1. Figure 4 Ifa door or window has been opened creating a draught then pilot disturbance could be the problem and removal of the draught should resolve this The appliance can then be re lit in accordance with the previous section If pilot disturbance is not the cause then the ODS safety system may be in operation Switch the appliance OFF call in your installer to check the appliance and ven tilation Remedial work must be carried out as required DO NOT allow the appliance to be used until the appliance and instal lation is passed as safe If the pilot continues to be extinguished you must call your installer to check the operation of the complete appliance 6 0 CLEANING Before carrying out any of the following operations ensure that the appliance is OFF and completely cold Regularly clean around the appliance to ensure that dust fluff pet hair etc are kept to a minimum There are no other specific requirements for care other than regular cleaning of the general appliance A wipe with a dry cloth is normally sufficient DO NOT use abrasive cleaners as they can damage the finish Metal parts may be cleaned using an appropriate metal cleaner Test on a hidden part before cleaning Clean only in the direction of the grain GLASS PANEL This can be cleaned with a suitable glass cleaner Test on a small area first PAINTED AREAS These can be cleaned using a dry cloth FINISHED METAL AREAS These can either be cleaned using
2. GB IE 4 2008 Smeg S p A dI Remove the outer packaging remove any instructions or fixing kits Read ALL these instructions before continuing to unpack or install this appliance Lift off the remaining packaging components and remove the contents of the box Check that the compo nents supplied correlate with the component checklist Please dispose of all the packaging materials at your local recycling centre QUANTITY DESCRIPTION Firebox and burner assembly Set of manufacturers instructions Decorative glass facia assembly Linear and Classic models Painted decorative facia in one of several colours Fab models Screw and wall plug pack Rubber grommet Fitting template All models There are four possible entry points for the gas supply pipework to enter the appliance firebox The L23 firebox is shown in figure 2 as an example but the relative locations of these holes are the same for all models These entry points are knock out type holes Non concealed gas con nections may be made using the entry points in the bottom or sides of the firebox A concealed gas connection may be made using the knock out hole in the centre back of the firebox Select the most appropriate entry point and knock out the relevant hole with a sharp tap from a ham mer and fit the rubber grommet supplied A small incision can now be made in the rubber to slip snugly around the outside of the supply pipe and sleeving All installati
3. Pressure Pressure Destination 1 5 mbar 0 75 mbar al fher ocea j He e Cold AT CH CZ HR ES Fl GB 17 18 7 74 GR IE IT NO SE SK TR ig aa cond lace 18 6123 5 74193 4 0 5 2 7 3 7 2 as ies ise 12 108 na ns oa 9 L30 MODELS High Burner Low Burner Pressure Pressure Destination 7 5 mbar ae 75 mbar Country Cod AT CH CZ HR ES Fl GB 260 235 150 135 137 136 43 GR IE IT NO SE SK TR DE PL a 260 235 150 135 CERS a eS See Pe a asr wt fs amo ais igo is es 7 s6 ss P23 MODELS L23 MODELS L30 MODELS Flow Restrictor Orifice 03mm 03mm 30mm Oxypilot Sit Bray 9114 9114 9114 Gas Control BM733 BM733 BM733 Gas Inlet Various Various Various Ignition Piezo Spark Piezo Spark Piezo Spark Spark Gap 1 0mm 4 0mm 4 0mm 4 0mm 3 0 INSTALLATION REQUIREMENTS If the appliance is to be sited near a disused or unserviceable fireplace served by a natural draught flue then the old flue must be sealed off It will be necessary to ventilate the old flue to prevent condensation and dampness forming however any air vent used to ventilate the old flue must not be sited within 500mm of this appliance If the flue can be ventilated to the outside of the build ing then this is usually the best solution If in doubt then advice should be sought from a local building control officer The appliance is designed to be wall mounted If the appliance is to be mounted on a newly fabricate
4. edition of BSEN 50291 must be installed in the same room as the appliance For maximum safety it is recommended that such device is continuously mains powered and arranged in such a way that the gas supply to the appliance is of the appliance into the wall isolated in the event of an alarm The selection and installation of such device shall be in accordance with the current edition of BSEN 50292 and the user must be briefed regarding the use and maintenance of such a device The appliance is designed to be versatile and as such will operate correctly when exposed to normal gentle draughts experienced within the home It is not recommended however that the appliance be installed in areas where it is likely to be directly exposed to persistent strong draughts that may be generated by outside doors windows air vents air conditioning units extractor fans ceiling fans etc See section 4 1 for more information on ventilation This appliance is designed to be wall hung Do not recess any part Clearances to non combustible materials Non combustible surfaces are defined as brick metal marble concrete etc and also a number of man made materials impervi ous to flame If in doubt refer to the material manufacturer for further information before proceeding with installation Clearances to the sides of the appliance are 100mm 4 Clearance to the front of the appliance is 500mm 20 The back of the appliance may be installed directly
