Home

Dell OpenManage Server Administrator Version 5.4 SNMP Reference Guide

image

Contents

1. 494 10 Contents Baseboard Management Controller Group Variable Values 498 22 Field Replaceable Unit Group 501 Field Replaceable Unit Group Tables 501 Field Replaceable Unit Table 501 FRU Group Variable Values 505 23 Storage Management Group 507 Storage Management Group 507 Storage Management InformationGroup 509 Global DataGroup 510 Physical DevicesGroup 516 Controller Table 517 Channel Table 534 Enclosure Table 539 Array Disk Table 549 Array Disk Enclosure Connection Table 561 Array Disk Channel Connection Table 563 Fan Tables cn af a ee E a ae eS 566 Fan Connection Table 572 Power Supply Table 574 Power Supply Connection Table 579 Temperature Probe Table 581 Temperature Probe Connection Table 586 Enclosure Management Module Table 588 Enclosure Management Module ConnectionTable 593 BatteryTable 596 Battery Connection Table 602 Contents 11 Logical Devices Group 604 Virtual Disk Table 604 Array Disk Logical Connection Table 613 Storage Management Event Group 616 24 Change Management Group 619
2. 90 Intrusion Table 202 4 93 Baseboard Table 95 Chassis Information Group Variable Values 100 Contents 6 Operating System Group 113 Operating System Group Table 113 Operating System Table 113 Operating System Memory Table 115 7 System Resource Group 119 System Resource Group Tables 119 System Resource Map Table 119 System Resource Owner Table 121 System Resource Input Output 1 0 Port Table scs e s kare kk a eae ae 124 System Resource Memory Table 127 System Resource Interrupt Table 130 System Resource Direct Memory Access DMA Table 133 System Resource Group Variable Values 136 8 Power Group ou5 24 2csut ay cone ee ae 141 Power GroupTables 141 Power UnitTable 141 Power Supply Table 144 Voltage Probe Table 148 Amperage Probe Table 152 AC Power Switch Table 158 AC PowerCordTable 161 BatteryTable 2 163 Power Usage Table 165 Power Group Variable Values 170 Contents 9 Thermal Group 2 2000 52 040 4685 181 Thermal Group Tables 181 Cooling Unit Table 181 Cooling Device Table 184 Temperature Probe Table 189 Ther
3. speakerControlCapable 1 The LRA can issue a speaker beep consoleAlertCapable 2 The LRA can alert the console broadcastMessageCapable 4 The LRA can broadcast a message osShutDownCapable 8 390 The LRA can shut down the operating system Local Response Agent Group Table 17 1 LRA Capabilities Definitions continued Variable Name De 1 LLocalResponseAgentCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value reboot Capable 16 powerCycleCapable 32 powerOFFCapable 64 The LRA can reboot the system The LRA is capable of a system power cycle The LRA can shut the system power off executeApplicationCapable 256 The LRA can execute a user mode lraFullyCapable 383 application The LRA has all of the preceding capabilities Table 17 2 LRA Thermal Shutdown Capabilities Unique Variable Name De 11 LRAThermalShutdownCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value none 0 Unknown capabilities 1 enableCapable 2 warningCapable 4 enableOnWarningCapable 6 failureCapable 8 The LRA has no thermal shutdown capabilities The LRA s thermal shutdown capabilities are unknown The LRA can be disabled offline a binary 0 value or enabled online a binary 1 value The LRA can carry out chassis determined action s when a warning condition is detected The LRA ena
4. 1 Wide Termination 16 bit 2 Narrow Termination 8 bit 3 Not Terminated Integer Read only Channel SCSI ID Name Object ID Description Syntax Access 536 channelSCSIID 1 3 6 1 4 1 674 10893 1 20 130 2 1 6 Identifies the SCSI ID of the controller to which the channel belongs Integer Read only Storage Management Group Channel Roll Up Status Name Object ID Description Syntax Access channelRollUpStatus 1 3 6 1 4 1 674 10893 1 20 130 2 1 7 Identifies the severity of the channel state This is the combined status of the channel and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Channel Component Status Name Object ID Description Syntax Access channelComponentStatus 1 3 6 1 4 1 674 10893 1 20 130 2 1 8 The status of the channel itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Storage Management Group 537 Channel Nexus ID Name channelNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 9 Description Durable unique ID for this channel Syntax DisplayString Access Read only Channel Data Rate Name channelDataRate Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 10 Description Identifies the data rate of this channel Syntax
5. predictiveFailure 1 Battery sensor detects predictive failure failed 2 Battery has failed presenceDetected 4 Battery presence is detected Power Group 179 180 Power Group Thermal Group The Thermal Group provides information about cooling units cooling devices and temperature probes Cooling units are sets of fans or other cooling devices in a system chassis Thermal Group variables include threshold values and types of cooling devices and temperature probes Thermal Group Tables The following management information base MIB tables define the objects in the Thermal Group e Cooling Unit Table e Cooling Unit Status e Temperature Probe Table Cooling Unit Table Name coolingUnitTable Object ID 1 3 6 1 4 1 674 10892 1 700 10 Description Defines the Cooling Unit Table Syntax TableEntry Access Not accessible Cooling Unit Table Entry Name coolingUnitTableEntry Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 Description Defines the Cooling Unit Table entry Syntax TableEntry Access Not accessible Index coolingUnitchassisIndex coolingUnitIndex Thermal Group 181 Cooling Unit Chassis Index Name coolingUnitchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 1 Description Defines the index one based of this chassis Syntax TableEntry Access Read only Cooling Unit Index Name coolingUnit Index Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 2 Description Defines the index one bas
6. 1 Disabled 2 Enabled Integer Read only Storage Management Group 545 Enclosure Backplane Part Number Name enclosureBackplanePartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 21 Description Identifies the part number of the enclosure s backplane Syntax Integer Access Read only Enclosure SCSI ID Name enclosureSCSIID Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 22 Description Identifies the SCSI ID of the controller to which this enclosure is attached Syntax Integer Access Read only Enclosure Roll Up Status Name enclosureRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 23 Description Identifies the severity of the enclosure state This is the combined status of the enclosure and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 546 Storage Management Group Enclosure Component Status Name enclosureComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 24 Description The status of the enclosure itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Enclosure Nexus ID Name enclosureNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 25 Description Durable unique ID for this enclosure Syntax Integer Access Read only E
7. 20000005 667 26 Storage Management Alert Reference 673 Alert Monitoring andLogging 673 Viewing Alerts 2 000 673 Alert Severity Levels 674 SNMP Support for Storage Management Alerts 675 SNMP Trap Forwarding 675 SNMP Trap Definitions 675 SNMP Trap Variables 676 ViewingSNMPTraps 676 Alert Descriptions and Corrective Actions 676 Contents 13 A Standard Data Type Definitions 677 Common DataTypes 677 Variables with Data Types of State Capabilities and State Capabilities Unique 678 Dell Status DataTypes 680 Dell Dat scia 83 5 a ha ee eS 681 Full Dates os ce ee ee a ee Pa 682 B SNMP Sample Output 683 GIOSSATY wo 5 aradenn see Duar nuts Gees 689 WG ON sean st apc oh le ode dee reg a aces er eRe 727 Contents Introduction This introduction is divided into two sections The first section Introduction to the SNMP Reference Guide explains the SNMP Reference Guide design All essential Simple Network Management Protocol SNMP terms are defined in this section Some of the vocabulary may seem complex and unfamiliar to system administrators who are using SNMP for the first time SNMP experts can skim this section and beginners can read the section more carefully The second section Introducti
8. Access Read write Remote Access Out of Band Simple Network Management Protocol SNMP Capabilities Name remoteAccessOutOfBandSNMPCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 18 Description Defines the out of band SNMP capabilities of the remote access hardware Syntax DellRemoteAccessOutOfBandSNMPCapabilities See Table 19 10 Access Read only 438 Remote Access Group Remote Access Out of Band SNMP Settings Name remoteAccessOutOfBandSNMPSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 19 Description Defines the out of band SNMP settings of the remote access hardware Syntax DellRemoteAccessOutOfBandSNMPSettings See Table 19 11 Access Read write Remote Access Simple Mail Transfer Protocol SMTP Server Internet Protocol IP Address Name remoteAccessSMTPServerIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 20 Description Defines the IP address for the SMTP server used by the remote access hardware Syntax IpAddress Access Read write Remote Access Floppy Trivial File Transfer Protocol TFTP IP Address Name remoteAccessFloppyTFTPIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 21 Description Defines the IP address of the TFTP server providing the operating system image used by the remote access hardware Syntax IpAddress Access Read write Remote Access Floppy TFTP Path Name Name remoteAccessFloppyTFTPPathName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 22 Description
9. BIOS Setup Control Group 379 Table 16 12 Parallel Port Control Capabilities Variable Name De11ParallelPortControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 enableCapable 2 allParallelPortCapable 30 lpt1Capable 4 lptlandEnableCapable 6 lpt2Capable 8 lpt2andEnableCapable 10 lpt3Capable 16 lpt3andEnableCapable 18 Setup BIOS parallel port capabilities are unknown Setup BIOS can enable the parallel port Setup BIOS can support parallel port 1 Setup BIOS has enabled parallel port 1 Setup BIOS can support parallel port 2 Setup BIOS has enabled parallel port 2 Setup BIOS can support parallel port 3 Setup BIOS has enabled parallel port 3 Setup BIOS can support any of the three parallel ports Table 16 13 Parallel Port Control Settings Variable Name De11ParallelPortControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Parallel port state is unknown enabled 2 Setup BIOS has enabled the parallel port lpt1 4 Setup BIOS supports parallel port 1 lpt1Enabled 6 Setup BIOS has enabled parallel port 1 lpt2 8 Setup BIOS supports parallel port 2 lpt2Enabled 10 Setup BIOS has enabled parallel port 2 lpt3 16 Setup BIOS supports parallel port 3 380 BIOS Setup Control Group Table 16 14 Parallel Port Control Mode Settings Variable Name De11P
10. Data Type Integer Possible Data Values Meaning of Data Value deviceTypelIsOther 1 deviceTypelIsUnknown 2 deviceTypeIsCPU 3 deviceTypelIsMathProcessor 4 deviceTypeIsDSP 5 deviceTypelIsAVideoProcessor 6 The processor device type is not one of the following values The processor device type is unknown The processor device type is a central processing unit The processor device type is a math processor The processor device type is a digital signal processor The processor device is a video I processor Device Group 293 294 Table 13 5 Processor Upgrade Information Variable Name De1lProcessorUpgradeInformation Data Type Integer Possible Data Values Meaning of Data Value processor processor processor processor processor processor processor processor processor processor processor processor processor processor processor processor processor UpgradeIsOther 1 UpgradeIsUnknown 2 UpgradeIsByDaughterBoard 3 UpgradeIsByZIFSocket 4 UpgradeIsByReplacement 5 UpgradeIsNone 6 UpgradeIsByLIFSocket 7 UpgradeIsBySlot1 8 UpgradeIsBySlot2 9 UpgradeIsBy370PinSocket 10 UpgradeIsBySlotA 11 UpgradeIsBySlotM 12 UpgradeIsByScoket423 13 UpgradeIsBySocketA 14 UpgradeIsBySocket478 15 UpgradeIsBySocket754 16 UpgradeIsBySocket940 17 Device Group The upgrade device type
11. Defines the 64 bits of the ending address of the system resource memory DellUnsigned64BitRange Read only System Resource Group 129 System Resource Memory Flags Name systemResourceMemoryFlags Object ID 1 3 6 1 4 1 674 10892 1 500 40 1 10 Description Defines the permission flags for the system resource memory Syntax DellResourceMemoryFlags See Table 7 4 Access Read only System Resource Interrupt Table Name systemResourceInterruptTable Object ID 1 3 6 1 4 1 674 10892 1 500 50 Description Defines the System Resource Interrupt Table Syntax SEQUENCE OF SystemResourcelnterruptTableEntry Access Not accessible System Resource Interrupt Table Entry Name systemResourcelInterruptTableEntry Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 Description Defines the System Resource Interrupt Table entry Syntax SystemResourcelnterrupt TableEntry Access Not accessible Index systemResourcelnterruptchassisIndex systemResourcelnterruptIndex System Resource Interrupt Chassis Index Name systemResourceInterruptchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Not accessible 130 System Resource Group System Resource Interrupt Index Name Object ID Description Syntax Access systemResourcelInterrupt Index 1 3 6 1 4 1 674 10892 1 500 50 1 2 Defines the index one based of this interrupt resourc
12. Name cooLeaseInformationTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 Description Defines the COO Lease Information Table entry Syntax CooLeaseInformation TableEntry Access Not accessible Index cooLeaselnformationchassisIndex cooLeaseInformationIndex COO Lease Information Chassis Index Name cooLeaseInformationchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only 410 Cost of Ownership Group COO Lease Information Index Name Object ID Description Syntax Access cooLeaseInformat ionIndex 1 3 6 1 4 1 674 10892 1 1600 50 1 2 Defines the index of the lease information for this system DellObjectRange Read only COO Lease Information State Name Object ID Description Syntax Access cooLeaseInformationState 1 3 6 1 4 1 674 10892 1 1600 50 1 3 Defines the lease information state for this system DellStateSettings Read write C00 Lease Information Multiple Schedules Name Object ID Description Syntax Access cooLeaseInformationMultipleSchedules 1 3 6 1 4 1 674 10892 1 1600 50 1 4 Defines whether there are multiple schedules for this lease DellBoolean Read only COO Lease Information Buyout Amount Name Object ID Description Syntax Access cooLeaseInformationBuyOutAmount 1 3 6 1 4 1 674 10892 1 1600 50 1 5 Defines the balance purchase price for this system DellUnsigned32
13. Name remot eUserAdminChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellObjectRange Access Read only Remote User Admin Adapter Index Name remot eUserAdminAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 2 Description Defines the index one based of the remote access hardware used by this remote access user Syntax DellObjectRange Access Read only Remote User Admin User Index Name remot eUserAdminUserIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 3 Description Defines the index one based of this remote access user Syntax DellObjectRange Access Read only Remote User Admin State Capabilities Name remoteUserAdminStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 4 Description Defines the state capabilities for this remote access user Syntax DellRemoteUserAdminStateCapabilities See Table 19 12 Access Read only 444 Remote Access Group Remote User Admin State Settings Name remoteUserAdminStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 5 Description Defines the state settings for this remote access user Syntax DellRemoteUserAdminStateSettings See Table 19 13 Access Read write Remote User Admin Status Name remoteUserAdminStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 6 Description Defines the status for this remote access user Syntax DellStatus
14. temperatureProbeProbeCapabilities 1 3 6 1 4 1 674 10892 1 700 20 1 15 Defines the probe capabilities of the temperature probe DellProbeCapabilities Read only Temperature Probe Discrete Reading Name Object ID Description Syntax Access 194 temperatureProbeDiscreteReading 1 3 6 1 4 1 674 10892 1 700 20 1 16 Defines the reading for a temperature probe of type temperatureProbeTypelsDiscrete When the value for temperatureProbeType is other than temperatureProbeTypelsDiscrete a value is not returned for this attribute When the value for temperatureProbeType is temperatureProbeTypelsDiscrete the value returned for this attribute is the discrete reading for the probe Dell TemperatureDiscreteReading See Table 9 5 Read only Thermal Group Thermal Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 9 1 Cooling Device Type Variable Name De11CoolingDeviceType Data Type Integer Possible Data Values Meaning of Data Value coolingDeviceTypelIsOther 1 The cooling device type is not one of the following coolingDeviceTypelIsUnknown 2 The cooling device type is unknown not known or not monitored coolingDeviceTypelIsAFan 3 The cooling device type is a fan coolingDeviceTypelIsABlower 4 The cooling device type is a centrifugal blower coolingDeviceTypelIsAChipFan 5 The cooling device type is a
15. 1 3 6 1 4 1 674 10892 1 03 03 03 03 03 1 3 6 1 4 1 674 10892 1 02 02 02 02 02 02 684 SNMP Sample Output 200 200 200 200 10 10 10 10 ws ale T 1 20 21 22 23 1 3 6 1 4 1 674 10892 1 3 6 1 4 1 674 10892 03 03 03 03 03 03 1 3 6 1 4 1 674 10892 02 02 02 02 1 3 6 1 4 1 674 1 3 6 1 4 1 674 03 03 03 03 1 3 6 1 4 1 674 Lies Ly Ey des 3 3 3 64 6d nH Hn HH HH DH DH BH HW WA 6 1 salts 1 Chassis 1 3 6 13365 2650 1 3 6 13 65 dedi 6 2 Ta L 4 Ae A FF FF FF FF FF A A A A WS sL anl 674 674 674 674 674 674 674 674 674 674 674 674 674 674 674 674 674 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 200 200 200 200 200 200 200 200 200 200 200 300 300 300 300 300 300 300 300 300 300 300 300 10 LO 10 mel Os 04 10 STON 10 LOs 10 a LO 10 10 10 10 10 10 eLO 10 10 10 10 10 YN nO Ww fs H 24 1 tied 26 1 edhe 28 1 Pay ac eral 30 1 BLI 41 1 242 1 43 1 ee H sL Fa a a E 212 1 Il ll 02 03 03 0
16. 467 Table 19 3 Remote Access Control Settings continued Variable Name Del 1RemoteAccessControlSettings Data Type Integer Possible Data Values Meaning of Data Value gracefulReset 16 The remote access hardware will gracefully shut down and perform a soft reset defaultConfigReset 32 The remote access hardware will reset to its default settings shutdown 64 The remote access hardware will shut down Table 19 4 Remote Access Monitor Capabilities Variable Name De 1 1LRemoteAccessMonitorCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 le he remote access hardware has no nonitor capabilities unknownCapabilities 1 The remote access hardware monitor capabilities are unknown extPwrSupplyMonitorIfConn The remote access hardware can be set to ectedCapable 2 monitor the external power supply if connected extPwrSupplyMonitorAlways The remote access hardware can be set to EnabledCapable 4 always monitor the external power supply 468 Remote Access Group Table 19 5 Remote Access Monitor Settings Variable Name Del 1RemoteAccessMonitorSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 unknown 1 ext PwrSupplyMonitorIfConn ectedEnabled 2 ext PwrSupplyMonitorAlways EnabledEnabled 4 The remote access hardware has no monitor settings e he remote ac
17. Access Read only Device Group 263 Cache Device Error Checking and Correction ECC Type Name Object ID Description Syntax Access cacheDeviceECCType 1 3 6 1 4 1 674 10892 1 1100 40 1 17 Defines the type of error correction in use by the cache device DellCacheDeviceECCType See Table 13 11 Read only Cache Device Associativity Name Object ID Description Syntax Access cacheDeviceAssociativity 1 3 6 1 4 1 674 10892 1 1100 40 1 18 Defines the type of associativity in use by the cache device DellCacheDeviceAssociativity See Table 13 12 Read only Cache Device Supported Type Name Object ID Description Syntax Access cacheDeviceSupportedType 1 3 6 1 4 1 674 10892 1 1100 40 1 19 Defines the type of static random access memory SRAM that the cache device can support DellCacheDeviceSupported Type Read only Cache Device Current Type Name Object ID Description Syntax Access 264 cacheDeviceCurrentType 1 3 6 1 4 1 674 10892 1 1100 40 1 20 Defines the current type of SRAM for the cache device DellCacheDeviceSRAMType See Table 13 14 Read only Device Group Memory Device Table Name Object ID Description Syntax Access memoryDeviceTable 1 3 6 1 4 1 674 10892 1 1100 50 Defines the Memory Device Table SEQUENCE OF MemoryDeviceTableEntry Not accessible Memory Device Table Entry Name Object ID Description Syntax Access Index memoryD
18. Access Read only Parallel Port Control Index Name parallelPortControliIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 30 1 2 Description Defines the index one based of the parallel port in this chassis Syntax DellObjectRange Access Read only 362 BIOS Setup Control Group Parallel Port Control Capabilities Unique Name Object ID Description Syntax Access parallelPortControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1400 30 1 3 Defines the capabilities of the parallel port DellParallelPortControlCapabilitiesUnique See Table 16 12 Read only Parallel Port Control Settings Unique Name Object ID Description Syntax Access parallelPortControlSettingsUnique 1 3 6 1 4 1 674 10892 1 1400 30 1 4 Defines the state of the parallel port DellParallelPortControlSettingsUnique See Table 16 13 Read only Parallel Port Control Status Name Object ID Description Syntax Access parallelPortControlStatus 1 3 6 1 4 1 674 10892 1 1400 30 1 5 Defines the status of the parallel port DellStatus Read only Parallel Port Control Name Name Object ID Description Syntax Access parallelPortControlName 1 3 6 1 4 1 674 10892 1 1400 30 1 6 Defines the setup BIOS name of the parallel port DellString Read only BIOS Setup Control Group 363 Parallel Port Control Mode Capabilities Unique Name parallelPortControlModeCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 30 1 7 Description
19. DellObjectRange Read only Pointing Device Index Name Object ID Description Syntax Access pointingDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 10 1 2 Defines the index of the pointing device in this chassis DellObjectRange Read only Pointing Device State Capabilities Name Object ID Description Syntax Access 244 pointingDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 10 1 3 Defines the capabilities of the pointing device DellStateCapabilities Read only Device Group Pointing Device State Settings Name Object ID Description Syntax Access pointingDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 10 1 4 Defines the state of the pointing device DellStateSettings Read write Pointing Device Status Name Object ID Description Syntax Access pointingDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 10 1 5 Defines the status of the pointing device DellStatus Read only Pointing Port Index Reference Name Object ID Description Syntax Access pointingPort IndexReference 1 3 6 1 4 1 674 10892 1 1100 10 1 6 Defines the index to the pointing port in this chassis DellObjectRange Read only Pointing Device Type Name Object ID Description Syntax Access pointingDeviceType 1 3 6 1 4 1 674 10892 1 1100 10 1 7 Defines the type of the pointing device DellPointingDeviceType See Table 13 1 Read only Device Group 245 Pointing Device Number of Buttons Name p
20. Device type is RAM Device type is ROM Device type is FLASH Device type is EEPROM Device type is FEPROM Device type is EPROM Device type is CDRAM Device type is 3 DRAM Device Group 305 Table 13 16 Memory Device Type continued Variable Name De1 1MemoryDeviceType Data Type Integer Possible Data Values Meaning of Data Value deviceTypeIsSDRAM 15 Device type is SDRAM deviceTypeIsSGRAM 16 Device type is SGRAM deviceTypeIsRDRAM 17 Device type is RDRAM deviceTypeIsDDR 18 Device type is DDR deviceTypeIsDDR2 19 Device type is DDR2 deviceTypeISDDR2FBDIMM 20 Device type is DDR2 FB DIMM Table 13 17 Memory Device Type Details Variable Name De 1 1MemoryDeviceTypeDetails Data Type Integer Possible Data Values Meaning of Data Value deviceTypeDeatilIsOther 1 deviceTypeDetailIsUnknown 2 deviceTypeDetaillIsFastPaged 3 deviceTypeDetailIsStaticColumn 4 deviceTypeDetailIsPseudoStatic 5 deviceTypeDetailIsSRAMBUS 6 deviceTypeDetailIsSynchronous 7 deviceTypeDetailIsCMOSs 8 306 Device Group The detailed device type is not one of the following The detailed device type is unknown The detailed device type is fast paged The detailed device type is static column The detailed device type is pseudo static The detailed device type is RAMBUS The detailed device type is synchronous The detailed device type is CMOS Table 13 17
21. Storage Management Group Virtual Disk Read Policy Name Object ID Description Syntax Access virtualDiskReadPolicy 1 3 6 1 4 1 674 10893 1 20 140 1 1 11 Indicates whether the controller s read cache will be used when reading from a virtual disk Possible values 1 Enabled Adaptec Read Cache Enabled 2 Disabled Adaptec Read Cache Disabled 3 LSI Read Ahead 4 LSI Adaptive Read Ahead 5 LSI No Read Ahead Integer Read only Virtual Disk Cache Policy Name Object ID Description Syntax Access virtualDiskCachePolicy 1 3 6 1 4 1 674 10893 1 20 140 1 1 12 Indicates whether the controller s cache is used when reading from or writing to a virtual disk Possible values 1 Direct I O LSI 2 Cached I O LSI 99 Not Applicable Integer Read only Storage Management Group 609 Virtual Disk Layout Name virtualDiskLayout Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 13 Description Indicates the virtual disk s RAID type Possible values 1 Concatenated 2 RAID 0 3 RAID 1 7 RAID 5 8 RAID 6 10 RAID 10 12 RAID 50 19 Concatenated RAID 1 24 RAID 60 Syntax Integer Access Read only Virtual Disk Current Stripe Size in Megabytes Name virtualDiskCurStripeSizeInMB Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 14 Description Identifies the stripe size of this virtual disk in megabytes If this size is 0 it is smaller than a megabyte Syntax Integer Access Read only 610 Storage
22. fanProbeMinimumCritical 1 3 6 1 4 1 674 10893 1 20 130 7 1 8 This entry is obsolete This setting is not supported by fans managed under Storage Management DisplayString Read only Fan Probe Maximum Warning Name Object ID Description Syntax Access fanProbeMaximumWarning 1 3 6 1 4 1 674 10893 1 20 130 7 1 9 This entry is obsolete This setting is not supported by fans managed under Storage Management DisplayString Read only Fan Probe Maximum Critical Name Object ID Description Syntax Access fanProbeMaximumCritical 1 3 6 1 4 1 674 10893 1 20 130 7 1 10 This entry is obsolete This setting is not supported by fans managed under Storage Management DisplayString Read only Storage Management Group 569 Fan Probe Current Value Name fanProbeCurrValue Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 11 Description Identifies the current speed of the fan Syntax DisplayString Access Read only Fan1 Part Number Name fanlPartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 12 Description Identifies the part number of the fan in the enclosure Syntax DisplayString Access Read only Fan 2 Part Number Name fan2PartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 13 Description This entry is obsolete This setting is not supported by fans managed under Storage Management Syntax DisplayString Access Read only 570 Storage Management Group Fan Roll Up Status Na
23. https lt IP address gt lt 1311 or user specified port number gt To manage a system locally using Server Administrator type the following in the address field of your browser https localhost lt 1311 or user specified port number gt Systems Management Software Group 39 Systems Management Software The following objects describe the fields for server administrator systems management information The systems management software variables are scalar objects meaning that they are not related to other management information base MIB objects and are thus not placed in a table Systems Management Software Name Name systemManagementSoftwareName Object ID 1 3 6 1 4 1 674 10892 1 100 1 Description Defines the systems management software product name Syntax DellString Access Read only Systems Management Software Version Number Name Name systemManagementSoftwareVersionNumberName Object ID 1 3 6 1 4 1 674 10892 1 100 2 Description Defines the version number of the systems management software Syntax DellString Access Read only Systems Management Software Build Number Name systemManagement SoftwareBuildNumber Object ID 1 3 6 1 4 1 674 10892 1 100 3 Description Defines the build number of the systems management software Syntax DellUnsigned16BitRange Access Read only 40 Systems Management Software Group Systems Management Software Description Name Name systemManagementSoftwareDescriptionName Object
24. on 135 deviceFamilyIsAMDAthlon64X2Dual Core 136 deviceFamilyIsAMDTurion64X2Mob ile 137 deviceFamilyIsQuadCoreAMDOpter on 138 deviceFamilyIsThirdGeneration AMDOpteron 139 deviceFamilyIsPA RISC 144 deviceFamilyIsPA RISC8500 145 deviceFamilyIsPA RISC8000 146 deviceFamilyIsPA RISC7300LC 147 deviceFamilyIsPA RISC7200 148 deviceFamilyIsPA RISC7100LC 149 deviceFamilyIsPA RISC7100 150 deviceFamilyIsv30 160 deviceFamilyIsM1 176 deviceFamilyIsM2 177 deviceFamilyIsAS400 180 deviceFamilyIsAMDAthlonxP 182 deviceFamilyIsAMDAthlonMP 183 deviceFamilyIsAMDDuron 184 Opteron The processor family is AMD Athlon 64 X2 Dual Core The processor family is AMD Turion 64 X2 Mobile Technology The processor family is Quad Core AMD Opteron The processor family is third generation AMD Opteron The processor family is PA RISC The processor family is PA RISC 8500 The processor family is PA RISC 8000 The processor family is PA RISC 7300LC The processor family is PA RISC 7200 The processor family is PA RISC 7100LC The processor family is PA RISC 7100 The processor family is V30 The processor family is M1 The processor family is M2 The processor family is AS400 The processor family is AMD Athlon XP The processor family is AMD Athlon MP The processor family is AMD Duron Device Group 299 Table 13 6 Processor Device Family continued
25. 1 3 6 1 4 1 674 10892 1 1400 70 1 4 Defines the control settings for the diskette controller DellDisketteControlSettingsUnique Read only BIOS Setup Control Group 371 Diskette Control Status Name disketteControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 70 1 5 Description Defines the status of the diskette controller Syntax DellStatus Access Read only Diskette Control Name Name disketteControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 70 1 6 Description Defines the setup BIOS name of the diskette controller Syntax DellString Access Read only Network Interface Control Table These MIB objects enable you to track the attributes of the NIC card for your system Name networkInterfaceControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 80 Description Defines the Network Interface Control Table Syntax NetworkInterfaceControl TableEntry Access Not accessible 372 BIOS Setup Control Group Network Interface Control Table Entry Name Object ID Description Syntax Access Index networkInterfaceControlTableEntry 1 3 6 1 4 1 674 10892 1 1400 80 1 Defines the Network Interface Control Table entry NetworkInterfaceContro TableEntry Not accessible networkInterfaceControlchassisIndex networkInterfaceControllndex Network Interface Control Chassis Index Name Object ID Description Syntax Access networkInterfaceControlchassisIndex 1 3 6 1 4 1 674 10892 1 1400 80 1 1 Defines the index one bas
26. 23 Main System Dell Inc PowerEdge ASSETTAG 1234567 254 SNMP Sample Output 685 1 ule diss 233 3 3 n HD OA 6 sees ae ie ale 4 4 4 4 I lt L 1 674 674 674 674 20050513095213 1 3 6 1 4 1 674 20050513100052 1 3 6 1 4 1 674 the value 13 M A the dy us the dt Ty 686 w w W W U U UU UW Ww w W W Lz 1 value hoped lee ed ee value 6 0245 6 4 6 254 6 2452 6 14 1 baL smal 661742 6 104021 26 0 4 6 AL 6 01451 16s E42 26 1 4 21 26024 aL Oxo Li 22 674 674 674 674 674 674 674 674 674 674 674 674 674 674 674 674 674 10892 10892 10892 10892 1 L I 300 300 300 300 000000 360 10892 1 300 000000 360 10892 1 300 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 SNMP Sample Output 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 300 10 O s TOs 10 LO s 1 0a 10 10 10 10 10 0 10 5 10 10 10 10 10 tO 1 03 10 10 10 13 14 LES Le Me Dy A L8 19 20 AA te r 22is 23 24 25 26 eds 28 29 30 ein er 32 33 34 3D 289 4 SERVERO1
27. 8 Load balancing teaming mode Device Group 309 Table 13 22 Network Device TOE Capability Flags Variable Name De1 1NetworkDeviceTOECapabilityFlags Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value none 0 unknown 1 available 2 notAvailable 4 cannotBeDetermined 8 driverNotResponding 16 Querying for TOE capability is not supported Querying for TOE capability is supported but query returned an error Device has TOE capability Device does not have TOE capability Querying for TOE capability is supported but an error prevented querying Querying for TOE capability is supported but driver did not respond to query Table 13 23 Network Device RDMA Capability Flags Variable Name De1 1NetworkDeviceRDMACapabilityFlags Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value none 0 unknown 1 available 2 notAvailable 4 cannotBeDetermined 8 driverNotResponding 16 Querying for RDMA capability is not supported Querying for RDMA capability is supported but query returned an error Device has RDMA capability Device does not have RDMA capability Querying for RDMA capability is supported but an error prevented querying Querying for RDMA capability is supported but driver did
28. Access Read only PCI Device State Settings Name pCIDeviceStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 4 Description Defines the state of the PCI device Syntax DellStateSettings Access Read write PCI Device Status Name pCIDeviceStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 5 Description Defines the status of the PCI device Syntax DellStatus Access Read only Device Group 279 PCI Device System Slot Index Reference Name Object ID Description pCiIDeviceSystemSlot IndexReference 1 3 6 1 4 1 674 10892 1 1100 80 1 6 Defines the index number of the system slot that this PCI device is in Syntax DellObjectRange Access Read only PCI Device Data Bus Width Name pCIDeviceDataBusWidth Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 7 Description Defines the bus width of the PCI device in this chassis Syntax DellUnsigned32BitRange Access Read only PCI Device Manufacturer Name Name Object ID Description Syntax Access pCIDeviceManufacturerName 1 3 6 1 4 1 674 10892 1 1100 80 1 8 Defines the name of the PCI device manufacturer DellString Read only PCI Device Description Name Name Object ID Description Syntax Access 280 pCiIDeviceDescriptionName 1 3 6 1 4 1 674 10892 1 1100 80 1 9 Defines the descriptive name of the PCI device DellString Read only Device Group PCI Device Speed Name Object ID Description pCIDeviceSpeed 1 3 6 1 4 1 674 10892 1 1100 80 1
29. Access Read only Remote User Admin User Name Name remot eUserAdminUserName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 7 Description Defines the user name for this remote access user Syntax DisplayString SIZE 0 19 Access Read write Remote User Admin User Password Name Name remot eUserAdminUserPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 8 Description Defines the password for this remote access user Syntax DisplayString SIZE 0 255 Access Read write Remote Access Group 445 Remote User Admin User Privilege Name remot eUserAdminUserPrivilege Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 9 Description Defines the privileges for this remote access user Syntax DisplayString SIZE 0 31 Access Read write Remote User Admin User Privilege Capabilities Name remoteUserAdminUserPrivilegeCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 10 Description Defines the privilege capabilities for this remote access user Syntax DisplayString SIZE 0 31 Access Read only Remote User Admin Alert Filter DRS Events Mask Name remoteUserAdminAlertFilterDrsEventsMask Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 11 Description Defines the DRS events filter mask for this remote access user Syntax DellUnsigned32BitRange Access Read write Remote User Admin Alert Filter System Events Mask Name remoteUserAdminAlertFilterSysEvent sMask Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 12 Descripti
30. Access Read write Amperage Probe Lower Noncritical Threshold Name amperageProbeLowerNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 12 Description Defines the user assigned value of the amperage probe s lower noncritical threshold Syntax DellSigned32BitRange Access Read write 156 Power Group Amperage Probe Lower Critical Threshold Name amperageProbeLowerCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 13 Description Defines the value of the amperage probe s lower critical threshold Syntax DellSigned32BitRange Access Read only Amperage Probe Lower Nonrecoverable Threshold Name amperage ProbeLowerNonRecoverableThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 14 Description Defines the value of the amperage probe s lower nonrecoverable threshold Syntax DellSigned32BitRange Access Read only Amperage Probe Probe Capabilities Name amperageProbeProbeCapabilities Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 15 Description Defines the probe capabilities of the amperage probe Syntax DellProbeCapabilities Access Read only Power Group 157 Amperage Probe Discrete Reading Name amperageProbeDiscreteReading Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 16 Description Defines the reading for a amperage probe of type amperageProbelypelsDiscrete When the value for amperageProbeype is other than amperageProbelypelsDiscrete a value is not returned for this attribute When
31. Defines the index of the memory port of which this memory device is part DellObjectRange Read only Device Group Memory Device Type Name memoryDeviceType Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 7 Description Defines the type of the memory device Syntax DellMemoryDeviceType See Table 13 16 Access Read only Memory Device Location Name Name memoryDeviceLocationName Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 8 Description Defines the location name of the memory device Syntax DellString Access Read write Memory Device Error Count K NOTE Memory Device Failure Modes has now replaced this attribute Memory Device Error Count should no longer be used If you use the Memory Device Error Count attribute the value returned is always zero and using the attribute will have no effect Name memoryDeviceErrorCount Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 9 Description Defines the total number of Error Checking and Correction ECC errors detected by the memory device Writing a 0 zero to this variable will reset the devices error counts Syntax DellSigned32BitRange Access Read write Device Group 267 Memory Device Bank Location Name Name Object ID Description Syntax Access memoryDeviceBankLocat ionName 1 3 6 1 4 1 674 10892 1 1100 50 1 10 Defines the bank location name of the memory device DellString Read only Memory Device Type Details Name Object ID Description Synta
32. DellStatusProbe Read only Temperature Probe Reading Name Object ID Description Syntax Access temperatureProbeReading 1 3 6 1 4 1 674 10892 1 700 20 1 6 Defines the value of the temperature probe When the value for temperatureProbeType is other than temperatureProbeTypelsDiscrete the value returned for this attribute is the temperature that the probe is reading in tenths of degrees Centigrade When the value for temperatureProbeType is temperatureProbeTypelsDiscrete a value is not returned for this attribute DellSigned32BitRange Read only Thermal Group 191 Temperature Probe Type Name Object ID Description Syntax Access temperatureProbeType 1 3 6 1 4 1 674 10892 1 700 20 1 7 Defines the temperature probe type Dell TemperatureProbeType See Table 9 4 Read only Temperature Probe Location Name Name Object ID Description Syntax Access temperatureProbeLocat ionName 1 3 6 1 4 1 674 10892 1 700 20 1 8 Defines the location of the temperature probe in this chassis DellString Read only Temperature Probe Upper Nonrecoverable Threshold Name Object ID Description Syntax Access temperatureProbeUpperNonRecoverableThreshold 1 3 6 1 4 1 674 10892 1 700 20 1 9 Defines the value of the temperature probe s upper nonrecoverable threshold DellSigned32BitRange Read only Temperature Probe Upper Critical Threshold Name Object ID Description Syntax Access 1
33. DellString Read only Processor Device Stepping Name Name Object ID Description Syntax Access processorDeviceSteppingName 1 3 6 1 4 1 674 10892 1 1100 30 1 25 Defines the stepping of the processor device DellString Read only Processor Device Status Table Name Object ID Description Syntax Access 256 processorDeviceStatusTable 1 3 6 1 4 1 674 10892 1 1100 32 Defines the Processor Device Status Table SEQUENCE OF ProcessorDeviceStatusTableEntry Not accessible Device Group Processor Device Status Table Entry Name Object ID Description Syntax Access Index processorDeviceStatusTableEntry 1 3 6 1 4 1 674 10892 1 1100 32 1 Defines the Processor Device Status Table Entry ProcessorDeviceStatus TableEntry Not accessible processorDeviceStatusChassisIndex processorDeviceStatusIndex Processor Device Status Chassis Index Name Object ID Description Syntax Access processorDeviceStatusChassisIndex 1 3 6 1 4 1 674 10892 1 1100 32 1 1 Defines the index one based of the associated chassis DellObjectRange Read only Processor Device Status Index Name Object ID Description Syntax Access processorDeviceStatusIndex 1 3 6 1 4 1 674 10892 1 1100 32 1 2 Defines the index one based of the processor device status probe DellObjectRange Read only Device Group 257 Processor Device Status State Capabilities Name Object ID Description Syntax Access proce
34. Description Syntax Access bmcLANInterfaceMACAddress 1 3 6 1 4 1 674 10892 1 1900 30 1 12 Defines the MAC address of the BMC LAN interface DellMACAddress Read only Baseboard Management Controller Group 497 BMC LAN Interface Alert Community Name Name bmcLANInterfaceAlertCommunityName Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 13 Description Defines the SNMP community used for BMC LAN alerts traps sent on the BMC LAN interface Syntax DisplayString SIZE 0 32 Access Read only Baseboard Management Controller Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 21 1 BMC Serial Connection Mode Capabilities Variable Name De1 1BMCSerialConnectionModeCapabilities Data Type Integer These values are bit masks therefore combination values are possible Possible Data Values Meaning of Data Value none 0 No mode capabilities MC serial interface supports Modem modemBasic 1 B Basic mode B modemPPP 2 AC serial interface supports Modem Point to Point Protocol PPP mode modemTerminal 4 BMC serial interface supports Modem Terminal mode directBasic 8 BMC serial interface supports Direct Basic mode direct PPP 16 BMC serial interface supports Direct PPP mode directTerminal 32 BMC serial interface supports Direct Terminal mode 498 Baseboard Management Controller Group Table
35. Inventory Group 619 Device Group 0 4 620 Device Group Table 620 ApplicationGroup 622 Application Group Table 623 Operating System Group 625 Inventory Collector Product Information 626 ZO WAS ood otk ak lols ea Rb ea hg oe es 629 Trap Variables 0 630 SYS OM n s Shae a es Cow ae tok Bas Se 630 TableIndexOID 630 Message 0 2 02000005 630 Current Status yai sikiy ae he ew E 631 Previous Status 004 631 Dataset sd BES REE a on deh Ate 631 Understanding the Trap Description 632 Understanding Trap Severity 636 Instrumentation Traps 636 Miscellaneous Traps 636 Temperature Probe Traps 638 Cooling Device Traps 640 12 Contents Voltage Probe Traps 642 Amperage Probe Traps 644 Chassis Intrusion Traps 647 Redundancy Unit Traps 648 Power Supply Traps 650 Memory Device Traps 652 Fan Enclosure Traps 654 AC Power Cord Traps 655 Hardware LogTraps 656 Processor Device Status Traps 657 Pluggable Device Traps 658 BatteryTraps 200 660 RAG Traps eee 2 8 nt A ec ee a Sb 661 BMCTraps
36. Log Format Variable Name De1 1LogFormat Data Type Integer Possible Data Values Meaning of Data Value raw 1 ascii 2 uniCode 3 The log is in the format received from the firmware The log is in ASCII format The log is in Unicode format Table 5 2 Chassis Type Variable Name Del 1ChassisType Data Type Integer Possible Data Values other 1 unknown 2 desktop 3 lowProfileDesktop 4 pizzaBox 5 miniTower 6 tower 7 portable 8 lapTop 9 noteBook 10 handHeld 11 dockingStation 12 allInOne 13 100 Chassis Information Group Meaning of Data Value The chassis type is not one of the following The chassis type is unknown The chassis type is a desktop The chassis type is a low profile desktop The chassis type is a pizza box The chassis type is a minitower The chassis type is a tower The chassis type is a portable The chassis type is a laptop The chassis type is a notebook The chassis type is a handheld The chassis type is a docking station The chassis type is an all in one Table 5 2 Chassis Type continued Variable Name Del 1ChassisType Data Type Integer Possible Data Values Meaning of Data Value subNoteBook 14 spaceSaving 15 lunchBox 16 mainSystemChassis 17 expansionChassis 18 subChassis 19 busExpansionChassis 20 peripheralChassis 21 raidChassis 22 rackM
37. Meaning of Data Value systemSlotHotPlugCanSignal Attention 8 systemSlotHotPlugCanSignal PowerFault 16 systemSlotHotPlugCanSignal AdapterPresent 32 systemSlotHotPlugCanSignal PowerButtonPressed 64 canSupportAllHotPlugCapabi lities 126 systemSlotHotPlugIsUnknown 1 systemSlotCanProvide5Volts 128 systemSlotCanProvide3Point 3Volts 256 systemSlotCanSignalIfShared 512 systemSlotCanSupportCard16 1024 systemSlotCanSupportCardBus 2048 systemSlotCanSupport ZoomVid eo 4096 systemSlotCanSupportModem RingResume 8192 systemSlotCanSupport PMESig nal 16384 canSupportAllSlotCapabilit ies 32640 The system slot attention state and corresponding LED can be set Power on fault and corresponding LED can be detected due to a short or overcurrent Adapter card present in slot may not be powered can be detected The system slot power button can be pressed to signal a toggle of the power state The system slot can support all hot plug capabilities The system slot s capabilities are unknown The system slot can provide a 5 volt V supply The system slot can provide a 3 3 V supply The system slot s opening if shared with another slot can be detected The system slot can support PC Card 16 The system slot can support CardBus The system slot can support Zoom Video The system slot can support modem ring resume The system slot can su
38. Memory Device Type Details continued Variable Name De1 1MemoryDeviceTypeDetails Data Type Integer Possible Data Values Meaning of Data Value deviceTypeDetailIsEDO 9 The detailed device type is EDO deviceTypeDetailIsWindowDRAM 10 The detailed device type is Window DRAM deviceTypeDetailIsCacheDRAM 11 The detailed device type is Cache DRAM deviceTypeDetailIsNonVolatile 12 The detailed device type is nonvolatile Table 13 18 Generic Device Type Variable Name De1 1GenericDeviceType Data Type Integer Possible Data Values Meaning of Data Value deviceTypelIsOther 1 Device type is not one of the following deviceTypeIsUnknown 2 Device type is unknown deviceTypeIsAVideoDevice 3 Device type is a video deviceTypeIsASCSIController 4 Device type is a SCSI controller deviceTypeIsAnEthernetDevice 5 Device type is Ethernet deviceTypeIsTokenRingDevice 6 Device type is token ring deviceTypeIsASoundDevice 7 Device type is sound Device Group 307 Table 13 19 Memory Device Failure Modes Variable Name Del L MemoryDeviceFailureModes Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value 0 Memory device has no faults eccSingleBitCorrectionWarningRate 1 Memory device has exceeded the Correctable Memory Event warning rate eccSingleBitCorrectionFailureRate 2 Memory device
39. Name Object ID Description Syntax Access Status eventLogSeverityStatus 1 3 6 1 4 1 674 10892 1 300 40 1 7 Defines the severity of the event log record DellStatus Read only Mandatory Event Log Date Name Name Object ID Description Syntax Access Status event LogDateName 1 3 6 1 4 1 674 10892 1 300 40 1 8 Defines the date and time of the event log record DellDateName Read only Mandatory Chassis Information Group 83 System BIOS Table This table lists objects that define the system s basic input output system BIOS Name systemBlIOSTable Object ID 1 3 6 1 4 1 674 10892 1 300 50 Description Defines the System BIOS Table Syntax SEQUENCE OF SystemBIOSTableEntry Access Not accessible System BIOS Table Entry Name systemBlOSTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 Description Defines the System BIOS Table entry Syntax SystemBIOSTableEntry Access Not accessible Index systemBIOSchassisIndex systemBIOSIndex System BIOS Chassis Index Name systemBlOSchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only System BIOS Index Name systemBIOSIndex Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 2 Description Defines the index one based of the system BIOS of this object Syntax DellObjectRange Access Read only 84 Chassis Information Group System BIOS State Capabilit
40. Name remoteSNMPTrapFilterSysEventsMask Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 10 Description Defines the system events filter mask for this remote access SNMP trap destination Syntax DellUnsigned32BitRange Access Read write 454 Remote Access Group Remote SNMP Trap Filter DRS Capabilities Name remoteSNMPTrapFilterDrsCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 11 Description Defines the DRS events filter capabilities for this remote access SNMP trap destination Syntax DellUnsigned32BitRange Access Read only Remote SNMP Trap Filter System Capabilities Name remoteSNMPTrapFilterSysCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 12 Description Defines the system events filter capabilities of this remote access SNMP trap destination Syntax DellUnsigned32BitRange Access Read only Remote SNMP Trap Control Capabilities Name remoteSNMPTrapControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 13 Description Defines the control capabilities of this remote access SNMP trap destination Syntax DellRemoteSNMPTrapControlCapabilities See Table 19 20 Access Read only Remote SNMP Trap Control Settings Name remoteSNMPTrapControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 14 Description Defines the control settings of this remote access SNMP trap destination Syntax DellRemoteSNMPTrapControlSettings See Table 19 21 Access Read write Remote AccessGroup__ 455 Remote D
41. Object ID Description Syntax Access cooTroubleTicketState 1 3 6 1 4 1 674 10892 1 1600 110 1 3 Defines the trouble ticket information state for this system DellStateSettings Read only Cost of Ownership Group 423 COO Trouble Ticket Support Information Index Reference Name cooTroubleTicketSupport InformationIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1600 110 1 4 Description Defines the support information index that references the trouble ticket Syntax DellUnsigned32BitRange Access Read write COO Trouble Ticket Number Name Name cooTroubleTicketNumberName Object ID 1 3 6 1 4 1 674 10892 1 1600 110 1 5 Description Defines the trouble ticket number for this system Syntax DellCostofOwnershipString Access Read write Cost of Ownership Variable Values This section includes definitions for server administrator specific variable values used in this section Table 18 1 COO Ownership Codes Variable Name Del 1CooOwnershipCodes Data Type Integer Possible Data Values Meaning of Data Value other 1 he ownership code is not one of following m unknown 2 he ownership code is unknown owned 3 The ownership code is owned leased 4 The ownership code is leased rented 5 The ownership code is rented of fOfLease 6 he ownership code is off of lease transfer 7 he ownership code is transfer 424 Cost of Ownership Group Table 18 2 COO
42. Object ID Description Syntax Access physicalMemoryArrayMappedchassisIndex 1 3 6 1 4 1 674 10892 1 1300 20 1 1 Defines the index one based of this chassis DellObjectRange Read only Physical Memory Array Mapped Index Name Object ID Description Syntax Access physicalMemoryArrayMappediIndex 1 3 6 1 4 1 674 10892 1 1300 20 1 2 Defines the index one based of the memory array mapped address in this chassis DellObjectRange Read only Physical Memory Array Mapped State Capabilities Name Object ID Description Syntax Access physicalMemoryArrayMappedStateCapabilities 1 3 6 1 4 1 674 10892 1 1300 20 1 3 Defines the capabilities of the memory array mapped address DellStateCapabilities Read only Physical Memory Array Mapped State Settings Name Object ID Description Syntax Access physicalMemoryArrayMappedStateSettings 1 3 6 1 4 1 674 10892 1 1300 20 1 4 Defines the state of the memory array mapped address DellStateSettings Read write MemoryGroup__ 331 Physical Memory Array Mapped Status Name Object ID Description Syntax Access physicalMemoryArrayMappedStatus 1 3 6 1 4 1 674 10892 1 1300 20 1 5 Defines the status of the memory array mapped address DellStatus Read only Physical Memory Array Index Reference Name Object ID Description Syntax Access physicalMemoryArrayIndexReference 1 3 6 1 4 1 674 10892 1 1300 20 1 6 Defines the index to the associate
43. Occurred 670 Traps Table 25 19 BMC Traps continued TrapID Description Severity 2322178 ASR Automatic System Recovery Power Critical Down Occurred Critical 2322179 ASR Automatic System Recovery Power Cycle Occurred Traps 671 672 Traps Storage Management Alert Reference Storage Management s alert or event management features let you monitor the health of storage resources such as controllers connectors array disks and virtual disks Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging By default the Storage Management Service starts when the managed system starts up If you stop the Disk Management Service then alert monitoring and logging stops Alert monitoring does the following e Updates the status of the storage object that generated the alert e Propagates the storage object s status to all the related higher objects in the storage hierarchy For example the status of a lower level object will be propagated up to the status displayed on the Health tab for the top level storage object Logs an alert into the Alert log and Microsoft Windows application log e Sends an Simple Network Management Protocol SNMP trap if the operating system s SNMP service is installed and enabled K NOTE Storage Management does not log alerts regarding the data 1 0 path These alerts are logged by the respective RAID drivers in the system alert
44. Pointing Port Table Entry Name pointingPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 10 1 Description Defines the Pointing Port Table entry Syntax PointingPortTableEntry Access Not accessible Index pointingPortchassisIndex pointingPortIndex Pointing Port Chassis Index Name pointingPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Pointing Port Index Name pointingPort Index Object ID 1 3 6 1 4 1 674 10892 1 1000 10 1 2 Description Defines the index of the pointing ports in this chassis Syntax DellObjectRange Access Read only Pointing Port State Capabilities Name pointingPortStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1000 10 3 Description Defines the capabilities of the pointing port Syntax DellStateCapabilities Access Read only 210 Port Group Pointing Port State Settings Name Object ID Description Syntax Access pointingPortStateSettings 1 3 6 1 4 1 674 10892 1 1000 10 4 Defines the state and settings of the pointing port DellStateSettings Read write Pointing Port Status Name Object ID Description Syntax Access pointingPortStatus 1 3 6 1 4 1 674 10892 1 1000 10 5 Defines the status of the pointing port DellStatus Read only Pointing Port Security State Name Object ID Description Syntax Access pointingPortSecurityState 1 3 6 1 4 1 674 1
45. Power Group Power Supply Power Unit Index Reference Name Object ID Description Syntax Access powerSupplypowerUnit IndexReference 1 3 6 1 4 1 674 10892 1 600 12 1 10 Defines the index to the associated system power unit in this chassis DellObjectRange Read only Power Supply Sensor State Name Object ID Description Syntax Access powerSupplySensorState 1 3 6 1 4 1 674 10892 1 600 12 1 11 Defines the state reported by the power supply sensor and supplements the state and settings of the power supply DellPowerSupplySensorState See Table 8 4 Read only Power Supply Configuration Error Type Name Object ID Description Syntax Access powerSupplyConfigurationErrorType 1 3 6 1 4 1 674 10892 1 600 12 1 12 Defines the type of configuration error reported by the power supply sensor DellPowerSupplyConfigurationErrorType See Table 8 5 Read only Power Supply Power Monitor Capable Name Object ID Description Syntax Access powerSupplyPowerMonitorCapable 1 3 6 1 4 1 674 10892 1 600 12 1 13 Defines a boolean value that reports whether the power supply is capable of monitoring power consumption DellBoolean Read only Power Group 147 Voltage Probe Table Name voltageProbeTable Object ID 1 3 6 1 4 1 674 10892 1 600 20 Description Defines the Voltage Probe Table Syntax VoltageProbeTableEntry Access Not accessible Voltage Probe Table Entry Name voltagePr
46. Power Group 175 Table 8 8 Amperage Probe Definitions continued Variable Name De1 1AmperageType Data Type Integer Possible Data Values Meaning of Data Value amperageProbeTypeIsFLEA 11 The amperage probe type is a FLEA standby amperage probe amperageProbeTypelIsBattery 12 The amperage probe type is a battery amperage probe amperageProbeTypelIsTerminator 13 The amperage probe type is a Small Computer System Interface SCSI termination amperage probe amperageProbeTypels2Point5Volt 14 The amperage probe type is a 2 5 V amperage probe amperageProbeTypeIsGTL 15 The amperage probe type is a Gunning Transceiver Logic GTL probe amperageProbeTypelIsDiscrete 16 The amperage probe type is an amperage probe with discrete reading amperageProbeTypelIsPowerSupplyAmps 23 The amperage probe type is power supply probe with reading in Amperes amperageProbeTypeIsPowerSupplyWatts The amperage probe type is 24 power supply probe with reading in Watts amperageProbeTypelIsSystemAmps 25 The amperage probe type is system probe with reading in Amperes amperageProbeTypeIsSystemWatts 26 The amperage probe type is system probe with reading in Watts 176 Power Group Table 8 9 Amperage Probe Discrete Reading Variable Name DellAmperageDiscreteReading Data Type Integer Possible Data Values Meaning of Data Value amperageIsGood 1 The amperage probe discrete rea
47. Product ID Vendor Name product IDVendor Object ID 1 3 6 1 4 1 674 10899 100 3 Description Provides name of the manufacturer of the product Syntax DisplayString Access Read only Product ID Version Name Object ID Description Syntax Access product IDVersion 1 3 6 1 4 1 674 10899 100 4 Describes the version of the product DisplayString Read only Change Management Group _ 627 628 Product ID Build Number Name product IDBuildNumber Object ID 1 3 6 1 4 1 674 10899 100 5 Description Describes the software build number of the product Syntax DisplayString Access Read only Change Management Group Traps The Server Administrator generates events that result in Simple Network Management Protocol SNMP traps or operating system event logs Remote Access Controller RAC and Baseboard Management Controller BMC also can generate SNMP traps in response to hardware events This section describes the traps also known as alerts generated by the Server Administrator RAC and BMC The Server Administrator generates events in response to changes in the status of sensors and other monitored parameters When an event with predefined characteristics occurs on your system the SNMP subagent sends information about the event along with trap variables to the management console Each status change event generates a unique identifier called the trap ID and a trap description that describes the event The trap ID and
48. Read only Enclosure Management Module Vendor Name Object ID Description Syntax Access enclosureManagementModuleVendor 1 3 6 1 4 1 674 10893 1 20 130 13 1 3 Identifies the enclosure management module s re seller s name DisplayString Read only Storage Management Group 589 Enclosure Management Module State Name enclosureManagementModuleState Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 4 Description Identifies the current state of the enclosure management module Possible states 0 Unknown 1 Ready 2 Failed 3 Online 4 Offline 5 Not Installed 6 Degraded 21 Missing Syntax Integer Access Read only Enclosure Management Module Severity Name enclosureManagementModuleSeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 5 Description This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Syntax Integer Access Read only Enclosure Management Module Part Number Name enclosureManagementModulePartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 6 Description Identifies the part number of the enclosure memory module Syntax Display String Access Read only 590 Storage Management Group Enclosure Management Module Type Name Object ID Description Syntax Access enclosureManagementModuleType 1 3 6 1 4 1 674 10893 1 20 130 13 1 7 Identifies the type of the enclosure management module Possible values 0
49. Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellObjectRange Access Read only Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 2 Description Defines the index one based of the remote access hardware Syntax DellObjectRange Access Read only 434 Remote Access Group Remote Access Type Name remoteAccessType Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 3 Description Defines the type of remote access hardware Syntax DellRemoteAccess Type See Table 19 1 Access Read only Remote Access State Capabilities Name remoteAccessStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 4 Description Defines the state capabilities of the remote access hardware Syntax DellStateCapabilities Access Read only Remote Access State Settings Name remoteAccessStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 5 Description Defines the state setting of the remote access hardware Syntax DellStateSettings Access Read write Remote Access Status Name remoteAccessStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 6 Description Defines the status of the remote access hardware Syntax DellStatus Access Read only Remote Access Group __ 435 Remote Access Product Info Name Name remoteAccessP
50. Setup BIOS password state is unknown passwordControlEnabled 2 Setup BIOS has password changes enabled passwordControlJumperDisabled 4 Setup BIOS has determined that password control has been disabled by a jumper 378 BIOS Setup Control Group Table 16 9 BIOS Password Control Settings Variable Name De1 LBTOSPasswordControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown 1 Setup BIOS password state is unknown passwordControlEnabled 2 Setup BIOS has password changes enabled passwordControlJumperDisabled 4 Setup BIOS has determined that password control has been disabled by a jumper Table 16 10 TPM Security Control Capabilities Variable Name De1 1TPMSecurityControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value offCapable 1 TPM security can be Off onWithPrebootMeasurementsCap TPM security can be On with Pre boot able 2 Measurements onWithoutPrebootMeasurements TPM security can be On without Pre boot Capable 4 Measurements Table 16 11 TPM Security Control Setting Variable Name De1 1TPMSecurityControlSetting Data Type Integer Possible Data Values Meaning of Data Value off 0 TPM security is Off onWithPrebootMeasurements 1 TPM security is On with Pre boot Measurements onWithout PrebootMeasurements TPM security is On without Pre boot 2 Measurements
51. Storage Management Group 511 Agent Modifiers Name agentModifiers Object ID 1 3 6 1 4 1 674 10893 1 20 110 5 Description Identifies the agent functional modifiers When set the modifier is active Bit definitions Bit 3 agent in debug mode All other bits are product specific Syntax Integer Access Read only Agent Refresh Rate Name agentRefreshRate Object ID 1 3 6 1 4 1 674 10893 1 20 110 6 Description Identifies the rate given in seconds at which the cached data for SNMP is refreshed The default value is 300 seconds or 5 minutes Syntax Integer Access Read only Agent Hostname Name agentHostname Object ID 1 3 6 1 4 1 674 10893 1 20 110 7 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only 512 Storage Management Group Agent IP Address Name Object ID Description Syntax Access agentIPAddress 1 3 6 1 4 1 674 10893 1 20 110 8 This entry is obsolete for Storage Management DisplayString Read only Agent Software Status Name agentSoftwareStatus Object ID 1 3 6 1 4 1 674 10893 1 20 110 9 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only Agent SNMP Version Name agentSnmpVersion Object ID 1 3 6 1 4 1 674 10893 1 20 110 10 Description This entry is obsolete Refer to 0001 softwareVersion Syntax DisplayString Access Read only Agent MIB Version Name agentMibVersion Object ID 1 3 6 1 4
52. Table 1 2 describes each Server Administrator Instrumentation MIB group and lists the MIB group number assigned to the MIB group The Server Administrator Instrumentation MIB groups are identified by the SNMP OID 1 3 6 1 4 1 674 10892 1 lt MIB group number gt where lt MIB group number gt is the MIB group number assigned to the MIB group See the relevant section for more information about the MIB objects defined in a MIB group Table 1 2 Server Administrator Instrumentation MIB Sections in This Guide Section Topics MIB Group Numbers 2 Instrumentation MIB Version Group defines version 1 numbers of the Instrumentation MIB 3 Systems Management Software Group defines 100 information about the systems management software and the supported systems management standards 4 System State Group defines status state and 200 redundancy for a system and its components 18 Introduction Table 1 2 Server Administrator Instrumentation MIB Sections in This Guide continued Section Topics MIB Group Numbers 5 Chassis Information Group defines chassis types 300 events and indicators 6 Operating System Group defines variables for name 400 version service pack and other information about a system s operating system 7 System Resource Group defines variables for 500 input output ports memory interrupts and direct memory access 8 Power Group defines variables for power units power 600 suppl
53. Unknown 1 EMM 2 Termination Card Integer Read only Enclosure Management Module Firmware Version Name Object ID Description Syntax Access enclosureManagementModuleFWVersion 1 3 6 1 4 1 674 10893 1 20 130 13 1 8 Identifies the firmware version of the enclosure memory module DisplayString Read only Enclosure Management Module Maximum Speed Name Object ID Description Syntax Access enclosureManagementModuleMaxSpeed 1 3 6 1 4 1 674 10893 1 20 130 13 1 9 Identifies the maximum bus speed of the enclosure management module DisplayString Read only Storage Management Group 591 Enclosure Management Module Roll Up Status Name enclosureManagementModuleRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 10 Description Severity of the enclosure management module state This is the combined status of the EMM and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Enclosure Management Module Component Status Name enclosureManagementModuleComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 11 Description The status of the enclosure management module itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 592 Storage Management Gr
54. and so on OCTET STRING SIZE 1 128 Read only System State Group 53 System State Memory Device State Details Name Object ID Description Syntax Access systemStateMemoryDeviceStateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 26 Defines the state of all memory devices in this chassis The results are returned as a binary octet string Each byte of the octet string represents the state of the specific memory device The first byte returned represents the state of the first memory device the second byte returned represents the status of the second memory device and so on The bytes have the same definition type as DellStateSettings OCTET STRING SIZE 1 128 Read only System State Memory Device Status Combined Name Object ID Description Syntax Access systemStateMemoryDeviceStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 27 Defines the status of all memory devices in this chassis DellStatus Read only System State Memory Device Status Details Name Object ID Description Syntax Access 54 systemStateMemoryDeviceStatusDetails 1 3 6 1 4 1 674 10892 1 200 10 1 28 Defines the status of all memory devices in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific memory device The first byte returned represents the status of the first memory device the second byte returned represents the status of the second memory
55. currentStatusEvent e previousStatusEvent Viewing SNMP Traps SNMP traps that are generated by Storage Management can be viewed in any standard SNMP compatible enterprise management console These traps are defined in the Storage Management MIB These traps correspond to the alerts documented in the Alert Descriptions and Corrective Actions section For more information on the MIB and its structure as well as a change history of the SNMP traps see the Introduction section For more information on configuring SNMP see SNMP Support for Storage Management Alerts Alert Descriptions and Corrective Actions The alerts generated by the redundant array of independent disks RAID or Small Computer System Interface SCSI controllers and supported by Storage Management are displayed in the Server Administrator Alert subtab or through Windows Event Viewer These alerts can also be forwarded as SNMP traps to other applications SNMP traps that are generated for the alerts are included in the Storage Management MIB The SNMP traps for these alerts use all of the SNMP trap variables For the list of storage management alerts and storage management messages see the Dell OpenManage Server Administrator Messages Reference Guide This guide is available on the Dell Support website at support dell com and on the Dell Systems Management Tools and Documentation DVD 676 Storage Management Alert Reference Standard Data Type Definitions Th
56. destination Syntax DellRemoteSNMPTrapStateCapabilities See Table 19 18 Access Read only Remote SNMP Trap State Settings Name remoteSNMPTrapStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 5 Description Defines the state settings of this remote access SNMP trap destination Syntax DellRemoteSNMPTrapStateSettings See Table 19 19 Access Read write Remote SNMP Trap Status Name remoteSNMPTrapStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 6 Description Defines the status of this remote access SNMP trap destination Syntax DellStatus Access Read only Remote AccessGroup__ 453 Remote SNMP Trap Destination IP Address Name remoteSNMPTrapDestinationIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 7 Description Defines the IP address of this remote access SNMP trap destination Syntax IpAddress Access Read write Remote SNMP Trap SNMP Community Name Name remoteSNMPTrapSNMPCommunityName Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 8 Description Defines the community for traps sent to this remote access SNMP trap destination Syntax DisplayString SIZE 0 31 Access Read write Remote SNMP Trap Filter DRS Events Mask Name remoteSNMPTrapFilterDrsEventsMask Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 9 Description Defines the DRS events filter mask for this remote access SNMP trap destination Syntax DellUnsigned32BitRange Access Read write Remote SNMP Trap Filter System Events Mask
57. device and so on The bytes have the same definition type as DellStatus OCTET STRING SIZE 1 128 Read only System State Group System State Chassis Intrusion State Details Name Object ID Description Syntax Access systemStateChassisIntrusionStateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 29 Defines the intrusion state of all intrusion detection devices in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific intrusion detection device The first byte returned represents the status of the first intrusion detection device the second byte returned represents the status of the second intrusion detection device and so on The bytes have the same definition type as DellStateSettings OCTET STRING SIZE 1 128 Read only System State Chassis Intrusion Status Combined Name Object ID Description Syntax Access systemStateChassisIntrusionStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 30 Defines the intrusion status of all intrusion detection devices in this chassis The result is returned as a combined status value The value has the same definition type as DellStatus DellStatus Read only System State Chassis Intrusion Status Details Name Object ID Description Syntax Access systemStateChassisIntrusionStatusDetails 1 3 6 1 4 1 674 10892 1 200 10 1 31 Defines the intrusion status of all intrusion detection dev
58. deviceFamilyIs80386 5 deviceFamilyIs80486 6 deviceFamily1IS8087 7 deviceFamilyIs80287 8 deviceFamilyIs80387 9 deviceFamilyIs80487 10 deviceFamilyIsPentium 11 deviceFamilyIsPentiumPro 12 The processor family is not one of the following values The processor family is unknown The processor family is 8086 The processor family is 80286 The processor family is 80386 The processor family is 80486 The processor family is 8087 The processor family is 80287 The processor family is 80387 The processor family is 80487 The processor family is Intel Pentium The processor family is Pentium Pro Device Group 295 Table 13 6 Processor Device Family continued Variable Name De1 1 ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsPentium2 13 The processor family is Pentium II deviceFamilyIsPentiumMMXx 14 The processor family is Pentium MMxX deviceFamilyIsCeleron 15 The processor family is Celeron deviceFamilyIsXeon 16 The processor family is Xeon deviceFamilyIsPentium3 17 The processor family is Pentium III deviceFamilyIsPentium3Xeon 18 The processor family is Pentium II Xeon deviceFamilyIsPentium3Step 19 The processor family is Pentium III Speed Step deviceFamilyIsPentiumItanium The processor family is Itanium 20 deviceFamilyIsIntelXeon 21 The processor family is Intel Xeon deviceFamilyI
59. function NIF Wakeup on LAN Syntax DellNIFwakeonLanControlCapabilitiesUnique SeeTable 16 4 Access Read only BIOS Setup Control NIF Wakeup on LAN Control Settings Unique Name bSUCnIFwakeonLanControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 19 Description Defines the state of the NIF Wakeup on LAN Syntax DelINIFwakeonLanControlSettingsUnique See Table 16 4 Access Read only 354 BIOS Setup Control Group BIOS Setup Control NIF Wakeup on LAN Control Status Name bsuUCnIFwakeonLanControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 20 Description Defines the status of the NIF Wakeup on LAN Syntax DellStatus Access Read only BIOS Setup Control NIF Wakeup on LAN Control Name Name bsSUCnIFwakeonLanControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 21 Description Defines the setup BIOS name of the NIF Wakeup on LAN Syntax DellString Access Read only BIOS Setup Control Boot Sequence Control Capabilities Unique Name bSUCboot SequenceControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 22 Description Defines the capabilities of the boot sequence Syntax DellBootSequenceControlCapabilitiesUnique SeeTable 16 5 Access Read only BIOS Setup Control Boot Sequence Control Settings Unique Name Del1lBootSequenceControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 23 Description Defines the state of the boot sequence Syntax DellBootSequenceControlSettingsUniqu
60. host system control action Action requested was lt Action gt Information Information Server Administrator completed its initialization This message is generated when a system is configured for thermal shutdown due to an error event If a temperature sensor reading exceeds the error threshold for which the system is configured the operating system shuts down and the system powers off This event may also be initiated on certain systems when a fan enclosure is removed from the system for an extended period of time This message is generated when an automatic system recovery action is performed due to a hung operating system The action performed and the date and time of the action are provided User requested a host system control action to reboot power off or power cycle the system or another event such as thermal shutdown protection initiated a power off operating system shutdown Traps 637 Temperature Probe Traps Temperature probes help protect critical components by alerting the systems management console when temperatures become too high inside a chassis The temperature probe traps use additional variables sensor location chassis location previous state and temperature sensor value reported in degrees Celsius Table 25 3 Temperature Probe Traps Trap ID Description Severity Cause Temperature Probe Normal 1052 Temperature sensor returned Information A temperature sensor to a normal
61. voltage probes System State Group Table The System State Group defines objects in the System State MIB table System State Table The following object sets up the System State Table Name systemStateTable Object ID 1 3 6 1 4 1 674 10892 1 200 10 Description Defines the System State Table Syntax SEQUENCE OF SystemStateTableEntry Access Not accessible System State Table Entry Name systemStateTableEntry Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 Description Defines the System State Table entry Syntax SystemStateTableEntry Access Not accessible Index systemStatechassisIndex System State Group 45 System State Chassis Index Name systemStatechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only System State Global System Status Name systemStateGlobalSystemStatus Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 2 Description Defines the global system status of all chassis being monitored by this instrumentation instance Syntax DellStatus Access Read only System State Chassis State Name systemStateChassisState Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 3 Description Defines the system state of this chassis Syntax DellStateSettings Access Read only System State Chassis Status Name systemStateChassisStatus Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 4 Description Defines the system status of this chass
62. 1 3 6 1 4 1 674 10892 1 1300 60 Defines the Physical Memory Card Table SEQUENCE OF PhysicalMemoryCardTableEntry Not accessible Physical Memory Card Table Entry Access Name Object ID Description Syntax Index physicalMemoryCardTableEntry 1 3 6 1 4 1 674 10892 1 1300 60 1 Defines the Physical Memory Card Table Entry PhysicalMemoryCard TableEntry Not accessible physicalMemoryCardChassisIndex physicalMemoryCardIndex Physical Memory Card Chassis Index Name Object ID Description Syntax Access 340 physicalMemoryCardChassisIndex 1 3 6 1 4 1 674 10892 1 1300 60 1 1 Defines the index one based of the associated chassis DellObjectRange Read only Memory Group Physical Memory Card Index Name Object ID Description Syntax Access physicalMemoryCardIndex 1 3 6 1 4 1 674 10892 1 1300 60 1 2 Defines the index one based of the Physical Memory Card DellObjectRange Read only Physical Memory Card State Capabilities Name Object ID Description Syntax Access physicalMemoryCardStateCapabilities 1 3 6 1 4 1 674 10892 1 1300 60 1 3 Defines the state capabilities of the Physical Memory Card DellStateCapabilities Read only Physical Memory Card State Settings Name Object ID Description Syntax Access physicalMemoryCardStateSettings 1 3 6 1 4 1 674 10892 1 1300 60 1 4 Defines the state settings of the Physical Memory Card DellStateSettings Read write Physical Memory
63. 1 4 1 674 10892 1 1000 90 1 6 Description Syntax Access Defines the security settings of the USB port DellPortSecurityState Read only PortGroup 235 USB Port Connector Type Name uSBPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 7 Description Defines the connector type of the USB port Syntax DellUSBPortConnector Type Access Read only USB Port Name Name uSBPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 8 Description Defines the name of the USB port Syntax DellString Access Read only USB Port BIOS Connector Type Name uSBPortBIOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 9 Description Defines the BIOS connector type of the USB port Syntax DellGenericPortConnectorlype Access Read only 236 Port Group Port Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 12 1 Pointing Port Connector Type Variable Name De11PointingPortConnectorType Data Type Integer Possible Data Values Meaning of Data Value connectorPortTypelIsOther 1 The pointing port connector type is not one of the following connectorPortTypelIsUnknown 2 The pointing port connector type is unknown connectorPortTypelIsSerial 3 The pointing port connector type is serial connectorPortTypelIsPS2 4 The pointing port connector type is a Personal System 2 PS 2 connectorPortTypeIsiInfrared 5 The
64. 1 500 30 1 9 Defines the 64 bits of the ending address of the system resource TVO port DellUnsigned64BitRange Read only System Resource Memory Table Name Object ID Description Syntax Access systemResourceMemoryTable 1 3 6 1 4 1 674 10892 1 500 40 Defines the System Resource Memory Table SEQUENCE OF SystemResourceMemory TableEntry Not accessible System Resource Memory Table Entry Name Object ID Description Syntax Access Index systemResourceMemoryTableEntry 1 3 6 1 4 1 674 10892 1 500 40 1 Defines the System Resource Memory Table entry SystemResourceMemory TableEntry Not accessible systemResourceMemorychassisIndex systemResourceMemoryIndex System Resource Memory Chassis Index Name Object ID Description Syntax Access systemResourceMemorychassisIndex 1 3 6 1 4 1 674 10892 1 500 40 1 1 Defines the index one based of this chassis DellObjectRange Read only System Resource Group 127 System Resource Memory Index Name systemResourceMemoryIndex Object ID 1 3 6 1 4 1 674 10892 1 500 40 1 2 Description Defines the index of system resource memory in this chassis Syntax DellObjectRange Access Read only System Resource Memory State Capabilities Name systemResourceMemoryStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 500 40 1 3 Description Defines the capabilities of this system resource memory Syntax DellObjectRange Access Read only System Resource Memory State
65. 1 674 10893 1 20 110 11 Description Identifies the version of the Storage Management MIB Syntax DisplayString Access Read only Storage Management Group 513 Agent Management Software URL Name Name agentManagement SoftwareURLName Object ID 1 3 6 1 4 1 674 10893 1 20 110 12 Description Identifies the Universal Resource Locator URL of the systems management software Syntax DisplayString Access Read only Agent Global System Status Name agentGlobalSystemStatus Object ID 1 3 6 1 4 1 674 10893 1 20 110 13 Description Global health information for the subsystem managed by the Storage Management software This global status should be used by applications other than HP OpenView HP OpenView should refer to the globalStatus in the root level object group This is a rollup for the entire agent including any monitored devices The status is intended to give initiative to an SNMP monitor to get further data when this status is abnormal Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 514 Storage Management Group Agent Last Global System Status Name Object ID Description Syntax Access agentLastGlobalSystemStatus 1 3 6 1 4 1 674 10893 1 20 110 14 The previous global status of the system managed by the Storage Management software Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recover
66. 10 Defines the bus speed in MHz of the PCI device in this chassis A zero 0 indicates that the speed is unknown Syntax DellUnsigned32BitRange Access Read only PCI Device Adapter Fault Name pCIDeviceAdapterFault Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 11 Description Defines whether the PCI device in this chassis has detected a fault Syntax DellBoolean Access Read only PCI Device Configuration Space Table Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceTable 1 3 6 1 4 1 674 10892 1 1100 82 Defines the PCI Device Configuration Table SEQUENCE OF PCIDeviceConfigurationSpaceTableEntry Not accessible PCI Device Configuration Space Table Entry Name Object ID Description Syntax Access Index pCIDeviceConfigurationSpaceTableEntry 1 3 6 1 4 1 674 10892 1 1100 82 1 Defines the PCI Device Configuration Table entry PC DeviceConfigurationS pace TableEntry Not accessible pCIDeviceConfigurationSpacechassisIndex pClDeviceConfigurationSpaceIndex Device Group 281 PCI Device Configuration Space Chassis Index Name Object ID Description Syntax Access pCIDeviceConfigurationSpacechassisIndex 1 3 6 1 4 1 674 10892 1 1100 82 1 1 Defines the index one based of this chassis DellObjectRange Read only PCI Device Configuration Space Index Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceIndex 1 3 6 1 4 1 674 10892 1 1100 82 1 2 Defines
67. 10892 1 1300 50 1 3 Defines the state capabilities of the redundant memory unit DellStateCapabilities Read only Memory Group Redundant Memory Unit State Settings Name Object ID Description Syntax Access redundantMemoryUnitStatesettings 1 3 6 1 4 1 674 10892 1 1300 50 1 4 Defines the state settings of the redundant memory unit DellStateSettings Read write Redundant Memory Unit Redundancy Status Name Object ID Description Syntax Access redundantMemoryUnitRedundancyStatus 1 3 6 1 4 1 674 10892 1 1300 50 1 5 Defines the redundancy status of the redundant memory unit DellStatusRedundancy Read only Redundant Memory Unit Name Name Object ID Description Syntax Access redundantMemoryUnitName 1 3 6 1 4 1 674 10892 1 1300 50 1 6 Defines the name of the redundant memory unit DellString Read only Redundant Memory Unit Status Name Object ID Description Syntax Access redundantMemoryUnitStatus 1 3 6 1 4 1 674 10892 1 1300 50 1 7 Defines the status of the redundant memory unit DellStatus Read only MemoryGroup__ 339 Physical Memory Card Table This table defines the name of the memory card the total number of device slots present on the memory card and the number of memory device slots in use on the memory card The following objects set up the Physical Memory Card Table Physical Memory Card Table Name Object ID Description Syntax Access physicalMemoryCardTable
68. 130 9 1 4 Description Identifies the current state of the power supply Possible states 0 Unknown 1 Ready 2 Failed 5 Not Installed 6 Degraded 11 Removed Syntax Integer Access Read only Power Supply Severity Name powerSupplySeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 5 Description This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Syntax Integer Access Read only Power Supply 1 Part Number Name powerSupply1PartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 6 Description Identifies the part number of the power supply of the enclosure Syntax DisplayString Access Read only 576 Storage Management Group Power Supply 2 Part Number Name powerSupply2PartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 7 Description This entry is obsolete This setting is not supported by power supplies managed under Storage Management Syntax DisplayString Access Read only Power Supply Roll Up Status Name powerSupplyRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 8 Description Severity of the power supply state This is the combined status of the power supply and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Storage Management Group 577 Power Supply Component Status Name powerSupplyComponent Status Object ID
69. 14 The memory array location is a Personal Computer Memory Card International Association PCMCIA option card The memory array location is a proprietary option card The memory array location is a NuBus bus The memory array location is a PC 98 C20 option card The memory array location is a PC 98 C24 option card The memory array location is a PC 98 E option card The memory array location is a PC 98 Local bus option card memoryArrayLocationIsPC98Card 15 The memory array location is a PC 98 Card slot option card 344 Memory Group Table 15 2 Physical Memory Array ECC Type Definitions Variable Name De11PhysicalMemoryArrayECCType Data Type Integer Possible Data Values Meaning of Data Value memoryArrayECCTypelIsOther 1 There is not one of the following memoryArrayECCTypelIsUnknown 2 The memory array ECC type is unknown memoryArrayECCTypelsNone 3 The memory array ECC type is none memoryArrayECCTypelsParity 4 The memory array ECC type is parity memoryArrayECCTypelIsSingleBitECC 5 The memory array ECC type is Correctable Memory Event ECC memoryArrayECCTypeIsMultiBitECC 6 The memory array ECC type is memoryArrayECCTypeIsCRC 7 Uncorrectable Memory Event ECC The memory array ECC type is CRC Table 15 3 Physical Memory Configuration State Capabilities Variable Name De11PhysicalMemoryConfigStateCapabilities Data Type Integer
