1. CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Note The use of either multi mode or single mode fiber to operate at 100Mbps speed over long distances i e over approx 400 meters can be achieved only if the following factors are both applied e The 100Mb fiber segment must operate in full duplex FDX mode and e The worst case OPB of the fiber link must be greater than the fiber cable s passive Attenuation Attenuation Cable loss LED aging loss Insertion loss safety factor 3 8 6 Connections to NICs which support Auto Negotiation RJ 45 ports The copper ports of Magnum CS14 Sereis Converter Switches will function properly with NICs Network Interface Cards which support Auto Negotiation and the Fast Link Pulse FLP coding for the 1OOBASE TX signaling system When connecting a NIC to the CS14 Series it may be necessary to reload the NIC drivers on the user device if the NIC has been communicating with a protocol other than 1OOBASE TX such as 10BASE T When 100Mb operation is agreed and in use the 10 100 LED is illuminated steady ON and is OFF if 10 Mbps traffic www GarrettCom com 56 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 4 0 OPERATION 4 1 Dual Speed Functionality and Switching The Magnum CS14 and CSN14 Series Converter Switches provide four switched ports three ports in the front and one on the rear The architecture supports a du
2. ss 48 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 optional it connects to the CS14H chassis Ensure that each lead is securely tightened from the top as shown here NOTE Always use a voltmeter to measure the voltage of the incoming power supply and figure out the ve potential lead or ve potential lead The more ve potential lead will connect to the post labeled ve and the rest to the ve The GND can be hooked up at the last When power is applied the green PWR LED will illuminate 3 8 Connecting Ethernet Media The Magnum CS14 and CSN14 Series Converter Switch can be connected to two media types i e fiber and copper RJ 45 types runt at 1OOBASE TX LOBASE T and 100BASE FX or 1OBASE FL CAT 5 cables should be used when making 100BASE TX connections When the ports are used as 1OBASE T ports CAT 3 may be used In either case the maximum distance for unshielded twisted pair cabling is 100 meters 328 ft For Www GarrettCom com 49 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 fiber port IOBASE FL or 1OOBASE FX multi mode 50 125 or 62 5 125 microns cabling can be used whereas for single mode 9 125 microns cabling should be used Fiber cabling supports much longer cable distance and higher bandwidths as compared to copper wiring Media IEEE Standard Connector Twisted Pair CAT 3 or 5 10BASE T RJ 45 Twisted Pair CAT 5 100BASE TX RJ 45 Fi
3. 4 For Port 1 or 1SW if the LINK LED is not illuminated move the switch which has a cross over or up link for linking to another hub or Switch Www GarrettCom com 51 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 3 8 2 Connecting Fiber Optic ST type twist lock The following procedure applies to installations using ST type fiber connectors This procedure applies to ports using multi mode ST fiber connectors 1 Before connecting the fiber optic cable remove the protective dust caps from the tips of the fiber connectors Save these dust caps for future use 2 Wipe clean the ends of the dual connectors with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using color bands at regular intervals you must use the color coded strand on the associated ports at each end of the fiber optic segment 3 Connect the Transmit TX port light colored post on the Magnum Fiber port to the Receive RX port of the remote device Begin with the color coded strand of the cable for this first TX to RX connection 4 Connect the Receive RX port dark colored post to the Transmit TX port of the remote device Use the non color coded fiber strand for this 5 The LINK LED on the front of the fiber connector will illuminate when a proper connection has been established at both ends and wh
4. This section describes CS14 and CSN14 Series models including appearance features and typical applications 2 1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this product notify the carrier immediately of any damage which you believe occurred during shipment or delivery Inspect the contents of this package for any signs of damage and ensure that the items listed below are included This package should contain 1 Magnum CS14 or CSN14 Series Converter Switch unit 1 External Power Supply for d i Hd Hi Pd and Pi models only 1 set Metal panel mounting clips and screws 2 each 1 User Guide this manual Www GarrettCom com 14 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Remove the Magnum CS14 or CSN14 Series Converter Switch from the shipping container Be sure to keep the shipping container should you need to ship the unit at a later date In the event there are items missing or damaged contact your supplier If you need to return the unit use the original shipping container Refer to Section 5 Troubleshooting for specific return procedures 2 2 Product Description Combine a 10 or 100 Mb Fiber Media Converter and a two port 10 100 copper Switch and you have the Converter Switch a flexible edge of the network Ethernet product Add in fiber port choices for all multi mode and single mode fiber connector types plus AC or DC
5. ETSI compliant H and P models IEEE P1613 Env Std for Electric Power Substations P models NEMA TS 2 and TEES for traffic control equipment P models designed for UL 2043 above the ceiling installation IEC61850 EMC and Operating Conditions Class C Power Substations Warranty Three years return to factory Made in USA 10 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 1 2 Summary of models and descriptions Note The CSN14 model consists of the base unit type and the power input Insert S for sgl mode The CS14 model consists of the base unit type the fiber flavor ff and the power input CSN14 Models for 10Mb fiber CSN14 d or i two 10 100 RJ 45 one 10Mb ST Fiber port for office and wiring closet rated 0 to 40 C using an external AC power supply CSN14H Hd Hi Hardened H two RJ 45 one 10Mb Fiber port for factory floor rated 25 to 60 C using a direct DC 8 15VDC and or external AC hardened power supply included CSN14H 12VDC Same as CS14H model except AC hardened power supply is not included CSN14H 24VDC Same as CS14H 12VDC model except 24VDC power input replaces 12VDC CSN14HR 24VDC Same as CS14H 24VDC model but includes DIN RAIL MC2 mounting option CSN14H 48VDC Same as CS14H 24VDC model except 48VDC power input replaces 24VDC CSN14P Pd Pi Premium P two 10 100 RJ 45 one 10Mb Fiber port for un controlled outdoor rated 40 to 75 C using direct DC 8 15VDC an
6. H factory floor and premium P temperature un controlled location models have closed cases to withstand dirt and use special thermal techniques to transfer heat to the outside of the case for cooling www GarrettCom com 4 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 POWER SUPPLY These products are intended to be supplied by a Listed Direct Plug In power unit marked Class 2 or a Listed ITE Power Supply marked LPS which has suitably rated output voltage i e 9vdc 12vdc 24vdc 48vdc and suitably rated output current i e 100mA to 500mA When connected to a 48 V centralized dc source these products shall be provided with a Listed 5 A DC fuse in the supply circuit AC POWER SUPPLY using an external power adapter All models have an 8 15 VDC output with 6ft long cord and a 2 5mm center ve jack The power supplies are temperature rated to match the Converter Switch ratings Office Ratings 0 to 40 C North America d models Input direct plug in 95 125vac at 60 Hz Output 12vdc 1Amps www GarrettCom com 5 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 International i models Input 240vac at 50Hz with IEC 320 connector for the user supplied AC power cord Output 12vdc 1Amps Factory Floor H Ratings 25 to 60 C North America Hd models Hardened factory floor temperature rated Input 6ft AC power cord to IEC 320 connector on the 10
7. accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference ii CS14 CSN14 Series Converter Switch Installation and User Guide 02 06 Contacting GarrettCom Inc Please use the mailing address phone and fax numbers and email address listed below GarrettCom Inc 47823 Westinghouse Drive Fremont CA 94539 Phone 510 438 9071 Fax 510 438 9072 Website http www GarrettCom com Email support garrettcom com iii CS14 CSN14 Series Converter Switch Installation and User Guide 02 06 TABLE OF CONTENTS Page 1 0 SPECIFICATIONS scsscsssssssssssssssessssesnessesssecsssessecsssessessesesserseeess 1 1 1 Technical Specifications cssccsesesoessesesescnstsenencensoseserensnenveres 1 1 2 Summary of models and descriptions 0 0 0 eeeeeeeeeeeeeeeeeeeeneeeeeneees 11 2 0 INTRODUCTION sesesseseseroeseseeccoesoroesesesoeeosoroesesoecesosoeoesesoroeeeseeesoesose 14 2 1 Inspecting the Package and
8. auto cross MDIX They are shielded 8 pin female connectors for shielded STP and unshielded UTP Cat 3 4 5 cable One Fiber optic port On the CSN14 Series it is 1OBase FL with ST connections and on the CS14 series it is 100Base FX with a fiber flavor choice of multimode SC ST or MTRJ or single mode SSC SSCL SST or SLC connectors Switches Fiber Port 1 is controlled by an F H switch provided underneath it F enables full duplex mode and H enables half duplex mode The default setting is F for 100Mb fiber models H for 10Mb fiber models Www GarrettCom com 8 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 LED Indicators Dual front and top POWER Steady ON when power applied 10 100 Steady ON for 100Mbps OFF for 10 Mbps LK ACT Steady ON for LINK LK with no traffic BLINKING indicates port is transmitting receiving ACT F H Steady ON for full duplex OFF for half duplex Mounting options Metal mounting clips for panel mounting included DIN Rail mounting option Model DIN RAIL MC2 see Section 3 4 Rack mount option MC14 TRAY see http www garrettcom com mc_tray htm Mean Time Between Failure MTBF over15 years Telcordia Bellcore Method CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Agency Approvals and Standards Compliance UL Listed UL 60950 cUL CE Emissions meets FCC Part 15 Class A NEBS L3 and
9. input power selection and multiple application environments and you have the Magnum CS14 and CSN14 Converter Switch family The Magnum CS14 and CSN14 family of Converter Switches with a 100 Mb or 10Mb Fiber port built in covers the full range of application environments with regular office Hardened factory floor and Premium rated outdoor versions Extra features for Www GarrettCom com 15 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 heavy duty and extended temperature operation ranges are included selectively in the Hardened factory floor and Premium rated outdoor models This selection of models and fiber port types offers the best price to value ratio for each user and installation Where a Media Converter might have been used a Converter Switch offers a better value The compact package is ideal for network edge installations and is able to be conveniently mounted to suit any application The Magnum CS14 and CSN14 regular package units are for office and indoor wiring closet environments These are the economical base units in the CS14 and CSN14 Switch family An external AC power supply for either North America d 115vac 60Hz or international I 230vac 50Hz is included The ambient temperature rating is 0 C to 40 C office grade A robust metal case with convection cooling is featured Metal mounting clips are included and rack mount tray options are available Www GarrettCom co
10. or H 4 4 Dual LEDs Front panel and side panel Magnum CS14 and CSN14 LED Description PWR Illuminates GREEN to indicate power applied LK ACT Steady ON for LINK w no traffic blinking for activity per port LINK will turn off in the event connectivity is lost between the ends of the twisted pair segment or a loss of power occurs in the unit or remote device The Link ports are also represented by LAI LA2 LA3 Steady On or steady Off indicates no Receive Activity 10 100 Steady ON for 100Mb speed OFF for 1OMb speed per port F H Steady ON for Full duplex mode OFF for half duplex per port Www GarrettCom com 61 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 5 0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments The installation of Magnum CS14 and CSN14 Series 10 100 Mb s Switches is a straightforward procedure see INSTALLATION Section 3 0 the operation is also straightforward and is discussed in Section 4 Should problems develop during installation or operation this section is intended to help locate identify and correct these types of problems Please follow the suggestions listed below prior to contacting your supplier However if you are unsure of the procedures described in this section or if the Magnum CS14 and CSN14 Series 10 100 Mb s Switch is not performing as expected do not attempt t
11. software and the result of the auto negotiation is changed in the managed switch by the manager commands In such cases the 10 100 speed or the F H mode may be affected but auto cross in the CS14 Switches will still work The auto cross function cannot be disabled When an RJ 45 cable connection is made and each time LINK is enabled auto negotiation takes place except for legacy products which do not have auto negotiation and which go to the default state accordingly The Magnum Switch advertises its capability for 10 or 100 Mbps speed and F H duplex mode and the device at the other end of the cable should similarly advertise respond Both sides will agree to the speed and mode to be used per the IEEE 802 3u standard Depending upon the devices connected this will result in agreement to operate at either 10 Mbps or 100Mbps speed and full or half duplex mode 4 3 F H Switch Full Duplex or Half Duplex options for Fiber port 1 The F H manual switch has been provided for fiber port 1 for fixing that port at Full or Half Duplex as per the requirements The F H manual switch is being Www GarrettCom com 60 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 located underneath the fiber port The Fiber port with 10Mb is being set at Half Duplex and the 100Mb being set at Full Duplex as default from the factory The port can be set at the required mode by sliding the manual switch position to F
12. the Product c cescceseeeeceteeeeeeneeenes 14 2 2 PROGUCL Description 625 055 scssusesscssusectescveevidgsaas oss socsetsesousevesendersessocdeuns 15 2 3 Frame Buffering and Latency 0 eee ceeeecseeeeceeeeeeeaeeeeeseeneeseeneees 23 2A Features and Benefitsiessen tapane dan Sa 27 2 5 Applications for CS14 and CSN14 Series Converter Switches 30 3 0 INSTALLATION Qu ssssssssssssssrsessessssesscssssessessssesscssssessessnsessesessesers 38 3 1 Locating the Converter Switch Unit 0 eee eee cee esse cseeseeeseeenee 38 3 2 MC14 TRAY for Rack Mounting of CS14 Series Switches 40 3 3 MC14 TR PS9 and X2 for Rack Mounting Media Converters 41 3 4 DIN Rail mounting Option eee ee ceeeeeeeeeseceseceseseaeeeeeaee 43 3 5 Power Requirements CS14 and CSN14 Series Switches 44 3 6 Powering the CS14H CSN14H and CS14P CSN14P DC internal 46 wir GarrettComn com iv CS14 CSN14 Series Converter Switch Installation and User Guide 02 06 3 7 CS14H and P Series DC powered Installation 0 0 0 48 3 8 Connecting Ethernet Media 0 cece eceeeecseesecneeeeeeseeeeeaecaeeseeneeeeenes 49 3 8 1 Connecting Twisted Pair cee cseecseseceseneeeecsseeeeesecaseseeneees 51 3 8 2 Connecting Fiber Optic ST type twist lock ee 52 3 8 3 Connecting Fiber Optic SC type Snap In s s s 53 3 8 4 Connecting Single Mode Fiber Optic ee ee eee eeeeeeeeeee 53 3 8 5 Power Budget Calculations