5. flueless catalytic flame effect gas fire It provides radiant and convected warmth both effi ciently and safely utilising the latest type catalytic converter and burner technology e The appliance does not require a flue system of any type as the catalytic converter cleans the flue products to provide a com plete combustion system which is intrinsically safe It is designed to operate on Natural Gas and is factory set for operation on the gas type and at the pressure stated on the appliance data plate e The appliance incorporates a combustion monitoring system Oxygen Depletion System It must not be adjusted or put out of operation If replaced then manufacturer s original parts must be used e This appliance must be installed by a competent person to ensure that the size of the room in which the appliance is to be installed is sufficient and the ventilation provision for that room is sufficient for the appliance Details of how to determine the suitable room size is given in section 3 1 of these instructions and details of how to determine suitable ventilation are given in section 4 1 e In the event of gas leakage from the appliance the gas supply must be turned off at the nearest isolating valve e The appliance must be installed in accordance with the following e Manufacturers Instructions Outlet openings e Local Codes and or Regulations DONOTBLOCK f e Failure to comply with the above could lead to prosecution and deem the m
6. rear cover of booklet e The installation and Servicing of this fire MUST only be carried out by a competent person in accordance with local Codes and or Regulations Building Regulations and the manufacturer s instructions Failure to comply with the above could lead to prosecution and invalidate the appliance warranty In the event of gas leakage from the appliance the gas supply must be turned off at the nearest isolating valve This appliance is only suitable for the gas type for which it is supplied e Keep a note of the installer s name and address the original purchase receipt and the date of installation Failure to produce this information may invalidate the warranty The appliance should be serviced regularly to ensure continued safe operation See the servicing section for further reference o Figure e The guard glass front is to prevent risk of fire or injury from burns and no part of Outlet openings it should be permanently removed It Does Not Give Full Protection For Young DO NOT BLOCK Children Or The Infirm Parts of this appliance become naturally hot during use It is recommended that a suitable fireguard is used especially where young children pets the elderly or infirm are concerned The manufacturer of this appliance consid ers all surfaces as working surfaces with the exception of the control knob and con trol panel e Combustible items such as flooring and furniture and soft wall coverings such as blown vinyl or embos
7. the combustion ratio for the appliance CO CO2 it is first necessary to express both gas concentrations in terms of percentage To convert from parts per million ppm to a percentage divide the ppm figure by 10 000 Examples 35ppm 0 0035 5ppm 0 0015 5ppm 0 0005 Now divide the concentration of carbon monoxide CO expressed in percent by the concentration of carbon dioxide CO2 to obtain the appliance combustion ratio COC __ CO2 ratio The combustion ratio of the gasses emitted by the catalytic convertor should not exceed 0 0015 If replacing firstly remove the decorative frame glass facia as described in section 8 3 and outer casing The catalysts are locat ed on the top of the internal firebox and can be removed by unscrewing the retaining nuts securing the clamping plates Remove the catalysts their seals and discard Refit the new catalysts and seals in reverse order ensure the catalysts and the glass door have good seals Appliances that are several years old or have been extensively dismantled should be checked for soundness It is important that all the products of combustion pass through the catalytic converter at the top of the firebox before leaving the appliance The firebox is heated by lighting for a few minutes to provide a flow through the firebox The burner is then shut off and a smoke pellet or match introduced at the base of the fire underneath the burner tray Large quantities of smoke will emerge
8. the fire is cold using a damp cloth and mild detergent on most surfaces Advise that on first light up of a new appliance initial curing of high temperature paint and burning off of lubricants may occur for the first few hours of operation During this period some smoke may be emitted from the outlet grille this should be no cause for concern Accordingly the room should be well ventilated with all windows and doors open during this period During this period the appliance may cause smoke alarms to sound If this happens reset the alarms but do not remove the batteries Recommend that a guard be used for the protection of the young pets the elderly and the infirm Advise the customer that the ventilation openings should not be blocked or obstructed in any way Isolate the fire from the gas supply Ensure that the fire is fully cold before attempting service A suggested procedure for servicing is detailed below Lay out the dustsheet and tools Remove the decorative frame glass facia assembly Removal is reverse of section 8 3 Remove the glass door assembly 4 screws and clean carefully Inspect the burner and the catalyst and clean if necessary with a soft brush Disconnect the gas supply Detach the burner front cover plate by removal of the four retaining screws Undo the two screws retaining the burner support bracket to the base and rear of the firebox Remove the four screws retaining the valve bracket to the firebox Remo
9. INSTALLATION amp USER INSTRUCTIONS WALL MOUNTED HIGH EFFICIENCY GAS FIRE smeg MODELS COVERED BY THESE INSTRUCTIONS Gp technology with style P23 LINEAR _ P23 LIN SMEG S p A 42016 P23 CLASSIC i P23CL CE Guastalla RE L23 LINEAR L23LIN ITALY L23 CLASSIC L23CL L30 FAB L30FAB P23 Linear P23 Classic L23 Linear L23 Classic Please note Except where otherwise stated all rights including copyright in the text images and layout of this booklet is owned by Smeg S p A You are not permitted to copy or adapt any of the content without the prior written permission of Smeg S p A This product is tested and approved to EN 14829 2007 All instructions must be handed to the user for safekeeping GB IE 2008 Smeg S p A L30 Fab ap Section Contents Page No Section Contents Page No 1 0 Important Notes 2 8 0 Testing and Commissioning 6 2 0 Appliance Data 3 8 1 Operating the Appliance 7 3 0 Installation Requirements 3 8 2 Setting pressure 7 3 1 Room Sizing 3 8 3 Fitting the Decorative Frame 8 4 0 Site Requirements 4 9 0 Briefing the customer 8 4 1 Ventilation 4 10 0 Servicing 8 5 0 Unpacking the Appliance 5 10 1 Servicing the Burner Unit 9 5 1 Component Checklist 5 10 2 Pilot Assembly 9 6 0 Gas Supply Routes 5 10 3 Catalysts lO 7 0 Fixing the Appliance 6 10 4 Testing for Firebox Leakage 10 7 1 Checking the Burner amp Spark Gap 6 11 0 Troubleshooting Guide l I e This appliance is a high efficiency
