Home
Bryan Boilers CLM User's Manual
Contents
1. CLM Atmospheric Series Compliance Ultra Low NOx Water or Steam Boilers Air Assisted Gas Fired Sub 12 PPM Please delete these paragraphs from the standard CLM Series Boiler Sample Specification Form 2137 or 2138 GAS BURNER AND CONTROL EQUIPMENT The gas burner assembly shall be an integral part of the boiler Burners shall be tubular alloy steel atmospheric type for operation with natural draft requiring no motor or blower Gas pilot is to be electrically ignited The following trim and controls shall be furnished Pilot cock Electronic pilot ignition Gas pilot safety shutoff valve Honeywell Flame Safeguard RM7890A Main manual gas shutoff valve Electric gas valve operator and auxiliary safety shutoff gas valve CLM120 amp CLM150 7 Motorized gas valve operator and auxiliary safety shutoff gas valve CLM180 to CLM300 8 High gas pressure switch CLM270 to CLM300 9 Pilot and main gas pressure regulators DARN And substitute these paragraphs Ultra LOW NOX GAS BURNER AND CONTROL EQUIPMENT The Bryan Compliance boiler shall be furnished with a UL listed air assisted Ultra Low NOx Gas burner suitable for operation with natural gas Burner shall be complete with integral motor and blower for supplying sufficient combustion air with normal vent conditions Form 2367 gt Rev 04 21 06 Repl New 4 Burner must be Ultra Low NOx type for reduced emissions service Burner NOx r
2. eduction strategy shall reduce the production of NOx by controlling low excess air operation and reducing flame temperature Optimum stoichiometry shall be maintained by a fuel metering control with adjustments through the modulating range assuring NOx reduction and high fuel efficiency The special metal fiber burners are provided to assure the main flame is combusted properly on the burner head The natural gas firing NOx emissions will not exceed 12 ppm All emissions measurements are to be corrected to 3 On Control panel 16 x 20 includes Honeywell RMT840L Flame Safe Guard with UV scanner Supply voltage 240 480 3 60 and includes a control circuit air assisted transformer Natural gas pressure required 20 min 28 max The control will have a 5 to 1 turndown Sample Specification v Bryan Flexible Tube Boilers Page 1 of 1
Download Pdf Manuals
Related Search
Related Contents
TEFAL GV8700E0 Instruction Manual User Manual - Digital Connection Targus TSS236EU Nikon D80 Manual 説明書 - スリック VIEWIT USER GUIDELINES Partida Demorada depois da Partida Disparada 平成12年神審第61号 貨物船ぎおん丸運航阻害事件 言渡年月日 平成 MANUAL DE INSTALACIÓN Y OPERACIÓN Samsung CLX-3305 Цветное МФУ (18/4 стр/м) Инструкция по использованию Copyright © All rights reserved.
Failed to retrieve file