13. to compute the power budget To calculate the power budget of different fiber media installations using Magnum products the following equations should be used OPB Optical Power Budget P min Pp min where Pr Transmitter Output Power and Pp Receiver Sensitivity Worst case OPB OPB 1dB for LED aging 1dB for insertion loss Worst case distance Worst case OPB in dB Cable Loss in dB Km where the Cable Loss for 62 5 125 and 50 125um m m is 2 8 dB km and the Cable Loss for 100 140 Multi mode is 3 3 dB km and the Cable Loss for 9 125 Single mode is 0 5 dB km The following data has been collected from component manufacturer s HP s and Siemens web sites and catalogs to provide guidance to network designers and installers Www GarrettCom com 54 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Fiber Speed ipod Wavel C Port Mode one Size Module a CS14 pa Multi 1300 62 5 125 20 31 9 0 2 5 MST MSC mode 0 4 50 125 23 5 31 A Ea 100Mb Single 20 CS14 SSC py mode 0 4 1300 9 125 15 a Fars 5 si yy Multi 62 5 125 20 31 9 0 ex 0 15 8 Es 5 MTRJ mode 0 A 50 125 23 5 31 5 5 2 0 12 2 40 00Mb Single 40 9 125 34 27 32 5 mae EE oa TE 10 Mb Multi 2 5 31 1 S 9 FL mode 2 3 4 CSN14 10 Mb Single 10 single mode FL mode 5 1300 9 125 30 39 7 14 13 26 55
14. 0 240vac 47 63Hz external power adapter Output 12vdce 1 25Amps International Hi models Factory floor temperature rated Input IEC 320 connector on the 100 240vac 47 63Hz external power adapter Requires a user supplied power cord Output 12vdc 1 25Amps Temperature un controlled Premium P Ratings 40 to 75 C North America Pd models Outdoor temperature rated Input 6ft AC power cord to IEC 320 connector on the100 240vac 47 63Hz external power adapter Output 12vdc 2Amps International Pi models Outdoor temperature rated Input IEC 320 connector on the 100 240vac 47 63Hz external power adapter Requires a user supplied power cord Output 12vdc 2Amps www GarrettCom com 6 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Direct DC POWER SUPPLY built in terminal block for ground along with 12VDC jack 12V DC internal range of 8 0 to 15V DC 24V DC internal range of 18 to 36V DC 48V DC internal range of 36 to 60V DC ground Power Consumption See Section 3 6 Note 1 the 8 15V DC jack can be used for dual source DC input using an AC adapter and the DC terminal block Power supply protection is provided by internal diodes Note 2 The Direct DC power floats The user may ground either or if desired CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Port Connectors Two RJ 45 Ports support 1OOBASE TX and 1OBASE T with
15. 5 C If indoors the DC jack is also present and optionally can be used with an external AC power supply 46 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 29 66 99 DC Power Terminals gnd GND Terminal for earth or ground wire connection to the CS14H chassis Input Voltage 8 15V DC 12V DC 18 36V DC 24V DC 36 60V DC 48V DC Input current 0 8 amp 12V DC 0 4 amp max 24V DC 0 2 amp max 48V DC Power Consumption 4 8 watts typical 6 watts maxm 47 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 3 7 CS14H and P Series DC powered 48VDC 24VDC and 12VDC Installation This section describes the proper connection of the 48VDC leads or 24VDC 12VDC leads to the DC power terminal block on the Magnum CS14H hardened media converter as a 12vo o ONE shown in Figure The DC terminal block on the lt Magnum CS14H is located on the left side of the unit and is equipped with three 3 screw down lead posts The power terminals are identified as positive and negative and they are floating inside the unit so that either of the terminal may be grounded by the user if desired The chassis is earth or ground GND The connection procedure is straightforward Simply insert the DC leads to the CS14H s power terminals positive and negative screws The use of Ground GND ww GarettCom cm
16. C14 TR PS9 and MC14 TR PS9X2 for Rack Mounting Media Converters The MC14 TR PS9 and MC14 TR PS9X2 are other options for rack mounting the mix of Magnum 10Mbps and 100Mbps Converter Switches and Media Converters together in a 19 rack mount tray These models come with built in common universal AC power supply rated at 55 watts at 50 C ambient 12VDC output and supporting up to 10 Switches for MC14 TR PS9 and 16 units CS14 and CSN14 Series for MC14 TR PS9X2 The MC14 Www GarrettCom com 41 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 TR PS9X2 Model has two groups of eight units per power supply The power supplies have auto ranging AC input for use worldwide The side view below is an example of an installation of the model MC14 TR PS9 19 rack mount tray holding a few CS14 and CSN14 FT14 and 14E Media Converters each with their power input plugged into the built in common AC power supply in the rear area of the tray PS units that come with the MC s are not used www GarrettCom com 42 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Metal mounting screws in the bottom front hold each of the media converters securing them in the tray and enabling separate removal for service The dual LEDs permit viewing of Switch status from any angle 3 4 DIN Rail mounting option The Magnum CS14HR CSN14HR and CS14PR CSN14PR Converter Switches designed for use
17. CSN14 Series Converter Switches Installation and User Guide 02 06 higher temperature environments and provide the DC power choices to the user to deploy in uncontrolled temperature environments 12VDC 24VDC 48VDC The Direct DC Internal 12V DC 8 15V DC has a built in terminal block for ground The 9V DC jack is also present Detail information about the 12 VDC the 24V DC and the 48V DC is provided in the Technical Specifications Section 1 1 The various models of DC power type and extended ambient temperature power supplies are numerous and your choice needs to be called out on your order Note When connected to a 48 V centralized dc source these products are to be installed only in Restricted Access Areas dedicated equipment rooms electrical closets or the like 45 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 3 6 Powering the CS14H CSN14H and CS14P CSN14P DC internal with 12V 24V or 48 VDC power input Each Magnum CS14H CS14P Series is reliably equipped with an internal DC power supply and has built in screw terminals for secure attachment of the power leads Three models support a range of power input types The three model choices are for use with 12VDC 24VDC or 48VDC power DC power input may be chosen for high availability The extended temperature capability of the DC powered CS14P s can go temperature uncontrolled environments rated at 40 C to 7
18. P 12VDC model except 24VDC power input replace 12VDC CS14PR ff 24VDC Same as CS14P 24VDC model but includes DIN RAIL MC2 mounting option CS14P ff 48VDC Same as CS14P 24VDC model except 48VDC input replaces 24VDC The ff field is for selection of the desired fiber flavor as listed below Www GarrettCom com 12 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 SC 100Base FX SC multi mode fiber optic with SC type connector 2km SSC 100Base FX SSC single mode fiber optic with SC type connector 20km SSCL 100Base FX SSCL single mode fiber optic with SC type connector 40km ST 100Base FX ST multi mode fiber optic with ST type connector 2km SST 100Base FX ST single mode fiber optic with ST type connector 2km SLC 100Base FX SLC single mode fiber optic with LC type connector 15km MTRJ 100Base FX MTRJ multi mode fiber optic with MTRJ type connector 2km Accessories MC14 TRAY 19 Rack mount tray for 14 series Switch models up to 16 units Other Tray configurations with power supplies and power cabling included See Section 3 3 DIN RAIL MC2 Metal DIN Rail mounting bracket for one CS14 and CSN14 Series Switch See Section 3 4 Conformal Coating for high humidity and tropical applications request quote Www GarrettCom com 13 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 2 0 INTRODUCTION
