Omron Healthcare MC-505 User's Manual
Contents
1. A AS OMRON INSTRUCTION MANUAL Gezetle Temp H Model 505 i S i i i i I i i i i i i j i i D i i OMRON uas papel reciclado para ayudar a conservar nuestros recursos naturales Distribuido por OMRON HEALTHCARE INC 300 Lakeview Parkway Vernon Hills Illinois 60061 EE UU Copyright 1996 OMRON HEALTHCARE INC 1601401 4D i I e a O Display Messages 8 How To Take A Measurement 9 12 Care and Cleaning 18 Battery Replacement 14 Limited Three Year Warranty 15 E CAUTIONS This thermometer is designed to take a temperature through the ear canal DO NOT use it at any other site or tor any other purpose DO NOT force Safety Probe into the ear canal Keep Lens Covers out of reach of children DO NOT use the Gentle Temp Ear Thermometer in an infected ear DO NOT use a cellular phone in the same room when you are taking a temperature with the thermometer For accurate measurement DO NOT use the Gentle Temp Ear Thermometer without a Lens Cover Use this thermometer only with a new or cle
2. a few seconds the thermometer READY beeps and READY appears on the LCD panel 4 To change the MODE from oral to rectal or rectal to oral press the MODE button and hold for about one second The thermometer beeps when the MODE changes ORAL OA 5 To change from F to C or from C to F press and hold HOW TO TAKE A MEASUREMENT the MODE button then while stili holding the MODE button press and hold the ON SCAN button You will hear a beep signaling that degree MODE has been changed 6 Itis best to approach the ear from behind the person Carefully insert the Safety Probe into the ear canal until the body of the probe tip fully seals the ear canal 7 Do an ear tug Gently grasp the outer edge of the upper portion of the ear with your thumb and forefinger Gently but firmly pull the ear up and back as illustrated Continue pulling the ear until you have finished taking a temperature 1 0 7 i ES E i i H H i i MM 10 If you wish to take another 11 HOW TO TAKE A MEASUREMENT While holding the thermometer firmly in place press and release the ON SCAN button You will hear one short beep alerting you that the thermometer is working When the measurement is complete you will hear four beeps You may then gently remove the Safety Probe from the ear Read the m
3. 104 F 40 C Wait 30 minutes before retaking a temperature Make sure a Lens Cover is property attached Fully insert the thermo meter into the ear canal Retake the temperature Retum to Omron Healthcare Inc for repair Make sure battery is installed properly Retest If display shows battery low symbol or nothing at all immedi ately replace with new battery If you continue to have difficulty obtaining a reading call OMRON HEALTHCARE CUSTOMER SERVICE TOLL FREE 1 800 634 4350 Please tell the representative you have an Omron Model MC 505 Gentle Temp Ear Thermometer 8 HOW TO TAKE A MEASUREMENT OTE If there is any difference in the room temperature iere you store the thermometer and the room temperature where you take the measurement please let the thermometer sit in the measurement room at least 30 1 Remove the protective storage cap 2 Make sure that a clean Lens Cover is placed on the Safety Probe If the Lens Cover is dirty or missing attach a clean Lens Cover to the Safety Probe Tip by placing your thumb and forefinger on the collar of the Lens Cover and gently pushing it down Do not touch the plastic film of the Lens Cover A dirty or damaged Lens Cover may cause an inaccurate reading Push the Lens Cover down around the Safety Probe until it snaps into place 3 Press and release the ON SCAN button The LCD panel shows the Full Display for two seconds After
