Home

STEINEL HS-FE 150

image

Contents

1. 0 Espoo Tel 358 9 682881 Fax 358 9 68284278 www hedtec fi steinel info hedtec fi o D D o D D D 5 GoVilan AS Tvetenveien 30 B N 0666 Oslo Tel 47 22725000 Fax 47 22725001 post vilan no PANOS Lingonis Sons O E Aristofanous 8 Str GR 10554 Athens Tel 30 210 3212021 Fax 30 210 3218630 lygonis otenet gr EGE SENSORLU AYDINLATMA ITH IHR TIC VE PAZ LTD STI GERSAN SAN SITESI 659 SOKAK NO 510 BATIKENT ANKARA Tel 90 312 2571233 Fax 90 312 2556041 www egeaydinlatma com ege 8 egeaydinlatma com ELNAS s r o Oblekovice 394 CZ 67181 Znojmo Tel 420 515 220126 Fax 420 515 244347 infoGelnas cz www elnas cz DLANGE EUKASZUK Sp j Byk w 25a PL 55 095 Mirkow Tel 48 71 3 98 08 861 Fax 48 71 3 98 19 firma langelukaszuk pl www langelukaszuk pl DINOCOOP KFT Radvany u 24 H 1118 Budapest XI Tel 36 1 3 19 30 64 Fax 36 1 3 19 30 66 www dinocoop hu dinocoop dinocoop hu KVARCAS Neries krantine 32 LT 48463 Kaunas Tel 370 37 408030 Fax 370 37 408031 infoGkvarcas lt FORTRONIC AS Teguri 45c EST 50113 Tartu Tel 372 7 475208 Fax 372 7 367229 info fortronic ee LOG Zabnica D O O Podjetje Za Trgovino Srednje Bitnje 70 SLO 4209 Zabnica Tel 386 42 312000 Fax 386 42 312331 info log si Neco S r o Ruzova ul 111 SK 01901 Ilava Tel 421 42 4 44 14 55 Fax 421 42 4 44 14 56 steinel neco sk STEINEL Trading s r l St
2. 0 W R7s 6mm 6mm EIHs FE 500 9540000 Ef Hs FE 150 L i 10 mm E NO St go zr STEINER ENGLISH Principle The HS FE 150 and HS FE 500 halogen floodlights with wireless receiver can receive wireless signals from as many as eight Steinel transmitters with different addresses for switching the light ON The wireless receiver only responds to transmitters that have first been assigned to it For further information on setting transmitters and receivers please refer to the instructions of the IMPULSER system Safety warnings W Disconnect the power supply before attempting any work on the unit W During installation the electrical wiring you are connecting must be dead Therefore switch off the power first and use a voltage tester to make sure the wiring is off circuit W Installing these lights involves work on the mains voltage supply this work must therefore be carried out professionally in accordance with national wiring regulations and electrical operating conditions VDE 0100 6VE ONORM E 8001 1 SEV 1000
3. STEINEL pulo HS FE 150 HS FE 500 7 p HS FE 150 y WIRELESS iiz gt Receiver 180 x 158 x 166 mm 205 x 205 x 246 mm 230 240 V 868 3 MHz max 150 W R7s max 800 W L HS FE 500 max 500 W R7s HS FE 150 HS FE 500 AN IP 44 26 mm 6mm EIHs FE 500 9540000 Ef Hs FE 150 L i 10 mm E NO St go zr STEEL DEUTSCH Das Prinzip Die Halogen Strahler mit Funk Empf nger HS FE 150 und HS FE 500 empf ngt Funksignale von bis zu acht Steinel Sendern mit unterschiedlichen Adressen und schaltet das Licht an Der Funk Empf nger reagiert nur auf Sender die ihm vorher zugeordnet worden sind Weitere Informationen zur Einstellung von Sendern und Empf ngern entnehmen Sie bitte der Anleitung IMPULSER System Sicherheitshinweise W Vor allen Arbeiten am Ger t die Spannungszufuhr unterbrechen W Bei der Montage mu die anzuschlieBende elektrische Leitung spannungsfrei sein Daher als Erstes Strom abschalten und Spannungsfreiheit mit einem Spannungspr fe