10. a proprietory metal cleaner Test on a small hidden part before cleaning Always clean in the direction of the grain 2008 Smeg S p A 7 0 SERVICING ED The appliance should be checked on an annual basis to ensure it is working safely and that there is no excessive build up of soot The frequency of service will depend on usage but MUST be carried out at least once annually Servicing must be carried out by a competent person 8 0 LIST OF REPLACEMENT PARTS The Installation instructions carry full servicing details for the use of the installer PART NO ITEM F96000 Inner glass door assembly P23 models F960002 Inner glass door assembly L23 models F960003 Inner glass door assembly L30 models F730038 Pilot assembly FT003 155 2 Gas valve Please Enquire Burner unit F780079 Catalyst seal kit must also be supplied F940136 Seal kit for Catalyst 9 0 INSTALLATION DETAILS Model Supplied by Date installed Fire serial No Name amp contact details of installer 10 0 SERVICE HISTORY As our policy is one of continuous improvement and development we hope therefore you will understand we must retain the right to amend details and or specifications without prior notice 2008 Smeg S p A
11. able to maintain temperatures within limits P23 and L23 models The room size should be a minimum of 23m e g 3 07m x 3 07m x 2 45m or 10 I x 10 l x 8 L30 models The room size should be a minimum of 30m e g 3 5m x 3 5m x 2 45m or 1 1 6 x 11 6 x 8 This is to allow adequate circulation of air and ensure the correct operation of the fire This volume may include adjacent spaces but these spaces must not be separated by a door Note To calculate a room size in cubic metres m divide the room volume in cubic feet ft3 by 35 3 It should be noted that heaters create warm air currents These currents move heat to wall surfaces next to the heater Installing the heater next to vinyl or cloth wall coverings or operating the heater where impurities in the air such as tobacco smoke can dle smoke etc exist may cause the walls to become discoloured This appliance is intended as a secondary source of heat only and should not be used in a room without some form of back ground heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room GB IE 2 2008 Smeg S p A 4 0 OPERATING THE APPLIANCE GB IE Classic models The control knob is located on the lower right hand side of the outer case It is marked as shown in figure 2 Linear models The control knob is located on the lower right hand side of the outer case It is marke
12. anufac turer s warranty invalid e This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space The appliance is designed to fit various types of situa tions as described in sections 3 0 and 4 0 The appliance must be installed in a correct ly sized room see section 3 1 and the correct purpose provided ventilation must be provided see section 4 1 e On no account should the appliance inlet or outlet openings be blocked or obstruct ed in any way see figure Do not place objects on top of the appliance Do make sure the appliance is installed on a flat wall Inlet openings e It should be noted that heaters create warm air currents These currents move heat DO NOT BLOCK to wall surfaces next to the heater Installing the heater next to vinyl or cloth wall cov erings or operating the heater where impurities in the air such as tobacco smoke can dle smoke etc exist may cause the walls to become discoloured Note L30FAB shown from rear as example however the air inlet and outlet openings are in the same relative positions on all models e This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room e On first ligh
13. ar internally for proper operation NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT Modifications are dangerous and can have serious unseen effects on safety If the pilot will not stay lit there is a problem with dirt the gas supply to it or the thermocouple needs replacement The gas valve is a non serviceable item If this needs replacement remove M4 securing screw holding the valve in place remove all pipe unions electrode lead thermocouple lead and then the complete valve Replacement must be original manufacturers parts Re assembly is the reverse of removal Ensure setting pressures are as stated in Section 2 Appliance Data Remove the burner unit as detailed in section 10 1 then remove the lint arrestor and pilot unit by using a screwdriver to remove the retaining screws Clean the pilot assembly with a soft brush and blow through Check the aeration holes are free of any dirt or lint Clean thoroughly internally the connection can be removed from the base of the pilot unit using two spanners to make cleaning easier Do not damage or try to dismantle the pilot injector The unit is factory set and the only check necessary is to ensure the spark gap is correct See specifications for gap setting NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT f the pilot will not stay lit there is a problem with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can hav
14. bed in this section and insert the chosen type of wall fixings Insert the wall fixing screws into the top wall plugs taking care to leave the screws pro truding approximately 5mm from the wall Now hang the appliance onto these screws through the two keyhole shaped holes in the upper brack ets on the back panel of the appliance Insert the lower fixing screws into the lower wall plugs through the cor responding fixing holes in the lower part of the back panel Do not tight en fully Before tightening the wall mounting screws fully at this stage it is recom mended to check the horizontal alignment of the appliance with a spirit bers of the wall using two of the fixing screws provid _ 349mm 13 74 t 419mm 16 5 H THIS FIRE IS TO BE WALL HUNG ONLY DO NOT RECESS OR INSET ANY PART OF THE FIRE THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY DO NOT INSTALL THE FIRE WITH THIS TEMPLATE IN PLACE GAS MODEL L23G GAS MODEL L27G 405mm 15 94 326 5mm 12 85 FIREBOX OUTLINE CENTRE LINE MR E Dee ae Figure 4 Figure 5 level as small adjustments can still be made if necessary When this has been checked tighten all four fixing screws fully To access the upper fixing screws insert a screwdriver through the round access holes in the front face of the outlet grille as shown in figure 5 These access holes are located in the same position on all models There ar