4. Keep Clean and Protected Use a soft dry cloth to clean the body of the thermometer Never clean the thermometer with an abrasive cleanser thinner benzene or submerge the thermometer in water or other liquids Do not expose the thermometer to extreme tem ares humidity direct sunlight or shock Store in a clean dry place at room temperature 13 BATTERY REPLACEMENT The Gentle Temp Ear Thermometer includes 3V lithium battery already installed Approximate battery life is three years If the Low Battery Indication symbol displays on the thermometer s LCD panel or the thermometer does not function at all immediately reptace the battery as follows Unscrew the Battery Cover and lift it off the body Remove the battery and replace it with a fresh one CR2032 type Place new battery with positive side Up replace cover and tighten screw After the battery is installed the MODE is in Oral and F CAUTION ONLY REPLACE BATTERY WITH TYPE CR2032 USE OF OTHER TYPES OF BATTERIES MAY PRESENT A RISK OF FIRE OR EXPLOSION SEE BELOW FOR SAFETY INSTRUCTIONS CAUTION BATTERY MAY EXPLODE IF MISTREATED DO NOT RECHARGE DISAS SEMBLE HEAT ABOVE 100 C 212 F OR INCINERATE KEEP BATTERY OUT OF REACH OF CHILDREN AMECA OON SERRA TE ne TT NARA testet cta bun IH Ciis reed IS ber MAA c uu LIMITED THREE YEAR WARRANTY Your MC 505 Gentle Temp Ear Thermometer is warranted to be free
5. Lens Covers MC 505LC are available from your Omron retailer The replacement box contains forty Lens Covers Use only OMRON MC 505LC Lens Covers with the MC 505 Using other Lens Covers may cause an inaccurate reading 12 Keep Clean and Protected CARE AND CLEANING y Probe Lens To ensure accurate measurements ex keep the Safety Probe Lens clean and free of scratches Fingerprints ear wax or dirt will impede the accu racy of the thermometer The Safety Probe Lens may be gently cleaned with a soft cotton cloth moistened with alcohol Do not use a paper towel The fibers in the paper towel will scratch the Safety Probe Lens Allow forty five minutes for the Safety Probe Lens to dry completely before attaching the Protective Storage Cap Always attach a clean Lens Cover and the Protective Storage Cap to the thermome ter when not in use If you see tears holes or scratches in the the Probe Lens you should return the thermometer to Omron Healthcare for repair Lens Cover To Change or Clean Change or clean the Lens Cover after each use Clean the Lens Cover when it is attached to the thermometer by using a soft cloth moistened with alcohol Do not use thinner or bezene Dry completely with a soft cloth before reusing If you see tears holes scratches or discoloration in the Lens Cover replace it Always use a Lens Cover when taking a measurement Always change or clean Lens Covers after each use Thermometer
6. el ULLA i 5 42 wee enciende el term metro termometro en la habitaci n donde toma la medid por Indicaci n Re parses canda el Coloque el term metro unos 30 minutos por le menos READY 2 eg term metro est listo dentro del canal del o do e para tomar mediciones e inicie la medici n 1 Quite la tapa protectora icaci 2 Verifique que haya una cubierta dicaciones Aparecen luego de pulsar el Coloque el term metro en un lim sh d a te abe da sobre la sonda bot n ON SCAN si la temper cuarto cuya temperatura se p 5 atura propia del term metro halle dentro de los l mites indi de seguridad Si la cubierta de lente no se encuentra dentro de los cados de 50 F 10 C a 104 F est sucia o no est colocada inserte una l mites de operaci n de 50 F 40 C Espere 30 minutos antes cubierta limpia sobre la cabeza de la sonda 10 C a 104 F 40 C de volver a efectuar una medici n de seguridad colocando su pulgar e ndice Aparece luego de pulsar Verifique que la cubierta sobr e el collar de la cubierta de lente y el bot n ON SCAN sila de lente est debidamente empujando suavemente hacia abajo No temperatura medida no se colocada Inserte el toque la pel cula pl stica de la cubierta de 97 encuentra dentro de los term metro por completo lente Una cubierta de lente sucia o da ada Ud l mites de temperatura en el canal del o do de duci t Chae humana de 95 F 35
