least 3 minutes before turning it back on This prevents the air conditioner from blowing a fuse or tripping a circuit breaker m Donottry to operate your air conditioner in the cooling mode when outside temperature is below 65 F 18 C The inside evaporator coil will freeze up and the air conditioner will not operate properly NOTE In the event of a power failure your air conditioner will operate at the previous settings when the power is restored 1 Set the Exhaust control See Exhaust Control on some models 2 Set the Fan Control to desired setting See Fan Control for your model 3 Turn the Thermostat control to a mid setting See Thermostat for your model Exhaust Control on some models Set the Exhaust control to CLOSED for maximum continuous cooling The Exhaust control set OPEN allows you to draw stale or smoky air from the room m OPEN to exhaust room air to the outside m CLOSED to circulate room air CLOSED o OPEN NOTE
2. 4 ADVERTENCIA A Peligro de Peso Excesivo Use dos o m s personas para mover e instalar el acondicionador de aire 0 No seguir esta instrucci n puede ocasionar una E B lesi n en la espalda u otro tipo de lesiones Quite los materiales de empaque A Alambre verde de conexi n a tierra B Tornillo de puesta a tierra m Quite y desh gase debidamente de todos los materiales de Tire de la manija para deslizar el acondicionador de aire fuera embalaje Quite las cintas y los residuos de goma del del gabinete Coloque el acondicionador de aire sobre el acondicionador de aire antes de encenderlo Frote un poco cart n de detergente l quido para vajillas sobre el adhesivo con los dedos Limpie con agua tibia y seque m No use instrumentos filosos alcohol para fricciones l quidos inflamables o productos de limpieza abrasivos para eliminar los restos de cinta o goma Estos productos pueden da ar la superficie de su acondicionador de aire m Trate el acondicionador de aire con cuidado Saque el acondicionador de aire de la caja y col quelo sobre el cart n 2 Quite el tornillo de embalaje de la pared lateral del gabinete A ASAS N A Manija N Y NOTA No levante empuje jale ni remueva ning n poliestireno N expandido espuma del interior del acondicionador de aire No N es un material de empaque A Trate el acondicionador de aire con cuidado A Tornillo de embalaje Aseg rese de que el gabinete del acondici
3. screws 2 screws 6 D 8 x round head G Top channel screws 3 H Side curtains 2 NOTE Installation parts are supplied for double hung windows up to 40 101 6 cm wide A special Wide Window Kit is available from your dealer or service center See Accessories IMPORTANT Observe all governing codes and ordinances Check the location where air conditioner will be installed Proper installation is your responsibility Make sure you have everything necessary for correct installation The location should provide m Grounded electrical outlet within 4 ft 122 cm of where the power cord exits the air conditioner NOTE Do not use an extension cord Free movement of air to rooms to be cooled A large enough opening for the air conditioner Adequate wall support for weight of air conditioner Air conditioner weighs between 80 and 110 lb 36 3 to 49 9 kg NOTE Cabinet louvers must not be obstructed Air must be able to pass freely through the cabinet louvers A S S N SN S N A Cabinet louvers Window installation on some models Window opening measurements m Width 28 71 1 cm minimum to 40 101 6 cm maximum m Height 161 41 3 cm minimum A 28 71 1 cm minimum to 40 101 6 cm maximum B 1674 41 3 cm minimum Through the wall installation The wall opening measurements should be m Height 16 40 6 cm plus twice the thickness of wood used to build frame m
4. 1186897B AIR CONDITIONER This guide contains useful information Read it carefully before using your room air conditioner For questions about features operation performance parts accessories or service call 1 800 253 1301 in the U S A ACONDICIONADOR DE AIRE Esta gu a contiene informaci n til L ala cuidadosamente antes de usar su acondicionador de aire de habitaci n Para consultas respecto a caracter sticas operaci n desempe o partes accesorios o servicio t cnico llame al 1 800 253 1301 en los EE UU Table of Contents INdiCe ceccccecsesecsesersererserees 2 TABLE OF CONTENTS AIR CONDITIONER SAFETY 2 ccssccsseeesseeesseeeeseeesseeesseneeneeeesees 3 INSTALLATION REQUIREMENTS csssccseeecsseesseeesseeesseeesseees 3 Tools a diPatS art did ad 3 Location Requirement ooooccccnccccnccononcconocnnnncnnnncnnnnccnnoncnnacnnnncnnns 4 Electrical Requirements ccccccceeseceeceeeeeeseeeeeeeeeeeeeeseeeeeeeeeees 4 INSTALLATION INSTRUCTIONS ccsseesseeeesseesseeesseeenseenseees 5 UINPACKINO ani neiii Paden itd dines 5 Installing Air Conditioner oococnconccnnnnnonncnnccnnrcnnrcnnrrrnrnrrrrncnnrnr 6 Position the Air Conditioner Cabinet oconcocincccinncccnncccnncccnncccnnnnons 7 Complete Installation cccceccceseceeceteeeeneeeeneeeeeeseaeeseaeesseeeesaees 9 AIR CONDITIONER USE ccseccseeeeseeeeseeeeseeeesseeenseeesseeessneeees 10 Starting Your Air Conditi
5. El Control de Respiradero est en OPEN Abierto en algunos modelos Fije el control de Respiradero en la posici n CLOSED Cerrado para un enfriamiento y o calefacci n m ximo El control de Thermostat Termostato no est en una posici n lo suficientemente fr a Ajuste el control de THERMOSTAT a una posici n m s fr a girando la perilla en la direcci n de las manecillas del reloj Ponga el control de FAN en TURBO COOL El acondicionador de aire en el modo de calefacci n no tiene la capacidad suficiente de BTU h para los requerimientos de calefacci n de la habitaci n No use el acondicionador de aire como fuente principal de calor Se filtra agua del gabinete a su casa m El acondicionador de aire no est debidamente nivelado El acondicionador de aire debe inclinarse ligeramente hacia abajo hacia el exterior Nivele el acondicionador de aire de manera que tenga una inclinaci n hacia abajo hacia el exterior para asegurar el debido desag e Vea instrucciones de instalaci n NOTA No perfore orificios en la parte inferior de la base de metal o del colector de condensado AYUDA O SERVICIO T CNICO Para evitar llamadas solicitando servicio innecesarias revise la secci n de Soluci n de problemas Podr a ahorrarle el costo de una llamada solicitando servicio Si a n necesita ayuda siga las siguientes instrucciones Si necesita ayuda o servicio t cnico Llame a nuestro centro de servicio autorizado a
6. The Exhaust control will function only when the Fan Control is operating Style 1 Cool only air conditioner settings Fan Control Set the Fan control to the desired setting When the air conditioner is operating at Low Cool High Cool or Turbo Cool the fan circulates air continuously m Turbo Cool for maximum cooling m High Cool for normal cooling m Low Cool for sleeping comfort m Fan Only to move air continuously without cooling NOTE Fan runs on Turbo speed only 10 Thermostat Turn the THERMOSTAT control to a mid setting Adjust the air conditioner s performance by turning the Thermostat control clockwise for maximum cooling For less cooling turn the THERMOSTAT control counterclockwise Experiment to find the setting that suits you best Style 2 Heat Cool Air Conditioner Settings on some models Fan Control Set the Fan control to the desired setting When the air conditioner is operating at Low Cool High Cool Turbo Cool Low Heat or Turbo Heat the fan circulates air continuously m Low Heat for reduced heating Turbo Heat for maximum heating Turbo Cool for maximum cooling High Cool for normal cooling Low Cool for sleeping comfort Fan Only to move air continuously without cooling or heating NOTE Fan runs on Turbo speed only m Power Saver the fan runs only when cooling is needed The fan stops circulating air when the room temperature matches the Thermostat control settin
