Home
Agilent Technologies Video Gaming Accessories 281 A User's Manual
Contents
1. 8 281A B Adapters Operating and Service Manual
2. iv 281A B Operating And Service Manual Assistance NO OTHER WARRANTY IS EXPRESSED OR IMPLIED AGILENT TECHNOLOGIES SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EXCLUSIVE REMEDIES THE REMEDIES PROVIDED HEREIN ARE BUYER S SOLE AND EXCLUSIVE REMEDIES AGILENT TECHNOLOGIES SHALL NOT BE LIABLE FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER BASED ON CONTRACT TORT OR ANY OTHER LEGAL THEORY YEAR 2000 Agilent Technologies warrants that each Agilent Technologies hardware software and firmware product on Agilent Technologies Corporate Price List dated July 1 1998 or later delivered under the product s contract of sale will be able to accurately process date data including but not limited to calculating comparing and sequencing from into and between the twentieth and twenty first centuries and the years 1999 and 2000 including leap year calculations when used in accordance with the product documentation provided that all other products that is hardware software firmware used in combination with such Agilent Technologies product s properly exchange date data with it If the agreement requires that specific Agilent Technologies products must perform as a system in accordance with the foregoing warranty then that warranty will apply to those Agilent Technologies products as a system and Customer retains sole responsibility to
3. 2 Agilent Technologies 281A B Adapters Operating and Service Manual Manual part number 00281 90045 Printed in USA Print Date May 2001 Supersedes October 2000 Notice The information contained in this document is subject to change without notice Agilent Technologies makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material Agilent Technologies assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Agilent Technologies This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without prior written consent of Agilent Technologies RESTRICTED RIGHTS LEGEND Use duplication or disclosure by the U S Government is subject to restrictions as set forth in subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 for DOD agencies and subparagraphs c 1 and c 2 of the Commercial Computer Software Restricted Rights clause at FAR 52 227 19 for other agencies Agilent Technologies Inc
4. 1 Wrap the adapter in heavy paper or plastic If shipping to a Agilent Technologies office or service center attach a tag indicating the type of service required return address and model number 2 Use a strong shipping container A double wall carton made of 350 pound test material is adequate 281A B Adapters Operating and Service Manual 3 Inspection and Shipping 3 Use enough shock absorbing material 3 to 4 inch layer around all sides of the adapter to provide firm cushion and prevent movement inside the container 4 Seal the shipping container securely 5 Mark the shipping container FRAGILE to assure careful handling 4 281A B Adapters Operating and Service Manual Protest Flanges Assemble Carefully Connector Types Figure 2 Operation Operation Care should be taken to protect the face of the flange from any damage that would prevent close surface to surface contact Any burring denting or scratching will increases RF leakage and the reflection coefficient of the joint The supplied plastic cover should be used to protect the flange when the adapter is not in use When connecting an adapter to a waveguide 1 Make sure the rectangular ports are oriented the same way i e not cross guided 2 Align ports carefully to minimize reflections 3 Clamp or bolt flanges securely together so that pressure is evenly distributed over the contacting surfaces Loose joints and flange distort
5. 81 426 56 7840 fax 61 3 9210 5947 Asia Call Center Numbers Country Phone Number Fax Number Singapore 1 800 375 8100 65 836 0252 Malaysia 1 800 828 848 1 800 801664 Philippines 632 8426802 632 8426809 1 800 16510170 PLDT Subscriber 1 800 16510288 PLDT Only Subscriber Only Thailand 088 226 008 outside Bangkok 66 1 661 3714 662 661 3999 within Bangkok Hong Kong 800 930 871 852 2506 9233 Taiwan 0800 047 866 886 2 25456723 People s Republic of 800 810 0189 preferred 10800 650 0121 China 10800 650 0021 India 1 600 11 2929 000 800 650 1101 vi 281A B Operating And Service Manual WARNING CAUTION Instrument Markings Safety and Regulatory Information Review this product and related documentation to familiarize yourself with safety markings and instructions before you operate the instrument This product has been designed and tested in accordance with international standards The WARNING notice denotes a hazard It calls attention to a procedure practice or the like that if not correctly performed or adhered to could result in personal injury Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met The CAUTION notice denotes a hazard It calls attention to an operating procedure practice or the like which if not correctly performed or adhered to could result in damage to the product or loss of important d
6. Electrical Check Claims Shipping Using Original Packaging Using Other Packaging Inspection and Shipping Inspection and Shipping If external damage to the shipping carton is evident the carrier s agent should be present when the adapter is unpacked Check the adapter for external damage If damage is evident refer to Claims below for recommended claim procedure If the shipping carton is not damaged check the packaging material for signs of stress that indicate rough handling in transit If the adapter appears undamaged perform the electrical check The electrical performance of the adapter should be checked as soon as possible after receipt against the specifications shown in Table 1 If the adapter does not perform within the specifications see the following paragraphs for recommended claim procedure and repackaging the instrument If physical damage is evident or if the adapter does not meet electrical specifications when received notify the carrier and the nearest Agilent Technologies office The same containers and material used in factory packaging can be obtained through Agilent offices If the adapter is being returned to Agilent Technologies for servicing attach a tag indicating the type of service required return address and model number Also mark the container FRAGILE to assure careful handling The following general instructions should be used for repackaging with commercially available materials