4. W Do not install the unit on normally flammable surfaces W The halogen floodlight must not be directed at the wall it is mounted on W The light must be set to a horizontal position 15 W Suitable for outdoor and indoor use inndoor max 25 C as no draft air inf The floodlight must be mounted in such a way that when it is set at any possible angle a minimum distance of 1 metre is guaranteed between the light and the surface it shines on Wi Halogen floodlights are only intended for wall mounting and not for ceiling mounting They must be installed at least 1 m from the ceiling BPS If the glass cover breaks always fit a new one before continuing use Only EJH 4 replace with special tempered glass in a thickness of 5 mm HS FE 150 4 mm W To avoid inflammation of the skin and eyes do not expose yourself for any length of time to the halogen floodlight if it is being operated at a voltage of 10 above the specified voltage rating W The floodlight housing heats up to a very high temperature while it is switched ON Only adjust the angle of the floodlight once it has cooled down W Only use genuine replacement parts W Do not dismantle the light yourself It must only be repaired by a specialist workshop Installation EM ET The mains supply lead is a 3 core cable L phase conductor usually black or brown N neutral conductor usually blue PE protective earth conductor green yellow Projected floo
5. caused by material flaws or manufacturing faults The warranty will be met by repair or replacement of defective parts at our own discretion The warranty does not cover damage to wear parts or damage and defects caused by improper treatment maintenance or the use of non genuine parts Further consequential damage to other objects is excluded Claims under the warranty will only be accepted if the unit is sent fully assembled and well packed with a brief description of the fault a receipt or invoice date of purchase and dealer s stamp to the appropriate Service Centre Service Our Customer Service Department will repair faults not covered by warranty or after the warranty period Please send the product well packed to your nearest Service Centre 4 Saal Service STEINEL Schnell Service DieselstraBe 80 84 33442 Herzebrock Clarholz Tel 49 5245 448 188 Fax 49 5245 448 197 www steinel de info steinel de Gol MULLER Peter Paul Str 15 A 2201 Gerasdorf bei Wien Tel 43 2246 2146 Fax 43 2246 25466 info imueller at PUAG AG Oberebenestrasse 51 CH 5620 Bremgarten Tel 41 56 6488888 Fax 41 56 6488880 info puag ch STEINEL U K LTD 37 Manasty Road Orton Southgate GB Peterborough PE2 6UP Tel 44 1733 238 265 Fax 44 1733 238 270 steinel steineluk com SOCKET TOOL COMPANY 8 Queen Street IRL Dublin 7 Tel 353 1 8725433 Fax 353 1 8725195 sockettool eircom net CODUVAUCHEL S A ACTICENTRE CTR 2 Rue
6. des Famards Bat M Lot 3 F 59818 Lesquin Cedex T l 33 3 20 30 34 00 Fax 33 3 20 30 34 20 www duvauchel com info duvauchel com VSA HEGEMA B V Christiaan Huygensstraat 4 NL 3291 CN Strijen Tel 31 78 6744444 Fax 31 78 6743113 info vsahegema nl VAN SPIJK AGENTUREN B V Postbus 2 NL 5688 ZG Oirschot De Scheper 260 NL 5688 HP Oirschot Tel 31 499 571810 Fax 31 499 575795 info vanspijk nl www vanspijk nl VSA handel Bvba Fabriekstraat 145 B 3900 Overpelt Tel 32 11 660720 Fax 32 11 660729 info vsahandel be www vsahandel be COA R Tech 19 Rue Eugene Ruppert Cloche D Or BP 1044 L 1010 Luxembourg Tel 352 49 3333 Fax 352 40 2634 com artech lu THOELKE DISTRIBUZIONE S N C Via Adamello 2 4 1 22070 Locate Varesino