7. mbolo de advertencia de seguridad Este s mbolo le llama la atenci n sobre peligros potenciales que pueden ocasionar la muerte o una lesi n a usted y a los dem s Todos los mensajes de seguridad ir n a continuaci n del s mbolo de advertencia de seguridad y de la palabra PELIGRO o ADVERTENCIA Estas palabras significan 4h PE L l G RO Si no sigue las instrucciones de inmediato usted puede morir o sufrir una lesi n grave Si no sigue las instrucciones usted pued i AADVERTENCIA seors ustea puede mori Todos los mensajes de seguridad le dir n el peligro potencial le dir n c mo reducir las posibilidades de sufrir una lesi n y lo que puede suceder si no se siguen las instrucciones INSTRUCCIONES IMPORTANTES DE SEGURIDAD ADVERTENCIA Para reducir el riesgo de incendio choque el ctrico o lesiones personales al usar su acondicionador de aire siga estas precauciones b sicas Conecte a un contacto de pared de conexi n a tierra de m No use un cable el ctrico de extensi n 3 terminales o m Desconecte el acondicionador de aire antes de No quite el terminal de conexi n a tierra darle servicio No use un adaptador m Use dos 0 mas personas para mover e instalar el acondicionador de aire CONSERVE ESTAS INSTRUCCIONES REQUISITOS DE INSTALACION Instalaci n a trav s de la pared Adem s de las herramientas enlistadas arriba se necesitan las siguientes herramientas para la instalaci n a trav s de la pa
8. s le convenga COLDER 23 Estilo 2 Adjustes de calefacci n del acondicionador de aire caliente fr a en algunos modelos Control de Fan Ventilaci n Ponga el control de FAN Ventilaci n en la posici n que desee Cuando el acondicionador de aire est funcionando a Low Cool Poco fr a High Cool Muy fr a Turbo Cool M ximo nivel de frio Low Heat Calor bajo o Turbo Heat Calor turbo el ventilador hace circular el aire continuamente Low Heat para reducir el nivel de calefacci n Turbo Heat para un maximo nivel de calefacci n Turbo Cool para enfriamiento m ximo High Cool para enfriamiento normal Low Cool para dormir c modo Fan Only para que el aire circule continuamente sin enfriarse NOTA El ventilador funciona en velocidad Turbo solamente m Power Saver Ahorro de energ a el ventilador funciona nicamente cuando se necesita enfriamiento El ventilador deja de hacer circular el aire cuando la temperatura de la sala es igual a la posici n del Control de Thermostat Termostato Debido a que el ventilador no hace circular continuamente el aire de la sala se consume menos energ a pero el aire de la sala circula con menos frecuencia Utilice el modo de Power Saver cuando est fuera del hogar o durmiendo NOTA El ventilador funciona en velocidad Low solamente Thermostat Termostato Gire el control de THERMOSTAT Termostato a un ajuste medio Ajuste el funcionamie
9. Width 22 57 5 cm plus twice the thickness of wood used to build frame A 16 40 6 cm 2xC B 22 57 5 cm 2xC A WARNING E Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock Ground wire must be connected to ground screw located in lower right corner of air conditioner when air conditioner is in cabinet The electrical ratings for your air conditioner are listed on the model and serial number label The model and serial number label is located behind the front panel on the front flange above the coil area Specific electrical requirements are listed in the chart below Follow the requirements for the type of plug on the power supply cord Power supply cord plug outlet Wiring requirements m 115 volt 103 5 min 126 5 max 0 m 0 12 amps 0 m 15 amp time delay fuse or circuit breaker m Use on single outlet circuit only 230 volt 207 min 253 max 230 208 volt 197 6 min Ya 0 6 te f Ki 253 max DOR T S 0 12 amps 15 amp time delay fuse or circuit breaker m Use on single outlet circuit only 230 volt 207 min 253 max m 230 208 volt 197 6 min E y 253 max SD S m 0 16 amps 20 amp time delay fuse or circuit breaker m Use on single o
10. estas instrucciones puede ocasionar la muerte incendio o choque el ctrico El alambre de puesta a tierra debe ser conectado a un tornillo de tierra ubicado en la esquina inferior derecha del acondicionador de aire cuando el acondicionador de aire est en el gabinete Las clasificaciones el ctricas para su acondicionador de aire est n enumeradas en la etiqueta de n mero del modelo y de serie La etiqueta de modelo y serie se encuentra detr s del panel delantero en la pesta a frontal sobre el rea del serpent n Los requisitos el ctricos espec ficos se indican en la tabla debajo Siga los requisitos para el tipo de enchufe en el cord n de alimentaci n el ctrica Tomacorriente para la clavija del cord n el ctrico Requisitos de cableado m 115 volts 103 5 m n 126 5 m x m 0 12 amperes 0 m Fusible de retardo de 15 amperes o disyuntor m Uselo solamente en un circuito con tornacorriente nico 16 Tomacorriente para la clavija del cord n el ctrico Requisitos de cableado y m 230 volts 207 m n 0 6 cm 253 m x l f m 230 208 volts 197 6 m n ES 253 max N Q 0 12 amperes Fusible de retardo de 15 amperes o disyuntor m Uselo solamente en un circuito con tornacorriente nico m 230 volts 207 min 253 m x of m 230 208 volts 197 6 min g 253 m x 0 16 amperes Fusible de retardo de 20 amperes o disyuntor m selo solamente en un circuito c
11. nuestro Centro de interacci n del cliente Llame gratis al 1 800 253 1301 en los EE UU Nuestros consultores est n disponibles para ayudarlo Cuando llame tenga a mano la fecha de compra y el n mero de modelo y de serie completos de su aparato Esta informaci n nos ayudar a atenderle mejor Nuestros consultores le proporcionan ayuda para m Caracter sticas y especificaciones para nuestra linea completa de aparatos electrodom sticos Informaci n sobre instalaci n Procedimientos de uso y mantenimiento Ventas de accesorios y refacciones Asistencia especializada al cliente asistencia en espa ol para personas con problemas auditivos problemas de la vista etc m Direcciones de vendedores compa as de servicio y distribuidores de refacciones en su localidad Nuestros t cnicos en servicio est n capacitados para satisfacer la garant a del producto y proporcionar servicios posteriores a la garant a en cualquier parte de los Estados Unidos Para localizar a una compa a de servicios autorizada en su rea puede buscar en las p ginas amarillas de su gu a telef nica Si necesita refacciones Si necesita pedir refacciones le recomendamos que utilice nicamente partes autorizadas por la f brica Estas partes se adaptar n y funcionar n correctamente porque han sido hechas siguiendo las mismas rigurosas especificaciones utilizadas para construir todos los nuevos aparatos electrodom sticos Para localizar
12. of your room air conditioner control to an active setting a f Room air conditioners are not designed to cool multiple m The local power has failed Wait for power to be restored rooms Air conditioner blows fuses or trips circuit breakers The filter is dirty or obstructed by debris Clean the filter The inside evaporator and outside condenser coils are dirty or obstructed by debris See Annual Maintenance m Too many appliances are being used on the same circuit Unplug or relocate appliances that share the same circuit There is excessive heat or moisture open container PERS a z cooking showers etc in the room Use a fan to exhaust a a arany heat or moisture from the room Ty noto use heat breaker of the correct capacity See Electrical producing appliances during the hottest part of the day Requirements The louvers are blocked Install the air conditioner in a location where the louvers are free from curtains blinds m An extension cord is being used Do not use an extension f furniture etc cord with this or any other appliance m You are trying to restart the air conditioner too soon after The outside temperature is below Gof te CIDO nottry to turning the Fan control off Wait at least 3 minutes after turning the Fan control off before trying to restart the air conditioner Air conditioner seems to run too much operate your air conditioner in the cooling mode when the outside temperature