15. case It is of a spher ical design and is marked as shown in figure 9 Figure 7 The pilot is visible behind the left hand side of the burner Push in and turn the control knob to the SPARK position and hold there for a few seconds Continue turning anti clockwise through the spark click to the PILOT light posi tion ensuring the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob pressed for approximately ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ignition procedure To achieve the HIGH setting push the control knob in slightly and continue turning anti clockwise to the high position The main burner should light after a few seconds To decrease the setting to low turn the control knob clockwise to the LOW setting To turn to the PILOT position from the HIGH or LOW positions press the control knob in and return to the pilot position and release To turn the fire off keep the knob pressed in return to the OFF position and release All models The pressure test point is located on the left hand side of the appliance on the main burner pipe next to the brass restrictor connector Remove the burner cover plate to access by removal of the four retaining screws as shown in fig ure l0 Release the setting pressure test point screw shown in figure 1 and attach a pr
16. d area of wall that also serves the purpose of sealing off the old flue then it is very important that there are no holes gaps or otherwise in this wall that will allow draughts from the old flue to enter the room especially directly behind the appliance Such draughts could affect the performance of the ODS sys tem and result in nuisance cutting out for example If the gas supply pipe is to enter the appliance from the rear i e emerge from the wall behind the appliance then any hole in the wall from which the pipe emerges must be tightly sealed 3 1 ROOM SIZING In the absence of any local Codes and or Regulations governing room sizing for type AIAS appliances then the information given here must be followed e P23 and L23 models The room size should be a minimum of 23m e g 3 07m x 3 07m x 2 45m or 10 I x 10 I x 8 e L30 models The room size should be a minimum of 30m e g 3 5m x 3 5m x 2 45m or 11 6 x I 1 6 x 8 This is to allow adequate circulation of air and ensure the correct operation of the fire This volume may include adjacent spaces but these spaces must not be separated by a door Note To calculate a room size in cubic metres m divide the room volume in cubic feet ft by 35 3 2008 Smeg S p A OB IE This appliance may be installed in any room in the home except bathrooms If the appli ance is to be fitted in a bedroom then an electronic carbon monoxide detector com plying with the current
17. d as shown in figure 3 Fab models The control knob is located on the lower right hand side of the outer case It is of a spher ical design and is marked as shown in figure 4 The pilot is visible behind the left hand side of the burner Push in and turn the control knob to the SPARK position and hold there for a few seconds Continue turning anti clockwise through the spark click to the PILOT light position ensuring the pilot has lit If not return the knob clockwise and repeat When the pilot lights after the spark keep the knob pressed for approximately ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ignition procedure LOW position To achieve the HIGH setting push the control knob in slightly and continue turning anti clockwise to the high position The main burner should light after a few seconds To decrease the setting to low turn the control knob clockwise to the LOW setting HIGH position To turn to the PILOT position from the HIGH or LOW positions press the control knob in and return to the pilot position and release To turn the fire off keep the knob pressed in return to the OFF position and release 5 0 COMBUSTION MONITORING SYSTEM This fire is fitted with a combustion monitoring safety device ODS If the appliance shuts down during use for no apparent rea son then several reasons may be suspected
18. e a serious unseen effect on safety and therefore MUST not be done Replacements must be original manufacturers parts Re assembly is the reverse of removal Ensure setting pressures are as stated in Section 2 Appliance Data GB IE 9 2008 Smeg S p A ap It is recommended that the catalysts are inspected for signs of damage and dirt during routine servicing procedures The expect ed life of the catalysts is in excess of 1 000 hours 10 years of normal use After this time the catalysts should be replaced If there are any deposits of dirt or soot on the catalyst they should be cleaned with a soft brush and a vacuum cleaner If removed for cleaning ensure the seals are in good condition before replacing the catalyst New seals will usually be required The performance of the catalysts may be checked using a combustion gas analyser as follows Any analyser used should conform to EN 50379 3 Ignite the fire as per the operating instructions and run at maximum setting for 15 minutes Position gas sample probe directly over the catalysts via the outlet grille on top of the appliance Record the carbon dioxide CO2 concentration and then the car bon monoxide CO concentration as displayed by the analyser also noting the units in which the values are expressed Most analysers display carbon dioxide CO2 concentrations in percentage terms and carbon monoxide concentration in parts per million ppm terms In order to calculate