19. a collision based flow control mechanism when operating at half duplex only When the Switch detects that its free buffer queue space is low the Switch prevents more frames from entering by forcing a collision signal on all receiving half duplex ports in order to stop incoming traffic The latency the time the frame spends in the Switch before it is sent along or forwarded to its destination of the CS14 and CSN14 Series Converter Switches varies with the port speed types The length of the frame is a variable as it is with all store and forward switches For 10 Mb to 10 Mb or 10 Mb to 100Mb or 100Mb to 10 Mb forwarding the latency is 15 microseconds plus the packet time at 10 Mb For 100Mb to 100Mb forwarding the latency is 5 microseconds plus the packet time at 1OOMb 26 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 2 4 Features and Benefits E Full 100Mb or 10 Mb switching services for high performance Ethernet LANs Magnum CS14 and CSN14 Series Switches provide Fast Ethernet switching on all ports They perform high speed filter forward operations on the traffic giving each port s segment a full 1OOMb or 10 Mb of bandwidth E Reduces Network Costs and provide economical solution Magnum CS14 and CSN14 Series Switches offer the ideal solution to efficiently and inexpensively connect a Twisted Pair and fiber network with 10Mb or 100Mb and help to expand the Ethernet network in a very convenient and ec
20. ace divided www GarrettCom com 24 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 evenly across all ports resulting in a small fixed number of packets to be stored per port When the port buffer fills up dropped packets result This dynamic buffer allocation provides the capability for the maximum resources of the Magnum CS14 and CSN14 Series unit to be applied to all traffic loads even when the traffic activity is unbalanced across the ports Since the traffic on an operating network is constantly varying in packet density per port and in aggregate density the Magnum CS14 and CSN14 Series Converter Switches are constantly adapting internally to provide maximum network performance with the least dropped packets When the Switch detects that its free buffer queue space is low the Switch sends industry standard full duplex only PAUSE packets out to the devices sending packets to cause flow control This tells the sending devices to temporarily stop sending traffic which allows a traffic catch up to occur without dropping packets Then normal packet buffering and processing resumes This flow control sequence occurs in a small fraction of a second and is transparent to an observer See Section 4 6 for additional details www GarrettCom com 25 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Another feature implemented in Magnum CS 14 and CSN14 Series Converter Switches is
21. al speed switching environment with standard auto negotiation capability The switched RJ 45 ports are full or half duplex auto sensing for mode and speed and auto cross for plug polarity See Section 2 2 When the connected device is 10 Mbps the CS14s obeys all the rules of 10 Mbps Ethernet configurations The 10 Mbps users can communicate with 100Mbps users as well as other 10 Mbps users through the switch Similarly the 100Mbps traffic obeys the rules of 100Mbps Ethernet and can communicate with 10 Mb and 100Mb users Magnum CS14 and CSN14 Series units are plug and play devices There is no software configuring to be done at installation or for maintenance The only hardware www GarrettCom com 57 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 configuration settings is user options for port 2 to configure it FF AN The internal functions of both are described below Switching Filtering and Forwarding Each time a packet arrives on one of the switched ports the decision is taken to either filter or to forward the packet Packets whose source and destination addresses on the same port segment will be filtered constraining them to one port and relieving the rest of the network from processing them A packet whose destination address is on another port segment will be forwarded to the appropriate port and will not be sent to the other ports where it is not needed Packets needed for maintainin
22. arrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice vi CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 1 0 1 1 SPECIFICATIONS Technical Specifications Ports Performance When a port is operating at 100Mbps Data Rate 100Mbps When a port is operating at 10 Mbps Data Rate 10 Mbps Network Standards 100Mb Ethernet IEEE 802 3u 100BASE TX 100BASE FX 10 Mb Ethernet IEFE 802 3 10BASE T Auto sensing for speed IEEE 802 3u Packet Processing Between Domains Filter and Forward Rate from 100Mbps ports 148 800 pps max Filtering and Forwarding Rate from 10 Mbps ports 14 880 pps max Processing type Store and Forward non blocking Auto learning 2K address table 1 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Address buffer age out time 300 sec Packet buffers memory 128KB dynamically shared on all domains Latency not including packet time 100 to 10 Mbps Sus 10 to 100Mbps 15us Path Delay Value 50 BT on all ports Maximum Ethernet Segment or Domain Lengths 10BASE T Unshielded twisted pair 100 m 328 ft 100BASE TX CAT 5 UTP 100 m 328 ft 100BASE FX half duplex multi mode 412 m 1350 ft 100BASE FX full duplex multi mode 2 km 6 562 ft 100BASE FX half duplex single mode 412 m 1350 ft 100BASE FX full duplex single mode 20 km 65 620 ft 100BASE FX full d
23. be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom com rma rma_request_noaccount php to fill out the form Please have the following information readily available Name and phone number of your contact person Name of your company institution Your shipping address Product name Serial Number or Invoice Number Packing List Number or Sales Order Number Date of installation Failure symptoms including a full description of the problem Www GarrettCom com 66 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 GarrettCom will carefully test and evaluate all returned products will repair products that are under warranty at no charge and will return the warranty repaired units to the sender with shipping charges prepaid see Warranty Information Appendix A for complete details However if the problem or condition causing the return cannot be duplicated by GarrettCom the unit will be returned as No Problem Found GarrettCom reserves the right to charge for the testing of non defective units under warranty Testing and repair of product that is not under warranty will result in a customer user charge Www GarrettCom com 67 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 5 4 Shipping and Packaging Information Should you need to ship the unit back to GarrettCom please follow these i