13. L Poco fr a HIGH COOL Muy fr a o TURBO COOL M ximo nivel de fr o El acondicionador de aire no tiene el tama o adecuado para su habitaci n Verifique la capacidad de enfriamiento de su acondicionador de aire para habitaci n Los acondicionadores de aire para habitaciones no est n dise ados para enfriar varias habitaciones El filtro est sucio u obstruido por desechos Limpie el filtro 26 El evaporador interno y los serpentines del condensador externo est n sucios u obstruidos por desechos Vea Mantenimiento Anual Hay demasiado calor o humedad se est cocinando en recipientes abiertos duchas etc en la habitaci n Use un ventilador para eliminar el calor o la humedad de la habitaci n Trate de no usar aparatos que generan calor durante las horas m s calurosas del d a Las rejillas est n boqueadas Instale el acondicionador de aire en un lugar donde las rejillas no est n bloqueadas por cortinas persianas muebles etc La temperatura exterior es inferior a los 65 F 18 C No trate de poner en marcha el acondicionador de aire en el modo de enfriamiento cuando la temperatura exterior sea inferior a los 65 F 18 C La temperatura de la habitaci n que est tratando de enfriar est demasiado caliente Deje pasar m s tiempo para que el acondicionador de aire enfr e una habitaci n muy caliente Est n abiertas ventanas o puertas que dan al exterior Cierre todas las puertas y ventanas
14. This section tells you how to clean and care for your air conditioner properly Call your local authorized dealer for an annual checkup Remember the cost of this service call is your responsibility The air filter is removable for easy cleaning A clean filter helps remove dust lint and other particles from the air and is important for best cooling or heating and operating efficiency Check the filter every 2 weeks to see whether it needs cleaning NOTE Do not operate the air conditioner without the filter in place 1 Turn off air conditioner 2 Using the indents in top of filter door pull door down Filter door is not removable 3 Slide air filter up and out to remove from the filter door A A Indents B Filter Use a vacuum cleaner to clean air filter If air filter is very dirty wash it in warm water with a mild detergent Do not wash air filter in the dishwasher or use any chemical cleaners Air dry filter completely before replacing to ensure maximum efficiency 5 Slide air filter down into the filter door Close filter door 1 Unplug air conditioner or disconnect power 2 Remove the air filter and clean it separately See Cleaning the Air Filter 3 Wipe the front panel with a soft damp cloth 4 Air dry front panel completely 5 Plug in air conditioner or reconnect power Check once or twice a year for paint damage This is very import
15. alimentaci n el ctrica est desconectado Conecte a un contacto de pared de conexi n a tierra de 3 terminales Vea Requisitos el ctricos m Se ha fundido un fusible de la casa o disparado un disyuntor Reemplace el fusible o reposicione el disyuntor Conecte a un contacto de pared de conexi n a tierra de 3 terminales Vea Requisitos el ctricos m El control de Fan Ventilaci n se ha fijado en la posici n de apagado Fije el control de FAN en una posici n activa Se ha interrumpido la energ a el ctrica en su localidad Espere que se restablezca la energ a el ctrica El acondicionador de aire funde los fusibles o dispara los disyuntores m Se est n usando muchos aparatos en el mismo circuito Desconecte o ponga en otro lugar los aparatos que est n usando el mismo circuito m Se est usando un fusible de retardo o un disyuntor con la capacidad incorrecta Reempl celo con un fusible de retardo o un disyuntor con la capacidad correcta Vea Requisitos el ctricos 25 m Se est usando un cable el ctrico de extensi n No use un cable el ctrico de extensi n con este o cualquier otro aparato Usted est tratando de volver a poner en marcha el acondicionador de aire muy poco tiempo despu s de apagar el Fan Ventilaci n Espere por lo menos 3 minutos antes de poner en marcha el acondicionador de aire despu s de apagar el control de Fan Parece que el acondicionador de aire funciona excesi
16. ant especially in areas near oceans or where rust is a problem If needed touch up with a good grade enamel paint NOTE To reduce paint damage during the winter install a heavy duty cover over air conditioner cabinet For information on ordering a heavy duty cover see Accessories Your air conditioner needs annual maintenance to help ensure steady top performance throughout the year Call your local authorized dealer to schedule an annual checkup The expense of an annual inspection is your responsibility 11 TROUBLESHOOTING You can solve many common air conditioner problems easily saving you the cost of a service call Try the suggestions below to see whether you can solve your problem without outside help Air conditioner cycles on and off too much or does not cool heat room in cooling heating mode Air conditioner will not operate m The power supply cord is unplugged Plug into a grounded 3 prong outlet See Electrical Requirements The Fan control is set to POWER SAVER on some ae models Use Power Saver only when you are away from z ea pecs he Aa orbe PUG home or asleep since the fan does not circulate the room air into a grounded 3 prong outlet See Electrical continuously Use LOW COOL HIGH COOL or TURBO COOL Regui E for your best comfort equirements za The air conditioner is not properly sized for your room m The Fan control o tumeg tothe offiposition Tur aie TAN Check the cooling capabilities
17. ara las cortinas Extienda la cortina derecha hacia fuera de manera que pueda insertar el primer tornillo a trav s del orificio del medio de la cortina Utilice tornillos de cabeza de cono achatado 8 18 x para atornillar la cortina al orificio del medio en el gabinete del acondicionador de aire NOTA Se requiere este tornillo para ajustar correctamente la cortina de arriba hacia abajo al gabinete del acondicionador de aire E A Tornillo de cabeza de cono achatado 8 18 x 3 Con la cortina derecha todav a extendida inserte tornillos de cabeza de cono achatado 8 18 x en las ranuras superior y inferior de la cortina Atornille la cortina a los orificios superior y inferior en el gabinete del acondicionador de aire NOTA Algunas cortinas pueden tener dos ranuras en cada extremo Usted podr ver un orificio de montaje a trav s de la ranura correcta Deslice el alojamiento de la cortina en las gu as lo m s lejos posible Repita los pasos anteriores para la cortina izquierda Instalaci n a trav s de la pared NOTAS m Es responsabilidad y obligaci n del cliente hacer que este producto sea instalado por un t cnico calificado familiarizado con instalaciones a trav s de la pared de acondicionadores de aire de habitaciones m La parte de donde sale el cord n el ctrico del acondicionador de aire debe colocarse a no m s de 4 pies 122 cm de un tomacorrient
18. binet does not fall out of the opening during installation or removal The place where the power cord exits the air conditioner should be no more than 4 ft 122 cm from a grounded 3 prong outlet Do not block the louvers on the front panel Do not block the louvers on the outside of the air conditioner Window installation on some models Center empty cabinet in window Check that lower rail of air conditioner cabinet is behind and against back side of windowsill Maintain a firm hold on the air conditioner cabinet Lower window sash to hold cabinet in place Measure the distance between the right hand side of the cabinet and the inside of the window channel Repeat for the left side Adjust the cabinet until the distance on each side is the same bp J A B A Window sash B Empty cabinet C Window channel Check that air conditioner cabinet is tilted to the outside so that water will run to the outside Pull left hand curtain out until it fits into window channel Use a e drill bit to drill a starter hole through the hole in the curtain housing and into the lower window sash Front View a A Left hand curtain B Window channel Top View A Left hand curtain B Window channel C 8 x 34 round head screw 6 Insert one of the 8 x 34 round head screws through hole and into lower window sash Insert one of the 6 32 x 1 4 pan head screws through threaded hole in top of curtain 7 Repeat for ri