70. 3 6 1 4 1 674 10892 1 1400 10 1 38 Defines the BIOS setup control status of Trusted Platform Module TPM security DellStatus Read only BIOS Setup Control TPM Security Control Name Name Object ID Description Syntax Access bsuCtpmSecurityControlName 1 3 6 1 4 1 674 10892 1 1400 10 1 39 Defines the BIOS setup control name of Trusted Platform Module TPM security DellString Read only BIOS Setup Control Group 359 SCSI Control Table Name sCSIControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 20 Description Defines the Small Computer System Interface SCSI Control Table Syntax SCSIControlTableEntry Access Not accessible SCSI Control Table Entry Name sCSIControlTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 Description Defines the SCSI Control Table entry Syntax SCSIControlTableEntry Access Not accessible Index sCSIControlchassisIndex sCSIControllndex SCSI Control Chassis Index Name sCSIControlchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only SCSI Control Index Name sCSIControlIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 2 Description Defines the index one based of the SCSI controller in this chassis Syntax DellObjectRange Access Read only 360 BIOS Setup Control Group SCSI Control Capabilities Name sCSIControlCapabilities Object ID 1 3 6 1 4
71. 3 6 1 4 1 674 10892 1 600 60 1 7 Defines the total wattage used in Watt hours by this entity since the date and time specified by the powerUsageCumulative WattageStartDateName attribute DellUnsigned32BitRange Read only Power Group 167 Power Usage Cumulative Wattage Start Date Name Name Object ID Description Syntax Access powerUsageCumulativeWattageStartDateName 1 3 6 1 4 1 674 10892 1 600 60 1 8 Defines the date and time at which the data collection started for the value reported by the powerUsageCumulative Wattage attribute DellDateName Read only Power Usage Peak Watts Name Object ID Description Syntax Access powerUsagePeakWatts 1 3 6 1 4 1 674 10892 1 600 60 1 9 Defines the peak wattage reading in Watts for this entity since the date and time specified by the powerUsagePeakWattsStartDateName attribute DellUnsigned32BitRange Read only Power Usage Peak Watts Start Date Name Name Object ID Description Syntax Access powerUsagePeakWattsStartDateName 1 3 6 1 4 1 674 10892 1 600 60 1 10 Defines the date and time at which the data collection started for the value reported by the powerUsagePeakWatts attribute DellDateName Read only 168 Power Group Power Usage Peak Watts Reading Date Name Name Object ID Description Syntax Access powerUsagePeakWatt sReadingDat eName 1 3 6 1 4 1 674 10892 1 600 60 1 11 Defines the date and time at which the valu
72. 30 1 4 Defines the state settings of the physical memory configuration DellPhysicalMemoryConfigStateSettings Read write Memory Group Physical Memory Configuration Status Name Object ID Description Syntax Access physicalMemoryConfigStatus 1 3 6 1 4 1 674 10892 1 1300 30 1 5 Defines the status of the physical memory configuration DellStatus Read only Physical Memory Configuration Redundant Capabilities Name Object ID Description Syntax Access physicalMemoryConfigRedundantCapabilities 1 3 6 1 4 1 674 10892 1 1300 30 1 6 Defines the redundant capabilities of the physical memory DellPhysicalMemoryConfigRedundantCapabilities Read only Physical Memory Configuration Redundant Settings Name Object ID Description Syntax Access physicalMemoryConfigRedundantSettings 1 3 6 1 4 1 674 10892 1 1300 30 1 7 Defines the redundant settings of the physical memory DellPhysicalMemoryConfigRedundantSettings Read write Physical Memory Logging Table This table defines the conditions for logging system memory events The following object sets up the Physical Memory Logging Table Name Object ID Description Syntax Access physicalMemoryLoggingTable 1 3 6 1 4 1 674 10892 1 1300 40 Defines the Physical Memory Logging Table SEQUENCE OF PhysicalMemoryLogging TableEntry Not accessible MemoryGroup__ 335 Physical Memory Logging Table Entry Name Object ID Description Syntax Access Inde
73. 6 1 4 1 674 10893 1 20 130 4 1 9 Description Identifies the SCSI ID of the enclosure processor to which this array disk belongs Syntax DisplayString Access Read only Array Disk Channel Name arrayDiskChannel Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 10 Description Identifies the bus to which this array disk is connected Syntax Integer Access Read only Array Disk Length in Megabytes Name arrayDiskLengthInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 11 Description Identifies the size in megabytes of the array disk If this size is 0 it is smaller than a megabyte Syntax Integer Access Read only Array Disk Length in Bytes Name arrayDiskLengthInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 12 Description Identifies the size of the array disk in bytes that is less than a megabyte This size plus the arrayDiskLengthInMB is the total size of the array disk Syntax Integer Access Read only Storage Management Group 553 Array Disk Largest Contiguous Free Space in Megabytes Name arrayDiskLargestContiguousFreeSpaceInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 13 Description The size in megabytes of the largest contiguous free space on the array disk If this size is 0 it is less than a megabyte Syntax Integer Access Read only Array Disk Largest Contiguous Free Space in Bytes Name arrayDiskLargestContiguousFreeSpaceInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 14 Description
74. 674 10893 1 20 130 7 1 1 Identifies the instance number of the fan entry Integer Read only Fan Name 1 3 6 1 4 1 674 10893 1 20 130 7 1 2 Identifies the fan s name as represented in Storage Management DisplayString Read only fanVendor 1 3 6 1 4 1 674 10893 1 20 130 7 1 3 Identifies the fan s re seller s name DisplayString Read only Storage Management Group 567 Fan State Name fanState Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 4 Description Identifies the current state of the fan Possible states 0 Unknown 1 Ready 2 Failed 3 Online 4 Offline 6 Degraded 21 Missing Syntax Integer Access Read only Fan Severity Name fanSeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 5 Description This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Syntax Integer Access Read only Fan Probe Unit Name fanProbeUnit Object ID 1 3 6 1 4 1 674 10893 1 20 130 7 1 6 Description This entry is obsolete for Storage Services Syntax DisplayString Access Read only 568 Storage Management Group Fan Probe Minimum Warning Name Object ID Description Syntax Access fanProbeMinimumWarning 1 3 6 1 4 1 674 10893 1 20 130 7 1 7 This entry is obsolete This setting is not supported by fans managed under Storage Management DisplayString Read only Fan Probe Minimum Critical Name Object ID Description Syntax Access
75. 7 Description Defines the serial number of the FRU Syntax DisplayString SIZE 0 64 Access Read only FRU Part Number Name Name fruPartNumberName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 8 Description Defines the part number of the FRU Syntax DisplayString SIZE 0 64 Access Read only Field Replaceable Unit Group 503 FRU Revision Name Name fruRevisionName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 9 Description Defines the revision of the FRU Syntax DisplayString SIZE 0 64 Access Read only FRU Manufacturing Date Name Name fruManufacturingDateName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 10 Description Defines the manufacturing date of the FRU Syntax DellDateName Access Read only FRU Asset Tag Name Name fruAssetTagName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 11 Description Defines the asset tag of the FRU Syntax DisplayString SIZE 0 64 Access Read only 504 Field Replaceable Unit Group FRU Group Variable Values This section includes definitions for server administrator specific variable P values Table 22 1 FRU Information State Variable Name De11FRUInformationState Data Type Integer Possible Data Values Meaning of Data Value ok 1 notSupported 2 notAvailable 3 checksumInvalid 4 corrupted 5 FRU information is okay FRU information is not supported FRU information is not available FRU information checksum is invalid FRU inform
76. 712 Glossary RAW Unprocessed The term refers to data that is passed along to an I O device without being interpreted In contrast cooked refers to data that is processed before being passed to the I O device It often refers to uncompressed text that is not stored in any proprietary format The term comes from UNIX which supports cooked and raw modes for data output to a terminal RDRAM Acronym for Rambus DRAM A dynamic RAM chip technology from Rambus Inc Direct RDRAMs are used in computers Direct RDRAM chips are housed in RIMM modules which are similar to DIMMs but have different pin settings The chips can be built with dual channels doubling the transfer rate to 3 2 GB sec read only file A read only file is one that you are prohibited from editing or deleting A file can have read only status if Its read only attribute is enabled It resides on a physically write protected diskette or on a diskette in a write protected drive It is located on a network in a directory to which the system administrator has assigned read only rights to you readme file A text file included with a software package or hardware product that contains information supplementing or updating the documentation for the software or hardware Typically readme files provide installation information describe new product enhancements or corrections that have not yet been documented and list known problems or other things you need to be aware of
77. 731 732 Index
78. 8 1 5 Description Identifies the instance number of the enclosure in the enclosureTable to which this fan belongs Syntax Integer Access Read only Power Supply Table This table describes available properties for each power supply on the managed system The following object sets up the Power Supply Table Name powerSupplyTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 Description Defines the power supply table Syntax SEQUENCE OF PowerSupplyEntry Access Not accessible 574 Storage Management Group Power Supply Entry Name powerSupplyEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 Description Defines the power supply table entry Syntax PowerSupplyEntry Access Not accessible Index powerSupplyNumber Power Supply Number Name powerSupplyNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 1 Description Identifies the instance number of the power supply entry Syntax Integer Access Read only Power Supply Name Name powerSupplyName Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 2 Description Identifies the power supply s name as represented in Storage Management Syntax DisplayString Access Read only Power Supply Vendor Name powerSupplyVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 3 Description Identifies the power supply s re seller s name Syntax DisplayString Access Read only Storage Management Group 575 Power Supply State Name powerSupplyState Object ID 1 3 6 1 4 1 674 10893 1 20
79. Access NIC Current Information From Dynamic Host Configuration Protocol DHCP Name remoteAccessNICCurrent InfoFromDHCP Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware Syntax DellBoolean Access Read only Remote Access Remote Connect URL Name remoteAccessRemoteConnectURL Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 34 Description Defines the URL for launching the Remote Access Remote Connect Interface Syntax DisplayString SIZE 0 63 Access Mandatory DRAC Ill On systems with DRAC III the Remote Access Group includes the following MIB tables Remote Access Table Remote User Administration Table Remote SNMP Trap Table Remote Dial Up Table Remote User Dial In Configuration Table Remote Dial Out Table Remote Access Group 433 Remote Access Table The following MIB object sets up the Remote Access Table Name remoteAccessTable Object ID 1 3 6 1 4 1 674 10892 1 1700 10 Description Defines the Remote Access Table Syntax SEQUENCE OF RemoteAccessTableEntry Access Not accessible Remote Access Table Entry Name remoteAccessTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 Description Defines the Remote Access Table entry Syntax RemoteAccessTableEntry Access Not accessible Index remoteAccessChassisIndex remoteAccessAdapterIndex
80. Access Read only Virtual Disk Component Status Name virtualDiskComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 20 Description The status of the virtual disk itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 612 Storage Management Group Virtual Disk Nexus ID Name virtualDiskNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 21 Description Durable unique ID for this virtual disk Syntax DisplayString Access Read only Virtual Disk Array Disk Type Name virtualDiskArrayDiskType Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 22 Description Identifies the type of array physical disks used to create the virtual disk Possible values 1 SAS 2 SATA 3 SCSI 4 IDE 99 Unknown Syntax Integer Access Read only Array Disk Logical Connection Table This table describes the connections between array disks the virtual disk to which they belong and their associated logical disk For each object in the table its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found The following object sets up the Array Disk Logical Connection Table Storage Management Group 613 Name arrayDiskLogicalConnectionTable Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 Description Defin
81. Card Status Name Object ID Description Syntax Access physicalMemoryCardStatus 1 3 6 1 4 1 674 10892 1 1300 60 1 5 Defines the status of the Physical Memory Card DellStatus Read only MemoryGroup__ 341 Physical Memory Card Name Access Name Object ID Description Syntax physicalMemoryCardName 1 3 6 1 4 1 674 10892 1 1300 60 1 6 Defines the name of the Physical Memory Card DellString Read only Physical Memory Card Total Number Sockets Access Name Object ID Description Syntax physicalMemoryCardTotalNumberSockets 1 3 6 1 4 1 674 10892 1 1300 60 1 7 Defines the total number of memory sockets available on the Physical Memory Card 2 147 483 647 indicates an unknown number of sockets DellUnsigned32BitRange Read only Physical Memory Card In Use Number Sockets Name Object ID Description Syntax Access 342 physicalMemoryCardInUseNumberSockets 1 3 6 1 4 1 674 10892 1 1300 60 1 8 Defines the number of memory sockets in use on the Physical Memory Card Zero indicates that the Physical Memory Card is not installed or has a configuration error DellUnsigned32BitRange Read only Memory Group Physical Memory Card Physical Memory Array Index Reference Name Object ID Description Syntax Access Memory Group Variable Values physicalMemoryCardPhyMemArrayIndexReference 1 3 6 1 4 1 674 10892 1 1300 60 1 9 Defines the index one based of the Physical Memory Arr
82. Defines the array disk table entry Syntax ArrayDiskEntry Access Not accessible Index array DiskNumber Array Disk Number Name arrayDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 1 Description Identifies the instance number of the array disk entry Syntax Integer Access Read only Storage Management Group 549 Array Disk Name Name arrayDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 2 Description Identifies the name of the array disk as represented in Storage Management Syntax DisplayString Access Read only Array Disk Vendor Name arrayDiskVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 3 Description The array disk s manufacturer s name Syntax DisplayString Access Read only 550 Storage Management Group Array Disk State Name Object ID Description Syntax Access arrayDiskState 1 3 6 1 4 1 674 10893 1 20 130 4 1 4 Identifies the current state of the array disk Possible states 0 Unknown 1 Ready Available for use but no RAID configuration has been assigned 2 Failed Not operational 3 Online Operational RAID configuration has been assigned 4 Offline The drive is not available to the RAID controller 6 Degraded Refers to a fault tolerant array virtual disk that has a failed disk 7 Recovering Refers to state of recovering from bad blocks on disks 11 Removed Indicates that array disk has been removed 15 Resynching Indicates one of the following types
83. Defines the file name of the operating system image obtained from the TFTP server used by the remote access hardware Syntax DisplayString SIZE 0 255 Access Read write Remote Access Group 439 Remote Access Firmware Update IP Address Name remoteAccessFirmwareUpdateIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 23 Description Defines the IP address of the update server providing the firmware image used by the remote access hardware Syntax IpAddress Access Read write Remote Access Firmware Update Path Name Name remoteAccessFirmwareUpdatePathName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 24 Description Defines the file name of the firmware image obtained from the update server used by the remote access hardware Syntax DisplayString SIZE 0 255 Access Read write Remote Access Network Interface Controller NIC Static IP Address Name remoteAccessNICStaticIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 25 Description Defines the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read write Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read write 440 Remote Access Group Remote
84. Defines the index one based of the associated BMC Syntax DellObjectRange Access Read only Baseboard Management Controller Group 491 BMC Serial Interface Index Name bmcSerialInterfaceIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 3 Description Defines the index one based of the BMC serial interface Syntax DellObjectRange Access Read only BMC Serial Interface State Capabilities Name bmcSerialInterfaceStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 4 Description Defines the state capabilities of the BMC serial interface Syntax DellStateCapabilities Access Read only BMC Serial Interface State Settings Name bmcSerialInterfaceStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 5 Description Defines the state settings of the BMC serial interface Syntax DellStateSettings Access Read write BMC Serial Interface Status Name bmcSerialInterfaceStatus Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 6 Description Defines the status of the BMC serial interface Syntax DellStatus Access Read only 492 Baseboard Management Controller Group BMC Serial Interface Channel Number Name Object ID Description Syntax Access bmcSerialInterfaceChannelNumber 1 3 6 1 4 1 674 10892 1 1900 20 1 7 Defines the BMC channel number of the BMC serial interface DellUnsigned8BitRange Read only BMC Serial Interface Connection Mode Capabilities Name Object ID Description Syntax Access bmc
85. Defines the index one based of this chassis DellObjectRange Read only Keyboard Port Index Name Object ID Description Syntax Access keyboardPort Index 1 3 6 1 4 1 674 10892 1 1000 20 1 2 Defines the index of the keyboard ports in this chassis DellObjectRange Read only Keyboard Port State Capabilities Name Object ID Description Syntax Access keyboardPortStateCapabilities 1 3 6 1 4 1 674 10892 1 1000 20 1 3 Defines the capabilities of the keyboard port DellStateCapabilities Read only Keyboard Port State Settings Name Object ID Description Syntax Access keyboardPortStateSettings 1 3 6 1 4 1 674 10892 1 1000 20 1 4 Defines the state and settings of the keyboard port DellStateSettings Read only PortGroup 213 Keyboard Port Status Name keyboardPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 20 1 5 Description Defines the status of the keyboard port Syntax DellStatus Access Read only Keyboard Port Security State Name keyboardPortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 20 1 6 Description Defines the security settings of the keyboard port Syntax DellPortSecurityState Access Read only Keyboard Port Connector Type Name keyboardPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 20 1 7 Description Defines the connector type of the keyboard port Syntax DellKeyboardPortConnectorType See Table 12 2 Access Read only Keyboard Port Name Name keybo
86. Defines the security settings of the serial port Syntax DellPortSecurityState Access Read only Serial Port Connector Type Name serialPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 7 Description Defines connector type of the serial port Syntax DellSerialPortConnectorType Access Read only Serial Port Name Name serialPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 8 Description Defines the name of the serial port Syntax DellString Access Read only 232 Port Group Serial Port Maximum Speed Name serial PortMaximumSpeed Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 9 Description Defines the maximum speed the serial interface can support in bits per second bps Syntax DellUnsigned32BitRange Access Read only Serial Port Capabilities Unique Name serialPortCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 10 Description Defines additional capabilities of the serial port Syntax DellSerialPortCapabilitiesUnique Access Read only Serial Port Base 1 0 Address Name serialPortBaselOAddress Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 11 Description Defines the base I O address of the serial port Syntax DellUnsigned64BitRange Access Read only Serial Port IRO Level Name serialPortIRQLevel Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 12 Description Defines the IRQ of the serial port Syntax DellUnsigned BitRange Access Read only PortGroup 233 Universal Serial Bus USB Port
87. Defines the starting address of the system BIOS A zero 0 indicates that the address is unknown Syntax DellUnsigned64BitRange Access Read only System BIOS Ending Address Name systemBIOSEndingAddress Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 10 Description Defines the ending address of the system BIOS A zero 0 indicates that the address is unknown Syntax DellUnsigned64BitRange Access Read only 86 Chassis Information Group System BIOS Manufacturer Name Name Object ID Description Syntax Access systemBIOSManufacturerName 1 3 6 1 4 1 674 10892 1 300 50 1 11 Defines the system BIOS manufacturer s name DellString Read only System BIOS Characteristics Name Object ID Description systemBIOSCharacteristics 1 3 6 1 4 1 674 10892 1 300 50 1 12 Defines characteristics of the system BIOS This attribute is a bit field where a bit has the meaning defined below when set to 1 one Bit 63 is the first bit in the value and bit 0 is the last bit in the value See the description of DellUnsigned64BitRange at the beginning of this file for more information on the format of the value Bits 48 63 need to be examined in the context of the system ID The system ID is available in the attribute chassisID If the value for chassisID is non zero bits 48 63 have the meaning defined below Bit Position Meaning if Set Bit OReserved Bit 1Reserved Bit 2Unknown Bit 3BIOS Characteristics Not Supported Bit 4ISA
88. Description Defines the Firmware Table Syntax SEQUENCE OF FirmwareTableEntry Access Not accessible Firmware Table Entry Name firmwareTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 Description Defines the Firmware Table entry Syntax Firmware TableEntry Access Not accessible Index firmwarechassisIndex firmwarelndex Firmware Chassis Index Name firmwarechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Firmware Index Name firmwareIndex Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 2 Description Defines the index one based of the firmware in this chassis Syntax DellObjectRange Access Read only 90 Chassis Information Group Firmware State Capabilities Name Object ID Description Syntax Access firmwareStateCapabilities 1 3 6 1 4 1 674 10892 1 300 60 1 3 Defines the capabilities of the firmware states DellStateCapabilities Read only Firmware State Capabilities Name Object ID Description Syntax Access firmwareStateCapabilities 1 3 6 1 4 1 674 10892 1 300 60 1 4 Defines the state of the firmware and allows for the setting of the firmware DellStateSettings Read write Firmware Status Name Object ID Description Syntax Access firmwareStatus 1 3 6 1 4 1 674 10892 1 300 60 1 5 Defines the status of the firmware DellStateSettings Read only Firmware
89. Device Number Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceDeviceNumber 1 3 6 1 4 1 674 10892 1 1100 82 1 8 Defines the device number of the PCI device in this chassis DellUnsigned32BitRange Read only Device Group 283 PCI Device Configuration Space Function Number Name Object ID Description Syntax Access pCiIDeviceConfigurationSpaceFunct ionNumber 1 3 6 1 4 1 674 10892 1 1100 82 1 9 Defines the function number of the PCI device in this chassis DellUnsigned32BitRange Read only PCI Device Configuration Space Header Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceHeader 1 3 6 1 4 1 674 10892 1 1100 82 1 10 Defines the common configuration space header of the PCI device OCTET STRING SIZE 0 1025 Read only Network Device Table Name Object ID Description Syntax Access networkDeviceTable 1 3 6 1 4 1 674 10892 1 1100 90 Defines the Network Device Table SEQUENCE OF NetworkDeviceTableEntry Not accessible Network Device Table Entry Name Object ID Description Syntax Access Index 284 networkDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 90 1 Defines the Network Device Table Entry NetworkDeviceTableEntry Not accessible networkDeviceChassisIndex networkDeviceIndex Device Group Network Device Chassis Index Name networkDeviceChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 1 Description Defines the index
90. Management Group Virtual Disk Current Stripe Size in Bytes Name Object ID Description Syntax Access virtualDiskCurStripeSizeInBytes 1 3 6 1 4 1 674 10893 1 20 140 1 1 15 Identifies the portion of the stripe size in bytes that is smaller than a megabyte This size plus the virtualDiskCurStripeSizeInMB is the total stripe size on the virtual disk Integer Read only Virtual Disk Channel Name virtualDiskChannel Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 16 Description This entry is obsolete This property is not supported by virtual disks managed under Storage Management Syntax Integer Access Read only Virtual Disk Target ID Name virtualDiskTargetID Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 17 Description Unique ID for the virtual disk Syntax Integer Access Read only Virtual Disk LUN ID Name Object ID Description Syntax Access virtualDiskLunID 1 3 6 1 4 1 674 10893 1 20 140 1 1 18 This entry is obsolete This property is not supported by virtual disks managed under Storage Management Integer Read only Storage Management Group 611 Virtual Disk Roll Up Status Name virtualDiskRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 19 Description Severity of the virtual disk state This is the combined status of the virtual disk and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus
91. Object ID Description Syntax Access genericDeviceType 1 3 6 1 4 1 674 10892 1 1100 70 1 7 Defines the type of the generic device DellGenericDeviceType See Table 13 18 Read only Device Group 277 Generic Device Name Name genericDeviceName Object ID 1 3 6 1 4 1 674 10892 1 1100 70 1 8 Description Defines the name of the generic device Syntax DellString Access Read only PCI Device Table Name pCIDeviceTable Object ID 1 3 6 1 4 1 674 10892 1 1100 80 Description Defines the PCI Device Detail Table Syntax SEQUENCE OF PCIDeviceTableEntry Access Not accessible PCI Device Table Entry Name pCIDeviceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 Description Defines the PCI Device Table entry Syntax Not accessible Access PCIDeviceTableEntry Index pClDevicechassisIndex pCIDeviceIndex PCI Device Chassis Index Name pCIDevicechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 1 Description Defines the index one based of this chassis Syntax Read only Access DellObjectRange 278 Device Group PCI Device Index Name pCIDeviceIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 2 Description Defines the index one based of the PCI device in this chassis Syntax DellObjectRange Access Read only PCI Device State Capabilities Name pCIDeviceStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1100 80 1 3 Description Defines the capabilities of the PCI device Syntax DellStateCapabilities
92. Object ID Description Syntax Access powerUsageChassisIndex 1 3 6 1 4 1 674 10892 1 600 60 1 1 Defines the index one based of the associated chassis DellObjectRange Read only Power Usage Index Name Object ID Description Syntax Access powerUsageIndex 1 3 6 1 4 1 674 10892 1 600 60 1 2 Defines the index one based of the power usage information DellObjectRange Read only Power Usage State Capabilities Name Object ID Description Syntax Access powerUsageStateCapabilities 1 3 6 1 4 1 674 10892 1 600 60 1 3 Defines the state capabilities of the power usage information DellStateCapabilities Read only 166 Power Group Power Usage State Settings Name Object ID Description Syntax Access powerUsageStateSettings 1 3 6 1 4 1 674 10892 1 600 60 1 4 Defines the state settings of the power usage information DellStateSettings Read write Power Usage Status Name Object ID Description Syntax Access powerUsageStatus 1 3 6 1 4 1 674 10892 1 600 60 1 5 Defines the status of the power usage information DellStatus Read only Power Usage Entity Name Name Object ID Description Syntax Access powerUsageEntityName 1 3 6 1 4 1 674 10892 1 600 60 1 6 Defines the name of the entity associated with this power usage information DellString Read only Power Usage Cumulative Wattage Name Object ID Description Syntax Access powerUsageCumulativeWattage 1
93. Object ID 1 3 6 1 4 1 674 10892 1 1800 10 Description Defines the Cluster Table Syntax SEQUENCE OF ClusterTableEntry Access Not accessible Cluster Table Entry Name clusterTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 Description Defines the Cluster Table entry Syntax Cluster TableEntry Access Not accessible Index clusterChassisIndex clusterIndex Cluster Group 483 Cluster Chassis Index Name clusterChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Cluster Index Name clusterIndex Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 2 Description Defines the index one based of the cluster Syntax DellObjectRange Access Read only Cluster State Capabilities Name clusterStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 3 Description Defines the state capabilities of the cluster Syntax DellStateCapabilities Access Read only Cluster State Settings Name clusterStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1800 10 1 4 Description Defines the state settings of the cluster Syntax DellStateSettings Access Read write 484 Cluster Group Cluster Status Name Object ID Description Syntax Access Cluster Type Name Object ID Description Syntax Access clusterStatus 1 3 6 1 4 1 674 10892 1 1800 10 1 5 Defines the status of the cluster DellStatus Read only clusterTyp
94. Operating System Syntax DisplayString Access Read only Change Management Group _ 625 Operating System Service Pack Major Version Name operatingSystemSPMajorVersion Object ID 1 3 6 1 4 1 674 10899 2 5 Description Defines the Operating System s Service Pack major version Syntax DisplayString Access Read only Operating System Service Pack Minor Version Name operatingSystemSPMinorVersion Object ID 1 3 6 1 4 1 674 10899 2 6 Description Defines the Operating System s Service Pack minor version Syntax DisplayString Access Read only Operating System Architecture Name operatingSystemArchitecture Object ID 1 3 6 1 4 1 674 10899 2 7 Description Defines the Operating System s architecture Syntax DisplayString Access Read only Inventory Collector Product Information The following objects describe the fields for the Inventory Collector The Inventory Collector product variables are scalar objects meaning that they are not related to other Inventory Collector base MIB objects and are thus not placed in a table 626 Change Management Group Product ID Display Name Name Object ID Description Syntax Access product IDDisplayName 1 3 6 1 4 1 674 10899 100 1 Defines the display name of the product DisplayString Read only Product ID Description Name productIDDescription Object ID 1 3 6 1 4 1 674 10899 100 2 Description Provides a description of the product Syntax DisplayString Access Read only
95. Please set Please set Please set Oo wo OC O09 0 0 0 ODO W 15 27 1 3 6 2 4 1 3 6 4 HES E 62 eae 1 3 6 1 04 1332 60054 y EEE 86 L 36 1 4 132 6210 44 a3 36s Ae ds 3256 34S AE A P cleared E REE KA E 62 E Ty 1 674 674 674 674 674 674 674 674 674 674 674 674 674 1 3 6 1 4 1 674 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 20050513100047 vals evils sl 300 300 300 300 300 300 300 300 300 300 300 300 300 300 000000 360 10 20 10 10 10 10 40 40 40 40 40 40 40 40 36 1 480 Ee ay ea E E a38 S052 39k Se 72 44 1 30 45 1 0 Lede c T Aiea Sp oll Debet GS 48 raced 2 5 1 1 Log Gebak se 2 Lekel 3 Balete S SNMP Sample Output 687 688 SNMP Sample Output Glossary The following list defines or identifies technical terms abbreviations and g acronyms used in Dell user documents A Abbreviation for ampere s AC Abbreviation for alternating current AC power switch A switch with two AC power inputs that provides AC power redundancy by failing over to a standby AC input in the event of a failure to the primary AC input access Refers to the actions a user can take on a variable value Examples include read only and read write adapter card A
96. Possible Data Values Meaning of Data Value If set to 0 zero unknownCapabilities 1 enableCapable 2 notReadyCapable 4 There are no state capabilities State capabilities are unknown Object enable disable is supported Object not ready is supported Memory Group 345 Table 15 4 Physical Memory Configuration State Settings Variable Name De11PhysicalMemoryConfigStateSettings Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero There are no state settings unknown 1 State settings are unknown enabled 2 Object is disabled offline 0 or enabled online 1 notReady 4 Object not ready redundantMemoryIsActive 8 Redundant memory is active in use enabledAndRedundantMemoryIsActive 10 Redundant memory is enabled and in use Table 15 5 Physical Memory Configuration Redundant Capabilities Variable Name DellPhysicalMemoryConfigRedundantCapabilities Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero There are no redundant memory capabilities unknownCapabilities 1 Redundant capabilities are unknown The redundant capabilities are spareCapable 2 Spare redundant memory feature is supported mirrorCapable 4 Mirror redundant memory feature is supported spareAndMirrorCapable 6 Spare and mirror redundant memory features are supported raidCapable 8 Redundant Array of Independent disks RAID red
97. Read write Device Group Cache Device Status Name cacheDeviceStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 5 Description Defines the status of the cache device Syntax DellStatus Access Read only Cache Device Processor Device Index Reference Name cacheDeviceprocessorDeviceIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 6 Description Defines the index number of the processor device with which this cache device is associated Syntax DellObjectRange Access Read only Cache Device Type Name cacheDeviceType Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 7 Description Defines the type of cache device Syntax DellCacheDeviceType See Table 13 7 Access Read only Cache Device Location Name cacheDeviceLocation Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 8 Description Defines the location of the cache device Syntax DellCacheDeviceLocation See Table 13 13 Access Read only Device Group 261 Cache Device Status State Name Object ID Description Syntax Access cacheDeviceStatusState 1 3 6 1 4 1 674 10892 1 1100 40 1 9 Defines the status state of the cache device DellCacheDeviceStatusState See Table 13 10 Read only Cache Device External Socket Name Name Object ID Description Syntax Access cacheDeviceExternalSocketName 1 3 6 1 4 1 674 10892 1 1100 40 1 10 Defines the external socket name of the cache device if the cache is socketed DellString Read only C
98. Resource Owner Table Name systemResourceOwnerTable Object ID 1 3 6 1 4 1 674 10892 1 500 20 Description Defines the System Resource Owner Table Syntax SEQUENCE OF SystemResourceOwner JableEntry Access Not accessible System Resource Group 121 System Resource Owner Table Entry Name Object ID Description Syntax Access Index systemResourceOwnerTable 1 3 6 1 4 1 674 10892 1 500 20 1 Defines the System Resource Owner Table entry Variables in this group reference the System Resource Map index SystemResourceOwnerTableEntry Not accessible systemResourceOwnerchassisIndex systemResourceOwnerIndex System Resource Owner Chassis Index Name Object ID Description Syntax Access systemResourceOwnerchassisIndex 1 3 6 1 4 1 674 10892 1 500 20 1 1 Defines the index one based of this chassis DellObjectRange Read only System Resource Owner Index Name Object ID Description Syntax Access systemResourceOwnerIndex 1 3 6 1 4 1 674 10892 1 500 20 1 2 Defines the index of system resource owners for this chassis DellObjectRange Read only System Resource Owner State Capabilities Name Object ID Description Syntax Access 122 systemResourceOwnerStateCapabilities 1 3 6 1 4 1 674 10892 1 500 20 1 3 Defines the capabilities of this system resource owner DellStateCapabilities Read only System Resource Group System Resource Owner State Settings Name Object ID Description Synta
99. Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Current sensor value in Amps lt Reading gt If sensor type is discrete Discrete current state lt State gt Amperage Probe Nonrecoverable 1205 Current sensor detected a Error non recoverable value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Current sensor value in Amps lt Reading gt If sensor type is discrete Discrete current state lt State gt A current sensor on the power supply for the specified system exceeded its failure threshold The sensor location chassis location previous state and current sensor value are provided A current sensor in the specified system detected an error from which it cannot recover The sensor location chassis location previous state and current sensor value are provided 646 Traps Chassis Intrusion Traps Chassis intrusion traps are a security measure Chassis intrusion means that someone is opening the cover to a system s chassis Alerts are sent to prevent unauthorized removal of parts from a chassis Table 25 7 Chassis Intrusion Traps Trap ID Description Cause Chassis Intrusion Normal 1252 Chassis intrusion returned Information to normal Sensor locat
100. Settings Name systemResourceMemoryStateSettings Object ID 1 3 6 1 4 1 674 10892 1 500 40 1 4 Description Defines the state of this system resource memory Syntax DellObjectRange Access Read write System Resource Memory Status Name systemResourceMemoryStatus Object ID 1 3 6 1 4 1 674 10892 1 500 40 1 5 Description Defines the status of this system resource memory Syntax DellStatus Access Read only 128 System Resource Group System Resource Memory Owner Index Reference Name Object ID Description Syntax Access systemResourceMemoryOwnerIndexReference 1 3 6 1 4 1 674 10892 1 500 40 1 6 Defines the index to the associated system resource owner in this chassis DellObjectRange Read only System Resource Memory Share Disposition Name Object ID Description Syntax Access systemResourceMemoryShareDisposition 1 3 6 1 4 1 674 10892 1 500 40 1 7 Defines the share disposition of the system resource memory DellResourceShareDisposition See Table 7 3 Read only System Resource Memory Starting Address Name Object ID Description Syntax Access systemResourceMemoryStartingAddress 1 3 6 1 4 1 674 10892 1 500 40 1 8 Defines the 64 bits of the starting address of the system resource memory DellUnsigned64BitRange Read only System Resource Memory Ending Address Name Object ID Description Syntax Access systemResourceMemoryEndingAddress 1 3 6 1 4 1 674 10892 1 500 40 1 9
101. Table Name sCSIPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 60 Description Defines the SCSI Port Table Syntax IntegerSCS PortTableEntry Access Not accessible SCSI Port Table Entry Name sCSIPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 Description Defines the SCSI Port Table entry Syntax SCSIPortTableEntry Access Not accessible Index sCS PortchassisIndex sCSIPortIndex SCSI Port Chassis Index Name sCSIPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only SCSI Port Index Name sCSIPort Index Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 2 Description Defines the index of the SCSI ports in this chassis Syntax DellObjectRange Access Read only 224 Port Group SCSI Port State Capabilities Name Object ID Description Syntax Access sCSIPortStateCapabilities 1 3 6 1 4 1 674 10892 1 1000 60 1 3 Defines the capabilities of the SCSI port DellStateCapabilities Read only SCSI Port State Settings Name DellStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 4 Description Defines the state and settings of the SCSI port Syntax DellStatus Access Read write SCSI Port Status Name sCSIPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 5 Description Defines the status of the SCSI port Syntax DellStatus Access Read only SCSI Port Security State Name sCSIPortSecurityState Ob
102. Table Name uSBPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 90 Description Defines the USB Port Table Syntax IntegerUSBPortTableEntry Access Not accessible USB Port Table Entry Name uSBPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 Description Defines the USB Port Table entry Syntax USBPortTableEntry Access Not accessible Index uSBPortchassisIndex uSBPortIndex USB Port Chassis Index Name uSBPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only USB Port Index Name uSBPort Index Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 2 Description Defines the index of the USB ports in this chassis Syntax DellObjectRange Access Read only 234 Port Group USB Port State Capabilities Name Object ID Description uSBPortStateCapabilities 1 3 6 1 4 1 674 10892 1 1000 90 1 3 Defines the capabilities of the USB port Syntax DellStateCapabilities Access Read only USB Port State Settings Name uSBPortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 4 Description Defines the state and settings of the USB port Syntax DellStateSettings Access Read write USB Port Status Name uSBPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 90 1 5 Description Defines the state of the USB port Syntax DellStatus Access Read only USB Port Security State Name uSBPortSecurityState Object ID 1 3 6
103. The power button settings are unknown enabled 2 The power button state is enabled disabled 4 The power button state is disabled 108 l Chassis Information Group Table 5 18 NMI Button Control Capabilities Variable Name De 1 LINMIButtonControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The NMI button has no capabilities unknownCapabilities 1 The NMI button capabilities are unknown enableCapable 2 The NMI button can be enabled online or disabled offline Table 5 19 NMI Button Control Settings Variable Name De1 INMIButtonControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The NMI button has no settings capabilities unknown 1 The NMI button settings are unknown enabled 2 The NMI button state is enabled disabled 4 The NMI button state is disabled Table 5 20 Chassis System Class Variable Name De11ChassisSystemClass Data Type Integer Possible Data Values Meaning of Data Value other 1 The chassis system class is not one of the following unknown 2 The chassis system class is unknown workstationClass 3 The chassis system class is a workstation serverClass 4 The chassis system class is a server desktopClass 5 The chassis system class is a desktop portableClass 6 The chassis system class is a portable net PCClass 7 The chassis system class is a Net PC storageC
104. The processor family is UltraSPARC Ili deviceFamilyIsUltraSPARCIII 87 The processor family is UltraSPARC IIL deviceFamilyIsUltraSPARCIIIi The processor family is UltraSPARC IIi 88 deviceFamily1Is68040 96 The processor family is 68040 Family deviceFamilyIs68xxx 97 The processor family is 68xxx deviceFamilyIs68000 98 The processor family is 68000 deviceFamilyIs68010 99 The processor family is 68010 deviceFamilyIs68020 100 The processor family is 68020 deviceFamilyIs68030 101 The processor family is 68030 deviceFamilyIsHobbit 112 The processor family is Hobbit deviceFamilyIsCrusoeTM5000 120 The processor family is Crusoe TM5000 deviceFamilyIsCrusoeTM3000 121 The processor family is Crusoe TM3000 deviceFamilyIsEfficeonTM8000 The processor family is Efficeon 122 TM8000 deviceFamilyIsWeitek 128 The processor family is Weitek deviceFamilyIsAMDAthlon 4 131 The processor family is AMD Athlon 64 deviceFamilyIsAMDOpteron 132 The processor family is AMD Opteron deviceFamilyIsAMDSempron 133 The processor family is AMD Sempron deviceFamilyIsAMDTurion64Mobile The processor family is AMD Turion 134 64 Mobile Technology 298 Device Group Table 13 6 Processor Device Family continued Variable Name De1 1 ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsDualCoreamDOpter The processor family is Dual Core AMD
105. This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Storage Management Group 527 Controller C1 Port 1 World Wide Name Name controllerCl1Port1WWN Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 35 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller Battery Charge Count Name controllerBatteryChargeCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 36 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller Roll Up Status Name controllerRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 37 Description Indicates severity of the controller state This is the combined status of the controller and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 528 Storage Management Group Controller Component Status Name Object ID Description Syntax Access controllerComponentStatus 1 3 6 1 4 1 674 10893 1 20 130 1 1 38 Indicates the status of the controller itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Controller Nexus ID Name Ob
106. Unit Table entry Syntax DellObjectRange Access Read only Index powerUnitchassisIndex powerUnitIndex Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Power Unit Index Name powerUnit Index Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 2 Description Defines the index of the power unit in this chassis Syntax DellObjectRange Access Read only Power Unit State Capabilities Name powerUnitStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 3 Description Defines the capabilities of the power unit Syntax DellStateCapabilities Access Read only 142 Power Group Power Unit State Settings Name Object ID Description Syntax Access powerUnitStateSettings 1 3 6 1 4 1 674 10892 1 600 10 1 4 Defines the state and settings of the power unit DellStateSettings Read write Power Unit Redundancy Status Name Object ID Description Syntax Access powerUnitRedundancyStatus 1 3 6 1 4 1 674 10892 1 600 10 1 5 Defines the redundancy status of the power unit DellStatusRedundancy Read only Power Supply Count for Redundancy Name Object ID Description Syntax Access Power Unit Name Name Object ID Description Syntax Access powerSupplyCount ForRedundancy 1 3 6 1 4 1 674 10892 1 600 10 1 6 Defines the total number of power supplies require
107. Values Meaning of Data Value deviceLocationIsOther 1 Device location is not one of the following deviceLocationIsUnknown 2 Device location is unknown deviceLocationIsInternal 3 Device location is internal deviceLocationIsExternal 4 Device location is external Device Group 303 Table 13 14 Cache Device Static Random Access Memory SRAM Type Variable Name De11CacheDeviceSRAMType Data Type Integer Possible Data Values Meaning of Data Value deviceSRAMTypelIsOther 1 Device SRAM type is not one of the following deviceSRAMTypelIsUnknown 2 Device SRAM type is unknown deviceSRAMTypeIsNonBurst 3 Device SRAM type is nonburst deviceSRAMTypelIsBurst 4 Device SRAM type is burst deviceSRAMTypelIsPipeBurst 5 Device SRAM type is pipeburst deviceSRAMTypeIsSynchronous 6 Device SRAM type is synchronous deviceSRAMTypelIsAsynchronous 7 Device SRAM type is asynchronous Table 13 15 Memory Device Type Form Factor Variable Name De 1 1MemoryDeviceFormFactor Data Type Integer Possible Data Values Meaning of Data Value deviceFormFactorIsOther 1 Device form factor is not one of the following deviceFormFactorIsUnknown 2 Device form factor is unknown deviceFormFactorIsSIMM 3 deviceFormFactorIsSIP 4 deviceFormFactorIsAChip 5 deviceFormFactorIsDIP 6 deviceFormFactorIsZIP 7 Device form factor is SIMM Device form factor is SIP Device form
108. Variable Name De1 1ResourceMemoryFlags Data Type Integer Possible Data Values Meaning of Data Value memoryIsReadOnly 1 The resource memory is read only memoryIsWriteOnly 2 The resource memory is write only memoryIsPreFetchable 4 The resource memory is prefetchable memoryIsCombinedWritable 8 The resource memory is read write memoryIsF24 16 The resource memory is F24 System Resource Group 137 138 Table 7 5 Resource Interrupt Type Variable Name De1 1ResourceInterruptType Data Type Integer Possible Data Values Meaning of Data Value interruptIsLevelSensitive 1 The interrupt type is level sensitive interruptIsLatched 2 The interrupt type is latched Table 7 6 Resource Interrupt Trigger Variable Name De1 LResourceInterruptTrigger Data Type Integer Possible Data Values Meaning of Data Value interruptIsActiveWhenLow 1 The interrupt trigger is active on a low signal interruptIsActiveWhenHigh 2 The interrupt trigger is active on a high signal Table 7 7 Resource DMA Bus Master Variable Name De 1 1 ResourceDMABusMaster Data Type Integer Possible Data Values Meaning of Data Value dmalIsOther 1 The DMA bus master capability is not one of the following dmaIsUnknown 2 The DMA bus master capability is unknown dmaIsNotABusmaster 3 The DMA does not have bus master capability l System Resource Group Table 7 8
109. Variable Name De11ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsIntelPentiumM 185 deviceFamilyIsIntelCeleronD 186 deviceFamilyIsIntelPentiumD 187 The processor family is Intel Pentium M The processor family is Intel Celeron D The processor family is Intel Pentium D deviceFamilyIsIntelPentiumExtr The processor family is Intel Pentium eme 188 deviceFamilyIsIntelCore2 190 deviceFamilyIsIBM390 200 deviceFamilyIsG4 201 deviceFamilyIsG5 202 deviceFamilyIsi860 250 deviceFamilyIsi960 251 Processor Extreme Edition The processor family is Intel Core 2 processor The processor family is IBM390 The processor family is G4 The processor family is G5 The processor family is i860 The processor family is i960 Table 13 7 Cache Device Type Variable Name De11CacheDeviceType Data Type Integer Possible Data Values deviceTypelIsOther 1 deviceTypelIsUnknown 2 deviceTypelIsInstruction 3 deviceTypelIsData 4 deviceTypelsUnified 5 Meaning of Data Value System cache type is not one of the following System cache type is unknown System cache type is instruction System cache type is data System cache type is both instruction and data 300 Device Group Table 13 8 Cache Device Level Variable Name De 1 1 CacheDeviceLevel Data Type Integer Possible Data Values
110. Warranty State Name cooWarrantyState Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 3 Description Defines the state of the warranty for this system Syntax DellStateSettings Access Read only COO Warranty Duration Name cooWarrantyDuration Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 4 Description Defines the duration of the warranty Syntax DellUnsigned32BitRange Access Read write COO Warranty Duration Type Name cooWarrantyDurationType Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 5 Description Defines the warranty duration type for the system Syntax DellCOODayMonthDuration Type Access Read write COO Warranty End Date Name Name cooWarrant yEndDateName Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 6 Description Defines the warranty end date for this system Syntax DellDateName Access Read write Cost of Ownership Group 409 COO Warranty Cost Name cooWarrantyCost Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 7 Description Defines the cost of the warranty for this system Syntax DellUnsigned32BitRange Access Read write COO Lease Information Table The COO lease information MIB objects enable you to track information about your lessor lease duration and lease type for each system Name cooLeaseInformationTable Object ID 1 3 6 1 4 1 674 10892 1 1600 50 Description Defines the COO Lease Information Table Syntax SEQUENCE OF CooLeaselnformationTableEntry Access Not accessible COO Lease Information Table Entry
111. accessible Index channelNumber Channel Number Name channelNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 1 Description Identifies the instance number of the channel entry Syntax Integer Access Read only 534 Storage Management Group Channel Name Name Object ID Description Syntax Access Channel State Name Object ID Description Syntax Access channelName 1 3 6 1 4 1 674 10893 1 20 130 2 1 2 Identifies the name of the channel as represented in Storage Management The name will include the word channel and the instance For example Channel 1 DisplayString Read only channelState 1 3 6 1 4 1 674 10893 1 20 130 2 1 3 Identifies the current state of this channel Possible states 0 Unknown 1 Ready The I O has resumed 2 Failed 3 Online 4 Offline The I O has paused 6 Degraded Integer Read only Channel Severity Name Object ID Description Syntax Access channelSeverity 1 3 6 1 4 1 674 10893 1 20 130 2 1 4 This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Integer Read only Storage Management Group 535 Channel Termination Name Object ID Description Syntax Access channelTermination 1 3 6 1 4 1 674 10893 1 20 130 2 1 5 Identifies the type of SCSI termination on this channel Termination is required for proper operation of this channel Possible values
112. based of the BMC Syntax DellObjectRange Access Read only BMC State Capabilities Name bmcStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 3 Description Defines the state capabilities of the BMC Syntax DellStateCapabilities Access Read only 488 Baseboard Management Controller Group BMC State Settings Name bmcStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 4 Description Defines the state settings of the BMC Syntax DellStateSettings Access Read write BMC Status Name bmcStatus Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 5 Description Defines the status of the BMC Syntax DellStatus Access Read only BMC Display Name Name bmcDisplayName Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 6 Description Defines the display name of the BMC Syntax DellString Access Read only BMC Description Name Name bmcDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 7 Description Defines the description of the BMC Syntax DisplayString SIZE 0 255 Access Read only Baseboard Management Controller Group 489 BMC IPMI Version Name Name bmcIPMIVersionName Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 8 Description Defines the version of the Intelligent Platform Management Interface IPMI specification that the BMC supports Syntax DellString Access Read only BMC GUID Name bmcGUID Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 9 Description Defines the Globally Unique ID GUID of the BM
113. belongs Syntax Integer Access Read only 580 Storage Management Group Temperature Probe Table This table describes available properties for each temperature probe on the managed system The following object sets up the Temperature Probe Table Name Object ID Description Syntax Access temperatureProbeTable 1 3 6 1 4 1 674 10893 1 20 130 11 A table of managed temperature probes The number of entries is related to the number of temperature probes discovered in the system The maximum number of entries is implementation dependent NOTE The properties in this table may not be applicable to all entries SEQUENCE OF TemperatureProbeEntry Not accessible Temperature Probe Entry Name Object ID Description Syntax Access Index temperatureProbeEntry 1 3 6 1 4 1 674 10893 1 20 130 11 1 An entry in the Temperature Probe Table A row in this table cannot be created or deleted by SNMP operations on columns of the table TemperatureProbeEntry Not accessible Temperature ProbeNumber Temperature Probe Number Name Object ID Description Syntax Access temperatureProbeNumber 1 3 6 1 4 1 674 10893 1 20 130 11 1 1 Identifies the instance number of the temperature probe entry Integer Read only Storage Management Group 581 Temperature Probe Name Name temperatureProbeName Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 2 Description Identifies the temperature probe s name as
114. bus width is 1x or x1 busWidthIs2xOrx2 9 The system slot bus width is 2x or x2 busWidthIs4xOrx4 10 The system slot bus width is 4x or x4 busWidthIs8xOrx8 11 The system slot bus width is 8x or x8 busWidthIs12x0rx12 12 The system slot bus width is 12x or x12 busWidthIs16xOrx16 13 The system slot bus width is 16x or x16 busWidthIs32x0rx32 14 The system slot bus width is 32x or x32 K NOTE System slot bus width of type n bits are for parallel buses such as PCI K NOTE System slot bus width of type nx or xn are for serial buses such as PCI Express 324 Slot Group Memory Group The Memory Group provides information about the physical memory in your system Variables in this group include error correction type location and different types of memory use such as cache flash system video and nonvolatile memory Physical Memory Tables The following management information base MIB tables define the objects in the Memory Group e Physical Memory Array Table e Physical Memory Array Mapped Table e Physical Memory Configuration Table e Physical Memory Logging Table e Redundant Memory Unit Table e Physical Memory Card Table Physical Memory Array Table The physical memory array is the entire physical memory of a system The example that follows shows variable values for a system that has one 128 megabyte MB dual in line memory module DIMM e physicalMemoryArrayMaximumSize 2 097 1
115. chassis gt Chassis location lt Name of chassis gt Previous redundancy state was lt State gt Number of devices required for full redundancy lt Number gt Warning or Error depending on the number of units that are functional specified system detected that one of the components of the redundancy unit has failed but the unit is still redundant The redundancy unit location chassis location and previous redundancy state are provided A redundancy sensor in the specified system detected that one of the components in the redundant unit has been disconnected has failed or is not present The redundancy unit location chassis location and previous redundancy state are provided Traps 649 Power Supply Traps Power supply traps provide status and warning information for power supplies present in a particular chassis Table 25 9 Power Supply Traps Trap ID Description Severity Cause Power Supply Normal 1352 Power supply returned Information A power supply has been to normal reconnected or replaced The sensor location chassis location previous state and additional information Sensor location lt Location in chassis gt Chassis location about the power supply lt Name of chassis gt event are provided Previous state was lt State gt Power Supply type lt type of power supply gt lt Additional power supply status information gt If in configuration
116. colors group As it relates to DMI a group is a data structure that defines common information or attributes about a manageable component GTL Abbreviation for ground termination logic GUI Acronym for graphical user interface h Abbreviation for hexadecimal A base 16 numbering system often used in programming to identify addresses in the computer s RAM and I O memory addresses for devices The sequence of decimal numbers from 0 through 16 for example is expressed in hexadecimal notation as 0 1 2 3 4 5 6 7 8 9 A B C D E F 10 In text hexadecimal numbers are often followed by h heat sink A metal plate with metal pegs or ribs that help dissipate heat Most microprocessors include a heat sink HIP Abbreviation for Hardware Instrumentation Package HIP HMA Abbreviation for high memory area The first 64 KB of extended memory above 1 MB A memory manager that conforms to the XMS can make the HMA a direct extension of conventional memory See also upper memory area and XMM host adapter A host adapter implements communication between the computer s bus and the controller for a peripheral device hard drive controller subsystems include integrated host adapter circuitry To add a SCSI expansion bus to your system you must install or connect the appropriate host adapter Glossary 701 hot plug The ability to remove and replace a redundant part while the system is being used Also called a hot
117. components 644 Traps Table 25 6 Amperage Probe Traps Trap ID Description Severity Cause Amperage Probe Normal 1202 a normal value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Current sensor value in Amps lt Reading gt If sensor type is discrete Discrete current state lt State gt Amperage Probe Warning 1203 warning value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Current sensor value in Amps lt Reading gt If sensor type is discrete Discrete current state lt State gt Current sensor returned to Information Current sensor detected a Warning A current sensor on the power supply for the specified system returned to a valid range after crossing a failure threshold The sensor location chassis location previous state and current sensor value are provided A current sensor on the power supply for the specified system exceeded its warning threshold The sensor location chassis location previous state and current sensor value are provided Traps 645 Table 25 6 Amperage Probe Traps continued Trap ID Description Severity Cause Amperage Probe Failure 1204 Current sensor detected a Error failure value
118. connection entry Syntax Integer Access Read only Array Disk Enclosure Connection Array Disk Name Name arrayDiskEnclosureConnectionArrayDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 2 Description Identifies the name of the array disk in this connection as represented in Storage Management Syntax DisplayString Access Read only Array Disk Enclosure Connection Array Disk Number Name arrayDiskEnclosureConnectionArrayDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 3 Description Identifies the instance number of the array disk in the arrayDiskTable in this connection Syntax Integer Access Read only Array Disk Enclosure Connection Enclosure Name Name arrayDiskEnclosureConnectionEnclosureName Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 4 Description Identifies the name of the enclosure as represented in Storage Management to which this array disk belongs Syntax DisplayString Access Read only 562 Storage Management Group Array Disk Enclosure Connection Enclosure Number Name arrayDiskEnclosureConnectionEnclosureNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 5 Description Identifies the instance number in the enclosureTable of the enclosure to which this array disk belongs Syntax Integer Access Read only Array Disk Enclosure Connection Controller Name Name arrayDiskEnclosureConnectionControllerName Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 6 Description Identifies the
119. crossing a warning threshold e Critical Error A significant event that indicates actual or imminent loss of data or loss of function such as crossing a failure threshold or a hardware failure Instrumentation Traps This section describes the traps that are generated by the Instrumentation service of the Server Administrator All of the traps documented in this section belong to the MIB enterprise identified by OID 1 3 6 1 4 1 674 10892 1 and are sent with all of the trap variables documented in the section Trap Variables The trap variables are sent in the order in which they are listed The messages in the Description fields below show the format of the message that is sent in the alertMessage varbind If a message in a Description field has multiple lines the message contains newline 0Ah characters that are part of the value in the alertMessage varbind Miscellaneous Traps Table 25 2 lists Miscellaneous traps that inform you that certain alert systems are up and working 636 Traps Table 25 2 Miscellaneous Traps Trap Description Severity Cause ID System Up 1001 Server Administrator startup complete Thermal Shutdown 1004 Thermal shutdown Error protection has been initiated Automatic System Recovery 1006 Automatic System Error Recovery ASR action was performed Action performed was lt Action gt Date and time of action lt Date and time gt Host System Reset 1007 User initiated
120. error state Configuration error type lt type of configuration error gt 650 Traps Table 25 9 Power Supply Traps continued Trap ID Description Severity Cause Power Supply Warning 1353 Power supply detected a Warning warning Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt Power Supply type lt type of power supply gt lt Additional power supply status information gt If in configuration error state Configuration error type lt type of configuration error gt A power supply sensor has detected a warning condition The sensor location chassis location previous state and additional power supply status information are provided Traps 651 Table 25 9 Power Supply Traps continued Trap ID Description Severity Cause Power Supply Failure 1354 Power supply detected a Error failure Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt Power Supply type lt type of power supply gt lt Additional power supply status information gt If in configuration error state Configuration error type lt type of configuration error gt Memory Device Traps A power supply has been disconnected or has failed The sensor location chassis location previous state and additional information about the power sup
121. has exceeded the Correctable Memory Event failure rate eccMultiBitFault 4 Memory device has encountered an Uncorrectable Memory Event eccSingleBitCorrectionLoggingDisabled 8 Correctable Memory Event logging for memory device has been disabled deviceDisabledBySpareActivation 16 Memory device is disabled because of spare memory activation 308 Device Group Table 13 20 Network Device Connection Status Variable Name De 1 1NetworkDeviceConnectionStatus Data Type Integer Possible Data Values Meaning of Data Value unknown 0 Unable to determine connection status connected 1 Media reports that device is connected disconnected 2 Media reports that device is disconnected driverBad 3 Driver cannot be opened to determine status driverDisabled 4 Driver is disabled hardwareInitalizing 10 Hardware is initializing hardwareResetting 11 Hardware is resetting hardwareClosing 12 Hardware is closing down hardwareNotReady 13 Hardware is not ready Table 13 21 Network Device Teaming Flags Variable Name De1 1NetworkDeviceTeamingFlags Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value undefined 0 Teaming flags are undefined noTeam 1 Device is not part of any team teamingEnabled 2 Teaming is enabled adapterFaultToleranceMode 4 Adapter fault tolerance teaming mode loadBalancingMode
122. integrated NIC provided by the remote access hardware Syntax IpAddress Access Read only Remote Access NIC Current Gateway Address Name remoteAccessNICCurrentGatewayAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 32 Description Defines the IP address for the gateway currently being used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read only 442 Remote Access Group Remote Access NIC Current Information From Dynamic Host Configuration Protocol DHCP Name Object ID Description Syntax Access remoteAccessNICCurrent InfoFromDHCP 1 3 6 1 4 1 674 10892 1 1700 10 1 33 Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware DellBoolean Read only Remote User Administration Table Name Object ID Description Syntax Access remoteUserAdminTable 1 3 6 1 4 1 674 10892 1 1700 20 Defines the Remote Access User Administration Table SEQUENCE OF RemoteUserAdminTableEntry Not accessible Remote User Admin Table Entry Name Object ID Description Syntax Access Index remoteUserAdminTableEntry 1 3 6 1 4 1 674 10892 1 1700 20 1 Defines the Remote Access User Administration Table entry RemoteUserAdminTableEntry Not accessible remoteUserAdminChassisIndex remoteUserAdminAdapterIndex remote UserAdminUserIndex Remote Access Group 443 Remote User Admin Chassis Index
123. is supported Bit 5MCA is supported Bit 6EISA is supported Bit 7PCI is supported Bit 8PC Card PCMCIA is supported Bit 9Plug and Play is supported Bit 10APM is supported Bit 11BIOS is Upgradeable Flash Bit 12BIOS shadowing is allowed Bit 13VL VESA is supported Bit 14ESCD support is available Bit 15Boot from CD is supported Chassis Information Group 87 Name systemBlIOSCharacteristics Description Bit Position Meaning if Set Bit 16Selectable Boot is supported Bit 17BIOS ROM is socketed Bit 18Boot From PC Card PCMCIA is supported Bit 19EDD Enhanced Disk Drive Specification is supported Bit 20Int 13h Japanese Floppy for NEC 9800 1 2mb 3 5 in 1k Bytes Sector 360 RPM is supported Bit 21 Int 13h Japanese Floppy for Toshiba 1 2mb 3 5 in 360 RPM is supported Bit 22Int 13h 5 25 in 360 KB Floppy Services are supported Bit 23Int 13h 5 25 in 1 2MB Floppy Services are supported Bit 24Int 13h 3 5 in 720 KB Floppy Services are supported Bit 25Int 13h 3 5 in 2 88 MB Floppy Services are supported Bit 26Int 5h Print Screen Service is supported Bit 27Int 9h 8042 Keyboard services are supported Bit 28Int 14h Serial Services are supported Bit 29Int 17h Printer Services are supported Bit 30Int 10h CGA Mono Video Services are supported Bit 3INEC PC 98 Bit 32 47Reserved Bit 48Built in NIC supports Magic Packet Bit 49System supports Wake on LAN Bit 50System supports chassis intrusion Bit 51 Bui
124. is usually stored on ROM chips Shadowing refers to the performance enhancement technique that copies BIOS code to faster RAM chips in the upper memory area above 640 KB during the boot routine Glossary 715 SIMD Abbreviation for Single Instruction Multiple Data SIMM Acronym for single in line memory module A small circuit board containing DRAM chips that connects to the system board SIP Acronym for single in line package which is a type of housing for electronic components in which the connecting pins protrude from one side A SIP is also called a Single In line Pin Package SIPP SKU Acronym for stock keeping unit SMART Acronym for Self Monitoring Analysis Reporting Technology A technology that allows hard drives to report errors and failures to the system BIOS which then displays an error message on the screen To take advantage of this technology you must have a SMART compliant hard drive and the proper support in the system BIOS SMBIOS Acronym for system management BIOS SMD Acronym for surface mount device SNMP Abbreviation for Simple Network Management Protocol SNMP is an industry standard interface that allows a network manager to remotely monitor and manage workstations SODIMM Acronym for small outline DIMM A DIMM module with a thinner profile due to the use of TSOP chip packages SODIMMs are commonly used in laptop computers SOIC Acronym for Small Outline IC a small dimension pl
125. log Viewing Alerts Storage Management generates alerts that are added to the Windows application alert log and to the Server Administrator Alert log To view these alerts in Server Administrator 1 Select the System object in the tree view 2 Select the Logs tab 3 Select the Alert subtab Storage Management Alert Reference 673 K NOTE You can also view these alerts in the Windows Event Viewer Every alert consists of the following e Severity Shows the severity of alert e Date and Time Date and time when Storage Management logged the alert Description A brief description of the alert To expand or collapse the alert description click the Description column heading Alert Severity Levels Each alert message in the Storage Management alert log has a severity level The severity level is displayed in the Severity field of the alert message The severity level indicates the nature of the alert The alert severity levels are as follows Table 26 1 Storage Management Alert Severity Alert Severity Component Status OK Normal Informational No action is required The alert is provided for informational purposes and does not indicate an error condition For example the alert may indicate the normal start or stop of an operation Warning Non critical A component requires attention This alert indicates a potential problem but does not necessarily mean that the system has currently lost data or is non
126. mapped address Syntax DellStateCapabilities Access Read only Memory Device Mapped Address State Settings Name memoryDeviceMappedAddressStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1100 60 1 4 Description Defines the state of the memory device mapped address Syntax DellStateSettings Access Read write Device Group 273 Memory Device Mapped Address Status Name Object ID Description Syntax Access memoryDeviceMappedAddressStatus 1 3 6 1 4 1 674 10892 1 1100 60 1 5 Defines the status of the memory device mapped address DellStatus Read only Memory Device Index Reference Name Object ID Description Syntax Access memoryDeviceIndexReference 1 3 6 1 4 1 674 10892 1 1100 60 1 6 Defines the index of the memory device s associated with this memory device mapped address DellObjectRange Read only Memory Device Mapped Address Row Position Name Object ID Description Syntax Access memoryDeviceMappedAddressRowPosition 1 3 6 1 4 1 674 10892 1 1100 60 1 7 Defines the position of the referenced memory in a row of the memory device mapped address DellUnsigned32BitRange Read only Memory Device Mapped Address Interleave Position Name Object ID Description Syntax Access 274 memoryDeviceMappedAddressInterleavePosition 1 3 6 1 4 1 674 10892 1 1100 60 1 8 Defines the position of the referenced memory in an interleave of the memory device mapped address DellU
127. memory Most VGA and SVGA video adapters include memory chips in addition to your computer s RAM The amount of video memory installed primarily influences the number of colors that a program can display with the appropriate video drivers and monitor capabilities video mode Video adapters normally support multiple text and graphics display modes Character based software displays in text modes that can be defined as x columns by y rows of characters Graphics based software displays in graphics modes that can be defined as x horizontal by y vertical pixels by z colors video resolution Video resolution 800 x 600 for example is expressed as the number of pixels across by the number of pixels up and down To display a program at a specific graphics resolution you must install the appropriate video drivers and your monitor must support the resolution Glossary 723 virtual memory A method for increasing addressable RAM by using the hard drive For example in a computer with 16 MB of RAM and 16 MB of virtual memory set up on the hard drive the operating system would manage the system as though it had 32 MB of physical RAM virus A self starting program designed to inconvenience you Virus programs have been known to corrupt the files stored on a hard drive or to replicate themselves until a computer or network runs out of memory The most common way that virus programs move from one computer to another is via infected di
128. of disk operations Transform Type Reconfiguration and Check Consistency 24 Rebuild 25 No Media CD ROM or removable disk has no media 26 Formatting In the process of formatting 28 Diagnostics Diagnostics are running 34 Predictive Failure 35 Initializing Applies only to virtual disks on PERC PERC 2 SC and PERC 2 DC controllers 39 Foreign 40 Clear 41 Unsupported 53 Incompatible Integer Read only Storage Management Group 551 Array Disk Severity Name arrayDiskSeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 5 Description This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Syntax Integer Access Read only Array Disk Product ID Name arrayDiskProductID Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 6 Description Identifies the model number of the array disk Syntax DisplayString Access Read only Array Disk Serial Number Name arrayDiskSerialNo Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 7 Description Identifies the array disk s unique identification number from the manufacturer Syntax DisplayString Access Read only Array Disk Revision Name arrayDiskRevision Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 8 Description Identifies the firmware version of the array disk Syntax DisplayString Access Read only 552 Storage Management Group Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1 3
129. of the last BIOS update Syntax DellDateName Access Read only Remote Flash BIOS Completion Code Name remoteFlashBIOSCompletionCode Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 7 Description Defines the completion code of the last BIOS update Syntax DellRemoteFlashBIOSCompletionCode See Table 11 3 Access Read only Remote Flash BIOS Minimum Contiguous Memory Name remoteFlashBIOSMinimumContiguousMemory Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 8 Description Defines the minimum size of contiguous memory required for remote BIOS update in kilobytes Syntax DellUnsigned32BitRange Access Read only Remote Flash BIOS Group 205 Remote Flash BIOS Variable Values This section includes definitions for server administrator specific variable values used in this section Table 11 1 Remote Flash BIOS State Capabilities Unique Variable Name De1 1RemoteFlashBIOSStateCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The remote flash BIOS s capabilities are unknown enableCapable 2 The remote flash BIOS can be disabled offline a binary 0 value or enabled online a binary 1 value notReadyCapable 4 The remote flash BIOS can be set to indicate not ready cancelCapable 8 Flash of BIOS can be canceled enableAndCancelCapable 10 Flash of BIOS can be enabled or canceled Table 11 2 Remote Flash BIOS State Settings Variable Name De1 1RemoteFlashBIOSState
130. one based of the chassis that contains the network device Syntax DellObjectRange Access Read only Network Device Index Name networkDeviceIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 2 Description Defines the index one based of the network device Syntax DellObjectRange Access Read only Network Device Status Name networkDeviceStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 3 Description Defines the status of the network device Syntax DellStatus Access Read only Network Device Connection Status Name networkDeviceConnectionStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 4 Description Defines the connection status of the network device Syntax DellNetworkDeviceConnectionStatus see Table 13 20 Access Read only Device Group 285 Network Device Description Name Name Object ID Description Syntax Access networkDeviceDescriptionName 1 3 6 1 4 1 674 10892 1 1100 90 1 5 Defines the description of the network device DellString Read only Network Device Product Name Name Object ID Description Syntax Access networkDeviceProductName 1 3 6 1 4 1 674 10892 1 1100 90 1 6 Defines the product name of the network device DellString Read only Network Device Vendor Name Name Object ID Description Syntax Access networkDeviceVendorName 1 3 6 1 4 1 674 10892 1 1100 90 1 7 Defines the name of the vendor of the network device DellString Read only Network Device Service N
131. only Array Disk Logical Connection Virtual Disk Number Name arrayDiskLogicalConnectionVirtualDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 5 Description Identifies the instance number of the virtual disk to which this array disk belongs Syntax Integer Access Read only Array Disk Logical Connection Disk Name Name arrayDiskLogicalConnectionDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 6 Description Identifies the name of the disk group to which this array disk belongs This property is currently not supported Syntax DisplayString Access Read only Storage Management Group 615 Array Disk Logical Connection Disk Number Name arrayDiskLogicalConnectionDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 7 Description Identifies the instance number of the disk group to which this array disk belongs This property is currently not supported Syntax Integer Access Read only Storage Management Event Group The Storage Management Event Group defines the properties that will be sent with SNMP traps Message ID Event Name messageIDEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 1 Description Storage Management event message number Syntax Integer Access Read only Description Event Name descriptionEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 2 Description Storage Management event message text describing the alert Syntax DisplayString Access Read only 616 Storage Management
132. or On Off for example Fan sensor value in RPM 2600 Fan sensor value Off Specifies the type of hardware log for example Embedded Server ESM Log type Management Specifies the name of the memory bank in the system that generated the message for example Memory device bank location Bank_1 Specifies the location of the memory module in the chassis for example Memory device location DIMM A Specifies the number of power supply or cooling devices required to achieve full redundancy for example Number of devices required for full redundancy 4 Specifies a list of possible causes for the memory module event for example Possible memory module event cause Single bit warning error rate exceeded Single bit error logging disabled Table 25 1 Trap Description Reference continued Description Line Item Explanation Power Supply type lt type of power supply gt Pre failure state was lt State gt Previous redundancy state was lt State gt Previous state was lt State gt Processor sensor status lt status gt Redundancy unit lt Redundancy location in chassis gt Sensor location lt Location in chassis gt Temperature sensor value in degrees Celsius lt Reading gt Voltage sensor value in Volts lt Reading gt Specifies the type of power supply for example Power Supply type VRM Specifies the status of the previous memory message
133. per minute POFP Abbreviation for plastic quad flat pack a type of microprocessor socket in which the microprocessor chip is permanently mounted Glossary m1 protected mode An operating mode supported by 80286 or higher microprocessors protected mode allows operating systems to implement e A memory address space of 16 MB 80286 microprocessor to 4 GB Intel386 or higher microprocessor e Multitasking e Virtual memory a method for increasing addressable memory by using the hard drive Windows OS 2 and UNIX 32 bit operating systems run in protected mode provider A provider is an extension of a CIM schema that communicates with managed objects and accesses data and event notifications from a variety of sources Providers forward this information to the CIM Object Manager for integration and interpretation PS 2 Abbreviation for Personal System 2 PXE Abbreviation for Pre boot eXecution Environment OFP Acronym for quad flat pack RAID Acronym for redundant array of independent drives RAM Acronym for random access memory The computer s primary temporary storage area for program instructions and data Each location in RAM is identified by a number called a memory address Any information stored in RAM is lost when you turn off your computer RAMBUS Acronym for Rambus DRAM a type of memory DRAM developed by Rambus Inc RAMDAC Acronym for random access memory digital to analog converter
134. pointing port connector type is nfrared y connectorPortTypeIsHPHIL 6 he pointing port connector type is T HP HIL y connectorPortTypeIsBusMouse 7 he pointing port connector type is a T bus mouse connectorPortTypeIsADB 8 The pointing port connector type is ADB connectorPortTypeIsDB9 9 The pointing port connector type is 4 nine pin DB 9 connectorPortTypeIsMicroDIN 10 The pointing port connector type is micro Deutsche Industrie Norm DIN connectorPortTypelIsAccessBusUSB The pointing port connector type is 11 Access Bus USB connectorPortTypeIsPC98 12 The port connector type is a PC 98 PortGroup 237 Table 12 2 Keyboard Port Connector Types Variable Name De1 1 KeyboardPortConnectorType Data Type Integer Possible Data Values eaning of Data Value connectorPortTypelsOther 1 The keyboard port connector type is not one of the following connectorPortTypelsUnknown 2 The keyboard port connector type is unknown connectorPortTypeIsMiniDIN 3 The keyboard port connector type is a mini DIN connectorPortTypeIsMicroDIN 4 The keyboard port connector type is a MicroDIN connectorPortTypelsPS2 5 The keyboard port connector type is PS 2 connectorPortTypelIsInfrared 6 The keyboard port connector type is infrared connectorPortTypeIsHPHIL 7 The keyboard port connector type is HP HIL connectorPortTypeIsDB9 8 The keyboard port connector type
135. system slot DellSystemSlotHotPlugBusWidth See Table 14 7 Read only Slot Group System Slot Hot Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 13 Description Defines the slot speed in megahertz of the hot plug system slot A zero 0 indicates that the slot speed is unknown Syntax DellUnsigned32BitRange Access Read only System Slot Hot Plug Adapter Speed Name systemSlotHot PlugAdapterSpeed Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 14 Description Defines the adapter speed in megahertz of the hot plug system slot A zero 0 indicates that the slot speed is unknown Syntax DellUnsigned32BitRange Access Read only System Slot Variable Values This section includes definitions for server administrator specific variable values used in this section Table 14 1 System Slot State Capabilities Variable Name Del 1SystemSlotStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value systemSlotHotPlugIsUnknown The system slot s capabilities are unknown 1 systemSlotHotPlugIsHotPlug The system slot supports hot plug gableCapable 2 systemSlotHotPlugCanBePower The system slot power and corresponding edon 4 light emitting diode LED can be powered on Slot Group 317 Table 14 1 System Slot State Capabilities continued Variable Name Del 1SystemSlotStateCapabilities Data Type Integer Possible Data Values
136. the variables for the eight tables that comprise the BIOS group BIOS Variable Values This section explains any Server Administrator specific variables and data types that are used in this section In the BIOS group example there are 17 unique Server Administrator specific variable meanings Information on each Server Administrator specific variable is presented in a formatted table Other Documents You May Need In addition to this Server Administrator SNMP Reference Guide you can find the following guides on your Dell Systems Management Tools and Documentation DVD e The Server Administrator Messages Reference Guide lists the messages that you can receive on your systems management console or on your operating system s event viewer This guide explains the text severity and cause of each message that the server administrator issues Server Administrator CIM Reference Guide documents the Common Information Model CIM provider an extension of the standard management object format MOF file The Server Administrator provider documents supported classes of management objects Introduction 31 Introduction to the Server Administrator SNMP Subagent This guide provides formatted information drawn primarily from the MIB files written for the Server Administrator services that support the SNMP protocol For each of the variables defined in the MIBs the following fields are specified Variable name e OID or unique identif
137. the voltage probe reading The value is an integer representing the voltage in millivolts that the probe is reading When the value for voltageProbeType is voltageProbeTypelsDiscrete a value is not returned for this attribute DellSigned32BitRange Read only Power Group 149 Voltage Probe Type Name voltageProbeType Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 7 Description Defines the type of the voltage probe Syntax DellVoltageType Access Read only Voltage Probe Location Name Name voltageProbeLocationName Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 8 Description Defines the location of the voltage probe in this chassis Syntax DellString Access Read only Voltage Probe Upper Nonrecoverable Threshold Name voltageProbeUpperNonRecoverableThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 9 Description Defines the value of the voltage probe s upper nonrecoverable threshold Syntax DellSigned32BitRange Access Read only Voltage Probe Upper Critical Threshold Name voltageProbeUpperCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 10 Description Defines the value of the voltage probe s upper critical threshold Syntax DellSigned32BitRange Access Read only 150 Power Group Voltage Probe Upper Noncritical Threshold Name Object ID Description Syntax Access voltageProbeUpperNonCriticalThreshold 1 3 6 1 4 1 674 10892 1 600 20 1 11 Defines the user assigned value of the voltage pr