7. lente OMRON MC 505LC con el term metro modelo MC 505 Si se utilizan cubiertas distintas es posible que las mediciones no sean exactas 12 CUIDADO Y LIMPIEZA Lente de la sonda de seguridad mant ngala limpia y protegida Para garantizar mediciones exactas mantenga siempre limpia la lente de la sonda de seguridad y evite marcas o rasgu os Las impresiones digitales cera del o do o suciedad afectar n la exactitud del term metro El lente de la sonda de seguridad se puede limpiar suavemente con un algod n humedecido en alcohol No utilice una toalla de papel Las fibras de la misma rayar n el lente Deje pasar por lo menos 45 minutos antes de colocar la tapa protectora para permitir que el lente se seque por comple 19 Cuando el term metro no se est utilizando mantenga siempre la cubierta del lente y la tapa de seguridad colo cadas Si observa roturas agujeros o rasgufios en el lente env e el term metro a Omron Healthcare para ser reparado Cubierta de lente c mo cambiar o limpiar Cambie o limpie la cubierta del lente luego de cada uso Cuando la cubierta est colocada en el term metro se la puede limpiar con un pa o suave humedecido con alcohol No utilice nunca solvente o benceno Seque por completo con un pa o suave antes de volver a utilizar Si observa roturas agujeros rasgu os o decoloraci n en la cubierta del lente reempl cela Cuando efect a una medici n aseg rese de que la cubi
8. sin soltar manteniendo siempre el term metro ro Ed el bot n ON SCAN Oir un tono breve cuando el en posici n Oir un tono breve que term metro haya cambiado de unidades de medici n indica que el term metro est fun ORAL cionando 6 Se recomienda aproxi 9 Cuando el term metro haya comple marse al o do por detr s tado la medici n emitir cuatro de la persona Inserte tonos breves Puede ahora retirar cuidadosamente la sonda la sonda de seguridad del o do Lea el valor medido en la pantalla del term metro de seguridad en el canal del o do hasta que quede sellado por el cuerpo de fa sonda 10 Si desea efectuar otra medici n espere unos diez segundos EI ter m metro emitir dos tonos breves y mostrar el mensaje READY en la pantalla Ya se ha efectuado la medici n Para mayor informaci n vea el p rrafo MEDICIONES REPETIDAS en la p gina 12 7 D un tir n de orejas Tome suavemente el 1 4 O Mm borde externo del l bulo E superior de la oreja con su pulgar e ndice Extienda suavemente pero con firmeza la oreja hacia arriba y hacia atr s como lo indica la 7 figura Mant ngala exten dida hasta que terminado la medici n 710 11 11 Para proteger la lente de la sonda de seguridad deje la cubierta de lente colocada sobre el term metro luego de haber completado la medici n Coloque la tapa protectora sobre la cabeza de la sond
9. su t cnica y ganar confianza en las mediciones que tome cuando alg n miembro de la familia est enfermo Lea por favor este manual de instrucciones por com pleto antes de utilizar el term metro Gentle Este producto est destinado exclusivamente a uso dom stico Si tiene dudas sobre el significado de una medici n de temperatura espec fica consulte por favor con su m dico El term metro Gentle Temp incluye los siguientes componentes Term metro de o do Gentle Temp modelo MC 505 21 cubiertas de lente Funda de pa o para transporte Bater a tipo CR2032 instalada Manual de instrucciones Tarjeta de garant a INTRODUCCI N Lente de la sonda de seguridad Sonda de seguridad Pantalla de cristal l quido Cubierta del alojamiento de bater a Tapa protectora para almace namiento Bot n ON SCAN ENCENDIDO MEDICI N Funda de pa o 7 Selecci n de unidades FIG Bot n MODE MODO Selecci n ORAL RECTAL Cubierta de lente descartable MENSAJES DE PANTALLA PANTALLA ACCI N Nota Si hay alguna diferencia entre la temperatura de Pantalla completa Aparece durante 2 Espere a que aparezca la habitaci n donde guarda el termometro y la READY Neer fi 5 segundos cuando se el mensaje Ready habitaci n donde toma la medida por favor ponga