19. binete debe extenderse 1 2 13 mm dentro de la habitaci n Si hay un resguardo el gabinete debe extenderse 1 2 13 mm m s all del resguardo A 22 13 mm extendido dentro de la habitaci n B Resguardo 2 Use un nivel para verificar que el gabinete est nivelado de lado a lado a o 22 A Nivel Verifique que el gabinete del acondicionador de aire est inclinado hacia afuera para que el agua corra hacia afuera Vuelva a utilizar el aislamiento para sellar la abertura entre el gabinete y el marco Utilice los orificios existentes y 6 tornillos de madera de 8 x 12 no provistos para fijar el gabinete al marco NOTA No apriete demasiado los tornillos para que el gabinete no se deforme perjudicando el sellado del aire entre el gabinete y el acondicionador de aire P sele masilla a todas las aberturas exteriores de la pared alrededor del acondicionador de aire NOTA Trate el acondicionador de aire con cuidado Aseg rese de que el extremo libre del alambre a tierra est fuera del gabinete A ADVERTENCIA Peligro de Peso Excesivo Use dos o m s personas para mover e instalar el acondicionador de aire No seguir esta instrucci n puede ocasionar una lesi n en la espalda u otro tipo de lesiones Inserte el acondicionador de aire en el gabinete A ADVERTENCIA Peligro de Choque El ctrico Conecte el alambre verde de conexi n a tierra al tornillo de conexi n a tierra N
20. chufe el acondicionador de aire o desconecte el suministro de energ a 2 Quite el filtro de aire y limpielo por separado Vea Limpieza del filtro de aire 3 Limpie el panel delantero con un pa o suave y h medo Seque el panel delantero al aire completamente 5 Enchufe el acondicionador de aire o reconecte el suministro de energ a gt Revise una o dos veces al a o si hay da os en la pintura Esto es muy importante especialmente en lugares que est n cerca de los oc anos o donde la herrumbre es un problema Si es necesario retoque con un esmalte de buena calidad NOTA Para reducir el da o a la pintura durante el invierno instale una cubierta resistente sobre el gabinete del acondicionador de aire Para obtener informaci n sobre c mo pedir una cubierta resistente vea la secci n Accesorios Su acondicionador de aire necesita mantenimiento anual para ayudar a asegurar un rendimiento constante de la mejor calidad durante todo el a o Llame al vendedor autorizado de su localidad para hacer una cita para el chequeo anual El precio del chequeo anual es su responsabilidad SOLUCI N DE PROBLEMAS Usted puede resolver f cilmente muchos problemas frecuentes del acondicionador de aire ahorr ndose el costo de una llamada de servicio t cnico Pruebe las sugerencias que se incluyen a continuaci n para ver si puede resolver el problema sin ayuda Su acondicionador de aire no funciona m El cable de
21. e de conexi n a tierra de 3 terminales m No bloquee las rejillas Opci n 1 Moldura de madera metal o pl stico Cuando utilice una moldura de madera metal o pl stico el marco de madera debe estar alineado con la pared interior como se muestra Marco de madera Rejillas A Moldura B Pared interior CO Opci n 2 Pared enyesada sin moldura Si la pared enyesada va a nivelarse con el gabinete y no se utiliza ninguna moldura el marco de madera debe colocarse 1 2 13 mm dentro de la pared interior C Marco de madera A Pared enyesada B Pared interior D Rejillas Construya el marco de madera Vea Requisitos de ubicaci n para las dimensiones Mida el ancho y la altura exteriores del marco para determinar las dimensiones de la abertura de la pared Corte una abertura a trav s de la pared Quite y guarde el aislamiento NOTAS m Las dimensiones de la profundidad dependen del espesor de la pared y del tipo de moldura m No bloquee las rejillas que est n en el gabinete del acondicionador de aire m Utilice madera de 1 2 5 cm o m s pesada para el marco de madera A Ancho exterior B Altura exterior C Profundidad Aplique un sellador de madera a la superficie exterior expuesta Inserte el marco en la abertura en la pared Cuadre y nivele el marco Sujete con firmeza el marco a la pared Trat
22. e el acondicionador de aire con cuidado Aseg rese de que el gabinete del acondicionador de aire no se caiga de la abertura durante la instalaci n o al quitarlo La parte donde sale el cord n el ctrico del acondicionador de aire debe colocarse a no m s de 4 pies 122 cm de un tomacorriente de conexi n a tierra de 3 terminales No bloquee las rejillas que est n en el panel delatero No bloquee las rejillas que est n en el exterior del acondicionador de aire 19 Instalaci n en una ventana en algunos modelos 20 Centre el gabinete vac o en la ventana Verifique que el riel inferior del acondicionador de aire se encuentre detr s y contra la parte posterior del obturador de la ventana Sostenga con firmeza el gabinete del acondicionador de aire Baje el marco de la ventana para mantener el gabinete en su lugar Mida la distancia del lado derecho del gabinete a la parte interior del canal de la ventana Repita el procedimiento para el lado izquierdo Ajuste el gabinete hasta que la distancia a cada lado sea igual Le Ill A B A Marco de la ventana B Gabinete vacio C Canal de la ventana Verifique que el gabinete del acondicionador de aire est inclinado hacia afuera para que el agua corra hacia el exterior Tire de la cortina izquierda hacia afuera hasta que encaje en el canal de la ventana Utilice una broca de barrena de 9 para taladrar un primer orificio en el alojamiento de la cortina y dentro de
23. eal in the gap between air conditioner base and cabinet Push foam seal in at the sides and trim any excess i a material NOTE Handle air conditioner with care 1 Make sure the free end of the ground wire is outside of the cabinet 4 WARNING Excessive Weight Hazard Use two or more people to move and install air conditioner Failure to do so can result in back or other injury A Foam seal 2 Insert air conditioner into cabinet 5 Remove the 2 front panel screws from air conditioner base 6 Insert front tabs of front panel into top of cabinet and swing front into place A WAR IN l e 7 Attach bottom front of panel with front panel screws Replace control knobs on some models NOTE Route power supply cord through notch in front panel ZUM Electrical Shock Hazard Connect green ground wire to ground screw B Failure to do so can result in death or electrical shock 3 Connect green ground wire to cabinet base with ground A Front panel screws screw Position ground wire pointing straight up Put excess B Power supply cord notch ground wire between coil and air conditioner cabinet D A WARNING y Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord
24. elleno 27 1186897B O 2004 6 04 All rights reserved Printed in U S A Todos los derechos reservados Impreso en EE UU
25. g Since the fan does not circulate the room air continuously less energy is used but the room air is not circulated as often Use Power Saver when you are asleep or away from home NOTE Fan runs on Low speed only Thermostat Turn the THERMOSTAT control to a mid setting Adjust the air conditioner s performance by turning the Thermostat control clockwise for maximum cooling For less cooling turn the THERMOSTAT control counterclockwise Experiment to find the setting that suits you best For heating turn the THERMOSTAT control counterclockwise The electric strip heater is activated when the Fan control is set to a heat setting NOTE Your air conditioner is not designed to be used as a primary heat source It is intended for supplemental heating only Use the tabs to direct the air right or left on some models Rotate the whole cartridge to direct air up down or straight ahead When your air conditioner is operating normally you may hear sounds such as m Droplets of water hitting the condenser causing a pinging or clicking sound The water droplets help cool the condenser Air movement from the fan Clicks from the thermostat cycle Vibrations or noise due to poor wall or window construction A high pitched hum or pulsating noise caused by the modern high efficiency compressor cycling on and off AIR CONDITIONER CARE Your new air conditioner is designed to give you many years of dependable service