19. e no imitation fuel bed components to install The appliance features a ribbon burner which is designed to produce a continuous band of flame over its length Spark gap The burner should be visually inspected to ensure it is free from any foreign matter If it is necessary to clean or dust off the burner then the glass door should be removed by removal of the four retaining screws Re fit the glass door after cleaning or inspection ensuring a good seal The gap between the spark electrode and the pilot should be 3 5mm to produce a good spark see figure 6 There should be no need to adjust this If under any circumstances the piezo electric Figure 6 spark fails the pilot cannot be lit manually oF E S The appliance is supplied with a selection of inlet adaptors for use in the various countries of destination Select an appropriate adaptor and connect to the flared inlet connection of the appliance Ensure the inlet adaptor connection is fully tightened Turn on and test the gas supply up to the fire for any leaks in accordance with local Codes and or Regulations GB IE 6 2008 Smeg S p A Classic models The control knob is located on the lower right hand side of the outer case It is marked as shown in figure 7 Linear models The control knob is located on the lower right hand side of the outer case It is marked as shown in figure 8 Fab models The control knob is located on the lower right hand side of the outer
20. e permitted directly above the appliance regardless of distance The minimum clearance to the ceiling above the appliance is 800mm 31 5 measured from the top of the appliance glass panel Combustible materials should not be positioned directly in front of the appliance within a distance of one metre Under no circumstances should any electrical equipment e g plasma LCD screen TV sets etc be positioned on the wall above the appliance The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire sur round No combustible shelves should be positioned on the wall above the appliance It should be established that any mirrors or picture frames etc to be positioned on the wall above the appliance are able to withstand prolonged exposure to moderate heat and moisture before proceeding with their installation The back of the appliance may be installed directly onto a combustible wall providing it is relatively flat and does not interfere with the various vent holes in the back panel of the appliance The wall must be structurally sound and constructed from a mate rial capable of withstanding moderate heat Brick concrete finished plaster most types of conventional wall paper and dry lined plasterboard are examples of suitable materials Materials such as flock blown vinyl and embossed paper which are sensitive to even small amounts of heat should be avoided as scorching and or discolouration may occur ov
21. e positioned on the wall above the appliance The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire sur round No combustible shelves should be positioned on the wall above the appliance It should be established that any mirrors or picture frames etc to be positioned on the wall above the appliance are able to withstand prolonged exposure to moderate heat and moisture before proceeding with their installation The back of the appliance may be installed directly onto a combustible wall providing it is relatively flat and does not interfere with the various vent holes in the back panel of the appliance The wall must be structurally sound and constructed from a mate rial capable of withstanding moderate heat Brick concrete finished plaster most types of conventional wall paper and dry lined plasterboard are examples of suitable materials Materials such as flock blown vinyl and embossed paper which are sensitive to even small amounts of heat should be avoided as scorching and or discolouration may occur over time If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the appliance must be confirmed It is important in these circumstances that any vapour control bar rier is not damaged and that any structural members of the house frame are not damaged refer to section 7 0 The appliance must
22. er time If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the appliance must be confirmed It is important in these circumstances that any vapour control bar rier is not damaged and that any structural members of the house frame are not damaged refer to section 7 0 of the installa tion section of these instructions The appliance must not be positioned vertically within 100 mm 4 of a carpeted floor rugs or fabric materials of any kind This dimension is measured vertically to the bottom of the appliance firebox Purpose provided ventilation of 100cm MUST be provided for this appliance An openable window or equivalent is also required Any ventilation fitted must comply with local Codes and or Regulations Ventilation fitted under or within immediate vicinity of the appliance must not be used as it may adversely effect performance of the combustion monitoring system ODS system The appliance shall not be installed within metre of any existing air vent and any new air vent shall not be installed within metre of the appliance Ventilation openings should never be blocked or restricted in any way The requirements of other appliances operating in the space or room must be taken into consideration when assessing ventila tion requirements this will have been carried out by your installer A supply of fresh air into the room is advis
23. essure gauge Light the fire on the HIGH setting To commission the appliance the burner pressure must be in accordance with the figures stated in section 2 0 of these instructions The fire is factory set to achieve these pressures and any significant variation could indicate a supply problem If the pressure is too high the gas supply meter may be set incor rectly This should be checked with the fire running and if nec essary reset by the gas supplier If the burner pressure is too low then check the inlet pressure with the appliance running If this is less than the inlet pressu stated in section 2 0 of these instructions it will need to be reset by the gas supplier If the setting pressure is too low but the meter pressure is acceptable then a problem in the supply pipework is to be suspected Upon satisfactory checking of the burner pressure turn the fire off disconnect the pressure gauge and refit the test point Figure screw Light the fire and check for gas soundness Re fit the burner cover plate and replace the four retaining screws Fab model shown as example Figure 8 OFF position SPARK position LOW position HIGH position Figure 9 L23 model shown as example In the event that the burner pressure is not in accordance with the figures stated in the data section of these instructions the appliance must not be commissioned and the manufact