7. ensure the year 2000 readiness of its information technology and business environment The duration of this warranty extends through January 31 2001 The remedies available under this warranty will be defined in and subject to the terms and limitations of the warranties contained in the contract of sale To the extent permitted by local law this warranty applies only to branded Agilent Technologies products and not to products manufacture by others that may be sold or distributed by Agilent Technologies Nothing in this warranty will be construed to limit any rights or remedies provided elsewhere in the contract of sale with respect to matters other than year 2000 compliance Product maintenance agreements and other customer assistance agreements are available for Agilent Technologies products For assistance call your local Agilent Technologies Sales and Service Office refer to Service and Support on page vi 281A B Operating And Service Manual v Service and Support By internet phone or fax get assistance with all your test and measurement needs Online assistance www agilent com find assist United States Latin America Canada Europe tel 1 800 452 4844 tel 305 269 7500 tel 1 877 894 4414 tel 481 20 547 2323 fax 305 269 7599 fax 905 282 6495 fax 31 20 547 2390 New Zealand J apan Australia tel 0 800 738 378 tel 81 426 56 7832 tel 1 800 629 485 fax 64 4 495 8950 fax
8. 1400 Fountaingrove Parkway Santa Rosa CA 95403 1799 U S A Copyright 2000 2001 Agilent Technologies Inc ii 281A B Operating And Service Manual What You ll Find In This Manual Overview page 1 Specifications page 2 Inspection and Shipping page 3 Operation page 5 Replaceable Parts page 7 281A B Operating And Service Manual iii Certification Warranty Warranty Custom systems are warranted by contractual agreement between Agilent Technologies and the customer Agilent Technologies Inc certifies that this product met its published specifications at the time of shipment from the factory Agilent Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology NIST formerly NBS to the extent allowed by the Institute s calibration facility and to the calibration facilities of other International Standards Organization members This Agilent Technologies system product is warranted against defects in materials and workmanship for a period corresponding to the individual warranty periods of its component products Instruments are warranted for a period of one year During the warranty period Agilent Technologies will at its option either repair or replace products that prove to be defective Warranty service for products installed by Agilent Technologies and certain other products designated by Ag
9. ata Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met When you see this symbol on your instrument you should refer to the instrument s instruction manual for important information 4 This symbol indicates hazardous voltages NI The laser radiation symbol is marked on products that have a laser output This symbol indicates that the instrument requires alternating current ac input The CE mark is a registered trademark of the European Community If it is ccompanied by a year it indicates the year the design was proven o The CSA mark is a registered trademark of the Canadian Standards Association a ZA a 1SM1 A This text indicates that the instrument is an Industrial Scientific and Medical Group 1 Class A product CISPER 11 Clause 4 This symbol indicates that the power line switch is ON ls This symbol indicates that the power line switch is OFF or in STANDBY position 281A B Operating And Service Manual vii Safety Earth This is a Safety Class I product provided with a protective earthing Ground terminal An uninterruptible safety earth ground must be provided from the main power source to the product input wiring terminals power cord or supplied power cord set Whenever it is likely that the protection has been impaired the product must be made inoperative and secured against any unintended operation Before App
10. emale connectors and are available on the P281B P281B P281B X281A Option 13 281_adapt Figure 1 Adapters Showing Flange Types and Coaxial Connector Styles 281A B Adapters Operating and Service Manual 1 Specifications Specifications Table 1 281A B Specfications Model Frequency Fits Waveguide Size Equivalent Coaxial Length Weight Range GHz Nom OD in EIA Flange Connector in mm Ib kg X281A 8 20 to 12 40 1x12 WR90 UG135 U N female 1 7 16 37 1 4 0 1 P281B 12 40 to 18 00 0 702 0 391 WR62 UG419 U APC 73 1 26 3 16 0 1 1 Maximum Reflection Coefficient 0 11 1 25 SWR over entire frequency range 2 Typical maximum power handling capability for the Type N and APC 7 connectors is 200 W refer to caution below 3 Option 013 furnished with stainless steel Type N female connector Option 012 furnished with Type N male connector Option 006 adds additional alignment holes CAUTION The power that can be handled will be a function of the size of the center conductor The majority of the heat flow will be via conduction The weak point is the coax portion The waveguide portion is capable of higher power These numbers are assuming an ambient temperature of 25 degrees centigrade and an altitude of sea level Higher ambient temperatures and altitude would degrade power handling capability 2 281A B Adapters Operating and Service Manual Inspection Mechanical Check