26. ght hand curtain A B C ast EA A Hole for 8 x 34 round head screw B Threaded hole C 6 32 x 14 pan head screw 8 Insert foam seal behind the top of the lower window sash and against the glass of the upper window 9 Place window lock bracket on top of lower window and against upper window sash 10 Use a 2 drill bit to drill a starter hole through the hole in the bracket and into the window sash 11 Attach window lock bracket to window sash with 8 x Y round head screw to secure window in place A Window lock bracket B Foam seal C Upper window glass Through the wall installation 1 Insert cabinet into the framed wall opening The top of the cabinet should extend Y 13 mm into the room If there is trim the cabinet should extend 1 2 13 mm past the trim AA i in i a Im i A 13 mm extending into room B Trim 2 Use a level to check that cabinet is level side to side 1 a o e2 A Level 3 Check that air conditioner cabinet is tilted to the outside so that water will run to the outside 4 Reuse the insulation to seal opening between cabinet and frame 5 Use existing holes and 6 8 x 12 wood screws not provided to attach cabinet to frame NOTE Do not overtighten screws or cabinet will distort and provide a poor air seal between cabinet and air conditioner 6 Caulk all outside wall openings around cabinet 4 Install foam s
27. ies 122 cm de donde el cable el ctrico sale del acondicionador de aire NOTA No use un cable el ctrico de extensi n m Libertad de movimiento del aire a las habitaciones que desea enfriar m Una abertura con la amplitud suficiente para el acondicionador de aire m Un soporte adecuado en la pared para el peso del acondicionador de aire El acondicionador de aire pesa entre 80 y 110 libras 36 3 a 49 9 kg NOTA No deben obstruirse las rejillas del gabinete El aire debe circular libremente a trav s de las rejillas del gabinete A N N NY S X A Rejillas del gabinete Instalaci n en la ventana en algunos modelos Medidas de la abertura de la ventana Ancho 28 71 1 cm m nimo a 40 101 6 cm m ximo Altura 16 41 3 cm m nimo A 28 71 1 cm m nimo a 40 101 6 cm m ximo B 16 4 41 3 cm m nimo Instalaci n a trav s de la pared Las medidas de la abertura en la pared deben ser Altura 16 40 6 cm m s el doble del espesor de la madera usada para construir el marco Ancho 22 57 5 cm m s el doble del espesor de la madera usada para construir el marco A 16 40 6 cm 2xC B 22 57 5 cm 2xC 15 A ADVERTENCIA y Peligro de Choque El ctrico Conecte a un contacto de pared de conexi n a tierra de 3 terminales No quite el terminal de conexi n a tierra No use un adaptador No use un cable el ctrico de extensi n No seguir
28. is below 65 F 18 C The temperature of the room you are trying to cool is extremely hot Allow extra time for the air conditioner to cool off a very hot room Windows or doors to the outside are open Close all m The current air conditioner replaced an older model The windows and doors use of more efficient components may cause the air conditioner to run longer than an older model but the total OE one sane a energy consumption will be less Newer air conditioners do heating not emit the blast of cold air you may be accustomed to from older units but this is not an indication of lesser cooling The Thermostat control is not at a cool enough setting capacity or efficiency Refer to the efficiency rating EER and Adjust the THERMOSTAT control to a cooler setting by capacity rating in BTU h marked on the air conditioner turning the knob clockwise Turn the FAN control to TURBO n e COOL m The air conditioner is in a heavily occupied room or heat 12 producing appliances are in use in the room Use exhaust vent fans while cooking or bathing and try not to use heat producing appliances during the hottest part of the day A higher capacity air conditioner may be required depending on the size of the room being cooled The air conditioner in the heating mode has insufficient BTUs hr for the heating requirements of the room Do not use the air conditioner as a primary source of heat Water drips from cabinet into
29. l marco inferior de la ventana Vista frontal A Cortina izquierda B Canal de la ventana 10 11 Vista superior A Cortina izquierda B Canal de la ventana C Tornillo de cabeza redonda 8 x 34 Inserte uno de los tornillos de cabeza redonda 8 x a trav s del orificio en el marco inferior de la ventana Inserte uno de los tornillos de cabeza de cono achatado 6 32 x 1 4 a trav s del orificio roscado en la parte superior de la cortina Repita el procedimiento para la cortina derecha A Orificio para tornillo de cabeza redonda 8 x 34 B Orificio roscado C Tornillo de cabeza de cono achatado 6 32 x 14 Inserte el obturador de espuma de la ventana detr s de la parte superior del marco de la ventana inferior y contra el cristal de la ventana superior Coloque el soporte de seguridad de la ventana en la parte superior de la ventana inferior y contra el marco de la ventana superior Utilice una broca de barrena de 22 para perforar un orificio para comenzar a trav s del orificio en el soporte y en el marco de la ventana Fije el soporte de seguridad de la ventana al marco de la ventana con un tornillo de cabeza redonda 8 x 3 4 para asegurar la ventana en su lugar A Soporte de seguridad de ventana B Obturador de espuma C Cristal de la ventana superior 1 Instalaci n a trav s de la pared Inserte el gabinete en la abertura de la pared con el marco La parte superior del ga
30. led or seriously injured if you don t follow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow these basic precautions m Plug into a grounded 3 prong outlet m Do not remove ground prong m Do not use an adapter m Do not use an extension cord m Unplug air conditioner before servicing m Use two or more people to move and install air conditioner SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS Assemble the required tools and parts before starting installation Read and follow the instructions provided with any tools listed here Tools Needed m Flat blade and Phillips screwdrivers m Tape measure m Drill and 2 or smaller bit m Level m Scissors Through the wall installation In addition to the tools listed above the following tools are needed for though the wall installation m Saw m 1 2 5 cm or heavier m Wood preservative lumber m Caulk m 8 x wood screws 6 Parts supplied on some models Check that all parts are included in parts package 2 iy E AA G A Foam seals 2 B Window lock bracket C 6 32 x Y pan head E 10 12 x pan head Phillips screws 3 F 8 18 x pan head Phillips
31. n also look in your telephone directory Yellow Pages If you need replacement parts If you need to order replacement parts we recommend that you only use factory authorized parts These parts will fit right and work right because they are made to the same exacting specifications used to build every new appliance To locate factory authorized parts in your area call our Customer Interaction Center telephone number your nearest authorized service center or Factory Service at 1 800 442 1111 in the U S A For further assistance If you need further assistance you can write to ask any questions or tell us about your concerns to Customer Interaction Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence Please record your model s information Whenever you call to request service on your appliance you need to know your complete model number and serial number You can find this information on the model and serial number label See Electrical Requirements for model and serial number location Please record the model and serial number information below Also record the purchase date of your appliance and the store s name address and telephone number Model Number Serial Number Purchase Date Store Name Store Address Store Phone Keep this book and the sales slip together for future reference You can order the following acces
32. ner installations m Where the power cord exits the air conditioner should be placed no more than 4 ft 122 cm from a grounded 3 prong outlet m Do not block louvers Option 1 Wood metal or plastic molding When using a wood metal or plastic molding the wood frame should line up with inside wall as shown A Curtain housing B Curtain guides ABC LIN A Molding C Wood frame B Inside wall D Louvers Option 2 Plaster wall with no molding If the plastered wall is to be flush with the cabinet and no molding is used the wood frame must be set Y 13 mm into the inside wall 4 5 6 A Plastered wall B Inside wall C Wood frame D Louvers Construct wood frame See Location Requirements for dimensions Measure outside width and height of frame to determine wall opening dimensions Cut opening through the wall Remove and save insulation NOTES m Dimension for depth depends on wall thickness and type of molding Do not block louvers in air conditioner cabinet m Use 1 2 5 cm or heavier lumber for wood frame A Outside width B Outside height C Depth Apply wood preservative to the outside exposed surface Insert the frame in the wall opening Square and level frame Attach frame securely to the wall Handle air conditioner with care Be sure your air conditioner ca