138. this chassis DellObjectRange Read only Parallel Port Index Name Object ID Description Syntax Access parallelPort Index 1 3 6 1 4 1 674 10892 1 1000 70 1 2 Defines the index of the parallel ports in this chassis DellObjectRange Read only Parallel Port State Capabilities Name Object ID Description Syntax Access parallelPortStateCapabilities 1 3 6 1 4 1 674 10892 1 1000 70 1 3 Defines the capabilities of the parallel port DellStateSettings Read write PortGroup 227 Parallel Port State Settings Name parallelPortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 4 Description Defines the state and settings of the parallel port Syntax DellStateSettings Access Read write Parallel Port Status Name parallelPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 5 Description Defines the status of the parallel port Syntax DellStatus Access Read only Parallel Port Security State Name DellPortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 6 Description Defines the security state of the parallel port Syntax DellStatus Access Read only Parallel Port Connector Type Name parallelPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 7 Description Defines the connector type of the parallel port Syntax DellParallelPortConnectorlype Access Read only 228 Port Group Parallel Port Name Name Object ID Description Syntax Access parallelPortName 1 3
139. 0 67 deviceFamilyIsMIPSR4600 68 deviceFamilyIsMIPSR10000 69 deviceFamilyIsSPARC 80 deviceFamilyIsSuperSPARC 81 deviceFamilyIsmicroSPARCII 82 The processor family is Power PC 603 The processor family is Power PC 603 The processor family is Power PC 604 The processor family is Power PC 620 The processor family is Power PC x704 The processor family is Power PC 750 The processor family is Alpha The processor family is Alpha 21064 The processor family is Alpha 21066 The processor family is Alpha 21164 The processor family is Alpha 21164PC The processor family is Alpha 21164a The processor family is Alpha 21264 The processor family is Alpha 21364 The processor family is MIPS The processor family is MIPS R4000 The processor family is MIPS R4200 The processor family is MIPS R4400 The processor family is MIPS R4600 The processor family is MIPS R10000 The processor family is SPARC The processor family is SuperSPARC The processor family is microSPARC II Device Group 297 Table 13 6 Processor Device Family continued Variable Name De1 1 ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsmicroSPARCIIep The processor family is microSPARC lep 83 deviceFamilyIsUltraSPARC 84 The processor family is UltraSPARC deviceFamilyIsUltraSPARCII 85 The processor family is UltraSPARC II deviceFamilyIsUltraSPARCIIi 86
140. 0 30 1 3 Description Defines the capabilities of the processor port Syntax DellStateCapabilities Access Read only Processor Port State Settings Name processorPortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 30 1 4 Description Defines the state and settings of the processor port Syntax DellStateSettings Access Read write Processor Port Status Name processorPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 30 1 5 Description Defines the status of the processor port Syntax DellStatus Access Read only 216 Port Group Processor Port Security State Name Object ID Description Syntax Access processorPortSecurityState 1 3 6 1 4 1 674 10892 1 1000 30 1 6 Defines the security settings of the processor port DellPortSecurityState Read only Processor Port Connector Type Name Object ID Description Syntax Access processorPortConnectorType 1 3 6 1 4 1 674 10892 1 1000 30 1 7 Defines the connector type of the processor port DellProcessorPortConnectorType See Table 12 3 Read only Processor Port Name Name Object ID Description Syntax Access processorPortName 1 3 6 1 4 1 674 10892 1 1000 30 1 8 Defines name of the processor port DellString Read only Processor Port BIOS Connector Type Name Object ID Description Syntax Access processorPortBlIOSConnectorType 1 3 6 1 4 1 674 10892 1 1000 30 1 9 Defines the BIOS connector type of the processor port DellGenericPortConne
141. 0892 1 1000 10 6 Defines the security settings of the pointing port DellPortSecurityState Read only Pointing Port Connector Type Name Object ID Description Syntax Access pointingPortConnectorType 1 3 6 1 4 1 674 10892 1 1000 10 7 Defines the connector type of the pointing port DellPointingPortConnectorType See Table 12 1 Read only PortGroup 211 Pointing Port Name Name Object ID Description Syntax Access pointingPortName 1 3 6 1 4 1 674 10892 1 1000 10 8 Defines the name of the pointing port DellString Read only Pointing Port BIOS Connector Type Name Object ID Description pointingPortBIOSConnectorType 1 3 6 1 4 1 674 10892 1 1000 10 9 Defines the basic input output system BIOS connector type of the pointing port Syntax DellGenericPortConnectorlype Access Read only Keyboard Port Table Name keyboardPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 20 Description Defines the Keyboard Port Table Syntax IntegerKeyboardPortTableEntry Access Not accessible Keyboard Port Table Entry Name Object ID Description Syntax Access Index 212 keyboardPortTableEntry 1 3 6 1 4 1 674 10892 1 1000 20 1 Defines the Keyboard Port Table entry KeyboardPortTableEntry Not accessible keyboardPortchassisIndex keyboardPortIndex Port Group Keyboard Port Chassis Index Name Object ID Description Syntax Access keyboardPortchassisIndex 1 3 6 1 4 1 674 10892 1 1000 20 1 1
142. 0892 1 1100 30 1 17 Defines the number of processor cores detected for the processor device DellUnsigned32BitRange Read only Processor Device Core Enabled Count Name Object ID Description Syntax Access processorDeviceCoreEnabledCount 1 3 6 1 4 1 674 10892 1 1100 30 1 18 Defines the number of processor cores enabled for the processor device DellUnsigned32BitRange Read only Device Group 253 Processor Device Thread Count Name Object ID Description Syntax Access processorDeviceThreadCount 1 3 6 1 4 1 674 10892 1 1100 30 1 19 Defines the number of processor threads detected for the processor device DellUnsigned32BitRange Read only Processor Device Characteristics Access 254 Name Object ID Description Syntax processorDeviceCharacteristics 1 3 6 1 4 1 674 10892 1 1100 30 1 20 This attribute defines characteristics of the processor device This attribute is a bit field where a bit has the meaning defined below when set to 1 one NOTE Bits 2 15 need to be examined in the context of bit 1 If bit 1 is set the processor characteristics are unknown and bits 2 15 cannot be used to determine if the functions associated with the bits are supported Bit Position Meaning if Set Bit 0 Reserved Bit 1 Unknown Bit 2 64 bit capable Bit 3 15 Reserved DellUnsigned16BitRange Read only Device Group Processor Device Extended Capabilities Name Object ID Descri
143. 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Temperature Probe Component Status Name Object ID Description Syntax Access temperatureProbeComponentStatus 1 3 6 1 4 1 674 10893 1 20 130 11 1 13 The status of the temperature probe itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Storage Management Group 585 Temperature Probe Nexus ID Name temperatureProbeNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 14 Description Durable unique ID for this temperature probe Syntax DisplayString Access Read only Temperature Probe Connection Table This table describes the connection between each temperature probe on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table The following object sets up the Temperature Probe Connection Table Name temperatureConnectionTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 12 Description Defines the temperature probe connection table Syntax SEQUENCE OF TemperatureConnectionEntry Access Not accessible Temperature Probe Connection Entry Name temperatureConnectionEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 12 1 Description Defines the temperature probe connection table entry Syntax Te
144. 1 3 6 1 4 1 674 10892 1 1200 10 1 Description Defines the System Slot Table entry Syntax IntegerSystemSlot TableEntry Access Not accessible Index systemSlotchassisIndex systemSlotIndex Slot Group 313 System Slot Chassis Index Name Object ID Description Syntax Access System Slot Index Name Object ID Description Syntax Access systemSlotchassisIndex 1 3 6 1 4 1 674 10892 1 1200 10 1 1 Defines the index one based of this chassis DellObjectRange Read only systemSlotIndex 1 3 6 1 4 1 674 10892 1 1200 10 1 2 Defines the index one based of the system slot in this chassis DellObjectRange Read only System Slot State Capabilities Unique Name Object ID Description Syntax Access systemSlotStateCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1200 10 1 3 Defines the capabilities of the system slot DellSystemSlotStateCapabilities See Table 14 1 Read only System Slot State Settings Unique Name Object ID Description Syntax Access 314 systemSlotStateSettingsUnique 1 3 6 1 4 1 674 10892 1 1200 10 1 4 Defines the state of the system slot DellSystemSlotStateSettings See Table 14 2 Read only Slot Group System Slot Status Name Object ID Description Syntax Access systemSlotStatus 1 3 6 1 4 1 674 10892 1 1200 10 1 5 Defines the status of the system slot DellStatus Read only System Slot Current Usage Name Object ID Description Syntax Access Syste
145. 1 3 6 1 4 1 674 10892 1 1700 40 1 4 Defines the state capabilities of this remote access dial up functionality DellRemoteDialUpStateCapabilities See Table 19 22 Read only Remote Dial Up State Settings Name Object ID Description Syntax Access remoteDialUpStateSettings 1 3 6 1 4 1 674 10892 1 1700 40 1 5 Defines the state settings of this remote access dial up functionality DellRemoteDialUpStateSettings See Table 19 23 Read write Remote Access Group 457 Remote Dial Up Status Name remoteDialUpStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 6 Description Defines the status of this remote access dial up functionality Syntax DellStatus Access Read only Remote Dial Up PPP Dial In Base IP Address Name remoteDialUpPPPDialInBaseIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 7 Description Defines the base IP address of the PPP server for this remote access dial up functionality Syntax IpAddress Access Read write Remote Dial Up PPP Dial In Idle Time out Name remoteDialUpPPPDialInIdleTimeout Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 8 Description Defines the PPP idle time out value in seconds for this remote access dial up functionality Syntax DellUnsigned32BitRange Access Read write Remote Dial Up PPP Dial In Maximum Connection Time out Name remoteDialUpPPPDialInMaxConnect Timeout Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 9 Description Defines the PPP connect time out
146. 1 3 6 1 4 1 674 10893 1 20 130 9 1 9 Description Severity of the power supply state This is the combined status of the power supply and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Power Supply Nexus ID Name powerSupplyNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 10 Description Durable unique ID for this power supply Syntax DisplayString Access Read only Power Supply Revision Name powerSupplyRevision Object ID 1 3 6 1 4 1 674 10893 1 20 130 9 1 11 Description Indicates the revision number of the power supply in the enclosure Syntax DisplayString Access Read only 578 Storage Management Group Power Supply Connection Table This table describes the connection between each power supply on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table The following object sets up the Power Supply Connection Table Name Object ID Description Syntax Access powerSupplyConnectionTable 1 3 6 1 4 1 674 10893 1 20 130 10 Defines the power supply connection table SEQUENCE OF PowerSupplyConnectionEntry Not accessible Power Supply Connection Entry Name Object ID Description Syntax Access Index powerSupplyConnectionEntry 1 3 6 1 4 1 674 10893 1 20 130 10 1 Defines the power supply connection table entry Power
147. 1 4 1 674 10892 1 1700 50 1 3 Description Defines the index one based of this remote access dial in user Syntax DellObjectRange Access Read only Remote User Dial In Configuration State Capabilities Name remoteUserDialiIncfgStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 4 Description Defines the state capabilities of this remote access dial in user Syntax DellRemoteUserDiallnStateCapabilities See Table 19 25 Access Read only Remote AccessGroup__ 461 Remote User Dial In Configuration State Settings Name remoteUserDialincfgStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 5 Description Defines the state settings of this remote access dial in user Syntax DellRemoteUserDiallnStateSettings See Table 19 26 Access Read write Remote User Dial In Configuration Status Name remoteUserDialincfgStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 6 Description Defines the status of this remote access dial in user Syntax DellStatus Access Read only Remote User Dial In Configuration PPP Username Name remot eUserDial InCfgPPPUserName Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 7 Description Defines the PPP user name of this remote access dial in user Syntax DisplayString SIZE 0 15 Access Read write Remote User Dial In Configuration PPP User Password Name Name remoteUserDialiInCcfgPPPUserPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 8 Description Defines the PPP password of thi
148. 1 4 1 674 10892 1 200 10 1 42 Description Defines the combined status of all power units of this chassis Syntax DellStatus Access Read only System State Power Unit Status List Name systemStatePowerUnitStatusList Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 43 Description Lists the status of each power unit of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a power unit The first byte returned represents the status of the first power unit and so on The bytes have the same definition type as DellStatus Syntax OCTET STRING SIZE 1 128 Access Read only System State Group 59 System State Cooling Unit Status Combined Name systemStateCoolingUnitStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 44 Description Defines the combined status of all cooling units of this chassis Syntax DellStatus Access Read only System State Cooling Unit Status List Name systemStateCoolingUnitStatusList Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 45 Description Lists the status of each cooling unit of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a cooling unit The first byte returned represents the status of the first cooling unit and so on The bytes have the same definition type as DellStatus Syntax OCTET STRING SIZE 1 128 Access Read only System State AC Power Swi
149. 1 4 1 674 10893 1 20 130 12 1 5 Description Identifies the instance number of the enclosure in the enclosureTable to which this temperature probe belongs Syntax Integer Access Read only Enclosure Management Module Table This table describes available properties for each enclosure management module on the managed system The following object sets up the Enclosure Management Module Table Name enclosureManagementModuleTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 Description Defines the enclosure management module table Syntax SEQUENCE OF EnclosureManagementModuleEntry Access Not accessible Enclosure Management Module Entry Name EnclosureManagementModuleEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 13 1 Description Defines the enclosure management module table entry Syntax EnclosureManagementModuleEntry Access Not accessible Index enclosureManagementModuleNumber 588 Storage Management Group Enclosure Management Module Number Name Object ID Description Syntax Access enclosureManagementModuleNumber 1 3 6 1 4 1 674 10893 1 20 130 13 1 1 Identifies the instance number of the enclosure management module entry Integer Read only Enclosure Management Module Name Name Object ID Description Syntax Access enclosureManagementModuleName 1 3 6 1 4 1 674 10893 1 20 130 13 1 2 Identifies the enclosure management module s name as represented in Storage Management DisplayString
150. 1 400 10 1 7 Description Defines the version of the operating system running on the system Syntax DisplayString SIZE 0 255 Access Read only Operating System Memory Table Name operatingSystemMemoryTable Object ID 1 3 6 1 4 1 674 10892 1 400 20 Description Defines the Operating System Memory Table Syntax SEQUENCE OF OperatingSystemMemory TableEntry Access Not accessible Operating System Group 115 Operating System Memory Table Entry Name operatingSystemTableEntry Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 Description Defines the Operating System Memory Table entry Syntax OperatingSystemMemoryTableEntry Access Not accessible Index operatingSystemMemorychassisIndex Operating System Memory Chassis Index Name operatingSystemMemorychassisIndex Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Operating System Memory State Capabilities Name operatingSystemMemoryStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 2 Description Defines the capabilities of the operating system memory Syntax DellStateCapabilities Access Read only Operating System Memory State Settings Name operatingSystemMemoryStateSettings Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 3 Description Defines the state and allows the setting of the operating system memory Syntax DellStateSettings Access Read write 116 Operating Sy
151. 1 5 1 1 Defines the unique index for this device Unsignedl6BitRange Read only Change Management Group Device Component ID Name deviceComponent ID Object ID 1 3 6 1 4 1 674 10899 1 5 1 2 Description Defines an optional component ID field for the device Syntax Integer Access Read only Device Display String Name deviceDisplayString Object ID 1 3 6 1 4 1 674 10899 1 5 1 3 Description Provides a displayable string that describes the device Syntax DisplayString Access Read only Device Vendor ID Name deviceVendorID Object ID 1 3 6 1 4 1 674 10899 1 5 1 4 Description Defines the ID for the vendor supplying the device Syntax Octet String Access Read only Device ID Name deviceDeviceID Object ID 1 3 6 1 4 1 674 10899 1 5 1 5 Description Defines the ID for the device Syntax Octet String Access Read only Change Management Group 621 Device Sub ID Name deviceSubID Object ID 1 3 6 1 4 1 674 10899 1 5 1 6 Description Provides additional device identification Syntax Octet String Access Read only Device Sub Vendor ID Name deviceSubVendorID Object ID 1 3 6 1 4 1 674 10899 1 5 1 7 Description Provides additional vendor identification Syntax Octet String Access Read only Application Group K NOTE Dell updateable components such as Basic input output system BIOS and FirmWare FW are considered applications For example the following would be returned for system BIOS Application DisplayStri
152. 1 674 10892 1 1400 20 1 3 Description Defines the capabilities of the SCSI controller Syntax DellStateCapabilities Access Read only SCSI Control Settings Name sCSIControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 4 Description Defines the state of the SCSI controller Syntax DellStateSettings Access Read only SCSI Control Status Name scCSIControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 5 Description Defines the status of the SCSI controller Syntax DellStatus Access Read only SCSI Control Name Name sCSTControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 20 1 6 Description Defines the setup BIOS name of the SCSI controller Syntax DellString Access Read only BIOS Setup Control Group 361 Parallel Port Control Table Name parallelPortControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 30 Description Defines the Parallel Port Control Table Syntax ParallelPortControlTableEntry Access Not accessible Parallel Port Control Table Entry Name parallelPortControlTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1400 30 1 Description Defines the Parallel Port Control Table entry Syntax ParallelPortControlTableEntry Access Not accessible Index parallelPortControlchassisIndex parallel PortControllndex Parallel Port Control Chassis Index Name parallelPortControlchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 30 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange
153. 1 674 10892 1 1700 20 1 17 Description Defines the numeric pager hang up delay for this remote access user Syntax DellUnsigned32BitRange Access Read write Remote User Admin Pager Alpha Phone Number Name Name remot eUserAdminPagerAlphaPhoneNumberName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 18 Description Defines the alphanumeric pager phone number for this remote access user Syntax DisplayString SIZE 0 95 Access Read write Remote User Admin Pager Alpha Protocol Name remoteUserAdminPagerAlphaProtocol Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 19 Description Defines the protocol used by the alphanumeric pager provider for this remote access user Syntax DellRemoteUserAdminAlphaProtocolType See Table 19 16 Access Read write Remote User Admin Pager Alpha Baud Rate Name remoteUserAdminPagerAlphaBaudRate Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 20 Description Defines the baud rate used by the alphanumeric pager provider for this remote access user Syntax DellRemoteUserAdminAlphaBaudType See Table 19 17 Access Read write 448 Remote Access Group Remote User Admin Pager Alpha Custom Message Name Name remot eUserAdminPagerAlphaCustomMessageName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 21 Description Defines the message to be sent to the alphanumeric pager to inform the user of a call by this remote access user Syntax DisplayString SIZE 0 31 Access Read write Remote User Admin Pager Al
154. 1 674 10893 1 20 130 16 1 3 Identifies the instance number in the batteryTable of the battery in this connection Integer Read only Battery Connection Controller Name Name Object ID Description Syntax Access batteryConnectionControllerName 1 3 6 1 4 1 674 10893 1 20 130 16 1 4 Identifies the name of the controller as represented in Storage Management to which this battery belongs DisplayString Read only Battery Connection Controller Number Name Object ID Description Syntax Access batteryConnectionControllerNumber 1 3 6 1 4 1 674 10893 1 20 130 16 1 5 Identifies instance number of the controller in the controllerTable to which this battery belongs Integer Read only Storage Management Group 603 Logical Devices Group The Logical Devices Management Information Base MIB group provides information about the logical devices managed by the Dell Storage Management Software and their relationships to each other This group and all of its associated tables and objects are not supported on Microsoft Windows Advanced Server Limited Edition 64 bit operating system Windows Net 64 on a Dell PowerEdge 7150 The following MIB tables define objects and relationships or connections among the objects in the Logical Devices Group e Virtual Disk Table describes available properties for each virtual disk on the managed system e Array Disk Logical Connection Table describes the connec
155. 10892 1 5000 10 1 Identifies the system generating the alert DisplayString SIZE 0 255 alertTableIndexOID 1 3 6 1 4 1 674 10892 1 5000 10 2 Gives the object identifier for the index attribute in the table that contains the object causing the alert Uniquely identifies the object causing the alert and can be used to correlate different alerts caused by the same object OBJECT IDENTIFIER alertMessage 1 3 6 1 4 1 674 10892 1 5000 10 3 Describes the alert DisplayString SIZE 0 1024 Current Status Variable Name Object ID Description Syntax Previous Status Variable Name Object ID Description Syntax Data Variable Name Object ID Description Syntax alertCurrentStatus 1 3 6 1 4 1 674 10892 1 5000 10 4 Gives the current status of the object causing the alert DellStatus alert PreviousStatus 1 3 6 1 4 1 674 10892 1 5000 10 5 Gives the previous status of the object causing the alert DellStatus alertData 1 3 6 1 4 1 674 10892 1 5000 10 6 Provides Server Administrator defined data related to the alert OCTET STRING SIZE 0 1024 Traps 631 632 Understanding the Trap Description Table 25 1 lists in alphabetical order each line item that may appear in the trap description Table 25 1 Trap Description Reference Description Line Item Explanation Action performed was lt Action gt Action requested was lt Action gt Additional details lt Additio
156. 1100 30 1 12 Defines the current speed of the processor device in MHz A zero 0 indicates that the speed is unknown DellUnsigned32BitRange Read only Processor Device External Clock Speed Access Name Object ID Description Syntax processorDeviceExternalClockSpeed 1 3 6 1 4 1 674 10892 1 1100 30 1 13 Defines the speed of the external clock the front side bus speed for the processor device in MHz A zero 0 indicates that the speed is unknown DellUnsigned32BitRange Read only Processor Device Voltage Name Object ID Description Syntax Access 252 processorDeviceVoltage 1 3 6 1 4 1 674 10892 1 1100 30 1 14 Defines the voltage powering the processor device in millivolts A zero 0 indicates the speed is unknown DellSigned32BitRange Read only Device Group Processor Device Upgrade Information Name Object ID Description Syntax Access processorDeviceUpgradeInformation 1 3 6 1 4 1 674 10892 1 1100 30 1 15 Defines the processor upgrade information for the processor device DellProcessorUpgradeInformation See Table 13 5 Read only Processor Device Version Name Name Object ID Description Syntax Access processorDeviceVersionName 1 3 6 1 4 1 674 10892 1 1100 30 1 16 Defines the version name of the processor device DellString Read only Processor Device Core Count Name Object ID Description Syntax Access processorDeviceCoreCount 1 3 6 1 4 1 674 1
157. 20 130 11 1 7 Identifies the minimum temperature that will force the probe into a warning state Integer Read only Temperature Probe Minimum Critical Name Object ID Description Syntax Access temperatureProbeMinCritical 1 3 6 1 4 1 674 10893 1 20 130 11 1 8 Identifies the minimum temperature that will force the probe into an error state Integer Read only Storage Management Group 583 Temperature Probe Maximum Warning Name temperatureProbeMaxWarning Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 9 Description Identifies the maximum temperature that will force the probe into a warning state Syntax Integer Access Read only Temperature Probe Maximum Critical Name temperatureProbeMaxCritical Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 10 Description Identifies the maximum temperature that will force the probe into an error state Syntax Integer Access Read only Temperature Probe Current Value Name temperatureProbeCurValue Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 11 Description Identifies the current temperature of this probe Syntax Integer Access Read only 584 Storage Management Group Temperature Probe Roll Up Status Name Object ID Description Syntax Access temperatureProbeRollUpStatus 1 3 6 1 4 1 674 10893 1 20 130 11 1 12 Severity of the temperature probe state This is the combined status of the temperature probe and its components Possible values
158. 21 2 BMC Serial Connection Mode Settings Variable Name De1 1BMCSerialConnectionModeSettings Data Type Integer These values are bit masks therefore combination values are possible Possible Data Values Meaning of Data Value none 0 modemBasic 1 modemPPP 2 modemTerminal 4 directBasic 8 directPPP 16 directTerminal 32 No modes enabled Modem Basic mode is enabled Modem PPP mode is enabled Modem Terminal mode is enabled Direct Basic mode is enabled Direct PPP mode is enabled Direct Terminal mode is enabled Table 21 3 BMC Serial Flow Control Type Variable Name De1 1BMCSerialFlowControlType Data Type Integer Possible Data Values Meaning of Data Value none 0 rtscts 1 xonXoff 2 No flow control used RTS CTS hardware flow control used XON XOFF flow control used Baseboard Management Controller Group 499 Table 21 4 BMC Serial Bit Rate Type Variable Name De1 1BMCSerialBitRateType Data Type Integer Possible Data Values Meaning of Data Value bps9600 6 Bit rate is 9600 bps bits per second bps19200 7 Bit rate is 19200 bps bps38400 8 Bit rate is 38400 bps bps57600 9 Bit rate is 57600 bps bps115200 10 Bit rate is 115200 bps Table 21 5 BMC LAN IP Address Source Type Variable Name De 1 1BMCLANI PAddressSourceType Data Type Integer Possible Data Values Meaning of Data Value unspecified 0 Sourc
159. 3 6 1 4 1 674 10892 1 1600 30 1 5 Description Defines the duration type of the event for this system Syntax DellCOOHourDayDurationType See Table 18 2 Access Read write COO Cost Event Log Description Name Name cooCostEventLogDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 1600 30 1 6 Description Defines the name of the event description Syntax DellCostofOwnershipString Access Read write Cost of Ownership Group 407 COO Warranty Table The COO Warranty Table objects enable you to track facts about the type and duration of the warranty for a particular system Name cooWarrantyTable Object ID 1 3 6 1 4 1 674 10892 1 1600 40 Description Defines the COO Warranty Table Syntax SEQUENCE OF CooWarranty TableEntry Access Not accessible COO Warranty Table Entry Name cooWarrantyTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 Description Defines the COO Warranty Table entry Syntax CooWarranty TableEntry Access Not accessible Index cooWarrantychassisIndex cooWarrantyIndex COO Warranty Chassis Index Name cooWarrantychassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read write COO Warranty Index Name cooWarrantyIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 40 1 2 Description Defines the index of the warranty for this system Syntax DellObjectRange Access Read only 408 Cost of Ownership Group COO
160. 4 1 674 10892 1 1700 10 1 14 Description Defines the LAN capabilities of the remote access hardware Syntax DellRemoteAccessLANCapabilities See Table 19 6 Access Read only Remote Access LAN Settings Name remoteAccessLANSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 15 Description Defines the LAN settings of the remote access hardware Syntax DellRemoteAccessLANSettings See Table 19 7 Access Read write Remote Access Network Interface Controller NIC Static IP Address Name remoteAccessNICStaticIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 25 Description Defines the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read write 430 Remote Access Group Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read write Remote Access NIC Static Gateway Address Name remoteAccessNICStaticGatewayAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 27 Description Defines the IP address for the gateway associated with the static IP address to be used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read write Remote Access Personal Computer Memory Card International Assoc
161. 4 10899 1 6 1 4 Description Identifies the version of the application Syntax DisplayString Access Read only Application Display String Name applicationDisplayString Object ID 1 3 6 1 4 1 674 10899 1 6 1 5 Description A user visible display string that describes the application Syntax DisplayString Access Read only Application Sub Component ID Name applicationSubComponentID Object ID 1 3 6 1 4 1 674 10899 1 6 1 6 Description The sub component ID for the application This is usually valid on ESM device reporting Syntax DisplayString Access Read only 624 Change Management Group Operating System Group The Operating System Group provides status and identifying information about a system s operating system Identifying information includes the name version and service pack of the installed operating system The following objects describe the fields for Operating System Group Operating System Vendor Name operat ingSystemVendor Object ID 1 3 6 1 4 1 674 10899 2 1 Description Defines the vendor of the Operating System Syntax DisplayString Access Read only Operating System Major Version Name operatingSystemMajorVersion Object ID 1 3 6 1 4 1 674 10899 2 2 Description Defines the major version of the Operating System Syntax DisplayString Access Read only Operating System Minor Version Name operatingSystemMinorVersion Object ID 1 3 6 1 4 1 674 10899 2 3 Description Defines the minor version of the
162. 5 Over Voltage Warning Upper Non Warning Critical going high 131463 Over Voltage Warning Cleared Informational 131337 Over Voltage Problem Upper Critical Critical going high 131465 Over Voltage Problem Cleared Informational 131841 Generic Critical Voltage Problem Critical 131840 Generic Critical Voltage Problem Informational Cleared 668 Traps Table 25 19 BMC Traps continued TrapID Description Severity 356096 Chassis Intrusion Physical Security Critical Violation 356224 Chassis Intrusion Physical Security Informational Violation Event Cleared 262400 Generic Predictive Fan Failure Minor predictive failure asserted 262528 Generic Predictive Fan Failure Cleared Informational 262402 Generic Critical Fan Failure Critical 262530 Generic Critical Fan Failure Cleared Informational 264962 Fan redundancy has been degraded Warning 264961 Fan Redundancy Lost Critical 264960 Fan redundancy Has Returned to Normal Informational 2715392 Battery Low Predictive Failure Warning 2715520 Battery Low Predictive Failure Informational Cleared 2715393 Battery Failure Critical 2715521 Battery Failure Cleared Informational 487169 CPU Thermal Trip Over Temperature Critical Shutdown 487297 CPU Thermal Trip Over Temperature Informational Shutdown Cleared 487168 CPU Internal Error Critical 487296 CPU Internal Error Cleared Informational 487173 CPU Configuration Error Critical 487301 CPU Configur
163. 52 kilobytes KB or 2 gigabytes GB e physicalMemoryArrayTotalNumberSockets 4 the example system has four DIMM slots on the motherboard e physicalMemoryArrayInUseNumberSockets there is only one DIMM installed Memory Group 325 The following object sets up the Physical Memory Array Table Name Object ID Description Syntax Access physicalMemoryArrayTable 1 3 6 1 4 1 674 10892 1 1300 10 Defines the Physical Memory Array Table PhysicalMemoryArrayTableEntry Not accessible Physical Memory Array Table Entry Name Object ID Description Syntax Access Index physicalMemoryArrayTableEntry 1 3 6 1 4 1 674 10892 1 1300 10 1 Defines the Physical Memory Array Table entry PhysicalMemoryArrayTableEntry Not accessible physicalMemoryArraychassisIndex physicalMemoryArrayIndex Physical Memory Array Chassis Index Name Object ID Description Syntax Access physicalMemoryArraychassisIndex 1 3 6 1 4 1 674 10892 1 1300 10 1 1 Defines the index one based of this chassis DellObjectRange Read only Physical Memory Array Index Name Object ID Description Syntax Access 326 physicalMemoryArrayIndex 1 3 6 1 4 1 674 10892 1 1300 10 1 2 Defines the index one based of the physical memory array in this chassis DellObjectRange Read only Memory Group Physical Memory Array State Capabilities Name Object ID Description Syntax Access physicalMemoryArrayStateCapab
164. 6 1 4 1 674 10892 1 1000 70 1 8 Defines the name of the parallel port DellString Read only Parallel Port Connector Pin Out Name Object ID Description Syntax Access parallelPortConnectorPinOut 1 3 6 1 4 1 674 10892 1 1000 70 1 9 Defines the pinout of the parallel port DellParallelPortConnectorPinout Read only Parallel Port Capabilities Unique Name Object ID Description Syntax Access parallelPortCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1000 70 1 10 Defines the capabilities of the parallel port DellParallelPortConnectorPinout Read only Parallel Port Base I O Address Name Object ID Description Syntax Access parallelPortBaselOAddress 1 3 6 1 4 1 674 10892 1 1000 70 1 11 Defines the Base Input Output I O address of the parallel port DellUnsigned64BitRange Read only PortGroup 229 Parallel Port IRO Level Name parallelPortIRQLevel Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 12 Description Defines the Interrupt Request Level IRQ of the parallel port Syntax DellUnsigned8BitRange Access Read only Parallel Port DMA Support Name parallelPortDMASupport Object ID 1 3 6 1 4 1 674 10892 1 1000 70 1 13 Description Defines if direct memory access DMA is supported by the parallel port Syntax DellBoolean Access Read only Serial Port Table Name serialPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 80 Description Defines the Serial Port Table Syntax IntegerSerialP
165. 6 1 4 1 674 10892 1 1600 10 1 37 Defines the percentage of depreciation for this system DellUnsigned32BitRange Read write COO Depreciation Method Name Name Object ID Description Syntax Access cooDepreciationMethodName 1 3 6 1 4 1 674 10892 1 1600 10 1 38 Defines the name of the depreciation method for this system DellCostofOwnershipString Read write COO Registration Is Registered Name Object ID Description Syntax Access cooRegistrationIsRegistered 1 3 6 1 4 1 674 10892 1 1600 10 1 39 Specifies whether this system is registered or not DellBoolean Read write Cost of Ownership Group 403 COO Service Contract Table The service contract table provides MIB objects that help you track the name vendor and type of service contract you have for your system Name cooServiceContractTable Object ID 1 3 6 1 4 1 674 10892 1 1600 20 Description Defines the COO Service Contract Table Syntax SEQUENCE OF CooServiceContractTableEntry Access Not accessible COO Service Contract Table Entry Name cooServiceContractTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 Description Defines the COO Service Contract Table entry Syntax CooServiceContract TableEntry Access Not accessible Index cooServiceContractchassisIndex cooServiceContractIndex COO Service Contract Chassis Index Name cooServiceContractchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 1 Description Defines the index one ba
166. 74 10892 1 200 10 1 17 Defines the state of all cooling units in this chassis The results are returned as a binary octet string Each byte of the octet string represents the state of a specific cooling unit The first byte returned represents the state of the first cooling unit the second byte returned represents the state of the second cooling unit and so on The bytes have the same definition type as DellStateSettings OCTET STRING SIZE 1 128 Read only System State Cooling Unit Status Redundancy Name Object ID Description Syntax Access systemStateCoolingUnitStatusRedundancy 1 3 6 1 4 1 674 10892 1 200 10 1 18 Defines the state of all cooling units in this chassis DellStatusRedundancy Read only System State Cooling Unit State Details Name Object ID Description Syntax Access systemStateCoolingUnitstateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 19 Defines the state of all cooling units in this chassis The results are returned as a binary octet string Each byte of the octet string represents the state of a specific cooling unit The first byte returned represents the state of the first cooling unit the second byte returned represents the state of the second cooling unit and so on The bytes have the same definition type as DellStateSettings OCTET STRING SIZE 1 128 Read only System State Group 51 System State Cooling Device State Details Name systemStateCoolingDeviceStateDetails Obje
167. 81 Event Log Chassis Index Name event LogchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Event Log Record Index Name event LogRecordIndex Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 2 Description Defines the record index of the event log Syntax DellUnsigned32BitRange Access Read only Event Log State Capabilities Unique Name event LogStateCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 3 Description Defines the capabilities of the object that is writing the event log Syntax DellStateCapabilitiesLogUnique Access Read only Event Log State Settings Unique Name eventLogStateSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 4 Description Defines the state settings for the object that is writing the event log Syntax DellStateSettingsLogUnique Access Read write 82 Chassis Information Group Event Log Record Name Object ID Description Syntax Access event LogRecord 1 3 6 1 4 1 674 10892 1 300 40 1 5 Defines the data for the specified chassis and log record index in the event log being returned DisplayString SIZE 0 1024 Read only Event Log Format Name Object ID Description Syntax Access event LogFormat 1 3 6 1 4 1 674 10892 1 300 40 1 6 Defines the format of the event log DellLogFormat See Table 5 1 Read only Event Log Severity Status
168. 92 temperatureProbeUpperCriticalThreshold 1 3 6 1 4 1 674 10892 1 700 20 1 10 Defines the value of the temperature probe s upper critical threshold DellSigned32BitRange Read only Thermal Group Temperature Probe Upper Noncritical Threshold Name temperatureProbeUpperNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 11 Description Defines the user assigned value of the temperature probe s upper noncritical threshold Syntax DellSigned32BitRange Access Read write Temperature Probe Lower Noncritical Threshold Name temperatureProbeLowerNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 12 Description Defines the user assigned value of the temperature probe s lower noncritical threshold Syntax DellSigned32BitRange Access Read write Temperature Probe Lower Critical Threshold Name temperatureProbeLowerCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 13 Description Defines the value of the temperature probe s lower critical threshold Syntax DellSigned32BitRange Access Read only Temperature Probe Lower Nonrecoverable Threshold Name temperatureProbeLowerNonRecoverableThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 14 Description Defines the value of the temperature probe s lower nonrecoverable threshold Syntax DellSigned32BitRange Access Read only ThermalGroup 193 Temperature Probe Probe Capabilities Name Object ID Description Syntax Access
169. 92 1 1400 60 1 6 Description Defines the setup BIOS name for the IDE controller Syntax DellStatus Access Read only Diskette Control Table Name disketteControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 70 Description Defines the Diskette Control Table Syntax DisketteControl TableEntry Access Not accessible Diskette Control Table Entry Name disketteControlTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1400 70 1 Description Defines the Diskette Control Table entry Syntax DellStatus Access Not accessible Index disketteControlchassisIndex disketteControllndex 370 BIOS Setup Control Group Diskette Control Chassis Index Name Object ID Description Syntax Access disketteControlchassisIndex 1 3 6 1 4 1 674 10892 1 1400 70 1 1 Defines the index one based of this chassis DellObjectRange Read only Diskette Control Index Name Object ID Description Syntax Access disketteControlIndex 1 3 6 1 4 1 674 10892 1 1400 70 1 2 Defines the index of the diskette controllers in this chassis DellObjectRange Read only Diskette Control Capabilities Unique Name Object ID Description Syntax Access disketteControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1400 70 1 3 Defines the capabilities of the diskette controller DellDisketteControlCapabilitiesUnique See Table 16 18 Read only Diskette Control Settings Unique Name Object ID Description Syntax Access disketteControlSettingsUnique
170. 92 1 500 60 1 7 Defines the share disposition of the system resource DMA DellResourceShareDisposition See Table 7 3 Read only System Resource DMA Maximum Transfer Size Name Object ID Description Syntax Access systemResourceDMAMaximumTransferSize 1 3 6 1 4 1 674 10892 1 500 60 1 8 Defines the maximum size of a memory transfer in bytes for the system resource DMA DellUnsigned32BitRange Read only System Resource DMA Transfer Width Name Object ID Description Syntax Access systemResourceDMATransferWidth 1 3 6 1 4 1 674 10892 1 500 60 1 9 Defines the transfer width of the system resource DMA DellResourceDMATransferWidth See Table 7 8 Read only System Resource Group 135 System Resource DMA Bus Master Name systemResourceDMABusMaster Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 10 Description Defines the bus mastering capabilities of the system resource DMA Syntax DellResource DMABusMaster See Table 7 7 Access Read only System Resource Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 7 1 System Resource Map Type Variable Name De1 1SystemResourceMapType Data Type Integer Possible Data Values Meaning of Data Value other 1 The system resource map type is not one of the following unknown 2 The system resource map type is unknown not known or not monitored typeOne 3
171. Access NIC Static Gateway Address Name Object ID Description Syntax Access remoteAccessNICStaticGatewayAddress 1 3 6 1 4 1 674 10892 1 1700 10 1 27 Defines the IP address for the gateway associated with the static IP address to be used by the integrated NIC provided by the remote access hardware IpAddress Read write Remote Access Personal Computer Memory Card International Association PCMCIA Info Name Name Object ID Description Syntax Access remoteAccessPCMCIAInfoName 1 3 6 1 4 1 674 10892 1 1700 10 1 28 Defines the information for the PCMCIA device used by the remote access hardware DisplayString SIZE 0 63 Read only Remote Access Miscellaneous Information Name Name Object ID Description Syntax Access remoteAccessMiscInfoName 1 3 6 1 4 1 674 10892 1 1700 10 1 29 Defines the miscellaneous information for the remote access hardware DisplayString SIZE 0 63 Read write Remote AccessGroup__ 441 Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read only Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 31 Description Defines the netmask currently being used by the
172. Alert Reference lets you monitor the NA health of storage resources such as controllers connectors array disks and virtual disks 22 Introduction Server Administrator Change Management MIB The Server Administrator Change Management MIB filename dellcm mib provides management data that allows you to monitor the inventory of devices and applications with SNMP management applications Table 1 6 describes each Server Administrator Change Management MIB group and lists the MIB group number assigned to the MIB group The Server Administrator Change Management MIB groups are identified by the SNMP OID 1 3 6 1 4 1 674 lt MIB group number gt where lt MIB group number gt is the MIB group number assigned to the MIB group See the relevant section for more information about the MIB objects defined in a MIB group Table 1 6 Server Administrator Change Management MIB Sections in This Guide Section Topics MIB Group Number 24 Change Management Group describes the inventory 10899 data provided by the Change Management MIB that allows users to monitor devices and software present on a particular managed computer chassis How This Guide Defines Technical Terms The following table provides information about where to find definitions for technical terms in this reference guide Table 1 7 Where to Find Definitions for Technical Terms Type of Definition See Basic SNMP vocabulary Introduction MIB group specific variab
173. Array ECC Error Noncritical Threshold Name Object ID Description Syntax Access physicalMemoryArrayECCErrorNonCriticalThreshold 1 3 6 1 4 1 674 10892 1 1300 10 1 14 Defines the value of the physical memory array ECC error noncritical threshold DellSigned32BitRange read write MemoryGroup__ 329 Physical Memory Array Redundant Memory Unit Index Reference Name Object ID Description Syntax Access physicalMemoryArrayRedundantMemoryUnit Index Reference 1 3 6 1 4 1 674 10892 1 1300 10 1 15 Defines the index to the associated Redundant Memory Unit in this chassis DellObjectRange Read only Physical Memory Array Mapped Table The physical memory array is divided into memory array mapped addresses The following object sets up the Physical Memory Array Mapped Table Name Object ID Description Syntax Access physicalMemoryArrayMappedTable 1 3 6 1 4 1 674 10892 1 1300 20 Defines the Physical Memory Array Mapped Table PhysicalMemoryArrayMappedTableEntry Not accessible Physical Memory Array Mapped Table Entry Name Object ID Description Syntax Access Index 330 PhysicalMemoryArrayMappedTableEntry 1 3 6 1 4 1 674 10892 1 1300 20 1 Defines the Physical Memory Array Mapped Table entry PhysicalMemoryArrayMappedTableEntry Not accessible physicalMemoryArrayMappedchassisIndex physicalMemoryArrayMappedIndex Memory Group Physical Memory Array Mapped Chassis Index Name
174. BitRange Read write Cost of Ownership Group 411 COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 6 Description Defines the rate factor for the lease on this system Syntax DellUnsigned32BitRange Access Read write COO Lease Information End Date Name Name cooLeaseInformationEndDateName Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 7 Description Defines the end date for the lease on this system Syntax DellDateName Access Read write COO Lease Information Fair Market Value Name cooLeaseInformationFairMarketValue Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 8 Description Defines the fair market value of this system Syntax DellUnsigned32BitRange Access Read write COO Lease Information Lessor Name Name cooLeaseInformationLessorName Object ID 1 3 6 1 4 1 674 10892 1 1600 50 1 9 Description Defines the name of the lessor of this system Syntax DellCostofOwnershipString Access Read write 412 Cost of Ownership Group COO Schedule Number Table Name Object ID Description Syntax Access cooScheduleNumberTable 1 3 6 1 4 1 674 10892 1 1600 60 Defines the COO Schedule Number Information Table SEQUENCE OF CooScheduleNumberTableEntry Not accessible COO Schedule Number Table Entry Name Object ID Description Syntax Access Index cooScheduleNumberTableEntry 1 3 6 1 4 1 674 10892 1 1600 60 1 Defines the COO Schedule Number
175. C Syntax OCTET STRING SIZE 16 Access Read only BMC Type Name bmcType Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 10 Description Defines the type of the BMC Syntax DellManagementControllerlype Access Read only BMC Module Name Name bmcModuleName Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 11 Description Defines the module name for the BMC The module name is present only on certain systems such as modular systems Syntax DellString Access Read only 490 Baseboard Management Controller Group Baseboard Management Controller Serial Interface Table Name bmcSerialInterfaceTable Object ID 1 3 6 1 4 1 674 10892 1 1900 20 Description Defines the BMC Serial Interface Table Syntax SEQUENCE OF BmcSeriallnterfaceTableEntry Access Not accessible BMC Serial Interface Table Entry Name bmcSerialInterfaceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 Description Defines the BMC Serial Interface Table Entry Syntax BmcSeriallnterfaceTableEntry Access Not accessible Index bmcSeriallnterfaceChassisIndex bmcSeriallnterfaceBMCIndex bmcSerialInterfaceIndex BMC Serial Interface Chassis Index Name bmcSerialInterfaceChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 1 Description Defines the index one based of the associated chassis Syntax DellObjectRange Access Read only BMC Serial Interface BMC Index Name bmcSerialInterfaceBMCIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 2 Description
176. CSI array disks their channel and their associated controller For each object in the table its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found Fan Table describes available properties for each fan on the managed system Fan Connection Table describes the connection between each fan on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table Power Supply Table describes available properties for each power supply on the managed system Power Supply Connection Table describes the connection between each power supply on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table Storage Management Group e Temperature Probe Table describes available properties for each temperature probe on the managed system Temperature Probe Connection Table describes the connection between each temperature probe on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table e EMM Table describes available properties for each Enclosure Management Module EMM on the managed system e EMM Connection Table describes the connection between each EMM on the managed system and its enclosure Each enclosure numb
177. Capabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The SNMP trap destination has no state capabilities unknownCapabilities The SNMP trap destination state capabilities 1 are unknown enableCapable 2 The SNMP trap destination can be disabled or enabled notReadyCapable 4 The SNMP trap destination can be in the not ready state Table 19 19 Remote SNMP Trap State Settings Variable Name De1 LRemoteSNMPTrapStateSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The SNMP trap destination has no state settings unknown 1 The SNMP trap destination state settings are unknown enabled 2 The SNMP trap destination is enabled notReady 4 The SNMP trap destination is in the not ready state Remote Access Group 475 Table 19 20 Remote SNMP Trap Control Capabilities Variable Name De1 LRemoteSNMPTrapControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The SNMP trap destination has no control capabilities unknownCapabilities The SNMP trap destination control capabilities are 1 unknown trapTestCapable 2 ASNMP trap test can be performed for the SNMP trap destination Table 19 21 Remote SNMP Trap Control Settings Variable Name De1 LRemoteSNMPTrapControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The SNMP trap destination has no con
178. CprocessorSerialNumberControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 13 Description Defines the setup BIOS name of the processor serial number Syntax DellString Access Read write BIOS Setup Control Speaker Control Capabilities Unique Name bsSUCspeakerControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 14 Description Defines the capabilities of the speaker control Syntax DellSpeakerControlCapabilitiesUnique See Table 16 1 Access Read only BIOS Setup Control Speaker Control Settings Unique Name bsSUCspeakerControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 15 Description Defines the settings available for speaker control Syntax DellSpeakerControlSettingsUnique See Table 16 2 Access Read only BIOS Setup Control Group 353 BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 16 Description Defines the status of speaker control Syntax DellStatus Access Read only BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 17 Description Defines the setup BIOS name of the speaker control Syntax DellString Access Read only BIOS Setup Control NIF Wakeup on LAN Control Capabilities Unique Name bsuCnI FwakeonLanControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 18 Description Defines the defines the capabilities of the network interface
179. D 1 3 6 1 4 1 674 10892 1 1 3 0 Description Defines the maintenance version number for the version of this MIB supported by the systems management software For example if the MIB version is 1 2 3 the maintenance version number is 3 Syntax DellUnsigned8BitRange Access Read only 38 Instrumentation MIB Version Group Systems Management Software Group The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis The Systems Management Software Group classifies each computer chassis according to the systems management standard that the agent supports Additional objects define the universal resource locator URL of the systems management software and the language in which systems management information displays Defining these objects enables users to manage a system using an internet browser You can access Server Administrator using the secure hypertext transfer protocol https and a pre assigned port number of 1311 or you can specify a port number of your own choosing K NOTE Using the Software Server Preferences menu of Server Administrator you can bind to either one IP address or to all IP addresses K NOTE To manage a system remotely using Server Administrator type one of the following in the address field of your browser https lt systemname gt lt 1311 or user specified port number gt or
180. D 1 3 6 1 4 1 674 10893 1 20 130 4 1 34 Description The four digit year in which this disk was manufactured Syntax DisplayString Access Read only Array Disk Enclosure Connection Table This table describes the connections among array disks their enclosure and their associated controller For each object in the table its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found K NOTE Only array disks that are part of an enclosure will be listed in this table Backplanes are considered enclosures by Storage Management The following object sets up the Array Disk Enclosure Connection Table Name arrayDiskEnclosureConnectionTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 Description Defines the array disk enclosure connection table Syntax SEQUENCE OF ArrayDiskEnclosureConnectionEntry Access Not accessible Array Disk Enclosure Connection Entry Name arrayDiskEnclosureConnectionEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 Description Defines the array disk enclosure connection table entry Syntax ArrayDiskEnclosureConnectionEntry Access Not accessible Index arrayDiskEnclosureConnectionNumber Storage Management Group 561 Array Disk Enclosure Connection Number Name arrayDiskEnclosureConnectionNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 1 Description Identifies the instance number of the array disk enclosure
181. DRAM that is faster than conventional DRAM EDO RAM can start fetching the next block of memory at the same time that it sends the previous block to the CPU EEPROM Acronym for electrically erasable programmable read only memory Glossary 697 EIDE Abbreviation for enhanced integrated drive electronics EIDE devices add one or more of the following enhancements to the traditional IDE standard Data transfer rates of up to 16 MB sec Support for drives other than just hard drives such as CD and tape drives Support for hard drives with capacities greater than 528 MB Support for up to two controllers each with up to two devices attached EISA Acronym for Extended Industry Standard Architecture a 32 bit expansion bus design The expansion card connectors in an EISA computer are also compatible with 8 or 16 bit ISA expansion cards To avoid a configuration conflict when installing an EISA expansion card you must use the EISA Configuration Utility This utility allows you to specify which expansion slot contains the card and obtains information about the card s required system resources from a corresponding EISA configuration file EMC Abbreviation for Electromagnetic Compatibility EMI Abbreviation for electromagnetic interference EMM Abbreviation for expanded memory manager A utility that uses extended memory to emulate expanded memory on computers with an Intel386 or higher microprocessor EMS Abbreviation for E
182. Dates Variable Name De 1 1 Dat eName Data Type DisplayString DisplayString SIZE 25 Full dates are defined in the ASCII format yyyyMMddhhmmss uuuuuu fff or yyyyMMddhhmmss uuuuuu fff where yyyy is the year MM is the month dd is the day hh are the hours mm are the minutes and ss are the seconds uuuuuu is the number of microseconds and fff or fff is the offset from UTC in minutes For example Friday October 31 2001 at 6 05 19 PM CST would be represented as 20011031180519 000000 360 The values are zero padded and if a valid value for a field is not deliverable each character in the field will be replaced with an asterisk character 682 Standard Data Type Definitions SNMP Sample Output This sample output from the Simple Network Management Protocol SNMP covers the first four groups of the Instrumentation management information base MIB Values are shown for each object identifier OID in the Instrumentation MIB Version Group the Systems Management Software Group the System State Group the Chassis Information Table and Event Log Table The data is from a Dell PowerEdge 2650 system Walk 1 3 6 1 4 1 674 10892 Agent SERVERO1 Community public iso org dod internet private enterprises dell server3 1 3 6 1 4 1 674 10892 1 1 1 T3 n A A 4 1 4 1 674 10892 1 1 2 4 1 3 6 1 4 1 674 10892 1 1 3 j m O fo ll o 1 3 6 1 4 1 674 10892 1 100 Administrator nO S
183. Defines the mode capabilities of the parallel port Syntax DellParallelPortControlModeCapabilitiesUnique See Table 16 14 Access Read only Parallel Port Control Mode Settings Unique Name parallelPortControlModeSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 30 1 8 Description Defines the mode settings of the parallel port Syntax DellParallelPortControlModeSettingsUnique See Table 16 14 Access Read write Serial Port Control Table Name serialPortControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 40 Description Defines the Serial Port Control Table Syntax SerialPortContro TableEntry Access Not accessible Serial Port Control Table Entry Name serialPortControlTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 Description Defines the Serial Port Control Table entry Syntax SerialPortControlTableEntry Access Not accessible Index serialPortControlchassisIndex serialPortControllndex 364 BIOS Setup Control Group Serial Port Control Chassis Index Name serialPortControlchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 1 Description Defines index one based of this chassis Syntax DellObjectRange Access read only Serial Port Control Index Name serialPortControlIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 2 Description Defines the index one based of the serial port in this chassis Syntax DellObjectRange Access read only Serial Port Control Capabilities Unique Name serialPortCon
184. Dell OpenManage Server Administrator Version 5 4 SNMP Reference Guide www dell com support dell com Notes and Notices K NOTE A NOTE indicates important information that helps you make better use of your computer NOTICE A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem Information in this document is subject to change without notice 2003 2008 Dell Inc All rights reserved Reproduction in any manner whatsoever without the written permission of Dell Inc is strictly forbidden Trademarks used in this text Dell the DELL logo PowerEdge PowerVault and OpenManage are trademarks of Dell Inc Microsoft Windows and Windows NT are registered trademarks of Microsoft Corporation Intel Itanium Pentium and Celeron are registered trademarks and MMX Xeon Core and Intel386 are trademarks of Intel Corporation UNIX is a registered trademark of The Open Group in the United States and in other countries VESA is a registered trademark of the Video Electronics Standards Association AMD AMD Athlon AMD Opteron AMD Sempron AMD Turion and AMD Duron are trademarks of Advanced Micro Devices Inc Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Dell Inc disclaims any proprietary interest in trademarks and trade names other than its own January 2008 Contents 1 Intr
185. Description Defines the capabilities of the monitor port Syntax DellStateCapabilities Access Read only Monitor Port State Settings Name monitorPortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 4 Description Defines the state of the monitor port Syntax DellStateSettings Access Read write Monitor Port Status Name monitorPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 5 Description Defines the status of the monitor port Syntax DellStatus Access Read only 222 Port Group Monitor Port Security State Name monitorPortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 6 Description Defines the security settings of the monitor port Syntax DellPortSecurityState Access Read only Monitor Port Connector Type Name monitorPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 7 Description Defines the connector type of the monitor port Syntax DellMonitorPortConnectorTypes See Table 12 5 Access Read only Monitor Port Name Name monitorPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 8 Description Defines the name of the monitor port Syntax DellString Access Read only Monitor Port BIOS Connector Type Name monitorPortBlOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 9 Description Defines the name of the BIOS connector type of the monitor port Syntax DellGenericPortConnectorType Access Read only PortGroup 223 Small Computer System Interface SCSI Port
186. DeviceRDMACapabilityFlags 1 3 6 1 4 1 674 10892 1 1100 90 1 25 Defines the Remote Direct Memory Access RDMA capability flags of the network device DellNetworkDeviceRDMACapabilityFlags see Table 13 23 Read only Network Device RDMA Enabled Name Object ID Description Syntax Access networkDeviceRDMAEnabled 1 3 6 1 4 1 674 10892 1 1100 90 1 26 Defines if RDMA is enabled for the network device DellBoolean Read only Network Device iSCSI Capability Flags Name Object ID Description Syntax Access networkDeviceiSCSICapabilityFlags 1 3 6 1 4 1 674 10892 1 1100 90 1 27 Defines the Internet Small Computer System Interface iSCSI capability flags of the network device DellNetworkDeviceiSCSICapabilityFlags see Table 13 24 Read only Network Device iSCSI Enabled Name Object ID Description Syntax Access networkDeviceiSCSIEnabled 1 3 6 1 4 1 674 10892 1 1100 90 1 28 Defines if iSCSI is enabled for the network device DellBoolean Read only Device Group 291 Device Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 13 1 Pointing Device Type Variable Name De11PointingDeviceType Data Type Integer Possible Data Values Meaning of Data Value deviceTypelIsOther 1 deviceTypelIsUnknown 2 deviceTypelIsAMouse 3 deviceTypelIsATrackBall 4 deviceTypelIsATrackPoint 5 dev
187. Discrete a value is not returned for this attribute When the value for voltageProbeType is voltageProbeTypelsDiscrete the value returned for this attribute is the discrete reading for the probe Syntax DellVoltageDiscreteReading Access Read only Amperage Probe Table Name amperageProbeTable Object ID 1 3 6 1 4 1 674 10892 1 600 30 Description Defines the Amperage Probe Table Syntax SEQUENCE OF AmperageProbeTableEntry Access Not accessible 152 Power Group Amperage Probe Table Entry Name Object ID Description Syntax Access Index amperageProbeTableEntry 1 3 6 1 4 1 674 10892 1 600 30 1 Defines the Amperage Probe Table entry AmperageProbeTableEntry Not accessible amperageProbechassisIndex amperageProbeIndex Amperage Probe Chassis Index Name Object ID Description Syntax Access amperageProbechassisIndex 1 3 6 1 4 1 674 10892 1 600 30 1 1 Defines the index one based of this chassis DellObjectRange Read only Amperage Probe Index Name Object ID Description Syntax Access amperageProbeIndex 1 3 6 1 4 1 674 10892 1 600 30 1 2 Defines the index of amperage probes in this chassis DellObjectRange Read only Amperage Probe State Capabilities Name Object ID Description Syntax Access amperageProbeStateCapabilities 1 3 6 1 4 1 674 10892 1 600 30 1 3 Defines the capabilities of the amperage probe DellStateCapabilities Read only Power Group 153 Amperage Probe S
188. DisplayString Access Read only Channel Bus Type Name channelBusType Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 11 Description The bus type of the channel Possible values 1 SCSI 2 IDE 3 Fibre Channel 4 Serial Storage Architecture SSA 6 Universal Serial Bus USB 7 8 SATA SAS Syntax Integer Access Read only 538 Storage Management Group Enclosure Table This table describes available properties for each enclosure on the managed system The following object sets up the Enclosure Table Name enclosureTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 Description Defines the enclosure table Syntax SEQUENCE OF EnclosureEntry Access Not accessible Enclosure Entry Name enclosureEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 Description Defines the enclosure table entry Syntax EnclosureEntry Access Not accessible Index enclosureNumber Enclosure Number Name enclosureNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 1 Description Identifies the instance number of the enclosure entry Syntax Integer Access Read only Storage Management Group 539 Enclosure Name Name enclosureName Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 2 Description Identifies the enclosure s name as represented in Storage Management Syntax DisplayString Access Read only Enclosure Vendor Name enclosureVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 3 Description Identifies the enclosure s re
189. Group COO Deployment Date Length Name cooDeploymentDateLength Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 20 Description Defines the deployment time for this system Syntax DellUnsigned32BitRange Access Read write COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 21 Description Defines the deployment time units for this system Syntax DellCooHourDayDuration Type See Table 18 2 Access Read write C00 Training Name Name cooTrainingName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 22 Description Defines the training that the user has for this system Syntax DellCostofOwnershipString Access Read write COO Outsourcing Problem Description Name Name cooOutsourcingProblemDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 23 Description Defines a problem encountered with the outsourcing service provider Syntax DellCostofOwnershipString Access Read write Cost of Ownership Group 399 COO Outsourcing Service Fee Name Name Object ID Description Syntax Access cooOut sourcingServiceFeeName 1 3 6 1 4 1 674 10892 1 1600 10 1 24 Defines amount that the outsourcing vendor charges for service DellCostofOwnershipString Read write COO Outsourcing Signing Authority Name Name Object ID Description Syntax Access cooOut sourcingSigningAuthorityName 1 3 6 1 4 1 674 10892 1 1600 10 1 25 Defines the name of the person who can sign the au
190. Group Location Event Name Object ID Description Syntax Access locationEvent 1 3 6 1 4 1 674 10893 1 20 200 3 Additional information identifying the location of the object causing the alert DisplayString Read only Object Name Event Name Object ID Description objectNameEvent 1 3 6 1 4 1 674 10893 1 20 200 4 Name of the object as represented in Storage Management causing the alert Syntax DisplayString Access Read only Object OID Event Name objectOIDEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 5 Description MIB OID of the object causing the alert Syntax DisplayString Access Read only Object Nexus Event Name Object ID Description Syntax Access obj ectNexusEvent 1 3 6 1 4 1 674 10893 1 20 200 6 Durable unique ID of the object causing the alert DisplayString Read only Storage Management Group 617 Current Status Event Name currentStatusEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 7 Description Current status of object causing the alert if applicable Syntax DellStatus Access Read only Previous Status Event Name previousStatusEvent Object ID 1 3 6 1 4 1 674 10893 1 20 200 8 Description Previous status of object causing the alert if applicable Syntax DellStatus Access Read only 618 Storage Management Group Change Management Group The Change Management Group lets you monitor information about the Dell devices and software that are present on
191. Hour Day Duration Type Variable Name De 11 CooHourDayDurationType Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Duration time type is unknown hours 2 Duration time type is in hours days 3 Duration time type is in days Table 18 3 COO Day Month Duration Type Variable Name De11CooDayMonthDurationType Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Duration time type is unknown days 3 Duration time type is in days months 4 Duration time type is in months Table 18 4 COO Month Year Duration Type Variable Name De 11 CooMonthYearDurationType Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Duration time type is unknown months 4 Duration time type is in months years 5 Duration time type is in years Cost of Ownership Group 425 426 Cost of Ownership Group Remote Access Group The Remote Access Group provides information about the remote access hardware that may be present in your system In addition to providing general information about the capabilities and settings of the remote access hardware this group provides information about administrative users SNMP trap destinations modem configuration for dial up networking dial in configuration and dial out destinations DRAC 4 and DRAC 5 On systems with Dell Remote Access Controller DRAC 4 or DRAC 5 the Remote Access Gr
192. IB Maintenance Version Number tems Management Software GROUND ne hoy aan a an Se Seek Contents Systems Management Software Systems Management Software Name Systems Management Software Version Number Name Systems Management Software Build Number noaa auaa aaa Systems Management Software Description Name aaa aaa Systems Management Software Supported Protocol Systems Management Software Preferred Protocol Systems Management Software Update Level Name Systems Management Software URL Name noi s ee ee ee ea ee eS Systems Management Software Language Name 004 42 Systems Management Software Global VersionName 42 Systems Management Software Feature Flags 2 2 eee eee 42 Systems Management Software SNMP Agent Feature Flags 43 Systems Management Software ManufacturerName 43 Systems Management Software Variable Values 43 4 System State Group 45 System StateGroupTable 45 System StateTable 45 5 Chassis Information Group 65 Chassis Information Group Tables 65 Chassis Information Table 65 WUID Table 2 2 eee ee ea eee eee 77 POSTLogTable 79 EventLogTable 81 System BIOS Table 84 Firmware Table
193. ID 1 3 6 1 4 1 674 10892 1 100 4 Description Defines the description of the systems management software Syntax DellString Access Read only Systems Management Software Supported Protocol Name systemManagementSoftwareSupportedProtocol Object ID 1 3 6 1 4 1 674 10892 1 100 5 Description Defines the systems management standards SNMP or CIM supported by the systems management software Syntax SMSSupportedTypes See Table 3 1 Access Read only Systems Management Software Preferred Protocol Name systemManagementSoftwarePreferredProtocol Object ID 1 3 6 1 4 1 674 10892 1 100 6 Description Defines the preferred systems management standard for the systems management software Syntax SMSSupported Types See Table 3 1 Access Read only Systems Management Software Update Level Name Name systemManagementSoftwareUpdateLevelName Object ID 1 3 6 1 4 1 674 10892 1 100 7 Description Defines the update level of the system management software Syntax DellString Access Read only Systems Management Software Group 41 Systems Management Software URL Name Name systemManagementSoftwareURLName Object ID 1 3 6 1 4 1 674 10892 1 100 8 Description Defines the universal resource locator URL of the systems management software Syntax DisplayString SIZE 0 1024 Access Read only Systems Management Software Language Name Name systemManagement SoftwareLanguageName Object ID 1 3 6 1 4 1 674 10892 1 100 9 Description Defines th
194. IP Address Name Object ID Description Syntax Access networkDeviceDHCPServer IPAddress 1 3 6 1 4 1 674 10892 1 1100 90 1 14 Defines the IP address of the DHCP server that was used to obtain the IP address of the network device if DHCP was used to configure the network device IpAddress Read only Network Device Current MAC Address Name Object ID Description Syntax Access networkDeviceCurrentMACAddress 1 3 6 1 4 1 674 10892 1 1100 90 1 15 Defines the current MAC address of the network device DelIMACAdadress Read only Network Device Permanent MAC Address Name Object ID Description Syntax Access 288 networkDevicePermanentMACAddress 1 3 6 1 4 1 674 10892 1 1100 90 1 16 Defines the permanent MAC address of the network device DelIMACAddress Read only Device Group Network Device PCI Bus Number Name networkDevicePCIBusNumber Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 17 Description Defines the PCI bus number of the network device Syntax DellUnsigned8BitRange Access Read only Network Device PCI Device Number Name networkDevicePCIDeviceNumber Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 18 Description Defines the PCI device number of the network device Syntax DellUnsigned8BitRange Access Read only Network Device PCI Function Number Name networkDevicePCIFunctionNumber Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 19 Description Defines the PCI function number of the network
195. Information Group Intrusion Reading Name intrusionReading Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 6 Description Defines the reading of the intrusion object Syntax DellIntrusionReading Access Read only Intrusion Type Name intrusionType Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 7 Description Defines the type of the intrusion object Syntax DellIntrusionType Access Read only Intrusion Location Name Name intrusionLocationName Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 8 Description Defines the location name of the intrusion object in this subgroup Syntax DellString Access Read only Baseboard Table This table lists objects that define the baseboard of a system Name baseBoardTable Object ID 1 3 6 1 4 1 674 10892 1 300 80 Description Defines the Baseboard Table Syntax SEQUENCE OF BaseBoard TableEntry Access Not accessible Chassis Information Group 95 Baseboard Table Entry Name baseBoardTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 Description Defines the Baseboard Table entry Syntax BaseBoard TableEntry Access Not accessible Index baseBoardChassisIndex baseBoardIndex Baseboard Chassis Index Name baseBoardChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 1 Description Defines the index one based of the associated chassis Syntax DellObjectRange Access Read only Baseboard Index Name baseBoardIndex Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 2 Description Defines the
196. Information Table entry CooScheduleNumberTableEntry Not accessible cooScheduleNumberchassisIndex cooScheduleNumberIndex COO Schedule Number Chassis Index Name Object ID Description Syntax Access cooScheduleNumberchassisIndex 1 3 6 1 4 1 674 10892 1 1600 60 1 1 Defines the index one based of this chassis DellObjectRange Read only COO Schedule Number Index Name Object ID Description Syntax Access cooScheduleNumber Index 1 3 6 1 4 1 674 10892 1 1600 60 1 2 Defines the index of the schedule number information DellObjectRange Read only Cost of Ownership Group 413 COO Schedule Number State Name cooScheduleNumberState Object ID 1 3 6 1 4 1 674 10892 1 1600 60 1 3 Description Defines the schedule number information state of this system Syntax DellStateSettings Access Read only COO Schedule Number Lease Information Index Reference Name cooScheduleNumberLeaseInformationIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1600 60 1 4 Description Defines the lease information index number to reference the schedule number Syntax DellUnsigned32BitRange Access Read write COO Schedule Number Description Name Name cooScheduleNumberDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 1600 60 1 5 Description Describes the schedule number information Syntax DellCostofOwnershipString Access Read write COO Options Table Name cooOptionsTable Object ID 1 3 6 1 4 1 674 10892 1 1600 70 De
197. Integer Access Read only Controller Name Name controllerName Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 2 Description Identifies the name of the controller in this subsystem as represented in Storage Management Includes the controller type and instance For example PERC 3 QC 1 Syntax DisplayString Access Read only 518 Storage Management Group Controller Vendor Name controllerVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 3 Description Identifies the controller s re seller s name Syntax DisplayString Access Read only Controller Type Name controllerType Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 4 Description Identifies the type of this controller 1 SCSI 2 PowerVault 660F 3 Power Vault 662F 4 Integrated Intelligent Drive Electronics IDE 5 Serial Advanced Technology Architecture SATA 6 Serial Attached SCSI SAS Syntax Integer Access Read only Storage Management Group 519 Controller State Name controllerState Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 5 Description Identifies the status of the controller s subsystem which includes any devices connected to it Possible states 0 Unknown 1 Ready 2 Failed 3 Online 4 Offline 6 Degraded Syntax Integer Access Read only Controller Severity Name controllerSeverity Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 6 Description This entry is obsolete for Storage Management It was replaced with RollUpStatus a
198. L probe The voltage pro be type is a voltage probe with discrete reading 174 Power Group Table 8 7 Voltage Probe Discrete Reading Variable Name De1 1VoltageDiscreteReading Data Type Integer Possible Data Values Meaning of Data Value voltageIsGood voltageIsBad 2 1 The voltage probe discrete reading is good The voltage probe discrete reading is bad Table 8 8 Amperage Probe Definitions Variable Name De1 1AmperageType Data Type Integer Possible Data Value Ss Meaning of Data Value amperageProbel amperageProbel amperageProbel amperageProbel amperageProbel amperageProbel amperageProbel amperageProbel amperageProbel ypeIsOther 1 ypeIsUnknown 2 TypeIslPoint5Volt 3 TypeIs3Point3volt 4 TypeIs5Volt 5 TypeIsMinus5Volt 6 TypeIs1l2Volt 7 TypeIsMinus12Volt 8 rypeIsIO 9 amperageProbel ypeIsCore 10 The amperage probe type is not one of the following The amperage probe type is unknown not known or not monitored The amperage probe type is a 1 5 ampere A probe The amperage probe type is a 3 3 A probe The amperage probe type is a 5 A probe The amperage probe type is a 5 A probe The amperage probe type is a 12 A probe The amperage probe type is a 12 A probe The amperage probe type is an T O amperage probe The amperage probe type is a core amperage probe
199. M 14 The memory device port connector type is a Rambus Inline Memory Module RIMM The memory device port connector type is a small outline dual in line memory module SODIMM The memory device port connector type is a SRIMM Table 12 5 Monito r Port Connector Types Variable Name De1 LMonitorPortConnectorType Data Type Integer Possible Data Values Meaning of Data Value connectorPortTypelIsOther 1 connectorPortTypelIsUnknown 2 connectorPorti TypeIsDB15PinMale 3 connectorPorti rypeIsDB15PinFemale 4 The monitor port connector type is not one of the following The monitor port connector type is unknown The monitor port connector type isa male DB 15 The monitor port connector type is a female DB 15 PortGroup 241 Table 12 6 SCSI Port Connector Types Variable Name De11SCSTPortConnectorType Data Type Integer Possible Data Values Meaning of Data Value connectorPortTypelsOther 1 The SCSI port connector type is not one of the following connectorPortTypelIsUnknown 2 The SCSI port connector type is unknown connectorPortTypeIsDIN25pin 3 The SCSI port connector type is a DIN 25 pin connectorPortTypeIsDIN50pin 4 The SCSI port connector type is a DIN 50 pin 4 connectorPortTypeIsDIN68pin 5 he SCSI port connector type is a DIN 68 pin 242 Port Group Device Group The Device Group provides informatio
200. Meaning of Data Value device devicel devicel devicel LevelIsOther 1 Level IsUnknown 2 LevelIsPrimary 3 LevelIsSecondary 4 device LeveliIsTertiary 5 Device level is not one of the following Device level is unknown Device level is primary Device level is secondary Device level is tertiary Table 13 9 Cache Device Write Policy Variable Name De 1 1CacheDeviceWritePolicy Data Type Integer Possible Data Values Meaning of Data Value deviceWritePolicyIsOther 1 Device write policy is not one of the following deviceWritePolicyIsUnknown 2 Device write policy is unknown deviceWritePolicyIsWriteBack 3 Device write policy is write back deviceWritePolicyIsWriteThrough 4 Device write policy is write through deviceWritePolicyIsVariesByAddress 5 Device write policy varies by address deviceWritePolicyIsDeterminedByI0 6 Device write policy is determined by I O query Device Group 301 Table 13 10 Cache Device Status State Variable Name De 1 1 CacheDeviceStatusState Data Type Integer Possible Data Values Meaning of Data Value other 1 unknown 2 enabled 3 userDisabled 4 biosDisabled 5 Device state is not one of the following Device state is unknown Device is enabled Device is disabled by the user Device basic input output system BIOS is disabled Table 13 11 Cache Device ECC Type Variable Na
201. Name Object ID Description Syntax Access memoryDeviceFailureModes 1 3 6 1 4 1 674 10892 1 1100 50 1 20 Defines the failure modes of the memory device when the memoryDeviceStatus attribute is not OK It is a bit field that can be used to report more than one type of failure mode by using a combination of the defined bit masks DellMemoryDeviceFailureModes Read only Memory Device Manufacturer Name Name Object ID Description Syntax Access memoryDeviceManufacturerName 1 3 6 1 4 1 674 10892 1 1100 50 1 21 Defines the manufacturer of the memory device DellString Read only Memory Device Part Number Name Name Object ID Description Syntax Access memoryDevicePartNumberName 1 3 6 1 4 1 674 10892 1 1100 50 1 22 Defines the manufacturer s part number for the memory device DellString Read only Memory Device Serial Number Name Name Object ID Description Syntax Access memoryDeviceSerialNumberName 1 3 6 1 4 1 674 10892 1 1100 50 1 23 Defines the serial number of the memory device DellString Read only Device Group 271 Memory Device Asset Tag Name Name Object ID Description Syntax Access memoryDeviceAssetTagName 1 3 6 1 4 1 674 10892 1 1100 50 1 24 Defines the asset tag of the memory device DellString Read only Memory Device Speed Name Name Object ID Description Syntax Access memoryDeviceSpeedNam 1 3 6 1 4 1 674 10892 1 1100 50 1 25 This attrib
202. P traps to the target system or application When forwarding to an application the application should also be configured to receive the SNMP traps The IT Assistant application is already configured to receive the SNMP traps generated by Storage Management See your Windows operating system documentation for information on configuring the operating system to forward SNMP traps This information may be located under such topics as setting up SNMP or SNMP traps When configuring SNMP for Windows be sure that the SNMP traps are forwarded to the correct server For information on configuring an application to receive SNMP traps see the documentation for that application SNMP Trap Definitions The Storage Management management information base MIB defines the SNMP traps that Storage Management generates These traps correspond to the alerts documented in the Alert Descriptions and Corrective Actions section The MIB is located in sm mibs dcstorag mib a subdirectory of the Storage Management installation directory K NOTE Storage Management supports trap forwarding on both 32 bit and 64 bit operating systems Storage Management Alert Reference 675 SNMP Trap Variables The Storage Management SNMP traps use a set of variables that are included with every trap These variables are the following messagelDEvent e descriptionEvent locationEvent objectNameEvent objectOIDEvent objectNexusEvent e
203. Power Cord Table Syntax SEQUENCE OF ACPowerCordTableEntry Access Not accessible AC Power Cord Table Entry Name Object ID Description Syntax Access Index aCPowerCordTableEntry 1 3 6 1 4 1 674 10892 1 600 42 1 Defines the AC Power Cord Table entry ACPowerCord TableEntry Not accessible aCPowerCordchassisIndex aC PowerCordIndex AC Power Cord Chassis Index Name Object ID Description Syntax Access aCPowerCordChassisIndex 1 3 6 1 4 1 674 10892 1 600 42 1 1 Defines the index one based of the chassis containing this AC power cord DellObjectRange Read only Power Group 161 AC Power Cord Index Name aCPowerCordIndex Object ID 1 3 6 1 4 1 674 10892 1 600 42 1 2 Description Defines the index one based of this AC power cord Syntax DellObjectRange Access Read only AC Power Cord State Capabilities Name aCPowerCordStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 600 42 1 3 Description Defines the capabilities of this AC power cord Syntax DellACPowerCordStateCapabilities Access Read only AC Power Cord State Settings Name aCPowerCordStateSettings Object ID 1 3 6 1 4 1 674 10892 1 600 42 1 4 Description Defines the settings of this AC power cord Syntax DellACPowerCordStateSettings Access Read write AC Power Cord Status Name aCPowerCordStatus Object ID 1 3 6 1 4 1 674 10892 1 600 42 1 5 Description Defines the status of this AC power cord Syntax DellStatus Access Read onl
204. Processor sensor returned to a normal value Sensor Location lt Location in chassis gt Chassis Location lt Name of chassis gt Previous state was lt State gt Processor sensor status lt status gt Processor Device Status Warning 1603 Processor sensor Warning detected a warning value Sensor Location lt Location in chassis gt Chassis Location lt Name of chassis gt Previous state was lt State gt Processor sensor status lt status gt Information A processor sensor in the specified system transitioned back to a normal state The sensor location chassis location previous state and processor sensor status are provided A processor sensor in the specified system is in a throttled state The sensor location chassis location previous state and processor sensor status are provided Traps 657 Table 25 14 Processor Device Status Traps continued Trap ID Description Severity Cause Processor Device Status Failure 1604 Processor sensor Error detected a failure value Sensor Location lt Location in chassis gt Chassis Location lt Name of chassis gt Previous state was lt State gt Processor sensor status lt status gt A processor sensor in the specified system is disabled has a configuration error or experienced a thermal trip The sensor location chassis location previous state and processor sensor status are provided Pluggable Devic