10. C Repita la medici n puede producir una lectura inexacta ORAL RECTAL a 107 6 F 42 C Coloque la cubierta de lente sobre la sonda y empuje hasta que quede enganchada Aparece si el term metro Env e el term metro a detecta un error en la Omron Healthcare Inc 3 Pulse el bot n ON SCAN y su lte secuencia de prueba para ser reparado lo Se encender la pantalla completa durante dos segundos Luego de epee La tensi n de la bater a Verifique que la bater a est Unos pocos segu ndos m s el debidamente colocada term metro emitir un to READY Vuelva a probar Si la pantalla no breve y mostrar el mensaje a vuelve a mostrar el simbolo READY en la pantalla de bater a baja ni siquiera ORAL se enciende reemplace la 4 Para pasar del modo oral a rectal bater a por otra nueva Si contin a teniendo dificultades para obtener una medici n llame al TEL FONO SIN CARGO DE LA L NEA DE ASISTENCIA DE OMRON HEALTHCARE 1 800 634 4350 Ind quele al representante de la L nea de Asistencia que posee un term metro de o do Omron Gentle Temp modelo MC 505 8 viceversa oprima el bot n MODE y mant ngalo oprimido durante aproximada mente un segundo El term metro emitir un tono breve cuando haya cambiado de modo C MO EFECTUAR UNA MEDICI N 5 Para pasar de F a C o de C a F oprima sin soltar 8 Pulse el bot n ON SCAN y su ltelo el bot n MODE y al mismo tiempo oprima
11. DE EXPLOTAR NUNCA LA RECARGUE DESARME CALIENTE POR ENCIMA DE 212 F 100 C O INCINERE MANTENGA LA BATER A LEJOS DEL ALCANCE DE NI OS 14 AN Nm n as eee GARANTIA LIMITADA POR TRES ANOS Omron garantiza por tres a os que el term metro de o do Gentle Temp MC 505 bajo condiciones normales de uso no presentar defectos de manufactura Esta garant a se extiende solamente al comprador inicial del equipo Si durante el per odo de garant a se hace necesario reparar el equipo env elo a Omron Healthcare Inc 300 Lakeview Parkway Vernon Hills IL 60061 Attn Service Dept junto con 5 00 por cargos de envio y seguro En toda correspondencia incluya el modelo de su equipo y su numero de tel fono A nuestra opci n repararemos y reemplazaremos sin cargo todas las partes necesarias para corregir el defecto de materiales o mano de obra La garant a mencionada es completa y exclusiva El garante niega expl citamente responsabilidad por da os incidentes especiales o consecuentes de cualquier natu raleza algunos estados no permiten la exclusi n o lim itaci n de da os incidentes o consecuentes de manera que es posible que la garant a precedente no se aplique a su caso Toda garant a impl cita indicada por ley se limitar en duraci n a los t rminos de esta garant a algunos estados no permiten imponer plazos de vigencia a las garant as impl citas de manera que es posible
12. It s faster safer and easier to use than an oral thermometer There s no worry of broken glass or mercury ingestion Measurements can even be taken while a child is sleeping For adults the Gentle Temp Ear Thermometer offers fast convenient accurate readings without the wait of a conventional thermometer Temperature From The Ear Clinical research has shown that the ear is an ideal site for taking body temperature The eardrum shares blood vessels with the hypothalamus the part of the brain that controls body temperature Therefore the ear is an accurate indicator of internal body core temperature An ear temperature unlike an oral temperature is unaffected by factors such as talking eating drinking and smoking 5 A A NA TA AA SESENTA TAREE EENE a aaa Pm mt TONADA MINH E E INTRODUCTION Gentle Temp Ear Thermometer is hospital tested and Safety Probe Lens meets the American Society for Testing and Materials 1 ASTM accuracy standards under normal operating conditions Practice Makes Perfect We recommend that you practice with the Gentle Temp i on yourself and family members when you are healthy This way you can improve your technique and feel more ON SCAN Button N confident of the measurements you take when a family Safety Probe member is ill Please read this instruction manual completely before Select using your Gentle Temp Ea