Como Tel 39 331 836911 Fax 39 331 836913 thoelke distribuzione thoelke it COSAET 94 S L C Trepadella n 10 Pol Ind Castellbisbal Sud E 08755 Castellbisbal Barcelona Tel 34 93 772 28 49 Fax 34 93 772 01 80 saet94 saet94 com Pronodis Solug es Tecnol gicas Lda Rua do Caseiro no 87 A B Vilar P 3810 078 Aveiro Tel 351 234 484031 Fax 351 234 484033 pronodis pronodis pt KARL H STROM AB Verktygsvagen 4 S 55302 J nk ping Tel 46 36 31 42 40 Fax 46 36 31 42 49 www khs se kontakt khs se BROMMANN Ellegaardvej 18 DK 6400 Senderborg Tel 445 7442 8862 Fax 445 7443 43 60 brommann brommann dk Oy Hedtec AB Mankimiehentie 4 FIN 0278
7. dlight area HS FE 150 approx 240 cm HS FE 500 approx 448 cm Important Getting the cable connections crossed will produce a short circuit in the unit or in your fuse box In this case you must identify the individual cables and re connect them A mains switch for switching the light ON and OFF can of course be installed in the mains lead Concealed wiring Ell EM Surface wiring EI Underneath the mounting plate you will find two lugs for surface wiring Break off one of the two lugs Use the sealing plug to close off the cable opening in the mounting plate Pierce the sealing plug and feed the cable through Once the cable has been pushed through you can screw the mounting plate to the moun ting surface and complete the connection Troubleshooting Fault Cause gt Remedy No voltage Fuse faulty or not switched ON line broken gt New fuse or turn ON mains power switch check wiring with voltage tester Short circuit Check connections Declaration of conformity This product complies with Low Voltage Directive 06 95 EC EMC Directive 04 108 EC and RoHS Directive 02 95 EC Functional Warranty This Steinel product has been manufactured with utmost care tested for proper operation and safety and then subjected to random sample inspection STEINEL guarantees that it is in perfect condition and proper working order The warranty period is 36 months and starts on the date of sale to the consumer We will remedy defects
8. eparatur darf nur durch eine Fachwerkstatt durchgef hrt werden Installationshinweise Ell IM Die Netzzuleitung besteht aus einem 3 adrigen Kabel L Phase meistens schwarz oder braun N Neutralleiter meistens blau PE Schutzleiter gr n gelb Wichtig Ein Vertauschen der Anschl sse f hrt im Gerat oder Ihrem Sicherungskasten spater zum KurzschluB In diesem Fall m ssen die einzelnen Kabel identifiziert und neu montiert werden In die Netzzuleitung kann selbstverstandlich ein Netzschalter zum EIN und AUS Schalten montiert sein Zuleitung Unterputz Ell EA Zuleitung Aufputz EI F r eine Auf Putz Verdrahtung sind zwei Laschen unten an der Montageplatte vorgesehen Eine der beiden Laschen abknicken Die Kabel ffnung der Montageplatte mit dem Dichtstopfen verschlie en Diesen durchstoBen und das Kabel durchf hren Wenn das Kabel durchgef hrt ist kann die Montageplatte angeschraubt und der Anschlu vorgenommen werden Betriebsst rungen St rung Ursache gt Abhilfe Ohne Spannung Sicherung defekt bzw nicht eingeschaltet Leitung unterbrochen gt neue Sicherung bzw Netzschalter einschalten Leitung mit Spannungspr fer berpr fen Kurzschluss gt Anschl sse berpr fen Konformit tserkl rung Dieses Produkt erf llt die Niederspannungrichtlinie 06 95 EG die EMV Richtlinie 04 108 EG und die RoHS Richtlinie 02 95 EG Funktionsgarantie Dieses Steinel Produkt ist mit gr ter Sorgfalt hergestellt funktions