24. from the top of the appliance but none should emerge from the joints or gasket faces especially around the door It is important to note that the appliance can never be expected to be 100 smoke tight and small quantities of smoke may be seen in corners of joints and gasket faces etc without affecting safety when the fire is in operation GB IE 10 2008 Smeg S p A Fire sparks but pilot does not light Pilot lights but then goes out Fire does not spark at pilot Fire runs for a time and then cuts off Pilot flame shrinks when fire is on high Fire smells when first lit or in use No gas to fire check isolators are open Pipe work blockage clean out Air not fully purged re purge supply or wait longer Spark earthing to metal work reset gap correctly Blocked pilot clean out internally Severe restriction in gas supply clear obstruction Faulty thermocouple replace pilot unit Blocked pilot clean out Blocked lint gauze clean Hold control knob in for longer Check control knob does not foul indicator plate If the pilot will not stay lit there is a problem with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT HT lead detached refit Check the spark gap see section 7 1 Faulty piezo unit replace Debris shorting out electrode clean Spark short
25. ing to metalwork under tray realign HT lead Loose or faulty thermocouple rectify Blocked pilot clean out Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit there is a problem with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT Poor gas flow to fire check pressure with fire on high If pressure is low remove any restriction in pipework or valve Check all isolators are adequately sized and fully open Check meter pressure is adequate If the pilot will not stay lit there is a problem with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT Newness smell from brand new appliance Leakage occurring Carry out leakage test and rectify any problems Combustible materials used in incorrect positions GB IE 1 2008 Smeg S p A Section Content Page No 0 Important Notes 2 0 Clearances to Combustibles 3 0 Ventilation amp Room Size 2 4 0 Operating Instructions 3 5 0 Combustion Monitoring System 3 6 0 Cleaning 3 7 0 Servicing 4 8 0 List of Replacement Parts 4 9 0 Installation Details 4 10 0 Service History 4 11 0 Appliance Dimensions Inside
26. not be positioned vertically within 100 mm 4 of a carpeted floor rugs or fabric materials of any kind This dimension is measured vertically to the bottom of the appliance firebox GB only A minimum of 100 cm purpose provided ventilation MUST be provided for this appliance This may be achieved either with one vent 100 cm at a high or low position in the room or split ventilation i e 50cm be installed at high level and 50cm be installed at low level within the room An openable window or equivalent is also required To reduce the possibility of draughts road noise or insects entering the room via the air vent we recommend the use an air vent of the type that feature internal baffles IE only Refer to the current edition of IS813 The requirements of any other gas oil or solid fuel appliances operating in the same room or space must be taken into consid eration when assessing ventilation Any ventilation fitted must comply with any relevant local codes for the installation of ventilation Ventilation fitted under or within immediate vicinity of the appliance must not be used as it may adversely effect performance of the ODS system The appliance shall not be installed within metre of any existing air vent and any new air vent shall not be installed within metre of the appliance Note With the appliance installed in the minimum size room and with the ventilation specified the concentration of NO2 in the room is less than 300ppb
27. on pipework must be in accordance with the current edition of National regulations codes and the rules in force In order to avoid unnecessary pressure drops use of small diameter pipe should be kept to a minimum for example we rec ommend no more than 5 metres of 8mm pipe If a concealed gas connection is to be made the supply pipe should always be sleeved through walls and floors using the shortest possible route For concealed supply pipe routing pipes must where possi ble be vertical and providing there is sufficient wall thickness available they should be placed in pipe chases Horizontal pipe runs should be avoided Prior to chasing a solid wall an inspection should be made to note the proximity of any cables sockets out lets which may already be buried Pipes must be secured using suitable clips and protected against corrosion Ideally factory fin ished protected pipework and fittings should be used Joints should be kept to a minimum and compression fittings must not be used The pipework installation must be tested for tightness before any protection is applied and or the pipework and fittings are buried Figure 2 Remove any protective film coatings from the finished decorative surfaces of the appliance After having selected the final mount ing position of the appliance taking into account the requirements as specified in sections 3 and 4 of these instructions the integrity of the wall and the feasibility of the proposed sup