13. LC fabricadas para el term metro de o do Gentle Cuando no se est utilizando el term metro de o do Gentle Temp coloque siempre sobre el mismo una cubierta de lente limpia y la tapa protectora Luego de cada uso Reemplace o limpie la cubierta de lente luego de cada uso Para limpiar la cubierta d jela colocada sobre la sonda de seguridad y l mpiela con un pa o o algod n humedecido con alcohol isoprop lico al 70 o agua jabonosa Seque la cubierta de lente con un pa o suave Deje pasar cuarenta y cinco minu tos para que la cubierta se seque por completo antes de tomar otra medici n NUNCA golpee el term metro ni lo deje caer al piso NO desarme nunca el term metro INTRODUCCI N Muchas gracias por haber adquirido el term metro de o do Gentle Temp Este instrumento avanzado permite medir la temperatura en forma segura exacta y r pida a trav s del canal del o do C mo funciona El term metro de o do Gentle Temp utiliza un proceso de medici n en dos etapas Primero el term metro Gentle Temp mide la temperatura del calor infrarrojo emitido por el t mpano y los tejidos circundantes A continuaci n convierte dicha medici n en una temperatura rectal u oral equivalente El equipo Gentle Temp M le brinda la conve niencia de poder medir la temperatura en el o do convir ti ndola luego en una lectura oral o rectal equivalente como por ejemplo 98 6 F 6 99 6 F cuy
14. a Guarde el term metro en un lugar seco y a temperatura ambiente La cubierta de lente se puede volver a usar siempre que se conserve limpia e intacta Para limpiarla fr tela suavemente con un algod n mojado en alcohol iso prop lico o agua jabonosa Deje que la cubierta se seque por completo antes de volver a utilizarla 12 El term metro se apagar autom ticamente luego de aproximadamente un minuto C MO EFECTUAR UNA MEDICI N MEDICIONES REPETIDAS Entre medici n y medici n el term metro Gentle Temp efect a una prueba de verificaci n interna que tarda unos diez segundos Una vez completada emitir dos tonos breves y mostrar el mensaje READY en la pantalla Ello indica que est listo para efectuar otra medici n Para garantizar una medici n exacta cambie o limpie la cubierta de lente luego de cada uso Para cambiar la cubierta de lente extr igala empujando con el pulgar sobre el collar de pl stico Al hacerlo la cubierta se desengan char Coloque la cubierta nueva La temperatura del o do izquierdo y derecho pueden ser distintas Puede tomar la temperatura en el o do derecho o izquierdo pero utilice siempre el mismo o do o efect e un promedio de las lecturas tomadas en ambos o dos CUBIERTAS DE LENTE DE REPUESTO Su distribuidor de productos Omron dispone de cubiertas de lente de repuesto MC 505LC La caja de repuestos contiene 40 cubiertas Utilice solamente cubiertas de
15. an intact Lens Cover attached Use only Omron Lens Covers model MC 505LC made for the Gentle Temp Ear Thermometer Always attach a clean Lens Cover and the Protective Storage Cap to the Gentle Temp Ear Thermometer when not in use After each use Replace or clean the Lens Cover after every use clean leave the Lens Cover on the thermometer Safety Probe and wipe the Lens Cover with a cloth or cotton swab moistened with rubbing alcohol Isopropyl 70 or mild soap and water Dry the Lens Cover with a soft cloth Allow forty five minutes drying time before taking another temperature DO NOT subject the thermometer to shock or drop it on the floor DO NOT disassemble the thermometer 4 Thank you for purchasing the Gentle Temp Ear Thermometer This remarkable instrument offers safe accurate and quick temperature measurement from the ear canal INTRODUCTION How Does it Work The Gentle Temp Ear Thermometer uses a two step process to take a temperature First the Gentle Temp measures the temperature of the infrared heat given off by the eardrum and surrounding tissues Second it converts this temperature into an oral or rectal temperature The Gentle Temp offers you the convenience of taking a temperature in the ear and gives you an oral or rectal temperature such as 98 6 F or 99 6 F that you understand The Gentle Temp is less threatening to a child than a rec tal thermometer