11. ilent Technologies will be performed at Buyer s facility at no charge within Agilent Technologies service travel areas Outside Agilent Technologies service travel areas warranty service will be performed at Buyer s facility only upon Agilent Technologies prior agreement and Buyer shall pay Agilent Technologies round trip travel expenses In all other areas products must be returned to a service facility designated by Agilent Technologies For products returned to Agilent Technologies for warranty service Buyer shall prepay shipping charges to Agilent Technologies and Agilent Technologies shall pay shipping charges to return the product to Buyer However Buyer shall pay all shipping charges duties and taxes for products returned to Agilent Technologies from another country Agilent Technologies warrants that its software and firmware designated by Agilent Technologies for use with an instrument will execute its programming instructions when properly installed on that instrument Agilent Technologies does not warrant that the operation of the instrument or software or firmware will be uninterrupted or error free LIMITATION OF WARRANTY The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer Buyer supplied software or interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product or improper site preparation or maintenance
12. ion result in leakage and mismatch Type N Connectors Two versions of the Type N coaxial connector are used on the adapters one is used on the 281A model and the other is used in the Option 13B model The version on the 281A model is plated brass and is compatible with connectors conforming to MIL C 71 The version on the Option 13B model is stainless steel and is compatible with connectors conforming to MIL C 71 or MIL C 39012 Dimensions of these connectors are given in Figure 2 Dimensions of Type N Connectors 281A 281B A 0 316 min 0 316 min 0 320 max 0 320 max 0 204 min 0 207 max 0 188 min 0 206 max 0 063 min 0 066 max 0 066 max 281A B Adapters Operating and Service Manual 5 Performance Test Operation Precision 7 mm Connectors Except for Option 13 the 281B model adapter has a APC 7 precision 7 mm coaxial connector These connectors rely on uniform end to end contact of both conductors for electrical continuity Consequently the condition of the contacting surfaces is critical they should be kept clean and smooth To prevent damage when the adapter is not in use the connector s threaded sleeve should be fully extended The maximum SWR for the Adapters are listed in Table 1 When making these measurements the test results must be less than those listed in Table 1 plus the measurement uncertainty of the measurement system Measurement may be made using a standard reflectometer setu
13. lying Power Verify that the product is configured to match the available main power source as described in the input power configuration instructions in this manual If this product is to be powered by autotransformer make sure the common terminal is connected to the neutral grounded side of the ac power supply viii 281A B Operating And Service Manual Description Overview Agilent 281 adapters provide a convenient means of coupling between waveguide and coaxial systems Power can be transmitted in either direction and each adapter covers the full frequency range of its waveguide size with an SWR of less than 1 30 The flanges are lapped to a slight controlled convexity to assure minimum leakage at the waveguide joint A probe transforms the waveguide impedance to the 50 ohm impedance of coaxial line Complete specifications for the adapters are given in Table 1 Examples of the waveguide flange and coaxial connectors used on these adapters are shown in Figure 1 One type of flange and two types of coaxial connectors are used Type N female connectors which are compatible with connectors conforming to MILS 71 are available on all 281A adapters and Amphenol precision 7 mm connectors available on the 281B adapters The 7 mm connector features precise alignment a clearly defined reference plane and low RF leakage In addition any pair can be connected together without an adapter Option 13 adapters have stainless steel Type N f
14. p To ensure satisfactory performance make sure flanges and coaxial connectors are not damaged or worn 6 281A B Adapters Operating and Service Manual Replaceable Parts Replaceable Parts The 281A may be disassembled for part replacement but the 281B should be returned to Agilent because liquid nitrogen and special wrenches and gauges are needed for assembly The exploded view of Figure 3 gives information for ordering replacement parts and can be used as an assembly guide To obtain a replacement part give the adapter s full model number and the part number from Table 2 and address the order to the nearest Agilent Technologies office Figure 3 281A Replacement Parts en FILLISTER HEAD SCREW 3 StREWS i RF CONNECTOR BODY PROBE ASSEMBLY aR GASKET BRAID i j 8160 0074 i PROBE CASE tae WG BODY ASSEMBLY 281A B Adapters Operating and Service Manual 7 Replaceable Parts Table 2 281A Replaceable Parts Item No Description Model No Agilent Part No 1 RF Connector Body X281A 5020 0213 2 Probe Assembly X281A not applicable Probe Body 00281 20025 Probe Insulator 00281 20106 3 Probe Case X281A X281A 5 4 X band X281A 00281 20017 Flange Cap not shown X band X281A 5040 0354 P band P281B 5040 0358 1 This part is a subcomponent of item number 2 Probe Assembly for X281A NOTE All 281B adapters should be returned for part replacement
Download Pdf Manuals
Related Search
Related Contents
ウォームMA2015年5月 Bedienungsanleitung Modell 2001 Pulsoxymeter Bedienungsanleitung Dossier de presse Relatório Manual do Usuário InMax JA112 User Manual for BERI 保証書 - 株式会社ホーマーイオン研究所 Étude PREDICTIVE®: insulinothérapie en situation réelle à Copyright © All rights reserved.
Failed to retrieve file