205. Range Access Read only System Resource Input Output 1 0 Port Table Name systemResourcelOPortTable Object ID 1 3 6 1 4 1 674 10892 1 500 30 Description Defines the System Resource I O Port Table Syntax SEQUENCE OF SystemResourcelOPortTableEntry Access Not accessible System Resource 1 0 Port Table Entry Name systemResourcelOPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 Description Defines the System Resource I O Port Table entry Syntax SystemResourcelOPortTableEntry Access Not accessible Index systemResource OPortchassisIndex systemResource OPortIndex 124 System Resource Group System Resource 1 0 Port Chassis Index Name Object ID Description Syntax Access systemResourcelOPortchassisIndex 1 3 6 1 4 1 674 10892 1 500 30 1 1 Defines the index one based of this chassis DellObjectRange Read only System Resource 1 0 Port Index Name Object ID Description Syntax Access systemResourcelOPort Index 1 3 6 1 4 1 674 10892 1 500 30 1 2 Defines the index one based of the system resource I O ports in this chassis DellObjectRange Read only System Resource 1 0 Port State Capabilities Name Object ID Description Syntax Access systemResourcelOPortStateCapabilities 1 3 6 1 4 1 674 10892 1 500 30 1 3 Defines the capabilities of the system resource I O port DellStateCapabilities Read only System Resource 1 0 Port State Settings Name Object ID Description
206. Read only Processor Device Type Name Object ID Description Syntax Access 250 processorDeviceType 1 3 6 1 4 1 674 10892 1 1100 30 1 7 Defines the type of processor device DellProcessorDeviceType See Table 13 4 Read only Device Group Processor Device Manufacturer Name Name Object ID Description Syntax Access processorDeviceManufacturerName 1 3 6 1 4 1 674 10892 1 1100 30 1 8 Defines the name of manufacturer of the processor device DellString Read only Processor Device Status State Name Object ID Description Syntax Access processorDeviceStatusState 1 3 6 1 4 1 674 10892 1 1100 30 1 9 Defines the status state of the processor device DellProcessorDeviceStatusState See Table 13 2 Read only Processor Device Family Name Object ID Description Syntax Access processorDeviceFamily 1 3 6 1 4 1 674 10892 1 1100 30 1 10 Defines the family of the processor device DellProcessorDeviceFamily See Table 13 6 Read only Processor Device Maximum Speed Name Object ID Description Syntax Access processorDeviceMaximumSpeed 1 3 6 1 4 1 674 10892 1 1100 30 1 11 Defines the maximum speed of the processor device in megahertz MHz A zero 0 indicates that the speed is unknown DellUnsigned32BitRange Read only Device Group 251 Processor Device Current Speed Access Name Object ID Description Syntax processorDeviceCurrent Speed 1 3 6 1 4 1 674 10892 1
207. Read only COO State Name cooState Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 2 Description Defines the acquisition state of the system Syntax DellStateSettings Access Read only COO Acquisition Purchase Cost Name cooAquisitionPurchaseCost Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 3 Description Defines the purchase cost of the system Syntax DellUnsigned32BitRange Access Read write 394 Cost of Ownership Group COO Acquisition Waybill Number Name Object ID Description Syntax Access cooAquisitionWayBillNumber 1 3 6 1 4 1 674 10892 1 1600 10 1 4 Defines the waybill number of the system DellUnsigned32BitRange Read write COO Acquisition Install Date Name Name Object ID Description Syntax Access cooAquisitionInstallDateName 1 3 6 1 4 1 674 10892 1 1600 10 1 5 Defines the installation date and time for the system DellDateName Read write COO Acquisition Purchase Order Name Object ID Description Syntax Access cooAquisitionPurchaseOrder 1 3 6 1 4 1 674 10892 1 1600 10 1 6 Defines the purchase order number of the system DellUnsigned32BitRange Read write C00 Acquisition Purchase Date Name Name Object ID Description Syntax Access cooAquisitionPurchaseDateName 1 3 6 1 4 1 674 10892 1 1600 10 1 7 Defines the purchase date and time of the system DellDateName Read write Cost of Ownership Group 395 COO Acquisition Signing Authority Name Name cooAquisitionSigningAu
208. Resource DMA Transfer Width Variable Name De 1 1 ResourceDMATransferWidth Data Type Integer Possible Data Values Meaning of Data Value dmaTransferWidthIsOther 1 The DMA transfer width is not one of the following dmaTransferWidthIsunknown 2 The DMA transfer width is unknown dmaTransferWidthIs8Bits 3 The DMA transfer width is 8 bits dmaTransferWidthIs16Bits 4 The DMA transfer width is 16 bits dmaTransferWidthIs32Bits 5 The DMA transfer width is 32 bits dmaTransferWidthIs64Bits 6 The DMA transfer width is 64 bits dmaTransferWidthIs128Bits 7 The DMA transfer width is 128 bits System Resource Group 139 140 System Resource Group Power Group The Power Group provides information about power units a group of power supplies in a system chassis power supplies and voltage and amperage probes Power Group Tables The following management information base MIB tables define objects for the Power Group Power Unit Table Power Supply Table Voltage Probe Table Amperage Probe Table AC Power Switch Table AC Power Cord Table Battery Table Power Usage Table Power Unit Table Name powerUnitTable Object ID 1 3 6 1 4 1 674 10892 1 600 10 Description Defines the Power Unit Table Syntax PowerUnit TableEntry Access Not accessible Power Group 141 Power Unit Table Entry Name powerUnitTableEntry Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 Description Defines the Power
209. S Setup Control Group Basic Input Output System BIOS Setup Control Group variables provide information about the functions that the BIOS performs in your system This management information base MIB group includes variables for the boot sequence speakers diskettes ports network interface controllers NICs and the Wakeup on local area network LAN feature BIOS Group Tables The objects in this group define the BIOS control of devices and controller cards that are typically present in a system The following MIB tables define the BIOS Setup Control Group e BIOS Setup Control Table SCSI Control Table e Parallel Port Control Table e Serial Port Control Table e USB Control Table IDE Control Table e Diskette Control Table e Network Interface Control Table BIOS Setup Control Table Name biosSetUpControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 10 Description Defines the set of single devices in a chassis controlled by the BIOS Syntax BiosSetUpControlTableEntry Access Not accessible BIOS Setup Control Group 349 BIOS Setup Control Table Entry Name biosSetUpControlTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 Description Defines the BIOS Control Device Table entry Syntax BiosSetUpControl TableEntry Access Not accessible Index biosSetUpControlchassisIndex BIOS Setup Control Chassis Index Name biosSetUpControlchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 1 Description Defi
210. SerialInterfaceConnectionModeCapabilities 1 3 6 1 4 1 674 10892 1 1900 20 1 8 Defines the connection mode capabilities of the BMC serial interface DellBMCSerialConnectionModeCapabilities Read only BMC Serial Interface Connection Mode Settings Name Object ID Description Syntax Access bmcSerialInterfaceConnectionModeSettings 1 3 6 1 4 1 674 10892 1 1900 20 1 9 Defines the connection mode settings of the BMC serial interface DellBMCSerialConnectionModeSettings Read only BMC Serial Interface Flow Control Name Object ID Description Syntax Access bmcSerialInterfaceFlowControl 1 3 6 1 4 1 674 10892 1 1900 20 1 10 Defines the flow control type of the BMC serial interface DellBMCSerialFlowControl lype Read only Baseboard Management Controller Group 493 BMC Serial Interface Bit Rate Name bmcSerialInterfaceBitRate Object ID 1 3 6 1 4 1 674 10892 1 1900 20 1 11 Description Defines the bit rate of the BMC serial interface Syntax DellBMCSerialBitRateType Access Read only Baseboard Management Controller LAN Interface Table Name bmcLANInterfaceTable Object ID 1 3 6 1 4 1 674 10892 1 1900 30 Description Defines the Baseboard Management Controller BMC LAN Interface Table Syntax SEQUENCE OF BmcLANInterfaceTableEntry Access Not accessible BMC LAN Interface Table Entry Name bmcLANInterfaceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 Description Defines the Baseboard Management C
211. SettingsUnique Data Type Integer Possible Data Values Meaning of Data Value HI unknown 1 he remote flash BIOS s capabilities are unknown enabled 2 he remote flash BIOS update is disabled offline a inary 0 value or enabled online a binary 1 value om notReady 4 e he remote flash BIOS s state is not ready EA canceled 8 he remote flash BIOS has been canceled pending 16 he remote flash BIOS update is pending other 32 he remote flash BIOS state setting is not one of the previous values 206 Remote Flash BIOS Group Table 11 3 Remote Flash BIOS Completion Code Variable Name De1 1RemoteFlashBIOSCompletionCode Data Type Integer Possible Data Values Meaning of Data Value complet ionCodeIsOther 1 The completion code status is not one of the following complet ionCodeIsUnknown 2 The completion code is unknown not known or not monitored complet ionCodeIsOK 3 This completion code completed successfully complet ionCodeIsBadImage 4 This completion code is a bad flash BIOS image complet ionCodeIsNoFileAccess 5 Flash BIOS could not be accessed complet ionCodeIsNotReady 6 Flash BIOS memory not ready completionCodeIsDisabled 7 Flash BIOS is currently disabled p completionCodeIsNoBattery 8 A battery must be installed completionCodeIsNoChargedBattery 9 A fully charged battery must be installed complet
212. Size Name Object ID Description Syntax Access firmwareSize 1 3 6 1 4 1 674 10892 1 300 60 1 6 Defines the image size of the firmware in KB A zero 0 indicates that the size is unknown DellUnsigned16BitRange Read only Chassis Information Group 91 Firmware Type Name firmwareType Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 7 Description Defines the type of the firmware Syntax DellFirmware Type Access Read only Firmware Type Name Name firmwareTypeName Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 8 Description Defines the name of firmware type Syntax DellString Access Read only Firmware Update Capabilities Name firmwareUpdateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 9 Description Defines the bitmap of supported methods for firmware update Syntax DellUnsigned16BitRange Access Read only Firmware Date Name Name firmwareDateName Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 10 Description Defines the date of the firmware Syntax DellDateName Access Read only 92 Chassis Information Group Firmware Version Name Name firmwareVersionName Object ID 1 3 6 1 4 1 674 10892 1 300 60 1 11 Description Defines the version name of the firmware Syntax DellString Access Read only Intrusion Table The following objects and attributes describe the different forms of chassis intrusion a situation that occurs when the cover of a computer is removed Name Object ID Description Synta
213. Supply Sensor State Variable Name De11PowerSupplySensorState Data Type Integer Possible Data Values Meaning of Data Value presenceDetected 1 The power supply s presence is detected psFailureDetected 2 The power supply failure is detected predictiveFailure 4 The power supply sensor detects predictive failure psACLost 8 The power supply s AC power is lost acLostOroutOfRange 16 The power supply s AC power is lost or out of range 172 Power Group Table 8 4 Power Supply Sensor State continued Variable Name De11PowerSupplySensorState Data Type Integer Possible Data Values Meaning of Data Value acOutOfRangeBut Present 32 The power supply s AC power is present but it is out of range configurationError 64 The power supply sensor detects a configuration error Table 8 5 Power Supply Configuration Error Type Variable Name De1 1 PowerSupplyConfigurationErrorType Data Type Integer Possible Data Values Meaning of Data Value vendorMismatch 1 The power supply configuration error type is vendor mismatch revisionMismatch 2 The power supply configuration error type is revision mismatch processorMissing 3 The power supply configuration error type is processor missing Table 8 6 Voltage Probe Type Variable Name De1 1VoltageType Data Type Integer Possible Data Values Meaning of Data Value voltageProbeTypelIsOther 1 The vol
214. SupplyConnectionEntry Not accessible powerSupplyConnectionNumber Power Supply Connection Number Name Object ID Description Syntax Access powerSupplyConnectionNumber 1 3 6 1 4 1 674 10893 1 20 130 10 1 1 Identifies the instance number of the power supply connection entry Integer Read only Storage Management Group 579 Power Supply Connection Power Supply Name Name powerSupplyConnectionPowerSupplyName Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 1 2 Description Identifies the name of the power supply in this connection as represented in Storage Management Syntax DisplayString Access Read only Power Supply Connection Power Supply Number Name powerSupplyConnectionPowerSupplyNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 1 3 Description Identifies the instance number of the power supply in the powerSupplyTable in the connection Syntax Integer Access Read only Power Supply Connection Enclosure Name Name powerSupplyConnectionEnclosureName Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 1 4 Description Identifies the name of the enclosure as represented in Storage Management to which this power supply belongs Syntax DisplayString Access Read only Power Supply Connection Enclosure Number Name powerSupplyConnectionEnclosureNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 10 1 5 Description Identifies the instance number of the enclosure in the enclosureTable to which this power supply
215. Syntax Access systemResourcelOPortStateSettings 1 3 6 1 4 1 674 10892 1 500 30 1 4 Defines the state and allows the setting of the system resource T O port DellStateSettings Read write System Resource Group 125 System Resource 1 0 Port Status Name systemResourcelOPortStatus Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 5 Description Defines the status of the system resource I O port Syntax DellStateSettings Access Read only System Resource 1 0 Port Owner Index Reference Name systemResourcelOPortOwnerIndexReference Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 6 Description Defines the index to the associated system resource owner in this chassis Syntax DellObjectRange Access Read only System Resource I O Port Share Disposition Name systemResourcelOPortShareDisposition Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 7 Description Defines the share disposition of the system resource I O port Syntax DellResourceShareDisposition See Table 7 3 Access Read only System Resource 1 0 Port Starting Address Name systemResourcelOPortStartingAddress Object ID 1 3 6 1 4 1 674 10892 1 500 30 1 8 Description Defines the 64 bits of the starting address of the system resource I O port Syntax DellUnsigned64BitRange Access Read only 126 System Resource Group System Resource 1 0 Port Ending Address Name Object ID Description Syntax Access systemResourcelOPortEndingAddress 1 3 6 1 4 1 674 10892
216. Syntax DellObjectRange Access Read only Remote Dial Out Dial Out Index Name remoteDialOutDialOut Index Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 3 Description Defines the index one based of this remote access dial out functionality Syntax DellObjectRange Access Read only Remote Dial Out State Capabilities Name remoteDialOutStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 4 Description Defines the state capabilities of this remote access dial out functionality Syntax DellRemoteDialOutStateCapabilities See Table 19 27 Access Read only Remote Dial Out State Settings Name remoteDialOutStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 5 Description Defines the state settings of this remote access dial out functionality Syntax DellRemoteDialOutStateSettings See Table 19 28 Access Read write 464 Remote Access Group Remote Dial Out Status Name Object ID Description Syntax Access remoteDialOutStatus 1 3 6 1 4 1 674 10892 1 1700 60 1 6 Defines the status of this remote access dial out functionality DellStatus Read only Remote Dial Out IP Address Name Object ID Description Syntax Access remoteDialOutIPAddress 1 3 6 1 4 1 674 10892 1 1700 60 1 7 Defines the IP address for this remote access dial out destination IpAddress Read write Remote Dial Out Phone Number Name Name Object ID Description Syntax Access remoteDialOut PhoneNumberNam
217. Table 408 Cost of Ownership Table 393 Cost of Ownership tables 393 data types common 677 state capabilities 678 state settings 678 679 status 680 status probe 681 status redundancy 680 Device added to system 658 Device configuration error detected 659 Device Group 620 Cache Device Table 259 Generic Device Table 275 Keyboard Device Table 246 Memory Device Mapped Address Table 272 Memory Device Table 265 PCI Device Configuration Space Table 281 PCI Device Table 278 Pointing Device Table 243 Processor Device Table 248 variable values 292 Device removed from system 659 728 Index E Event Log viewing entries 673 G Global Data Group 510 Introduction Server Administrator Change Management MIB 23 Server Administrator Instrumentation MIB 18 Server Administrator Remote Access MIB 20 Server Administrator Storage Management MIB 22 Inventory 619 Inventory Group 619 L Local Response Agent Group LRA Action Table 388 LRA Global Settings 385 LRA Global Settings Table 386 variable values 390 Local Response Agent Group tables 385 Logical Devices Group 604 Memory device correction rate crossed a warning threshold 653 Memory device ECC Correctable error count crosseda warning threshold 653 Memory Group Physical Memory Tables 325 variable values 333 339 Memory Group Variable Values 343 MIB minor version number 38 MIB Maj
218. Table Entry Name chassisInformationTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 Description Defines the chassis information table entry Syntax ChassisInformation TableEntry Access Not accessible Index chassisIndexChassisInformation Chassis Index Chassis Information Name chassisIndexChassisInformation Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 1 Description Defines the index one based of this chassis The first chassis will be numbered one Syntax DellObjectRange Access Read only Chassis State Capabilities Name chassisStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 2 Description Defines the capabilities of the chassis Syntax DellStateCapabilities Access Read only Chassis State Settings Name chassisStateSettings Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 3 Description Defines the state settings for the chassis Syntax DellStateSettings Access Read write 66 Chassis Information Group Chassis Status Name Object ID Description Syntax Access chassisStatus 1 3 6 1 4 1 674 10892 1 300 10 1 4 Defines the status of the chassis DellStatus Read only Chassis Parent Index Reference Name Object ID Description Syntax Access Chassis Type Name Object ID Description Syntax Access Chassis Name Name Object ID Description Syntax Access chassisparent IndexReference 1 3 6 1 4 1 674 10892 1 300 10 1 4 Defines the index one based of the parent chassis of th
219. The size of the largest contiguous free space on this array disk in bytes that is less than a megabyte This size plus the arrayDiskLargestContiguousFreeSpaceInMB is the total size of the largest contiguous free space on the array disk Syntax Integer Access Read only Array Disk Target ID Name arrayDiskTargetID Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 15 Description Identifies the SCSI target ID which this array disk is assigned Syntax Integer Access Read only Array Disk LUN ID Name arrayDiskLunID Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 16 Description Identifies the array disk s logical unit number Syntax Integer Access Read only 554 Storage Management Group Array Disk Used Space in Megabytes Name arrayDiskUsedSpaceInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 17 Description Identifies the amount in megabytes of the used space on the array disk If this size is 0 it is smaller than a megabyte Syntax Integer Access Read only Array Disk Used Space in Bytes Name arrayDiskUsedSpaceInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 18 Description Identifies the size in bytes of the used space on the array disk that is smaller than a megabyte This size plus the arrayDiskUsedSpaceInMB is the total amount of used space on the array disk Syntax Integer Access Read only Array Disk Free Space in Megabytes Name arrayDiskFreeSpaceInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 19 Descrip
220. The system resource map is type one Table 7 2 Resource Owner Interface Type Variable Name De 1 LResourceOwnerInterfaceType Data Type Integer Possible Data Values Meaning of Data Value typeIsOther 1 The interface type is not one of the following typeIsUnknown 2 The interface type is unknown typeIsInternal 3 The interface type is internal typeIsISA 4 The interface type is an Industry Standard Architecture ISA bus 136 System Resource Group Table 7 2 Resource Owner Interface Type continued Variable Name De 1 1ResourceOwnerInterfaceType Data Type Integer Possible Data Values Meaning of Data Value typeIsEISA 5 The interface type is an Extended Industry Standard Architecture EISA bus typeIsMCA 6 The interface type is a microchannel architecture MCA bus typeIsTurboChannel 7 The interface type is a turbo channel bus Table 7 3 Resource Share Disposition Variable Name De1 1ResourceShareDisposition Data Type Integer Possible Data Values Meaning of Data Value shareIsOther 1 The share disposition is not one of the following shareIsUnknown 2 The share disposition is unknown not known or not monitored shareIsDeviceExclusive 3 The share disposition is device exclusive shareIsDriverExclusive 4 The share disposition is driver exclusive shareIsShared 5 The share disposition is shared Table 7 4 Resource Memory Flags
221. UID Value Name uUIDValue Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 4 Description Defines the value of the UUID for this chassis Syntax OCTET STRING SIZE 16 Access Read only POST Log Table This section defines attributes for the power on self test POST log When you turn on your computer the POST checks various system components before the operating system loads The POST tests the random access memory RAM the hard drives and the keyboard for example While the POST is running it makes a log file that system administrators can view The variables in this section also contribute to managing the POST log Name postLogTable Object ID 1 3 6 1 4 1 674 10892 1 300 30 Description Defines the POST Log Table Syntax SEQUENCE OF PostLogTableEntry Access Not accessible POST Log Table Entry Name postLogTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 Description Defines the POST Log Table entry Syntax PostLogTableEntry Access Not accessible Index postLogchassisIndex postLogRecordIndex Chassis Information Group 79 POST Log Chassis Index Name postLogchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only POST Log Record Index Name post LogRecordIndex Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 2 Description Defines the record number one based of the POST log Syntax DellUnsigned32BitRange Access Re
222. UUID for this chassis Syntax OCTET STRING SIZE 16 Access Read only Reference Guide Content Tables K NOTE Variable values are defined for any variable that is Server Administrator specific Industry standard variable definitions are documented in Standard Data Type Definitions Some of the tables in this guide have no technical significance in SNMP These tables are designed to show information in a readable form The following table for example defines the Server Administrator specific variable DellFanControlCapabilities The table provides the name of the variable its data type the values that are valid for the variable and the meaning of each value Introduction 29 Table 1 8 Example Variable Type Definition Table Variable Name De1 1 FanControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The fan s capabilities are unknown lowSpeedCapable 2 The fan can be set to low speed highSpeedCapable 4 The fan can be set to high speed lowOrHighSpeedCapable 6 The fan can be set to low or high speed This type of table is used throughout the reference guide to list and define variable values Tables that explain Server Administrator specific variable values are located in the final section of sections that define Server Administrator specific variables In the preceding example the variable name is DellFanControlCapabilities This variable must be express
223. V and shares a slot opening The adapter is on and the system slot is hot pluggable 320 Slot Group Table 14 3 System Slot Type Variable Name De11SystemSlotType Data Type Integer Possible Data Values Meaning of Data Value sys sys sys sys sys sys sys sys sys sys sys sys sys sys sys sys sys temSlo temSlo temSlo temSlo temSlo temSlo temSlo temSlo temSlo temSlo temSlo temSlo temSlo temSlo temSlo temSlo temSlo tIsOther 1 t IsUnknown 2 tIsISA 3 t ISMCA 4 tIsEISA 5 tIsPCI 6 t IsPCMCIA 7 t ISVLVESA 8 tIsProprietary 9 tIsProcessorCard 10 tIsProprietaryMemory 11 tIsIlORiserCard 12 t ISNuBUS 13 tIsPCI66MHz 14 tISAGP 15 tISAGP2X 16 tISAGP4X 17 The system slot type is not one of following The system slot type is unknown The system slot is Industry Standard Architecture ISA The system slot is Micro Channel Architecture MCA The system slot is Extended Industry Standard Architecture EISA The system slot is Peripheral Component Interconnect PCI The system slot is compliant with the Personal Computer Memory Card International Association PCMCIA standards The system slot is Very Low Voltage Enterprise System Architecture VLVESA The system slot is proprietary The system slot is a processor card The system slot is proprie
224. a Type Integer Possible Data Values Meaning of Data Value if set to zero 0 The object has no capabilities upperNonCriticalThresholdSet The upper noncritical threshold Capable 1 can be set lowerNonCriticalThresholdSet The lower noncritical threshold Capable 2 can be set upperNonCriticalThresholdDef The upper noncritical threshold aultCapable 4 can be set to default lowerNonCriticalThresholdDef The lower noncritical threshold aultCapable 8 can be set to default Standard Data Type Definitions 679 Dell Status Data Types Status data types include DellStatus DellStatusRedundancy and DellStatusProbe Table A 5 Dell Status Variable Name De11Status Data Type Integer Possible Data Values Meaning of Data Value other 1 he object s status is not one of the following unknown 2 ok 3 he object s status is unknown he object s status is OK nonCritical 4 he object s status is warning noncritical A critical 5 he object s status is critical failure nonRecoverable 6 he object s status is nonrecoverable dead Table A 6 Dell Status Redundancy Variable Name De11StatusRedundancy Data Type Integer Possible Data Values Meaning of Data Value other 1 The object s status is not one of the following unknown 2 The object s redundancy status is unknown full 3 The object is full
225. a particular managed computer chassis This information is collected during an inventory scan Inventory Group The following objects describe the fields for inventory information Inventory Locale Name inventoryLocale Object ID 1 3 6 1 4 1 674 10899 1 1 Description Defines the locale of the system Syntax DisplayString Access Read only Inventory Schema Version Name inventorySchemaVersion Object ID 1 3 6 1 4 1 674 10899 1 2 Description Defines the inventory schema implemented by this system Syntax DisplayString Access Read only Inventory System ID Name inventorySystemID Object ID 1 3 6 1 4 1 674 10899 1 3 Description Defines the System ID for the system Syntax SystemID Access Read only Change Management Group 619 620 Device Group The Device Group defines information about the devices discovered on the system during an inventory scan Identifying information includes the Component ID the Device ID and the Vendor ID Device Group Table The following object sets up the Device Group Table Name Object ID Description Syntax Access Device Entry Name Object ID Description Syntax Access Device Index Name Object ID Description Syntax Access deviceTable 1 3 6 1 4 1 674 10899 1 5 Defines the Device Table SEQUENCE OF DeviceEntry Not accessible deviceEntry 1 3 6 1 4 1 674 10899 1 5 1 Defines a device entry DeviceEntry Not accessible deviceIndex 1 3 6 1 4 1 674 10899
226. a system hang 1008 alertDrscBatt The RAC Minor Error RAC DRAC HI Low Battery detected its charge is battery below 25 charge is indicating below 25 that the full battery may only be able to power the DRSC for 8 10 minutes 1009 alertDrscTemp The RAC Information Status RAC DRAC III Normal Temperature temperature probe has probe reading returned returned to toa normal normal value 664 Traps Table 25 18 Enterprise specific Traps continued Trap Name Description Severity Category Cause Supported ID by RAC Platform 1010 alertDrscTemp The RAC Minor Status RAC DRAC III Warning Temperature temperature probe has probe reading detecteda exceeded Warning warning value threshold 1011 alertDrscTemp The RAC Critical Error RAC DRAC III Critical Temperature temperature probe has probe reading detected a exceeded failure critical or threshold critical value 1012 alertDrscVolt The RAC Information Error RAC voltage DRAC III Normal voltage probe reading has returns to returned normal to a normal value 1013 alertDrscVolt The RAC Minor Error RAC voltage DRAC III Warning voltage probe reading probe has exceeded detected a warning warning threshold value 1014 alertDrscVolt The RAC Critical Error RAC voltage DRAC III Critical voltage probe reading probe has exceeded detected a critical failure threshold or critical value Traps 665 Table 25 18 Enterprise specific Traps continued Trap Name Desc
227. able DellStatus Read only Agent Smart Thermal Shutdown Name Object ID Description Syntax Access agent SmartThermalShutdown 1 3 6 1 4 1 674 10893 1 20 110 15 Indicates the status of smart thermal shutdown for PowerVault 220S and PowerVault 221S enclosures Possible values 1 Enabled 2 Disabled 3 Not applicable Integer Read only Storage Management Group 515 Physical Devices Group The Physical Devices MIB group provides information about the devices managed by the Storage Management software and their relationships to each other The following MIB tables define objects and relationships connections among the objects 516 Controller Table describes available properties for each controller on the managed system Channel Table describes available properties for each channel on the managed system Enclosure Table describes available properties for each enclosure on the managed system Array Disk Table describes available properties for each physical array disk on the managed system Array Disk Enclosure Connection Table describes the connections between Fibre Channel array disks their enclosure and their associated controller For each object in the table its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found Array Disk Channel Connection Table describes the connections between S
228. ableEntry Not accessible processorDevicechassisIndex processorDeviceIndex Processor Device Chassis Index Name Object ID Description Syntax Access processorDevicechassisIndex 1 3 6 1 4 1 674 10892 1 1100 30 1 1 Defines the index one based of this chassis DellObjectRange Read only Processor Device Index Name Object ID Description Syntax Access processorDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 30 1 2 Defines the index of the processor device in this chassis DellObjectRange Read only Processor Device State Capabilities Name Object ID Description Syntax Access processorDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 30 1 3 Defines the capabilities of the processor device DellStateCapabilities Read only Device Group 249 Processor Device State Settings Name Object ID Description Syntax Access processorDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 30 1 4 Defines the state of the processor device DellStateSettings Read write Processor Device Status Name Object ID Description Syntax Access processorDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 30 1 5 Defines the status of the processor device DellStatus Read only Processor Port Index Reference Name Object ID Description Syntax Access processorPort IndexReference 1 3 6 1 4 1 674 10892 1 1100 30 1 6 Defines the index to the associated processor port in this chassis DellObjectRange
229. ache Device Level Name Object ID Description Syntax Access cacheDeviceLevel 1 3 6 1 4 1 674 10892 1 1100 40 1 11 Defines the level of the cache device DellCacheDeviceLevel See Table 13 8 Read only Cache Device Maximum Size Name Object ID Description Syntax Access 262 cacheDeviceMaximumSize 1 3 6 1 4 1 674 10892 1 1100 40 1 12 Defines the maximum size of the cache device in kilobytes KB A zero 0 indicates that the size is unknown DellUnsigned32BitRange Read only Device Group Cache Device Current Size Name cacheDeviceCurrentSize Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 13 Description Defines the current size of the cache device in KB A zero 0 indicates that the size is unknown Syntax DellUnsigned32BitRange Access Read only Cache Device Speed Name cacheDeviceSpeed Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 14 Description Defines the speed of the cache device in nanoseconds A zero 0 indicates that the speed is unknown Syntax DellUnsigned32BitRange Access Read only Cache Device Write Policy Name cacheDeviceWritePolicy Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 15 Description Defines the write policy of the cache device Syntax DellCacheDeviceWritePolicy See Table 13 9 Access Read only Cache Device Is Socketed Name cacheDevicelIsSocketed Object ID 1 3 6 1 4 1 674 10892 1 1100 40 1 16 Description Defines if the cache device is socketed Syntax DellBoolean
230. acturer Syntax DisplayString Access Read only Agent Version Name agentVersion Object ID 1 3 6 1 4 1 674 10893 1 20 100 4 Description This entry is obsolete Refer to softwareVersion Syntax DisplayString Access Read only Global Data Group The Global Data Management Information Base MIB Group defines the properties that identify status information about the system that the Storage Management software is managing and about the Storage Management SNMP agent Agent System Global Status Name agentSystemGlobalStatus Object ID 1 3 6 1 4 1 674 10893 1 20 110 1 Description This entry is obsolete Use the value agentGlobalSystemStatus Syntax Integer Access Read only 510 Storage Management Group Agent Last Global Status Name Object ID Description Syntax Access agentLastGlobalStatus 1 3 6 1 4 1 674 10893 1 20 110 2 This entry is obsolete Use the value agentLastGlobalSystemStatus Integer Read only Agent Time Stamp Name agentTimeStamp Object ID 1 3 6 1 4 1 674 10893 1 20 110 3 Description Identifies the last time that the agent values have been updated Universal time in sec since UTC 1 1 70 Syntax Integer Access Read only Agent Get Timeout Name agentGetTimeout Object ID 1 3 6 1 4 1 674 10893 1 20 110 4 Description Indicates the suggested timeout value in milliseconds for how long the SNMP getter should wait while attempting to poll the SNMP agent Syntax Integer Access Read only
231. ad only POST Log State Capabilities Unique Name postLogStateCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 3 Description Defines the capabilities of the object that is writing the POST log Syntax DellStateCapabilitiesLogUnique Access Read only POST Log State Settings Unique Name postLogStateSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 4 Description Defines the state of the object that is writing the POST log Syntax DellStateSettingsLogUnique Access Read write 80 Chassis Information Group POST Log Record Name Object ID Description postLogRecord 1 3 6 1 4 1 674 10892 1 300 30 1 5 Defines the data for the specified chassis and record index in the POST log being returned Syntax DisplayString SIZE 0 1024 Access Read only POST Log Format Name postLogFormat Object ID 1 3 6 1 4 1 674 10892 1 300 30 1 5 Description Defines format of the POST log Syntax DellLogFormat See Table 5 1 Access Read only Event Log Table Name eventLogTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 40 Description Defines the Event Log Table Syntax SEQUENCE OF EventLogTableEntry Access Not accessible Event Log Table Entry Name eventLogTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 40 1 Description Syntax Access Index Defines the event Log Table Entry EventLogTableEntry Not accessible eventLogchassisIndex eventLogRecordIndex Chassis Information Group
232. address See TCP IP IPMI Abbreviation for Intelligent Platform Management Interface which is an industry standard for management of peripherals used in enterprise computers based on Intel architecture The key characteristic of IPMI is that inventory monitoring logging and recovery control functions are available independent of the main processors BIOS and operating system IPX Acronym for internetwork packet exchange IRQ Abbreviation for interrupt request A signal that data is about to be sent to or received by a peripheral device travels by an IRQ line to the microprocessor Each peripheral connection must be assigned an IRQ number For example the first serial port in your computer COM1 is assigned to IROQ4 by default Two devices can share the same IRQ assignment but you cannot operate both devices simultaneously ISA Acronym for Industry Standard Architecture A 16 bit expansion bus design The expansion card connectors in an ISA computer are also compatible with 8 bit ISA expansion cards ITE Abbreviation for information technology equipment jumper Jumpers are small blocks on a circuit board with two or more pins emerging from them Plastic plugs containing a wire fit down over the pins The wire connects the pins and creates a circuit Jumpers provide a simple and reversible method of changing the circuitry in a printed circuit board Glossary 703 K Abbreviation for kilo indicating 1 000 KB Abbrevi
233. age system resources memory disk drives or printers for example UTP Abbreviation for unshielded twisted pair UUID Acronym for Universal Unique Identification V Abbreviation for volt s VAC Abbreviation for volt s alternating current varbind An algorithm used to assign and object identifier or OID The varbind gives rules for arriving at the decimal prefix that uniquely identifies an enterprise as well as the formula for specifying a unique identifier for the objects defined in that enterprise s MIB Glossary 721 variable A component of a managed object A temperature probe for example has a variable to describe its capabilities its health or status and certain indexes that you can use to help you in locating the right temperature probe vccl Abbreviation for Voluntary Control Council for Interference VCR Abbreviation for video cassette recorder VDC Abbreviation for volt s direct current VESA Acronym for Video Electronics Standards Association VGA Abbreviation for video graphics array VGA and SVGA are video standards for video adapters with greater resolution and color display capabilities than previous standards To display a program at a specific resolution you must install the appropriate video drivers and your monitor must support the resolution Similarly the number of colors that a program can display depends on the capabilities of the monitor the video driver and the amount of v
234. all of the variables that comprise the managed object UUID Introduction 27 The following table is an example of an SNMP table The table contains variables that must occur in a definite sequence In the example table the defined variables are UUID Chassis Index UUID Index UUID Type and UUID Value Example SNMP Table UUID Table These objects comprise the Server Administrator definitions for the UUID Name uUIDTable Object ID 1 3 6 1 4 1 674 10892 1 300 20 Description Defines the UUID table Syntax SEQUENCE OF UUIDTableEntry Access Not accessible UUID Table Entry Name uUIDTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 Description Defines the UUID table entry Syntax UUIDTableEntry Access Not accessible Index uUID Index uUIDchassisIndex UUID Chassis Index Name uUIDchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only 28 Introduction UUID Index Name uUIDIndex Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 2 Description Defines the index of the UUID in a specified chassis Syntax DellObjectRange Access Read only UUID Type Name uUIDType Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 3 Description Defines the type of the UUID for this chassis Syntax DellUUIDType Access Read only UUID Value Name uUIDValue Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 4 Description Defines the value of the
235. alues For information about changing SNMP community names see the Dell OpenManage Server Administrator User s Guide This guide is available on the Dell Support website at support dell com and on the Dell Systems Management Tools and Documentation DVD For additional guidelines see the Securing an SNMP Environment article dated May 2003 in the Dell Power Solutions magazine This magazine is also available at www dell com powersolutions K NOTE In Dell OpenManage Server Administrator version 5 3 SNMP Set operations are disabled by default Server Administrator provides support to enable or disable SNMP Set operations For more information on enabling or disabling SNMP Set operations in Server Administrator see the Dell OpenManage Server Administrator User s Guide or the Dell OpenManage Server Administrator Command Line Interface User s Guide Management Actions Management actions can be performed using the SNMP Set command These actions can consist of configuring a phone number for the system s owner rebooting a system or changing the asset tag of the system See the previous section SNMP Security for limitations on Set operations Introduction 35 SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations hard drive failures and so on Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned d
236. alues used in this section Table 16 1 Speaker Control Capabilities Unique Variable Name De1 1SpeakerControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 enableCapable 2 lowCapable 4 mediumCapable 8 highCapable 16 allVolumeCapable 30 Speaker control capabilities are unknown Setup BIOS can enable speaker control Setup BIOS can set the speaker volume to low Setup BIOS can set the speaker volume to medium Setup BIOS can set the speaker volume to high Setup BIOS can set the speaker volume to any of the three settings Table 16 2 Speaker Control Settings Unique Variable Name De11SpeakerControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 enabled 2 low 4 medium 8 high 16 Speaker control state is unknown Speaker control is enabled Speaker control volume is low Speaker control volume is medium Speaker control volume is high BIOS Setup Control Group 375 Table 16 3 Network Interface NIF Wakeup on LAN Capabilities Unique Variable Name De1 INI FwakeonLanControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 enableCapable 2 addInCardCapable 4 onBoardCapable 8 bothCapable 14 Setup BIOS Wakeup on LAN capabilities are unknown Setup BIOS is capable of enabling the NIF Wak
237. ame Name Object ID Description Syntax Access 286 networkDeviceServiceName 1 3 6 1 4 1 674 10892 1 1100 90 1 8 Defines the service name of the network device DellString Read only Device Group Network Device Driver Image Path Name Name networkDeviceDriverImagePathName Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 9 Description Defines the path to the binary image of the driver for the network device Syntax DellString Access Read only Network Device Driver Version Name Name networkDeviceDriverVersionName Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 10 Description Defines the version of the driver for the network device Syntax DellString Access Read only Network Device IP Address Name networkDevicelIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 11 Description Defines the IP address of the network device Syntax IpAddress Access Read only Network Device IP Subnet Mask Name networkDevicelPSubnetMask Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 12 Description Defines the IP subnet mask for the IP address currently assigned to the network device Syntax IpAddress Access Read only Device Group 287 Network Device Default Gateway IP Address Name Object ID Description Syntax Access networkDeviceDefaultGatewaylIPAddress 1 3 6 1 4 1 674 10892 1 1100 90 1 13 Defines the IP address of the default gateway for the network device IpAddress Read only Network Device DHCP Server
238. an error from which it cannot recover The sensor location chassis location previous state and chassis gt fan sensor value are Previous state was lt State gt provided Fan sensor value lt Reading gt Traps 641 Voltage Probe Traps Voltage probes monitor the number of volts across critical components Table 25 5 Voltage Probe Traps Trap ID Description Voltage Probe Normal 1152 642 Voltage sensor returned to a normal value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Voltage sensor value in Volts lt Reading gt If sensor type is discrete Discrete voltage state lt State gt Traps Severity Information Cause A voltage sensor in the specified system returned to a valid range after crossing a failure threshold The sensor location chassis location previous state and voltage sensor value are provided Table 25 5 Voltage Probe Traps continued Trap ID Description Severity Cause Voltage Probe Warning 1153 Voltage sensor detected a Warming warning value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Voltage sensor value in Volts lt Reading gt If sensor type is discrete Discrete voltage state lt State gt Vol
239. arallelPortControlModeSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Parallel port mode is unknown atModeEnabled 2 Setup BIOS has set the parallel port to AT mode ps2ModeEnabled 4 Setup BIOS has set the parallel port to Personal Systems 2 PS 2 mode ecpModeEnabled 8 Setup BIOS has set the parallel port to Extended Capabilities Port ECP mode eppModeEnabled 16 Setup BIOS has set the parallel port to Enhanced Parallel Port EPP mode Table 16 15 Serial Port Control Capabilities Variable Name De11SerialPortControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Setup BIOS serial port capabilities are unknown enableCapable 2 Setup BIOS can enable the serial port com1Capable 4 Setup BIOS can support serial port 1 enableAndCom1Capable 6 Setup BIOS can enable serial port 1 com2Capable 8 Setup BIOS can support serial port 2 enableAndCom2Capable 10 Setup BIOS is capable of enabling serial port 2 com3Capable 16 Setup BIOS can support serial port 3 enableAndCom3Capable 18 Setup BIOS is capable of enabling serial port 3 com4Capable 32 Setup BIOS can support serial port 4 enableAndCom4Capable 34 Setup BIOS is capable of enabling serial port 4 autoConfigCapable 64 Setup BIOS is capable of autoconfiguring all serial ports BIOS Setup Control Group 381 Table 16 15 Serial Port Contr
240. ardPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 20 1 8 Description Defines the name of the keyboard port Syntax DellString Access Read only 214 Port Group Keyboard Port BIOS Connector Type Name Object ID Description Syntax Access keyboardPortBIOSConnectorType 1 3 6 1 4 1 674 10892 1 1000 20 1 9 Defines the BIOS connector type of the keyboard port DellGenericPortConnectorlype Read only Processor Port Table Name Object ID Description Syntax Access processorPortTable 1 3 6 1 4 1 674 10892 1 1000 30 Defines the Processor Port Table IntegerProcessorPortTableEntry Not accessible Processor Port Table Entry Name Object ID Description Syntax Access Index processorPortTableEntry 1 3 6 1 4 1 674 10892 1 1000 30 1 Defines the Processor Port Table entry ProcessorPort TableEntry Not accessible processorPortchassisIndex processorPortIndex Processor Port Chassis Index Name Object ID Description Syntax Access processorPortchassisIndex 1 3 6 1 4 1 674 10892 1 1000 30 1 1 Defines the index one based of this chassis DellObjectRange Read only PortGroup 215 Processor Port Index Name processorPort Index Object ID 1 3 6 1 4 1 674 10892 1 1000 30 1 2 Description Defines the index of the processor ports in this chassis Syntax DellObjectRange Access Read only Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 100
241. are logged On some systems the log is not circular On these systems when the log becomes full subsequent hardware status messages are lost Hardware log sensor messages provide status and warning information about the noncircular logs that may fill up resulting in lost status messages Table 25 13 Hardware Log Traps Trap ID Description Severity Cause Hardware Log Normal 1552 Log size is no longer Information The hardware log on the near or at capacity specified system is no iba types lt Log typ s longer near or at its capacity usually as the result of clearing the log The log type information is provided Hardware Log Warning 1553 Log size is near or at Warning The size of a hardware log capacity on the specified system is hog itype srog types near or at the capacity of the hardware log The log type information is provided Hardware Log Full 1554 Log size is full Error The size of a hardware log iog hepa diog typ s on the specified system is at the capacity of the hardware log The log type information is provided 656 Traps Processor Device Status Traps The BMC on some systems reports the status of processor devices Processor device status traps provide status and warning information for processor devices present in a system with a BMC that reports the status of processor devices Table 25 14 Processor Device Status Traps Trap ID Description Cause Processor Device Status Normal 1602
242. as a binary octet string each byte of the octet string represents the state of the specific object The first byte returned represents the state of the first object and so on The bytes have the same definition type as DellStateSettings Syntax OCTET STRING SIZE 1 128 Access Read only System State Redundant Memory Unit Status Redundancy Name systemStateRedundantMemoryUnitStatusRedundancy Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 39 Description Defines the overall redundancy status for redundant memory Syntax DellStatusRedundancy Access Read only System State Redundant Memory Unit Status Details Name systemStateRedundantMemoryUnitStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 40 Description Defines the status of all redundant memory units in this chassis The results are returned as a binary octet string each byte of the octet string represents the status of the specific object The first byte returned represents the status of the first object and so on The bytes have the same definition type as DellStatusRedundancy Syntax OCTET STRING SIZE 1 128 Access Read only 58 System State Group System State Event Log Status Name systemStateEventLogStatus Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 41 Description Defines the overall status of this chassis ESM event log Syntax DellStatus Access Read only System State Power Unit Status Combined Name systemStatePowerUnitStatusCombined Object ID 1 3 6
243. as you use the software or hardware real mode An operating mode supported by 80286 or higher microprocessors real mode imitates the architecture of an 8086 microprocessor Glossary 713 refresh rate The rate at which the monitor redraws the video image on the monitor screen More precisely the refresh rate is the frequency measured in Hz at which the screen s horizontal lines are recharged sometimes also referred to as its vertical frequency The higher the refresh rate the less video flicker can be seen by the human eye The higher refresh rates are also noninterlaced RFI Abbreviation for radio frequency interference RGB Abbreviation for red green blue Acronym for Rambus In line Memory Module which is the Rambus equivalent of a DIMM module ROM Acronym for read only memory Your computer contains some programs essential to its operation in ROM code Unlike RAM a ROM chip retains its contents even after you turn off your computer Examples of code in ROM include the program that initiates your computer s boot routine and the POST rpm Abbreviation for revolutions per minute RTC Abbreviation for real time clock Battery powered clock circuitry inside the computer that keeps the date and time after you turn off the computer SAS Acronym for Serial Attached SCSI SCA Acronym for single connector attachment schema A collection of class definitions that describes managed objects in a particular
244. astic rectangular surface mount chip package that uses gull wing pins extending outward 716 Glossary SOJ Acronym for small outline package J lead a small dimension plastic rectangular surface mount chip package with j shaped pins on its two long sides SRAM Abbreviation for static random access memory Because SRAM chips do not require continual refreshing they are substantially faster than DRAM chips state Refers to the condition of an object that can have more than one condition For example an object may be in the not ready state status Refers to the health or functioning of an object For example a temperature probe can have the status normal if the probe is measuring acceptable temperatures When the probe begins reading temperatures that exceed limits set by the user it reports a critical status SVGA Abbreviation for super video graphics array VGA and SVGA are video standards for video adapters with greater resolution and color display capabilities than previous standards To display a program at a specific resolution you must install the appropriate video drivers and your monitor must support the resolution Similarly the number of colors that a program can display depends on the capabilities of the monitor the video driver and the amount of video memory installed in the computer switch On a computer system board switches control various circuits or functions in your computer system These sw
245. ata This method has its drawbacks If it is done frequently significant amounts of network bandwidth can be consumed If it is done infrequently the response to the fault condition may not occur in a timely fashion SNMP traps avoid these limitations of the polling method An SNMP trap is an asynchronous event indicating that something significant has occurred This is analogous to a pager receiving an important message except that the SNMP trap frequently contains all the information needed to diagnose a fault Two drawbacks to SNMP traps are that they are sent using UDP which is not a guaranteed delivery mechanism and that they are not acknowledged by the receiver An SNMP trap message contains the trap s enterprise OID the agent IP address a generic trap ID the specific trap ID a time stamp and zero or more variable bindings varbinds The combination of an enterprise OID and a specific trap ID uniquely identifies each Server Administrator defined trap A varbind consists of an OID and its value and provides additional information about the trap In order for a management system to receive SNMP traps from a managed system the node must be configured to send traps to the management system Trap destination configuration is dependent on the operating system When this configuration is done a management application on the management system can wait for traps and act on them when received For a list of traps supported by the se
246. ation Error Cleared Informational 487175 CPU Presence Processor Presence Informational detected 487303 CPU Not Present Processor Not Present Critical 487170 CPU BIST Built In Self Test Failure Critical Traps Table 25 19 BMC Traps continued TrapID Description Severity 487298 CPU BIST Built In Self Test Failure Informational Cleared 487176 CPU Disabled Processor Disabled Critical 487304 CPU Enabled Processor Enabled Informational 487178 CPU Throttle Processor Speed Reduced Warning 487306 CPU Throttle Cleared Normal Processor Informational Speed 527106 Power Supply Redundancy Degraded Warning 527105 Power Supply Redundancy Lost Critical 527104 Power Supply Redundancy Has Returned to Informational Normal 552704 Power Supply Inserted Informational 552832 Power Supply Removed Warning 552705 Power Supply Failure Critical 552833 Power Supply Failure Cleared Informational 552706 Power Supply Warning Warning 552834 Power Supply Warning Cleared Informational 552707 Power Supply AC Lost Critical 552835 Power Supply AC Restored Informational 789249 Memory Redundancy Has Been Lost Critical 789248 Memory redundancy Has Returned to Informational Normal 1076994 System Event Log SEL Cleared Informational 1076996 System Event Log SEL Full Logging Critical Disabled 2322176 ASR Automatic System Recovery Timer Critical Expired 2322177 ASR Automatic System Recovery Reset Critical
247. ation for kilobyte s 1 024 bytes KB sec Abbreviation for kilobyte s per second Kbit s Abbreviation for kilobit s 1 024 bits Kbit s sec Abbreviation for kilobit s per second key combination A command requiring you to press multiple keys at the same time For example you can reboot your computer by pressing the lt Ctrl gt lt Alt gt lt Del gt key combination kg Abbreviation for kilogram s 1 000 grams kHz Abbreviation for kilohertz 1 000 hertz LAN Acronym for local area network A LAN system is usually confined to the same building or a few nearby buildings with all equipment linked by wiring dedicated specifically to the LAN lb Abbreviation for pound s LCC Acronym for leaded or leadless chip carrier LIF Acronym for low insertion force Some computers use LIF sockets and connectors to allow devices such as the microprocessor chip to be installed or removed with minimal stress to the device 704 Glossary LED Abbreviation for light emitting diode An electronic device that lights up when a current is passed through it local bus On a computer with local bus expansion capability certain peripheral devices such as the video adapter circuitry can be designed to run much faster than they would with a traditional expansion bus Some local bus designs allow peripherals to run at the same speed and with the same width data path as the computer s microprocessor LPTn The device names
248. ation is corrupted Field Replaceable Unit Group 505 506 Field Replaceable Unit Group Storage Management Group The Storage Management Group is composed of the following e Storage Management Group information about the software product and system status e Storage Management Information Group properties about the Simple Network Management Protocol SNMP agent e Global Data Group system status e Physical Devices Group physical devices managed by the software e Logical Devices Group logical devices managed by the software e Storage Management Event Group SNMP traps Storage Management Group The Storage Management Information Base MIB Group defines the properties that identify information about the Storage Management software product and the current status of the system it manages Software Version Name softwareVersion Object ID 1 3 6 1 4 1 674 10893 1 20 1 Description Identifies the version number of the storage management component of the systems management software Syntax DisplayString Access Read only Storage Management Group 507 Global Status Name globalStatus Object ID 1 3 6 1 4 1 674 10893 1 20 2 Description Identifies global health for the subsystem managed by the Storage Management software This global status is customized for HP OpenView Other applications should refer to the agentSystemGlobalStatus entry in the globalData object group Possible values 1 Critica
249. auses an alert to be sent to the management console Some settings when reached can trigger a system shutdown or other response to prevent damage to the system State refers to the condition of an object that has more than one condition For example an object may be in a not ready or in an enabled state Status refers to the health of an object or how the object is functioning For example the status of a temperature probe that is measuring acceptable temperatures would be reported as normal When the probe begins reading temperatures that exceed limits set by the user it reports a critical status Tables This reference guide contains two types of tables tables that are used to organize and define variable values and tables that define MIB objects Readers must understand the difference between these two types of tables SNMP Tables Most of the MIB objects defined in this reference guide are organized into SNMP tables SNMP tables organize data into two dimensional structural arrays In SNMP objects that have a relationship to other objects are called columnar objects Columnar objects are objects used to form lists and tables When a MIB group is divided into one or more discrete tables the word table has a technical meaning An example is the section of this reference guide entitled Universal Unique Identifier UUID The UUID object has a type and a value that uniquely identifies an object such as a chassis The table defines
250. aximumSize Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 9 Description Defines the size in KB of the physical memory array Syntax DellUnsigned32BitRange Access Read only Physical Memory Array Total Number Sockets Name physicalMemoryArrayTotalNumberSockets Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 10 Description Defines the total number of memory sockets available for the physical memory array Syntax DellUnsigned32BitRange Access Read only 328 Memory Group Physical Memory Array In Use Number Sockets Name Object ID Description Syntax Access physicalMemoryArrayInUseNumberSockets 1 3 6 1 4 1 674 10892 1 1300 10 1 11 Defines the total number of memory sockets in use by the physical memory array DellUnsigned32BitRange Read only Physical Memory Array ECC Error Nonrecoverable Threshold Name Object ID Description Syntax Access physicalMemoryArrayECCErrorNonRecoverbeThreshold 1 3 6 1 4 1 674 10892 1 1300 10 1 12 Defines the value of the physical memory array Error Checking and Correction ECC error nonrecoverable threshold DellSigned32BitRange Read only Physical Memory Array ECC Error Critical Threshold Name Object ID Description Syntax Access physicalMemoryArrayECCErrorCriticalThreshold 1 3 6 1 4 1 674 10892 1 1300 10 1 13 Defines the value of the physical memory array ECC error critical threshold DellSigned32BitRange Read only Physical Memory
251. ay Table entry for the physical memory array with the same chassis index that this physical memory card is associated with DellObjectRange Read only This section includes definitions for server administrator specific variable values used in this section Table 15 1 Physical Memory Array Location Variable Name De11PhysicalMemoryArrayLocation Data Type Integer Possible Data Val ues Meaning of Data Value memoryArrayLocationIsOther 1 memoryArrayU memoryArrayU memoryArrayU memoryArrayU memoryArrayU memoryArrayU seIsUnknown 2 seIsSystemMemory 3 seIsVideoMemory 4 seIsFLASHMemory 5 seIsNonVolatileRAMMemory 6 seIsCacheMemory 7 The memory array location is not one of the following The memory array use is unknown The memory array is system memory The memory array is video memory The memory array is FLASH memory The memory array is nonvolatile RAM The memory array is cache memory Memory Group _ 343 Table 15 1 Physical Memory Array Location continued Variable Name De11PhysicalMemoryArrayLocation Data Type Integer Possible Data Values Meaning of Data Value memoryArrayLocationIsPCMCIA 8 memoryArrayLocationIsProprietary 9 memoryArrayLocationIsNUBUS 10 memoryArrayLocationIsPC98C20 11 memoryArrayLocationIsPC98C24 12 memoryArray memoryArray LocationIsPC98E 13 LocationIsPC98LocalBus
252. bControlchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 1 Description Defines index one based of this chassis Syntax DellObjectRange Access Read only USB Control Index Name usbControlIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 2 Description Defines the index one based of the USB in this chassis Syntax DellObjectRange Access Read only USB Control Capabilities Name usbControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 3 Description Defines the capabilities of the USB Syntax DellStateCapabilities Access Read only USB Control Settings Name usbControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 4 Description Defines the control settings for the USB Syntax DellStateSettings Access Read only BIOS Setup Control Group 367 USB Control Status Name usbControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 5 Description Defines the status of the USB Syntax DellStatus Access Read only USB Control Name Name usbControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 6 Description Defines the setup BIOS name of the USB Syntax DellString Access Read only IDE Control Table These objects enable you to track the attributes of Integrated Device Electronics IDE controller cards in your system Name ideControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 60 Description Defines the IDE Control Table Syntax IdeContro TableEntry Access Not accessible IDE Control Table E
253. bject ID Description Syntax Access aCPowerSwitchSettings 1 3 6 1 4 1 674 10892 1 600 40 1 4 Defines the settings of this AC power switch DellACPowerSwitchSettings Read write Power Group 159 AC Power Switch Redundancy Status Name aCPowerSwitchRedundancyStatus Object ID 1 3 6 1 4 1 674 10892 1 600 40 1 5 Description Defines the redundancy status of this AC power switch Syntax DellStatusRedundancy Access Read only AC Power Cord Count for Redundancy Name aCPowerCordCount ForRedundancy Object ID 1 3 6 1 4 1 674 10892 1 600 40 1 6 Description Defines the total number of AC power cords required for this AC power switch to have redundancy Syntax DellObjectRange Access Read only AC Power Switch Name Name aCPowerSwitchName Object ID 1 3 6 1 4 1 674 10892 1 600 40 1 7 Description Defines the name of this AC power switch Syntax DellString Access Read only AC Power Switch Redundancy Mode Name aCPowerSwitchRedundancyMode Object ID 1 3 6 1 4 1 674 10892 1 600 40 1 8 Description Defines the redundancy mode of this AC power switch Syntax DellACPowerSwitchRedundancyMode Access Read write 160 Power Group AC Power Switch Status Name aCPowerSwitchStatus Object ID 1 3 6 1 4 1 674 10892 1 600 40 1 9 Description Defines the status of this AC power switch Syntax DellStatus Access Read only AC Power Cord Table Name aCPowerCordTable Object ID 1 3 6 1 4 1 674 10892 1 600 42 Description Defines the AC
254. bles activation of chassis determined action s when a warning condition is detected The LRA can carry out chassis determined action s when a failure condition is detected Local Response Agent Group 391 Table 17 2 LRA Thermal Shutdown Capabilities Unique continued Variable Name De 1 1 LRAThermalShutdownCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value enableOnFailureCapable 10 The LRA enables activation of chassis determined action s when a failure condition is detected enableOnWarningOrFailure The LRA enables activation of chassis Capable 14 determined action s when either a failure or a warning condition is detected Table 17 3 Local Response Agent Settings Unique Variable Name De 1 LLocalResponseAgentSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value speakerControl 1 LRA is set to issue a speaker beep consoleAlert 2 LRA is set to issue a console alert broadcastMessage 4 LRA is set to issue a broadcast message osShutDown 8 LRA is set to issue an operating system shutdown reboot 16 LRA is set to issue a system reboot powerCycle 32 LRA is set to issue a system power cycle powerOFF 64 LRA is set to issue a system power off executeApplication 256 LRA is set to start a user mode application allLRASettingsUnique 383 LRA is set to all LRA settings combinations 392 Local Response Agent Group Co
255. boot by any of the preceding methods first Table 16 6 Boot Sequence Control Settings Unique Variable Name De1 1Boot SequenceControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value boot SequenceUnknown 1 Boot sequence state is unknown bootFromDisketteFirst 2 Setup BIOS is set to boot by diskette first boot FromHardDriveFirst 4 Setup BIOS is set to boot by IDE hard drive first boot FromDeviceList 8 Setup BIOS is set to boot by a device list boot FromCDROMFirst 16 Setup BIOS is set to boot by CD first BIOS Setup Control Group Table 16 7 BIOS Password Control Capabilities Variable Name De1 1BTOSPasswordControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value passwordControlCapabilitiesUn BIOS password capabilities are known 1 unknown passwordControlEnableCapable Setup BIOS is capable of enabling 2 password changes passwordControlJumperDisable Setup BIOS is capable of Capable 4 determining if password control can be jumper disabled passwordControlEnableANDJumper Setup BIOS is capable of enabling DisableCapable 6 password changes and of determining if password control can be jumper disabled Table 16 8 BIOS Password Control Settings Unique Variable Name De1 1BTOSPasswordControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown 1
256. boot your computer before running any commands in the autoexec bat file This start up file contains commands that specify which devices to install and which drivers to use This file also contains commands that determine how the operating system uses memory and controls files controller Achip that controls the transfer of data between the microprocessor and memory or between the microprocessor and a peripheral device such as a disk drive or the keyboard control panel The part of the computer that contains indicators and controls such as the power switch hard drive access indicator and power indicator conventional memory The first 640 KB of RAM Conventional memory is found in all computers coo Acronym for cost of ownership cooling unit Sets of fans or other cooling devices in a system chassis coprocessor A chip that relieves the computer s microprocessor of specific processing tasks A math coprocessor for example handles numeric processing A graphics coprocessor handles video rendering The Intel Pentium microprocessor for example includes a built in math coprocessor cpi Abbreviation for characters per inch CPU Abbreviation for central processing unit See also microprocessor CRC Abbreviation for cyclic redundancy code which is a number derived from and stored or transmitted with a block of data in order to detect corruption By recalculating the CRC and comparing it to the value originally transmi
257. bytes If this size is 0 it is smaller than a megabyte Integer Read only Virtual Disk Length in Bytes Name Object ID Description Syntax Access virtualDiskLengthBytes 1 3 6 1 4 1 674 10893 1 20 140 1 1 7 Identifies the portion of the virtual disk in bytes that is smaller than a megabyte This size plus the virtualDiskLengthInMB is the total size of the virtual disk Integer Read only Storage Management Group 607 Virtual Disk Free Space in Megabytes Name virtualDiskFreeSpaceInMB Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 8 Description This entry is obsolete This property is not supported by virtual disks managed under Storage Management Syntax Integer Access Read only Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 9 Description This entry is obsolete This property is not supported by virtual disks managed under Storage Management Syntax Integer Access Read only Virtual Disk Write Policy Name virtualDiskWritePolicy Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 10 Description Indicates whether the controller s write cache will be used when writing to a virtual disk Possible values 1 Enabled Adaptec Write Cache Enabled Protected 2 Disabled Adaptec Write Cache Disabled 3 LSI Write Back 4 LSI Write Through 5 Enabled Always Adaptec only 6 Enabled Always SAS only Syntax Integer Access Read only 608
258. ce Group Variable Values 292 14 Slot GhOU Pont ones eee EG 313 System Slot Group Table 313 System SlotTable 4 313 System Slot Variable Values 317 15 Memory Group 325 Physical Memory Tables 325 Physical Memory Array Table 325 Physical Memory Array Mapped Table 330 Physical Memory Configuration Table 333 Physical Memory Logging Table 335 Redundant Memory UnitTable 337 Physical Memory CardTable 340 Memory Group Variable Values 343 Contents 16 BIOS Setup Control Group 349 BIOS Group Tables 0 349 BIOS Setup Control Table 349 SCSI ControlTable 360 Parallel Port Control Table nnna aana 362 Serial Port ControlTable 364 USB Control Table 366 IDEControlTable 368 Diskette Control Table 370 Network Interface Control Table 372 BIOS Group Variable Values 375 17 Local Response Agent Group 385 LRAGroupTables 385 LRA Global Settings 385 LRA Global Settings Table 386 LRAActionTable 388 Local Response Agent Variable Values 390 18 Cost of Ownership Group 393 Cost of Ownership Group Tables 393 Cost of Ownership Tab
259. ce port Syntax DellStateSettings Access Read write Memory Device Port Status Name memoryDevicePortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 5 Description Defines the status of the memory device port Syntax DellStatus Access Read only Memory Device Port Security State Name memoryDevicePortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 6 Description Defines the security settings of the memory device port Syntax DellPortSecurityState Access Read only PortGroup 219 Memory Device Port Connector Type Name memoryDevicePortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 7 Description Defines the connector type of the memory device port Syntax DellMemoryDevicePortConnector Type See Table 12 4 Access Read only Memory Device Port Name Name memoryDevicePortName Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 8 Description Defines the name of the memory device port Syntax DellString Access Read only Memory Device Port BIOS Connector Type Name memoryDevicePortBIOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 9 Description Defines the BIOS connector type of the memory device port Syntax DellGenericPortConnectorlype Access Read only Memory Device Port Physical Memory Array Index Reference Name memoryDevicePort PhysicalMemoryArrayIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 10 Description Defines the index to the associated physical memory array Synta
260. ceSubTypeIsDiscrete 16 The cooling device subtype is a cooling device with discrete reading Table 9 3 Cooling Device Discrete Reading Variable Name De1 1CoolingDeviceDiscreteReading Data Type Integer Possible Data Values Meaning of Data Value coolingDevicelIsGood 1 The cooling device discrete reading is good coolingDevicelIsBad 2 The cooling device discrete reading is bad 196 Thermal Group Table 9 4 Temperature Probe Type Variable Name De11TemperatureProbeType Data Type Integer Possible Data Values Meaning of Data Value temperatureProbeTypelIsOther 1 The temperature probe subtype is not one of the following temperatureProbeTypelIsUnknown 2 The temperature probe subtype is unknown not known or not monitored temperatureProbeTypelIsAmbientESM 3 The temperature probe is for ambient Embedded Systems Management ESM temperatureProbeTypelIsDiscrete 16 The temperature probe subtype is a temperature probe with discrete reading Table 9 5 Temperature Probe Discrete Reading Variable Name De 1 1TemperatureDiscreteReading Data Type Integer Possible Data Values Meaning of Data Value temperaturelIsGood 1 The temperature probe discrete reading is good temperatureIsBad 2 The temperature probe discrete reading is bad Thermal Group 197 198 Thermal Group User Security Group The User Security Table defines the objects that allow administrato
261. cess he remote access he remote access NMP agent he remote access NMP traps nard nard nard nard ware has no out of band ware out of band SNMP nown ware has an out of band ware can send out of band Remote Access Group 471 Table 19 11 SNMP Settings Remote Access Out Of Band Simple Network Management Protocol Data Type Integer Possible Data Values Variable Name De 1 LRemoteAccessOutOfBandSNMPSettings Meaning of Data Value none 0 unknown 1 oobSNMPAgent Enabled 2 oobSNMPTrapsEnabled 4 he remote access hardware has no out of band SNMP settings he remote access hardware out of band SNMP settings are unknown The remote access hardware out of band SNMP agent is enabled The remote access hardware will send out of band SNMP traps Table 19 12 Remote User Admin State Capabilities Data Type Integer Variable Name De1 1RemoteUserAdminStateCapabilities Possible Data Values Meaning of Data Value none 0 unknownCapabilities 1 enableCapable 2 notReadyCapable 4 numericPagerCapable 8 alphaPagerCapable 16 emailCapable 32 privilegeCapable 64 he admin user has no state capabilities The admin user state capabilities are unknown he admin user can be disabled or enabled 4 he admin user can be in the not ready state The admin user support
262. cess hardware Syntax DellStateCapabilities Access Read only 428 Remote Access Group Remote Access State Settings Name remoteAccessStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 5 Description Defines the state setting of the remote access hardware Syntax DellStateSettings Access Read write Remote Access Status Name remoteAccessStatus Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 6 Description Defines the status of the remote access hardware Syntax DellStatus Access Read only Remote Access Product Info Name Name remoteAccessProduct InfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 7 Description Defines the name of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 63 Access Read only Remote Access Description Info Name Name remoteAccessDescriptionInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 8 Description Defines the description of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 255 Access Read only Remote Access Group 429 Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 9 Description Defines the version of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 63 Access Read only Remote Access Local Area Network LAN Capabilities Name remoteAccessLANCapabilities Object ID 1 3 6 1
263. cess hardware monitor settings are unknown The remote access hardware will monitor the external power supply if connected The remote access hardware will always monitor the external power supply Table 19 6 Remote Access Local Area Network LAN Capabilities Variable Name De 1 1RemoteAcc Data Type Integer essLANCapabilities Possible Data Values none 0 unknownCapabilities 1 nicCapable 2 nicDHCPCapable 4 Meaning of Data Value he remote access hardware has no LAN capabilities he remote access hardware LAN capabilities are unknown he remote access hardware has a network nterface controller NIC ee The remote access hardware NIC can use DHCP to obtain an IP address Remote Access Group _ 469 Table 19 7 Remote Access LAN Settings Variable Name De1 1RemoteAccessLANSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no LAN settings unknown 1 The remote access hardware LAN settings are unknown nicEnabled 2 The remote access hardware NIC is enabled nicDHCPEnabled 4 The remote access hardware NIC will use DHCP to obtain an IP address Table 19 8 Remote Access Host Capabilities Variable Name De 1 1RemoteAccessHostCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The remote access hardware has no host capabil
264. ch battery of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a battery The first byte returned represents the status of the first battery and so on The bytes have the same definition type as DellStatus OCTET STRING SIZE 1 128 Read only System State Group 63 64 System State Group Chassis Information Group The Chassis Information Group provides information about the type or types of chassis in your system as well as information about the light emitting diode LED indicators and settings for devices on each chassis Information is also available about the current date and time displayed on the chassis intrusion warnings watchdog timer systems management basic input output system SMBIOS and so on Chassis Information Group Tables The following management information base MIB tables define the objects in the Chassis Information Group Chassis Information Table UUID Table POST Log Table Event Log Table System BIOS Table Firmware Table Intrusion Table Baseboard Table Chassis Information Table The following object sets up the Chassis Information Table Name chassisInformationTable Object ID 1 3 6 1 4 1 674 10892 1 300 10 Description Defines the chassis information table Syntax SEQUENCE OF ChassisInformationTableEntry Access Not accessible Chassis Information Group 65 Chassis Information
265. chassisIndex genericDeviceIndex Generic Device Chassis Index Name Object ID Description Syntax Access genericDevicechassisIndex 1 3 6 1 4 1 674 10892 1 1100 70 1 1 Defines the index one based of this chassis DellObjectRange Read only Generic Device Index Name Object ID Description Syntax Access genericDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 70 1 2 Defines the index of the generic device in this chassis DellObjectRange Read only Generic Device State Capabilities Name Object ID Description Syntax Access 276 genericDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 70 1 3 Defines the capabilities of the generic device DellStateCapabilities Read only Device Group Generic Device State Settings Name Object ID Description Syntax Access genericDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 70 1 4 Defines the state of the generic device DellStateSettings Read write Generic Device Status Name Object ID Description Syntax Access genericDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 70 1 5 Defines the status of the generic device DellStatus Read only Generic Device System Slot Index Reference Name Object ID Description Syntax Access genericDeviceSystemSlotIndexReference 1 3 6 1 4 1 674 10892 1 1100 70 1 6 Defines the index of the system slot into which this generic device is plugged DellObjectRange Read only Generic Device Type Name
266. cimal value should be converted to hex and the appropriate bits should be parsed from hex Some of the more common bit combinations are defined in some variables but not all combinations are or will be defined Table A 2 Dell State Capabilities Variable Name De11StateCapabilities Data Type Integer Possible Data Values Meaning of Data Value if set to zero 0 The object has no capabilities unknownCapabilities 1 The object s capabilities are unknown enableCapable 2 The object can be disabled offline a binary 0 value or enabled online a binary value notReadyCapable 4 The object is not ready enableAndNotReadyCapable Enable and not ready capable 6 Table A 3 Dell State Settings Variable Name De11StateSettings Data Type Integer Possible Data Values Meaning of Data Value if set to zero 0 The object has no settings capabilities and its state is disabled unknown 1 The object s state is unknown 678 Standard Data Type Definitions Table A 3 Dell State Settings continued Variable Name De11StateSettings Data Type Integer Possible Data Values Meaning of Data Value enabled 2 The object s state is disabled offline a binary 0 value or enabled online a binary l value notReady 4 The object is not ready enableAndNotReady 6 The object is enabled and not ready Table A 4 Dell Probe Capabilities Variable Name De11ProbeCapabilities Dat
267. ckets and so on 20 Cluster Group defines variables for systems that 1800 operate as a cluster 21 Baseboard Management Controller Group provides 1900 information about the Baseboard Management Controller BMC that may be present in your system In addition to providing general information about the BMC this group provides information about the serial and local area network LAN interfaces of the BMC 25 Traps defines the types of alerts that can be sent to 5000 report the status of critical components Server Administrator Remote Access MIB The Server Administrator Remote Access MIB filename dces3rmt mib provides in band information about remote access hardware that may be present in your system The Server Administrator Remote Access MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information Table 1 3 describes each Server Administrator Remote Access MIB group and lists the MIB group number assigned to the MIB group The Server Administrator Remote Access MIB groups are identified by the SNMP OID 1 3 6 1 4 1 674 10892 1 lt MIB group number gt where lt MIB group number gt is the MIB group number assigned to the MIB group See the relevant section for more information about the MIB objects defined in a MIB group 20 Introduction Table 1 3 Server Administrator Remote Access MIB Sections in This Guide Section Topic MIB Group Numbers 19 Remote Acces
268. conflicts When troubleshooting tule out the possibility of such a conflict by rebooting your computer without starting any TSR programs TSOP Acronym for thin small outline package A very thin plastic rectangular surface mount chip package with gull wing pins on its two short sides TSOPs are about a third as thick as SOJ chips UART Acronym for universal asynchronous receiver transmitter the electronic circuit that makes up the serial port UDP Acronym for user datagram protocol UL Abbreviation for Underwriters Laboratories UMB Abbreviation for upper memory blocks 720 Glossary unicode A fixed width 16 bit world wide character encoding developed and maintained by the Unicode Consortium upper memory area The 384 KB of RAM located between 640 KB and 1 MB If the computer has an Intel386 or higher microprocessor a utility called a memory manager can create UMBs in the upper memory area in which you can load device drivers and memory resident programs UPS Abbreviation for uninterruptible power supply A battery powered unit that automatically supplies power to your computer in the event of an electrical failure USB Abbreviation for Universal Serial Bus A USB connector provides a single connection point for multiple USB compliant devices such as mice keyboards printers and computer speakers USB devices can also be connected and disconnected while the system is running utility A program used to man
269. consists of a series of digits separated by periods The OID functions in a similar fashion to a phone number The phone number 011 512 471 0000 uniquely identifies a single phone The phone number can be broken down into a number of components to uniquely identify a phone The first component 011 is the country code for the United States The second component 512 identifies the area code for central Texas The third component 471 is the phone exchange for a large state university in the city of Austin The final component 0000 is the main switchboard There are two main differences between the phone number example and an actual OID The first difference is that there are many more components in an OID up to 128 The combination of these components is called an OID prefix The second difference is that OIDs support the concept of indexes or keys The OID prefix specifies the data class but does not specify an instance of the data within the class Indexes can be used to identify the instances of a data class These indexes are referred to as the OID suffix Introduction 33 The assignment of values for each OID prefix component can be illustrated by using a tree structure The following is an example of an OID assignment ROOT CCITT 0 ISO 1 ORG 3 DOD 6 INTERNET 1 MGMT 2 MIB 1 EXPERIMENTAL 3 PRIVATE 4 ENTERPRISES 1 DELL 674 SNMPv2 6 In the preceding example the OID prefix for the Dell enterprise woul
270. controller Syntax DisplayString Access Read only Controller Minimum Driver Version Name controllerMinDriverVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 45 Description The minimum driver version for Storage Management to support the controller Syntax DisplayString Access Read write Controller SCSI Initiator ID Name controllerSCSIInitiatorID Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 46 Description The SCSI ID of the initiator Syntax Integer Access Read only Controller Channel Count Name controllerChannelCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 47 Description The number of channels on the controller Syntax Integer Access Read only Storage Management Group 531 Controller Reconstruct Rate Name controllerReconstructRate Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 48 Description The rate for reconstruct on the controller Syntax Integer Access Read write Controller Patrol Read Rate Name controllerPatrolReadRate Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 49 Description The rate for patrol read on the controller Syntax Integer Access Read only Controller BGI Rate Name controllerBGIRate Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 50 Description The rate for background initialization on the controller Syntax Integer Access Read only Controller Check Consistency Rate Name controllerCheckConsistencyRate Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 51 Description The rat