9. r berpr fen W Bei der Installation dieser Ger te handelt es sich um eine Arbeit an der Netzspannung sie mu daher fachgerecht nach den l nderspezifischen Installationsvorschriften und AnschluBbedingungen durchgef hrt werden VDE 0100 VE NORM E 8001 1 SEV 1000 W Montieren Sie das Ger t nicht auf gew hnlich leicht entflammbaren Oberfl chen Der Halogenstrahler darf nicht gegen die Montagewand gerichtet werden W Strahler mu in waagerechter Stellung 15 stehen W Geeignet f r AuBen und f r Innenr ume Innenr ume bis 25 C ohne Luftzirkulation vl Die Montage der Strahler mu so vorgenommen werden da f r alle m glichen Schwenk positionen ein Mindestabstand von 1 Meter zur angestrahlten Fl che gew hrleistet ist W Die Halogenstrahler sind nur f r die Wandmontage und nicht f r die Deckenmontage vorgesehen Der Abstand zur Decke mu mindestens 1 m betragen E EH Ar Im Fall eines Scheibenbruchs vor Wiederinbetriebnahme unbedingt eine neue Scheibe einsetzen Es ist ein 5 mm dickes getempertes Spezialglas erforderlich HS FE 150 4 mm W Wer sich dem Halogen Strahler bei Betrieb mit 10 berspannung f r l ngere Zeit aussetzt muB mit Haut und Augenentz ndungen rechnen W Das Strahlergeh use wird w hrend des Betriebes sehr hei Die Ausrichtung des Strahlers nur durch f hren wenn dieser abgek hlt ist W Nur Original Ersatzteile verwenden W Ger t nicht selbst zerlegen Die R
10. r Lunga 123 RO 507055 Cristian Brasov Tel 40 2 68 25 74 00 Fax 40 2 68 25 76 00 www steinel ro info steinel ro Daljinsko Upravljanje d o o B Smetane 10 HR 10 000 Zagreb Tel 3 85 1 3 88 02 47 Fax 3 85 1 3 88 02 47 daljinsko upravljanje zg t com hr www daljinsko upravljanje hr Go Ambergs SIA Brivibas gatve 195 16 1V 1039 Riga Tel 3 71 7 55 07 40 Fax 3 71 7 55 28 50 www ambergs lv ambergs ambergs Iv IT und R GmbH Kuibyshev Str 78 RUS 620026 Ekaterinburg Tel 7 34 32 24 23 23 Fax 7 34 32 61 61 65 itr ural ru SVETILNIKI Str Malaya Ordinka 39 RUS 113184 Moskau Tel 7 95 2 37 28 58 Fax 7 95 2 37 11 82 goncharov o svet rz STEINEL
11. und sicherheitsgepr ft nach geltenden Vorschriften und anschlie end einer Stichprobenkontrolle unterzogen Steinel bernimmt die Garantie f r einwandfreie Beschaffenheit und Funktion Die Garantiefrist betr gt 36 Monate und beginnt mit dem Tag des Verkaufs an den Verbraucher Wir beseitigen M ngel die auf Material oder Fabrikationsfehlern beruhen die Garantieleistung erfolgt durch Instandsetzung oder Austausch mangelhafter Teile nach unserer Wahl Eine Garantieleistung entf llt f r Sch den an Verschlei teilen sowie f r Sch den und M ngel die durch unsach gem e Behandlung Wartung oder durch Verwendung von Fremdteilen auftreten Weitergehende Folge sch den an fremden Gegenst nden sind ausgeschlossen Die Garantie wird nur gew hrt wenn das unzer legte Ger t mit kurzer Fehlerbeschreibung Kassenbon oder Rechnung Kaufdatum und H ndlerstempel gut verpackt an die zutreffende Servicestation eingesandt wird Service Nach Ablauf der Garantiezeit oder M ngeln ohne Garantieanspruch repariert unser Werkservice Bitte das Produkt gut verpackt an die n chste Servicestation senden Projizierte Fl che des Strahlers HS FE 150 ca 240 cm HS FE 500 ca 448 cm 3 Saal STEINEL E Ne wd HS FE 150 HS FE 500 pulo HS Fe 501180 x 158 x 166 mm A JIP 44 Hs FE 500 205 x 205 x 246 mm 4 230 240 V K 868 3 MHz IHS FE 1501 max 150 W R7s max 800 W L Y Y SER max 50