33. ng cabinet in window screw through the middle hole of the curtain Using 8 18 x 1 Locate supplied bag of screws pan head screw screw curtain to middle hole in air 2 Place top channel on top of air conditioner cabinet lining up conditioner cabinet the 3 holes in top channel with the 3 holes on top of air NOTE This screw is required to correctly attach curtain top conditioner cabinet to bottom to the air conditioner cabinet 3 Using 3 10 12 x 3 pan head Phillips screws attach top channel to air conditioner cabinet A 8 18 x pan head screw 6 While the right hand curtain is still extended insert 8 18 x pan head screws into the top and bottom slots of curtain Screw curtain to the top and bottom holes in air conditioner cabinet NOTE Some curtains may have 2 slots at each end You will A Top channel be able to see a mounting hole through the correct slot B 10 12 x pan head Phillips screws 7 S N Slide curtain housing into guides as far as it will go Repeat above steps for left hand curtain o 4 Insert top and then bottom of right hand curtain housing in top and bottom curtain guides on air conditioner cabinet Back View Through the wall installation NOTES m It is the customer s responsibility and obligation to have this product installed by a qualified technician familiar gt with through the wall room air conditio
34. nto del acondicionador de aire girando el control de Termostato hacia la derecha para un enfriamiento m ximo Para un menor enfriamiento gire el control de THERMOSTAT hacia la izquierda Experimente y busque el ajuste que m s le convenga 24 Para calentar gire el Control de THERMOSTAT Termostato hacia la izquierda El calentador de tira el ctrica se activa cuando el Control de Fan Ventilaci n se coloca en una posici n de calor NOTA Su acondicionador de aire no est dise ado para ser usado como fuente primaria de calor Est dise ado para ser una fuente suplementaria de calor solamente COLDER WARMER Use la leng etas para dirigir el aire hacia la derecha o hacia la izquierda en algunos modelos Gire el cartucho completo para dirigir el aire hacia arriba hacia abajo o directamente hacia adelante A Leng etas Cuando el acondicionador de aire est funcionando normalmente usted podr escuchar sonidos como m Gotas de agua que caen sobre el condensador produciendo tintineos o chasquidos Las gotas de agua ayudan a enfriar el condensador El movimiento del aire que sale del ventilador Chasquidos del ciclo del termostato Vibraciones o sonidos debidos a deficiencias en la construcci n de la pared o ventana m Un zumbido agudo o un sonido pulsante producido por la alternaci n de los ciclos del moderno compresor de alta eficiencia CUIDADO DE SU Hacer dorset tiie DE AIRE Su n
35. o seguir esta instrucci n puede ocasionar la muerte o choque el ctrico Conecte el alambre de puesta a tierra verde a la base del gabinete con el tornillo de puesta a tierra Coloque el alambre de puesta a tierra apuntando directamente hacia arriba Ponga lo que sobre del alambre de puesta a tierra entre el serpent n y el gabinete del acondicionador de aire W D A e gt B A Alambre verde de conexi n a tierra B Tornillo de puesta a tierra 21 4 22 Instale el obturador de espuma de la ventana en el espacio entre la base del acondicionador de aire y el gabinete Empuje el obturador en los costados y elimine cualquier exceso de material A Obturador de espuma Quite los dos tornillos del panel delantero de la base del acondicionador de aire Inserte las leng etas frontales del panel delantero en la parte superior del gabinete y oscile el frente para colocarlo en su lugar Fije el frente inferior del panel con los tornillos del panel delantero Vuelva a colocar las perillas de control en algunos modelos NOTA Haga pasar el cable de alimentaci n por la muesca en el panel delantero CLL YY YY A Tornillos del panel delantero B Muesca del cable de alimentaci n A ADVERTENCIA y Peligro de Choque El ctrico Conec
36. occccnidinnccinnccnncccnnnccnnncnnnnccnnnnncnnnnons 21 COMO USAR SU ACONDICIONADOR DE AIRE uccccucconcoosnnsss 23 C mo poner en marcha su acondicionador de aire 23 C mo cambiar la direcci n del aire ooonocncccnnncccnccinnccconcncnnnnon 24 Sonidos normales licita 24 CUIDADO DE SU ACONDICIONADOR DE AIRE 100000 25 Limpieza del filtro de aire ococnncccccnnccccnnnooononconrnnnnnnarnnonnanos 25 Limpieza del panel delantero oooooncccnncccnccnccccnnccanancncnncnonnccnnno 25 Reparaci n de la pintura da ada cccnoccccnonocccononocnnonnnnancnnnnanos 25 Mantenimiento anual ocococcconnccinccccnnccnonnccononnnonc cnn cnnnn cn nnncnnnncnnnns 25 SOLUCI N DE PROBLEMAS ccccoccocnsnonnonionisnonionincan canas ranceionioness 25 AYUDA O SERVICIO T CNICO ccuccucconionisnisionionionincaniocancascancaness 27 ACCESO OS moriria na 27 AIR CONDITIONER SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean ADANGER A WARNING You can be killed or seriously injured if you don t immediately follow instructions You can be kil
37. on tornacorriente nico M todo recomendado para la puesta a tierra Para su seguridad personal este acondicionador de aire debe ser puesto a tierra Este acondicionador de aire est equipado con un cable de suministro de energ a provisto de un enchufe con tres terminales Para reducir a un m nimo el peligro de posibles choques el ctricos el cable debe ser enchufado en un contacto apropiado de pared de tres terminales conectado a tierra de acuerdo con todos los c digos y reglamentos locales Si no se dispone de un tomacorriente apropiado es responsabilidad del cliente hacer instalar un contacto con tres terminales debidamente puesto a tierra por un instalador el ctrico calificado Es responsabilidad del cliente m Llamar a un instalador el ctrico calificado m Asegurarse de que la instalaci n el ctrica sea adecuada y est hecha de acuerdo con el C digo Nacional El ctrico ANSI NFPA 70 ltima edici n y todos los c digos y reglamentos locales Pueden obtenerse copias de las normas se aladas en National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 INSTRUCCIONES PE INSTALACION Quite el tornillo de puesta a tierra y el alambre de puesta a tierra del frente de la base del acondicionador de aire Guarde el tornillo de puesta a tierra
38. onador de aire no se caiga de la abertura durante la instalaci n o al quitarlo 3 Quite las perillas del control en algunos modelos m La parte de donde sale el cord n el ctrico del 4 Quite el panel delantero del acondicionador de aire y acondicionador de aire debe colocarse a no m s de 4 pies ap rtelo 122 cm de un tomacorriente de conexi n a tierra de 3 terminales 17 Instalaci n en una ventana en algunos modelos NOTA Sujete el canal superior y las cortinas laterales al gabinete del acondicionador de aire antes de colocar el gabinete en la ventana 1 2 4 18 Ubique la bolsa provista con tornillos Coloque el canal superior en la parte superior del gabinete del acondicionador de aire alineando los 3 orificios en el canal superior con los 3 orificios en la parte superior del gabinete del acondicionador de aire Utilice 3 tornillos Phillips de cabeza de cono achatado 10 12 x para fijar el canal superior al gabinete del acondicionador de aire VILL YUMA A Canal superior B Tornillos Phillips de cabeza de cono achatado 10 12 x 3 Inserte la parte superior y luego la parte inferior del alojamiento de la cortina derecha en las guias superior e inferior para cortinas en el gabinete del acondicionador de aire Vista posterior A Alojamiento de la cortina B Gu as para las cortinas Vista inferior A Alojamiento de la cortina B Gu as p