271. ct ID 1 3 6 1 4 1 674 10892 1 200 10 1 20 Description Defines the state of all cooling devices in this chassis The results are returned as a binary octet string Each byte of the octet string represents the state of a specific cooling device The first byte returned represents the state of the first cooling device the second byte returned represents the state of the second cooling device and so on The bytes have the same definition type as DellStateSettings Syntax OCTET STRING SIZE 1 128 Access Read only System State Cooling Device Status Combined Name systemStateCoolingDeviceStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 21 Description This attribute defines the cooling device status of all cooling devices in this chassis The results is returned as a combined status value The value has the same definition type as DellStatus Syntax DellStatus Access Read only System State Cooling Device Status Details Name systemStateCoolingDeviceStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 22 Description Defines the status of all cooling devices in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific cooling device The first byte returned represents the status of the first cooling device the second byte returned represents the status of the second cooling device and so on The bytes have the same definition type as DellStatus Syn
272. ction Table Syntax SEQUENCE OF LRAActionTableTableEntry Access Not accessible LRA Action Table Entry Name 1RAActionTableTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1500 20 1 Description Defines the LRA Action Table entry Syntax LRAActionTableTableEntry Access Not accessible Index IRAActionTablechassisIndex IRAActionTableActionNumberIndex LRA Action Table Chassis Index Name 1RAActionTablechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1500 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only 388 Local Response Agent Group LRA Action Table Action Number Index Name Object ID Description Syntax Access 1RAActionTableActionNumberIndex 1 3 6 1 4 1 674 10892 1 1500 20 1 2 Defines the LRA action number index The action number indexes are as follows 160 temperature failure action definition 168 cooling device failure action definition 172 voltage failure action definition 200 temperature warning action definition 202 voltage warning action definition 204 cooling device warning action definition 206 amperage failure action definition 208 amperage warning action definition 210 a power or cooling unit redundancy lost action definition 212 a power or cooling unit redundancy degraded action definition 214 power supply failed action definition 220 chassis intrusion action definition 228 memory device wa
273. ctorlype Read only PortGroup 217 Memory Device Port Table Name Object ID Description Syntax Access memoryDevicePortTable 1 3 6 1 4 1 674 10892 1 1000 40 Defines the Memory Device Port Table IntegerMemoryDevicePortTableEntry Not accessible Memory Device Port Table Entry Name Object ID Description Syntax Access Index memoryDevicePortTableEntry 1 3 6 1 4 1 674 10892 1 1000 40 1 Defines the Memory Device Port Table entry MemoryDevicePortTableEntry Not accessible memoryDevicePortchassisIndex memoryDevicePortIndex Memory Device Port Chassis Index Name Object ID Description Syntax Access memoryDevicePortchassisIndex 1 3 6 1 4 1 674 10892 1 1000 40 1 1 Defines the index one based of this chassis DellObjectRange Read only Memory Device Port Index Name Object ID Description Syntax Access 218 memoryDevicePort Index 1 3 6 1 4 1 674 10892 1 1000 40 1 2 Defines the index of the memory device port in this chassis DellObjectRange Read only Port Group Memory Device Port State Capabilities Name memoryDevicePortStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 3 Description Defines the capabilities of the memory device port Syntax DellStateCapabilities Access Read only Memory Device Port State Settings Name memoryDevicePortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 4 Description Defines the state and settings of the memory devi
274. d Warranty End Date Name Name Object ID Description Syntax Access cooExtendedWarrantyEndDateName 1 3 6 1 4 1 674 10892 1 1600 10 1 14 Defines the extended warranty end date for this system DellDateName Read write COO Extended Warranty Cost Name Object ID Description Syntax Access cooExtendedWarrantyCost 1 3 6 1 4 1 674 10892 1 1600 10 1 15 Defines the extended warranty cost date for this system DellUnsigned32BitRange Read write Cost of Ownership Group 397 COO Extended Warranty Provider Name Name cooExtendedWarrantyProviderName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 16 Description Defines the name of the extended warranty provider for this system Syntax DellCostofOwnershipString Access Read write COO Ownership Code Name cooOwnershipCode Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 17 Description Defines the ownership code for this system Syntax DellCooOwnershipCodes See Table 18 1 Access Read write COO Corporate Owner Name Name cooCorporateOwnerName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 18 Description Defines the name of the corporation that owns this system Syntax DellCostofOwnershipString Access Read write COO Hazardous Waste Code Name Name cooHazardousWast eCodeName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 19 Description Defines the hazardous waste code for this system Syntax DellCostofOwnershipString Access Read write 398 Cost of Ownership
275. d area may have 640 KB and the other mapped area may have between 1 Megabyte and 127 Megabytes PIC Acronym for programmable interrupt controller PIP Acronym for peripheral interchange program A CP M utility program that was used to copy files 710 Glossary pixel A single point on a video display Pixels are arranged in rows and columns to create an image A video resolution such as 640 x 480 is expressed as the number of pixels across by the number of pixels up and ER PLCC Acronym for plastic leaded chip carrier Plug and Play An industry standard specification that makes it easier to add hardware devices to personal computers Plug and Play provides automatic installation and configuration compatibility with existing hardware and dynamic support of mobile computing environments PME Abbreviation for Power Management Event A PME is a pin on a peripheral component interconnect that allows a PCI device to assert a wake event POST Acronym for power on self test Before the operating system loads when you turn on your computer the POST tests various system components such as RAM the disk drives and the keyboard power supply An electrical system that converts AC current from the wall outlet into the DC currents required by the computer circuitry The power supply in a personal computer typically generates multiple voltages power unit A set of power supplies in a system chassis ppm Abbreviation for pages
276. d be 1 3 6 1 4 1 674 The numbers in boldface type show the categories and numbers that apply to Server Administrator All Server Administrator defined OIDs consist of 1 3 6 1 4 1 674 followed by additional component values 34 Introduction SNMP Security SNMP version 1 has a very limited security mechanism SNMP agents support the use of a community string which is configured at each SNMP agent and is passed as a part of all SNMP request messages There is no verification that the requester is actually a member of the specified community Because most system and network management data is not confidential this limited security is acceptable for Get types of requests On the other hand this security is not acceptable for Set types of operations where an SNMP request could power off a system reconfigure a redundant array of independent disks RAID card and so on Some vendors have chosen not to support SNMP Set operations for this reason Server Administrator is able to support SNMP Set operations because its SNMP agents implement a hash digest mechanism to prevent unauthorized SNMP Set operations One limitation of this practice is that only server administrator developed SNMP management applications have the capability to support the hash digest mechanism K NOTE The default SNMP agent configuration usually includes a SNMP community name such as public For security reasons change the SNMP community names from their default v
277. d for this power unit to have redundancy DellString Read only powerUnitName 1 3 6 1 4 1 674 10892 1 600 10 1 7 Defines the name of the power unit in this chassis DellString Read only Power Group 143 Power Unit Status Name powerUnitStatus Object ID 1 3 6 1 4 1 674 10892 1 600 10 1 8 Description Defines the status of the power unit in this chassis Syntax DellStatus Access Read only Power Supply Table Name powerSupplyTable Object ID 1 3 6 1 4 1 674 10892 1 600 12 Description Defines the Power Supply Table Syntax PowerSupply TableEntry Access Not accessible Power Supply Table Entry Name powerSupplyTableEntry Object ID 1 3 6 1 4 1 674 10892 1 600 12 1 Description Defines the Power Supply Table entry Syntax PowerSupply TableEntry Access Not accessible Index powerSupplychassisIndex powerSupplyIndex Power Supply Chassis Index Name powerSupplychassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 12 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only 144 Power Group Power Supply Index Name Object ID Description Syntax Access powerSupplyIndex 1 3 6 1 4 1 674 10892 1 600 12 1 2 Defines the index of power supply DellObjectRange Read only Power Supply State Capabilities Unique Name Object ID Description Syntax Access powerSupplyStateCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 600 12 1 3 Defines the capabilities of the powe
278. d physical memory array in this chassis DellObjectRange Read only Physical Memory Array Mapped Starting Address Name Object ID Description Syntax Access physicalMemoryArrayMappedStartingAddress 1 3 6 1 4 1 674 10892 1 1300 20 1 7 Defines the physical starting address in KB of the memory array mapped address DellUnsigned64BitRange Read only Physical Memory Array Mapped Ending Address Name Object ID Description Syntax Access 332 physicalMemoryArrayMappedEndingAddress 1 3 6 1 4 1 674 10892 1 1300 20 1 8 Defines the physical ending address in KB of the memory array mapped address DellUnsigned64BitRange Read only Memory Group Physical Memory Array Mapped Partition Width Name Object ID Description Syntax Access physicalMemoryArrayMappedPartitionWidth 1 3 6 1 4 1 674 10892 1 1300 20 1 9 Defines the number of memory devices that form a single row in the memory array mapped address A zero 0 indicates that the number is unknown DellUnsigned32BitRange Read only Physical Memory Configuration Table This table defines how the physical memory of a system chassis is set up for example which redundant memory types are supported and whether redundant memory is active The following object sets up the Physical Memory Configuration Table Name Object ID Description Syntax Access physicalMemoryConfigTable 1 3 6 1 4 1 674 10892 1 1300 30 Defines the Physical Memo
279. device Syntax DellUnsigned8BitRange Access Read only Network Device IRQ Name networkDeviceIRQ Object ID 1 3 6 1 4 1 674 10892 1 1100 90 1 20 Description Defines the interrupt request number of the network device Syntax DellUnsigned16BitRange Access Read only Device Group 289 Network Device Base 10 Port Address Name Object ID Description Syntax Access networkDeviceBaselIOPortAddress 1 3 6 1 4 1 674 10892 1 1100 90 1 21 Defines the base input outport port address of the network device DellUnsigned32BitRange Read only Network Device Teaming Flags Name Object ID Description Syntax Access networkDeviceTeamingFlags 1 3 6 1 4 1 674 10892 1 1100 90 1 22 Defines the teaming features of the network device DellNetworkDeviceTeamingFlags see Table 13 21 Read only Network Device TOE Capability Flags Name Object ID Description Syntax Access networkDeviceTOECapabilityFlags 1 3 6 1 4 1 674 10892 1 1100 90 1 23 Defines the TCP IP Offload Engine TOE capability flags of the network device DellNetworkDevice TOECapabilityFlags see Table 13 22 Read only Network Device TOE Enabled Name Object ID Description Syntax Access 290 networkDeviceTOEEnabled 1 3 6 1 4 1 674 10892 1 1100 90 1 24 Defines if TOE is enabled for the network device DellBoolean Read only Device Group Network Device RDMA Capability Flags Name Object ID Description Syntax Access network
280. ding is good amperagelIsBad 2 The amperage probe discrete reading is bad Table 8 10 AC Power Switch Capabilities Variable Name De1 LACPowerSwitchCapabilities Data Type Integer Possible Data Values Meaning of Data Value unknownCapabilities 1 The AC power switch s capabilities are unknown inputSourceCord1iNoReturnCapable 2 Input source is AC power cord 1 with no return inputSourceCord1ReturnCapable 4 Input source is AC power cord 1 with return inputSourceCord2NoReturnCapable 8 Input source is AC power cord 2 with no return input SourceCord2ReturnCapable 16 Input source is AC power cord 2 with return input SourceSharedCapable 32 Input source is shared Table 8 11 AC Power Switch Settings Variable Name De1 LACPowerSwitchSettings Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The AC power switch s settings are unknown inputSourceCord1NoReturn 2 Input source is AC power cord 1 with no return PowerGroup__ 177 Table 8 11 AC Power Switch Settings continued Variable Name De1 LACPowerSwitchSettings Data Type Integer Possible Data Values Meaning of Data Value input SourceCord1Return 4 Input source is AC power cord 1 with return input SourceCord2NoReturn 8 Input source is AC power cord 2 with no return inputSourceCord2Return 16 Input source is AC power cord 2 with return input SourceShared 32 Input source
281. e Chassis Watchdog Control Expiry Time Capabilities Unique Name chassiswatchDogControlExpiryTimeCapabilities Unique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 35 Description Defines the capabilities of the watchdog expiry timer object Syntax DellWatchDogTimerCapabilities See Table 5 13 Access Read only 74 Chassis Information Group Chassis Watchdog Control Expiry Time Name Object ID Description Syntax Access chassiswatchDogControlExpiryTime 1 3 6 1 4 1 674 10892 1 300 10 1 36 Defines the current reading and allows setting of the nonrecoverable watchdog expiry timer object DellUnsigned16BitRange Read write Chassis Allow Set Commands From SNMP Name Object ID Description Syntax Access chassisallowSETCommandsfromSNMP 1 3 6 1 4 1 674 10892 1 300 10 1 37 Specifies whether Simple Network Management Protocol SNMP Set type commands are allowed by Server Administrator This attribute does not reflect whether SNMP Set type commands are allowed by the SNMP master agent DellBoolean Read only Chassis Power Button Control Capabilities Unique Name Object ID Description Syntax Access chassisPowerButtonControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 300 10 1 38 Defines the capabilities of the power button control function DellPowerButtonControlCapabilities See Table 5 16 Read only Chassis Information Group 75 Chassis Power Button Control Settings Unique Name cha
282. e DellObjectRange Read only System Resource Interrupt State Capabilities Name Object ID Description Syntax Access systemResourcelInterruptStateCapabilities 1 3 6 1 4 1 674 10892 1 500 50 1 3 Defines the capabilities of this system resource interrupt DellStateCapabilities Read only System Resource Interrupt State Settings Name Object ID Description Syntax Access systemResourceInterruptStateSettings 1 3 6 1 4 1 674 10892 1 500 50 1 4 Defines the state of this system resource interrupt DellStateSettings Read write System Resource Interrupt Status Name Object ID Description Syntax Access systemResourceInterruptStatus 1 3 6 1 4 1 674 10892 1 500 50 1 5 Defines the status of this system resource interrupt DellStatus Read only System Resource Group 131 System Resource Interrupt Owner Index Reference Name systemResourceInterruptOwnerIndexReference Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 6 Description Defines the index for the associated system resource owner in this chassis Syntax DellObjectRange Access Read only System Resource Interrupt Owner Share Disposition Name systemResourcelInterruptShareDisposition Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 7 Description Defines the share disposition of the system resource interrupt Syntax DellResourceShareDisposition See Table 7 3 Access Read only System Resource Interrupt Level Name systemResourceInterrup
283. e 1 3 6 1 4 1 674 10892 1 1700 60 1 8 Defines the phone number for this remote access dial out destination DisplayString SIZE 0 95 Read write Remote Dial Out PPP Username Name Object ID Description Syntax Access remoteDialOutPPPUserName 1 3 6 1 4 1 674 10892 1 1700 60 1 9 Defines the PPP username for this remote access dial out destination DisplayString SIZE 0 31 Read write Remote AccessGroup__ 465 Remote Dial Out PPP Password Name Name remoteDialOut PPPPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 10 Description Defines the PPP password for this remote access dial out destination Syntax DisplayString SIZE 0 31 Access Read write Remote Access Variable Values This section includes definitions for server administrator specific variable values used in this section Table 19 1 Remote Access Type Variable Name De1 LRemoteAccessType Data Type Integer Possible Data Values Meaning of Data Value remoteAccessTypelsOther 1 The remote access type is not one of the following remoteAccessTypelsUnknown 2 The remote access type is unknown remoteAccessTypeIsDRACITII 3 The remote access type is DRAC III remoteAccessTypelIsERA 4 The remote access type is ERA Table 19 2 Remote Access Control Capabilities Variable Name De 1LRemoteAccessControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 Th
284. e 1 3 6 1 4 1 674 10892 1 1800 10 1 6 Defines the type of the cluster DellClusterType Read only Cluster Type Description Name Name Object ID Description Syntax Access Cluster Name Name Object ID Description Syntax Access clusterTypeDescriptionName 1 3 6 1 4 1 674 10892 1 1800 10 1 7 Defines the description name for the type of the cluster DellString Read only clusterName 1 3 6 1 4 1 674 10892 1 1800 10 1 8 Defines the name of the cluster DellString Read only ClusterGroup 485 486 Cluster Group Variable Values This section includes definitions for Server Administrator specific variable values used in this section Table 20 1 Cluster Type Variable Name De11ClusterType Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The cluster type is unknown highAvailabilityCluster 2 The cluster type is a high availability cluster l Cluster Group Baseboard Management Controller Group The Baseboard Management Controller BMC monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds The BMC Group provides information about the BMC that may be present in your system In addition to providing general information about the BMC this group provides information about the serial and local area network LAN interfaces of the BMC Baseb
285. e SMSSupportedTypes Data Type Integer Possible Data Values Meaning of Data Value support sSNMP 1 This system supports SNMP SUppOrtsDMI 2 This system supports DMI supportsSNMPandDMI 3 This system supports SNMP and DMI support sCIMOM 4 This system supports CIM supportsSNMPandCIMOM 5 This system supports SNMP and CIM Systems Management Software Group 43 44 Table 3 2 Systems Management Software Feature Flags Variable Name SMSFeatureFlags Data Type Integer Possible Data Values Meaning of Data Value none 0 The Systems Management Software features are not enabled webOneToOneManagement Preferred 1 The web 1 1 management preferred feature is enabled Table 3 3 Systems Management Software SNMP Agent Feature Flags Variable Name SMSSNMPAgentFeatureFlags Data Type Integer Possible Data Values Meaning of Data Value none 0 The Systems Management Software SNMP agent features are not enabled support sSparseTables 1 The SNMP agent supports sparse tables Systems Management Software Group System State Group The Management Information Base MIB variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system Components monitored under the System State Group include power supplies AC power cords AC power switches and cooling devices as well as temperature fan amperage and
286. e SeeTable 16 6 Access Read only BIOS Setup Control Group 355 BIOS Setup Control Boot Sequence Control Status Name bSUCbootSequenceControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 24 Description Defines the status of the boot sequence Syntax DellStatus Access Read only BIOS Setup Control Boot Sequence Control Name Name bSUCboot SequenceControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 25 Description Defines the control name of the boot sequence Syntax DellString Access Read only BIOS Setup Control Administrator Password Control Capabilities Unique Name bsuCadministratorPasswordControlCapabilities Unique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 26 Description Defines the capabilities of the administrator password control Syntax DellBIOSPasswordControlCapabilities Unique Access Read only BIOS Setup Control Administrator Password Control Settings Unique Name bsuUCadministratorPasswordControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 27 Description Defines the settings for administrator password control Syntax DellBIOSPasswordControlSettingsUnique See Table 16 9 Access Read write 356 BIOS Setup Control Group BIOS Setup Control Administrator Password Control Status Name bSUCadministratorPasswordControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 28 Description Defines the status for administrator password control Syntax DellStatus Access Read only BIOS Set
287. e Traps Server Administrator monitors the addition and removal of pluggable devices such as memory cards Device traps provide information about the addition and removal of such devices Table 25 15 Pluggable Device Traps Trap ID Description Severity Cause Pluggable Device Addition 1651 Device added to system Information Device Location lt Location in chassis gt Chassis Location lt Name of chassis gt Additional Details lt Additional details for the events gt 658 Traps A device was added to the specified system The device location chassis location and additional event details if available are provided Table 25 15 Pluggable Device Traps Trap ID Description Severity Cause Pluggable Device Removal 1652 Device removed from system Information Device Location lt Location in chassis gt Chassis Location lt Name of chassis gt Additional Details lt Additional details for the events gt Pluggable Device Configuration Error 1653 Device configuration error Error detected Device Location lt Location in chassis gt Chassis Location lt Name of chassis gt Additional Details lt Additional details for the events gt A device was removed from the specified system The device location chassis location and additional event details if available are provided A configuration error was detected for a pluggable device in the specified system The d
288. e as DellStatus Syntax OCTET STRING SIZE 1 128 Access Read only 48 System State Group System State Voltage State Details Name systemStateVoltageStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 11 Description Defines the state of all voltage probes in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific voltage probe The first byte returned represents the status of the first voltage probe the second byte returned represents the status of the second voltage probe and so on The bytes have the same definition type as DellStateSettings Syntax OCTET STRING SIZE 1 128 Access Read only System State Voltage Status Combined Name systemStateVoltageStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 12 Description Defines the status of all voltage probes in this chassis Syntax DellStatus Access Read only System State Voltage Status Details Name systemStateVoltageStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 13 Description Defines the status of all voltage probes in this chassis Syntax OCTET STRING SIZE 1 128 Access Read only System State Group 49 System State Amperage State Details Name systemStateAmperageStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 14 Description Defines the state of all current probes in this chassis The results are returned as a binary octet string Each byte of t
289. e for check consistency on the controller Syntax Integer Access Read only 532 Storage Management Group Controller Patrol Read Mode Name Object ID Description Syntax Access controllerPatrolReadMode 1 3 6 1 4 1 674 10893 1 20 130 1 1 52 Identifies the patrol read mode Possible values 1 Automatic enabled 2 Manual enabled 3 Disabled Integer Read only Controller Patrol Read State Name Object ID Description Syntax Access controllerPatrolReadState 1 3 6 1 4 1 674 10893 1 20 130 1 1 53 The state of the patrol read Possible values 1 Stopped not running 2 Ready ready to start 4 Active is running 8 Aborted has aborted Integer Read only Controller Patrol Read Iterations Name Object ID Description Syntax Access controllerPatrolReadIterations 1 3 6 1 4 1 674 10893 1 20 130 1 1 54 The number of times Patrol Read has been run on this controller Integer Read only Storage Management Group 533 Channel Table This table describes available properties for each channel on the managed system The following object sets up the Channel Table Name channelTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 Description Defines the channel table Syntax SEQUENCE OF ChannelEntry Access Not accessible Channel Entry Name channelEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 2 1 Description Defines the channel table entry Syntax ChannelEntry Access Not
290. e is unspecified static 1 IP address is static dhcp 2 Dynamic Host Configuration Protocol DHCP used to obtain IP address biosOrSystemSoftware 3 BIOS or system software provided IP Address other 4 Other protocol used to obtain IP address Table 21 6 BMC Management Controller Type Variable Name Del 1ManagementControllerType Data Type Integer Possible Data Values Meaning of Data Value legacyBMC 0 Controller type is legacy Baseboard Management Controller iDRAC 8 Controller type is iDRAC 500 Baseboard Management Controller Group Field Replaceable Unit Group A field replaceable unit FRU is a part that can be removed and replaced without having to send the system to a repair facility The Field Replaceable Unit Group provides information about the field replaceable units that may be present in your system Field Replaceable Unit Group Tables The objects in the FRU group define information such as manufacturer serial number part number and revision for field replaceable units The following MIB tables define the FRU group Field Replaceable Unit Table Name fruTable Object ID 1 3 6 1 4 1 674 10892 1 2000 10 Description Defines the Field Replaceable Unit table Syntax SEQUENCE OF FruTableEntry Access Not accessible FRU Table Entry Name fruTableEntry Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 Description Defines the FRU Table Entry Syntax FruTableEntry Access Not access
291. e language of the systems management software Syntax DisplayString SIZE 0 255 Access Read only Systems Management Software Global Version Name Name systemManagement SoftwareGlobalVersionName Object ID 1 3 6 1 4 1 674 10892 1 100 10 Description Defines the global version of the systems management software Syntax DellString Access Read only Systems Management Software Feature Flags Name systemManagement SoftwareFeatureFlags Object ID 1 3 6 1 4 1 674 10892 1 100 11 Description Defines the features of the systems management software Syntax SMSFeatureFlags See Table 3 2 Access Read only 42 Systems Management Software Group Systems Management Software SNMP Agent Feature Flags Name Object ID Description Syntax Access systemManagementSoftwareSNMPAgentFeatureFlags 1 3 6 1 4 1 674 10892 1 100 12 Defines the features of the SNMP agent software provided by the operating system SMSSNMPAgentFeatureFlags See Table 3 3 Read only Systems Management Software Manufacturer Name Name Object ID Description Syntax Access systemManagementSoftwareManufacturerName 1 3 6 1 4 1 674 10892 1 100 13 Defines the manufacturer of the systems management software DellString Read only Systems Management Software Variable Values This section includes definitions of server administrator specific variable values used in this section Table 3 1 Systems Management Software Supported Standards Variable Nam
292. e remote access hardware has no control capabilities unknownCapabilities 1 The remote access hardware control capabilities are unknown 466 Remote Access Group Table 19 2 Remote Access Control Capabilities continued Variable Name De1 1RemoteAccessControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value logResetCapable 2 hardResetCapable 4 softResetCapable 8 The remote access hardware can reset its integrated logs The remote access hardware can perform a hard reset The remote access hardware can perform a soft reset gracefulResetCapable 16 The remote access hardware can gracefully shut down and perform a soft reset defaultConfigResetCapable 32 The remote access hardware can reset shutdownCapable 64 to its default settings The remote access hardware can shut down Table 19 3 Remote Access Control Settings Variable Name De 1 1RemoteAccessControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 unknown 1 logReset 2 hardReset 4 softReset 8 he remote access hardware has no control settings he remote access hardware control settings are unknown he remote access hardware will reset its integrated logs The remote access hardware will perform a hard reset The remote access hardware will perform a soft reset Remote Access Group
293. e reported by the powerUsagePeakWatts attribute was measured DellDateName Read only Power Usage Peak Amps Name Object ID Description Syntax Access powerUsagePeakAmps 1 3 6 1 4 1 674 10892 1 600 60 1 12 Defines the peak amperage reading in tenths of Amps for this entity since the date and time specified by the powerUsagePeakAmpsStartDateName attribute DellUnsigned32BitRange Read only Power Usage Peak Amps Start Date Name Name Object ID Description Syntax Access powerUsagePeakAmpsStartDateName 1 3 6 1 4 1 674 10892 1 600 60 1 13 Defines the date and time at which the data collection started for the value reported by the powerUsagePeakAmps attribute DellDateName Read only Power Group 169 Power Usage Peak Amps Reading Date Name Name powerUsagePeakAmpsReadingDateName Object ID 1 3 6 1 4 1 674 10892 1 600 60 1 14 Description Defines the date and time at which the value reported by the powerUsagePeakAmps attribute was measured Syntax DellDateName Access Read only Power Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 8 1 Power Supply State Capabilities Unique Variable Name De11PowerSupplyStateCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The power supply s capabilities are unknown onlineCapable 2 The power supply can be disabl
294. ead write Remote User Admin E Mail Address Name Name remoteUserAdminEmailAddressName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 27 Description Defines the e mail address for this remote access user Syntax DisplayString SIZE 0 63 Access Read write Remote User Admin E Mail Custom Message Name Name remoteUserAdminEmailCustomMessageName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 28 Description Defines the e mail message to send to this remote access user Syntax DisplayString SIZE 0 31 Access Read write 450 Remote Access Group Remote User Admin Control Capabilities Name Object ID Description Syntax Access remoteUserAdminControlCapabilities 1 3 6 1 4 1 674 10892 1 1700 20 1 29 Defines the control capabilities for this remote access user DellRemoteUserAdminControlCapabilities See Table 19 14 Read only Remote User Admin Control Settings Name Object ID Description Syntax Access remot eUserAdminControlSettings 1 3 6 1 4 1 674 10892 1 1700 20 1 30 Defines the control settings for this remote access user DellRemoteUserAdminControlSettings See Table 19 15 Read write Remote User Admin User Type Name remot eUserAdminUserType Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 31 Description Defines the type of user for this remote access user Syntax DellUnsigned8BitRange Access Read write Remote SNMP Trap Table Name remoteSNMPTrapTable Object ID 1 3 6 1 4 1 674 10892 1 1700 30 Desc
295. ed of cooling units Syntax DellObjectRange Access Read only Cooling Unit State Capabilities Name coolingUnitStateCapabilties Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 3 Description Defines the capabilities of the cooling unit Syntax DellStateCapabilities Access Read only Cooling Unit State Settings Name coolingUnitStateSettings Object ID 1 3 6 1 4 1 674 10892 1 700 10 1 4 Description Defines the state and settings of the cooling unit Syntax DellStateSettings Access Read write 182 Thermal Group Cooling Unit Redundancy Status Name Object ID Description Syntax Access coolingUnitRedundancyStatus 1 3 6 1 4 1 674 10892 1 700 10 1 5 Defines the redundancy status of the cooling unit DellStatusRedundancy Read only Cooling Device Count For Redundancy Name Object ID Description Syntax Access coolingDeviceCount ForRedundancy 1 3 6 1 4 1 674 10892 1 700 10 1 6 Defines the total number of cooling devices required for this cooling unit to have redundancy DellObjectRange Read only Cooling Unit Name Name Object ID Description Syntax Access coolingUnitName 1 3 6 1 4 1 674 10892 1 700 10 1 7 Defines the cooling unit name in this chassis DellString Read only Cooling Unit Status Name Object ID Description Syntax Access coolingUnitStatus 1 3 6 1 4 1 674 10892 1 700 10 1 8 Defines the status of the cooling unit in this chassis DellStatus Read only Thermal Grou
296. ed of this chassis DellObjectRange Read only Network Interface Control Index Name Object ID Description Syntax Access networkInterfaceControlIndex 1 3 6 1 4 1 674 10892 1 1400 80 1 2 Defines the index one based of the network interface controller in this chassis DellObjectRange Read only BIOS Setup Control Group 373 Network Interface Control Capabilities Unique Name networkIinterfaceControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 80 1 3 Description Defines the capabilities of the NIC Syntax DellNetworkInterfaceControlCapabilitiesUnique See Table 16 19 Access Read only Network Interface Control Settings Unique Name networkInterfaceControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 80 1 4 Description Defines the control settings for the NIC Syntax DellNetworkInterfaceControlSettingsUnique See Table 16 20 Access Read write Network Interface Control Status Name networkInterfaceControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 80 1 5 Description Defines the status of the NIC Syntax DellStatus Access Read only Network Interface Control Name Name networkInterfaceControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 80 1 6 Description Defines the setup BIOS name of the NIC Syntax DellString Access Read only 374 BIOS Setup Control Group BIOS Group Variable Values This section includes definitions for server administrator specific variable P v
297. ed offline a binary 0 value or enabled online a binary 1 value notReadyCapable 4 The power supply s capabilities are not ready Table 8 2 Power Supply State Settings Unique Variable Name De11PowerSupplyStateSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The power supply s capabilities are unknown onLine 2 The power supply s state is disabled offline a binary 0 value or enabled online a binary 1 value notReady 4 The power supply s state is not ready fanFailure 8 The power supply fan has failed 170 Power Group Table 8 2 Power Supply State Settings Unique continued Variable Name De11PowerSupplyStateSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value onlineAndFanFailure 10 powerSupplyIsON 16 powerSupplyIsOk 32 acSwitchIsON 64 onlineandAcSwitchIsON 66 acPowerIsON 128 onlineAndAcPowerIsON 130 onlineAndPredictiveFail ure 210 acPowerAndSwitchAreOn PowerSupplyIsOnIsOkAnd Online 242 The power supply is online and indicating that its fan is not working The power supply is indicating that it is on The power supply is indicating that it is OK The power supply is indicating that the AC power switch is on The power supply is online and indicating that the AC power supply switch capability is activated The power supply is indicating that the AC power
298. ed as an integer and has four possible values unknown lowSpeedCapable highSpeedCapable and lowOrHighSpeed Capable Section Organization Sections in this reference guide are based on the Server Administrator MIBs so the complexity of each section depends on the complexity of each MIB group The first section provides a high level introduction to the MIB group If the group is defined by one or more tables the second section lists these tables The third section documents the variables that comprise the group and if applicable the variables that comprise the tables The fourth section contains definitions for any Server Administrator specific variables that are used in the section The following example shows the typical content of these four sections 1 BIOS Setup Control Group This section explains the purpose of the MIB group and summarizes the major features of the component groups 2 BIOS Group Tables If there is more than one SNMP table for a group this section lists all of the tables For this BIOS group example there are eight tables listed In each section double clicking any table on the list takes you to that table 30 Introduction e BIOS Setup Control Table e SCSI Control Table e Parallel Port Control Table e Serial Port Control Table e USB Control Table e IDE Control Table e Diskette Control Table e Network Interface Control Table Variables that make up each table in the group This section documents
299. efines the index one based of this chassis DellObjectRange Read only System Resource Group 133 System Resource DMA Index Name systemResourceDMAIndex Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 2 Description Defines the index of system resource DMAs in this chassis Syntax DellObjectRange Access Read only System Resource DMA State Capabilities Name systemResourceDMAStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 3 Description Defines the capabilities of this system resource DMA Syntax DellStateCapabilities Access Read only System Resource DMA State Settings Name systemResourceDMAStateSettings Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 4 Description Defines the state and setting of this system resource DMA Syntax DellStateSettings Access Read write System Resource DMA Status Name systemResourceDMAStatus Object ID 1 3 6 1 4 1 674 10892 1 500 60 1 5 Description Defines the status of this system resource DMA Syntax DellStatus Access Read only 134 System Resource Group System Resource DMA Owner Index Reference Name Object ID Description Syntax Access systemResourceDMAOwnerIndexReference 1 3 6 1 4 1 674 10892 1 500 60 1 6 Defines the index to the associated system resource owner in this chassis DellObjectRange Read only System Resource DMA Share Disposition Name Object ID Description Syntax Access systemResourceDMAShareDisposition 1 3 6 1 4 1 674 108
300. efines the monitor capabilities of the remote access hardware Syntax DellRemoteAccessMonitorCapabilities See Table 19 4 Access Read only Remote Access Monitor Settings Name remoteAccessMonitorSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 13 Description Defines the monitor settings of the remote access hardware Syntax DellRemoteAccessMonitorSettings See Table 19 5 Access Read write Remote Access Local Area Network LAN Capabilities Name remoteAccessLANCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 14 Description Defines the LAN capabilities of the remote access hardware Syntax DellRemoteAccessLANCapabilities See Table 19 6 Access Read only Remote Access Group 437 Remote Access LAN Settings Name remoteAccessLANSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 15 Description Defines the LAN settings of the remote access hardware Syntax DellRemoteAccessLANSettings See Table 19 7 Access Read write Remote Access Host Capabilities Name remoteAccessHostCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 16 Description Defines the host capabilities of the remote access hardware Syntax DellRemoteAccessHostCapabilities See Table 19 8 Access Read only Remote Access Host Settings Name remoteAccessHostSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 17 Description Defines the host settings of the remote access hardware Syntax DellRemoteAccessHostSettings See Table 19 9
301. el LED to flash Syntax DellChassisIdentifyControlSettings See Table 5 10 Access Read write Chassis Lock Present Name chassisLockPresent Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 30 Description Specifies whether a chassis lock is present on the chassis Syntax DellBoolean Access Read only Chassis Host Control Capabilities Unique Name chassishostControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 31 Description Defines the capabilities of the host control object Syntax DellHostControlCapabilities See Table 5 11 Access Read only Chassis Information Group 73 Chassis Host Control Settings Unique Name chassishostControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 32 Description Defines the current settings of the host control object Syntax DellHostControlSettings See Table 5 12 Access Read write Chassis Watchdog Control Capabilities Unique Name chassiswatchDogControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 33 Description Defines the capabilities of the watchdog timer object Syntax DellWatchDogControlCapabilities See Table 5 13 Access Read only Chassis Watchdog Control Settings Unique Name chassiswatchDogControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 34 Description Defines the current settings and the values allowed to be set for the watchdog timer object Syntax DellWatchDogControlCapabilities See Table 5 13 Access Read writ
302. ent Group The Local Response Agent Group provides information about various attributes of your system s local response agent LRA The LRA allows systems managers to predetermine how a system running the server administrator will respond to a particular event type such as the loss of redundancy in a specific component or the elevation of temperature in a chassis Systems managers can configure the LRA to respond to an event type with a specific action When the condition of the critical component worsens the systems manager can escalate the response to make it more obvious to the operator For example when a voltage probe on a monitored machine reaches a warning condition the systems manager may want to notify the operator by causing the machine to beep When the voltage probe reaches failure the systems manager might want to have the system that has a failing component send a broadcast message to the management system and power off the troubled system LRA Group Tables The following management information base MIB tables define LRA variable attributes e LRA Global Settings Table e LRA Action Table LRA Global Settings The global settings table allows the systems manager to determine what LRA capabilities exist for a specific system that is running Server Administrator Some machines may support all or some of the capabilities described in DellLocalResponseAgentCapabilities Unique The LRA Global Settings Table also defines th
303. environment A CIM schema is a collection of class definitions used to represent managed objects that are common to every management environment which is why CIM is called the Common Information Model 714 Glossary SCSI Acronym for small computer system interface An I O bus interface with faster data transmission rates than standard ports You can connect up to seven devices 15 for some newer SCSI types to one SCSI interface SDMS Abbreviation for SCSI device management system sec Abbreviation for second s SEC Abbreviation for single edge contact serial port An I O port used most often to connect a modem to your computer You can usually identify a serial port on your computer by its 9 pin connector settings Settings are conditions of a manageable object help to determine what happens when a certain value is detected in a component For example a user can set the upper critical threshold of a temperature probe to 75 degrees Celsius If the probe reaches that temperature the setting results in an alert being sent to the management console so that user intervention can be taken Some settings when reached can trigger a system shutdown or other response that can prevent damage to the system service tag number A bar code label on the computer that identifies it when you call Dell for customer or technical support SGRAM Acronym for synchronous graphics RAM shadowing A computer s system and video BIOS code
304. er in the table corresponds to that enclosure instance in the Enclosure Table Battery Table describes available properties for each controller battery on the managed system e Battery Connection Table describes the connection between each battery on the managed system and its controller Each controller number in the table corresponds to that controller instance in the Controller Table Controller Table This table describes available properties for each controller on the managed system The following object sets up the Controller Table Name controllerTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 Description Defines the controller table which is a table of managed Redundant Array of Independent disks RAID controllers The number of entries is related to the number of RAID controllers discovered in the system Syntax SEQUENCE OF ControllerEntry Access Not accessible Storage Management Group 517 Controller Entry Name controllerEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 Description Defines the controller table entry which is an entry in the table of RAID controllers A row in this table cannot be created or deleted by SNMP operations on columns of the table Syntax ControllerEntry Access Not accessible Index controllerNumber Controller Number Name controllerNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 1 Description Identifies the instance number of the controller entry Syntax
305. er name for this chassis Syntax DellString Access Read write 70 Chassis Information Group Chassis System User Phone Number Name Name chassisSystemUserPhoneNumberName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 20 Description Defines the user assigned phone number of the primary user of the system Syntax DellString Access Read write Chassis Connection Status Unique Name chassisConnectionStatusUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 21 Description Defines the status of the connection from the system chassis to an expansion chassis Syntax DellConnectionStatus See Table 5 3 Access Read only Chassis Fan Control Capabilities Unique Name chassisFanControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 22 Description Defines the capabilities of the fan control function in this chassis Syntax DellFanControlCapabilities See Table 5 4 Access Read only Chassis Fan Control Settings Unique Name chassisFanControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 23 Description Defines the readings and settings of the fan control hardware in the chassis Syntax DellFanControlSettings Access Read write Chassis Information Group 71 Chassis LED Control Capabilities Unique Name Object ID Description Syntax Access chassisLEDControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 300 10 1 24 Defines the capabilities of the LED control function in the chassis DellLEDCon
306. ermal shutdown capabilities and settings In the event that a temperature probe determines the temperature is at or over the failure limit the systems manager can set an action to be taken automatically Local Response Agent Group 385 LRA Global Settings Table Name 1RAGlobalSettingsTable Object ID 1 3 6 1 4 1 674 10892 1 1500 10 Description Defines the LRA Global Settings Table Syntax SEQUENCE OF LRAGlobalSettingsTableEntry Access Not accessible LRA Global Settings Table Entry Name 1RAGlobalSettingsTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1500 10 1 Description Defines the LRA Global Settings Table entry Syntax LRAGlobalSettingsTableEntry Access Not accessible Index IRAGlobalchassisIndex LRA Global Chassis Index Name 1RAGlobalchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1500 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only LRA Global State Name 1RAGlobalState Object ID 1 3 6 1 4 1 674 10892 1 1500 10 1 2 Description Defines the state of the LRA global settings Syntax DellStateSettings Access Read only 386 Local Response Agent Group LRA Global Settings Disable Time out Value Name Object ID Description Syntax Access 1RAGlobalSettingsDisableTimeoutValue 1 3 6 1 4 1 674 10892 1 1500 10 1 3 Defines the time out duration countdown in seconds that the LRA global settings will be disabled after a system shutdown and reboot DellU
307. ershipString Access Read write Cost of Ownership Group 401 COO Operating System Upgrade Type Name Name cooOperatingSystemUpgradeTypeName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 32 Description Defines the name of the operating system on this system Syntax DellCostofOwnershipString Access Read write COO Operating System Upgrade Patch Level Name Name cooOperatingSystemUpgradePat chLevelName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 33 Description Defines the name of the operating system patch level for this system Syntax DellCostofOwnershipString Access Read write COO Operating System Upgrade Date Name cooOperatingSystemUpgradeDate Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 34 Description Defines the upgrade file date for this operating system Syntax DellCostofOwnershipString Access Read write COO Depreciation Duration Name cooDepreciationDuration Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 35 Description Defines the length of depreciation for this system Syntax DellUnsigned32BitRange Access Read write 402 Cost of Ownership Group COO Depreciation Duration Type Name Object ID Description Syntax Access cooDepreciationDurationType 1 3 6 1 4 1 674 10892 1 1600 10 1 36 Defines the unit of time for the depreciation of this system DellCooMonthYearDuration Type Read write COO Depreciation Percentage Name Object ID Description Syntax Access cooDepreciationPercentage 1 3
308. erver 1 3 6 1 4 1 674 10892 1 100 2 0 5 3 0 1 3 6 1 4 1 674 10892 1 100 3 0 4522 1 3 6 1 4 1 674 10892 1 100 4 0 Management software for Dell systems 1 3 6 1 4 1 674 10892 1 100 5 0 1 dee 3s n HA Oo 4 1 4 1 674 10892 1 100 6 0 1 4 1 3 6 1 4 1 674 10892 1 100 7 0 No Updates 1 3 6 1 4 1 674 10892 1 100 8 0 https 1 2 3 4 1311 1 3 6 1 4 1 674 10892 1 100 9 0 en US SNMP Sample Output 683 dias I w w W W U U U U U WW UW 3 Oi Caa Hn DH HHH HH HHH HW DW 6 lye alee Be A FF FF FF FF FPF FF FF FPF A A HP BD 4 mb il 674 674 674 674 674 674 674 674 674 674 674 674 674 674 674 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 10892 1 1 100 100 100 100 200 200 200 200 200 200 200 200 200 200 200 10 TEL T24 T3 10 10 10 LO 10 1g KOs 10 10 10 LO 1 al a LOs S ape raag 0 1 Dell Inc Il 1 3 2 3 02 3 03 02 02 3 03 03 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 02 1 3 6 1 4 1 674 10892 1 200 10 1 12 1 1 3 6 1 4 1 674 10892 1 200 10 1 13 1 3 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 03 1 3 6 1 4 1 674 10892 1 02 02 02 02 02 1 3 6 1 4 1 674 10892 1
309. es Variable Name De1 1MemoryDevicePortConnectorType Data Type Integer Possible Data Value Meaning of Data Value connectorPortTypelIsOther 1 The memory device port connector type is not one of the following connectorPortTypelIsUnknown 2 The memory device port connector type is unknown connectorPortTypeIsSIMM 3 The memory device port connector type is a single in line memory module SIMM connectorPortTypeIsSIP 4 The memory device port connector type is a SIP connectorPortTypelIsAChip 5 The memory device port connector type is a chip connectorPortTypeIsDIP 6 The memory device port connector type is a dual in line package DIP connectorPortTypeIsZIP 7 The memory device port connector type is a ZIP connectorPortTypelIsAProprietaryCard 8s The memory device port connector type is a proprietary card connectorPortTypeIsDIMM 9 The memory device port connector type is a dual in line memory module DIMM connectorPortTypeIsTSOP 10 The memory device port connector type is a TSOP connectorPortTypeIsARowOfChips 11 The memory device port connector type is a row of chips 240 Port Group Table 12 4 Memory Device Port Connector Types continued Variable Name De1 1MemoryDevicePortConnectorType Data Type Integ er Possible Data Value Meaning of Data Value connectorPort TypeIsRIMM 12 connectorPortTypeIsSODIMM 13 connectorPortTypeIsSRIM
310. es Meaning of Data Value unknown 1 The LED control capabilities are unknown alertOnErrorCapable 2 The LED control can be set to alert on an error condition alertOnWarningAndErrorCap The LED control can be set to alert on an able 4 error and a warning condition alertOnWarningOrErrorCapa The LED control can be set to alert on an ble 6 error or a warning condition Table 5 6 Front Panel LED Control Settings Variable Name De1 LLEDControlSettings Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The LED control setting is unknown alertOnError 2 The LED control is set to alert on an error condition alertOnWarningAndError 4 The LED control is set to alert on an error or a warning condition 102 Chassis Information Group Table 5 7 Hard Drive Fault LED Control Capabilities Variable Name De1 1HDFaultLEDControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The hard drive has no fault LED capabilities unknownCapabilities 1 The hard drive fault LED capabilities are unknown enableCapable 2 he hard drive fault LED can be disabled offline a binary 0 value or enabled online a binary 1 value notReadyCapable 4 The hard drive fault LED can indicate not ready resetCapable 8 The hard drive fault LED can be reset Table 5 8 Hard Drive Fault LED Control Settings Variable Name De1 LHDFa
311. es the array disk logical connection table Syntax SEQUENCE OF arrayDiskLogicalConnectionEntry Access Not accessible Array Disk Logical Connection Entry Name arrayDiskLogicalConnectionEntry Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 Description Defines the array disk logical connection table entry Syntax ArrayDiskLogicalConnectionEntry Access Not accessible Index arrayDiskLogicalConnectionNumber Array Disk Logical Connection Number Name arrayDiskLogicalConnectionNumber Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 1 Description Identifies the instance number of the disk entry Syntax Integer Access Read only Array Disk Logical Connection Array Disk Name Name arrayDiskLogicalConnectionArrayDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 2 Description Identifies the name of the array disk in this logical connection Syntax DisplayString Access Read only 614 Storage Management Group Array Disk Logical Connection Array Disk Number Name arrayDiskLogicalConnectionArrayDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 3 Description Identifies the instance number of the array disk in this logical connection Syntax Integer Access Read only Array Disk Logical Connection Virtual Disk Name Name arrayDiskLogicalConnectionVirtualDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 140 3 1 4 Description Identifies the name of the virtual disk to which this array disk belongs Syntax DisplayString Access Read
312. escription Defines the state of the numeric lock Syntax DellStateSettings Access Read only BIOS Setup Control Group 351 BIOS Setup Control Numeric Lock Control Status Name bSUCnumLockControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 8 Description Defines the status of the numeric lock Syntax DellStatus Access Read only BIOS Setup Control Numeric Lock Control Name Name bsSUCnumLockControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 9 Description Defines the setup BIOS name of the numeric lock Syntax DellString Access Read only BIOS Setup Control Processor Serial Number Control Capabilities Name bSUCprocessorSerialNumberControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 10 Description Defines if the processor serial number can be returned Syntax DellStateCapabilities Access Read only BIOS Setup Control Processor Serial Number Control Settings Name bSUCprocessorSerialNumberControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 11 Description Defines the state of the processor serial number Syntax DellStateSettings Access Read only 352 BIOS Setup Control Group BIOS Setup Control Processor Serial Number Control Status Name bSUCprocessorSerialNumberControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 12 Description Defines the status of the processor serial number Syntax DellStatus Access Read only BIOS Setup Control Processor Serial Number Control Name Name bSU
313. esource Name Object ID Description Syntax Access 120 systemResourceMapTableEntry 1 3 6 1 4 1 674 10892 1 500 10 1 Defines the System Resource Map Table entry SystemResourceMap LableEntry Not accessible systemResourceMapchassisIndex systemResourceMapIndex Map Chassis Index systemResourceMapChassisIndex 1 3 6 1 4 1 674 10892 1 500 10 1 1 Defines the index one based of this chassis DellObjectRange Read only Map Index systemResourceMapIndex 1 3 6 1 4 1 674 10892 1 500 10 1 2 Defines the index of system resource maps in this chassis DellObjectRange Read only Map State Capabilities systemResourceMapStateCapabilities 1 3 6 1 4 1 674 10892 1 500 10 1 3 Defines the capabilities of this system map DellStateCapabilities Read only System Resource Group System Resource Map State Settings Name systemResourceMapStateSettings Object ID 1 3 6 1 4 1 674 10892 1 500 10 1 4 Description Defines the state and allows the setting of this system map Syntax DellStateSettings Access Read write System Resource Map Status Name systemResourceMapStatus Object ID 1 3 6 1 4 1 674 10892 1 500 10 1 5 Description Defines the status of this system map Syntax DellStatus Access Read only System Resource Map Type Name systemResourceMapTyp Object ID 1 3 6 1 4 1 674 10892 1 500 10 1 6 Description Defines the type of this system map Syntax DellSystemResourceMapType See Table 7 1 Access Read only System
314. ess applied to the device ZIP A 3 5 inch removable disk drive from Iomega Originally it provided a 100 MB removable cartridges The drive is bundled with software that can catalog the disks and lock the files for security A250 MB version of the Zip drive also reads and writes the 100 MB Zip cartridges 726 Glossary Index Numerics 1403 653 1404 653 1602 657 1603 657 1604 658 1651 658 1652 659 1653 659 A Application 622 Application Group 622 BIOS Group BIOS Setup Control Table 349 Diskette Control Table 370 IDE Control Table 368 Network Interface Control Table 372 Parallel Port Control Table 362 SCSI Control Table 360 Serial Port Control Table 364 USB Control Table 366 BIOS Group tables 349 BIOS Setup Control Group 349 variable values 375 c Change 619 Change Management Group 619 Chassis Information Group tables 65 Chassis Information Table 65 Event Log Table 81 Firmware Table 90 Intrusion Table 93 95 POST Log Table 79 System BIOS Table 84 UUID Table 77 Variable Values 100 Cluster Group 483 Cluster Table 483 variable values 486 Cost of Ownership Group COO Cost Event Log Table 06 COO Lease Information Table 410 COO Maintenance Table 416 COO Options Table 14 COO Repair Table 418 COO Schedule Number Table 413 COO Service Contract Table 404 Index 727 COO Support Information Table 420 COO Trouble Ticket Table 422 COO Warranty
315. eted by your computer BMC Abbreviation for baseboard management controller which is a controller that provides the intelligence in the IPMI structure boot routine When you start your computer it clears all memory initializes devices and loads the operating system Unless the operating system fails to respond you can reboot also called warm boot your computer by pressing lt Ctrl gt lt Alt gt lt Del gt otherwise you must perform a cold boot by pressing the reset button or by turning the computer off and then back on bootable diskette You can start your computer from a diskette To make a bootable diskette insert a diskette in the diskette drive type sys a at the command line prompt and press lt Enter gt Use this bootable diskette if your computer will not boot from the hard drive bpi Abbreviation for bits per inch Glossary 691 bps Abbreviation for bits per second BTU Abbreviation for British thermal unit bus An information pathway between the components of a computer Your computer contains an expansion bus that allows the microprocessor to communicate with controllers for all the various peripheral devices connected to the computer Your computer also contains an address bus and a data bus for communications between the microprocessor and RAM byte Eight contiguous bits of information the basic data unit used by your computer c Abbreviation for Celsius cache A fast storage area tha
316. eup on LAN Setup BIOS is capable of enabling Wakeup on LAN by option card Setup BIOS is capable of enabling Wakeup on LAN by integrated NIF Setup BIOS is capable of enabling Wakeup on LAN by either option card or integrated NIE Table 16 4 NIF Wakeup on LAN Control Settings Unique Variable Name De1 INI FwakeonLanControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 enabled 2 addiInCard 4 onBoard 8 addiInCardOrOnBoard 12 NIF Wakeup on LAN state is unknown NIF Wakeup on LAN is enabled NIF Wakeup on LAN is by option card NIF Wakeup on LAN is by integrated NIF NIF Wakeup on LAN is by option card or integrated NIE 376 BIOS Setup Control Group Table 16 5 Boot Sequence Control Capabilities Unique Variable Name De 1 1Boot SequenceControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value boot SequenceUnknown 1 Boot sequence capabilities are unknown boot FromDisketteFirstCapable Setup BIOS can boot from a diskette 2 first bootFromhardDriveFirstCapable Setup BIOS can boot from an IDE hard 4 drive first bootFromDisketteORHardDrive Setup BIOS can boot from a diskette or FirstCapable 6 an IDE hard drive first boot FromDeviceListCapable 8 Setup BIOS can boot from a device list boot FromCDROMFirstCapable 16 Setup BIOS can boot from a CD first allFirstCapable 30 Setup BIOS can
317. evice may have been added to the system incorrectly The device location chassis location and additional event details if available are provided Traps 659 Battery Traps The BMC on some systems reports the status of batteries Battery traps provide status and warning information for batteries present in a system with a BMC that reports the status of batteries Table 25 16 Battery Traps Trap ID Description Severity Cause Battery Normal 1702 Battery sensor returned Information to a normal value Sensor Location lt Location in chassis gt Chassis Location lt Name of chassis gt Previous state was lt State gt Battery sensor status lt status gt Battery Warning 1703 Battery sensor detected Warning a warning value Sensor Location lt Location in chassis gt Chassis Location lt Name of chassis gt Previous state was lt State gt Battery sensor status lt status gt 660 Traps A battery sensor in the specified system detected that a battery transitioned back to a normal state The sensor location chassis location previous state and battery sensor status are provided A battery sensor in the specified system detected that a battery is ina predictive failure state The sensor location chassis location previous state and battery sensor status are provided Table 25 16 Battery Traps Trap ID Description Severity Cause Battery Failure 1704 Bat
318. eviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 50 1 Defines the Memory Device Table entry MemoryDeviceTableEntry Not accessible memoryDevicechassisIndex memoryDeviceIndex Memory Device Chassis Index Name Object ID Description Syntax Access memoryDevicechassisIndex 1 3 6 1 4 1 674 10892 1 1100 50 1 1 Defines the index one based of this chassis DellObjectRange Read only Memory Device Index Name Object ID Description Syntax Access memoryDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 50 1 2 Defines the index of the memory device in this chassis DellObjectRange Read only Device Group 265 Memory Device State Capabilities Name Object ID Description Syntax Access memoryDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 50 1 3 Defines the capabilities of the memory device DellStateCapabilities Read only Memory Device State Settings Name Object ID Description Syntax Access memoryDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 50 1 4 Defines the state of the memory device DellStateSettings Read write Memory Device Status Name Object ID Description Syntax Access memoryDeviceStatus 1 3 6 1 4 1 674 10892 1 1100 50 1 5 Defines the status of the memory device DellStatus Read only Memory Device Memory Port Index Reference Name Object ID Description Syntax Access 266 memoryDeviceMemoryPort IndexReference 1 3 6 1 4 1 674 10892 1 1100 50 1 6
319. eyboardDeviceStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 4 Description Defines the state of the keyboard device Syntax DellStatesSettings Access Read write Keyboard Device Status Name keyboardDeviceStatus Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 5 Description Defines the status of the keyboard device Syntax DellStatus Access Read only Device Group 247 Keyboard Port Index Reference Name keyboardPort IndexReference Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 6 Description Defines the index to the associated the keyboard port in this chassis Syntax DellStatus Access Read only Keyboard Device Type Name Name keyboardDeviceTypeName Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 7 Description Defines the name of the keyboard type Syntax DellString Access Read only Keyboard Device Layout Name Name keyboardDeviceLayoutName Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 8 Description Defines the name of the keyboard layout Syntax DellString Access Read only Processor Device Table Name processorDeviceTable Object ID 1 3 6 1 4 1 674 10892 1 1100 30 Description Defines the Processor Device Table Syntax SEQUENCE OF ProcessorDeviceTableEntry Access Not accessible 248 Device Group Processor Device Table Entry Name Object ID Description Syntax Access Index processorDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 30 1 Defines the Processor Device Table entry ProcessorDeviceT
320. factor is a chip Device form factor is DIP Device form factor is ZIP deviceFormFactorIsAProprietaryCard Device form factor is a proprietary 8 card deviceFormFactorIsDIMM 9 Device form factor is DIMM deviceFormFactorIsTSOP 10 Device form factor is TSOP 304 Device Group Table 13 15 Memory Device Type Form Factor continued Variable Name De 1 1MemoryDeviceFormFactor Data Type Integer Possible Data Values Meaning of Data Value deviceFormFac deviceFormFac deviceFormFac deviceFormFac deviceFormFac torIsRIMM 12 torIsSODIMM 13 torIsSRIMM 14 torIsFBDIMM 15 torIlsARowOfChips 11 Device form factor is a row of chips Device form factor is RIMM Device form factor is SODIMM Device form factor is SRIMM Device form factor is FB DIMM Table 13 16 Memory Device Type Variable Name De1 1MemoryDeviceType Data Type Integer Possible Data Values Meaning of Data Value deviceTypelIsOther 1 deviceTypelIsUnknown 2 deviceTypeIsDRAM 3 deviceTypelIsEDRAM 4 deviceTypeIsVRAM 5 deviceTypeIsSRAM 6 deviceTypeIsRAM 7 deviceTypeIsROM 8 deviceTypeIsFLASH 9 deviceTypeIsEEPROM 10 deviceTypeIsFEPROM 11 deviceTypeIsEPROM 12 deviceTypeIsCDRAM 13 deviceTypelIs3DRAM 14 Device type is not one of the following Device type is unknown Device type is DRAM Device type is EDRAM Device type is VRAM Device type is SRAM
321. fan on an integrated circuit coolingDeviceTypelIsACabinetFan 6 The cooling device type is a cabinet fan coolingDeviceTypeIsAPowerSupplyFan 7 The cooling device type is a power supply fan coolingDeviceTypelIsAHeat Pipe 8 The cooling device type is a heat pipe coolingDeviceTypelIsRefrigeration 9 The cooling device type is an integrated refrigeration unit coolingDeviceTypeIsActiveCooling 10 The cooling device type is an active cooling device coolingDeviceTypelIsPassiveCooling 11 The cooling device type is a g yp g yp passive cooling device ThermalGroup 195 Table 9 2 Cooling Device Subtype Variable Name De 1 1CoolingDeviceSubType Data Type Integer Possible Data Values Meaning of Data Value coolingDeviceSubTypeIsOther 1 The cooling device subtype is not one of the following coolingDeviceSubTypeIsUnknown 2 The cooling device subtype is unknown not known or not monitored coolingDeviceSubTypeIsAFanThatReads The cooling device subtype is a InRPM 3 fan that reads in RPMs coolingDeviceSubTypeIsAFanReadsONor The cooling device subtype is a OFF 4 fan that reads 0 off or 1 on coolingDeviceSubTypeIsAPowerSupply The cooling device subtype is a FanThatReadsinRPM 5 power supply fan that reads in RPMs coolingDeviceSubTypeIsAPowerSupply The cooling device subtype is a FanThatReads ONorOFF 6 power supply fan that reads 0 off or 1 on coolingDevi
322. fields 25 26 managed object 25 MIB 25 SNMP 24 variable 25 SNMP support configuring 675 730 Index SNMP tables 27 example 28 reference guide content 29 35 SNMP traps 676 Storage Management Event Group 616 Storage Management Information Group 509 System Resource Group Direct Memory Access Table 133 Input Output Port Table 124 Interrupt Table 130 Map Table 119 Memory Table 127 Owner Table 121 variable values 136 System State Table 45 313 systems management software 40 build number systems 40 description name 41 name 40 42 preferred protocol 41 supported protocol 41 version number name 40 T Thermal Group Cooling Device Table 183 Cooling Unit Table 181 Temperature Probe Table 189 variable values 195 trap variables 630 Vv current status 631 data 631 message 630 variable names capability 27 settings 27 previous status 631 6 tate 27 system 630 ron 7 table index OID 630 Viewing traps 636 AC power cord traps 655 amperage probe traps 644 chassis intrusion traps 647 SNMP traps 676 cooling device traps 640 fan enclosure traps 654 hardware log traps 656 memory device traps 652 miscellaneous traps 637 power supply traps 650 redundancy unit traps 648 temperature probe traps 638 understanding the trap descriptions 632 understanding trap severity 636 voltage probe traps 642 U User Security Table 199 203 Index
323. for example Pre failure state was Failed Specifies the status of the previous redundancy message for example Previous redundancy state was Lost Specifies the previous state of the sensor for example Previous state was OK Normal Specifies the status of the processor sensor for example Processor sensor status Configuration error Specifies the location of the redundant power supply or cooling unit in the chassis for example Redundancy unit Fan Enclosure Specifies the location of the sensor in the specified chassis for example Sensor location CPU1 Specifies the temperature in degrees Celsius for example Temperature sensor value in degrees Celsius 30 Specifies the voltage sensor value in volts for example Voltage sensor value 1 693 Traps 635 Understanding Trap Severity Traps often contain information about values recorded by probes or sensors Probes and sensors monitor critical components for values such as amperage voltage and temperature When an event occurs on your system the Server Administrator sends information about one of the following event types to the system management console Information Informational An event that describes the successful operation of a unit such as a power supply turning on or a sensor reading returning to normal e Warning An event that is not necessarily significant but may indicate a possible future problem such as
324. for the first through third parallel printer ports on your computer are LPT 1 LPT2 and LPT LRA Acronym for local response agent m Abbreviation for meter s mA Abbreviation for milliampere s mAh Abbreviation for milliampere hour s math coprocessor See coprocessor Mb Abbreviation for megabit MB Abbreviation for megabyte s The term megabyte means 1 048 576 bytes however when referring to hard drive storage the term is often rounded to mean 1 000 000 bytes MB sec Abbreviation for megabytes per second Glossary 705 Mbps Abbreviation for megabits per second MBR Abbreviation for master boot record MCA Abbreviation for Micro Channel Architecture which is designed for multiprocessing MCA eliminates potential conflicts that arise when installing new peripheral devices MCA is not compatible with either EISA or XT bus architecture so older cards cannot be used with it memory A computer can contain several different forms of memory such as RAM ROM and video memory Frequently the word memory is used as a synonym for RAM for example an unqualified statement such as a computer with 16 MB of memory refers to a computer with 16 MB of RAM memory address A specific location usually expressed as a hexadecimal number in the computer s RAM memory manager Autility that controls the implementation of memory in addition to conventional memory such as extended or expanded memory mem
325. functional For example a Warning Non critical alert may indicate that a component such as a temperature probe in an enclosure has crossed a warning threshold Critical Failure Error A component has either failed or failure is imminent This alert indicates a serious problem such as data loss or a loss of function For example a Critical Failure Error alert may indicate that an array disk has failed 674 Storage Management Alert Reference SNMP Support for Storage Management Alerts By default Storage Management installs SNMP trap forwarding support For this support to function you should have SNMP installed on the managed system prior to installing Storage Management K NOTE For more information on installation requirements and SNMP see the Server Administrator documentation SNMP Trap Forwarding The Storage Management alerts are displayed in the Server Administrator alert log and are forwarded to the Windows application alert log If you have SNMP installed on the managed system and the SNMP service is running the Storage Management alerts in the Windows application alert log will be forwarded as SNMP traps In order for these traps to be viewable however a target system or application must be configured to receive these traps SNMP traps that are generated by Storage Management can be viewed in any standard SNMP compatible enterprise management console The Windows SNMP service must be configured to forward the SNM
326. g Device Upper Critical Threshold Name coolingDeviceUpperCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 10 Description Defines the value of the fan s upper critical threshold Syntax DellSigned32BitRange Access Read only Cooling Device Upper Noncritical Threshold Name coolingDeviceUpperNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 11 Description Defines the user assigned value of the fan s upper noncritical threshold Syntax DellSigned32BitRange Access Read write Cooling Device Lower Noncritical Threshold Name coolingDeviceLowerNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 12 Description Defines the user assigned value of the fan s lower noncritical threshold Syntax DellSigned32BitRange Access Read write ThermalGroup 187 Cooling Device Lower Critical Threshold Name Object ID Description Syntax Access coolingDeviceLowerCriticalThreshold 1 3 6 1 4 1 674 10892 1 700 12 1 13 Defines the value of the fan s lower critical threshold DellSigned32BitRange Read only Cooling Device Lower Nonrecoverable Threshold Name Object ID Description Syntax Access coolingDeviceLowerNonRecoverableThreshold 1 3 6 1 4 1 674 10892 1 700 12 1 14 Defines the value of the fan s lower nonrecoverable threshold DellSigned32BitRange Read only Cooling Device Cooling Unit Index Reference Name Object ID Description Syntax Access coolingDevicec
327. guration change Because the System Setup program is stored in NVRAM any settings remain in effect until you change them again system ini file A start up file for the Windows operating system When you start Windows it consults the system ini file to determine a variety of options for the Windows operating environment Among other things the system ini file records which video mouse and keyboard drivers are installed for Windows Running the Control Panel or Windows Setup program may change options in the system ini file On other occasions you may need to change or add options to the system ini file manually with a text editor such as Notepad 718 Glossary table In SNMP MIBs a table is a two dimensional array that describes the variables that make up a managed object TCP IP Abbreviation for Transmission Control Protocol Internet Protocol A system for transferring information over a computer network containing dissimilar systems such as systems running Windows and UNIX termination Some devices such as the last device at each end of a SCSI cable must be terminated to prevent reflections and spurious signals in the cable When such devices are connected in a series you may need to enable or disable the termination on these devices by changing jumper or switch settings on the devices or by changing settings in the configuration software for the devices text editor An application program for editing text files consi
328. he octet string represents the status of a specific current probe The first byte returned represents the state of the first current probe the second byte returned represents the state of the second current probe and so on The bytes have the same definition type as DellStateSettings Syntax OCTET STRING SIZE 1 128 Access Read only System State Amperage Status Combined Name systemStateAmperageStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 15 Description Defines the status of all amperage probes in this chassis The result is returned as a combined status value The value has the same definition type as DellStatus Syntax DellStatus Access Read only System State Amperage Status Details Name systemStateAmperageStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 16 Description Defines the status of all amperage probes in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific amperage probe The first byte returned represents the status of the first amperage probe the second byte returned represents the status of the second amperage probe and so on The bytes have the same definition type as DellStatus Syntax OCTET STRING SIZE 1 128 Access Read only 50 System State Group System State Cooling Unit State Details Name Object ID Description Syntax Access statesystemStateCoolingUnitStateDetails 1 3 6 1 4 1 6
329. he status of the physical memory logging DellStatus Read only Redundant Memory Unit Table This table reports the status of redundant memory within a particular system chassis The following object sets up the Redundant Memory Unit Table Name Object ID Description Syntax Access redundantMemoryUnitTable 1 3 6 1 4 1 674 10892 1 1300 50 Defines the Redundant Memory Unit Table SEQUENCE OF RedundantMemoryUnitTableEntry Not accessible Memory Group 337 Redundant Memory Unit Table Entry Name Object ID Description Syntax Access Index redundantMemoryUnitTableEntry 1 3 6 1 4 1 674 10892 1 1300 50 1 Defines the Redundant Memory Unit Table entry RedundantMemoryUnitTableEntry Not accessible redundantMemoryUnitChassisIndex redundantMemoryUnitIndex Redundant Memory Unit Chassis Index Name Object ID Description Syntax Access redundantMemoryUnitChassisIndex 1 3 6 1 4 1 674 10892 1 1300 50 1 1 Defines the index one based of the chassis associated with the redundant memory unit DellObjectRange Read only Redundant Memory Unit Index Name Object ID Description Syntax Access redundantMemoryUnit Index 1 3 6 1 4 1 674 10892 1 1300 50 1 2 Defines the index one based of the redundant memory unit DellObjectRange Read only Redundant Memory Unit State Capabilities Name Object ID Description Syntax Access 338 redundantMemoryUnitStateCapabilities 1 3 6 1 4 1 674
330. he variable is known in the MIB MIB variables are named according to the following conventions Variable names start with a lowercase letter Spaces are not allowed between words in the variable name Acronyms are in uppercase letters except when an acronym 1s the first word in the variable name e With the exception of the first letter of the variable name and acronyms all other words in the variable name start with capital letters The following variable names illustrate these conventions temperatureProbeLowerCriticalThreshold coolingUnitIndex pCIDeviceSpeed Object Identifier OID is the unique number assigned to an object defined ina MIB An OID is written as a sequence of subidentifiers in decimal notation Each OID in this reference guide has a prefix that identifies the managed objects as belonging to Dell 1 3 6 1 4 1 674 The additional numbers identify the MIB group and subgroup as well as the table entry number of any variables For example the OID for the temperature probe managed object table is 700 20 and the variable for the location of the temperature probe temperatureProbeLocationName has an OID of 700 20 1 8 The full OIDs for these items are 1 3 6 1 4 1 674 10892 1 700 20 for the temperatureProbe Table and 1 3 6 1 4 1 674 10892 1 700 20 1 8 for the temperatureProbeLocation For more information about the structure of OIDs see SNMP MIB OIDs Description is a brief explanation of what a
331. ial Up Table Name Object ID Description Syntax Access remoteDialUpTable 1 3 6 1 4 1 674 10892 1 1700 40 Defines the Remote Access Dial Up Table SEQUENCE OF RemoteDialUpTableEntry Not accessible Remote Dial Up Table Entry Name Object ID Description Syntax Access Index remoteDialUpTableEntry 1 3 6 1 4 1 674 10892 1 1700 40 1 Defines the Remote Access Dial Up Table entry RemoteDialUpTableEntry Not accessible remoteDialUpChassisIndex remoteDialUpAdapterIndex remoteDialUpIndex Remote Dial Up Chassis Index Name Object ID Description Syntax Access remoteDialUpChassisIndex 1 3 6 1 4 1 674 10892 1 1700 40 1 1 Defines the index one based of the chassis containing the remote access hardware DellObjectRange Read only 456 Remote Access Group Remote Dial Up Adapter Index Name Object ID Description Syntax Access remoteDialUpAdapterIndex 1 3 6 1 4 1 674 10892 1 1700 40 1 2 Defines the index one based of the remote access hardware that supports this remote access dial up functionality DellObjectRange Read only Remote Dial Up Index Name Object ID Description Syntax Access remoteDialUpIndex 1 3 6 1 4 1 674 10892 1 1700 40 1 3 Defines the index one based of this remote access dial up functionality DellObjectRange Read only Remote Dial Up State Capabilities Name Object ID Description Syntax Access remoteDialUpStateCapabilities
332. iation PCMCIA Info Name Name remoteAccessPCMCIAInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 28 Description Defines the information for the PCMCIA device used by the remote access hardware Syntax DisplayString SIZE 0 63 Access Read only Remote Access Group 431 Remote Access Miscellaneous Information Name Name remoteAccessMiscInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 29 Description Defines the miscellaneous information for the remote access hardware Syntax DisplayString SIZE 0 63 Access Read write Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read only Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 31 Description Defines the netmask currently being used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read only Remote Access NIC Current Gateway Address Name remoteAccessNICCurrentGatewayAddress Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 32 Description Defines the IP address for the gateway currently being used by the integrated NIC provided by the remote access hardware Syntax IpAddress Access Read only 432 Remote Access Group Remote
333. iation for Fahrenheit FAT Acronym for file allocation table The Windows NT operating systems can optionally use a FAT file system structure FCC Abbreviation for Federal Communications Commission Glossary 699 FEPROM Acronym for Flash Erasable Programmable Read Only Memory Flash memory is a kind of non volatile storage device similar to EEPROM but the erasing is done only in blocks or the entire chip flash BIOS A PC BIOS that is stored in flash memory rather than in a ROM A flash BIOS chip can be updated in place whereas a ROM BIOS must be replaced with a newer chip flash memory A type of EEPROM chip that can be reprogrammed from a utility on diskette while still installed in a computer most EEPROM chips can only be rewritten with special programming equipment format To prepare a hard drive or diskette for storing files An unconditional format deletes all data stored on the disk FPBGA Acronym for field programmable gate array a programmable logic chip PLD with a high density of gates FRU Acronym for field replaceable unit ft Abbreviation for feet FTP Abbreviation for file transfer protocol Abbreviation for gram s G Abbreviation for gravities GB Abbreviation for gigabyte s A gigabyte equals 1 024 megabytes or 1 073 741 824 bytes 700 Glossary graphics coprocessor See coprocessor graphics mode A video mode that can be defined as x horizontal by y vertical pixels by z
334. ible Index fruChassisIndex frulndex Field Replaceable Unit Group 501 FRU Chassis Index Name fruChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 1 Description Defines the index one based of the chassis containing the FRU Syntax DellObjectRange Access Read only FRU Index Name fruIndex Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 2 Description Defines the index one based of the FRU Syntax DellObjectRange Access Read only FRU Information Status Name fruInformationStatus Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 3 Description Defines the status of the FRU table entry Syntax DellStatus Access Read only FRU Information State Name fruInformationState Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 4 Description Defines the state of the FRU information Some information for the FRU may not be available if the state is other than ok 1 Syntax DellFRUInformationState Access Read only 502 Field Replaceable Unit Group FRU Device Name Name fruDeviceName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 5 Description Defines the device name of the FRU Syntax DisplayString SIZE 0 64 Access Read only FRU Manufacturer Name Name fruManufacturerName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1 6 Description Defines the manufacturer of the FRU Syntax DisplayString SIZE 0 64 Access Read only FRU Serial Number Name Name fruSerialNumberName Object ID 1 3 6 1 4 1 674 10892 1 2000 10 1
335. iceStatus 1 3 6 1 4 1 674 10892 1 700 12 1 5 Defines the status of the cooling device DellStatusProbe Read only ThermalGroup 185 Cooling Device Reading Name Object ID Description Syntax Access coolingDeviceReading 1 3 6 1 4 1 674 10892 1 700 12 1 6 Defines either the cooling device s speed in revolutions per minute RPM or the off on value of the fan When the value for coolingDeviceSubType is other than coolingDeviceSubTypelsDiscrete the value returned for this attribute is the speed in RPM or the OFF ON value of the cooling device When the value for coolingDeviceSubType is coolingDeviceSubTypelsDiscrete a value is not returned for this attribute DellSigned32BitRange Read only Cooling Device Type Name Object ID Description Syntax Access coolingDeviceType 1 3 6 1 4 1 674 10892 1 700 12 1 7 Defines the cooling device type DellCoolingDevice Type See Table 9 1 Read only Cooling Device Location Name Name Object ID Description Syntax Access 186 coolingDeviceLocationName 1 3 6 1 4 1 674 10892 1 700 12 1 8 Defines the location of the cooling device in this chassis DellString Read only Thermal Group Cooling Device Upper Nonrecoverable Threshold Name coolingDeviceUppernonrecoverableThreshold Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 9 Description Defines the value of the fan s upper nonrecoverable threshold Syntax DellSigned32BitRange Access Read only Coolin
336. iceTypelIsAGlidePoint 6 deviceTypelIsATouchPad 7 Device type is not one of the following Device type is unknown Device type is a mouse Device type is a track ball Device type is a track point Device type is a glide point Device type is a touch pad Table 13 2 Processor Device Status State Variable Name De 1 1 ProcessorDeviceStatusState Data Type Integer Possible Data Values Meaning of Data Value other 1 unknown 2 enabled 3 userDisabled 4 biosDisabled 5 idle 6 Processor device type is not one of the following Device type is unknown Device is enabled Device is disabled by the user Device has its BIOS disabled Device is idle 292 Device Group Table 13 3 Processor Device Status Reading Variable Name De11ProcessorDeviceStatusReading Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value internalError 1 The processor experienced an internal error thermalTrip 2 The processor experienced a thermal trip configurationError 32 The processor experienced a configuration error processorPresent 128 The processor is present processorDisabled 256 The processor is disabled terminatorPresent 512 The terminator is Present processorThrottled 1024 The processor is throttled Table 13 4 Processor Device Type Variable Name De11ProcessorDeviceType