24. ber Multi mode Single mode 10BASE FL ST Fiber Multi mode 100BASE FX ST SC Fiber Single mode 100BASE FX SC LC Fiber Multi mode 100BASE FX MTRJ NOTE It is recommended that high quality CAT 5 cables which work for both 10 Mbps and 100Mbps be used whenever possible in order to provide flexibility in a mixed speed network since P80 series switch ports are auto sensing for either 10 and 100Mbps Note that the auto cross function does not operate if the port is fixed or not supporting auto negotiation 50 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 3 8 1 Connecting Twisted Pair RJ 45 CAT 3 or CAT 5 Unshielded or Shielded The following procedure describes how to connect a 10BASE T or 1OOBASE TX twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables 1 Using standard twisted pair media insert either end of the cable with a RJ 45 plug into the RJ 45 connector of the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding device 3 Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established If this does not help ensure that the cable is connected properly and that the device on the other end is powered and is not defective
25. ch s memory and inspected before forwarding can occur This technique ensures that all forwarded frames are of a valid length and have the correct CRC i e they are good packets This eliminates propagation of bad packets enabling all of the available bandwidth to be used for valid information 23 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 While other switching technologies such as cut through or express impose minimal frame latency they will also permit bad frames to propagate out to the Ethernet segments connected The cut through technique permits collision fragment frames which are a result of late collisions to be forwarded to add to the network traffic Since there is no way to filter frames with a bad CRC the entire frame must be present in order for CRC to be calculated the result of indiscriminate cut through forwarding is greater traffic congestion especially at peak activity Since collisions and bad packets are more likely when traffic is heavy the result of store and forward operation is that more bandwidth is available for good packets when the traffic load is greatest To minimize the possibility of dropping frames on congested ports each Magnum CS14 and CSN14 Series Converter Switch dynamically allocates buffer space from 128Kb memory pool ensuring that heavily used ports receive very large buffer space for packet storage Many other switches have their packet buffer storage sp
26. d or external AC premium power supply incl CSN14P 12VDC Same as CS14P Pd Pi except AC Premium Power Supply is not included CSN14P 24VDC Same as CS14P 12 VDC model except 24VDC power input replace 12VDC CSN14PR 24VDC Same as CS14P 24VDC model but includes DIN RAIL MC2 mounting option CSN14P 48VDC Same as CS14P 24VDC model except 48 VDC input replaces 24VDC Www GarrettCom com 11 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 CS14 Models for 100Mb fiber CS14 ff d or i two 10 100 RJ 45 one 10Mb ST Fiber port for office and wiring closet 0 to 40C using an external AC power supply CS14H ff Hd Hi Hardened H two RJ 45 one 10Mb Fiber port for factory floor 25 to 60C using a direct DC 8 15 VDC and or external AC hardened power supply included CS14H ff 12VDC Same as CS14H model except AC hardened power supply is not included CS14H ff 24VDC Same as CS14H 12VDC model except 24VDC power input replaces 12VDC CS14HR ff 24VDC Same as CS14H 24VDC model but includes DIN RAIL MC2 mounting option CS14H ff 48VDC Same as CS14H 24VDC model except 48VDC power input replaces 24VDC CS14P ff Pd Pi Premium P two 10 100 RJ 45 one 10Mb Fiber port for un controlled outdoor 40 to 75C using direct DC 8 15VDC and or external AC premium power supply included CS14P ff 12VDC Same as CS14P Pd Pi except AC Premium Power Supply is not included CS14P ff 24VDC Same as CS14
27. e problem continues after completing Step 4 above contact your supplier of the Magnum CS14 and CSN14 Series 10 100 Mb s Switch unit or if unknown contact GarrettCom Inc by fax phone or email support garrettcom com for assistance www GarettCom com 64 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 5 2 When Calling for Assistance Please be prepared to provide the following information 1 A complete description of the problem including the following points The nature and duration of the problem Situations when the problem occurs The components involved in the problem Any particular application that when used appears to create the problem anda 2 An accurate list of GarrettCom product model s involved with serial number s Include the date s that you purchased the products from your supplier 3 It is useful to include other network equipment models and related hardware including Convenient computers workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior www GarrettCom com 65 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 to the occurrence of the problem Any changes to system administration procedures should all be noted in this record 5 3 Return Material Authorization RMA Procedure All returns for repair must
28. en power is ON in the unit If www GarrettCom com 52 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 LINK is not lit after cable connection the normal cause is improper cable polarity Swap the fiber cables at the fiber connector to remedy this situation 3 8 3 Connecting Fiber Optic SC type Snap In The following procedure applies to installations using SC type fiber connectors i e using multi mode SC and SC single mode While connecting fiber media to SC connectors simply snap on the two square male connectors into the SC female jacks of the Fiber connector until it clicks and secures 3 8 4 Connecting Single Mode Fiber Optic When using single mode fiber cable be sure to use single mode fiber port connectors Single mode fiber cable has a smaller diameter than multi mode fiber cable 9 125 microns for single mode 50 125 or 62 5 125 microns for multi mode where xx xx are the diameters of the core and the core plus the cladding respectively Single mode fiber allows full bandwidth at longer distances about 20Km with the multi mode SC The same procedures as for multi mode fiber apply to single mode fiber connectors Follow the steps listed in Section 3 8 2 above www GarrettCom com 53 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 3 8 5 Power Budget Calculations for CS14 and CSN14 Series Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary
29. eo GarrettCom Ethernet at Its Best Magnum CS14 and CSN14 Converter Switches 100Mb Fiber 10 Mb Fiber Installation and User Guide CS14 CSN14 Series Converter Switch Installation and User Guide 02 06 Magnum CS14 and CSN14 Series Converter Switch Installation and User Guide Part 84 00101 Rev A Trademarks GarrettCom Magnum Link Loss Learn S Ring Convenient Switch Converter Switch are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories Important The Magnum CS14 and CSN14 Series 10 100 Mb s Converter Switches contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void If problems are experienced with Magnum CS14 or CSN14 10 100 Mb s Converter Switch products consult Section 5 Troubleshooting of this User Guide Copyright 2006 GarrettCom Inc All rights reserved No part of this publication may be reproduced without prior written permission from GarrettCom Inc Printed in the United States of America i CS14 CSN14 Series Converter Switch Installation and User Guide 02 06 Federal Communications Commission Radio Frequency Interference Statement This equipment generates uses and can radiate frequency energy and if not installed and used properly that is in strict