39. oner eeeeeseeseeseeeeeeeeeeeteeeeeneeeneeeees 10 Changing Air Direction es eeeeesceeseeeeeeeeeeeeneeseeeeeeeneeeaeeeneeaes 11 Normal SOU ii eis Seen ee ey 11 AIR CONDITIONER CARE 2 csseeceseeesseeesseeeeeneessneeseeeeeseeensoes 11 Cleaning the Air Filter cecccsceseeesceseseeeeeseeseseseeesneseeasenenscens 11 Cleaning the Front PaNel oococccccnnccnnconocanoncnnnnrncnnnnnrncnnnnarnrnnnnnno 11 Repairing Paint Damage ccoococonccccocccinoccnonoccnncnnoncncnnoncnncnnnnncnnnns 11 Annual Maintenance c ccceecceeceeeeeeeeeeeeeeeeeeceeeeeeneeeeeeeeeneeeaes 11 TROUBLESHOOTING fri wise soccesce ce chee ceasecsncdencececceceeccndesectestececasd 12 ASSISTANCE OR SERVICE cccsecesseeesseeeseneeesseeeseeeesneeesseeenees 13 ACCESS ir ane ees 13 INDICE SEGURIDAD DEL ACONDICIONADOR DE AIRE 2 00 14 REQUISITOS DE INSTALACI N ccnccoccansnsnaconionioninconiscescescenione 14 Herramientas y Pi Zas ccooocccccccconcccconcnonnccnnncnnancnnnncannncnnnnennnncnnnns 14 Requisitos de UbiCAaci n ccoccccnnncocccnonocnnonononnnnnnonnnnoncanenoncnnnnna 15 Requisitos el ctricOS cc aran aaah Eat eaaa iran nnaddd 16 INSTRUCCIONES DE INSTALACI N cccocoonacononanincenionisciscanione 17 DESOMPAQUE inicio dia 17 Installaci n del acondicionador de aire ooocooccccccinoccccncccnonnonnss 17 Colocaci n del gabinete del acondicionador de aire 19 Complete la instalaci n oooc
40. partes autorizadas por la f brica en su localidad llame a nuestro Centro de interacci n del cliente a su centro de servicio autorizado m s cercano o al Servicio de F brica al 1 800 442 1111 en los EE UU Para asistencia adicional Si necesita asistencia adicional puede escribir para hacernos cualquier pregunta o comunicarnos sus problemas a Customer Interaction Center 553 Benson Road Benton Harbor MI 49022 2692 EE UU Por favor incluya en su correspondencia un numero de tel fono en el que se le pueda localizar durante el dia Por favor anote la informaci n sobre su modelo Siempre que llame para solicitar servicio del aparato necesitar saber el n mero del modelo y el n mero de serie completos Esta informaci n la encuentra en la placa de n mero del modelo y n mero de serie Vea la ubicaci n del n mero del modelo y del n mero de serie en Requisitos el ctricos Por favor anote la informaci n sobre el n mero del modelo y el n mero de serie que se incluye abajo Anote tambi n la fecha de compra del aparato as como el nombre la direcci n y el tel fono de la tienda N mero del modelo N mero de serie Fecha de compra Nombre de la tienda Direcci n de la tienda _ Tel fono de la tienda Guarde este manual y la nota de compra juntos para referencia futura Usted puede ordenar los siguientes accesorios para su acondicionador de aire en el distribuidor autorizado de s
41. red Ensamble las piezas y herramientas necesarias antes de iniciar la instalaci n Lea y siga las instrucciones suministradas con m Sierra m Madera de 1 2 5 cm o cualquiera de las herramientas aqui enlistadas a Sellador de la madera m s pesada Herramientas necesarias Masilla m M para madera 8 m Destornilladores Phillipsy m Cinta para medir qe hojaplana m Taladro y una broca de Nivel 22 o m s peque a Tijeras 14 Piezas suministradas en algunos modelos Verifique que est n todas las piezas en el paquete de piezas a uty E E G A Obturadores de espuma 2 E Tornillos de cabeza de cono B Soporte de seguridad para achatado Phillips 10 12 x la ventana 3 3 C Tornillos de cabeza F Tornillos de cabeza de cono redonda 6 32 x 14 2 achatado Phillips 8 18 x 36 6 D Tornillos de cabeza G Canal superior redonda 8 x 34 3 H Cortinas laterales 2 NOTA Se incluyen piezas de instalaci n para ventanas de guillotina de hasta 40 101 6 cm de ancho Un Juego para Ventana Ancha especial est disponible de su distribuidor o centro de servicio Vea Accesorios IMPORTANTE Observe todos los c digos y reglamentos aplicables Verifique el lugar donde se instalar el acondicionador de aire La instalaci n correcta es su responsabilidad Aseg rese de que usted tenga todo lo necesario para una instalaci n correcta El lugar debe tener m Tomacorriente puesto a tierra a no m s de 4 p
42. rs to remove tape or glue These products can damage the surface of your air conditioner Handle air conditioner with care Remove air conditioner from carton and place on cardboard Remove shipping screw from side wall of cabinet ASA LLM o A Shipping screw Pull control knobs off on some models 4 Remove front panel from air conditioner and set aside 5 Remove ground screw and ground wire from front of air conditioner base Save ground screw e v B A Green ground wire B Ground screw 6 Pull on handle to slide air conditioner out of cabinet Place air conditioner on cardboard A Handle NOTE Do not lift push pull or remove any expanded polystyrene foam from inside the air conditioner It is not packing material Bottom View Be sure your air conditioner cabinet does not fall out of the opening during installation or removal WI m Where the power cord exits the air conditioner should be A Ss Handle air conditioner with care placed no more than 4 ft 122 cm from a grounded 3 prong outlet B z E A Curtain housing Window installation on some models B Curtain guides NOTE Attach top channel and side curtains to air conditioner 5 Extend right hand curtain outward so you may insert the first cabinet before placi
43. sories for your air conditioner from your local authorized dealer or by calling 1 800 253 1301 from anywhere in the U S A You will hear a recording Follow the instructions to place an order Replacement air filters A good clean air filter is important for best cooling with least energy consumption Your air filter should be cleaned regularly See Cleaning the Air Filter section for cleaning instructions We suggest you replace your air filter once a year Heavy duty cover If you decide to leave your air conditioner installed during the winter a heavy duty cover will help protect your air conditioner and reduce drafts The outdoor cover protects against cold drafts through the unit s air passages and protects the cabinet from snow rain sleet rust and dust For a heavy duty outdoor cover sized to fit your air conditioner order Part Number 484184 For a heavy duty indoor cover sized to fit your air conditioner order Part Number 4392940 Wide Window Kit A special Wide Window Kit is available for windows 40 101 6 cm to 54 137 2 cm wide Use Kit No 1162147 For models with side curtains curtains must be removed and replaced with filler boards 13 SEGURIDAD DEL ACONDICIONADOR DE AIRE Su seguridad y la seguridad de los dem s es muy importante Hemos incluido muchos mensajes importantes de seguridad en este manual y en su electrodom stico Lea y obedezca siempre todos los mensajes de seguridad Este es el s
44. t Termostato para su modelo Control de Respiradero en algunos modelos Coloque el control de Respiradero en la posici n CLOSED Cerrada para un enfriamiento m ximo continuo El control de Respiradero en la posici n OPEN Abierto hace escapar el aire afiejo humoso de la sala m OPEN para hacer salir el aire de la sala al exterior m CLOSED para que circule el aire en la sala CLOSED OPEN NOTA El control de Respiradero funciona nicamente cuando el control de Fan Ventilaci n est funcionando Estilo 1 Adjustes del acondicionador de aire s lo frio Control de Fan Ventilaci n Ponga el control de FAN Ventilaci n en la posici n que desee Cuando el acondicionador de aire est funcionando a Low Cool Poco fr a High Cool Muy fr a o Turbo Cool M ximo nivel de fr o el ventilador hace circular el aire continuamente m Turbo Cool para enfriamiento m ximo m High Cool para enfriamiento normal m Low Cool para dormir c modo E Fan Only para que el aire circule continuamente sin enfriarse NOTA El ventilador funciona en velocidad Turbo solamente Thermostat Termostato Gire el control de THERMOSTAT Termostato a un ajuste medio Ajuste el funcionamiento del acondicionador de aire girando el control de Termostato hacia la derecha para un enfriamiento m ximo Para un menor enfriamiento gire el control de THERMOSTAT hacia la izquierda Experimente y busque el ajuste que m