28. oncrete etc and also a number of man made materials impervious to flame If in doubt refer to the material manufacturer for further information before proceeding with installation Clearances to the sides of the appliance are 100mm 4 Clearance to the front of the appliance is 500mm 20 The back of the appliance may be installed directly onto a non combustible wall providing the area behind the appliance is flat and does not interfere with the various vent holes in the back panel of the appliance A non combustible shelf of any depth may be positioned above the appliance provided it is no closer than 400mm 16 from the top of the appliance glass panel and the wall above the appliance is non combustible The appliance must not be positioned vertically within 60mm 2 4 of a solid floor i e wood or stone or hearth This dimen sion is measured vertically to the bottom of the appliance firebox GB IE 2008 Smeg S p A ap Clearances to combustible materials Combustible materials are defined as wood fabrics or other materials likely to combust if exposed to flame Generally any mate rial which is likely to discolour melt or misshape when exposed to moderate heat should be considered as a combustible mate rial or surface Clearance to the sides of the appliance are 100mm 4 but curtains drapes and other fabrics are not permitted within a dis tance of 500mm 20 of the appliance sides No such materials ar
29. onto a non combustible wall providing the area behind the appliance is flat and does not interfere with the various vent holes in the back panel of the appliance A non combustible shelf of any depth may be positioned above the appliance provided it is no closer than 400mm 16 from the top of the appliance glass panel and the wall above the appliance is non combustible The appliance must not be positioned vertically within 60mm 2 4 of a solid floor i e wood or stone or hearth This dimension is measured vertically to the bottom of the appliance firebox Clearances to combustible materials Combustible materials are defined as wood fabrics or other materials likely to combust if exposed to flame Generally any mate rial which is likely to discolour melt or misshape when exposed to moderate heat should be considered as a combustible mate rial or surface Clearance to the sides of the appliance are 100mm 4 but curtains drapes and other fabrics are not permitted within a distance of 500mm 20 of the appliance sides No such materials are permitted directly above the appliance regardless of distance The minimum clearance to the ceiling above the appliance is 800mm 31 5 measured from the top of the appliance glass panel Combustible materials should not be positioned directly in front of the appliance within a distance of one metre Under no circumstances should any electrical equipment e g plasma LCD screen TV sets etc b
30. ply pipe routing the firebox A WARNING of the appliance may be secured to the wall mum To ensure customer safety be sure to design the installation so that the strength of The wall where the appliance is o oe to be installed must be capable both the wall and any wall fixings used are sufficient of long term support of the total Smeg S p A assumes absolutely no responsibility for injuries and damages that may Coe Ke Me Ma automo Er CETTE occur due to improper installation or handling The appliance should not be installed Toue also be Sare to pares until all wet plastering and or dry wall sanding and wall painting has been completed Sucen ees n OVIN Do not block the ventilation holes of the appliance The wall onto which the appliance the force of earthquakes vibra Egi onana Rer eer Ga is installed must be flat Install only on a vertical surface Avoid sloped surfaces Installation onto anything other than a vertical wall may result in fire damage or injury If the appliance is to be mounted on the inner leaf of a conventional cavity brick wall or a solid wall then the wall plugs and fix ing screws provided may be used Depending on the condition of the wall it may be necessary to use additional fixings In this situation any additional fixings and wallplugs should be of the same size and type as the ones provided At the appropriate stage of the installation drill four holes using only a 8mm masonry bit to a depth of 42mm Insert the
31. sed paper low temperature surrounds etc may dis 7 colour if fitted too close to the fire See relevant section for further details on clear _ ances to combustibles No combustible materials or flooring should protrude onto the hearth if fitted e This appliance incorporates a combustion monitoring system ODS e DO NOT burn any foreign material on this fire Under no circumstances shall the appliance be used if the glass front door or panel has been removed damaged or is Leg open On no account should the appliance inlet or outlet openings be blocked or _ obstructed in any way see figure DO NOT place objects on top of the appliance Note L30FAB shown from rear as example however the air inlet and outlet openings are in the same relative positions on all models Inlet openings DO NOT BLOCK e WARNING Due to the nature of this product the area around the top of the appli ance i e the grille gets very hot Care should be taken when operating the appliance The integral catalysts should be checked by the installer upon servicing to ensure there are no defects or obstructions that may prevent the satisfactory flow of combustion products The expected life of the catalyst is in excess of 1 000 hours 10 years of normal use After this time the catalyst should be replaced Clearances to non combustibles Non combustible surfaces are defined as brick metal marble c
32. t up of a new appliance burning off of high temperature paint and lubricants may occur for the first few hours of operation During this period some smoke may be emitted from the outlet grille this should be no cause for concern Accordingly the room should be well ventilated with all windows and doors open during this period During this period the appliance may cause smoke alarms to sound If this happens reset the alarms but do not remove the batteries e WARNING Due to the nature of this product the area around the top of the appliance i e the grille gets very hot Care should be taken when operating the appliance The manufacturer of this appliance considers all surfaces as working surfaces with the exception of the control knob The guard glass front is to prevent risk of fire or injury from burns and no part of it should be permanently removed It Does Not Give Full Protection For Young Children Or The Infirm Where young children pets the elderly or infirm are concerned a suitable fireguard should be used e Consult ALL instructions before installation and use of this appliance This appliance is free from any asbestos material GB IE 2 2008 Smeg S p A 2 0 APPLIANCE DATA High Burner Low Burner Max Energy Input Min Energy Input Pressure Pressure 1 5 mbar 0 75 mbar 25 Gross Nee Gros Nee Hor com Hoe e e a wom laa o u w w m ua s iss 166 0 os m4 35 s3 s L23 MODELS High Burner Low Burner