30. for CS14 Series Fiber Media 54 3 8 6 Connections to NICs which support Auto Neg RJ 45 ports 56 4 0 OPERATION sssssscssccscscessestccssessotscsactecsssascacensessssssocsassecasasabssecseseosncetees 57 4 1 Dual Speed Functionality and Switching ceeseeeeeeeeeeeeeeeeees 57 4 2 Auto cross MDIX Auto negotiation and Speed sensing 59 4 3 F H Switch Full Duplex or Half Duplex options for Fiber port 1 60 4 4 Dual LEDs Front panel and side panel Magnum CS14 and CSN14 61 5 0 TROUBLESHOOTING seesessesesesecceeosoeseseseeceeeroseecesososseseeecoerosoeseeeseee 62 5 1 Before Calling for Assistance seseeseseeeeseseerserreerereersrrrererrsrrrrrrerens 63 5 2 When Calling for Assistance eeeeeeseseeeeesreeeerersrrreerereersrrrrrrereereee 65 5 3 Return Material Authorization RMA Procedure ccsseeeeees 66 Vv CS14 CSN14 Series Converter Switch Installation and User Guide 02 06 5 4 Shipping and Packaging Information 68 APPENDIX A WARRANTY INFORMATION cscscsssssssssssscssesseesees 69 Revisions Rev A 02 06 Change address to Westinghouse Drive Rev A 05 05 Minor updates on Auto cross MDIX functionality Rev A 10 04 Minor updates on power supply option Rev A 09 04 Minor updates on UL requirements and edit Rev A 07 04 Minor updates on Agency approvals and power supplies Rev A 05 04 Initial release of this user manual for CS14 Converter Switches G
31. g the operation of the network such as occasional multi cast packets are forwarded to all ports The Magnum CS 14 and CSN14 Series Converter Switches operate in the store and forward switching mode which Www GarrettCom com 58 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 eliminates bad packets and enables peak performance to be achieved when there is heavy traffic on the network Switching Address Learning The Magnum CS14 and CSN14 Series units have address table capacity of 2K node addresses and are suitable for use in large networks They are self learning so that as nodes are added or removed or moved from one segment to another the CS14 and CSN14 Series switch automatically keeps up with node locations An address aging algorithm causes least used addresses to fall out in favor of new frequently used addresses To reset the address buffer cycle power down and up 4 2 Auto cross MDIX Auto negotiation and Speed sensing The RJ 45 ports support auto cross MDI or MDIX in the auto negotiation mode according to the IEEE 802 3u standard No crossover cables are needed when connecting the CS14 s to other unmanaged switches legacy hubs managed switches www GarrettCom com 59 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 media converters etc Please note that there can be conditions with managed switches where the switch manager fixes the port settings via
32. in Factory Floor Industrial Ethernet environments are also available for DIN Rail mounting in an enclosure having DIN Rails A Magnum CS14H is shown alongside the DIN Rail MC2 bracket The metal DIN Rail mounting hardware is optional and needs to be ordered as a separate item e g Model DIN RAIL MC2 It comes with four screws to attach the bracket to the MC unit The rail clip is spring loaded with a pull up latch at the top for easy snap on attachment and removal www GarrettCom com 43 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 The Magnum CS14 and CSN14 models with HR have 24VDC power and have the DIN Rail MC2 bracket included and assembled with the MC unit at the factory 3 5 Power Requirements Power Supply Types for CS14 and CSN14 Series Switches Magnum CS14 and CSN14 Series Switches are power efficient and can work with an external AC power supply Magnum CS14 and CSN14 Series require a nominal 12VDC input version The extended temperature H and P versions are used for heavy duty industrial applications The 12V DC power input has a plug of 2 5mm center ve with 6 ft cord All the AC power supply info detail is provided in Technical Specifications Section 1 1 The CS14 and CSN14 Series are designed to be used with UL listed Class II power supplies The CS14P S14H converter switches provide reliable operation withstand _wwv GarrettCom com j 44 CS14
33. m 16 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 The Magnum CS14H and CSN14H Hardened units are for factory floor applications The CS14H and CSN14H models are built with high grade components and are constructed using special thermal techniques and a metal case for heavy duty industrial jobs In addition to a Hardened AC power option and jack terminals for internal DC power choices at 8 tol5V 24V or 48V DC are included The ambient temperature rating of 25 to 60C is for industrial use No internal air flow is required for cooling so it resists dust dirt moisture smoke and insects Mounting options include stand alone panel mounting DIN Rail or rack mount tray The Magnum CS14P and CSN14P Premium rated units are for temperature un controlled applications 40 to 75C typically located outdoors The CS14P and CSN14P models are built with premium grade extended temperature components and use similar thermal techniques as the CS14H Hardened units In addition to a Premium rated AC Www GarrettCom com 17 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 power option and jack terminals for internal DC power choices at 8 tol5V 24V or 48V DC are included When used outdoors the CS14P should be protected from falling rain Mounting options include stand alone panel mounting DIN rail or rack mount tray The CSN14 series provides switching between two 10 100 auto negotia
34. ndoor Office CS14 or CSN14 Magnum 6K25 A Ye am fe BES mmm es Router Server Server Tesf compujef 100Mb Servers q and Workstations 10 10Mb Servers and Workstations Data Test computer CS14P Convenient Switches provided a secure dependable reliable solution for un controlled temp environment Www GarrettCom com 32 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 In this example the indoor office location is a Data Mining function with an ongoing demand to grow the network This need can be easily met using the economical Magnum CS14 or CSN14 Converter Switch Additional functionality includes the ability to transfer data across large distances with multi or single mode fiber while securing the LAN from EMI and wire tapping 33 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Example 2 CS14H and CSN14H Magnum 6Kaenn mmmn E Test Station PLC PLC CS14H Converter Switches provided a secure economical solution for expanding Industrial network _wwv GarrettCom com jg 34 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 In this application where in expanding an industrial network environment the new PLC units are deployed on an existing network and each needs one or two for redundancy Ethe
35. nspecting any product returned for warranty repair which turns out not to be faulty Please complete the warranty card as this acts as a product registration and mail it to GarrettCom within two weeks of your purchase Www GarrettCom com 69
36. nstructions 1 Package the unit carefully It is recommended that you use the original container if available Units should be wrapped in a bubble wrap plastic sheet or bag for shipping protection You may retain all connectors and this Installation Guide CAUTION Do not pack the unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 GarrettCom is not responsible for your return shipping charges 4 Ship the package to GarrettCom Inc 47823 Westinghouse Drive Fremont CA 94539 Attn Customer Service 68 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years from the date of shipment by GarrettCom During this warranty period GarrettCom will repair or at its option replace components in the products that prove to be defective at no charge other than shipping and handling provided that the product is returned pre paid to GarrettCom This warranty will not be effective if in the opinion of GarrettCom the product has been damaged by misuse misapplication or as a result of service or modification other than by GarrettCom GarrettCom reserves the right to make a charge for handling and i