16. easurement on the LCD panel measurement wait about ten seconds The thermometer will beep twice and then displays READY The measurement is taken See TAKING REPEATED MEASUREMENTS on page 12 for more information To protect the Safety Probe Lens leave the Lens Cover on the thermometer when the measurement is complete Place the Protective Storage Cap over the Safety Probe Tip Store the thermometer in a dry place at room temperature You may reuse the Lens Cover provided you clean it and it is intact To clean simply wipe with a cotton swab moistened with rubbing alcohol or mild soapy water Allow the Lens Cover to completely dry before using it again 12 The thermometer automatically powers off after about one minute A NES As AA A A NR STARS HOW TO TAKE A MEASUREMENT TAKING REPEATED MEASUREMENTS The Gentle Temp takes ten seconds between measure ments to run an internal accuracy check You can take another measurement when the thermometer beeps twice and displays READY To ensure an accurate measurement change or clean the Lens Cover after each use To change the Lens Cover push up with your thumb on the plastic collar The Lens Cover will pop off Attach a new Lens Cover The left and right ear temperature may differ You can take a temperature from either the left or right ear but use the same ear each time or an average of both REPLACEMENT LENS COVERS Replacement
17. erta de lente est siempre colocada Siempre cambie o limpie la cubierta del lente luego de cada uso Term metro mant ngalo limpio y protegido Limpie el cuerpo del term metro con un pa o seco y suave No limpie nunca el term metro con un limpiador abrasivo solvente o bencrno y nunca sumerja el term metro en agua u otros l quidos Nunca exponga el term metro a condiciones extremas de temperatura humedad o luz directa del sol Prot jalo contra golpes Gu rdelo en un lugar limpio y seco a temperatura ambiente 13 RECAMBIO DE BATER A El term metro de o do Gentle Temp se entrega con una bater a instalada de litio de 3 V La vida aproximada de la bater a es de tres a os Si aparece el s mbolo de bater a en la pantalla o el term metro no funciona reemplace la bater a inmediatamente siguiendo para ello las siguientes instrucciones Destornille y extraiga la cubierta de la bater a Extraiga la bater a y coloque una nueva tipo CR2032 El polo positivo de la bater a debe mirar hacia arriba Vuelva a colocar y enroscar la tapa Luego de reemplazar la bater a el term metro funcionar inicialmente en el modo oral y en F PRECAUCI N REEMPLACE NICAMENTE CON BATER A TIPO CR2032 SI SE UTILIZA OTRO TIPO DE BATER A SE CORRE EL RIESGO DE PROVOCAR UN INCENDIO O EXPLOSI N VEA LAS INSTRUCCIONES DE SEGURIDAD QUE SE INCLUYEN A CONTINUACI N PRECAUCI N SI SE LA MALTRATA LA BATER A PUE
18. from manufacturing defects for a period of three years under normal use This warranty extends only to the original retail purchaser Should repair be needed within the warranty period ship the unit prepaid to Omron Healthcare Inc 300 Lakeview Parkway Vernon Hills IL 60061 Attn Service Dept together with 5 00 for return Shipping and insurance Be sure to include the model number of your unit and your phone number on any correspondence We will either repair or replace at our option free of charge any parts necessary to correct defects in the materials or workmanship The above warranty is complete and exclusive The warrantor expressly disclaims liability for incidental Special or consequential damages of any nature Some States do not allow the exclusion or limitation of incidental or consequential damages so the above w rranty may not apply to you Any implied warranties arising by the operation of law shall be limited in duration to the term of this warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state FOR CUSTOMER SERVICE CALL TOLL FREE 1 800 634 4350 Omron uses recycled paper to help preserve our natural resources Distributed by OMRON HEALTHCARE INC 300 Lakeview Parkway Vernon Hills Illin