33. urer should be contacted for guidance GB IE 7 2008 Smeg S p A Please note that the Linear and Classic models are supplied with a tinted glass facia assembly which dif fer in appearance when viewed from the front simi larly the Fab model is supplied with a metal facia however the method of attachment to the appliance for all frame designs is the same All models Remove the facia panel from any protec tive packaging Ensure all any protective film is removed as the facia may be damaged if the fire is lit with the facia in position whilst still covered in film The facia panel is sup N 2mm ported by four M6 screws which protrude hess from the front of the i l outer casing as shown in J a figure 12 Ensure each Figure 13 screw is unscrewed approximately one turn from the fully screwed in posi tion in order to create a 2mm gap as shown in figure 13 Simply hang the facia panel onto the outer casing ensuring that the corresponding keyhole shaped holes engage the screwheads fully Figure 2 All instructions must be handed to the user for safekeeping Show the customer how to light and control the fire After commissioning the appliance the customer should be instructed on the safe use of the appliance and the need for regular servicing Frequency of service depends on usage but MUST be carried out at least once annually Advise that cleaning of the fire may be achieved when
34. ve the control knob and spindle assembly from the valve by removal of the spindle retaining clip 7 Remove the burner unit strip off the burner pipes and clean thoroughly 8 Clean the in line restrictor pilot assembly and the burner tube Do not attempt to remove the pilot injector as this can cause damage 9 Re assemble components 10 Turn on the gas supply and leak test Check pilot and burner for good ignition I Refit the glass door assembly ensuring correct orientation and a good seal 2 Refit the decorative facia frame assembly as detailed in section 8 3 13 Check the purpose provided ventilation is un obstructed 4 Light the fire and test setting pressures OMB WDN I5 Check safe operation of the appliance For specific servicing instructions see relevant sections GB IE 8 2008 Smeg S p A All models Firstly remove the decorative frame glass facia assembly as described in section 8 3 Remove the inner glass panel and disconnect the gas connection inside appliance The gas con nections to the gas valve can now be released Detach the burner front cover plate by removal of the four retaining screws as shown in figure 10 sec tion 8 2 Remove the control knob and spindle assembly from the valve by removal of the spindle retaining clip Classic and Linear models To remove the outer casing sides and top remove the four retain ing screws designated a in figure 14 Pull the casing forward slightl
35. wallplugs provided ensuring they are flush to the wall GB IE 5 2008 Smeg S p A A WARNING If the appliance is to be mounted on a dry lined wall or igure a a timber framed construction wall then efforts should MEGTETT EOE O EE be made to fix in at least two positions vertically into S e Eo erant iA one of the wooden studs or supporting wooden mem It is not recommended to rely on plasterboard fixings alone to sup port the weight of the appliance ed If this is not achievable then the wall should be strength ened using appropriate building materials If there is no alternative than to rely on some plasterboard fixings then special cavity screw fixings or hollow wall anchors will be required which are not supplied with this product These should be constructed from metal and not plastic and of the design indicated in figure 3 For further guidance for wall fixing in timber framed buildings refer to any relevant local codes of practice Flat Wall Fixing All Models To assist with fixing the appliance a template is provided The L23 model template is shown for the purposes of example in figure 4 Mark the positions shown as Fixing points on the wall If a concealed gas connection is to be made ensure the gas supply pipe is in its final position and can enter the appliance in the correct position when the appliance is hung on the wall Drill the wall as appropriate for the type of wall as previously descri
36. y and then lift the entire casing assem Vv TS bly upwards and remove le Fab models To remove the right hand casing side SANS panel remove the two screws shown in figure 16 then pull the right hand side forward and then side ways Note to remove the burner it is only neces sary to remove the right hand side panel The same method is used should it be necessary to remove the left hand panel All models To remove the burner undo the two screws retaining the burner support bracket desig nated b in figure 14 to the base and rear of the firebox and undo the four retaining screws on the right hand side panel near the control valve as shown in figure 15 The burner may now be removed b a Figure e o View on C Remove the pilot and main burner pipes and blow through to dislodge any debris Now remove the restrictor elbow and blow through to make sure it is entirely clear Unclip the pilot lint gauze and clean with a soft brush Clean the exterior of the pilot assembly with a soft brush and blow through the flame ports on the pilot head Check the aeration holes are free from lint or dirt The pilot assembly can be removed if required by disconnecting the electrode HT lead gas pipe and unscrewing the mounting screws and lifting away The pilot assembly is a non serviceable item and should not be taken apart Aeration holes Figure 16 must be absolutely cle