37. o repair the unit instead contact your supplier for assistance or contact GarrettCom Customer Support www GarrettCom com 62 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 5 1 Before Calling for Assistance 1 is If difficulty is encountered when installing or operating the unit refer back to the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable Check the cables and connectors to ensure that they have been properly connected and the cables wires have not been crimped or in some way impaired during installation About 90 of network downtime can be attributed to wiring and connector problems Make sure that an AC power cord is properly attached to each Magnum CS14 and CSN14 Series unit Be certain that the AC power cord is plugged into a functioning electrical outlet Use the PWR LEDs to verify each unit 63 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 receiving power 4 If the problem is isolated to a network device other than the Magnum CS14 and CSN14 Series 10 100 Mb s switch product it is recommended that the problem device is replaced with a known good device Verify whether or not the problem is corrected If not go to Step 5 below If the problem is corrected the Magnum CS14 and CSN14 Series Switch and its associated cables are functioning properly J If th
38. on The Magnum CS14P and CSN14P Premium rated versions of Converter Switches have an ambient temperature rating between 40C to 75C for DC models and qualify for temperature un controlled outdoor application E Efficient Compact design for all purpose convenient mounting Featuring a compact steel case with an external AC and internal DC power supply Magnum CS14 and CSN14 Series of Converter Switches can be installed in small spaces in cabinets on table tops in racks wall or DIN rail mounted and in trays such as the Magnum MC14 TRAY m MDIX ports to eliminate cross over cable while cascading All the Magnum CS14 and CSN14 Series Switches are featured with MDIX auto cross which easily allow cascading with other Switch Hubs or media converters without using the cross over cable 29 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 2 5 Applications for CS14 and CSN14 Series Converter Switches Enriched with the three tier Y O R hardness rating flavors Yellow office Orange Hardened Red Premium rated outdoor the multifunctional multi media and multi environmental Magnum CS14 and CSN14 Series Converter Switches fit very well in almost any environment enabling users to scale their networks quickly and cost effectively The edge of the network connectivity solutions offered by Magnum Converter Switches are focused on providing easier more economical and ultra reliable indu
39. onomical way Choice of 10 or 100Mb Fiber option more efficient than media converter Designed as a multi purpose media converter and Switch the 10 or 100Mb fiber port allows the user to convert the media from copper to fiber and the other RJ 45 port can be used as diagnostic port or for more connectivity Www GarrettCom com 27 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 E Installation is Plug and Play operation is transparent to software The Magnum CS14 and CSN14 Series Switches operate as hardware switches only forwarding those packets from each domain that are needed on the other domains Internal address tables are self learning enabling users to change port connections or 10 100 domains without affecting operations E Two sets of LEDs for viewing status from any angle Each CS14 and CSN14 Series Converter Switch is equipped with two sets front and top of LEDs to provide status information when viewed at almost any angle or mounting arrangement whether rack MC14 Tray or wall mounted E Rugged metal case Industrial grade CS14 and CSN14 Series have a robust design and are packaged in a rugged sheet metal enclosure to ensure high reliability and durability even when placed in industrial or outdoor applications www GarrettCom com 28 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Qualified to use for temperature un controlled outdoor applicati
40. rnet ports to carry status and control data to the control center the hardened version of Magnum CS14H or CSN14H is typically used The Fiber port on the converter switches is ideal for secure data communications over long distances that may be encountered in this edge of network application Built with high grade components efficient cooling techniques and having no openings for dirt to enter the CS14 and CSN14 Series Converter Switches provide the very effective solution for this need 35 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Example 3 CS14P or CSN14P Magnum 6K25 memm m enna Ie M I MEN ET e Test Station CCTV C W CCTV Camera amera CCTV Camera www GarrettCom com 36 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 In this example the Magnum CS14P or CSN14P premium Converter Switches are deployed to serve as a secure corporate or transportation surveillance system CCTV cameras may be spread out over many miles in temperature un controlled locations and with pan tilt and zoom PTZ controlled through an Ethernet copper port The premium Converter Switches are ideally suited to providing copper to fiber media conversion for secure long distance 2 40km communication while being installed in temperature un controlled cabinets and allowing a full range of AC and DC power options The second copper port a
41. sociated cabling Make sure the unit is installed in a location that is easily accessible to an AC power outlet or the appropriate DC source and where cooling is not inhibited The green Power PWR LED must turn ON when power is applied 39 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 3 2 MC14 TRAY for Rack Mounting of CS14 and CSN14 Series Switches For 19 rack mounting of Magnum CS14 and CSN 14 series Converter Switches a rack mount tray is available the MC14 TRAY The Converter Switches are mounted with the DC power jack in the back with the fiber and the RJ 45 connectors in the front Any mix of the Converter Switches and or Media Converters may be placed on a tray up to a maximum of 16 units The mounting spaces of the MC14 TRAY are specific to the Magnum products and will not permit other models to be properly mounted www GarrettCom com 40 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 In a typical installation the MC14 TRAY 19 rack mount tray will hold a few three to eight CS14 and CSN14 Series Converter Switches with their power supplies plugged into power strips not included in the rear area of the tray Metal mounting screws in the bottom front hold the Converter Switches firmly in place The beveled top edge of the units permits the LEDs of each unit to be viewed for operational status even when the units are very close together 3 3 M
42. strial application products The compactly designed Magnum CS14 and CSN 14 Series act as very useful tools in the modern life of fast expanding network requirements The Dual Speed and Dual media functions support a mixed environment of 10 Mbps and 100Mbps users with copper and fiber media The switched full half duplex capability on fiber ports provides high bandwidth performance The up link choice of 10 or 100Mb fiber on Port 1 enables easy Www GarrettCom com 30 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 expansion for the on going demand of Ethernet networks The 10 100Mbps auto negotiating copper ports together with the 10 or 100Mbps fiber port choices and the availability of all of the industry standard fiber connectors enable easy interfacing with existing cable plant and equipment The Magnum CS14Ps and CSN14Ps fit very well in high temperature locations experiencing a need to scale the LAN quickly and cost effectively With its half full duplex switching capability on fiber port 1 the CS14Ps provide a very economical high bandwidth solution at each cable user access point of copper and also easily solve long distance requirements The ruggedness of the CS14P s steel case and the high reliability of the design compliments the temperature controlled packaging to provide an exceptional Ethernet product 31 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Example1 I