45. te a un contacto de pared de conexi n a tierra de 3 terminales No quite el terminal de conexi n a tierra No use un adaptador No use un cable el ctrico de extensi n No seguir estas instrucciones puede ocasionar la muerte incendio o choque el ctrico 8 Conecte a un contacto de pared de conexi n a tierra de 3 terminales C MO USAR SU ACONDICIONADOR DE AIRE Operar debidamente su acondicionador de aire le permite obtener los mejores resultados posibles Esta secci n le explica c mo operar su acondicionador de aire debidamente IMPORTANTE m Si usted apaga el acondicionador de aire espere por lo menos 3 minutos antes de volver a ponerlo en marcha Esto evitar que se queme un fusible del hogar o se dispare un disyuntor de circuito a causa del acondicionador de aire m Notrate de operar su acondicionador de aire en el modo de enfriamiento cuando la temperatura exterior sea menor de 65 F 18 C El serpent n interior del evaporador se congelar y el acondicionador de aire no funcionar debidamente NOTA En caso de corte de electricidad el acondicionador de aire funcionar con los ajustes previos cuando se reanude la electricidad 1 Coloque el control de respiradero Vea Control de Respiradero en algunos modelos 2 Ponga el control de ventilaci n en el ajuste deseado Vea Control de Fan Ventilaci n para su modelo 3 Gire el control de termostato a un ajuste medio Vea Thermosta
46. u localidad o llamando al 1 800 253 1301 desde cualquier lugar en los EE UU Escuchar una grabaci n Siga las instrucciones para hacer su pedido Filtros de aire de reemplazo Un filtro de aire limpio y de buena calidad es importante para obtener el mejor enfriamiento con el menor consumo de energ a Limpie regularmente el filtro de aire Vea las instrucciones de limpieza en la secci n Limpieza del filtro de aire Le recomendamos cambiar su filtro de aire una vez al a o Cubierta resistente Si usted decide dejar instalado su acondicionador de aire durante el invierno una cubierta resistente ayudar a proteger su aparato y reducir las corrientes de aire La cubierta para exteriores protege contra las corrientes de aire fr o a trav s de los orificios de paso de aire de la unidad y protege el gabinete contra la nieve la lluvia el agua nieve la oxidaci n y el polvo Para obtener una cubierta para exteriores resistente del tama o adecuado para su acondicionador de aire ordene la pieza 484184 Para obtener una cubierta para interiores resistente del tama o adecuado para su acondicionador de aire ordene la pieza 4392940 Un Juego para Ventana Ancha Un Juego para Ventana Ancha especial esta disponible de su distribuidor o centro de servicio para ventanas de 40 101 6 cm a 54 137 2 cm de ancho Use el Juego No 1162147 Para modelos con cortinas laterales debe quitar las cortinas y reemplazarlas por tablas de r
47. uevo acondicionador de aire esta dise ado para darle muchos a os de servicio confiable Esta secci n le ofrece la informaci n acerca de la limpieza adecuada y el cuidado de su acondicionador de aire Llame al vendedor autorizado de su localidad para un chequeo anual Acu rdese el precio de este servicio es su responsabilidad El filtro de aire se puede desmontar para facilitar su limpieza Un filtro limpio ayuda a quitar el polvo las pelusas y otras part culas del aire y es importante para que el aparato caliente opere y enfr e m s eficientemente Revise el filtro cada dos semanas para ver si necesita limpieza NOTA No haga funcionar el acondicionador de aire si el filtro no est colocado en su lugar 1 Apague el acondicionador de aire 2 Usando las muescas que est n en la parte superior de la puerta del filtro empuje la puerta hacia abajo La puerta del filtro no es desmontable 3 Deslice el filtro hacia arriba y hacia el exterior para sacarlo de la puerta del filtro A Muescas B Filtro Limpie el filtro usando una aspiradora Si est muy sucio lave el filtro con agua tibia y un detergente suave No lave el filtro de aire en la lavavajillas ni use limpiadores qu micos Seque bien el filtro al aire antes de colocarlo nuevamente para asegurarse la m xima eficiencia 5 Deslice el filtro hacia abajo en la puerta del filtro Cierre la puerta del filtro 1 Desen
48. utlet circuit only Recommended ground method For your personal safety this air conditioner must be grounded This air conditioner is equipped with a power supply cord having a grounded 3 prong plug To minimize possible shock hazard the cord must be plugged into a mating grounded 3 prong outlet grounded in accordance with all local codes and ordinances If a mating outlet is not available it is the customer s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrical installer It is the customer s responsibility m To contact a qualified electrical installer m To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances Copies of the standards listed may be obtained from National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 INSTALLATION PARA AWARNING Excessive Weight Hazard Use two or more people to move and install air conditioner Failure to do so can result in back or other injury Remove packaging materials Remove and properly dispose of packaging materials Remove tape and glue residue from surfaces before turning on the air conditioner Rub a small amount of liquid dish soap over the adhesive with your fingers Wipe with warm water and dry Do not use sharp instruments rubbing alcohol flammable fluids or abrasive cleane
49. vamente m Su actual acondicionador de aire reemplaz un modelo viejo El uso de componentes m s eficientes puede hacer que el acondicionador de aire funcione por m s tiempo que su antiguo modelo pero el consumo total de energ a ser menor Los acondicionadores de aire m s nuevos no emiten las r fagas de aire fr o a las que usted estaba acostumbrado con sus unidades anteriores pero esto no es indicio de menor capacidad o eficiencia en el enfriamiento Verifique el r gimen de eficiencia EER y el r gimen de capacidad en BTU h que se indican en el acondicionador de aire La unidad se encuentra en una habitaci n muy conges tionada o se est n usando en la misma habitaci n aparatos que generan calor Use ventiladores aspiradores cuando est cocinando o ba ndose y trate de no usar aparatos que generan calor durante las horas m s calurosas del d a Podr a necesitar un acondicionador de aire con m s capacidad dependiendo del tama o de la habitaci n que se desea enfriar El acondicionador de aire se enciende y se apaga demasiado o no enfria calienta la habitaci n en el modo de enfriamiento calefacci n m El control de Fan Ventilaci n est puesto en POWER SAVER Ahorro de energ a en algunos modelos Utilice el modo de ahorro de energ a nicamente cuando est fuera de su hogar o durmiendo debido a que el ventilador no hace circular el aire de la sala continuamente Para mayor comodidad use LOW COO
50. your house m The air conditioner is not properly leveled The air conditioner should slope slightly downward toward the outside Level the air conditioner to provide a downward slope toward the outside to ensure proper drainage See the Installation Instructions NOTE Do not drill a hole in the bottom of the metal base and condensate pan ASSISTANCE OR SERVICE To avoid unnecessary service calls please check the Troubleshooting section It may save you the cost of a service call If you still need help follow the instructions below If you need assistance or service Call the Customer Interaction Center telephone number Dial toll free 1 800 253 1301 Our consultants are available to assist you When calling Please know the purchase date and the complete model and serial number of your appliance This information will help us better respond to your request Our consultants provide assistance with m Features and specifications on our full line of appliances Installation information Use and maintenance procedures Accessory and repair parts sales Specialized customer assistance Spanish speaking hearing impaired limited vision etc m Referrals to local dealers service companies and repair parts distributors Our service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the authorized service company in your area you ca

Download Pdf Manuals

image

Related Search

Related Contents

Niveau avancé/ Deuxième cycle du secondaire Activité d  Turning Technologies Solutions Turning Technologies Solutions  important  Hifonics TSi600-II  Controller - E & S Technologies  取扱説明書等 - アイ・オー・データ機器  FXDP - User manual  Manuale del proprietario  Les enfants : À l`aube d`une anthropologie  Dell UP3214Q Monitor Statement of Volatility  