Dacor Range ER48D User's Manual
Contents
1. 3 Cabinet countertop depth is at discretion of customer but CUT OUT DIMENSIONS cabinet face MUST NOT protrude further than rear of front panel see product dimensions Range Model SEX G H 4 Consult local code for exact location requirements i m m 5 Not applicable for cabinets more than a horizontal ER36D 42 1 067mm 36 1 1 6 33 1 2 distance of 10 254mm from the edge of the range 36 914mm 91 6mm 848mm a S ER48D 54 1372mm 48 1 16 43 1 2 Backsplash ee Gales 48 1219mm 1221mm 1102mm Minumum Countertop Height 1 A 30 1 4 768 mm aah i Recommended Maximum Countertop Height 1 hes 36 1 2 927 mm i Ze 1 Minimum 71 4 mm I 3 8 10mm 5 F Min flat countertop s Pr combustibl gt A EGA gemang a a 3 8 Min 10 mm rear wall recommended I flat countertop overhang t H i required behind cutout st Countertop l Lay I I j 7 4 hes E EE L EEE tea iD ry Stiffener ve th Cabinet face 10 254 mm Min 3 8 Min 10 mm L Lf Back of to combustible side Ea hening n CO control 3 raised vent ja it walls above the range chassis to clear i pang both sides stiffener ER36D or ER48D Range i i i it ERV36 ER or i y ERV48 ER i raised vent la Countertop height uw 30 1 4 768 mm Min I G gt 36 1 2 927 mm Max i il CUTOUT WITH OPTIONAL
2. ER36D ER48D cdacor Revised 03 10 09 Epicure Ranges PLANNING GUIDE The Life of the Kitchen lt 48 1219mm Front of Open Door He 30 3 4 781mm Front of Handle me 29 3 8 746mm gt Front Edge of Bullnose me 28 1 4 718mm gt Front Panel lt 26 1 8 664mm Rear of Front Panel Oven Door le 2 24 610mm 61mm Backguard 9 229mm Backguard 1 9 16 qm 40mm Aj j 1 1 16 27mm to cooking gt ENT a ackguard surface top of grates from CT top of trim 37 940mm Finished Side to Panel 35 3 4 908mm Optional All tolerances 1 16 1 6mm unless otherwise stated ELECTRIC CIRCUIT REQUIREMENTS Total Connected Load Range Model Circuit Required 240 Vac 4 wire 60 Hz ER36D 30 Amp Min 40 Amp 6 5 kW 28 Amp Recommended 240 Vac 4 wire 60 Hz ER48D 50 Amp 10 0 kW 42 Amp 4 wire two 120 Vac hot L1 and L2 one neutral one ground GAS SUPPLY PRESSURE REQUIREMENTS Minimum Gas Supply Pressure 6 Water Column Gas Type Manifold Pressure 5 Water Column 10 Water Column Natural Gas Propane LP 11 Water Column Maximum gas supply pressure 1 2 p s i for all models E Electrical Connection Width ER36D 35 7 8 911mm ER48D 47 7 8 1216mm Gas Regulator Access Co
3. ERV RAISED VENT i eal IE E ad etre ed ere ee ea 4 TOP VIEW oes ee eee Socios il Ul 7 APPROVED RAISED VENT MODELS IMPORTANT See CUTOUT WITH OPTIONAL ERV RAISED VENT For use with for countertop cutout dimensions Raised Vent Model IMPORTANT Cabinet face must not stick out further than Range Model back of control panel Enon Elven RAISED VENT INSTALLATION SIDE VIEW ERV48 ER ER48D Web http www Dacor com Specifications are subject to change without notice Corporate Phone 800 793 0093 See installation instructions for additional details 5 16
4. cal Service For replacement purposes the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range Check local building codes for permissible locations An external manual shut off valve must be installed between the gas inlet and the range for the purpose of turning on or shutting off gas to the appliance 13 330m Max mA The installation must allow for the following Access to the gas shut off valve when the unit is installed finished counter Non combustible surface along back wall recommended Z 30 762mm G 10 254mm Min Access to the remote circuit breaker panel fuse box when the 18 457mm UN Min we to combustible side ranae is in place t A walls above the range g p hothisides The gas supply piping and shut off valve and the electrical junction box receptacle must be located so they do not interfere with the range when it is installed Suggested location of utilities The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance 1 Vertical to combustibles directly above cooking surface remains connected if installing an overhead vent hood also check the hood specifications for minimum required clearances 2 Measured from range top panel
5. ver Removed d Range Electrical Access GAS ELECTRICAL ACCESS DIMENSIONS Cover Removed Model A B c D E ER36D 5 5 8 18 3 8 10 3 4 13 11 16 7 8 142 9mm 466 7mm 273 0mm 347 7mm 22 2mm Back of Range ER48D 3 13 16 18 11 16 9 3 8 13 3 4 1 1 8 96 8mm 474 7mm 238 1mm 349 3mm 28 6mm The diameter on models equipped for use in Canada is LY 6 4mm larger than those stated Canadian units come from a i the factory pre wired with an appliance cord When installing an i appliance cord on models that are not pre wired the hole size must A gt be increased to 1 1 8 1 3 8 for model ER48D by removing the conduit bracket inside the range electrical access box NOTES 1 When installing a backguard always install it before sliding the range into place Web http www Dacor com Corporate Phone 800 793 0093 Hole in Bottom o Observe all governing codes and ordinances during planning and installation Contact your local building department for further information gt This appliance must be installed in accordance with the accompanying installation instructions Specifications are subject to change without notice See installation instructions for additional details 5 15 ER36D ER48D gacor Revised Epicure Ranges siete The Life of the Kitchen 03 10 09 GUIDE Tolerances 1 16 0 1 6mm 0 unless otherwise stated Gas and Electri
Download Pdf Manuals
Related Search
Related Contents
Manual do módulo GVU20 M-Cab 7009028 speaker set Go2top - Club Alpin Suisse Relatório Final Samsung 460DRN User Manual MANUAL DE INSTRUCCIONES CAMPANA EXTRACTORA Owner`s manual & Installation manual Mode d`emploi et Directed Electronics Automate 552 User's Manual Baixar Manual Copyright © All rights reserved.