337. ices in this chassis The first byte returned represents the status of the first intrusion detection device the second byte returned represents the status of the second intrusion detection device and so on OCTET STRING SIZE 1 128 Read only System State Group 55 System State AC Power Switch State Details Name systemStateACPowerSwitchStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 32 Description Defines the individual state of all AC power switches in this chassis The first byte returned represents the state of the first AC power switch the second byte returned represents the state of the second AC power switch and so on Syntax OCTET STRING SIZE 1 128 Access Read only System State AC Power Switch Status Redundancy Name systemStateACPowerSwitchStatusRedundancy Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 33 Description Defines the overall redundancy status of the AC power switches in this chassis Syntax DellStatusRedundancy Access Read only System State AC Power Switch Status Details Name systemStateACPowerSwitchStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 34 Description Defines the individual status of all AC power switches in this chassis The first byte returned represents the status of the first AC power switch the second byte returned represents the status of the second AC power switch and so on Syntax OCTET STRING SIZE 1 128 Access Read only 56 System State Gro
338. ideo memory installed for the video adapter VGA feature connector On some systems with a built in VGA video adapter a VGA feature connector allows you to add an enhancement adapter such as a video accelerator to your computer A VGA feature connector can also be called a VGA pass through connector 722 Glossary video adapter The logical circuitry that provides in combination with the monitor your computer s video capabilities A video adapter may support more or fewer features than a specific monitor offers Typically a video adapter comes with video drivers for displaying popular application programs and operating systems in a variety of video modes On some Dell computers a video adapter is integrated into the system board Also available are many video adapter cards that plug into an expansion card connector Video adapters often include memory separate from RAM on the system board The amount of video memory along with the adapter s video drivers may affect the number of colors that can be simultaneously displayed Video adapters can also include their own coprocessor for faster graphics rendering video driver A program that allows graphics mode application programs and operating systems to display at a chosen resolution with the desired number of colors A software package may include some generic video drivers Any additional video drivers may need to match the video adapter installed in the computer video
339. ies Name Object ID Description Syntax Access systemB1IOSStateCapabilities 1 3 6 1 4 1 674 10892 1 300 50 1 3 Defines the capabilities of the system BIOS of this object DellStateCapabilities Read only System BIOS State Settings Name systemBlOSStateSettings Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 4 Description Defines the state of the system BIOS of this object Syntax DellStateSettings Access Read write System BIOS Status Name systemBIOSStatus Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 5 Description Defines the status of the system BIOS of this object Syntax DellStatus Access Read only System BIOS Size Name systemBIOSSize Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 6 Description Defines the image size of the system BIOS in kilobytes KB A zero 0 indicates that the image size of the BIOS is unknown Syntax DellUnsigned32BitRange Access Read only Chassis Information Group 85 System BIOS Release Date Name Name systemBIOSReleaseDateName Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 7 Description Defines the release date of the system BIOS Syntax DellDateName Access Read only System BIOS Version Name Name systemBlOSVersionName Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 8 Description Defines the version name of the system BIOS Syntax DellString Access Read only System BIOS Starting Address Name systemBlOSStartingAddress Object ID 1 3 6 1 4 1 674 10892 1 300 50 1 9 Description
340. ies and their current and voltage probes 9 Thermal Group defines variables for temperature 700 probes and cooling devices 10 User Security Group defines variables for creating and 800 modifying user accounts 11 Remote Flash BIOS Group defines variables for 900 updating the system s BIOS remotely 12 Port Group defines variables for major port types suchas 1000 keyboard monitor small computer system interface SCSI Universal Serial Bus USB and parallel and serial ports 13 Device Group defines variables for pointing 1100 keyboard processor cache memory and personal computer interface devices 14 Slot Group defines variables for the system s slots 1200 15 Memory Group defines variables for the system s 1300 physical memory 16 BIOS Setup Control Group defines variables for BIOS 1400 functions such as boot sequence speakers Wake on the local area network LAN diskettes ports and network interface controllers NIC Introduction Table 1 2 Server Administrator Instrumentation MIB Sections in This Guide continued Section Topics MIB Group Numbers 17 Local Response Agent Group defines variables for 1500 global settings and actions These variables allow users to predetermine how the system responds to a particular type of event 18 Cost of Ownership Group defines variables for tracking 1600 data on the system s service contract lease repair records trouble ti
341. ilities 1 3 6 1 4 1 674 10892 1 1300 10 1 3 Defines the capabilities of the physical memory array DellStateCapabilities Read only Physical Memory Array State Settings Name Object ID Description Syntax Access physicalMemoryArrayStateSettings 1 3 6 1 4 1 674 10892 1 1300 10 1 4 Defines the state of the physical memory array DellStateSettings read write Physical Memory Array Status Name Object ID Description Syntax Access physicalMemoryArrayStatus 1 3 6 1 4 1 674 10892 1 1300 10 1 5 Defines the status of the physical memory array DellStatus Read only Physical Memory Array Use Name Object ID Description Syntax Access physicalMemoryArrayUse 1 3 6 1 4 1 674 10892 1 1300 10 1 6 Defines the use of the physical memory array DellPhysicalMemoryArrayUse See Table 15 2 Read only MemoryGroup__ 327 Physical Memory Array Error Checking and Correcting ECC Type Name physicalMemoryArrayECCType Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 7 Description Defines the ECC type used by the physical memory array Syntax DellPhysicalMemoryArrayECCType See Table 15 2 Access Read only Physical Memory Array Location Name physicalMemoryArrayLocation Object ID 1 3 6 1 4 1 674 10892 1 1300 10 1 8 Description Defines the location of the physical memory array Syntax DellPhysicalMemoryArrayLocation See Table 15 1 Access Read only Physical Memory Array Maximum Size Name physicalMemoryArrayM
342. ilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 IDE control capabilities are unknown ideControlAutoConfigOr Capable 2 Enable IDE controller is autoconfigurable or enable capable Table 16 18 Diskette Control Settings Variable Name De11DisketteControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Diskette control state is unknown disketteControlAutoConfigEnabled Diskette control is set as OrEnabled 2 autoconfigurable or enabled Table 16 19 Network Interface Control Capabilities Variable Name DellNetworkInterfaceControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Unknown setup BIOS network interface capabilities enableCapable 2 Setup BIOS is capable of enabling the network interface enableWithout PXECapable 4 Setup BIOS is capable of enabling the NIF without Pre boot eXecution Environment PXE BIOS Setup Control Group 383 384 Table 16 20 Network Interface Control Settings Variable Name De1 1NetworkInterfaceControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Network interface state is unknown enabled 2 Network interface is enabled enabledWithout Px ie HS Network interface is enabled without PXE BIOS Setup Control Group Local Response Ag
343. inable asset tag for the enclosure Syntax DisplayString Access Read only Enclosure Asset Name Name enclosureAssetName Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 10 Description Customer definable asset name of the enclosure Syntax DisplayString Access Read only Enclosure Split Bus Part Number Name enclosureSplitBusPartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 11 Description Identifies the enclosure s split bus part number Syntax DisplayString Access Read only Enclosure Product ID Name enclosureProductID Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 12 Description Identifies the enclosure s product identification This also corresponds to the enclosure type Syntax DisplayString Access Read only 542 Storage Management Group Enclosure Kernel Version Name enclosureKernelVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 13 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only Enclosure ESM1 Part Number Name enclosureESM1PartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 14 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only Enclosure ESM2 Part Number Name enclosureESM2PartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 15 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only Storage Management Group 543 Enclosure Type Name enclosureT
344. index one based of the base board Syntax DellObjectRange Access Read only Baseboard State Capabilities Name baseBoardStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 3 Description Defines the state capabilities of the baseboard Syntax DellStateCapabilities Access Read only 96 Chassis Information Group Baseboard State Settings Name Object ID Description Syntax Access baseBoardStateSettings 1 3 6 1 4 1 674 10892 1 300 80 1 4 Defines the state settings of the baseboard DellStateSettings Read write Baseboard Status Name Object ID Description Syntax Access baseBoardStatus 1 3 6 1 4 1 674 10892 1 300 80 1 5 Defines the status of the baseboard DellStatus Read only Baseboard Feature Flags Name Object ID Description baseBoardFeatureFlags 1 3 6 1 4 1 674 10892 1 300 80 1 6 Defines the features of the baseboard Syntax DellBaseBoardFeatureFlags Access Read only Baseboard Type Name baseBoardType Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 7 Description Syntax Access Defines the type of the baseboard DellBaseBoard Type Read only Chassis Information Group 97 Baseboard Type Name Name baseBoardTypeName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 8 Description Defines the name of the type of baseboard Syntax DellString Access Read only Baseboard Location Name Name baseBoardLocationName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 9 Description Define
345. ing alerts and log events when certain parameters exceed their preset thresholds All of the traps documented in this section belong to the MIB enterprise identified by OID 1 3 6 1 4 1 3183 1 1 1 Table 25 19 BMC Traps TrapID Description Severity 262402 Generic Critical Fan Failure Critical 262530 Generic Critical Fan Failure Cleared Informational 131330 Under Voltage Problem Lower Critical Critical going low 131458 Under Voltage Problem Cleared Informational Traps 667 Table 25 19 BMC Traps continued TrapID Description Severity 131841 Generic Critical Voltage Problem Critical 131840 Generic Critical Voltage Problem Informational Cleared 65792 Under Temperature Warning Lower non Warning critical going low 65920 Under Temperature Warning Cleared Informational 65794 Under Temperature Problem Lower Critical Critical going low 65922 Under Temperature Problem Cleared Informational 65799 Over Temperature warning Upper non Minor critical going high 65927 Over Temperature warning Cleared Informational 65801 Over Temperature Problem Upper Critical Critical going high 65929 Over Temperature Problem Cleared Informational 131328 Under Voltage Warning Lower Non Warning Critical going low 131456 Under Voltage Warning Cleared Informational 131330 Under Voltage Problem Lower Critical Critical going low 131458 Under Voltage Problem Cleared Informational 13133
346. ing at objects displayed on the screen MPEG Acronym for Motion Picture Experts Group MPEG is a digital video file format ms Abbreviation for millisecond s MTBF Abbreviation for mean time between failures multifrequency monitor A monitor that supports several video standards A multifrequency monitor can adjust to the frequency range of the signal from a variety of video adapters Glossary 707 mV Abbreviation for millivolt s name The name of an object or variable is the exact string that identifies it in an SNMP Management Information Base MIB file or in a DMI Management Information Format MIF file or in a CIM Management Object File MOF NDIS Abbreviation for Network Driver Interface Specification NIC Acronym for network interface controller NIF Acronym for network interface function This term is equivalent to NIC NMI Abbreviation for nonmaskable interrupt A device sends an NMI to signal the microprocessor about hardware errors such as a parity error noninterlaced A technique for decreasing screen flicker by sequentially refreshing each horizontal line on the screen ns Abbreviation for nanosecond s one billionth of a second NTFS Abbreviation for the NT File System option in the Windows NT operating system NuBus Proprietary expansion bus used on Apple Macintosh personal computers NVRAM Acronym for nonvolatile random access memory Memory that does not lose its contents when
347. ion lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt Chassis intrusion state lt Intrusion state gt Chassis Intrusion Detected 1254 Chassis intrusion detected Error Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt Chassis intrusion state lt Intrusion state gt A chassis intrusion sensor in the specified system detected that a cover was opened while the system was operating but has since been replaced The sensor location chassis location previous state and chassis intrusion state are provided A chassis intrusion sensor in the specified system detected that the system cover was opened while the system was operating The sensor location chassis location previous state and chassis intrusion state are provided Traps 647 Redundancy Unit Traps Redundancy means that a system chassis has more than one of certain critical components Fans and power supplies for example are so important for preventing damage or disruption of a computer system that a chassis may have extra fans or power supplies installed Redundancy allows a second or nth fan to keep the chassis components at a safe temperature when the primary fan has failed Redundancy is normal when the intended number of critical components are operating Redundancy is degraded when a component fails but other
348. ionCodeIsNoExternalPower 10 An external power adapter must be connected complet ionCodeIsNo12VoltSet 11 12 volts V could not be set completionCodeIsNo12VoltRemoval 12 12 V could not be removed completionCodeIsFlashMemoryFailed A flash memory failure occurred 13 completionCodeIsGeneralFailure 14 A general failure occurred complet ionCodeIsDataMiscompare 15 A data miscompare error occurred complet ionCodeIsNoImageFound 16 The flash BIOS image could not be found in memory completionCodeIsNoUpdatePerformed No update operation has been 17 performed Remote Flash BIOS Group 207 208 Remote Flash BIOS Group Port Group The Port Group provides information about the different types of ports that may be present in your system This management information base MIB group also provides information about the capabilities states and settings that are possible for each port Port Group Tables The following MIB tables define objects in the Port Group Pointing Port Table Keyboard Port Table Processor Port Table Memory Device Port Table Monitor Port Table Small Computer System Interface SCSI Port Table Parallel Port Table Serial Port Table Universal Serial Bus USB Port Table Pointing Port Table Name pointingPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 10 Description Defines the Pointing Port Table Syntax IntegerPointingPort TableEntry Access Not accessible Port Group 209
349. iption Defines the option information description name Syntax DellCostofOwnershipString Access Read write COO Maintenance Table Name cooMaintenanceTable Object ID 1 3 6 1 4 1 674 10892 1 1600 80 Description Defines the COO Maintenance Table Syntax SEQUENCE OF CooMaintenanceTableEntry Access Not accessible COO Maintenance Table Entry Name cooMaintenanceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 80 1 Description Defines the COO Maintenance Table entry Syntax CooMaintenanceTableEntry Access Not accessible Index cooMaintenancechassisIndex cooMaintenancelndex 416 Cost of Ownership Group COO Maintenance Chassis Index Name Object ID Description Syntax Access cooMaintenancechassisIndex 1 3 6 1 4 1 674 10892 1 1600 80 1 1 Defines the index one based of this chassis DellObjectRange Read only COO Maintenance Index Name Object ID Description Syntax Access cooMaint enance Index 1 3 6 1 4 1 674 10892 1 1600 80 1 2 Defines the index of this system s maintenance information DellObjectRange Read only COO Maintenance State Name Object ID Description Syntax Access cooMaintenanceState 1 3 6 1 4 1 674 10892 1 1600 80 1 3 Defines the state of this system s maintenance information DellStateSettings Read only COO Maintenance Start Date Name Name Object ID Description Syntax Access cooMaintenanceStartDateName 1 3 6 1 4 1 674 10892 1 1600 80 1 4 Defines the start da
350. is Syntax DellStatus Access Read only 46 System State Group System State Power Unit State Details Name Object ID Description Syntax Access systemStatePowerUnitStateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 5 Defines the state of all power units in this chassis The results are returned as a binary octet string Each byte of the octet string represents the state of a specific power unit The first byte returned represents the state of the first power unit the second byte returned represents the state of the second power unit and so on The bytes have the same definition type as DellStateSettings OCTET STRING SIZE 1 128 Read only System State Power Unit Status Redundancy Name Object ID Description Syntax Access systemStatePowerUnitStatusRedundancy 1 3 6 1 4 1 674 10892 1 200 10 1 6 Defines the system status of the power unit s in this chassis DellStatus Read only System State Power Unit Status Details Name Object ID Description Syntax Access systemStatePowerUnitStatusDetails 1 3 6 1 4 1 674 10892 1 200 10 1 7 Defines the status of all power units in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific power unit The first byte returned represents the status of the first power unit the second byte returned represents the status of the second power unit and so on The bytes have the same definition t
351. is chassis if any A zero 0 means that this chassis is the parent of all other chassis managed by the Server Administrator DellObjectRange Read only chassisType 1 3 6 1 4 1 674 10892 1 300 10 1 6 Defines the chassis type DellChassisType See Table 5 2 Read only chassisName 1 3 6 1 4 1 674 10892 1 300 10 1 7 Defines the user assigned chassis name of the chassis DellString Read write Chassis Information Group 67 Chassis Manufacturer Name Name chassisManufacturerName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 8 Description Defines the manufacturer s name for this chassis Syntax DellString Access Read only Chassis Model Name Name chassisModelName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 9 Description Defines the system model type for this chassis Syntax DellString Access Read only Chassis Asset Tag Name Name chassisAssetTagName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 10 Description Defines the user assigned asset tag name for this chassis Syntax DisplayString SIZE 0 10 Access Read write Chassis Service Tag Name Name chassisServiceTagName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 11 Description Defines the service tag name for this chassis Syntax DisplayString SIZE 0 7 Access Read only 68 Chassis Information Group Chassis ID Name Object ID Description Syntax Access chassisID 1 3 6 1 4 1 674 10892 1 300 10 1 12 Defines the asset tag name for this cha
352. is not one of the following aught c ac ceo insertic replace pgrade device type is nknown pgrade device is on a er board pgrade device is in a zero om force ZIF socket Upgrade device is a ment There is no upgrade device insertic pgrad cuco pgrad ocket n pgrad pgrad pgrad pgrad pgrad Upgrade device is in a low n force LIF socket Upgrade device is a SLOT 1 processor e device is a SLOT 2 TOCCSSOT e device is a 370 pin e is by Slot A e is by Slot M Socket 423 Socket A e is by e is by Socket 462 Socket 478 Socket 754 e is by e is by l i l Upgrad l l l pgrad e is by Socket 940 Table 13 5 Processor Upgrade Information continued Variable Name De 11 ProcessorUpgradeInformation Data Type Integer Possible Data Values Meaning of Data Value processorUpgradeIsBySocket 939 18 Upgrade is by Socket 939 processorUpgradelIsBySocketmPGA604 19 Upgrade is by Socket mPGA604 processorUpgradeIsBySocketLGA771 20 Upgrade is by Socket LGA771 processorUpgradeIsBySocketLGA775 21 Upgrade is by Socket LGA775 Table 13 6 Processor Device Family Variable Name De1 1 ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsOther 1 deviceFamilyIsUnknown 2 deviceFamilyIs8086 3 deviceFamilyIs80286 4
353. is DB 9 connectorPortTypelIsAccessBusUSB 9 The keyboard port connector type is bus USB connectorPortTypeIsPC98 10 The keyboard port connector type is PC 98 238 Port Group Table 12 3 Processor Port Connector Types Variable Name De1 1 ProcessorPortConnectorType Data Type Integer Possible Data Value s Meaning of Data Value connectorPorti connectorPorti connectorPorti connectorPorti connectorPorti connectorPorti connectorPorti connectorPorti connectorPorti ypelIsOther 1 ypeIsUnknown 2 ypeIsZiIFSocket 4 ypelIsNone 6 ypeIsLIFSocket 7 ypeIsSlot1 8 TypeIsSlot2 9 connectorPorti TypeIs370PinSocket 10 ypeIsDaughterdBoard 3 ypeIlsAPiggyBackBoard 5 The processor port connector type is not one of the following The processor port connector type is unknown The processor port connector type is a daughter board The processor port connector type is a zero insertion force ZIF socket The processor port connector type is a replacement piggyback board There is no processor port connector processor is soldered in place The processor port connector type is a low insertion force LIF socket The processor port connector type is a slot one The processor port connector type is a slot two The processor port connector type is a 370 pin socket PortGroup 239 Table 12 4 Memory Device Port Connector Typ
354. is Index Name operatingSystemchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 1 Description Defines the index one based of the associated chassis Syntax DellObjectRange Access Read only Operating System State Capabilities Name operatingSystemStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 2 Description Defines the capabilities of the operating system Syntax DellStateCapabilities Access Read only Operating System State Settings Name operatingSystemStateSettings Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 3 Description Defines the state of the operating system Syntax DellStateSettings Access Read write Operating System Status Name operatingSystemStatus Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 4 Description Defines the status of the operating system Syntax DellStatus Access Read only 114 Operating System Group Operating System Is Primary Name operatingSystemIsPrimary Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 5 Description Specifies whether this operating system is the primary operating system Syntax DellBoolean Access Read only Operating System Name Name operatingSystemOperatingSystemName Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 6 Description Defines the name of the operating system running on the system Syntax DisplayString SIZE 0 255 Access Read only Operating System Version Name Name operatingSystemOperatingSystemVersionName Object ID 1 3 6 1 4 1 674 10892
355. is appendix contains definitions for data types that are standard in most contexts across the information technology industry These are the most common data types for describing variable values defined in the 10892 mib dcs3rmt mib and des3fru mib files Server Administrator specific variable values are defined in the last section of the section in which they are introduced Common Data Types Common data types include several types of strings the object range signed and unsigned bit ranges and the familiar Boolean true or false data type Table A 1 Common Data Types Variable Name Definition DellString DisplayString SIZE 0 64 DellSecurityString DisplayString SIZE 0 255 DellCostofOwnershipString DisplayString SIZE 0 64 DellObjectRange INTEGER 1 128 DellUnsigned8BitRange INTEGER 1 256 DellUnsigned16BitRange INTEGER 1 65535 DellSigned32BitRange INTEGER 2147483647 2147483647 DellBoolean INTEGER 0 1 FALSE 0 TRUE 1 DellUnsigned32BitRange INTEGER 1 2147483647 Standard Data Type Definitions 677 Variables with Data Types of State Capabilities and State Capabilities Unique Variables with definitions of lt variable name gt StateCapabilities or lt variable name gt StateCapabilitiesUnique are integers representing a series of bit definitions They are NOT enumerations and should be treated as bit fields The value is passed as a decimal value The de
356. is on The power supply is online and indicating that the AC power is on The power supply is online and indicating that it has a problem The power supply is online and OK Table 8 3 Power Supply Type Definitions Variable Name De1 1 PowerSupplyType Data Type Integer Possible Data Values Meaning of Data Value powerSupplyTypelIsOther 1 The power supply type is not one of the following powerSupplyTypelIsUnknown 2 The power supply type is unknown not known or not monitored powerSupplyTypelIsLinear 3 The power supply type is a linear power supply Power Group 171 Table 8 3 Power Supply Type Definitions continued Variable Name De11PowerSupplyType Data Type Integer Possible Data Values Meaning of Data Value powerSupplyTypeIsSwitching 4 The power supply type is a switching power supply powerSupplyTypelIsBattery 5 The power supply type is a battery powerSupplyTypelIsuUPsS 6 The power supply type is an uninterruptable power supply powerSupplyTypeIsConverter 7 The power supply type is a power converter power supply powerSupplyTypeIsRegulator 8 The power supply type is a regulator power supply powerSupplyTypelIsAc 9 The power supply type is an AC power supply powerSupplyTypelIsDC 10 The power supply type is a DC power supply powerSupplyTypeIsVRM 11 The power supply type is a voltage regulator module VRM power supply Table 8 4 Power
357. is shared Table 8 12 AC Power Switch Redundancy Mode Variable Name De 1 1ACPowerSwitchRedundancyMode Data Type Integer Possible Data Values Meaning of Data Value nonRedundant 1 The AC power switch is not expecting redundancy redundant 2 The AC power switch is expecting redundancy Table 8 13 AC Power Cord State Capabilities Variable Name De 1 1ACPowerCordStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The AC power cord s capabilities are unknown onlineCapable 2 The AC power cord can be disabled offline or enabled online notReadyCapable 4 The AC power cord s capabilities are not ready 178 Power Group Table 8 14 AC Power Cord State Settings Variable Name De1 1ACPowerCordStateSettings Data Type Integer Possible Data Values Meaning of Data Value unknown 1 he AC power cord s state is unknown online 2 The AC power cord s state is disabled offline 0 or enabled online 1 notReady 4 he AC power cord s state is not ready acPowerCordHasPower The AC power cord has power 8 acPowerCordIsActive The AC power cord is the active source of Source 16 AC power Table 8 15 Battery Reading Variable Name De1 1BatteryReading Data Type Integer NOTE These values are bit masks so combination values are possible Possible Data Values Meaning of Data Value
358. itches are known as DIP switches they are normally packaged in groups of two or more switches in a plastic case Two common DIP switches are used on system boards slide switches and rocker switches The names of the switches are based on how the settings on and off of the switches are changed syntax The rules that dictate how you must type a command or instruction so that the computer understands it A variable s syntax indicates its data type Glossary 717 system board As the main circuit board the system board usually contains most of your computer s integral components such as the following e Microprocessor e RAM e Controllers for standard peripheral devices such as the keyboard Various ROM chips Frequently used synonyms for system board are motherboard and logic board system configuration information Data stored in memory that tells a computer what hardware is installed and how the computer should be configured for operation system diskette System diskette is a synonym for bootable diskette system memory System memory is a synonym for RAM System Setup program A BIOS based program that allows you to configure your computer s hardware and customize the computer s operation by setting such features as password protection and energy management Some options in the System Setup program require that you reboot the computer or the computer may reboot automatically in order to make a hardware confi
359. ities unknownCapabilities 1 The remote access hardware host capabilities are unknown smtpEmailCapable 2 The remote access hardware supports sending e mail using SMTP tftpRemoteFloppyCapable 4 The remote access hardware supports remote floppy boot using a TFTP server tfitpRemoteFwUpdateCapable 8 The remote access hardware supports remote firmware update using a TFTP server 470 Remote Access Group Table 19 9 Remote Access Host Settings Variable Name Del 1RemoteAccessHostSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 unknown 1 smtpEmailEnabled 2 tfitpRemoteFloppyEnabled 4 tftpRemoteFwUpdateEnabled 8 The remote access hardware has no host settings The remote access hardware host settings are unknown The remote access hardware SMTP client is enabled for sending e mail The remote access hardware TF TP client is enabled for remote floppy boot The remote access hardware TF TP client is enabled for remote firmware update Table 19 10 Remote Access Out Of Band Simple Network Management Protocol SNMP Capabilities Variable Name Del 1RemoteAccessOutOfBandSNMPCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 unknownCapabilities 1 oobSNMPAgent Capable 2 oobSNMPTrapsCapable 4 T SNMP capabilities T capabilities are unk T S T S he remote ac
360. ject ID Description Syntax Access controllerNexusID 1 3 6 1 4 1 674 10893 1 20 130 1 1 39 Durable unique ID for this controller DisplayString Read only Controller Alarm State Name Object ID Description Syntax Access controllerAlarmState 1 3 6 1 4 1 674 10893 1 20 130 1 1 40 Indicates state or setting for the controller s alarm Possible values 1 Enabled 2 Disabled 3 Not Applicable Integer Read only Storage Management Group 529 Controller Driver Version Name controllerDriverVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 41 Description Indicates currently installed driver version of the controller Syntax DisplayString Access Read only Controller PCI Slot Name controllerPCISlot Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 42 Description Indicates the PCI slot number or embedded number for controllers on the motherboard Syntax DisplayString Access Read only Controller Cluster Mode Name controllerClusterMode Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 43 Description Identifies if the controller is in cluster mode Possible values 1 Enabled 2 Disabled 3 Active enabled and active 99 Not Applicable Syntax Integer Access Read only 530 Storage Management Group Controller Minimum Firmware Version Name controllerMinFWVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 44 Description The minimum firmware version for Storage Management to support the
361. ject ID 1 3 6 1 4 1 674 10892 1 1000 60 1 6 Description Syntax Access Defines the security settings of the SCSI port DellPortSecurityState Read only PortGroup 225 SCSI Port Connector Type Name sCSIPortConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 7 Description Defines the connector type of the SCSI port Syntax DellSCSIPortConnectorType See Table 12 6 Access Read only SCSI Port Name Name sCSIPortName Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 8 Description Defines the name of the SCSI port Syntax DellString Access Read only SCSI Port BIOS Connector Type Name sCSIPortBIOSConnectorType Object ID 1 3 6 1 4 1 674 10892 1 1000 60 1 9 Description Defines the BIOS connector type of the SCSI port Syntax DellGenericPortConnectorlype Access Read only Parallel Port Table Name parallelPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 70 Description Defines the Parallel Port Table Syntax IntegerParallelPort TableEntry Access Not accessible 226 Port Group Parallel Port Table Entry Name Object ID Description Syntax Access Index parallelPortTableEntry 1 3 6 1 4 1 674 10892 1 1000 70 1 Defines the Parallel Port Table entry ParallelPort TableEntry Not accessible parallelPortchassisIndex parallelPortIndex Parallel Port Chassis Index Name Object ID Description Syntax Access parallelPortchassisIndex 1 3 6 1 4 1 674 10892 1 1000 70 1 1 Defines the index one based of
362. l 2 Warning 3 Normal 4 Unknown Syntax Integer Access Read only Software Manufacturer Name softwareManufacturer Object ID 1 3 6 1 4 1 674 10893 1 20 3 Description Identifies the manufacturer of the Storage Management software Syntax DisplayString Access Read only Software Product Name softwareProduct Object ID 1 3 6 1 4 1 674 10893 1 20 4 Description Identifies product information for the Storage Management software Syntax DisplayString Access Read only 508 Storage Management Group Software Description Name softwareDescription Object ID 1 3 6 1 4 1 674 10893 1 20 5 Description Identifies the product description for the Storage Management software Syntax DisplayString Access Read only Storage Management Information Group The Storage Management Information MIB Group defines the properties that identify the Storage Management software SNMP agent Display Name Name displayName Object ID 1 3 6 1 4 1 674 10893 1 20 100 1 Description Identifies the name of this management software for display purposes Syntax DisplayString Access Read only Description Name description Object ID 1 3 6 1 4 1 674 10893 1 20 100 2 Description Provides a short description of this management software Syntax DisplayString Access Read only Storage Management Group 509 Agent Vendor Name agent Vendor Object ID 1 3 6 1 4 1 674 10893 1 20 100 3 Description Identifies the name of the management software manuf
363. l Table to which this array disk is connected Syntax Integer Access Read only Array Disk Channel Connection Controller Name Name arrayDiskChannelConnectionControllerName Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 6 Description Identifies the name of the controller as represented in Storage Management to which this array disk is connected Syntax DisplayString Access Read only Storage Management Group 565 Array Disk Channel Connection Controller Number Name Object ID Description Syntax Access Fan Table arrayDiskChannelConnectionControllerNumber 1 3 6 1 4 1 674 10893 1 20 130 6 1 7 Identifies the instance number in the controllerTable of the controller to which this array disk is connected Integer Read only This table describes available properties for each fan on the managed system The following object sets up the Fan Table Name Object ID Description Syntax Access Fan Entry Name Object ID Description Syntax Access Index fanTable 1 3 6 1 4 1 674 10893 1 20 130 7 Defines the fan table SEQUENCE OF FanEntry Not accessible fanEntry 1 3 6 1 4 1 674 10893 1 20 130 7 1 Defines the fan table entry FanEntry Not accessible fanNumber 566 Storage Management Group Fan Number Name Object ID Description Syntax Access Fan Name Name Object ID Description Syntax Access Fan Vendor Name Object ID Description Syntax Access fanNumber 1 3 6 1 4 1
364. l messages The SNMP master agent uses an extension protocol that shields the SNMP extension agent from the standard SNMP protocol messages The extension protocol also provides a way for SNMP extension agents to send SNMP event notifications called traps in SNMPv1 The SNMP master agent is also responsible for sending SNMP event notification protocol messages to SNMP management applications On supported operating systems the SNMP master agent is provided with the operating system For example on supported Microsoft Windows operating systems the Windows SNMP service is the SNMP master agent For information on the versions of the SNMP protocol supported by the SNMP master agent see the operating system documentation SNMP Extension Agent The SNMP extension agent is responsible for registering the MIB objects that it supports with the SNMP master agent and then processing requests from the SNMP master agent for those MIB objects The SNMP extension agent also initiates event notifications to the SNMP master agent The SNMP extension agent does not receive or send standard SNMP protocol messages The SNMP extension agent communicates with the SNMP master agent using an extension protocol defined by the SNMP master agent The Server Administrator SNMP subagent is an SNMP extension agent 24 Introduction Managed Object A managed object is any item in a computer system that can be singled out for discovery monitoring or user inte
365. lExceptOperating The operator can reboot and power off SystemShutdownCapable 7 capable host manualOperatingSystemShut The operator can shut down the downCapable 8 operating system shutdown capable host manualFullyCapable 15 The operator can reboot power on and off the power cycle capable host and shut down the operating system shutdown capable host Chassis Information Group 105 Table 5 12 Host Control Settings Variable Name De 1 1HostControls ettings NOTE An operator can manually cause these actions using SNMP Data Type Integer Possible Data Values Meaning of Data Value manualReboot 1 manual PowerOFF 2 manual PowerCycle 4 manualOperatingSystemShutdown 8 manualOperatingSystemShutdown ThenReboot 9 manualOperatingSystemShutdown ThenPowerOFF 10 manualOperatingSystemShutdown ThenPowerCycle 12 The operator can reboot the host The operator can power off the host Power cycle the host The operator can shut down t operating system on the host The operator can shut down t ne ne operating system on the host then reboot The operator can shut down t ne operating system on the host then power off machine The operator can shut down t ne operating system on the host then power cycle machine Table 5 13 Watchdog Control Capabilities Variable Name De1 LWat chDogControlCapabilities NOTE When the system determi
366. lInAuthMschapCapable 256 The dial up functionality can support MSCHAP authentication type for the dial in feature Table 19 23 Remote Dial Up State Settings Variable Name De1 1RemoteDialUpStateSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 unknown 1 enabled 2 notReadyCapable 4 dialInEnabled 8 dialOutEnabled 16 The dial up functionality has no state settings The dial up functionality state settings are unknown The dial up functionality is enabled The dial up functionality is in the not ready state The dial up functionality dial in feature is enabled The dial up functionality dial out feature is enabled Remote Access Group 477 Table 19 23 Remote Dial Up State Settings continued Variable Name De 1 1 Remot Data Type Integer eDialUpStateSettings Possible Data Values Meaning of Data Value dialInDHCPEnabled 32 dialInAuthAnyEnabled 64 dialInAuthEncrypted Enabled 128 dialInAuthMschapEnab led 256 The dial up functionality uses DHCP to obtain an IP address for the dial in feature The dial up functionality accepts any authentication type including clear text for the dial in feature The dial up functionality uses only encrypted passwords CHAP authentication type for the dial in feature The dial up functionality uses only MSCHAP authentication type for the dial in feature Table 19 24 Remo
367. lass 8 The chassis system class is storage Chassis Information Group 109 110 Table 5 21 Firmware Type Variable Name De11FirmwareType Data Type Integer Possible Data Values Meaning of Data Value other 1 unknown 2 systemBI0S 3 embeddedSystemManagementCont roller 4 powerSupplyParallelingBoard 5 systemBackPlane 6 powerVault2xXxSKernel 7 powerVault2XxXSApplication 8 frontPanel 9 baseboardManagementController 10 hotPlugPCI 11 sensorData 12 peripheralBay 13 secondaryBackPlane 14 secondaryBackPlaneESM3And4 15 l Chassis Information Group The firmware type is other than following values The firmware type is unknown The firmware type is System BIOS The firmware type is Embedded System Management Controller The firmware type is Power Supply Paralleling Board The firmware type is System Primary Backplane The firmware type is Dell PowerVault 2XXS Kernel The firmware type is PowerVault 2XXS Application The firmware type is Front Panel Controller The firmware type is Baseboard Management Controller The firmware type is Hot Plug Peripheral Component Interconnect PCI Controller The firmware type is Sensor Data Records The firmware type is Peripheral Bay Backplane The firmware type is Secondary Backplane for ESM 2 systems The firmware type is Secondary Backplane for ESM 3 and 4 systems Table 5 21 Firmwa
368. le 393 COO Service Contract Table 404 COO CostEventLogTable 406 COO Warranty Table 408 COO Lease Information Table 410 COO Schedule Number Table 413 COO Options Table 414 COO Maintenance Table 416 COO RepairTable 418 Contents COO Support Information Table 420 COO Trouble Ticket Table 422 Cost of Ownership Variable Values 424 19 Remote Access Group 427 DRAC4andDRAC5 427 Remote Access Table 427 DRAGIIN 205 a See r ate E a a 433 Remote Access Table 434 Remote User Administration Table 443 Remote SNMP Trap Table 451 Remote Dial Up Table 456 Remote User Dial In Configuration Table 460 Remote Dial Out Table 463 Remote Access Variable Values 466 20 Cluster Group eyes wees so eho aa ee 483 Cluster Group 0 4 483 Cluster Table naaa aaa 483 Cluster Group Variable Values 486 21 Baseboard Management Controller Group 487 Baseboard Management Controller GroupTables 487 Baseboard Management Controller Table 487 Baseboard Management Controller Serial Interface Table 491 Baseboard Management Controller LAN Interface Table
369. le values MIB group Sections 3 5 7 8 9 and 11 specific MIB variables contain links to the tables through 18 that define these values in the last section of the section in which these variables are used Systems management terms acronyms and Glossary commonly managed components referred to in this reference guide Server Administrator standard data types that Appendix A Standard Data specify variable values in this reference guide Type Definitions Introduction 23 SNMP Basic Terminology It is important to have a good understanding of the key technical terms used in this guide This guide provides definitions for all essential terms used in describing the Server Administrator MIBs The Glossary contains definitions for all essential terms and acronyms SNMP Master Agent Typically the SNMP agent on a managed system consists of one SNMP master agent and zero or more SNMP extension agents This SNMP agent extendable structure facilitates the addition of new MIB modules without having to rebuild the entire SNMP agent and is invisible to SNMP management applications The SNMP master agent is responsible for receiving SNMP request protocol messages from SNMP management applications and sending SNMP response protocol messages As part of processing SNMP request protocol messages the SNMP master agent typically communicates with one or more SNMP extension agents This communication does not involve standard SNMP protoco
370. lp administrators locate the problem chassis Table 5 10 Chassis Identification Control Settings Variable Name De11ChassisIdentifyControlSettings Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The chassis identification control s state is unknown enabled 2 The chassis identification control s state is disabled offline a binary 0 value or enabled online a binary 1 value notReady 4 The chassis identification control s state is not ready 104 Chassis Information Group Table 5 10 Chassis Identification Control Settings continued Variable Name De11ChassisIdentifyControlSettings Data Type Integer Possible Data Values Meaning of Data Value identifyChassis 8 The chassis identification control s LEDs may be returned to normal 0 or identify chassis 1 identifyChassisAndEnable The chassis identification control s 10 LEDs may be returned to normal a binary 0 value or identify chassis and enabled a binary value Table 5 11 Host Control Capabilities Variable Name Del LHostControlCapabilities NOTE An operator can manually cause these actions using SNMP Data Type Integer Possible Data Values Meaning of Data Value manualReboot Capable 1 The operator can reboot capable host manualPowerOFFCapable 2 The operator can power off capable host manualPowerCycleCapable 4 The operator can power cycle capable host manualAl
371. lt in NIC supports pattern matching Bit 52System BIOS supports a 7 character service tag Bit 53 63Reserved Syntax DellUnsigned64BitRange 88 Chassis Information Group System BIOS Characteristics Ext 1 Name Object ID Description Syntax Access systemBlIOSCharacteristicsExt1l 1 3 6 1 4 1 674 10892 1 300 50 1 13 Defines additional characteristics of the system basic input output system BIOS This attribute is a bit field where a bit has the meaning defined below when set to 1 one Bit Position Meaning if Set Bit OACPI supported Bit 1USB Legacy is supported Bit 2AGP is supported Bit 3120 boot is supported Bit 4LS 120 boot is supported Bit SATAPI ZIP Drive boot is supported Bit 61394 boot is supported Bit 7Smart Battery supported DellUnsigned8BitRange Read only System BIOS Characteristics Ext 2 Name Object ID Description Syntax Access systemBIOSCharacteristicsExt2 1 3 6 1 4 1 674 10892 1 300 50 1 14 Defines additional characteristics of the system BIOS This attribute is a bit field where a bit has the meaning defined below when set to 1 one Bit Position Meaning if Set Bit OBIOS Boot Specification supported Bit 1Function key initiated Network Service boot supported Bit 2 Targeted Content Distribution supported Bit 3 7Reserved DellUnsigned8BitRange Read only Chassis Information Group 89 Firmware Table Name firmwareTable Object ID 1 3 6 1 4 1 674 10892 1 300 60
372. m Slot Type Name Object ID Description Syntax Access systemSlotCurrentUsage 1 3 6 1 4 1 674 10892 1 1200 10 1 6 Defines the current usage of the system slot DellStatus Read only systemSlotType 1 3 6 1 4 1 674 10892 1 1200 10 1 7 Defines the type of the system slot DellSystemSlotType See Table 14 3 Read only System Slot External Slot Name Name Object ID Description Syntax Access systemSlotSlotExternalSlotName 1 3 6 1 4 1 674 10892 1 1200 10 1 8 Defines the external connector name of the system slot DellString Read only Slot Group 315 System Slot Length Name systemSlotLength Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 9 Description Defines the length of the system slot Syntax DellSystemSlotLength See Table 14 5 Access Read only System Slot Slot ID Name systemSlotSlotID Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 10 Description Defines the slot identification number of the system slot A zero 0 indicates that the slot is embedded on the motherboard Syntax DellUnsigned32BitRange Access Read only System Slot Category Name systemSlotCategory Object ID 1 3 6 1 4 1 674 10892 1 1200 10 1 11 Description Defines the system slot category Syntax DellUnsigned32BitRange Access Read only System Slot Hot Plug Bus Width Name Object ID Description Syntax Access 316 systemSlotHot PlugBusWidth 1 3 6 1 4 1 674 10892 1 1200 10 1 12 Defines the bus width of the hot plug
373. m slot power button pressed to signal a toggle of the power state The system slot provides a 5 V supply The system slot provides a 3 3 V supply The slot s opening is shared with another slot Slot Group 319 Table 14 2 System Slot State Settings continued Variable Name De1 1SystemSlotStateSettings Data Type Integer Possible Data Values Meaning of Data Value sys sys sys systemSlot 8192 sys supports PMI able 16770 supports PMI n 16804 temSlotSupportsCard16 1024 temSlotSupportsCardBus 2048 temSlotSupportsZoomVideo 4096 Support sModemRingResume temSlotSupportsPMESignal 16384 Fand3P3Vand5VandHot Plugg Fand3P3Vand5VhasAdapterOoO supports PMEand3P3Vand5VhasAdapter OnandisHot support sPM Pluggable 16806 Fand3P3VIsSharedand5Vhas AdapterOnandisHot Pluggable 17316 The system slot supports PC Card 16 The system slot supports CardBus The system slot supports zoom video The system slot supports modem ring resume The system slot supports power management enable PME signal The system slot supports power management enable The system slot supports power management event PME supplies 3 3 V and supplies 5 V The adapter is on The system slot supports PME supplies 3 3 V and supplies 5 V The adapter is on and the system slot is hot pluggable The system slot supports PME supplies 3 3 V supplies 5
374. mal Group Variable Values 195 10 User Security Group 199 User Security Group Table 199 User Security Table 199 11 Remote Flash BIOS Group 203 Remote Flash BIOS Group Table 203 Remote Flash BIOS Table 203 Remote Flash BIOS Variable Values 206 12 Port Gouin cs wks eaten teases 209 PortGroupTables 209 Pointing PortTable 209 Keyboard PortTable 212 Processor PortTable 215 Memory Device PortTable 218 Monitor PortTable 221 Small Computer System Interface SCSI Port Table rat v2 cord oY aes See a ores 224 Parallel Port Table 226 Serial Port Table 230 Universal Serial Bus USB Port Table 234 Port Group Variable Values 237 Contents 13 Device Group ec as 2biules GAR ea 243 Device Tables 2 243 Pointing Device Table 243 Keyboard Device Table 246 Processor Device Table 248 Processor Device Status Table 256 Cache Device Table 259 Memory Device Table 265 Memory Device Mapped Address Table 272 Generic Device Table 275 PCI DeviceTable 278 PCI Device Configuration Space Table 281 Network Device Table 284 Devi
375. mber Enclosure Management Module Connection Number Name Object ID Description Syntax Access enclosureManagementModuleConnectionNumber 1 3 6 1 4 1 674 10893 1 20 130 14 1 1 Identifies the instance number of the enclosure memory module connection entry Integer Read only Enclosure Management Module Connection EMM Name Name Object ID Description Syntax Access enclosureManagementModuleConnect ionEMMName 1 3 6 1 4 1 674 10893 1 20 130 14 1 2 Identifies the name of the enclosure memory module in this connection as represented in Storage Management DisplayString Read only 594 Storage Management Group Enclosure Management Module Connection EMM Number Name Object ID Description Syntax Access enclosureManagementModuleConnect ionEMMNumber 1 3 6 1 4 1 674 10893 1 20 130 14 1 3 Identifies the instance number in the enclosureManagementModule able of the enclosure memory module in this connection Integer Read only Enclosure Management Module Connection Enclosure Name Name Object ID Description Syntax Access enclosureManagementModuleConnect ionEnclosureName 1 3 6 1 4 1 674 10893 1 20 130 14 1 4 Identifies the name of the enclosure as represented in Storage Management to which this enclosure memory module belongs DisplayString Read only Enclosure Management Module Connection Enclosure Number Name Object ID Description Syntax Access enclosu
376. me De11PointingDeviceType Data Type Integer Possible Data Values Meaning of Data Value deviceTypelIsOther 1 deviceTypelIsUnknown 2 deviceTypelIsAMouse 3 deviceTypelIsATrackBall 4 deviceTypelIsATrackPoint 5 deviceTypelIsAGlidePoint 6 Device type is not one of the following Device type is unknown Device type is a mouse Device type is a track ball Device type is a track point Device type is a glide point deviceTypelIsATouchPad 7 302 Device Group Device type is a touch pad Table 13 12 Cache Device Associativity Variable Name De11CacheDeviceAssociativity Data Type Integer Possible Data Values Meaning of Data Value deviceAssociativityIsOther 1 Device associativity 1s not one of the following deviceAssociativityIsUnknown 2 Device associativity is unknown deviceAssociativityIsDirectMapped 3 Device is direct mapped deviceAssociativityIsTwoWaySetAsso Device is two way set ciative 4 associative deviceAssociativityIsFourWaySetAsso Device is four way set ciative 5 associative deviceAssociativityIsFullyAssociative Device is fully associative 6 deviceAssociativityIsEightWaySetAsso Device is eight way set ciative 7 associative deviceAssociativityIsSixteenWaySet Device is sixteen way set Associative 8 associative Table 13 13 Cache Device Location Variable Name De 1 1 CacheDeviceLocation Data Type Integer Possible Data
377. me Object ID Description Syntax Access fanRollUpStatus 1 3 6 1 4 1 674 10893 1 20 130 7 1 14 Severity of the fan state This is the combined status of the fan and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Fan Component Status Name Object ID Description Syntax Access fanComponentStatus 1 3 6 1 4 1 674 10893 1 20 130 7 1 15 The status of the fan itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Storage Management Group 572 Fan Nexus ID Name Object ID Description Syntax Access Fan Revision Name Object ID Description Syntax Access fanNexusID 1 3 6 1 4 1 674 10893 1 20 130 7 1 16 Durable unique ID for this fan DisplayString Read only fanRevision 1 3 6 1 4 1 674 10893 1 20 130 7 1 17 Indicates the revision number of the fan in the enclosure DisplayString Read only Fan Connection Table This table describes the connection between each fan on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table The following object sets up the Fan Connection Table Name Object ID Description Syntax Access fanConnectionTable fanConnection Table Defines the fa
378. me cooRepairIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 90 1 2 Description Defines the index one based of the repair information for this system Syntax DellObjectRange Access Read only COO Repair State Name cooRepairState Object ID 1 3 6 1 4 1 674 10892 1 1600 90 1 3 Description Defines the state of the repair information for this system Syntax DellStateSettings Access Read only Cost of Ownership Group 419 COO Repair Counter Name cooRepairCounter Object ID 1 3 6 1 4 1 674 10892 1 1600 90 1 4 Description Defines the number of repairs that this system has undergone Syntax DellCostofOwnershipString Access Read write COO Repair Vendor Name Name cooRepairVendorName Object ID 1 3 6 1 4 1 674 10892 1 1600 90 1 5 Description Defines the name of the vendor that repairs this system Syntax DellStateSettings Access Read only COO Support Information Table Name cooSupportInformationTable Object ID 1 3 6 1 4 1 674 10892 1 1600 100 Description Defines the COO Support Information Table Syntax SEQUENCE OF cooSupportInformationTableEntry Access Not accessible COO Support Information Table Entry Name cooSupportInformationTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 100 1 Description Defines the COO Support Information Table entry Syntax cooSupportInformationTableEntry Access Not accessible Index cooSupportInformationchassisIndex cooSupportInformationIndex 420 Cost of Ownership Group COO Sup
379. message uniquely describe the severity and cause of the event and provide other relevant information such as the location of the event and the monitored item s previous state Instrumentation Traps lists all Server Administrator Instrumentation trap IDs in numerical order and includes each trap ID s corresponding description severity level and cause Description text in brackets for example lt State gt describes the event specific information provided by Server Administrator RAC Traps lists RAC trap IDs in numerical order and includes each trap ID s corresponding description severity level and cause BMC Traps lists BMC trap IDs and includes each trap ID s corresponding description and severity level Traps 629 630 Trap Variables This section describes the variables that are sent to the management console to provide additional information about a trap or alert generated by some event on your system The trap variables presented here apply to all Instrumentation and RAC traps Trap variables are sent in the order listed and are reserved for use only in traps When a varbind is created for a trap variable a zero is appended to the object ID OID to create the OID for the varbind System Variable Name Object ID Description Syntax Table Index OID Variable Name Object ID Description Syntax Message Variable Name Object ID Description Syntax Traps alertSystem 1 3 6 1 4 1 674
380. mory unit The first byte returned represents the status of the first redundant memory unit and so on The bytes have the same definition type as DellStatus OCTET STRING SIZE 1 128 Read only System State Group 61 System State Processor Device Status Combined Name systemStateProcessorDeviceStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 50 Description Defines the combined status of all processor devices of this chassis Syntax DellStatus Access Read only System State Processor Device Status List Name systemStateProcessorDeviceStatusList Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 51 Description Lists the status of each processor device of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a processor device The first byte returned represents the status of the first processor device and so on The bytes have the same definition type as DellStatus Syntax OCTET STRING SIZE 1 128 Access Read only System State Battery Status Combined Name systemStateBatteryStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 52 Description Defines the combined status of all batteries of this chassis Syntax DellStatus Access Read only 62 System State Group System State Battery Status List Name Object ID Description Syntax Access systemStateBatteryStatusList 1 3 6 1 4 1 674 10892 1 200 10 1 53 Lists the status of ea
381. mperatureConnectionEntry Access Not accessible Index temperatureConnectionNumber 586 Storage Management Group Temperature Probe Connection Number Name Object ID Description Syntax Access temperatureConnect ionNumber 1 3 6 1 4 1 674 10893 1 20 130 12 1 1 Identifies the instance number of the temperature probe connection entry Integer Read only Temperature Probe Connection Temperature Probe Name Name Object ID Description Syntax Access temperatureConnectionTemperatureName 1 3 6 1 4 1 674 10893 1 20 130 12 1 2 Identifies the name of the temperature probe in this connection as represented in Storage Management DisplayString Read only Temperature Probe Connection Temperature Probe Number Name Object ID Description Syntax Access temperatureConnect ionTemperatureNumber 1 3 6 1 4 1 674 10893 1 20 130 12 1 3 Identifies the instance number in the temperatureTable of the temperature probe in this connection Integer Read only Temperature Probe Connection Enclosure Name Name Object ID Description Syntax Access temperatureConnectionEnclosureName 1 3 6 1 4 1 674 10893 1 20 130 12 1 4 Identifies the name of the enclosure as represented in Storage Management to which this temperature probe belongs DisplayString Read only Storage Management Group 587 Temperature Probe Connection Enclosure Number Name temperatureConnectionEnclosureNumber Object ID 1 3 6
382. n about different types of pointing keyboard processor cache memory and peripheral component interconnect PCI devices Variables in this group cover information about type settings configuration manufacturer address or location and if applicable the speed of the device Device Tables The following management information base MIB tables define objects in the Device Group Pointing Device Table Keyboard Device Table Processor Device Table Processor Device Status Table Cache Device Table Memory Device Table Memory Device Mapped Address Table Generic Device Table PCI Device Table PCI Device Configuration Space Table Network Device Table Pointing Device Table Name pointingDeviceTable Object ID 1 3 6 1 4 1 674 10892 1 1100 10 Description Defines the Pointing Device Table This group of objects references the Pointing Port Index See Section 12 Syntax SEQUENCE OF PointingDevice TableEntry Access Not accessible Device Group 243 Pointing Device Table Entry Name Object ID Description Syntax Access Index pointingDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 10 1 Defines the Pointing Device Table entry PointingDeviceTableEntry Not accessible pointing DevicechassisIndex pointingDeviceIndex Pointing Device Chassis Index Name Object ID Description Syntax Access pointingDevicechassisIndex 1 3 6 1 4 1 674 10892 1 1100 10 1 1 Defines the index one based of this chassis
383. n connection table SEQUENCE OF FanConnectionEntry Not accessible Storage Management Group Fan Connection Entry Name Object ID Description Syntax Access Index fanConnectionEntry 1 3 6 1 4 1 674 10893 1 20 130 8 1 Defines the fan connection table entry FanConnectionEntry Not accessible fanConnectionNumber Fan Connection Number Name Object ID Description Syntax Access fanConnect ionNumber 1 3 6 1 4 1 674 10893 1 20 130 8 1 1 Identifies the instance number of the fan connection entry Integer Read only Fan Connection Fan Name Name Object ID Description Syntax Access fanConnect ionFanName 1 3 6 1 4 1 674 10893 1 20 130 8 1 2 Identifies the name of the fan in this connection as represented in Storage Management DisplayString Read only Fan Connection Fan Number Name Object ID Description Syntax Access fanConnectionFanNumber 1 3 6 1 4 1 674 10893 1 20 130 8 1 3 Identifies the instance number of the fan in the fanTable in the connection Integer Read only Storage Management Group 573 Fan Connection Enclosure Name Name fanConnect ionEnclosureName Object ID 1 3 6 1 4 1 674 10893 1 20 130 8 1 4 Description Identifies the name of the enclosure as represented in Storage Management to which this fan belongs Syntax DisplayString Access Read only Fan Connection Enclosure Number Name fanConnectionEnclosureNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130
384. n expansion card that plugs into an expansion card connector on the computer s system board An adapter card adds some specialized function to the computer by providing an interface between the expansion bus and a peripheral device Examples of adapter cards include network cards sound cards and SCSI adapters ADB Abbreviation for assign database AGP Abbreviation for Advanced Graphics Port A high performance graphics interface becoming available for Pentium Pro systems ASCII Acronym for American Standard Code for Information Interchange A text file containing only characters from the ASCII character set usually created with a text editor such as Notepad in Microsoft Windows is called an ASCII file Glossary 689 ASIC Acronym for application specific integrated circuit ASPI Advanced SCSI programming interface ASR Abbreviation for automatic system recovery asset tag code An individual code assigned to a computer usually by a system administrator for security or tracking purposes attribute An attribute or property contains a specific piece of information related to a component Attributes can be combined to form groups If an attribute is defined as read write it may be defined by a management application autoexec bat file The autoexec bat file is executed when you boot your computer after executing any commands in the config sys file This start up file contains commands that define the characte
385. n values are possible no features 0 This baseboard has no feature flags boardIsHostingBoard 1 This baseboard is a hosting board boardRequiresDaughterBoard This baseboard requires at least one 2 daughter board or auxiliary card boardIsRemovable 4 This baseboard is removable boardIsReplaceable 8 This baseboard is replaceable boardIsHot Swappable 16 This baseboard is hot swappable l Chassis Information Group Operating System Group The Operating System Group provides status and identifying information about a system s operating system Identifying information includes the name version service pack and patch level of the installed operating system Operating System Group Table The following management information base MIB tables define the objects in the Operating System Group e Operating System Table e Operating System Memory Table Operating System Table The following object sets up the Operating System Table Name operatingSystemTable Object ID 1 3 6 1 4 1 674 10892 1 400 10 Description Defines the Operating System Table Syntax SEQUENCE OF OperatingSystemTableEntry Access Not accessible Operating System Table Entry Name operatingSystemTableEntry Object ID 1 3 6 1 4 1 674 10892 1 400 10 1 Description Defines the Operating System Table entry Syntax OperatingSystem TableEntry Access Not accessible Index operatingSystemchassisIndex Operating System Group 113 Operating System Chass
386. nal details for the events gt lt Additional power supply status information gt Battery sensor status lt status gt Traps Specifies the automatic server recovery action that was performed for example Action performed was Power cycle Specifies the user initiated host control action that was requested for example Action requested was Reboot shutdown OS first Specifies possible additional details about the specified device for example Additional details Memory device DIMM_1A Serial number 11111111 Memory device DIMM 1B Serial number 22222222 Specifies any additional power supply information pertaining to the event for example Power supply input AC is off Power supply POK power OK signal is not normal Power supply is turned off Specifies the status reported by the battery sensor for example Battery sensor status Predictive failure Table 25 1 Trap Description Reference continued Description Line Item Explanation Chassis intrusion state lt Intrusion state gt Chassis location lt Name of chassis gt Configuration error type lt type of configuration error gt Current sensor value in Amps lt Reading gt Date and time of action lt Date and time gt Device location lt Location in chassis gt Discrete current state lt State gt Discrete temperature state lt State gt Specifies the chassis intrusion state open or cl
387. name of the controller as represented in Storage Management to which this array disk is connected Syntax DisplayString Access Read only Array Disk Enclosure Connection Controller Number Name arrayDiskEnclosureConnectionControllerNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 5 1 7 Description Identifies the instance number in the controllerTable of the controller to which this array disk is connected Syntax Integer Access Read only Array Disk Channel Connection Table This table describes the connections between array disks their channel and their associated controller For each object in the table its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found K NOTE Only array disks that are NOT part of an enclosure will be listed in this table Backplanes are considered enclosures by Storage Management Storage Management Group 563 The following object sets up the Array Disk Channel Connection Table Name arrayDiskChannelConnectionTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 Description Defines the array disk channel connection table Syntax SEQUENCE OF ArrayDiskChannelConnectionEntry Access Not accessible Array Disk Channel Connection Entry Name arrayDiskChannelConnectionEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 Description Defines the array disk channel connection table entry Syntax ArrayDiskChan
388. nclosure FirmWare Version Name enclosureFirmwareVersion Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 26 Description The firmware version of the enclosure Syntax DisplayString Access Read only Storage Management Group 547 Enclosure SCSI Rate Name enclosureSCSIRate Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 27 Description Actual SCSI rate in the enclosure Syntax DisplayString Access Read only Enclosure Part Number Name enclosurePartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 28 Description The part number of the enclosure Syntax DisplayString Access Read only Enclosure Serial Number Name enclosureSerialNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 29 Description Serial number of the enclosure Syntax DisplayString Access Read only Enclosure SAS Address Name enclosureSASAddress Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 30 Description The specified SAS address if this is a SAS enclosure Syntax DisplayString Access Read only 548 Storage Management Group Array Disk Table This table describes available properties for each physical array disk on the managed system The following object sets up the Array Disk Table Name arrayDiskTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 Description Defines the array disk table Syntax SEQUENCE OF ArrayDiskEntry Access Not accessible Array Disk Entry Name arrayDiskEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 Description
389. ncluding both disks and the controller Integer Read only Storage Management Group 521 Controller Logical Device Count Name controllerLogicalDeviceCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 12 Description Identifies the number of virtual disks on the controller Syntax Integer Access Read only Controller Partner Status Name controllerPartnerStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 13 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only Controller Host Port Count Name controllerHostPortCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 14 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller Memory Size in Megabytes Name controllerMemorySizeInMB Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 15 Description Identifies the size of memory in megabytes on the controller If this size is 0 it is less than a megabyte This attribute is only supported on Adaptec controllers Syntax Integer Access Read only 522 Storage Management Group Controller Memory Size in Bytes Name Object ID Description Syntax Access controllerMemorySizeInBytes 1 3 6 1 4 1 674 10893 1 20 130 1 1 16 Identifies the size of memory on the controller that is less than a megabyte This combined with the controllerMemorySizeInMB will be the total size of the memory This attribute is
390. nd ComponentStatus for each device Syntax Integer Access Read only Controller Rebuild Rate in Percent Name controllerRebuildRateInPercent Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 7 Description Identifies the percent of the compute cycles dedicated to rebuilding failed array disks Syntax Integer Access Read only 520 Storage Management Group Controller Firmware Version Name Object ID Description Syntax Access controllerFWVersion 1 3 6 1 4 1 674 10893 1 20 130 1 1 8 Identifies the controller s current firmware version DisplayString Read only Controller Cache Size in Megabytes Name Object ID Description Syntax Access controllerCacheSizeInMB 1 3 6 1 4 1 674 10893 1 20 130 1 1 9 Identifies the controller s current amount of cache memory in megabytes If this size is 0 it is less than a megabyte Integer Read only Controller Cache Size in Bytes Name Object ID Description Syntax Access controllerCacheSizeInBytes 1 3 6 1 4 1 674 10893 1 20 130 1 1 10 Identifies the controller s current amount of cache memory that is less than a megabyte This combined with the controllerCacheSizeInMB will be the total amount of memory Integer Read only Controller Physical Device Count Name Object ID Description Syntax Access controllerPhysicalDeviceCount 1 3 6 1 4 1 674 10893 1 20 130 1 1 11 Identifies the number of physical devices on the controller channel i
391. nelConnectionEntry Access Not accessible Index arrayDiskEnclosureConnectionNumber Array Disk Channel Connection Number Name arrayDiskChannelConnect ionNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 1 Description Identifies the instance number of the array disk channel connection entry Syntax Integer Access Read only Array Disk Channel Connection Array Disk Name Name arrayDiskChannelConnectionArrayDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 2 Description Identifies the name of the array disk in this connection as represented in Storage Management Syntax DisplayString Access Read only 564 Storage Management Group Array Disk Channel Connection Array Disk Number Name arrayDiskChannelConnectionArrayDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 3 Description Identifies the instance number of the array disk in the arrayDiskTable in this connection Syntax Integer Access Read only Array Disk Channel Connection Channel Name Name arrayDiskChannelConnect ionChannelName Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 4 Description Identifies the name of the channel as represented in Storage Management to which is array disk is connected Syntax DisplayString Access Read only Array Disk Channel Connection Channel Number Name arrayDiskChannelConnect ionChannelNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 6 1 5 Description Identifies the instance number of the channel in the channe
392. nes that the operating system is not responding it will automatically perform the selected action without operator intervention Data Type Integer Possible Data Values Meaning of Data Value automaticRebootCapable 1 automat icPowerCycleCapable 2 automaticNotificationCapable 4 106 Chassis Information Group Watchdog controls can be set to reboot capable host Watchdog controls can be set to power cycleable capable host Watchdog controls can be set to notify capable host Table 5 13 Watchdog Control Capabilities continued Variable Name De1 LWat chDogControlCapabilities NOTE When the system determines that the operating system is not responding it will automatically perform the selected action without operator intervention Data Type Integer Possible Data Values Meaning of Data Value automaticWatchDogTimerCapable Watchdog controls can be set to 8 function automatically automaticPowerOffCapable 16 Watchdog controls can be set to automatically power off host automaticAllExceptNotification Watchdog controls can be set to Capable 27 automatically perform all functions except notification capable automaticFullyCapable 31 Watchdog controls can be set to automatically perform all functions Table 5 14 Watchdog Control Settings Variable Name Del 1WatchControlSettings NOTE The watchdog timer is the mechanism used by a chassis to determine if the operating sys
393. nes the index one based of this chassis Syntax DellObjectRange Access Read only BIOS Setup Control BSUC Pointing Device Control Capabilities Name bSUCpointingDeviceControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 2 Description Defines the capabilities of the pointing device Syntax DellStateCapabilities Access Read only BIOS Setup Control Pointing Device Control Settings Name bSUCpointingDeviceControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 3 Description Defines the state of the pointing device Syntax DellStateSettings Access Read write 350 BIOS Setup Control Group BIOS Setup Control Pointing Device Control Status Name bSUCpointingDeviceControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 4 Description Defines the status of the pointing device Syntax DellStatus Access Read only BIOS Setup Control Pointing Device Control Name Name bSUCpointingDeviceControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 5 Description Defines the setup BIOS name of the pointing device Syntax DellString Access Read only BIOS Setup Control Numeric Lock Control Capabilities Name bsuUCnumLockControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 6 Description Defines the capabilities of the numeric lock Syntax DellStateCapabilities Access Read only BIOS Setup Control Numeric Lock Control Settings Name bSUCnumLockControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 7 D
394. ng BIOS Application Version A10 The Application Group defines information about the applications discovered on the system during an inventory scan Identifying information includes the application type the application version and the application description 622 Change Management Group Application Group Table The following object sets up the Application Group Table Name applicationTable Object ID 1 3 6 1 4 1 674 10899 1 6 Description Defines a table of application information for the system Syntax SEQUENCE OF ApplicationEntry Access Not accessible Application Entry Name applicationEntry Object ID 1 3 6 1 4 1 674 10899 1 6 1 Description Defines an application entry Syntax ApplicationEntry Access Read only Application Index Name applicationIndex Object ID 1 3 6 1 4 1 674 10899 1 6 1 1 Description Defines the unique index for this application Syntax Unsigned 16BitRange Access Read only Application Device Index Name applicationDeviceIndex Object ID 1 3 6 1 4 1 674 10899 1 6 1 2 Description Defines a cross index to the device table for the application Syntax Unsigned 6BitRange Access Read only Change Management Group 623 Application Component Type Name applicationComponentType Object ID 1 3 6 1 4 1 674 10899 1 6 1 3 Description Identifies the type of application reported Syntax DisplayString Access Read only Application Version Name applicationVersion Object ID 1 3 6 1 4 1 67
395. not respond to query 310 Device Group Table 13 24 Network Device iSCSI Capability Flags Variable Name De1 1NetworkDeviceiSCSICapabilityFlags Data Type Integer NOTE These values are bit fields so combination values are possible Possible Data Values Meaning of Data Value none 0 Querying for iSCSI capability is not supported unknown 1 Querying for iSCSI capability is supported but query returned an error available 2 Device has iSCSI capability notAvailable 4 Device does not have iSCSI capability cannot BeDetermined 8 Querying for iSCSI capability is supported but an error prevented querying driverNotResponding 16 Querying for iSCSI capability is supported but driver did not respond to query Device Group 311 312 Device Group Slot Group The Slot Group provides information about the types of slots that your system supports This management information base MIB group also provides information about the voltages capabilities states and settings that are possible for these slots System Slot Group Table The System Slot Group defines objects in the System Slot MIB table System Slot Table The following object sets up the System Slot Table Name systemSlotTable Object ID 1 3 6 1 4 1 674 10892 1 1200 10 Description Defines the System Slot Table Syntax IntegerSystemStateTableEntry Access Not accessible System Slot Table Entry Name systemSlotTableEntry Object ID
396. nsigned32BitRange Read only Device Group Memory Device Mapped Address Interleave Depth Name memoryDeviceMappedAddressInterleaveDepth Object ID 1 3 6 1 4 1 674 10892 1 1100 60 1 9 Description Defines the maximum number of consecutive rows from the referenced memory device that are accessed in a single interleaved transfer in the memory device mapped address Syntax DellUnsigned32BitRange Access Read only Memory Device Mapped Address Starting Address Name memoryDeviceMappedAddressStartingAddress Object ID 1 3 6 1 4 1 674 10892 1 1100 60 1 10 Description Defines the physical starting address in KB of the memory device mapped address Syntax DellUnsigned64BitRange Access Read only Memory Device Mapped Address Ending Address Name memoryDeviceMappedAddressEndingAddress Object ID 1 3 6 1 4 1 674 10892 1 1100 60 1 11 Description Defines the physical ending address in KB of the memory device mapped address Syntax DellUnsigned64BitRange Access Read only Generic Device Table Name genericDeviceTable Object ID 1 3 6 1 4 1 674 10892 1 1100 70 Description Defines the Generic Device Table Syntax SEQUENCE OF GenericDeviceTableEntry Access Not accessible Device Group 275 Generic Device Table Entry Name Object ID Description Syntax Access Index genericDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 70 1 Defines the Generic Device Table entry GenericDevice TableEntry Not accessible genericDevice
397. nsigned32BitRange Read only LRA Global Settings Capabilities Unique Name Object ID Description Syntax Access 1RAGlobalSettingsCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1500 10 1 4 Defines the set of global capabilities that all local response agents may or may not allow to be set or reset DellLocalResponseAgentCapabilities Unique See Table 17 1 Read only LRA Global Thermal Shutdown Capabilities Unique Name Object ID Description Syntax Access 1RAGlobalThermalShutdownCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 1500 10 1 5 Defines the set of thermal shutdown capabilities that are supported by the LRA DellLRAThermalShutdownCapabilitiesUnique Read only LRA Global Thermal Shutdown State Settings Unique Name Object ID Description Syntax Access 1RAGlobalThermalShutdownStateSettingsUnique 1 3 6 1 4 1 674 10892 1 1500 10 1 6 Defines the set of thermal shutdown state and settings that the local response agent supports DellLRAThermalShutdownStateSettingsUnique Read write Local Response Agent Group 387 LRA Action Table The Del lLocalResponseAgent CapabilitiesUnique variable in the global action table defines the capabilities that are allowed for a particular system The LRA Action Table that follows selects which of the system s capabilities global actions are to be enabled Name 1RAActionTableTable Object ID 1 3 6 1 4 1 674 10892 1 1500 20 Description Defines the LRA A
398. nt to a management system The management system provides a user interface to view data from the managed systems The management system and managed systems communicate over a network typically through User Datagram Protocol Internet Protocol UDP IP 32 Introduction The management system and a managed system communicate by means of a common data schema SNMP MIB files define the structure type and values of the SNMP data While MIBs can be standardized or enterprise specific most operating systems supply SNMP agents for the standard MIB I and MIB II schemas MIB I defines a base set of standard management information for systems implementing the Internet Protocol IP suite MIB II defines characteristics of the system characteristics of network interfaces and characteristics of components of the IP on the system In addition to the standard MIBs many hardware vendors have defined MIBs that provide management data specific to their systems and peripheral devices Monitored data can be retrieved through SNMP using the Get command Typically this command requires the host name or IP address of the target machine as well as the OID of the data to retrieve Exact details are dependent on the operating system and the development tools being used to create the management application The Get command has a variant known as GetNext SNMP MIB OIDs Each data class within an MIB is defined by an OID OIDs are unique across all MIBs An OID
399. nteger Read only Storage Management Group 601 Battery Connection Table This table describes the connection between each controller battery on the managed system and its controller Each controller number in the table corresponds to that controller instance in the controller Table The following object sets up the Battery Connection Table Name batteryConnectionTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 16 Description Defines the battery connection table Syntax SEQUENCE OF BatteryConnectionEntry Access Not accessible Battery Connection Entry Name batteryConnectionEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 16 1 Description Defines the battery connection table entry Syntax BatteryConnectionEntry Access BatteryConnectionEntry Index BatteryConnectionNumber Battery Connection Number Name batteryConnectionNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 16 1 1 Description Identifies the instance number of the battery connection entry Syntax Integer Access Read only 602 Storage Management Group Battery Connection Battery Name Name Object ID Description Syntax Access batteryConnectionBatteryName 1 3 6 1 4 1 674 10893 1 20 130 16 1 2 Identifies the name of the battery in this connection as represented in Storage Management DisplayString Read only Battery Connection Battery Number Name Object ID Description Syntax Access batteryConnectionBatteryNumber 1 3 6 1 4
400. ntrolSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The admin user has no control settings unknown 1 The admin user control settings are unknown numericPagerTest 2 A numeric pager test will be performed for the admin user alphaPagerTest 4 An alphanumeric pager test will be performed for the admin user emailTest 8 An e mail test will be performed for the admin user Table 19 16 Remote User Admin Alpha Protocol Type Variable Name De 1 1Remot eUserAdminAlphaProtocolType Data Type Integer Possible Data Values Meaning of Data Value other 1 The remote user admin alpha protocol type is not one of the following unknown 2 The remote user admin alpha protocol type is unknown alpha7E0 3 The remote user admin alpha protocol type is 7E0 alpha8N1 4 The remote user admin alpha protocol type is 8N1 474 Remote Access Group Table 19 17 Remote User Admin Alpha Baud Type Variable Name De1 1Remot eUserAdminAlphaBaudType Data Type Integer Possible Data Values Meaning of Data Value other 1 The remote user alphanumeric baud rate is not one of the following unknown 2 The remote user alphanumeric baud rate is unknown alphaBaud300 3 The remote user alphanumeric baud rate is 300 alphaBaud1200 4 The remote user alphanumeric baud rate is 1200 Table 19 18 Remote SNMP Trap State Capabilities Variable Name De1 LRemoteSNMPTrapState
401. ntry Name ideControlTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1400 60 1 Description Defines the IDE Control Table entry Syntax IdeContro TableEntry Access Not accessible Index ideControlchassisIndex ideControlIndex 368 BIOS Setup Control Group IDE Control Chassis Index Name ideControlchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 60 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only IDE Control Index Name ideControlIndex Object ID 1 3 6 1 4 1 674 10892 1 1400 60 1 2 Description Defines the index one based of the IDE controller in this chassis Syntax DellObjectRange Access Read only IDE Control Capabilities Unique Name ideControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 60 1 3 Description Defines the capabilities of the IDE controller Syntax DellideControlCapabilitiesUnique See Table 16 17 Access Read only IDE Control Settings Unique Name ideControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 60 1 4 Description Defines the settings for the IDE controller Syntax DellideControlCapabilitiesUnique See Table 16 17 Access Read only BIOS Setup Control Group 369 IDE Control Status Name ideControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 60 1 5 Description Defines the status for the IDE controller Syntax DellStatus Access Read only IDE Control Name Name ideControlName Object ID 1 3 6 1 4 1 674 108
402. oard Management Controller Group Tables The objects in the BMC group define information about the BMC and the serial and LAN interfaces that can be used to access the BMC remotely to perform management activities Objects for the serial interface define the serial connection mode flow control type and bit rate Objects for the LAN interface define the media access control MAC address internet protocol IP address subnet mask and default gateway The following MIB tables define the BMC group e Baseboard Management Controller Table e Baseboard Management Controller Serial Interface Table e Baseboard Management Controller LAN Interface Table Baseboard Management Controller Table Name bmcTable Object ID 1 3 6 1 4 1 674 10892 1 1900 10 Description Defines the Baseboard Management Controller Table Syntax SEQUENCE OF BmcTableEntry Access Not accessible Baseboard Management Controller Group 487 BMC Table Entry Name bmcTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 Description Defines the Baseboard Management Controller BMC Table Entry Syntax BmcTableEntry Access Not accessible Index bmcChassisIndex bmcIndex BMC Chassis Index Name bmcChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 1 Description Defines the index one based of the associated chassis Syntax DellObjectRange Access Read only BMC Index Name bmcIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 10 1 2 Description Defines the index one