19. o valor se puede interpretar f cilmente El term metro Gentle Temp asusta menos a un ni o que un term metro rectal Es m s r pido seguro y f cil de usar que un term metro oral No hay que preocuparse por vidrios rotos o ingesti n de mercurio Se pueden tomar mediciones de temperatura mientras el ni o est durmien do Para los adultos el term metro de o do Gentle Temp ofrece lecturas exactas r pidas y convenientes sin la demora de un term metro convencional Temperatura del o do Las investigaciones cl nicas han demostrado que el o do es un rgano ideal para tomar la temperatura del cuerpo humano El t mpano comparte vasos sangu neos con el hipot lamo la parte del cerebro que controla la temperatu ra del cuerpo Por lo tanto el o do es un indicador exacto de la temperatura interna del cuerpo A diferencia de un term metro oral factores tales como hablar comer beber y fumar no afectan el funcionamiento de un term metro de o do 5 a El term metro de o do Gentle Temp ha sido probado en hospitales y cumple bajo condiciones normales de operaci n con las normas de exactitud de la Sociedad Americana para Prueba de Materiales ASTM La perfecci n viene con la pr ctica Recomendamos que practique con el term metro Gentle Temp tomando mediciones sobre s mismo y sobre miembros de su familia cuando se encuentren en buenas condiciones de salud De esa manera podr mejorar
20. ois 60061 Copyright 1996 OMRON HEALTHCARE INC 2 err le Temp TERM METRO DE O DO Ed ESPANOL PrECAUCION ES PE 4 Introducci ici 5 6 riesci eee a Passa suae d eo 6 Conozca su OQUiPO occccooccononcccconcccnonananonnnnncnnnaco nennen nnne 7 Mensajes de pantalla nn C mo efectuar una medici n 9 12 Cuidado y 13 Recambio de 14 Garant a limitada por tres 15 AAA PRECAUCIONES Este term metro est dise ado para tomar la temperatura a trav s del canal del o do NO lo aplique en ning n otro lugar ni lo utilice para otro prop sito NUNCA introduzca la sonda de seguridad por la fuerza en el canal del o do Mantenga las cubiertas de lente lejos del alcance de los ni os NUNCA utilice el term metro de o do Gentle Temp en un o do infectado NUNCA utilice un tel fono celular en el mismo cuarto en el que est tomando la temperatura Para obtener una medici n exacta NUNCA utilice el term metro de o do Gentle Temp sin una cubierta de lente Utilice el term metro s lo con una cubierta de lente intacta nueva o limpia colocada Utilice solamente cubiertas de lente Omron modelo MC 505
21. que la limitaci n mencionada no se aplique a su caso Esta garant a le otorga derechos legales espec ficos y otros m s que pueden variar de un estado a otro PARA OBTENER SERVICIO T CNICO S RVASE LLAMAR AL TEL FONO SIN CARGO 1 800 634 4350 15
22. r Thermometer This product is intended for household use only If you have questions about the meaning of a specific temperature please talk to your physician LCD Panel COMPONENTS Gentle Temp includes the following components MODE Button E ORAL RECTAL Select Gentle Temp Ear Thermometer Model MC 505 1 21 Lens Covers Battery i Soft Storage Case 3 Compartment Cover Battery Type CR2032 installed gt Instruction Manual Warranty Card Protective Soft Case Disposable 6 i Storage Cap 7 Lens Cover RR A Ta a ti DISPLAY Displays for 2 seconds when the thermometer is first turned on Ready Indication Displays when READY p y thermometer is ready for measurement Displays after ON SCAN button is pushed if the thermometer s own temperature is not within its operating range of 50 F 10 C to 104 F 40 C Displays after ON SCAN button is pushed if the temperature measure ment is not within the human temperature range of 95 F 35 C to 107 6 F 42 Displays if the thermometer senses an error in self check procedure Battery Indication r No Display Battery voltage is excessively low NDA iei P Uta acest ceat AM ACTION insert the thermometer Probe into the ear canal and begin measurement Put the thermometer in a room within the range of 50 F 10 C to
Download Pdf Manuals
Related Search
Related Contents
rant des complications toxico-muscu nistration d`une statine ou de Advantech AKMB-G41 User Manual 2210KL - scalenet.com ÉTAPE 1 : Connaître Celui en qui je crois ÉTAPE 2 : Me Evolve LFM-20 Philips Saeco RI9943 (取扱説明書より抜粋)pdf OVAL FAST SET™ POOL Haier LE32B50 User's Manual Copyright © All rights reserved.
Failed to retrieve file