43. t the remote location provides access for other Ethernet equipment such as motion detectors or will act as a test port for maintenance personnel with up link for access to a central LAN and central file servers 37 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 3 0 INSTALLATION This section describes the installation of the Magnum CS14 and CSN14 Series Converter Switches including location mountings power supply options and media connection 3 1 Locating the Converter Switch Unit All the CS14 and CSN14 Series Switches operate in transparent half and full duplex mode The store and forward switch easily takes care of network traffic and can be used Secure attachment of as a useful economical tool to expand an i P clips for panel existing network 38 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 The compact and lightweight design of the Magnum CS14 and CSN14 Series allows it to be easily installed in almost any location A Velcro strip may be used for mounting the unit on a vertical surface such as a wall or cabinet or for securing the unit on a table top or shelf Alternatively metal mounting clips and screws are included for a rugged and secure mounting in any orientation Installation of the Magnum CS14 and CSN14 Series Converter Switches is a simple procedure The installation location is dependent upon the physical layout of the Ethernet network and as
44. ting copper ports and one 10Mb ST fiber port and the CS14 series provides switching between two 10 100 auto negotiating copper ports and one 100Mb fiber port which may be SC ST MTRJ or LC multi mode or single mode The plug and play energy efficient and flavor rich fiber features make this sleek multi purpose Switch convenient and cost effective for the user The selection of various temperature ranges enable easy deployment in various environments and qualify the Converter Switch as a flexible option which provides multiple solutions using very small space Providing the combination of Media Converter with Switch the CS14 and CSN14 Series is an ideal choice for edge of the network applications Www GarrettCom com 18 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 The labeled Magnum CS14 and CSN14 models as shown in Fig 2 2 a units are for office and wiring closet environments and use an external AC power supply A ventilated metal case for convection cooling is featured Ambient operating temperature is 0 to 40 C Storage temperature rating is 40 to 85 C Metal clips are included for secure panel mounting Fig 2 2a CS14 with 100Mb ST connector 19 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 The ORANGE labeled Magnum CS14H and CSN14H hardened units as shown in Fig 2 2b are designed for factory floor Industrial applications Using special thermal techniq
45. tion performing the auto cross function under auto negotiation mode only The 10Mb fiber CSN14 models are factory configured at Half duplex and 100Mb CS 14 models are factory configured at Full Duplex Two sets of LEDs to indicating the operating status of ports are mounted on the top and front for extra viewing advantage while rack mounted For each port there are Link and Activity LK ACT LED s on the top indicating that the media cables are connected correctly and showing by blinking when there is traffic The LK ACT LED s are repeated on the front as LA1 port 1 LA2 port 2 and LA3 port 3 There is a power PWR indicator on the front of the unit to validate that the unit is turned ON The single fiber port on the CSN14 s is multi mode with an ST connector and on the CS14 s it is an SC ST or small form factor connector MTRJ multi mode or LC Www GarrettCom com 22 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 single mode The Full Duplex Half Duplex F H manual switch provided underneath the fiber port allows the user to fix the fiber port at Full or Half Duplex mode as required The external DC power plug connector and or jack and the internal DC input terminal is provided on the rear of the unit 2 3 Frame Buffering and Latency The Magnum CS14 and CSN14 Series Converter Switches are store and forward switches Each frame or packet is loaded into the Swit
46. ues and a sealed rugged metal case for heavy duty industrial applications no air inflow is required for cooling so the CS14H and CSN14H resist dust dirt moisture smoke and insects Choices of models for external AC or internal DC power are available Ambient operating temperature is 25 C to 60 C depending on the power source used Storage temperature rating is 25 C to 85 C Fig 2 2 b CS14H with 100Mb SC connector 20 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 The RED labeled Magnum CS14P and CSN14P series as shown in Fig 2 2c are premium rated units suitable for temperature un controlled outdoor applications Specially designed with premium grade extended temperature components the CS14P and CSN14P units use similar thermal techniques to the CS14H hardened units for cooling Mounting options include panel mounting DIN rail or rack mount tray Choices of models for external AC or internal DC power are available Ambient operating temperature is between 40 C to 75 C depending on the power source used Storage temperature rating is between 40 C to 85 C Fig 2 2 CS14P with 100Mb SC Connector 21 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 The front side of the unit has two twisted pair 10 100Mb switch ports and one 10 or 100Mb fiber port Both the RJ 45 ports of the CS14 and CSN14 Series Converter switches support auto cross MDIX opera
47. uplex single mode long reach 40 km 131 240 ft 10BASE FL Fiber optic 2 km 6 562 ft 10BASE FL Single mode Fiber optic 10 km 32 8 10ft Www GarrettCom com 2 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Operating Environment CS14 CSN14 32 F to 104 F 0 C to 40 C CS14H CSN14H 13 F to 140 F 25 C to 60 C Long term per agency tests UL 40 F to 149 F 40 C to 85 C Short term per IEC Type tests CS14P CSN14P 40 F to 167 F 40 C to 75 C Long term per agency tests UL 58 F to 212 F 50 C to 100 C Short term per IEC Type tests Storage Temperature All models 40 F to 160 F 40 C to 85 C Cold Start CS14H CSN14H to 20 C CS14P CSN14P to 40 C Ambient Relative Humidity 5 to 95 non condensing Altitude All models 200 to 5000ft 60 15 000 m Conformal Coating optional for humidity protection Note H and P models are designed for NEBS compliance including vibration shock and altitude www GarrettCom com 3 CS14 CSN14 Series Converter Switches Installation and User Guide 02 06 Packaging Enclosure Rugged sheet metal Steel Dimensions of the Switch unit 3 5 in H x 3 0 in W x 1 0 in D 8 9 cm x 7 6 cm x 2 5 cm Weight all models 4 6 oz 130g Power supply d and i 5 9 oz 170g Hd and Hi 5 8 oz 165g Pd and Pi 7 9 oz 225g Cooling Method Convection on the regular model The hardened
Download Pdf Manuals
Related Search
Related Contents
Avaya Desktop Assistant Pro Admin Edition BCM Rls 6.0 User's Manual 2001 US Army TECHNICAL TRAINING 101p Descargar Manual Starting the Video Management System Mettler Toledo Multirange Application software IND690 Télécharger le PDF Print / Save PDF - Pennsylvania Patient Safety Authority JVC LT-26HG22U 26" Full HD Black LED TV Kohler K-3607 User's Manual Samsung Мікро аудіо система MM-C430D Керівництво користувача Copyright © All rights reserved.