403. obe s upper noncritical threshold DellSigned32BitRange Read write Voltage Probe Lower Noncritical Threshold Name Object ID Description Syntax Access voltageProbeLowerNonCriticalThreshold 1 3 6 1 4 1 674 10892 1 600 20 1 12 Defines the user assigned value of the voltage probe s lower noncritical threshold DellSigned32BitRange Read write Voltage Probe Lower Critical Threshold Name Object ID Description Syntax Access voltageProbeLowerCriticalThreshold 1 3 6 1 4 1 674 10892 1 600 20 1 13 Defines the value of the voltage probe s lower critical threshold DellSigned32BitRange Read only Voltage Probe Lower Nonrecoverable Threshold Name Object ID Description Syntax Access voltageProbeLowerNonRecoverableThreshold 1 3 6 1 4 1 674 10892 1 600 20 1 14 Defines the value of the voltage probe s lower nonrecoverable threshold DellSigned32BitRange Read only Power Group 151 Voltage Probe Probe Capabilities Name Object ID Description Syntax Access voltageProbeProbeCapabilities 1 3 6 1 4 1 674 10892 1 600 20 1 15 Defines the probe capabilities of the voltage probe DellProbeCapabilities Read only Voltage Probe Discrete Reading Name voltageProbeDiscreteReading Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 16 Description Defines the reading for a voltage probe of type voltageProbelypelsDiscrete When the value for voltageProbe lype is other than voltageProbelypels
404. obeTableEntry Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 Description Defines the Voltage Probe Table entry Syntax VoltageProbeTableEntry Access Not accessible Index voltageProbechassisIndex voltageProbeIndex Voltage Probe Chassis Index Name voltageProbechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Voltage Probe Index Name voltageProbeIndex Object ID 1 3 6 1 4 1 674 10892 1 600 20 1 2 Description Defines the index of voltage probes in this chassis Syntax DellObjectRange Access Read only 148 Power Group Voltage Probe State Capabilities Name Object ID Description Syntax Access voltageProbeStateCapabilities 1 3 6 1 4 1 674 10892 1 600 20 1 3 Defines the capabilities of the voltage probe DellStateCapabilities Read only Voltage Probe State Settings Name Object ID Description Syntax Access voltageProbeStateSettings 1 3 6 1 4 1 674 10892 1 600 20 1 4 Defines the state and settings of the voltage probe DellStateSettings Read write Voltage Probe Status Name Object ID Description Syntax Access voltageProbeStatus 1 3 6 1 4 1 674 10892 1 600 20 1 5 Defines the status of the voltage probe DellStatusProbe Read only Voltage Probe Reading Name Object ID Description Syntax Access voltageProbeReading 1 3 6 1 4 1 674 10892 1 600 20 1 6 Defines the value of
405. oduction o oo aaa aaa aaa 15 Audiences s heia eo ase Red heed 15 What s New inthisRelease 15 What s New in the Instrumentation MIB 15 What s New inthe Remote Access MIB 16 What s New in the Field Replaceable Unit MIB 16 What s New in the Storage Management Group MIB 16 What s New in the Change Management MIB 17 Introduction to the SNMP Reference Guide 17 GeneralContent 04 17 Server Administrator Instrumentation MIB 18 Server Administrator Remote AccessMIB 20 Server Administrator Baseboard Management Controller ASFMIB 21 Server Administrator Field Replaceable Unit MIB 21 Server Administrator Storage ManagementMIB 22 Server Administrator Change ManagementMIB 23 How This Guide Defines Technical Terms 23 SNMP Basic Terminology 24 Frequently Used Terms in Variable Names 27 TaDI S siaaa x We eae Be oh a ws A 27 Reference Guide Content Tables 29 Contents Section Organization Other Documents YouMayNeed Introduction to the Server Administrator SNMP Subagent SNMPMIBOIDs SNMP Security 22 Management Actions SNMP Traps o sened naa aaae ue 2 Instrumentation MIB Version Group 3 Sys MIB Major VersionNumber MIB Minor VersionNumber M
406. ointingDeviceNumberofButtons Object ID 1 3 6 1 4 1 674 10892 1 1100 10 1 8 Description Defines the number of buttons on the pointing device Syntax DellUnsigned8BitRange Access Read only Keyboard Device Table Name keyboardDeviceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 20 Description Defines the Keyboard Device Table This table references the Keyboard Port Index See Section 12 Syntax SEQUENCE OF KeyboardDevice TableEntry Access Not accessible Keyboard Device Table Entry Name keyboardDeviceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 Description Defines the Keyboard Device Table entry Syntax KeyboardDeviceTableEntry Access Not accessible Index keyboardDevicechassisIndex keyboardDeviceIndex Keyboard Device Chassis Index Name keyboardDevicechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only 246 Device Group Keyboard Device Index Name keyboardDeviceIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 2 Description Defines the index of the keyboard device for this chassis Syntax DellObjectRange Access Read only Keyboard Device State Capabilities Name keyboardDeviceStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1100 20 1 3 Description Defines the capabilities of the keyboard device Syntax DellStateCapabilities Access Read only Keyboard Device State Settings Name k
407. ol Capabilities continued Variable Name De11SerialPortControlCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value comlOrCom3CapableAndAuto Setup BIOS has enabled autoconfiguration of ConfigCapable 86 COM1 and COM3 serial ports com20rCom4CapableAndAuto Setup BIOS has enabled autoconfiguration of ConfigCapable 106 COM2 and COM4 serial ports allcomCapable 126 Setup BIOS is capable of enabling or autoconfiguring all serial ports Table 16 16 Serial Port Control Settings Variable Name De11SerialPortControlSettingsUnique Data Type Integer Possible Data Values Meaning of Data Value unknown 1 Serial port state is unknown enabled 2 Setup BIOS has enabled the serial port com 4 Setup BIOS has selected serial port 1 comlEnabled 6 Setup BIOS has enabled serial port 1 com2 8 Setup BIOS has selected serial port 2 com2Enabled 10 Setup BIOS has enabled serial port 2 com3 16 Setup BIOS has selected serial port 3 com3Enabled 18 Setup BIOS has enabled serial port 3 com4 32 Setup BIOS has selected serial port 4 com4Enabled 34 Setup BIOS has enabled serial port 4 comPortsAutoConfig 64 Setup BIOS has selected autoconfiguration of serial ports enabledAndAutoConfig 66 Setup BIOS has enabled autoconfiguration of serial ports 382 BIOS Setup Control Group Table 16 17 IDE Control Capabilities Variable Name Del 1ideControlCapab
408. on Defines the system events filter mask for this remote access user Syntax DellUnsigned32BitRange Access Read write 446 Remote Access Group Remote User Admin Alert Filter DRS Capabilities Name Object ID Description Syntax Access remoteUserAdminAlertFilterDrsCapabilities 1 3 6 1 4 1 674 10892 1 1700 20 1 13 Defines the DRS events filter capabilities for this remote access user DellUnsigned32BitRange Read only Remote User Admin Alert Filter System Capabilities Name Object ID Description Syntax Access remoteUserAdminAlertFilterSysCapabilities 1 3 6 1 4 1 674 10892 1 1700 20 1 14 Defines the system events filter capabilities for this remote access user DellUnsigned32BitRange Read only Remote User Admin Pager Numeric Number Name Name Object ID Description Syntax Access remot eUserAdminPagerNumericNumberName 1 3 6 1 4 1 674 10892 1 1700 20 1 15 Defines the numeric pager number for this remote access user DisplayString SIZE 0 95 Read write Remote User Admin Pager Numeric Message Name Name Object ID Description Syntax Access remot eUserAdminPagerNumericMessageName 1 3 6 1 4 1 674 10892 1 1700 20 1 16 Defines the message to send to the numeric pager for this remote access user DisplayString SIZE 0 31 Read write Remote Access Group __ 447 Remote User Admin Pager Numeric Hang up Delay Name remot eUserAdminPagerNumericHangupDelay Object ID 1 3 6 1 4
409. on Identifies the current state of battery Possible values 0 Unknown 1 OK 2 Failed 6 Degraded 7 Reconditioning 9 High 10 Low 12 Charging 21 Missing 36 Learning Syntax Integer Access Read only Storage Management Group 597 Battery Roll Up Status Name batteryRollUpStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 5 Description Severity of the battery state This is the combined status of the battery and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Battery Component Status Name batteryComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 6 Description The status of the battery itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only 598 Storage Management Group Battery Charge Count Name batteryChargeCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 7 Description The number of charges that have been applied to the battery Syntax Integer Access Read only Battery Max Charge Count Name batteryMaxChargeCount Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 8 Description Syntax Access The maximum number of charges that can be applied to the battery Integer Read only Battery Nexus ID Name Object ID Description Syn
410. on This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller C1 Target Name controllerClTarget Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 29 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller C1 Channel Name controllerC1Channel Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 30 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only 526 Storage Management Group Controller C1 Operating System Controller Name controllerc1lOSController Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 31 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller Battery State C1 Name controllerClBatteryState Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 32 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller Node World Wide Name Name controllerNodewwN Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 33 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller CO Port 1 World Wide Name Name controllerC0OPort1WWN Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 34 Description
411. on to the Server Administrator SNMP Subagent is a more technical introduction to the management information base MIB that underlies Server Administrator services Audience This guide is intended for system administrators network administrators and anyone who wants to write SNMP MIB applications to monitor systems What s New in this Release This section lists changes to the Server Administrator MIBs in this release of Server Administrator What s New in the Instrumentation MIB e Added the values to the Del 1ProcessorDeviceFamily processor device family deviceFamilylsSAMDTurion64X2 Mobile 137 deviceFamilyIsQuadCoreAMDOpteron 138 deviceFamilylsThirdGenerationAMDOpteron 139 e Added the MIB object to the Power Supply table powerSupplyPowerMonitorCapable Introduction 15 Added the values to the Del lAmperageProbeType enumeration amperageProbelypelsPowerSupplyAmps 23 amperageProbeTypelsPowerSupply Watts 24 amperageProbeTypelsSystemAmps 25 amperageProbeTypelsSystem Watts 26 Added the Power Usage table to the Power Group Added the value to the De1 1 FirmwareType enumeration iDRAC 17 Added the MIB objects to the Baseboard Management Controller BMC table bmcType bmcModuleName Added the MIB objects to the BIOS Setup Control table bSUCtpmSecurityControlCapabilities bSUCtpmSecurityControlSetting bSUCtpmSecurityControlStatus bSUCtpmSecurityC
412. only supported on Adaptec controllers Integer Read only Controller Drive Channel Count Name Object ID Description Syntax Access controllerDriveChannel Count 1 3 6 1 4 1 674 10893 1 20 130 1 1 17 This entry is obsolete Fibre channel is not supported in Storage Management Integer Read only Controller Fault Tolerant Name Object ID Description Syntax Access controllerFaultTolerant 1 3 6 1 4 1 674 10893 1 20 130 1 1 18 This entry is obsolete Fibre channel is not supported in Storage Management Integer Read only Storage Management Group 523 Controller CO Port 0 World Wide Name Name controllerCOPort OWWN Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 19 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller CO Port 0 Name Name controllerCOPort0Name Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 20 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller CO Port 0 ID Name controllerCOPort0OID Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 21 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller CO Target Name controllercoTarget Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 22 Description This entry is obsolete Fibre channel i
413. ontrolName What s New in the Remote Access MIB No changes What s New in the Field Replaceable Unit MIB No changes What s New in the Storage Management Group MIB 16 Added the states under the virtual disk states Degraded Redundancy Resynching Paused Added the values for the virtual disk s RAID type RAID 6 8 RAID 60 24 Introduction What s New in the Change Management MIB No changes Introduction to the SNMP Reference Guide This reference guide provides a formatted version of the Server Administrator Instrumentation MIB filename 10892 mib the Server Administrator Remote Access MIB filename dcs3rmt mib the Server Administrator Field Replaceable Unit MIB filename des3fru mib the Server Administrator Storage Management MIB filename destorag mib and the Server Administrator Change Management MIB filename dellcm mib that are released with the current version of Dell OpenManage Server Administrator Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to define MIB objects Content in this reference guide is organized as documented in the following subsections General Content Table 1 1 describes the sections that provide general information about the MIBs documented in this guide Table 1 1 General Content Sections in This Guide Section Topics MIB Group Number 1 Introduction to SNMP basics and to the MIBs
414. ontroller BMC LAN Interface Table Entry Syntax BmcLANInterfaceTableEntry Access Not accessible Index bmcLANInterfaceChassisIndex bmcLANInterfaceBMCIndex bmcLANInterfaceIndex 494 Baseboard Management Controller Group BMC LAN Interface Chassis Index Name Object ID Description Syntax Access bmcLANInterfaceChassisIndex 1 3 6 1 4 1 674 10892 1 1900 30 1 1 Defines the index one based of the associated chassis DellObjectRange Read only BMC LAN Interface BMC Index Name bmcLANInterfaceBMCIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 2 Description Defines the index one based of the associated BMC Syntax DellObjectRange Access Read only BMC LAN Interface Index Name bmcLANInterfaceIndex Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 3 Description Defines the index one based of the BMC LAN interface Syntax DellObjectRange Access Read only BMC LAN Interface State Capabilities Name Object ID Description Syntax Access bmcLANInterfaceStateCapabilities 1 3 6 1 4 1 674 10892 1 1900 30 1 4 Defines the state capabilities of the BMC LAN interface DellStateCapabilities Read only Baseboard Management Controller Group 495 BMC LAN Interface State Settings Name bmcLANInterfaceStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 5 Description Defines the state settings of the BMC LAN interface Syntax DellStateSettings Access Read write BMC LAN Interface Status Name bmcLANInterfaceS
415. oolingUnit IndexReference 1 3 6 1 4 1 674 10892 1 700 12 1 15 Defines the index for the associated system cooling unit in this chassis DellObjectRange Read only Cooling Device Subtype Name Object ID Description Syntax Access 188 coolingDeviceSubType 1 3 6 1 4 1 674 10892 1 700 12 1 16 Defines the cooling device subtype DellCoolingDeviceSubType See Table 9 2 Read only Thermal Group Cooling Device Probe Capabilities Name Object ID Description Syntax Access coolingDeviceProbeCapabilities 1 3 6 1 4 1 674 10892 1 700 12 1 17 Defines the probe capabilities of the cooling device DellProbeCapabilities Read only Cooling Device Discrete Reading Name Object ID Description Syntax Access coolingDeviceDiscreteReading 1 3 6 1 4 1 674 10892 1 700 12 1 18 Defines the reading for a voltage probe of type coolingDeviceSubTypelsDiscrete When the value for coolingDeviceSubType is other than coolingDeviceSubTypelsDiscrete a value is not returned for this attribute When the value for coolingDeviceSubType is coolingDeviceSubTypelsDiscrete the value returned for this attribute is the discrete reading for the cooling device DellCoolingDeviceDiscreteReading See Table 9 3 Read only Temperature Probe Table Name Object ID Description Syntax Access temperatureProbeTable 1 3 6 1 4 1 674 10892 1 700 20 Defines the Temperature Probe Table TemperatureProbe TableEntry Not acce
416. or Version Number 37 0 Operating System Group 625 Memory Table 115 Operating System Table 113 Operating System Memory Table 115 P Physical Devices Group 516 Physical Memory Card Table 340 Pluggable Device Traps 658 Port Group Keyboard Port Table 212 Memory Device Port Table 218 Monitor Port Table 221 Parallel Port Table 226 Pointing Port Table 209 Processor Port Table 215 Serial Port Table 230 Small Computer System Interface Port Table 224 variable values 237 Power Group AC Power Cord Table 161 AC Power Switch Table 158 Amperage Probe Table 152 Battery Table 163 Power Supply Table 144 Power Unit Table 141 Power Usage Table 165 variable values 170 Voltage Probe Table 148 Power Group tables 141 Processor Device Status Traps 657 Processor sensor detected a failure value 658 Processor sensor detected a warning value 657 Processor sensor returned to a normal state 657 Index 729 Redundant Memory Unit Table 337 Remote Access Group Remote Access Table 434 Remote SNMP Trap Table 451 Remote User Administration Table 443 Remote User Dial In Configuration Table 60 Remote User Dial Out Table 463 Remote Flash BIOS Group variable values 206 S sample SNMP output 683 Slot Group System Slot Table 313 variable values 317 SNMP introduction to 32 SNMP MIB OIDs 33 SNMP security 35 SNMP traps 36 SNMP basic terminology
417. ort TableEntry Access Not accessible Serial Port Table Entry Name serialPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 Description Defines the Serial Port Table entry Syntax SerialPort TableEntry Access Not accessible Index serialPortchassisIndex serialPortIndex 230 Port Group Serial Port Chassis Index Name serialPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Serial Port Index Name serialPort Index Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 2 Description Defines the index of the serial ports in this chassis Syntax DellObjectRange Access Read only Serial Port State Capabilities Name serialPortStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 3 Description Defines the capabilities of the serial port Syntax DellStateCapabilities Access Read only Serial Port State Settings Name serialPortStateSettings Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 4 Description Defines the state and settings of the serial port Syntax DellStateSettings Access Read write PortGroup 231 Serial Port Status Name serialPortStatus Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 5 Description Defines the status of the serial port Syntax DellStatus Access Read only Serial Port Security State Name serialPortSecurityState Object ID 1 3 6 1 4 1 674 10892 1 1000 80 1 6 Description
418. ory module A small circuit board containing DRAM chips that connects to the system board MHz Abbreviation for megahertz MIB Acronym for management information base MIB is used to send detailed status commands from or to an SNMP managed device microprocessor The primary computational chip inside the computer that controls the interpretation and execution of arithmetic and logic functions Software written for one microprocessor must usually be revised to run on another microprocessor CPU is a synonym for microprocessor 706 Glossary MIDI Abbreviation for musical instrument digital interface MIF Acronym for management information format A MIF file contains information status and links to component instrumentation MIF files are installed into the MIF database by the DMI service layer The content of a MIF is defined by a DTMF working committee and is published in the form of a MIF definition document This document identifies the groups and attributes that are relevant to DMI manageable components mm Abbreviation for millimeter s modem A device that allows your computer to communicate with other computers over telephone lines MOF Acronym for managed object format which is an ASCII file that contains the formal definition of a CIM schema mouse A pointing device that controls the movement of the cursor on a screen Mouse aware software allows you to activate commands by clicking a mouse button while point
419. osed for example Chassis intrusion state Open Specifies the name of the chassis that generated the message for example Chassis location Main System Chassis Specifies the type of configuration error that occurred for example Configuration error type Revision mismatch Specifies the current sensor value in amps for example Current sensor value 7 853 Specifies the date and time that an automatic server recovery action was performed for example Date and time of action Fri May 30 23 55 44 2003 Specifies the location of the device in the specified chassis for example Device location Mem Card A Specifies the state of the current sensor for example Discrete current state Good Specifies the state of the temperature sensor for example Discrete temperature state Good Traps 633 634 Table 25 1 Trap Description Reference continued Description Line Item Explanation Discrete voltage state lt State gt Fan sensor value lt Reading gt Log type lt Log type gt Memory device bank location lt Bank name in chassis gt Memory device location lt Device name in chassis gt Number of devices required for full redundancy lt Number gt Possible memory module event cause lt list of causes gt Traps Specifies the state of the voltage sensor for example Discrete voltage state Good Specifies the fan speed in revolutions per minute RPMs
420. osition and an OFF position Glossary 695 directory Directories help keep related files organized on a disk in a hierarchical inverted tree structure Each disk has a root directory for example a c gt prompt normally indicates that you are at the root directory of hard drive C Additional directories that branch off of the root directory are called subdirectories Subdirectories may contain additional directories branching off of them display adapter See video adapter DMA Abbreviation for direct memory access A DMA channel allows certain types of data transfer between RAM and a device to bypass the microprocessor DMI Abbreviation for Desktop Management Interface DMI enables the management of your computer system s software and hardware DMI collects information about the system s components such as the operating system memory peripherals expansion cards and asset tag Information about the system s components is displayed as a MIF file or through the Dell Inspector program DMTF Abbreviation for Distributed Management Task Force a consortium of companies representing hardware and software providers of which Dell is a member dpi Abbreviation for dots per inch DPMS Abbreviation for Display Power Management Signaling A standard developed by the Video Electronics Standards Association VESA that defines the hardware signals sent by a video controller to activate power management states in a moni
421. ountChassis 23 sealedCasePC 24 multiSystemChassis 25 The chassis type is a subnotebook The chassis type is a spacesaver The chassis type is a lunch box The chassis type is the main system chassis The chassis type is an expansion chassis The chassis type is a subchassis The chassis type is a bus expansion chassis The chassis type is a peripheral chassis The chassis type is a disk RAID chassis The chassis type is a rack mounted chassis The chassis type is a sealed case chassis The chassis type is a multisystem chassis Table 5 3 Connection Status Variable Name De 1 1 ConnectionStatus Data Type Integer Possible Data Values Meaning of Data Value unknown 2 ok 3 failure 4 The status of the chassis connection is unknown The status of the chassis connection is OK The status of the chassis connection is failure Chassis Information Group 101 Table 5 4 Fan Control Capabilities Variable Name De1 1 FanControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The fan s capabilities are unknown lowSpeedCapable 2 The fan can be set to low speed highSpeedCapable 4 The fan can be set to high speed lowOrHighSpeedCapable 6 The fan can be set to low or high speed Table 5 5 Front Panel LED Control Capabilities Variable Name De 1 LLEDControlCapabilities Data Type Integer Possible Data Valu
422. oup Enclosure Management Module Nexus ID Name Object ID Description Syntax Access enclosureManagementModuleNexusID 1 3 6 1 4 1 674 10893 1 20 130 13 1 12 Durable unique ID for this EMM DisplayString Read only Enclosure Management Module Revision Name Object ID Description Syntax Access enclosureManagementModuleRevision 1 3 6 1 4 1 674 10893 1 20 130 13 1 13 Identifies the revision number of the enclosure management module DisplayString Read only Enclosure Management Module Connection Table This table describes the connection between each enclosure management module on the managed system and its enclosure Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table The following object sets up the Enclosure Management Module Connection Table Name Object ID Description Syntax Access enclosureManagementModuleConnectionTable 1 3 6 1 4 1 674 10893 1 20 130 14 Defines the enclosure memory module connection table SEQUENCE OF EnclosureManagementModuleConnectionEntry Not accessible Storage Management Group 593 Enclosure Management Module Connection Entry Name Object ID Description Syntax Access Index enclosureManagementModuleConnectionEntry 1 3 6 1 4 1 674 10893 1 20 130 14 1 Defines the enclosure memory module connection table entry EnclosureManagementModuleConnectionEntry Not accessible enclosureManagementModuleConnectionNu
423. oup See the relevant section for more information about the MIB objects defined in a MIB group Introduction 21 Table 1 4 Server Administrator Field Replaceable Unit MIB Sections in This Guide Section Topic MIB Group Numbers 22 Field Replaceable Unit Group provides information 2000 about field replaceable units that may be present in your system Server Administrator Storage Management MIB The Server Administrator Storage Management MIB filename destorag mib provides storage management data that allows you to monitor the health of storage resources with SNMP management applications Table 1 5 describes each Server Administrator Storage Management MIB group and lists the MIB group number assigned to the MIB group The Server Administrator Storage Management MIB groups are identified by the SNMP OID 1 3 6 1 4 1 674 lt MIB group number gt where lt MIB group number gt is the MIB group number assigned to the MIB group See the relevant section for more information about the MIB objects defined in a MIB group Table 1 5 Server Administrator Storage Management MIB Sections in This Guide Section Topics MIB Group Numbers 23 Storage Management Group consists of definitions for the 10893 following MIB groups e Storage Management Group e Storage Management Information Group e Global Data Group e Physical Devices Group e Logical Devices Group e Storage Management Event Group 26 Storage Management
424. oup includes only the Remote Access Table Remote Access Table The following MIB object sets up the Remote Access Table Name remoteAccessTable Object ID 1 3 6 1 4 1 674 10892 1 1700 10 Description Defines the Remote Access Table Syntax SEQUENCE OF RemoteAccessTableEntry Access Not accessible Remote Access Table Entry Name remoteAccessTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 Description Defines the Remote Access Table entry Syntax RemoteAccessTableEntry Access Not accessible Index remoteAccessChassisIndex remoteAccessAdapterIndex Remote Access Group 427 Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellObjectRange Access Read only Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 2 Description Defines the index one based of the remote access hardware Syntax DellObjectRange Access Read only Remote Access Type Name remoteAccessType Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 3 Description Defines the type of remote access hardware Syntax DellRemoteAccess Type See Table 19 1 Access Read only Remote Access State Capabilities Name remoteAccessStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 4 Description Defines the state capabilities of the remote ac
425. p 183 Cooling Device Table Name coolingDeviceTable Object ID 1 3 6 1 4 1 674 10892 1 700 12 Description Defines the Cooling Device Table Syntax CoolingDevice TableEntry Access Not accessible Cooling Device Table Entry Name coolingDeviceTableEntry Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 Description Defines the Cooling Device Table entry Syntax CoolingDeviceTableEntry Access Not accessible Index cooling DevicechassisIndex coolingDeviceIndex Cooling Device Chassis Index Name coolingDevicechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Cooling Device Index Name coolingDeviceIndex Object ID 1 3 6 1 4 1 674 10892 1 700 12 1 2 Description Defines the index of cooling devices in this chassis Syntax DellObjectRange Access Read only 184 Thermal Group Cooling Device State Capabilities Name Object ID Description Syntax Access coolingDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 700 12 1 3 Defines the capabilities of the cooling device DellStateCapabilities Read only Cooling Device State Settings Name Object ID Description Syntax Access coolingDeviceStateSettings 1 3 6 1 4 1 674 10892 1 700 12 1 4 Defines the state and settings of the cooling device DellStateSettings Read write Cooling Device Status Name Object ID Description Syntax Access coolingDev
426. pabilities Object ID 1 3 6 1 4 1 674 10892 1 600 50 1 3 Description Defines the state capabilities of the battery Syntax DellStateCapabilities Access Read only Battery State Settings Name batteryStateSettings Object ID 1 3 6 1 4 1 674 10892 1 600 50 1 4 Description Defines the state settings of the battery Syntax DellStateSettings Access Read write 164 Power Group Battery Status Name Object ID Description Syntax Access Battery Reading Name Object ID Description Syntax Access batteryStatus 1 3 6 1 4 1 674 10892 1 600 50 1 5 Defines the status of the battery DellStatus Read only batteryReading 1 3 6 1 4 1 674 10892 1 600 50 1 6 Defines the reading of the battery DellBatteryReading see Table 8 15 Read only Battery Location Name Name Object ID Description Syntax Access batteryLocationName 1 3 6 1 4 1 674 10892 1 600 50 1 7 Defines the location of the battery DellString Read only Power Usage Table Name Object ID Description Syntax Access powerUsageTable 1 3 6 1 4 1 674 10892 1 600 60 Defines the Power Usage Table SEQUENCE OF PowerUsageTableEntry Not accessible Power Group 165 Power Usage Table Entry Name Object ID Description Syntax Access Index powerUsageTableEntry 1 3 6 1 4 1 674 10892 1 600 60 1 Defines the Power Usage Table Entry PowerUsageTableEntry Not accessible powerUsageChassisIndex powerUsageIndex Power Usage Chassis Index Name
427. particular managed object does Syntax defines the data type in which the values of the variable must be expressed Most variables in this reference guide use standard data types such as string or boolean All data types that are unique to server administrator variables are defined at the end of the section in which they occur Standard data types are defined in Standard Data Type Definitions Access specifies whether persons with administrative privileges can read but not modify the value of a variable read only or can both read and modify the value of a variable read write 26 Introduction Frequently Used Terms in Variable Names The following terms are frequently used in the name of a MIB variable Capability refers to the actions an object can perform or to actions that can be taken by the object Hot pluggable is an example of a capability If a card is hot pluggable it can be replaced while a system is running Capability settings refer to the capabilities of the object that the user can select from and activate if desired Capability settings allow users of the server administrator to predetermine how an object will behave under specific conditions Settings are the conditions of a manageable object that determine what happens when a certain value is detected in a component For example a user can set the upper critical threshold of a temperature probe to 75 degrees Celsius If the probe reaches that temperature the setting c
428. pha Modem Connect Time out Name remot eUserAdminPagerAlphaModemConnectTimeout Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 22 Description Defines the modem connection time out for the alphanumeric pager for this remote access user Syntax DellUnsigned32BitRange Access Read write Remote User Admin Pager Alpha Pager ID Name Name remot eUserAdminPagerAlphaPagerIdName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 23 Description Defines the ID to be sent to the alphanumeric pager to inform the user of a call by this remote access user Syntax DisplayString SIZE 0 31 Access Read write Remote User Admin Pager Alpha Password Name Name remot eUserAdminPagerAlphaPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 24 Description Defines the password for the alphanumeric pager for this remote access user Syntax DisplayString SIZE 0 31 Access Read write Remote AccessGroup__ 449 Remote User Admin Pager Modem Init String Name Name remot eUserAdminPagerModemInitStringName Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 25 Description Defines the initialization string to be sent to the pager modem for this remote access user Syntax DisplayString SIZE 0 31 Access Read write Remote User Admin Pager Modem Port Name remot eUserAdminPagerModemPort Object ID 1 3 6 1 4 1 674 10892 1 1700 20 1 26 Description Defines the port for the pager modem for this remote access user Syntax DellUnsigned32BitRange Access R
429. ply event are provided Memory device messages provide status and warning information for memory modules present in a particular system Memory devices determine health status by counting the number of ECC memory corrections K NOTE A value of failure or non recoverable does not indicate a system 652 Traps failure or loss of data but rather that the specified system exceeded the specified ECC correction threshold Although the system continues to function you should perform system maintenance as described in Table 25 10 Table 25 10 Memory Device Messages Trap ID Description Severity Cause 1403 Memory device status is Warning A memory device correction lt status gt rate exceeded an acceptable Memory devise ro ation value oa TRAL device lt Location in chassis gt st tus AOLO CANON ars provided Possible memory module event cause lt list of causes gt 1404 Memory device status is Error A memory device correction lt Status gt Memory device location lt Location in chassis gt Possible memory module event cause lt list of causes gt rate exceeded an acceptable value a memory spare bank was activated or a Uncorrectable Memory Event occurred The system continues to function normally except for a Uncorrectable Memory Event Clear the memory error on Uncorrectable Memory Event Replace the memory module identified in the message during the system s next scheduled maintenance The memo
430. port Information Chassis Index Name Object ID Description Syntax Access cooSupport InformationchassisIndex 1 3 6 1 4 1 674 10892 1 1600 100 1 1 Defines the index one based of this chassis DellObjectRange Read only COO Support Information Index Name Object ID Description Syntax Access cooSupportInformationIndex 1 3 6 1 4 1 674 10892 1 1600 100 1 2 Defines the index one based for this system s support information DellObjectRange Read only COO Support Information State Name Object ID Description Syntax Access cooSupportiInformationState 1 3 6 1 4 1 674 10892 1 1600 100 1 3 Defines the support information state for this system DellStateSettings Read only COO Support Information Is Outsourced Name Object ID Description Syntax Access cooSupport InformationIsOut sourced 1 3 6 1 4 1 674 10892 1 1600 100 1 4 Specifies whether the support for this system is outsourced or not DellBoolean Read write Cost of Ownership Group 421 COO Support Information Type Name cooSupport InformationType Object ID 1 3 6 1 4 1 674 10892 1 1600 100 1 5 Description Defines the type of component system or network problem that occurred Syntax DellUnsigned32BitRange Access Read write COO Support Information Help Desk Name Name cooSupport InformationHelpDeskName Object ID 1 3 6 1 4 1 674 10892 1 1600 100 1 6 Description Defines the help desk information provided Syntax DellCos
431. pport Power Management Enable PME signal The system slot can support all slot capabilities 318 Slot Group Table 14 2 System Slot State Settings Variable Name De11SystemSlotStateSettings Data Type Integer Possible Data Values Meaning of Data Value sys sys sys sys sys sys sys sys 16 temSlotHot PlugIsUnknown 1 temSlotHot PlugIsHotPluggable 2 temSlotHot PlugIsPoweredOn 4 temSlotHotPlugIsAtAttention 8 temSlotHotPlugIsHotPluggable 2 temSlotHot PlugIsPoweredoOn 4 temSlotHotPlugIsAtAttention 8 temSlotHotPlugHasPowerFaulted The system slot s capabilities are unknown The system slot supports hot plug The system slot power and corresponding LED can be powered on The system slot attention state and corresponding LED can be set The system slot supports hot plug The system slot power and corresponding LED is on The system slot attention state and corresponding LED is on Power on fault and corresponding LED was detected due to a short or overcurrent systemSlotHotPlugAdapterIsPresent Adapter card present in slot 32 may not be powered systemSlotHot PlugAdapterPresentAnd Adapter card present in slot PoweredOn 36 systemSlotHot PlugPowerButtonPressed 64 sys sys sys temSlotProvides5Volts 128 temSlotProvides3Point3Volts 256 temSlotIsShared 512 and powered The syste
432. ption Syntax Access processorDeviceExtendedCapabilities 1 3 6 1 4 1 674 10892 1 1100 30 1 21 This attribute defines extended capabilities of the processor device This attribute is a bit field where a bit has the meaning defined below when set to 1 one Bit Position Meaning if Set Bit 0 Virtualization Technology VT supported Bit 1 Demand Based Switching DBS supported Bit 2 eXecute Disable XD supported Bit 3 Hyper Threading HT supported DellUnsigned16BitRange Read only Processor Device Extended Settings Name Object ID Description Syntax Access processorDeviceExtendedSettings 1 3 6 1 4 1 674 10892 1 1100 30 1 22 This attribute defines extended settings of the processor device This attribute is a bit field where a bit has the meaning defined below when set to 1 one Bit Position Meaning if Set Bit 0 Virtualization Technology VT enabled Bit 1 Demand Based Switching DBS enabled Bit 2 eXecute Disable XD enabled Bit 3 Hyper Threading HT enabled DellUnsigned16BitRange Read only Device Group 255 Processor Device Brand Name Name Object ID Description Syntax Access processorDeviceBrandName 1 3 6 1 4 1 674 10892 1 1100 30 1 23 Defines the brand of the processor device DellString Read only Processor Device Model Name Name Object ID Description Syntax Access processorDeviceModelName 1 3 6 1 4 1 674 10892 1 1100 30 1 24 Defines the model of the processor device
433. r supply DellPowerSupplyStateCapabilitiesUnique See Table 8 1 Read only Power Supply State Settings Unique Name powerSupplyStateSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 600 12 1 4 Description Defines the state and settings of the power supply Syntax DellPowerSupplyStateSettingsUnique See Table 8 2 Access Read write Power Supply Status Name powerSupplyStatus Object ID 1 3 6 1 4 1 674 10892 1 600 12 1 5 Description Defines the status of the power supply Syntax DellStatus Access Read only Power Group 145 Power Supply Output Watts Name Object ID Description Syntax Access Power Supply Type Name Object ID Description Syntax Access powerSupplyOutputWatts 1 3 6 1 4 1 674 10892 1 600 12 1 6 Defines the maximum sustained output wattage of the power supply in tenths of watts DellSigned32BitRange Read only powerSupplyType 1 3 6 1 4 1 674 10892 1 600 12 1 7 Defines the type of power supply DellPowerSupply Type See Table 8 3 Read only Power Supply Location Name Name Object ID Description Syntax Access powerSupplyLocationName 1 3 6 1 4 1 674 10892 1 600 12 1 8 Defines the location name of the power supply DellString Read only Power Supply Input Voltage Name Object ID Description Syntax Access powerSupplyInputVoltage 1 3 6 1 4 1 674 10892 1 600 12 1 9 Defines the input voltage to the power supply in volts DellSigned32BitRange Read only 146
434. r the modem used by this remote access dial up functionality Syntax DellUnsigned32BitRange Access Read write Remote User Dial In Configuration Table Name remoteUserDialincfgTable Object ID 1 3 6 1 4 1 674 10892 1 1700 50 Description Defines the Remote Access User Dial In Configuration Table Syntax SEQUENCE OF Remote UserDialInCfgTableEntry Access Not accessible Remote User Dial In Configuration Table Entry Name remoteUserDialiInCfgTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 Description Defines the Remote Access User Dial In Configuration Table entry Syntax RemoteUserDiallnCfgTableEntry Access Not accessible Index remoteUserDiallnCfgChassisIndex remoteUserDiallnCfgAdapterIndex remoteUserDiallnCfgUserIndex 460 Remote Access Group Remote User Dial In Configuration Chassis Index Name remoteUserDialiIncfgChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellObjectRange Access Read only Remote User Dial In Configuration Adapter Index Name remot eUserDialiIncfgAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 2 Description Defines the index one based of the remote access hardware that supports this remote access dial in user Syntax DellObjectRange Access Read only Remote User Dial In Configuration User Index Name remot eUserDialiIncfgUserIndex Object ID 1 3 6
435. rageProbelypelsDiscrete a value is not returned for this attribute Syntax DellSigned32BitRange Access Read only Amperage Probe Type Name amperageProbeType Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 7 Description Defines the type of the amperage probe Syntax DellAmperageProbeType Access Read only Amperage Probe Location Name Name Object ID Description Syntax Access amperage ProbeLocat ionName 1 3 6 1 4 1 674 10892 1 600 30 1 8 Defines the location name of the amperage probe in this chassis DellString Read only Power Group 155 Amperage Probe Upper Nonrecoverable Threshold Name amperageProbeUpperNonRecoverableThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 9 Description Defines the value of the amperage probe s upper nonrecoverable threshold The value is an integer representing the amperage in milliamperes that the probe is reading Syntax DellSigned32BitRange Access Read only Amperage Probe Upper Critical Threshold Name amperageProbeUpperCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 10 Description Defines the value of the amperage probe s upper critical threshold Syntax DellSigned32BitRange Access Read only Amperage Probe Upper Noncritical Threshold Name amperageProbeUpperNonCriticalThreshold Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 11 Description Defines the user assigned value of the amperage probe s upper critical threshold Syntax DellSigned32BitRange
436. re Type continued Variable Name De11FirmwareType Data Type Integer Possible Data Values Meaning of Data Value rac 16 The firmware type is Remote Access Controller iDRAC 17 The firmware type is Integrated Dell Remote Access Controller Table 5 22 Baseboard Type Variable Name De1 1BaseBoardType Data Type Integer Possible Data Values Meaning of Data Value unknown 1 The baseboard type is unknown other 2 The baseboard type is not one of the following types serverBlade 3 The baseboard type is a server blade connectivitySwitch 4 The baseboard type is a connectivity switch systemManagementModule 5 The baseboard type is a system management module processorModule 6 The baseboard type is a processor module ioModule 7 The baseboard type is an I O module memoryModule 8 The baseboard type is a memory module daughterBoard 9 The baseboard type is a daughter board motherboard 10 The baseboard type is a mother board processorMemoryModule 11 The baseboard type is a processor or memory module processorIOModule 12 The baseboard type is a processor or I O module interconnectBoard 13 The baseboard type is an interconnect board Chassis Information Group 111 112 Table 5 23 Baseboard Feature Flags Variable Name De 1 1BaseBoardFeatureFlags Data Type Integer Possible Data Values Meaning of Data Value NOTE These values are bit fields so combinatio
437. reManagementModuleConnectionEnclosure Number 1 3 6 1 4 1 674 10893 1 20 130 14 1 5 Identifies the instance number of the enclosure in the enclosureTable to which this enclosure memory module belongs Integer Read only Storage Management Group 595 Battery Table This table describes available properties for each controller battery on the managed system The following object sets up the Battery Table Name batteryTable Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 Description Defines the battery table Syntax SEQUENCE OF BatteryEntry Access Not accessible Battery Entry Name batteryEntry Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 Description Defines the battery table entry Syntax BatteryEntry Access Not accessible Index batteryNumber Battery Number Name batteryNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 1 Description Identifies the instance number of the battery entry Syntax Integer Access Read only 596 Storage Management Group Battery Name Name batteryName Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 2 Description Identifies the battery s name as represented in Storage Management Syntax DisplayString Access Read only Battery Vendor Name batteryVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 3 Description Identifies the battery s re seller s name Syntax DisplayString Access Read only Battery State Name batteryState Object ID 1 3 6 1 4 1 674 10893 1 20 130 15 1 4 Descripti
438. represented in Storage Management Syntax DisplayString Access Read only Temperature Probe Vendor Name temperatureProbeVendor Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 3 Description Identifies the temperature probe s re seller s name Syntax DisplayString Access Read only Temperature Probe State Name temperatureProbeState Object ID 1 3 6 1 4 1 674 10893 1 20 130 11 1 4 Description Identifies the current state of the temperature probe Possible states 0 Unknown 1 Ready 2 Failed Minimum Failure Threshold Exceeded Maximum Failure Threshold Exceeded 4 Offline 6 Degraded Minimum Warning Threshold Exceeded Maximum Warning Threshold Exceeded 9 Inactive 21 Missing Syntax Integer Access Read only 582 Storage Management Group Temperature Probe Severity Name Object ID Description Syntax Access temperatureProbeSeverity 1 3 6 1 4 1 674 10893 1 20 130 11 1 5 This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Integer Read only Temperature Probe Unit Name Object ID Description Syntax Access temperatureProbeUnit 1 3 6 1 4 1 674 10893 1 20 130 11 1 6 The units that will be used to display temperatures for the temperature probe DisplayString Read only Temperature Probe Minimum Warning Name Object ID Description Syntax Access temperatureProbeMinWarning 1 3 6 1 4 1 674 10893 1
439. ription Syntax Access arrayDiskNegotiatedSpeed 1 3 6 1 4 1 674 10893 1 20 130 4 1 29 Indicates the speed at which the drive is actually running in MPS megabytes per second Integer Read only Array Disk Capable Speed Name Object ID Description Syntax Access arrayDiskCapableSpeed 1 3 6 1 4 1 674 10893 1 20 130 4 1 30 Indicates the maximum speed at which the drive is capable of negotiating in MPS megabytes per second Integer Read only Storage Management Group 559 Array Disk Smart Alert Indication Name arrayDiskSmartAlertIndication Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 31 Description Indicates whether the disk has received a predictive failure Possible values 1 No disk has not received a predictive failure alert 2 Yes disk has received a predictive failure alert Syntax Integer Access Read only Array Disk Manufacture Day Name arrayDiskManufactureDay Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 32 Description Indicates the day of the week 1 Sunday through 7 Saturday on which this disk was manufactured Syntax DisplayString Access Read only Array Disk Manufacture Week Name arrayDiskManufactureWeek Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 33 Description The week 1 through 53 in which this disk was manufactured Syntax DisplayString Access Read only 560 Storage Management Group Array Disk Manufacture Year Name arrayDiskManufactureYear Object I
440. ription Defines the Remote Access SNMP Trap Destination Table Syntax SEQUENCE OF RemoteSNMPTTrapTableEntry Access Not accessible Remote Access Group 451 Remote SNMP Trap Table Entry Name remoteSNMPTrapTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 Description Defines the Remote Access SNMP Trap Destination Table entry Syntax RemoteSNMPTrap TableEntry Access Not accessible Index remoteSNMPTrapChassisIndex remoteSNMPTrapAdapterIndex remoteSNMPTrapIndex Remote SNMP Trap Chassis Index Name remoteSNMPTrapChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellObjectRange Access Read only Remote SNMP Trap Adapter Index Name remoteSNMPTrapAdapteriIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 2 Description Defines the index one based of the remote access hardware that uses this SNMP trap destination Syntax DellObjectRange Access Read only 452 Remote Access Group Remote SNMP Trap Index Name remoteSNMPTrapIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 3 Description Defines the index one based of this remote access SNMP trap destination Syntax DellObjectRange Access Read only Remote SNMP Trap State Capabilities Name remoteSNMPTrapStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 30 1 4 Description Defines the state capabilities of this remote access SNMP trap
441. ription Severity Category Cause Supported ID by RAC Platform 1015 alertDrscSEL The RAC Major Error RAC All Warning has detected a detecteda new system new event event log with in the warning System severity Event Log detailed log with info is in Severity drsAlert Warning Message varbind 1016 alertDrscSEL The RAC Critical Error RAC All Critical has detected a detecteda new system new event event log with in the critical System severity Event Log detailed log with info is in Severity drsAlert Critical Message varbind 1017 alertDrscSEL The RAC Major Status RAC All 80 system detected percentFull event log system event is 80 log is 80 full full 1018 alertDrscSEL The RAC Major Status RAC All 90 system detected percentFull event log system event is 90 log is 90 full full 666 Traps Table 25 18 Enterprise specific Traps continued Trap Name Description Severity Category Cause Supported ID by RAC Platform 1019 alertDrscSEL The RAC Major Status RAC All 100 system detected percentFull event log system event is 100 log is 100 full full 1020 alertDrscSEL The RAC Information Error RAC All Normal has detected a detecteda new system new event event log with in the normal System severity Event Log detailed log with info is in Severity drsAlert Normal Message varbind BMC Traps The BMC monitors the system for critical events by communicating with various sensors on the system board and by send
442. ristics of each device connected to your computer and it finds and executes programs stored in locations other than the active directory backup A copy of a program or data file As a precaution you should back up your computer s hard drive on a regular basis Before making a change to the configuration of your computer you should back up important start up files from your operating system baud rate A measurement of data transmission speed For example modems are designed to transmit data at one or more specified baud rate s through the COM serial port of a computer beep code A diagnostic message in the form of a pattern of beeps from your computer s speaker For example one beep followed by a second beep and then a burst of three beeps is beep code 1 1 3 690 Glossary BGA Abbreviation for Ball Grid Array an IC package that uses an array of solder balls instead of pins to connect to a PC board binary A base 2 numbering system that uses 0 and to represent information The computer performs operations based on the ordering and calculation of these numbers BIOS Acronym for basic input output system Your computer s BIOS contains programs stored on a flash memory chip The BIOS controls the following Communications between the microprocessor and peripheral devices such as the keyboard and the video adapter Miscellaneous functions such as system messages bit The smallest unit of information interpr
443. rning action definition 474 memory device failure action definition 1006 automatic system recovery ASR action definition 1353 power supply warning action definition 1553 log near full action definition 1554 log full action definition 1603 processor warning action definition 1604 processor failure action definition 1703 battery warning action definition 1704 battery failure action definition DellUnsigned16BitRange Read only Local Response Agent Group 389 LRA Action Table User Application Name Name Object ID Description Syntax Access 1RAActionTableUserApplicationName 1 3 6 1 4 1 674 10892 1 1500 20 1 3 When the execute application value is set provides the following user assignable LRA information e Name of the user application executable path e File name to execute DisplayString SIZE 0 256 Read write LRA Action Table Settings Unique Name Object ID Description Syntax Access 1RAActionTableSettingsUnique 1 3 6 1 4 1 674 10892 1 1500 20 1 4 Defines the LRA settings DellLocalResponseAgentSettingsUnique See Table 17 3 Read write Local Response Agent Variable Values This section includes definitions for server administrator specific variable values used in this section Table 17 1 LRA Capabilities Definitions Variable Name De1 1LocalResponseAgentCapabilitiesUnique Data Type Integer Possible Data Values Meaning of Data Value
444. roduct InfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 7 Description Defines the name of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 63 Access Read only Remote Access Description Info Name Name remoteAccessDescriptionInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 8 Description Defines the description of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 255 Access Read only Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 9 Description Defines the version of the product providing the remote access functionality Syntax DellDisplayString SIZE 0 63 Access Read only Remote Access Control Capabilities Name remoteAccessControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 10 Description Defines the control capabilities of the remote access hardware Syntax DellRemoteAccessControlCapabilities See Table 19 2 Access Read only 436 Remote Access Group Remote Access Control Settings Name remoteAccessControlSettings Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 11 Description Defines the control settings of the remote access hardware Syntax DellRemoteAccessControlSettings See Table 19 3 Access Read write Remote Access Monitor Capabilities Name remoteAccessMonitorCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1700 10 1 12 Description D
445. rs to create and modify user accounts and to control which users can perform Set operations on managed systems User Security Group Table The User Security Group defines objects in the User Security MIB table User Security Table The following object sets up the User Security Table Name Object ID Description Syntax Access userSecurityTable 1 3 6 1 4 1 674 10892 1 800 Contains the database of users that are authorized to perform Set operations on a managed system UserSecurityTableEntry Not accessible User Security Table Entry Name Object ID Description Syntax Access Index userSecurityTableEntry 1 3 6 1 4 1 674 10892 1 800 1 Defines a row in the User Security Table UserSecurityTableEntry Not accessible userSecuritychassisIndex userSecurityIndex User Security Group 199 User Security Chassis Index Name userSecuritychassisIndex Object ID 1 3 6 1 4 1 674 10892 1 800 1 1 Description Defines the user security index one based of this chassis Syntax DellObjectRange Access Read only User Security Index Name userSecurityIndex Object ID 1 3 6 1 4 1 674 10892 1 800 1 2 Description Defines the user security index Syntax DellObjectRange Access Read only User Security User Name Name userSecurityUserName Object ID 1 3 6 1 4 1 674 10892 1 800 1 3 Description Defines the user security user name Syntax DellSecurityString Access Read only User Security Control Name Name
446. rticular system Name cooCostEventLogTable Object ID 1 3 6 1 4 1 674 10892 1 1600 30 Description Defines the COO Cost Event Log Table Syntax SEQUENCE OF COO CostEventLogTableEntry Access Not accessible COO Cost Event Log Table Entry Name cooCostEventLogTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 30 1 Description Defines the COO Cost Event Log Table entry Syntax cooCostEventLogTableEntry Access Not accessible Index cooCostEventLogchassisIndex cooCostEventLogIndex COO Cost Event Log Chassis Index Name cooCostEventLogchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 30 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only COO Cost Event Log Index Name cooCostEvent LogIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 30 1 2 Description Defines the index one based of the cost event log Syntax DellObjectRange Access Read only 406 Cost of Ownership Group COO Cost Event Log State Name cooCostEventLogState Object ID 1 3 6 1 4 1 674 10892 1 1600 30 1 3 Description Defines the cost event log state of this system Syntax DellStateSettings Access Read only COO Cost Event Log Duration Name cooCostEventLogDuration Object ID 1 3 6 1 4 1 674 10892 1 1600 30 1 4 Description Defines the duration of the event for this system Syntax DellUnsigned32BitRange Access Read write COO Cost Event Log Duration Type Name cooCostEvent LogDurat ionType Object ID 1
447. rvention and correction K NOTE Not all managed objects described in this guide are supported by all systems A MIB acts as a structured road map for managed objects As an Application Programming Interface API a MIB allows systems management tools to retrieve data maintained by an agent The server administrator MIB is divided into several major groups of managed objects Variable A variable is a component of a managed object A temperature probe for example has a variable to describe its capabilities its health or status and certain indexes that you can use to locate specific temperature probes One index for the probe would be the probe s chassis number Some systems may have multiple chassis one chassis for the central processing unit and another chassis for storage A chassis within a system can also have more than one temperature probe Variables for a temperature probe include its capabilities status chassis index and index One Based Index When an index is one based counting starts at 1 One based indexing counts the first instance as 1 the second index as 2 and so on Zero Based Index When an index is zero based counting starts at 0 Zero based indexing counts the first instance as 0 the second index as 1 and so on Fields Managed object variables contain fields In this reference guide managed object variables have the following fields defined Introduction 25 Name is the exact string by which t
448. rver administrator SNMP subagent see Traps 36 Introduction Instrumentation MIB Version Group The Instrumentation Management Information Base MIB Version Group defines the attributes that identify the version of the Instrumentation MIB supported by the systems management software The mIBMajorVersionNumber mIBMinorVersionNumber and mIBMaintenanceVersionNumber attributes are scalar objects meaning that they are not related to other MIB objects and are thus not placed in a table MIB Major Version Number Name mIBMajorVersionNumber Object ID 1 3 6 1 4 1 674 10892 1 1 1 0 Description Defines the major version number of the version of this MIB supported by the systems management software For example if the MIB version is 1 2 3 the major version number is 1 A major version number change indicates a major change in object functionality Syntax DellUnsigned8BitRange Access Read only Instrumentation MIB Version Group 37 MIB Minor Version Number Name mIBMinorVersionNumber Object ID 1 3 6 1 4 1 674 10892 1 1 2 0 Description Defines the minor version number of the version of this MIB supported by the systems management software For example if the MIB version is 1 2 3 the minor version number is 2 A minor revision provides additional support for new objects as well as problem fixes Syntax DellUnsigned8BitRange Access Read only MIB Maintenance Version Number Name mIBMaintenanceVersionNumber Object I
449. ry device status and location are provided Traps 653 Fan Enclosure Traps Some systems are equipped with a protective enclosure for fans Fan enclosure traps monitor enclosures for whether foreign objects are present and for how long a fan enclosure is absent from a chassis Table 25 11 Fan Enclosure Traps Trap Description Severity ID Cause Fan Enclosure Insertion 1452 Fan enclosure inserted Information into system Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Fan Enclosure Removal 1453 Fan enclosure removed Warming from system Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Fan Enclosure Extended Removal 1454 Fan enclosure removed Error from system for an extended amount of time Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt A fan enclosure has been inserted into the specified system The sensor location and chassis location are provided A fan enclosure has been removed from the specified system The sensor location and chassis location are provided A fan enclosure has been removed from the specified system for a user definable length of time The sensor location and chassis location are provided 654 Traps AC Power Cord Traps The AC power cord sensor monitors the presence of AC power for an AC power cord AC power cord traps provide sta
450. ry Configuration Table SEQUENCE OF PhysicalMemoryConfigTableEntry Not accessible Physical Memory Configuration Table Entry Name Object ID Description Syntax Access Index physicalMemoryConfigTableEntry 1 3 6 1 4 1 674 10892 1 1300 30 1 Defines the Physical Memory Configuration Table entry PhysicalMemoryConfig TableEntry Not accessible physicalMemoryConfigChassisIndex physicalMemoryConfigIndex MemoryGroup__ 333 Physical Memory Configuration Chassis Index Name Object ID Description Syntax Access physicalMemoryConfigChassisIndex 1 3 6 1 4 1 674 10892 1 1300 30 1 1 Defines the index one based of the chassis associated with the physical memory configuration DellObjectRange Read only Physical Memory Configuration Index Name Object ID Description Syntax Access physicalMemoryConfigIndex 1 3 6 1 4 1 674 10892 1 1300 30 1 2 Defines the index one based of the physical memory configuration DellObjectRange Read only Physical Memory Configuration State Capabilities Name Object ID Description Syntax Access physicalMemoryConfigStateCapabilities 1 3 6 1 4 1 674 10892 1 1300 30 1 3 Defines the state capabilities of the physical memory configuration DellPhysicalMemoryContigStateCapabilities Read only Physical Memory Configuration State Settings Name Object ID Description Syntax Access 334 physicalMemoryConfigStateSettings 1 3 6 1 4 1 674 10892 1 1300
451. s fi unknown 1 he dial out destination state settings are unknown enabled 2 The dial out destination is disabled or enabled notReady 4 The dial out destination is in the not ready state dialOut PPPAuthAnyEnabled 8 The dial out destination accepts any authentication type including clear text for PPP dialOutPPPAuthEncryptedEnabled 16 The dial out destination uses only encrypted passwords authentication type for PPP dialOutPPPAuthMschapEnabled 32 The dial out destination uses only MSCHAP authentication type for PPP Remote Access Group 481 482 Remote Access Group Cluster Group Clustering combines multiple systems in such a way that they provide services a single system cannot Clustering enhances higher availability scalability and management Higher availability is achieved by using failover clusters in which resources can automatically move between two or more systems in the event of a failure Scalability is achieved by balancing the load of an application across several computer systems Simpler management is achieved by using virtual servers as opposed to managing each individual computer system Cluster Group The Cluster Group defines attributes such as the number of systems in the cluster capabilities of the cluster type of cluster and name of the cluster Cluster Table The following table defines the attributes of the cluster Name clusterTable
452. s See Table 5 18 Read only Chassis NMI Button Control Settings Unique Name Object ID Description Syntax Access UUID Table chassisNMIButtonControlSettingsUnique 1 3 6 1 4 1 674 10892 1 300 10 1 45 Defines the current reading and allows setting of the NMI button control hardware DelINMIButtonControlSettings See Table 5 19 Read write These objects comprise the server administrator definitions for the Universal Unique Identifier UUID Name Object ID Description Syntax Access uUIDTable 1 3 6 1 4 1 674 10892 1 300 20 Defines the UUID table SEQUENCE OF UUIDTableEntry Not accessible Chassis Information Group 77 UUID Table Entry Name uUIDTableEntry Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 Description Defines the UUID table entry Syntax UUIDTableEntry Access Not accessible Index uUID Index uUIDchassisIndex UUID Chassis Index Name uUIDchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only UUID Index Name uUIDIndex Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 2 Description Defines the index of the UUID in a specified chassis Syntax DellObjectRange Access Read only UUID Type Name uUIDType Object ID 1 3 6 1 4 1 674 10892 1 300 20 1 3 Description Defines the type of the UUID for this chassis Syntax DellUUIDType Access Read only 78 Chassis Information Group U
453. s Group provides information about remote 1700 access hardware that may be present in your system and defines variables for administrative users SNMP trap destinations modem configuration for dial up networking dial in configuration and dial out destinations Server Administrator Baseboard Management Controller ASF MIB The Server Administrator BMC MIB filename DcAsfSrv mib provides information about the traps sent by BMC The Server Administrator BMC MIB structures its MIB objects that provide related information The BMC MIB groups are identified by the SNMP OID 1 3 6 1 4 1 3183 1 1 lt MIB group number gt The BMC MIB is adheres to ASF 2 0 standard and hence the enterprise ID is wired for management 3183 Server Administrator Field Replaceable Unit MIB The Server Administrator Field Replaceable Unit MIB filename dcs3fru mib provides information about field replaceable unit FRU hardware that may be present in your system The Server Administrator Field Replaceable Unit MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information Table 1 4 describes each Server Administrator Field Replaceable Unit MIB group and lists the MIB group number assigned to the MIB group The Server Administrator Field Replaceable Unit MIB groups are identified by the SNMP OID 1 3 6 1 4 1 674 10892 1 lt MIB group number gt where lt MIB group number gt is the MIB group number assigned to the MIB gr
454. s Index Name remoteFlashBIOSchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Remote Flash BIOS Index Name remoteFlashBIOSIndex Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 2 Description Defines the index to the remote BIOS update hardware on this system Syntax DellObjectRange Access Read only Remote Flash BIOS State Capabilities Unique Name remoteFlashBIOSStateCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 3 Description Defines the capabilities of the remote BIOS update hardware on this system Syntax DellRemoteFlashBIOSStateCapabilitiesUnique See Table 11 1 Access Read only Remote Flash BIOS State Settings Unique Name remoteFlashBlOSStateSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 4 Description Defines the state and settings of the remote BIOS update hardware on this system Syntax DellRemoteFlashBIOSStateSettingsUnique See Table 11 2 Access Read write 204 Remote Flash BIOS Group Remote Flash BIOS Status Name remoteFlashBIOSStatus Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 5 Description Defines the status of the remote BIOS update hardware on this system Syntax DellRemoteFlashBIOSStateStatus Access Read only Remote Flash BIOS Last BIOS Date Name Name remoteFlashBIOSLastBIOSDateName Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 6 Description Defines the date
455. s are still operating Redundancy is lost when the number of components functioning falls below the redundancy threshold The number of devices required for full redundancy is provided as part of the trap message when applicable for the redundancy unit and the platform For more details on redundancy computation please refer to the respective platform documentation Table 25 8 Redundancy Unit Traps Trap ID Description Severity Cause Redundancy Normal 1304 Redundancy regained Information A redundancy sensor in the specified system detected that a lost redundancy device has been reconnected or replaced full redundancy is in effect The redundancy unit location chassis Previous redundancy location and previous state was lt State gt redundancy state are provided Redundancy unit lt Redundancy location in chassis gt Chassis location lt Name of chassis gt Number of devices required for full redundancy lt Number gt 648 Traps Table 25 8 Redundancy Unit Traps continued Trap ID Description Severity Cause Redundancy Degraded 1305 Redundancy degraded Warning A redundancy sensor in the Redundancy unit lt Redundancy location in chassis gt Chassis location lt Name of chassis gt Previous redundancy state was lt State gt Number of devices required for full redundancy lt Number gt Redundancy Lost 1306 Redundancy lost Redundancy unit lt Redundancy location in
456. s not supported in Storage Management Syntax Integer Access Read only 524 Storage Management Group Controller CO Channel Name controllerCOChannel Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 23 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller CO Operating System Controller Name controllercooSController Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 24 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller CO Battery State Name controllercoOBatteryState Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 25 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax Integer Access Read only Controller C1 Port 0 World Wide Name Name controllerC1Port OWWN Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 26 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Storage Management Group 525 Controller C1 Port 0 Name Name controllerC1Port 0OName Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 27 Description This entry is obsolete Fibre channel is not supported in Storage Management Syntax DisplayString Access Read only Controller C1 Port 0 ID Name controllerC1Port0ID Object ID 1 3 6 1 4 1 674 10893 1 20 130 1 1 28 Descripti
457. s numeric paging The admin user supports alphanumeric paging he admin user supports e mail The admin user supports user privileges configuration 412 Remote Access Group Table 19 13 Remote User Admin State Settings Variable Name Del 1RemoteUserAdminStateSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The admin user has no state settings unknown 1 The admin user state settings are unknown enabled 2 The admin user is enabled notReady 4 The admin user is in the not ready state numericPagerEnabled 8 Numeric paging is enabled for the admin user alphaPagerEnabled 16 Alphanumeric paging is enabled for the admin user emailEnabled 32 E mail is enabled for the admin user Table 19 14 Remote User Admin Control Capabilities Variable Name De1 1RemoteUserAdminControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The admin user has no control capabilities unknownCapabilities 1 The admin user control capabilities are unknown numericPagerTestCapable 2 The admin user can support sending a test numeric page alphaPagerTestCapable 4 The admin user can support sending a test alphanumeric page emailTestCapable 8 The admin user can support sending a test e mail Remote Access Group 473 Table 19 15 Remote User Admin Control Settings Variable Name De 1 LRemoteUserAdminCo
458. s remote access dial in user Syntax DisplayString SIZE 0 15 Access Read write 462 Remote Access Group Remote User Dial In Configuration Callback Phone Number Name Name remoteUserDialiIncfgCallbackPhoneNumberName Object ID 1 3 6 1 4 1 674 10892 1 1700 50 1 9 Description Defines the callback phone number for this remote access dial in user Syntax DisplayString SIZE 0 95 Access Read write Remote Dial Out Table Name remoteDialOutTable Object ID 1 3 6 1 4 1 674 10892 1 1700 60 Description Defines the Remote Access Dial Out Table Syntax SEQUENCE of RemoteDialOutTableEntry Access Not accessible Remote Dial Out Table Entry Name remoteDialOutTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 Description Defines the Remote Access Dial Out Table entry Syntax RemoteDialOutTableEntry Access Not accessible Index remoteDialOutChassisIndex remoteDialOutAdapterIndex remoteDialOutDialOutIndex Remote Dial Out Chassis Index Name remoteDialOutChassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 1 Description Defines the index one based of the chassis containing the remote access hardware Syntax DellObjectRange Access Read only Remote Access Group __ 463 Remote Dial Out Adapter Index Name remoteDialOutAdapterIndex Object ID 1 3 6 1 4 1 674 10892 1 1700 60 1 2 Description Defines the index one based of the remote access hardware that supports this remote access dial out functionality
459. s the location name of the baseboard Syntax DellString Access Read only Baseboard Manufacturer Name Name baseBoardManufacturerName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 10 Description Defines the baseboard manufacturer s name Syntax DellString Access Read only Baseboard Product Name Name baseBoardProductName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 11 Description Defines the baseboard product s name Syntax DellString Access Read only 98 Chassis Information Group Baseboard Version Name Name baseBoardVersionName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 12 Description Defines the baseboard version name Syntax DellString Access Read only Baseboard Service Tag Name Name baseBoardServiceTagName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 13 Description Defines the baseboard service tag name Syntax DellString Access Read only Baseboard Piece Part ID PPID Name Name baseBoardPiecePart IDName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 14 Description Defines the baseboard PPID Syntax DellString Access Read only Baseboard Asset Tag Name Name baseBoardAssetTagName Object ID 1 3 6 1 4 1 674 10892 1 300 80 1 15 Description Defines the baseboard asset tag name Syntax DellString Access Read only Chassis Information Group 99 Chassis Information Group Variable Values This section includes definitions for server administrator specific variable values used in this section Table 5 1
460. s what printer s and fonts are installed for Windows The win ini file also usually includes sections that contain optional settings for Windows application programs that are installed on the hard drive Running the Control Panel or Windows Setup program may change options in the win ini file On other occasions you may need to change or add options to the win ini file manually with a text editor such as Notepad Windows 95 An integrated and complete Microsoft Windows operating system that provides advanced operating system performance improved ease of use enhanced workgroup functionality and simplified file management and browsing Windows NT High performance server and workstation operating system software developed by Microsoft that is intended for technical engineering and financial applications write protected Read only files are said to be write protected You can write protect a 3 5 inch diskette by sliding its write protect tab to the open position or by setting the write protect feature in the System Setup program XMM Abbreviation for extended memory manager a utility that allows application programs and operating systems to use extended memory in accordance with the XMS Glossary 725 XMS Abbreviation for eXtended Memory Specification ZIF Acronym for zero insertion force Some computers use ZIF sockets and connectors to allow devices such as the microprocessor chip to be installed or removed with no str
461. sPentium4 22 The processor family is Pentium 4 deviceFamilyIsIntelXeonMP 23 The processor family is Intel Xeon MP deviceFamilyIsIntelItanium2 24 The processor family is Intel Itanium 2 deviceFamilyIsK5 25 The processor family is K5 deviceFamilyIsk 6 26 The processor family is K6 deviceFamilyIsk 6 2 27 The processor family is K6 2 deviceFamilyIsk 6 3 28 The processor family is K6 3 deviceFamilyIsAMDAthlon 29 The processor family is AMD Athlon deviceFamilyIsAMD2900 30 The processor family is AMD2900 deviceFamilyIsk6 2Plus 31 The processor family is K6 2 deviceFamilyIsPowerPC 32 The processor family is Power PC deviceFamilyIsPowerPC601 33 The processor family is Power PC 601 296 Device Group Table 13 6 Processor Device Family continued Variable Name De11ProcessorDeviceFamily Data Type Integer Possible Data Values Meaning of Data Value deviceFamilyIsPowerPC603 34 deviceFamilyIsPowerPC603Plus 35 deviceFamilyIsPowerPC604 36 deviceFamilyIsPowerPC620 37 deviceFamilyIsPowerPCx704 38 deviceFamilyIsPowerPC750 39 deviceFamilyIsAlpha 48 deviceFamilyIsAlpha21064 49 deviceFamilyIsAlpha21066 50 deviceFamilyIsAlpha21164 51 deviceFamilyIsAlpha21164PC 52 deviceFamilyIsAlpha21164a 53 deviceFamilyIsAlpha21264 54 deviceFamilyIsAlpha21364 55 deviceFamilyIsMIPS 64 deviceFamilyIsMIPSR4000 65 deviceFamilyIsMIPSR4200 66 deviceFamilyIsMIPSR440
462. scription Defines the COO Options Table Syntax SEQUENCE OF CooOptionsTableEntry Access Not accessible 414 Cost of Ownership Group COO Options Table Entry Name Object ID Description Syntax Access Index cooOptionsTableEntry 1 3 6 1 4 1 674 10892 1 1600 70 1 Defines the COO Options Table entry CooOptions TableEntry Not accessible cooOptionschassisIndex cooOptionsIndex COO Options Chassis Index Name cooOptionschassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 70 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only COO Options Index Name cooOptionsIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 70 1 2 Description Defines the index one based of the option information for this system Syntax DellObjectRange Access Read only COO Options State Name cooOptionsState Object ID 1 3 6 1 4 1 674 10892 1 1600 70 1 3 Description Defines the option information state for this system Syntax DellStateSettings Access Read only Cost of Ownership Group 415 COO Options Lease Information Index Reference Name cooOpt ionsLeaseInformat ionIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1600 70 1 4 Description Defines the lease information index of the option information for this system Syntax DellUnsigned32BitRange Access Read write COO Options Description Name Name cooOptionsDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 1600 70 1 5 Descr
463. sed of this chassis Syntax DellObjectRange Access Read only COO Service Contract Index Name cooServiceContract Index Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 2 Description Defines the index one based of this service contract Syntax DellObjectRange Access Read only 404 Cost of Ownership Group COO Service Contract State Name cooServiceContractState Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 3 Description Defines the status of the service contract for this system Syntax DellStateSettings Access Read only COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 4 Description Specifies whether the service contract for this system was renewed Syntax DellBoolean Access Read write COO Service Contract Type Name Name cooServiceContractTypeName Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 5 Description Defines the name of the service contract type for this system Syntax DellCostofOwnershipString Access Read write COO Service Contract Vendor Name Name cooServiceContractVendorName Object ID 1 3 6 1 4 1 674 10892 1 1600 20 1 6 Description Defines the name of the service contract provider for this system Syntax DellCostofOwnershipString Access Read write Cost of Ownership Group 405 COO Cost Event Log Table The COO Cost Event Log Table provides MIB objects that allow you to track the duration and type of events that are logged for a pa
464. seller s name Syntax DisplayString Access Read only Enclosure State Name enclosureState Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 4 Description The current condition of the enclosure which includes any devices connected to it Possible values 0 Unknown 1 Ready 2 Failed 3 Online 4 Offline 6 Degraded Syntax Integer Access Read only 540 Storage Management Group Enclosure Severity Name Object ID Description Syntax Access Enclosure ID Name Object ID Description Syntax Access enclosureSeverity 1 3 6 1 4 1 674 10893 1 20 130 3 1 5 This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Integer Read only enclosureID 1 3 6 1 4 1 674 10893 1 20 130 3 1 6 Identifies the SCSI address of the processor Integer Read only Enclosure Processor Version Name Object ID Description Syntax Access enclosureProcessorVersion 1 3 6 1 4 1 674 10893 1 20 130 3 1 7 This entry is obsolete for Storage Management DisplayString Read only Enclosure Service Tag Name Object ID Description Syntax Access enclosureServiceTag 1 3 6 1 4 1 674 10893 1 20 130 3 1 8 The enclosure identification used when consulting customer support DisplayString Read only Storage Management Group 541 Enclosure Asset Tag Name enclosureAssetTag Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 9 Description Customer def
465. sis gt Chassis location lt Name of chassis gt Previous state was lt State gt Fan sensor value lt Reading gt 640 Traps Severity Information Cause A fan sensor reading on the specified system returned to a valid range after crossing a warning threshold The sensor location chassis location previous state and fan sensor value are provided Table 25 4 Cooling Device Traps continued Trap ID Description Severity Cause Cooling Device Warning an sensor detected a amin an sensor readin 1103 F detected W g Af ding warning value in the specified ensor Tae Mes system exceeded a siocation in ehdssiss warning threshold The sensor location chassis location lt Name of chassis location chassis gt previous state and Previous state was lt State gt fan sensor value are rovided Fan sensor value lt Reading gt P Cooling Device Failure an sensor detected a ATTOr an sensor in the 1104 F detected E Af t failure value specified system serao location detected the failure a ea An eha sadas of one or more fans The sensor location chassis location lt Name of chassis location chassis gt previous state and Previous state was lt State gt fan sensor value are f rovided Fan sensor value lt Reading gt P Cooling Device Nonrecoverable 1105 Fan sensor detected a Error A fan sensor detected non recoverable value Sensor location lt Location in chassis gt Chassis location lt Name of
466. skettes from which they copy themselves to the hard drive To guard against virus programs you should do the following e Periodically run a virus checking utility on your computer s hard drive e Always run a virus checking utility on any diskettes including commercially sold software before using them VLSI Abbreviation for very large scale integration VLVESA Acronym for very low voltage enterprise system architecture vpp Abbreviation for peak point voltage VRAM Acronym for video random access memory Some video adapters use VRAM chips or a combination of VRAM and DRAM to improve video performance VRAM is dual ported allowing the video adapter to update the screen and receive new image data at the same time VRM Abbreviation for voltage regulator module W Abbreviation for watt s 724 Glossary Wakeup on LAN The ability for the power in a client station to be turned on by the network Remote wake up enables software upgrading and other management tasks to be performed on users machines after the work day is over It also enables remote users to gain access to machines that have been turned off Intel calls remote wake up Wake on LAN WH Abbreviation for watt hour s win ini file A start up file for the Windows operating system When you start Windows it consults the win ini file to determine a variety of options for the Windows operating environment Among other things the win ini file record
467. spare HPFS Abbreviation for the High Performance File System option in the Windows NT operating systems Hz Abbreviation for hertz ICES Abbreviation for Interface Causing Equipment Standard in Canada ICU Abbreviation for ISA Configuration Utility IDE Abbreviation for Integrated Device Electronics IDE is a computer system interface used primarily for hard drives and CDs 1 0 Abbreviation for input output The keyboard is an input device and a printer is an output device In general I O activity can be differentiated from computational activity For example when a program sends a document to the printer it is engaging in output activity when the program sorts a list of terms it is engaging in computational activity ID Abbreviation for identification IHV Acronym for independent hardware vendor IHVs often develop their own MIBs for components that they manufacture interlacing A technique for increasing video resolution by only updating alternate horizontal lines on the screen Because interlacing can result in noticeable screen flicker most users prefer noninterlaced video adapter resolutions 702 Glossary internal microprocessor cache An instruction and data cache built in to the microprocessor The Intel Pentium microprocessor includes a 16 KB internal cache which is set up as an 8 KB read only instruction cache and an 8 KB read write data cache IP Address Abbreviation for Internet Protocol
468. ssible ThermalGroup 189 Temperature Probe Table Entry Name temperatureProbeTableEntry Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 Description Defines the Temperature Probe Table entry Syntax TemperatureProbe TableEntry Access Not accessible Index temperatureProbechassisIndex temperatureProbelndex Temperature Probe Chassis Index Name temperatureProbechassisIndex Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Temperature Probe Index Name temperatureProbeIndex Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 2 Description Defines the index of temperature probes in this chassis Syntax DellObjectRange Access Read only Temperature Probe State Capabilities Name temperatureProbeStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 700 20 1 3 Description Defines the capabilities of the temperature probe Syntax DellStateCapabilities Access Read only 190 Thermal Group Temperature Probe State Settings Name Object ID Description Syntax Access temperatureProbeStateSettings 1 3 6 1 4 1 674 10892 1 700 20 1 4 Defines the state and settings of the temperature probe DellStateSettings Read write Temperature Probe Status Name Object ID Description Syntax Access temperatureProbeStatus 1 3 6 1 4 1 674 10892 1 700 20 1 5 Defines the status of the temperature probe in tenths of degrees Celsius
469. ssis DellUnsigned8BitRange Read only Chassis ID Extension Name chassisIDExtension Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 13 Description Defines the SMBIOS machine ID of this chassis Syntax DellUnsigned1 6BitRange Access Read only Chassis System Class Name chassisSystemClass Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 14 Description Defines the chassis class of this chassis Syntax DellChassisSystemClass See Table 5 20 Access Read only Chassis System Name Name Object ID Description Syntax Access chassisSystemName 1 3 6 1 4 1 674 10892 1 300 10 1 15 Defines the system name of this chassis DellString Read only Chassis Information Group 69 Chassis System Boot Date Name Name chassisSystemBootDateName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 16 Description Defines the boot time of this system Syntax DellDateName Access Read only Chassis System Date Name Name chassisSystemDateName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 17 Description Defines the current time on this system Syntax DellDateName Access Read only Chassis System Location Name Name chassisSystemLocationName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 18 Description Defines the user assigned location for this chassis Syntax DellString Access Read write Chassis System Primary User Name Name chassisSystemPrimaryUserName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 19 Description Defines the user assigned primary us
470. ssisPowerButtonControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 39 Description Defines the current reading and allows setting of the power button control hardware Syntax DellPowerButtonControlSettings See Table 5 17 Access Read write Chassis Reseller Name Name chassisResellerName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 40 Description Defines the name of the chassis reseller Syntax DisplayString SIZE 0 128 Access Read only Chassis Reseller Contact Information Name Name chassisResellerContactInformationName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 41 Description Defines the chassis reseller contact information name Syntax DisplayString SIZE 0 128 Access Read only Chassis Reseller Product Name Name chassisResellerProductName Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 42 Description Defines the chassis reseller product name Syntax DisplayString SIZE 0 128 Access Read only 76 Chassis Information Group Chassis Reseller System ID Name Object ID Description Syntax Access chassisResellerSystemID 1 3 6 1 4 1 674 10892 1 300 10 1 43 Defines the chassis reseller system ID DellUnsigned16BitRange Read only Chassis NMI Button Control Capabilities Unique Name Object ID Description Syntax Access chassisNMIButtonControlCapabilitiesUnique 1 3 6 1 4 1 674 10892 1 300 10 1 44 Defines the capabilities of the NMI button control function DelINMIButtonControlCapabilitie
471. ssorDeviceStatusStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 32 1 3 Defines the state capabilities of the processor device status probe DellStateCapabilities Read only Processor Device Status State Settings Name Object ID Description Syntax Access processorDeviceStatusStateSettings 1 3 6 1 4 1 674 10892 1 1100 32 1 4 Defines the state settings of the processor device status probe DellStateSettings Read write Processor Device Status Status Name Object ID Description Syntax Access processorDeviceStatusStatus 1 3 6 1 4 1 674 10892 1 1100 32 1 5 Defines the status of the processor device status probe This status will be joined into the processorDeviceStatus attribute DellStatus Read only Processor Device Status Reading Name Object ID Description Syntax Access 258 processorDeviceStatusReading 1 3 6 1 4 1 674 10892 1 1100 32 1 6 Defines the reading of the processor device status probe DellProcessorDeviceStatusReading Read only Device Group Processor Device Status Location Name Name Object ID Description Syntax Access processorDeviceStatusLocationName 1 3 6 1 4 1 674 10892 1 1100 32 1 7 Defines the location name of the processor device status probe DellString Read only Processor Device Status Port Index Reference Name Object ID Description Syntax Access processorDeviceStatusPort IndexReference 1 3 6 1 4 1 674 10892 1 1100 32 1 8 Defines the inde
472. st 1002 alertDrscAuth RAC Minor Error RAC login All Error Authentica failure caused tion by failures authenticatio during a n failure time number of period concurrent have logins exceed exceeded a limit or threshold permission denied 1003 alertDrscLost The RAC Critical Error RAC lost Dell ESM cannot communicati Remote communicate on with ESM Access with the Controller baseboard DRAC III management controller ESM 662 Traps Table 25 18 Enterprise specific Traps continued Trap Name Description Severity Category Cause Supported ID by RAC Platform 1004 alertDrscFound The RAC is Information Error RAC DRAC HI ESM communicat recovered ing communicati normally on with ESM with the baseboard management controller ESM 1005 alertDrscPower The RAC Critical Error RAC DRAC HI Off has detected a detecteda system power system state change power to power off state change to powered off 1006 alertDrscPower The RAC Information Error RAC DRAC HI On has detected a detecteda system power system state change power to power on state change to powered on Traps 663 Table 25 18 Enterprise specific Traps continued Trap Name Description Severity Category Cause Supported ID by RAC Platform 1007 alertDrsc The RAC Critical Event RAC has DRAC HI Watchdog has detected the Expired detected system that the watchdog system expired watchdog normally has indicating a expired system hang indicating
473. st of Ownership Group The Cost of Ownership COO Group provides a full set of cost tracking objects including fields for the computer s manufacturer insurer lessor warranty user trouble tickets and many others You can use these management information base MIB objects to obtain accurate and complete measurements of the cost of each computer asset in your organization Cost of Ownership Group Tables The Cost of Ownership Group defines objects in the following MIB tables e Cost of Ownership Table e COO Service Contract Table e COO Cost Event Log Table e COO Warranty Table e COO Lease Information Table e COO Schedule Number Table e COO Options Table e COO Maintenance Table COO Repair Table e COO Support Information Table e COO Trouble Ticket Table Cost of Ownership Table The following MIB object sets up the Cost of Ownership Table Name cooTable Object ID 1 3 6 1 4 1 674 10892 1 1600 10 Description Defines the Cost of Ownership Table Syntax SEQUENCE OF CooTableEntry Access Not accessible Cost of Ownership Group 393 Cost of Ownership Table Entry Name cooTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 Description Defines the Cost of Ownership Table entry Syntax CooTableEntry Access Not accessible Index coochassisIndex C00 Chassis Index Name coochassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 1 Description Defines the index one based of this chassis Syntax CooTableEntry Access
474. status of the array disk and its components Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable DellStatus Read only Storage Management Group 557 Array Disk Component Status Name arrayDiskComponentStatus Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 24 Description The status of the array disk itself without the propagation of any contained component status Possible values 1 Other 2 Unknown 3 OK 4 Non critical 5 Critical 6 Non recoverable Syntax DellStatus Access Read only Array Disk Device Name Name arrayDiskDeviceName Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 25 Description Identifies the operating system device name for this disk Syntax DisplayString Access Read only Array Disk Nexus ID Name arrayDiskNexusID Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 26 Description Indicates the durable unique ID for this array disk Syntax DisplayString Access Read only 558 Storage Management Group Array Disk Part Number Name arrayDiskPartNumber Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 27 Description Indicates the part number of the disk Syntax DisplayString Access Read only Array Disk SAS Address Name arrayDiskSASAddress Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 28 Description Indicates the specified SAS address if this is a SAS disk Syntax DisplayString Access Read only Array Disk Negotiated Speed Name Object ID Desc
475. stem Group Operating System Memory Status Name operatingSystemMemoryStatus Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 4 Description Defines the status of the operating system memory Syntax DellStatus Access Read only Operating System Memory Total Physical Size Name operatingSystemMemoryTotalPhysicalSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 5 Description Defines the total physical memory size in bytes Syntax DellUnsigned32BitRange Access Read only Operating System Memory Available Physical Size Name operatingSystemMemoryAvailablePhysicalSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 6 Description Defines the available physical memory size in bytes Syntax DellUnsigned32BitRange Access Read only Operating System Memory Total Page File Size Name operatingSystemMemoryTotalPageFileSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 7 Description Defines the total page file memory size in bytes Syntax DellUnsigned32BitRange Access Read only Operating System Group 117 Operating System Memory Available Page File Size Name operatingSystemMemoryAvailablePageFileSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 8 Description Defines the available page file memory size in bytes Syntax DellUnsigned32BitRange Access Read only Operating System Memory Total Virtual Size Name operatingSystemMemoryTotalVirtualSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 9 Description Defines the total virtual memory size in by
476. sting exclusively of ASCII characters Windows Notepad is a text editor for example Most word processors use proprietary file formats containing binary characters although some can read and write text files text mode A video mode that can be defined as x columns by y rows of characters threshold values Systems are normally equipped with various sensors that monitor temperature voltage current and fan speed The sensor s threshold values specify the ranges min and max values for determining whether the sensor is operating under normal noncritical critical or fatal conditions Dell supported threshold values are UpperThresholdFatal UpperThresholdCritical UpperThresholdNon critical Normal LowerThresholdNon critical LowerThresholdCritical LowerThresholdFatal Glossary 719 time out A specified period of system inactivity that must occur before an energy conservation feature is activated tpi Abbreviation for tracks per inch TOFP Acronym for thin quad flat pack TSR Abbreviation for terminate and stay resident A TSR program runs in the background Most TSR programs implement a predefined key combination sometimes referred to as a hot key that allows you to activate the TSR program s interface while running another program When you finish using the TSR program you can return to the other application program and leave the TSR program resident in memory for later use TSR programs can sometimes cause memory
477. t keeps a copy of data or instructions for quicker data retrieval For example your computer s BIOS may cache ROM code in faster RAM Or a disk cache utility may reserve RAM in which to store frequently accessed information from your computer s disk drives when a program makes a request to a disk drive for data that is in the cache the disk cache utility can retrieve the data from RAM faster than from the disk drive capability Refers to the actions that an object can perform or actions that can be taken on a managed object For example if a card is hot pluggable it is capable of being replaced while the system power is ON CDRAM Abbreviation for cached DRAM which is a high speed DRAM memory chip developed by Mitsubishi that includes a small SRAM cache CD ROM Abbreviation for compact disc read only memory CD drives use optical technology to read data from CDs CDs are read only storage devices you cannot write new data to a CD with standard CD drives 692 Glossary chip A set of microminiaturized electronic circuits that are designed for use as processors and memory in computers Small chips can hold from a handful to tens of thousands of transistors They look like tiny chips of aluminum no more than 1 16 square by 1 30 thick which is where the term chip came from Large chips which can be more than a half inch square hold millions of transistors It is actually only the top one thousandth of an inch of a chip s s
478. tLevel Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 8 Description Defines the interrupt request IRQ level of the system resource interrupt Syntax DellUnsigned32BitRange Access Read only System Resource Interrupt Type Name systemResourceInterruptType Object ID 1 3 6 1 4 1 674 10892 1 500 50 1 9 Description Defines the interrupt type of the system resource interrupt Syntax DellResourcelnterruptType See Table 7 5 Access Read only 132 System Resource Group System Resource Interrupt Trigger Name Object ID Description Syntax Access systemResourceInterruptTrigger 1 3 6 1 4 1 674 10892 1 500 50 1 10 Defines the interrupt trigger of the system resource interrupt DellResourcelnterruptTrigger See Table 7 6 Read only System Resource Direct Memory Access DMA Table Name Object ID Description Syntax Access systemResourceDMATable 1 3 6 1 4 1 674 10892 1 500 60 Defines the System Resource DMA Table SEQUENCE OF SystemResourceDMATableEntry Not accessible System Resource DMA Table Entry Name Object ID Description Syntax Access Index systemResourceDMATable 1 3 6 1 4 1 674 10892 1 500 60 1 Defines the System Resource DMA Table entry SystemResourceDMATableEntry Not accessible systemResourceDMAchassisIndex systemResourceDMAIndex System Resource DMA Chassis Index Name Object ID Description Syntax Access systemResourceDMAchassisIndex 1 3 6 1 4 1 674 10892 1 500 60 1 1 D
479. ta Values Meaning of Data Value systemSlotLengthIsOther 1 The system slot length is not one of following systemSlotLengthIsUnknown 2 The system slot length is unknown systemSlotLengthIsShort 3 The system slot length is short systemSlotLengthIsLong 4 The system slot length is long Table 14 6 System Slot Category Variable Name De11SystemSlotCategory Data Type Integer Possible Data Values Meaning of Data Value systemSlotCategoryIsOther 1 The system slot category is not one of following systemSlotCategoryIsUnknown 2 The system slot category is unknown systemSlotCategoryIsBusConnector 3 The system slot is a bus connector systemSlotCategoryIsPCMCIA 4 The system slot category is PCMCIA systemSlotCategoryIsMotherboard 5 The system slot is a motherboard Slot Group 323 Table 14 7 Hot Plug Bus Width Variable Name De1 1SystemSlotHotPlugBusWidth Data Type Integer Possible Data Values Meaning of Data Value busWidthIsOther 1 The system slot bus width is not one of following busWidthIsUnknown 2 The system slot bus width is unknown busWidthIs8bits 3 The system slot bus width is 8 bits busWidthIs1 bits 4 The system slot bus width is 16 bits busWidthIs32bits 5 The system slot bus width is 32 bits busWidthIs 4bits 6 The system slot bus width is 64 bits busWidthIs128bits 7 The system slot bus width is 128 bits busWidthIs1xOrx1 8 The system slot
480. tage Probe Failure 1154 Voltage sensor detected a Error failure value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Voltage sensor value in Volts lt Reading gt If sensor type is discrete Discrete voltage state lt State gt A voltage sensor in the specified system exceeded its warning threshold The sensor location chassis location previous state and voltage sensor value are provided A voltage sensor in the specified system exceeded its failure threshold The sensor location chassis location previous state and voltage sensor value are provided Traps 643 Table 25 5 Voltage Probe Traps continued Trap ID Description Severity Cause Voltage Probe Nonrecoverable 1155 Voltage sensor detected a Error A voltage sensor in the non recoverable value specified system Sefsorio ation detected an error from JL cation in chassiss which it cannot recover The sensor location Chassis location lt Name of chassis location chassis gt previous state and Previous state was voltage sensor value are lt State gt provided If sensor type is not discrete Voltage sensor value in Volts lt Reading gt If sensor type is discrete Discrete voltage state lt State gt Amperage Probe Traps Amperage probes measure the amount of current in amperes that is traversing critical
481. tage probe type is not one of the following voltageProbeTypeIsUnknown 2 The voltage probe type is unknown not known or not monitored voltageProbeTypeIs1Point5Volt The voltage probe type is a 1 5 volt V 3 probe Power Group 173 Table 8 6 Voltage Probe Type continued Variable Name De11VoltageType Data Type Integer Possible Data Values Meaning of Data Value voltageProbeTypelIs3Point3Volt 4 voltageProbeTypelIs5Volt 5 voltageProbeTypelIsMinus5Volt 6 voltageProbeTypelIsl2Volt 7 voltageProbeTypelIsMinus12Volt 8 voltageProbeTypeIsI0 9 voltageProbeTypelIsCore 10 voltageProbeTypeIsFLEA 11 voltageProbeTypelIsBattery 12 voltageProbeTypelIsTerminator 13 voltageProbeTypelIs2Point5Volt 14 voltageProbeTypeIsGTL 15 voltageProbeTypelIsDiscrete 16 The voltage pro The voltage pro The voltage pro The voltage pro The voltage pro The voltage pro probe The voltage pro probe The voltage pro standby volt p The voltage pro probe The voltage pro be type is a 3 3 V probe be type is a 5 V probe be type is a 5 V probe be type is a 12 V probe be type is a 12 V probe be type is an I O volt be type is a core volt be type is a FLEA robe be type is a battery volt be type is a SCSI termination volt probe The voltage pro The voltage pro be type is a 2 5 V probe be type is a ground termination logic GT
482. tal Data Bus Width Name memoryDeviceTotalDataBusWidth Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 17 Description Defines the total number of data bits used by the memory device Syntax DellUnsigned32BitRange Access Read only Device Group 269 Memory Device Correctable Memory Event Count K NOTE Memory Device Failure Modes has now replaced this attribute Memory Device Correctable Memory Event Count should no longer be used If you use the Memory Device Correctable Memory Event Count attribute the value returned is always zero and using the attribute will have no effect Name memoryDeviceSingleBitErrorCount Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 18 Description Defines the total number of Correctable Memory Events detected by the memory device Syntax DellSigned32BitRange Access Read only Memory Device Uncorrectable Memory Event Count K NOTE Memory Device Failure Modes has now replaced this attribute Memory Device Uncorrectable Memory Event Count should no longer be used If you use the Memory Device Uncorrectable Memory Event Count attribute the value returned is always zero and using the attribute will have no effect Name memoryDeviceMultiBitErrorCount Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 19 Description Defines the total number of Uncorrectable Memory Events detected by the memory device Syntax DellSigned32BitRange Access Read only 270 Device Group Memory Device Failure Modes
483. tary memory The system slot is an I O riser card The system slot is a NuBus The system slot is a PCI66MHz The system slot is an Advanced Graphics Port AGP The system slot is an AGP 2x card The system slot is an AGP 4x card Slot Group 321 Table 14 3 System Slot Type continued Variable Name De11SystemSlotType Data Type Integer Possible Data Values Meaning of Data Value systemSlotIsPCc98C20 18 The system slot is a PC 98 C20 systemSlotIsPc98Cc24 19 The system slot is a PC 98 C24 systemSlotIsPC98E 20 The system slot type is PC 98 E systemSlotIsPC98LocalBus 21 The system slot type is a PC 98 local bus systemSlotIsPCc98Card 22 The system slot type is a PC 98 card systemSlotIsPCIxX 23 The system slot type is a PCIX card systemSlotIsPCIExpress 24 The system slot type is a PCI Express card systemSlotIsAGP8x 25 The system slot type is an AGP 8x card Table 14 4 System Slot Usage Variable Name De1 1SystemSlotUsage Data Type Integer Possible Data Values Meaning of Data Value systemSlotUsageIsOther 1 The system slot usage is not one of following systemS1lotUsageIsUnknown 2 The system slot usage is unknown systemSlotUsageIsAvailable 3 The system slot is available systemSlotUsageIsInUse 4 The system slot is in use 322 Slot Group Table 14 5 System Slot Length Variable Name De1 1SystemSlotLength Data Type Integer Possible Da
484. tate Settings Name Object ID Description Syntax Access amperageProbeStateSettings 1 3 6 1 4 1 674 10892 1 600 30 1 4 Defines the state and settings of the amperage probe DellStateSettings Read write Amperage Probe Status Name amperageProbeStatus Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 5 Description Defines the status of the amperage probe Syntax DellSigned32BitRange Access Read only Amperage Probe Reading Name amperage ProbeReading Object ID 1 3 6 1 4 1 674 10892 1 600 30 1 6 Description Defines the reading for an amperage probe of type other than amperageProbelypelsDiscrete When the value for amperageProbe Type is amperageProbe lypelsPowerSupplyAmps or amperageProbelypelsSystemAmps the value returned for this attribute is the power usage that the probe is reading in tenths of Amperes When the value for amperageProbe Type is amperageProbe lypelsPowerSupply Watts or amperageProbelypelsSystem Watts the value returned for this attribute is the power usage that the probe is reading in Watts 154 Power Group Name amperageProbeReading When the value for amperageProbeType is other than amperageProbeTypelsDiscrete amperageProbe lypelsPowerSupplyAmps amperageProbe lypelsPowerSupply Watts amperageProbeTypelsSystemAmps or amperageProbe lypelsSystemWatts the value returned for this attribute is the amperage that the probe is reading in Milliamps When the value for amperageProbe Type is ampe
485. tatus Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 6 Description Defines the status of the BMC LAN interface Syntax DellStatus Access Read only BMC LAN Interface Channel Number Name bmcLANInterfaceChannelNumber Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 7 Description Defines the BMC channel number of the BMC LAN interface Syntax DellUnsigned8BitRange Access Read only BMC LAN Interface IP Address Source Name bmcLANInterfaceIPAddressSource Object ID 1 3 6 1 4 1 674 10892 1 1900 30 1 8 Description Defines the source type of the IP address of the BMC LAN interface Syntax DellBMCLANIPAddressSourceType Access Read only 496 Baseboard Management Controller Group BMC LAN Interface IP Address Name Object ID Description Syntax Access bmcLANInterfacelIPAddress 1 3 6 1 4 1 674 10892 1 1900 30 1 9 Defines the IP address of the BMC LAN interface IpAddress Read only BMC LAN Interface Subnet Mask Address Name Object ID Description Syntax Access bmcLANInterfaceSubnetMaskAddress 1 3 6 1 4 1 674 10892 1 1900 30 1 10 Defines the subnet mask of the BMC LAN interface IpAddress Read only BMC LAN Interface Default Gateway Address Name Object ID Description Syntax Access bmcLANInterfaceDefaultGatewayAddress 1 3 6 1 4 1 674 10892 1 1900 30 1 11 Defines the IP address of the default gateway for the BMC LAN interface IpAddress Read only BMC LAN Interface MAC Address Name Object ID
486. tax Access batteryNexusID 1 3 6 1 4 1 674 10893 1 20 130 15 1 9 Durable unique ID for this EMM DisplayString Read only Storage Management Group 599 Battery Predicted Capacity Access Name Object ID Description Syntax batteryPredictedCapacity 1 3 6 1 4 1 674 10893 1 20 130 15 1 10 Displays the battery s ability to be charged Possible values 1 Failed The battery cannot be charged and needs to be replaced 2 Ready The battery can be charged to full capacity 4 Unknown The battery is completing a Learn cycle The charge capacity of the battery cannot be determined until the Learn cycle is complete Integer Read only Battery Next Learn Time Syntax Access 600 Name Object ID Description batteryNextLearnTime 1 3 6 1 4 1 674 10893 1 20 130 15 1 11 Indicates the time in hours the next learn cycle must be executed Integer Read only Storage Management Group Battery Learn State Name Object ID Description Syntax Access batteryLearnState 1 3 6 1 4 1 674 10893 1 20 130 15 1 12 Specifies the learn state activity of the battery Possible values 1 Failed 2 Active 4 Timed out 8 Requested 16 Idle Integer Read only Battery Maximum Learn Delay Name Object ID Description Syntax Access batteryMaxLearnDelay 1 3 6 1 4 1 674 10893 1 20 130 15 1 14 The maximum amount of time in hours that the battery learn cycle can be delayed I
487. tax OCTET STRING SIZE 1 128 Access Read only 52 System State Group System State Temperature State Details Name Object ID Description Syntax Access systemStateTemperatureStateDetails 1 3 6 1 4 1 674 10892 1 200 10 1 23 Defines the state of all temperature probes in this chassis The results are returned as a binary octet string Each byte of the octet string represents the state of a specific temperature probe The first byte returned represents the state of the first temperature probe the second byte returned represents the status of the second temperature probe and so on The bytes have the same definition type as DellStateSettings OCTET STRING SIZE 1 128 Read only System State Temperature Status Combined Name Object ID Description Syntax Access systemStateTemperatureStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 24 Defines the status of all temperature probes in this chassis The result is returned as a combined status value The value has the same definition type as DellStatus DellStatus Read only System State Temperature Status Details Name Object ID Description Syntax Access systemStateTemperatureStatusDetails 1 3 6 1 4 1 674 10892 1 200 10 1 25 Defines the status of all temperature probes in this chassis The first byte returned represents the status of the first temperature probe the second byte returned represents the status of the second temperature probe
488. tch Status Combined Name systemStateACPowerSwitchStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 46 Description Defines the combined status of all AC power switches of this chassis Syntax DellStatus Access Read only 60 System State Group System State AC Power Switch Status List Name Object ID Description Syntax Access systemStateACPowerSwitchStatusList 1 3 6 1 4 1 674 10892 1 200 10 1 47 Lists the status of each AC power switch of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of an AC power switch The first byte returned represents the status of the first AC power switch and so on The bytes have the same definition type as DellStatus OCTET STRING SIZE 1 128 Read only System State Redundant Memory Unit Status Combined Name Object ID Description Syntax Access systemStateRedundantMemoryUnitStatusCombined 1 3 6 1 4 1 674 10892 1 200 10 1 48 Defines the combined status of all redundant memory units of this chassis DellStatus Read only System State Redundant Memory Unit Status List Name Object ID Description Syntax Access systemStateRedundantMemoryUnitStatusList 1 3 6 1 4 1 674 10892 1 200 10 1 49 Lists the status of each redundant memory unit of this chassis The results are returned as a binary octet string where each byte of the octet string represents the status of a redundant me
489. te Dial Up Modem Dial Type Variable Name De1 1RemoteDialUpModemDialType Data Type Integer Possible Data Values Meaning of Data Value remoteDialUpIsOther 1 The remote dial type is not one of the following remot eDialUpIsUnknown 2 The remote dial type is unknown remoteDialUpIsTone 3 remoteDialUpIsPulse 4 The remote dial type is tone The remote dial type is pulse 478 Remote Access Group Table 19 25 Remote User Dial In State Capabilities Variable Name De1 1RemoteUserDialInStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 unknownCapabilities 1 enableCapable 2 notReadyCapable 4 dialiInCallbackPresetNumber Capable 8 dialInCallbackUserSpecified Capable 16 The dial in user has no state capabilities The dial in user state capabilities are unknown The dial in user can be disabled or enabled The dial in user can be in the not ready state The dial in user can support callback using a preset number The dial in user can support callback using a user specified number Table 19 26 Remote User Dial In State Settings Variable Name Del 1RemoteUserDialInStateSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 unknown 1 enabled 2 notReady 4 dialInCallbackPresetNumber Enabled 8 dialInCallbackUserSpecified Enabled 16 The dial in
490. te for maintenance on this system DellDateName Read write Cost of Ownership Group 417 COO Maintenance End Date Name Name cooMaintenanceEndDat eName Object ID 1 3 6 1 4 1 674 10892 1 1600 80 1 5 Description Defines the end date for maintenance on this system Syntax DellDateName Access Read write COO Maintenance Provider Name Name cooMaintenanceProviderName Object ID 1 3 6 1 4 1 674 10892 1 1600 80 1 6 Description Defines the maintenance provider s name Syntax DellStateSettings Access Read write COO Maintenance Restrictions Name Name cooMaintenanceRestrictionsName Object ID 1 3 6 1 4 1 674 10892 1 1600 80 1 7 Description Defines the maintenance agreement restrictions Syntax DellCostofOwnershipString Access Read write COO Repair Table Name cooRepairTable Object ID 1 3 6 1 4 1 674 10892 1 1600 90 Description Defines the COO Repair Table Syntax SEQUENCE OF CooRepairTableEntry Access Not accessible 418 Cost of Ownership Group COO Repair Table Entry Name Object ID Description Syntax Access Index cooRepairTableEntry 1 3 6 1 4 1 674 10892 1 1600 90 1 Defines the COO Repair Table entry CooRepairTableEntry Not accessible cooRepairchassisIndex cooRepairlndex COO Repair Chassis Index Name cooRepairchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1600 90 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only COO Repair Index Na
491. tem has stopped responding Data Type Integer Possible Data Values Meaning of Data Value automaticRebootEnabled 1 Automatic reboot is enabled for this host automaticPowerCycleEnabled 2 Automatic power cycleable is enabled for this host automaticNotificationEnabled 4 Automatic notification is enabled for this host automat icPowerOf fEnabled 8 Automatic power off is enabled for this host Chassis Information Group 107 Table 5 15 Watchdog Timer Capabilities Variable Name De1 LWat chDogTimerCapabilities Data Type Integer Possible Data Values Meaning of Data Value typelCapable 1 Watchdog timer can time in intervals from 20 480 seconds type2Capable 2 Watchdog timer can time in 30 60 120 and 480 second intervals type3Capable 4 Watchdog timer can time in 60 second intervals Table 5 16 Power Button Control Capabilities Variable Name Del 1 PowerButtonControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The power button has no capabilities unknownCapabilities 1 The power button capabilities are unknown enableCapable 2 The power button can be enabled online or disabled offline Table 5 17 Power Button Control Settings Variable Name De11PowerButtonControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The power button has no settings capabilities unknown 1
492. tery sensor detected Critical A battery sensor in the a failure value Sensor Location lt Location in chassis gt Chassis Location lt Name of chassis gt Previous state was lt State gt Battery sensor status lt status gt specified system detected that a battery has failed The sensor location chassis location previous state and battery sensor status are provided RAC Traps This section describes the traps that are generated by the SNMP agent of the Remote Access Controller RAC All of the enterprise specific traps documented in this section belong to the MIB enterprise identified by OID 1 3 6 1 4 1 674 10892 2 and are sent with all of the trap variables documented in the section Traps The trap variables are sent in the order in which they are listed Table 25 17 Generic Traps Trap Name Description Severity Category Cause Supported ID by RAC Platform 0 CodeStart SNMP agent Information Status RAC power All Authentic is initializing itself invalid community name Request Critical Error ation received Failure with an on or reset SNMP All request with an invalid community name Traps 661 Table 25 18 Enterprise specific Traps Trap Name Description Severity Category Cause Supported ID by RAC Platform 1001 alertDrscTest The RAC Information Status A test SNMP All TrapEvent generated trap a test generated by trap event a RAC in response to a user reque
493. tes Syntax DellUnsigned32BitRange Access Read only Operating System Memory Available Virtual Size Name operatingSystemMemoryAvailableVirtualSize Object ID 1 3 6 1 4 1 674 10892 1 400 20 1 10 Description Defines the available virtual memory size in bytes Syntax DellUnsigned32BitRange Access Read only 118 Operating System Group System Resource Group The Management Information Base MIB variables presented in this section enable you to track various attributes of your system resources This section includes System Resource Group Tables that track variables such as the owner ports system memory interrupts and direct memory access System Resource Group Tables The following MIB tables define objects for the System Resource Group System Resource Map Table System Resource Owner Table System Resource Input Output I O Port Table System Resource Memory Table System Resource Interrupt Table System Resource Direct Memory Access DMA Table System Resource Map Table Name systemResourceMapTable Object ID 1 3 6 1 4 1 674 10892 1 500 10 Description Defines the System Resource Map Table Syntax SEQUENCE OF SystemResourceMap TableEntry Access Not accessible System Resource Group 119 System Resource Map Table Entry Name Object ID Description Syntax Access Index System Resource Name Object ID Description Syntax Access System Resource Name Object ID Description Syntax Access System R
494. that support NA Server Administrator services 25 Traps describes in band traps defined in the Server 5000 Administrator Instrumentation MIB and out of band traps sent by the Remote Access Controller RAC and Baseboard Management Controller BMC Appendix A Standard Data Type Definitions defines standard data NA types used in this reference guide AppendixB SNMP Sample Output provides a sample SNMP output NA Glossary Defines acronyms abbreviations and technical terms used NA in this reference guide Introduction 17 Server Administrator Instrumentation MIB The Server Administrator Instrumentation MIB filename 10892 mib provides instrumentation data that allows you to monitor the health of a system with SNMP management applications It provides Information about the status of temperatures power supplies voltages currents fans and memory at key points in the system e Rapid access to detailed fault and performance information gathered by industry standard systems management agents e Version information for Basic Input Output System BIOS firmware and operating system e A detailed account of every cost of ownership COO detail about your system In addition traps are sent to report a change in status of the health of critical components The Server Administrator Instrumentation MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information
495. the backplane board system board or drive carrier in the specified system exceeded its warning threshold The sensor location chassis location previous state and temperature sensor value are provided A temperature sensor on the backplane board system board or drive carrier in the specified system exceeded its failure threshold The sensor location chassis location previous state and temperature sensor value are provided Traps 639 Table 25 3 Temperature Probe Traps continued Trap ID Description Severity Cause Temperature Probe Nonrecoverable 1055 Temperature sensor detected Error A temperature sensor a non recoverable value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Temperature sensor value in degrees Celsius lt Reading gt If sensor type is discrete Discrete temperature state lt State gt Cooling Device Traps on the backplane board system board or drive carrier in the specified system detected an error from which it cannot recover The sensor location chassis location previous state and temperature sensor value are provided Cooling device traps monitor how well a fan is functioning Table 25 4 Cooling Device Traps Trap ID Description Cooling Device Normal 1102 Fan sensor returned to a normal value Sensor location lt Location in chas
496. the index one based of the PCI device configuration in this chassis DellObjectRange Read only PCI Device Configuration Space State Capabilities Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 82 1 3 Defines the capabilities of the PCI device configuration DellStateCapabilities Read only PCI Device Configuration Space State Settings Name Object ID Description Syntax Access 282 pCIDeviceConfigurationSpaceStateSettings 1 3 6 1 4 1 674 10892 1 1100 82 1 4 Defines the state of the PCI device configuration DellStateSettings Read write Device Group PCI Device Configuration Space Status Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceStatus 1 3 6 1 4 1 674 10892 1 1100 82 1 5 Defines the status of the PCI device configuration DellStatus Read only PCI Device Index Reference Name Object ID Description Syntax Access pCIDeviceIndexReference 1 3 6 1 4 1 674 10892 1 1100 82 1 6 Defines the index number of PCI device that this configuration applies to DellObjectRange Read only PCI Device Configuration Space Bus Number Name Object ID Description Syntax Access pCIDeviceConfigurationSpaceBusNumber 1 3 6 1 4 1 674 10892 1 1100 82 1 7 Defines the bus number of the PCI device configuration in this chassis DellUnsigned32BitRange Read only PCI Device Configuration Space
497. the user password control Syntax DellStatus Access Read only BIOS Setup Control User Password Verify Name Name bSUCuserPasswordVerifyName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 34 Description Defines the setup BIOS name of the current user password Syntax DellString Access Read write BIOS Setup Control User Password New Password Name Name bSUCuserPasswordNewPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 35 Description Defines the setup BIOS name of the new user password To set a new user password a you must have successfully set the current user password immediately preceding this password change Syntax DellString Access Read write 358 BIOS Setup Control Group BIOS Setup Control TPM Security Control Capabilities Name Object ID Description Syntax Access bsuCtpmSecurityControlCapabilities 1 3 6 1 4 1 674 10892 1 1400 10 1 36 Defines the BIOS setup control capabilities of Trusted Platform Module TPM security DellTPMSecurityControlCapabilities Read only BIOS Setup Control TPM Security Control Setting Name Object ID Description Syntax Access bsuCtpmSecurityControlSetting 1 3 6 1 4 1 674 10892 1 1400 10 1 37 Defines the BIOS setup control setting of Trusted Platform Module TPM security DellTPMSecurityControlSetting Read only BIOS Setup Control TPM Security Control Status Name Object ID Description Syntax Access bsuCtpmSecurityControlStatus 1
498. the value for amperageProbeType is amperageProbelypelsDiscrete the value returned for this attribute is the discrete reading for the probe Syntax DellAmperageDiscreteReading See Table 8 9 Access Read only AC Power Switch Table Name aCPowerSwitchTable Object ID 1 3 6 1 4 1 674 10892 1 600 40 Description Defines the AC Power Switch Table Syntax SEQUENCE OF ACPowerSwitchTableEntry Access Not accessible AC Power Switch Table Entry Name Object ID Description Syntax Access Index aCPowerSwitchTableEntry 1 3 6 1 4 1 674 10892 1 600 40 1 Defines the AC Power Switch Table entry ACPowerSwitchTableEntry Not accessible aCPowerSwitchchassisIndex aCPowerSwitchIndex 158 Power Group AC Power Switch Chassis Index Name Object ID Description Syntax Access aCPowerSwitchChassisIndex 1 3 6 1 4 1 674 10892 1 600 40 1 1 Defines the index one based of the chassis containing this AC power switch DellObjectRange Read only AC Power Switch Index Name Object ID Description Syntax Access aCPowerSwitchIndex 1 3 6 1 4 1 674 10892 1 600 40 1 2 Defines the index one based of this AC power switch DellObjectRange Read only AC Power Switch Capabilities Name Object ID Description Syntax Access aCPowerSwitchCapabilities 1 3 6 1 4 1 674 10892 1 600 40 1 3 Defines the capabilities of this AC power switch DellACPowerSwitchCapabilities Read only AC Power Switch Settings Name O
499. thorityName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 8 Description Defines the name of the authorized person who signs for the system Syntax DellCostofOwnershipString Access Read write COO Original Machine Configuration Expensed Name cooOriginalMachineConfigurationExpensed Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 9 Description Specifies whether the purchase of this system was expensed Syntax DellBoolean Access Read write C00 Original Machine Configuration Vendor Name Name cooOriginalMachineConfigurationVendorName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 10 Description Defines the vendor name of the system Syntax DellCostofOwnershipString Access Read only COO Cost Center Information Vendor Name Name cooCostCenterInformationVendorName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 11 Description Defines the cost center name of the system Syntax DellCostofOwnershipString Access Read write 396 Cost of Ownership Group COO User Information User Name Name Object ID Description Syntax Access cooUserInformat ionUserName 1 3 6 1 4 1 674 10892 1 1600 10 1 12 Defines the name of the user for this system DellCostofOwnershipString Read write COO Extended Warranty Start Date Name Name Object ID Description Syntax Access cooExtendedWarrantyStartDateName 1 3 6 1 4 1 674 10892 1 1600 10 1 13 Defines the extended warranty start date for this system DellDateName Read write COO Extende
500. thorization for service DellCostofOwnershipString Read write COO Outsourcing Provider Fee Name Name Object ID Description Syntax Access cooOut sourcingProviderFeeName 1 3 6 1 4 1 674 10892 1 1600 10 1 26 Defines any additional outsourcing charge for service DellCostofOwnershipString Read write COO Outsourcing Provider Service Level Name Name Object ID Description Syntax Access 400 cooOut sourcingProviderServiceLevelName 1 3 6 1 4 1 674 10892 1 1600 10 1 27 Defines the service level agreement for the system DellCostofOwnershipString Read write Cost of Ownership Group COO Insurance Company Name Name cooInsuranceCompanyName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 28 Description Defines the name of the company that insures this system Syntax DellCostofOwnershipString Access Read write COO Box Asset Tag Name Name cooBoxAssetTagName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 29 Description Defines the name of the asset tag Syntax DellCostofOwnershipString Access Read write C00 Box System Name Name cooBoxSystemName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 30 Description Defines the name of the system Syntax DellCostofOwnershipString Access Read write COO Box Central Processing Unit CPU Serial Number Name Name cooBoxCPUSerialNumberName Object ID 1 3 6 1 4 1 674 10892 1 1600 10 1 31 Description Defines the name of the CPU serial number for the system Syntax DellCostofOwn
501. tion Identifies the amount in megabytes of the free space on the array disk If this size is 0 it is smaller than a megabyte Syntax Integer Access Read only Storage Management Group 555 Array Disk Free Space in Bytes Name arrayDiskFreeSpaceInBytes Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 20 Description Identifies the size in bytes of the free space on the array disk that is smaller than a megabyte This size plus the arrayDiskFreeSpaceInMB is the total amount of free space on the array disk Syntax Integer Access Read only Array Disk Bus Type Name arrayDiskBusType Object ID 1 3 6 1 4 1 674 10893 1 20 130 4 1 21 Description Identifies the bus type of the array disk Possible values 1 SCSI 2 IDE 3 Fibre Channel 4 SSA 6 USB 7 SATA 8 SAS Syntax Integer Access Read only 556 Storage Management Group Array Disk Spare State Name Object ID Description Syntax Access arrayDiskSpareState 1 3 6 1 4 1 674 10893 1 20 130 4 1 22 Identifies the status of the array disk as a spare Possible states 1 Disk is a member of a virtual disk 2 Disk is a member of a disk group 3 Disk is a global hot spare 4 Disk is a dedicated hot spare 5 Not a spare 99 Not applicable Integer Read only Array Disk Roll Up Status Name Object ID Description Syntax Access arrayDiskRollUpStatus 1 3 6 1 4 1 674 10893 1 20 130 4 1 23 Severity of the array disk state This is the combined
502. tions between array disks the virtual disk to which they belong and their associated logical disk For each object in the table its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found Virtual Disk Table This table describes available properties for each virtual disk on the managed system The following object sets up the Virtual Disk Table Name virtualDiskTable Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 Description Defines the virtual disk table Syntax SEQUENCE OF VirtualDiskEntry Access Not accessible 604 Storage Management Group Virtual Disk Entry Name virtualDiskEntry Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 Description Defines the virtual disk table entry Syntax VirtualDiskEntry Access Not accessible Index virtual DiskNumber Virtual Disk Number Name virtualDiskNumber Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 1 Description Identifies the instance number of the virtual disk entry Syntax Integer Access Read only Virtual Disk Name Name virtualDiskName Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 2 Description Identifies the virtual disk s label generated by Storage Management or entered by the user Syntax DisplayString Access Read only Virtual Device Disk Name Name virtualDiskDeviceName Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 3 Description Identifies the device name used by this vir
503. tofOwnershipString Access Read write COO Support Information Fix Type Name Name cooSupport InformationFixTypeName Object ID 1 3 6 1 4 1 674 10892 1 1600 100 1 7 Description Defines the method used to fix the problem Syntax DellCostofOwnershipString Access Read write COO Trouble Ticket Table The MIB objects in the Trouble Ticket Table enable you to track details of any trouble tickets that you open for your system Name cooTroubleTicketTable Object ID 1 3 6 1 4 1 674 10892 1 1600 110 Description Defines the COO Trouble Ticket Table Syntax SEQUENCE OF cooTroubleTicketTableEntry Access Not accessible 422 Cost of Ownership Group COO Trouble Ticket Table Entry Name Object ID Description Syntax Access Index cooTroubleTicketTableEntry 1 3 6 1 4 1 674 10892 1 1600 110 1 Defines the COO Trouble Ticket Table entry cooTroubleTicketTableEntry Not accessible coo TroubleTicketchassisIndex cooTroubleTicketIndex COO Trouble Ticket Chassis Index Name Object ID Description Syntax Access cooTroubleTicketchassisIndex 1 3 6 1 4 1 674 10892 1 1600 110 1 1 Defines the index one based of this chassis DellObjectRange Read only COO Trouble Ticket Index Name Object ID Description Syntax Access cooTroubleTicket Index 1 3 6 1 4 1 674 10892 1 1600 110 1 2 Defines the index one based of the system s trouble ticket information DellObjectRange Read only COO Trouble Ticket State Name
504. tor A monitor is said to be DPMS compliant when it is designed to enter a power management state after receiving the appropriate signal from a computer s video controller DRAC Abbreviation for Dell Remote Access Card 696 Glossary DRAM Acronym for dynamic random access memory A computer s RAM is usually made up entirely of DRAM chips Because DRAM chips cannot store an electrical charge indefinitely your computer continually refreshes each DRAM chip in the computer drive type number Your computer can recognize a number of specific hard drives Each is assigned a drive type number that is stored in NVRAM The hard drive s specified in your computer s System Setup program must match the actual drive s installed in the computer The System Setup program also allows you to specify physical parameters logical cylinders logical heads cylinder number and logical sectors per pack for drives not included in the table of drive types stored in NVRAM DTE Abbreviation for data terminal equipment Any device such asa computer system that can send data in digital form by means of a cable or communications line The DTE is connected to the cable or communications line through a data communications equipment DCE device such as a modem ECC Abbreviation for error checking and correction ECP Abbreviation for Extended Capabilities Port EDO Acronym for extended data output dynamic random access memory which is a type of
505. trol settings unknown 1 The SNMP trap destination control settings are unknown trapTestCapable 2 A SNMP trap test will be performed for the SNMP trap destination Table 19 22 Remote Dial Up State Capabilities Variable Name De1 LRemoteDialUpStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value 476 none 0 The dial up functionality has no state capabilities unknownCapabilities 1 The dial up functionality state capabilities are unknown enableCapable 2 The dial up functionality can be disabled or enabled Remote Access Group Table 19 22 Remote Dial Up State Capabilities continued Variable Name De1 1RemoteDialUpStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value notReadyCapable 4 dialInCapable 8 dialOutCapable 16 dialInDHCPCapable 32 The dial up functionality can be in the not ready state The dial up functionality can support the dial in feature The dial up functionality can support the dial out feature The dial up functionality can support using DHCP to obtain an IP address for the dial in feature dialInAuthAnyCapable 64 The dial up functionality can support any authentication type including clear text for the dial in feature dialInAuthEncryptedCapable 128 The dial up functionality can support encrypted passwords CHAP authentication for the dial in feature dia
506. trolCapabilities See Table 5 5 Read only Chassis LED Control Settings Unique Name Object ID Description Syntax Access chassisLEDControlSettingsUnique 1 3 6 1 4 1 674 10892 1 300 10 1 25 Defines the readings and settings of the LED control hardware in the chassis DellLEDControlSettings See Table 5 6 Read write Chassis Hard Drive HD Fault Clear Control Capabilities Name Object ID Description Syntax Access chassisHDFaultClearControlCapabilities 1 3 6 1 4 1 674 10892 1 300 10 1 26 Specifies whether the chassis allows reset of the chassis hard drive fault LED DellHDFaultLEDControlCapabilities See Table 5 7 Read only Chassis HD Fault Clear Control Settings Name Object ID Description Syntax Access chassisHDFaultClearControlSettings 1 3 6 1 4 1 674 10892 1 300 10 1 27 Allows reset of the chassis hard drive fault LED DellHDFaultLEDControlSettings See Table 5 8 Read write 72 Chassis Information Group Chassis Identify Flash Control Capabilities Name chassisIdentifyFlashControlCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 28 Description Specifies whether the chassis front panel LED can be set to flash Syntax DellChassisIdentifyControlCapabilities See Table 5 9 Access Read only Chassis Identify Flash Control Settings Name chassisIdentifyFlashControlSettings Object ID 1 3 6 1 4 1 674 10892 1 300 10 1 29 Description Causes the chassis front pan
507. trolCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 3 Description Defines the capabilities of the serial port Syntax DellSerialPortControlCapabilitiesUnique See Table 16 15 Access Read only Serial Port Control Settings Unique Name serialPortControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 4 Description Defines the settings of the serial port Syntax DellSerialPortControlSettingsUnique See Table 16 16 Access Read only BIOS Setup Control Group 365 Serial Port Control Status Name serialPortControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 5 Description Defines the status of the serial port Syntax DellStatus Access Read only Serial Port Control Name Name serialPortControlName Object ID 1 3 6 1 4 1 674 10892 1 1400 40 1 6 Description Defines the setup BIOS name of the serial port Syntax DellString Access Read only USB Control Table These objects enable you to track the attributes of your Universal Serial Bus USB Name usbControlTable Object ID 1 3 6 1 4 1 674 10892 1 1400 50 Description Defines the USB Table Syntax UsbControlTableEntry Access Not accessible USB Control Table Entry Name usbControlTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1400 50 1 Description Defines the USB Table entry Syntax UsbControlTableEntry Access Not accessible Index usbControlchassisIndex usbControllndex 366 BIOS Setup Control Group USB Control Chassis Index Name us
508. tted the receiver can detect some types of transmission errors 694 Glossary cursor A marker such as a block underscore or pointer that represents the position at which the next keyboard or mouse action will occur DAT Acronym for digital audio tape dB Abbreviation for decibel s dBA Abbreviation for adjusted decibel s DC Abbreviation for direct current device driver A program that allows the operating system or some other program to interface correctly with a peripheral device such as a printer Some device drivers such as network drivers must be loaded from the config sys file with a device statement or as memory resident programs usually from the autoexec bat file Others such as video drivers must load when you start the program for which they were designed DIMM Acronym for dual in line memory module A small circuit board containing DRAM chips that connects to the system board DIN Acronym for Deutsche Industrie Norm which is the standards setting organization for Germany A DIN connector is a connector that conforms to one of the many standards defined by DIN DIN connectors are used widely in personal computers For example the keyboard connector for PCs is a DIN connector DIP Acronym for dual in line package A circuit board such as a system board or expansion card may contain DIP switches for configuring the circuit board DIP switches are always toggle switches with an ON p
509. tual disk s member disks Syntax DisplayString Access Read only Storage Management Group 605 Virtual Disk State Name virtualDiskState Object ID 1 3 6 1 4 1 674 10893 1 20 140 1 1 4 Description Identifies the current state of this virtual disk Possible states 0 Unknown 1 Ready The disk is accessible and has no known problems 2 Failed The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online 3 Online 4 Offline The disk is not accessible The disk may be corrupted or intermittently unavailable 6 Degraded The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online 15 Resynching 16 Regenerating 24 Rebuilding 26 Formatting 32 Reconstructing 35 Initializing 36 Background Initialization 38 Resynching Paused 52 Permanently Degraded 54 Degraded Redundancy Syntax Integer Access Read only 606 Storage Management Group Virtual Disk Severity Name Object ID Description Syntax Access virtualDiskSeverity 1 3 6 1 4 1 674 10893 1 20 140 1 1 5 This entry is obsolete for Storage Management It was replaced with RollUpStatus and ComponentStatus for each device Integer Read only Virtual Disk Length in Megabytes Name Object ID Description Syntax Access virtualDiskLengthInMB 1 3 6 1 4 1 674 10893 1 20 140 1 1 6 Identifies the size of this virtual disk in mega
510. tus and warning information for power cords that are part of an AC power switch if your system supports AC switching Table 25 12 AC Power Cord Traps Trap ID Description Severity Cause AC Power Cord No Power Nonredundant 1501 AC power cord is not being monitored Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt AC Power Cord Normal 1502 AC power has been restored Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt AC Power Cord Failure 1504 AC power has been lost Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Information Information Error The AC power cord status is not being monitored This occurs when a system s expected AC power configuration is set to nonredundant The sensor location and chassis location information are provided An AC power cord that did not have AC power has had the power restored The sensor location and chassis location information are provided An AC power cord has lost its power The sensor location and chassis location information are provided Traps 655 Hardware Log Traps Hardware logs provide hardware status messages to systems management software On certain systems the hardware log is implemented as a circular queue When the log becomes full the oldest status messages are overwritten when new status messages
511. ultLEDControlSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The LEDs do not have any fault settings capabilities unknown 1 The hard drive fault LEDs state is unknown enabled 2 The hard drive fault LEDs state is disabled offline a binary 0 value or enabled online a binary 1 value notReady 4 The hard drive fault LEDs state is not ready reset 8 The hard drive fault LEDs have been reset resetAndEnable 10 The hard drive fault LEDs have been reset and enabled Chassis Information Group 103 Table 5 9 Chassis Identification Control Capabilities Variable Name De 1 1ChassisIdentifyControlCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 The LEDs do not have any chassis identification capabilities unknownCapabilities 1 The chassis identification control s capabilities are unknown enableCapable 2 The chassis identification controls can be disabled offline a binary 0 value or enabled online a binary 1 value notReadyCapable 4 The chassis identification control s capabilities are not ready identifyCapable 8 The chassis identification control s LEDs can be made to identify the chassis NOTE Chassis identification capabilities allow system administrators to set front panel light emitting diodes LEDs to blink when the chassis has malfunctioning components When enabled the blinking lights he
512. undant memory feature is supported 346 Memory Group Table 15 6 Physical Memory Configuration Redundant Settings Variable Name DellPhysicalMemoryConfigRedundantSettings Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero There are no redundant memory settings enabled unknown 1 Redundant settings are unknown The following redundant settings are mutually exclusive spareEnabled 2 Spare redundant memory feature is enabled mirrorEnabled 4 Mirror redundant memory feature is enabled raidEnabled 8 RAID redundant memory feature is enabled Table 15 7 Physical Memory Logging Capabilities Variable Name De 11 PhysicalMemoryLoggingCapabilities Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero There are no logging capabilities unknown Capabilities 1 Logging capabilities are unknown The logging capabilities are enableCapable 2 Logging enable disable using Simple Network Management Protocol SNMP is supported MemoryGroup__ 347 Table 15 8 Physical Memory Logging Settings Variable Name De 11 PhysicalMemoryLoggingSettings Data Type Integer Possible Data Values Meaning of Data Value If set to 0 zero There are no logging settings enabled unknown Capabilities 1 Logging capabilities are unknown The logging settings are enabled 2 Logging is disabled 0 or enabled 1 348 Memory Group BIO
513. up System State AC Power Cord State Details Name systemStateACPowerCordStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 35 Description Defines the individual state of all AC power cords for any AC power switches in this chassis The first byte returned represents the state of the first AC power cord the second byte returned represents the state of the second AC power cord and so on Syntax OCTET STRING SIZE 1 128 Access Read only System State AC Power Cord Status Combined Name systemStateACPowerCordStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 36 Description Defines the overall status of all AC power cords for any AC power switches in this chassis Syntax DellStatus Access Read only System State AC Power Cord Status Details Name systemStateACPowerCordStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 37 Description Defines the individual status of all AC power cords for any AC power switches in this chassis The first byte returned represents the status of the first AC power cord the second byte returned represents the status of the second AC power cord and so on Syntax OCTET STRING SIZE 1 128 Access Read only System State Group 57 System State Redundant Memory Unit State Details Name systemStateRedundantMemoryUnitStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 38 Description Defines the state of all redundant memory units in this chassis The results are returned
514. up Control Administrator Password Verify Name Name bsuCadministratorPasswordVerifyName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 29 Description Defines the setup BIOS name for the current administrator password Syntax DellString Access Read write BIOS Setup Control Administrator Password New Password Name Name bSUCadministratorPasswordNewPasswordName Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 30 Description Defines the setup BIOS name of the new administrator password To set a new administrator password you must have successfully set the current administrator password immediately preceding this password change Syntax DellString Access Read write BIOS Setup Control User Password Control Capabilities Unique Name bsUCuserPasswordControlCapabilitiesUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 31 Description Defines the capabilities of user password control Syntax DellBIOSPasswordControlCapabilitiesUnique Access Read only BIOS Setup Control Group 357 BIOS Setup Control User Password Control Settings Unique Name bsUCuserPasswordControlSettingsUnique Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 32 Description Defines the control settings for user password control Syntax DellBIOSPasswordControlSettingsUnique See Table 16 9 Access Read write BIOS Setup Control User Password Control Status Name bSUCuserPasswordControlStatus Object ID 1 3 6 1 4 1 674 10892 1 1400 10 1 33 Description Defines the status of
515. urface that holds the circuits The rest of it is just a base CIM Acronym for Common Information Model which is a model for describing management information from the DMTF CIM is implementation independent allowing different management applications to collect the required data from a variety of sources CIM includes schemas for systems networks applications and devices and new schemas will be added It provides mapping techniques for interchange of CIM data with MIB data from SNMP agents and MIF data from DMI compliant systems CIMOM Acronym for common information model object manager cl O Acronym for comprehensive input output CMOS Acronym for complementary metal oxide semiconductor In computers CMOS memory chips are often used for NVRAM storage COMa The device names for the first through fourth serial ports on your computer are COMI1 COM2 COM3 and COM4 The default interrupt for COM and COM3 is IRO4 and the default interrupt for COM2 and COM4 is IRQ3 Therefore you must be careful when configuring software that runs a serial device so that you don t create an interrupt conflict component As they relate to DMI manageable components are operating systems computer systems expansion cards or peripherals that are compatible with DMI Each component is made up of groups and attributes that are defined as relevant to that component Glossary 693 config sys file The config sys file is executed when you
516. user has no state settings The dial in user state settings are unknown The dial in user is enabled The dial in user is in the not ready state Callback using a preset number is enabled for the dial in user Callback using a user specified number is enabled for the dial in user Remote Access Group __ 479 Table 19 27 Remote Dial Out State Capabilities Variable Name De 1RemoteDialOutStateCapabilities Data Type Integer Possible Data Values Meaning of Data Value none 0 unknownCapabilities 1 enableCapable 2 notReadyCapable 4 dialOut PPPAuthAnyCapable 8 dialOut PPPAuthEncryptedCapable 16 dialOut PPPAuthMschapCapable 32 The dial out destination has no state capabilities The dial out destination state capabilities are unknown The dial out destination can be disabled or enabled The dial out destination can be in the not ready state he dial out destination can support any authentication type including clear text for PPP The dial out destination can support encrypted passwords authentication type for PPP The dial out destination can support MSCHAP authentication type for PPP 480 Remote Access Group Table 19 28 Remote Dial Out State Settings Variable Name De 1RemoteDialOutStateSettings Data Type Integer Possible Data Values Meaning of Data Value none 0 The dial out destination has no state setting
517. userSecurityControlName Object ID 1 3 6 1 4 1 674 10892 1 800 1 4 Description Defines a control name used for creating deleting and editing users Syntax DellSecurityString Access Read write 200 User Security Group User Security Request Name Name userSecurityRequestName Object ID 1 3 6 1 4 1 674 10892 1 800 1 5 Description Defines a request name used for creating deleting and editing users Syntax DellSecurityString Access Read write User Security Group 201 202 User Security Group Remote Flash BIOS Group The Remote Flash Basic Input Output System BIOS Table defines the variables used to remotely update the BIOS in a system The variables also define the capabilities of BIOS updates on the system Remote Flash BIOS Group Table The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table Remote Flash BIOS Table The following object sets up the Remote Flash BIOS Table Name remoteFlashBIOSTable Object ID 1 3 6 1 4 1 674 10892 1 900 10 Description Defines the Remote Flash BIOS Table Syntax RemoteFlashBIOSTableEntry Access Not accessible Remote Flash BIOS Table Entry Name remoteFlashBIOSTableEntry Object ID 1 3 6 1 4 1 674 10892 1 900 10 1 Description Defines the Remote Flash BIOS Table entry Syntax RemoteFlashBIOSTableEntry Access Not accessible Index remoteFlashBIOSchassisIndex remoteFlashBIOSIndex Remote Flash BIOS Group 203 Remote Flash BIOS Chassi
518. ute defines the speed of the memory device in string format with units specified in string DellString Read only Memory Device Mapped Address Table Name Object ID Description Syntax Access memoryDeviceMappedAddressTable 1 3 6 1 4 1 674 10892 1 1100 60 Defines the Memory Device Mapped Address Table SEQUENCE OF MemoryDeviceMappedAddressTableEntry Not accessible Memory Device Mapped Address Table Entry Name Object ID Description Syntax Access Index 272 memoryDeviceMappedAddressTableEntry 1 3 6 1 4 1 674 10892 1 1100 60 1 Defines the Memory Device Mapped Address Table entry MemoryDeviceMappedAddress TableEntry Not accessible memoryDeviceMappedAddresschassisIndex memoryDeviceMappedAddressIndex Device Group Memory Device Mapped Address Chassis Index Name memoryDeviceMappedAddresschassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 60 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only Memory Device Mapped Address Index Name memoryDeviceMappedAddressIndex Object ID 1 3 6 1 4 1 674 10892 1 1100 60 1 2 Description Defines the index one based of the memory device mapped address in this chassis Syntax DellObjectRange Access Read only Memory Device Mapped Address State Capabilities Name memoryDeviceMappedAddressStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1100 60 1 3 Description Defines the capabilities of the memory device
519. vable module for portable computers standardized by PCMCIA PC Cards are also known as PCMCIA cards PC Cards are 16 bit devices that are used to attach modems network adapters sound cards radio transceivers solid state disks and hard disks to a portable computer The PC Card is a plug and play device which is configured automatically by the Card Services software Glossary 709 PCI Abbreviation for Peripheral Component Interconnect A standard for local bus implementation developed by Intel Corporation PCIX Abbreviation for PCI extended PCMCIA Personal Computer Memory Card International Association An international trade association that has developed standards for devices such as modems and external hard drives that can be plugged into portable computers PERC Acronym for PowerEdge Expandable RAID controller peripheral device An internal or external device such as a printer a disk drive or a keyboard connected to a computer PGA Abbreviation for pin grid array a type of microprocessor socket that allows you to remove the microprocessor chip physical memory array The physical memory array is the entire physical memory of a system Variables for physical memory array include maximum size total number of memory slots on the motherboard and total number of slots in use physical memory array mapped The physical memory array mapped refers to the way physical memory is divided For example one mappe
520. value in seconds for this remote access dial up functionality Syntax DellUnsigned32BitRange Access Read write 458 Remote Access Group Remote Dial Up Dial Out Modem Connect Time out Name remoteDialUpDialOutModemConnect Timeout Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 10 Description Defines the modem dial out time out value in seconds for this remote access dial up functionality Syntax DellUnsigned32BitRange Access Read write Remote Dial Up Modem Dial Type Name remoteDialUpModemDialType Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 11 Description Defines the dial type for the modem used by this remote access dial up functionality Syntax DellRemoteDialUpModemDialType SeeTable 19 24 Access Read write Remote Dial Up Modem Init String Name Name remoteDialUpModemInitStringName Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 12 Description Defines the initialization string to be sent to the modem for this remote access dial up functionality Syntax DisplayString SIZE 0 63 Access Read write Remote Dial Up Modem Baud Rate Name remoteDialUpModemBaudRate Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 13 Description Defines the baud rate for the modem used by this remote access dial up functionality Syntax DellUnsigned32BitRange Access Read write Remote Access Group 459 Remote Dial Up Modem Port Name remoteDialUpModemPort Object ID 1 3 6 1 4 1 674 10892 1 1700 40 1 14 Description Defines the port fo
521. value on the backplane Sensor location board system board Shoestion 1n ehesstes or drive carrier in the specified system Chassis location returned to a valid lt Name of chassis gt range after crossing a Previous state was lt State gt failure threshold The sensor location If sensor type is not i chassis location discrete previous state and Temperature sensor value in temperature sensor degrees Celsius lt Reading gt value are provided If sensor type is discrete Discrete temperature state lt State gt 638 Traps Table 25 3 Temperature Probe Traps continued Trap ID Description Severity Cause Temperature Probe Warning 1053 Temperature sensor detected Warning a warning value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Temperature sensor value in degrees Celsius lt Reading gt If sensor type is discrete Discrete temperature state lt State gt Temperature Probe Failure 1054 Temperature sensor detected Error a failure value Sensor location lt Location in chassis gt Chassis location lt Name of chassis gt Previous state was lt State gt If sensor type is not discrete Temperature sensor value in degrees Celsius lt Reading gt If sensor type is discrete Discrete temperature state lt State gt A temperature sensor on
522. x Access intrusionTable 1 3 6 1 4 1 674 10892 1 300 70 Defines the Intrusion Table SEQUENCE OF IntrusionTableEntry Not accessible Intrusion Table Entry Name Object ID Description Syntax Access Index intrusionTableEntry 1 3 6 1 4 1 674 10892 1 300 70 1 Defines the Intrusion Table entry Intrusion TableEntry Not accessible intrusionchassisIndex intrusionIndex Intrusion Chassis Index Name Object ID Description Syntax Access intrusionchassisIndex 1 3 6 1 4 1 674 10892 1 300 70 1 1 Defines the index one based of this chassis DellObjectRange Read only Chassis Information Group 93 Intrusion Index Name intrusionIndex Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 2 Description Defines the index of the intrusion objects in this subgroup Syntax DellObjectRange Access Read only Intrusion State Capabilities Name intrusionStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 3 Description Defines the capabilities of the intrusion object Syntax DellStateCapabilities Access Read only Intrusion State Settings Name intrusionStateSettings Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 4 Description Defines the settings of the intrusion object Syntax DellStateSettings Access Read write Intrusion Status Name intrusionStatus Object ID 1 3 6 1 4 1 674 10892 1 300 70 1 5 Description Defines the status of the intrusion object Syntax DellStatus Access Read only 94 Chassis
523. x Access memoryDeviceTypeDetails 1 3 6 1 4 1 674 10892 1 1100 50 1 11 Defines the detailed type of the memory device DellMemoryDeviceTypeDetails See Table 13 17 Read only Memory Device Form Factor Name Object ID Description Syntax Access memoryDeviceFormFactor 1 3 6 1 4 1 674 10892 1 1100 50 1 12 Defines the form factor of the memory device DellMemoryDeviceFormFactor See Table 13 15 Read only Memory Device Set Name Object ID Description Syntax Access 268 memoryDeviceSet 1 3 6 1 4 1 674 10892 1 1100 50 1 13 Defines if the memory device is a part of a set A zero 0 indicates that this device is not part of a set DellUnsigned32BitRange Read only Device Group Memory Device Size Name memoryDeviceSize Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 14 Description Defines the size in KB of the memory device Syntax DellUnsigned32BitRange Access Read only Memory Device Speed Name memoryDeviceSpeed Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 15 Description Defines the speed in nanoseconds of the memory device A zero 0 indicates that the speed is unknown Syntax DellUnsigned32BitRange Access Read only Memory Device Total Bus Width Name memoryDeviceTotalBusWidth Object ID 1 3 6 1 4 1 674 10892 1 1100 50 1 16 Description Defines the total number of bits including ECC used by the memory device Syntax DellUnsigned32BitRange Access Read only Memory Device To
524. x Access systemResourceOwnerStateSettings 1 3 6 1 4 1 674 10892 1 500 20 1 4 Defines the state settings of this system resource owner DellStateSettings Read write System Resource Owner Status Name Object ID Description Syntax Access systemResourceOwnerStatus 1 3 6 1 4 1 674 10892 1 500 20 1 5 Defines the status of this system resource owner DellStatus Read write System Resource Owner Interface Type Name Object ID Description Syntax Access systemResourceOwnerInterfaceType 1 3 6 1 4 1 674 10892 1 500 20 1 6 Defines the interface type for this system resource owner DellResourceOwnerInterfaceype See Table 7 2 Read only System Resource Map Index Reference Name Object ID Description Syntax Access systemResourceMapIndexReference 1 3 6 1 4 1 674 10892 1 500 20 1 7 Defines the index to the associated system resource map in this chassis DellObjectRange Read only System Resource Group 123 System Resource Owner Description Name Name systemResourceOwnerDescriptionName Object ID 1 3 6 1 4 1 674 10892 1 500 20 1 8 Description Defines the description name of the system resource owner Syntax DellString Access Read only System Resource Owner Interface Instance Name systemResourceOwnerInterfaceInstance Object ID 1 3 6 1 4 1 674 10892 1 500 20 1 9 Description Defines the associated system resource owner interface instance in this chassis Syntax DellObject
525. x physicalMemoryLoggingTableEntry 1 3 6 1 4 1 674 10892 1 1300 40 1 Defines the Physical Memory Logging Table entry PhysicalMemoryLogging TableEntry Not accessible physicalMemoryLoggingChassisIndex physicalMemoryLoggingIndex Physical Memory Logging Chassis Index Name Object ID Description Syntax Access physicalMemoryLoggingChassisIndex 1 3 6 1 4 1 674 10892 1 1300 40 1 1 Defines the index one based of the chassis associated with the physical memory logging DellObjectRange Read only Physical Memory Logging Index Name Object ID Description Syntax Access physicalMemoryLoggingIndex 1 3 6 1 4 1 674 10892 1 1300 40 1 2 Defines the index one based of the physical memory logging DellObjectRange Read only Physical Memory Logging Capabilities Name Object ID Description Syntax Access 336 physicalMemoryLoggingCapabilities 1 3 6 1 4 1 674 10892 1 1300 40 1 3 Defines the capabilities of the physical memory logging DellPhysicalMemoryLoggingCapabilities Read only Memory Group Physical Memory Logging Settings Name Object ID Description Syntax Access physicalMemoryLoggingSettings 1 3 6 1 4 1 674 10892 1 1300 40 1 4 Defines the settings of the physical memory logging DellPhysicalMemoryLoggingSettings Read write Physical Memory Logging Status Name Object ID Description Syntax Access physicalMemoryLoggingStatus 1 3 6 1 4 1 674 10892 1 1300 40 1 5 Defines t
526. x one based of the associated processor port in the same chassis DellObjectRange Read only Cache Device Table Name Object ID Description Syntax Access cacheDeviceTable 1 3 6 1 4 1 674 10892 1 1100 40 Defines the Cache Device Table SEQUENCE OF CacheDeviceTableEntry Not accessible Cache Device Table Entry Name Object ID Description Syntax Access Index cacheDeviceTableEntry 1 3 6 1 4 1 674 10892 1 1100 40 1 Defines the Cache Device Table entry CacheDeviceTableEntry Not accessible cacheDevicechassisIndex cacheDevicelndex Device Group 259 Cache Device Chassis Index Name Object ID Description Syntax Access cacheDevicechassisIndex 1 3 6 1 4 1 674 10892 1 1100 40 1 1 Defines the index one based of this chassis DellObjectRange Read only Cache Device Index Name Object ID Description Syntax Access cacheDeviceIndex 1 3 6 1 4 1 674 10892 1 1100 40 1 2 Defines the index of the cache device in this chassis DellObjectRange Read only Cache Device State Capabilities Name Object ID Description Syntax Access cacheDeviceStateCapabilities 1 3 6 1 4 1 674 10892 1 1100 40 1 3 Defines the capabilities of the cache device DellStateCapabilities Read only Cache Device State Settings Name Object ID Description Syntax Access 260 cacheDeviceStateSettings 1 3 6 1 4 1 674 10892 1 1100 40 1 4 Defines the state of the cache device DellStateSettings
527. x DellUnsigned32BitRange Access Read only 220 Port Group Memory Device Port Physical Memory Card Index Reference Name memoryDevicePort PhysicalMemoryCardIndexReference Object ID 1 3 6 1 4 1 674 10892 1 1000 40 1 11 Description Defines the index one based of the Physical Memory Card Table entry for the physical memory card with the same chassis index that this memory device port is associated with if any Syntax DellUnsigned32BitRange Access Read only Monitor Port Table Name monitorPortTable Object ID 1 3 6 1 4 1 674 10892 1 1000 50 Description Defines the Monitor Port Table Syntax IntegerMonitorPortTableEntry Access Not accessible Monitor Port Table Entry Name monitorPortTableEntry Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 Description Defines the Monitor Port Table entry Syntax MonitorPortTableEntry Access Not accessible Index monitorPortchassisIndex monitorPortIndex Monitor Port Chassis Index Name monitorPortchassisIndex Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 1 Description Defines the index one based of this chassis Syntax DellObjectRange Access Read only PortGroup 221 Monitor Port Index Name monitorPort Index Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 2 Description Defines the index of the monitor ports in this chassis Syntax DellObjectRange Access Read only Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1 3 6 1 4 1 674 10892 1 1000 50 1 3
528. xpanded Memory Specification EPP Abbreviation for Enhanced Parallel Port which provides improved bidirectional data transmission Many devices are designed to take advantage of the EPP standard especially devices such as network or SCSI adapters that connect to the parallel port of a portable computer EPROM Acronym for erasable programmable read only memory 698 Glossary ESD Abbreviation for electrostatic discharge ESM Abbreviation for Embedded Systems Management expanded memory A technique for accessing RAM above MB To enable expanded memory on your computer you must use an EMM You should configure your system to support expanded memory only if you run application programs that can use or require expanded memory expansion bus Your computer contains an expansion bus that allows the microprocessor to communicate with controllers for peripheral devices such as a network card or an internal modem expansion card connector A connector on the computer s system board or riser board for plugging in an expansion card extended memory RAM above 1 MB Most software that can use it such as the Windows operating system requires that extended memory be under the control of an XMM external cache memory A RAM cache using SRAM chips Because SRAM chips operate at several times the speed of DRAM chips the microprocessor can retrieve data and instructions faster from external cache memory than from RAM F Abbrev
529. y 162 Power Group AC Power Cord AC Power Switch Index Reference Name Object ID Description Syntax Access aCPowerCordaCPowerSwitchIndexReference 1 3 6 1 4 1 674 10892 1 600 42 1 6 Defines the index one based to the associated AC power switch for this AC power cord DellObjectRange Read only AC Power Cord Location Name Name Object ID Description Syntax Access Battery Table Name Object ID Description Syntax Access Battery Table Entry Name Object ID Description Syntax Access Index aCPowerCordLocationName 1 3 6 1 4 1 674 10892 1 600 42 1 7 Defines the location name of this AC power cord DellString Read only batteryTable 1 3 6 1 4 1 674 10892 1 600 50 Defines the Battery Table SEQUENCE OF Battery TableEntry Not accessible batteryTableEntry 1 3 6 1 4 1 674 10892 1 600 50 1 Defines the Battery Table Entry Battery TableEntry Not accessible batteryChassisIndex batteryIndex Power Group 163 Battery Chassis Index Name Object ID Description Syntax Access Battery Index Name Object ID Description Syntax Access batteryChassisIndex 1 3 6 1 4 1 674 10892 1 600 50 1 1 Defines the index one based of the chassis that contains the battery DellObjectRange Read only batteryIndex 1 3 6 1 4 1 674 10892 1 600 50 1 2 Defines the index one based of the battery DellObjectRange Read only Battery State Capabilities Name batteryStateCa
530. y redundant degraded 4 The object s redundancy has been degraded lost 5 The object s redundancy has been lost notRedundant 6 Redundancy does not apply or it is not redundant 680 Standard Data Type Definitions Table A 7 Dell Status Probe Variable Name De 1 1StatusProbe Data Type Integer Possible Data Values Meaning of Data Value other 1 The object s status is not one of the following unknown 2 The status of the object is unknown ok 3 The status of the object is OK nonCriticalUpper 4 The object is at the noncritical upper limit CriticalUpper 5 The object is at the critical upper limit nonRecoverableUpper 6 The object is at the nonrecoverable upper limit nonCriticalLower 7 The object is at the noncritical lower limit criticalLower 8 The object is at the critical lower limit nonRecoverableLower 9 The object is at the nonrecoverable lower limit failed 10 The status of the object is failed Dell Date Variable Name De11Date Data Type De lUnsigned 6 4BitRange OCTET STRING SIZE 8 The DellDate definition is required because SNMP V1 does not support 64 bit ranges The information sent back by this subagent will have the most significant byte of the information as the first byte For example the hex address 0x1029384754657687 will be sent as hex 0001 0000 0010 1001 0011 1000 0100 0111 Byte 1 Byte2 Byte3 Byte 4 Standard Data Type Definitions 681 Full
531. ying number e Description e Data type of the variable for example integer string octet string e Whether the variable is accessible not accessible read only or read write e Index or indexes if applicable For each MIB group that has unique variable definitions tables are included in the last section of the section to explain the meaning of the terms Standards for writing MIBs are defined by the Internet Engineering Task Force IETF Structure of Management Information SMI is a standard that specifies the rules for defining the structure and type of managed objects and events in a MIB SMIv1 is specified in Request For Comments RFC 1155 The Server Administrator MIB conforms to the SMIv1 standard SNMP is a systems management standard originally designed for network management SNMP manages much more than networks Information Technology IT professionals use SNMP for monitoring and managing computer systems and the various components and peripherals supported by their systems SNMP standards are defined by the Internet Engineering Task Force IETF SNMP version 1 was published in August 1988 and is the most commonly supported version of SNMP SNMP version 2 was first published in May 1993 but has not gained widespread market acceptance SNMP version 3 was recently completed and has addressed security issues that exist in version 1 All SNMP systems consist of one or more managed systems that provide data through an SNMP age
532. you turn off your computer NVRAM is used for maintaining the date time and system configuration information 708 Glossary OID Abbreviation for object identifier An implementation specific integer or pointer that uniquely identifies an object online access service A service that typically provides access to the Internet E mail bulletin boards chat rooms and file libraries OTP Abbreviation for one time programmable parallel port An I O port used most often to connect a parallel printer to your computer You can usually identify a parallel port on your computer by its 25 hole connector parameter A value or option that you specify to a program A parameter is sometimes called a switch or an argument partition You can divide a hard drive into multiple physical sections called partitions with the fdisk command Each partition can contain multiple logical drives After partitioning the hard drive you must format each logical drive with the format command PC 98 The third PC 9x specification which defines five categories Consumer Office Mobile Entertainment and Workstation It eliminates the ISA bus and pushes the minimum requirements to a 200MHz CPU with 32MB of RAM and 256K of L2 cache PC 98 machines must support OnNow and the BIOS must support booting from a CD and be Y2K compliant Systems cannot ship with ISA cards installed but may have an ISA bus for legacy devices PC card A credit card sized remo
533. ype Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 16 Description Indicates the type of the enclosure Possible values 1 Internal 2 Dell PowerVault 200S PowerVault 201S 3 Dell PowerVault 210S PowerVault 211S 4 Dell PowerVault 220S PowerVault 221S 5 6 7 8 Dell PowerVault 660F Dell PowerVault 224F Dell PowerVault 660F PowerVault 224F Dell MD1000 Syntax DisplayString Access Read only Enclosure Processor2 Version Name enclosureProcessor2Version Object ID 1 3 6 1 4 1 674 10893 1 20 130 3 1 17 Description This entry is obsolete for Storage Management Syntax DisplayString Access Read only 544 Storage Management Group Enclosure Configuration Name Object ID Description Syntax Access enclosureConfig 1 3 6 1 4 1 674 10893 1 20 130 3 1 18 Identifies the current configuration of the enclosure s backplane Possible values 1 Joined 2 Split Bus 3 Clustered 4 Unified Integer Read only Enclosure Channel Number Name Object ID Description Syntax Access enclosureChannelNumber 1 3 6 1 4 1 674 10893 1 20 130 3 1 19 Identifies the channel number or bus to which the enclosure is connected Integer Read only Enclosure Alarm Name Object ID Description Syntax Access enclosureAlarm 1 3 6 1 4 1 674 10893 1 20 130 3 1 20 Identifies the current status of the enclosure s alarm PowerVault 220S and PowerVault 221S only Possible values
534. ype as DellStatusRedundancy OCTET STRING SIZE 1 128 Read only System State Group 4 System State Power Supply State Details Name systemStatePowerSupplyStateDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 8 Description Defines the state of all power supplies in this chassis The results are returned as a binary octet string Each byte of the octet string represents the state of a specific power supply The first byte returned represents the state of the first power supply the second byte returned represents the state of the second power supply and so on The bytes have the same definition type as DellStateSettings Syntax OCTET STRING SIZE 1 128 Access Read only System State Power Supply Status Combined Name systemStatePowerSupplyStatusCombined Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 9 Description Defines the status of all power supplies in this chassis Syntax DellStatus Access Read only System State Power Supply Status Details Name systemStatePowerSupplyStatusDetails Object ID 1 3 6 1 4 1 674 10892 1 200 10 1 10 Description Defines the status of all power supplies in this chassis The results are returned as a binary octet string Each byte of the octet string represents the status of a specific power supply The first byte returned represents the status of the first power supply the second byte returned represents the status of the second power supply and so on The bytes have the same definition typ