Home

Omnitron miConverter Gx

image

Contents

1. CA 92618 USA E mail support omnitron systems com URL http www omnitron systems com Form 040 12000 001D 11 07 Page 16
2. Or you may register your product on the Internet at http www omnitron systems com During the warranty period Omnitron will at its option repair or replace a product which is proven to be defective For warranty service the product must be sent to an Omnitron designated facility at Buyer s expense Omnitron will pay the shipping charge to return the product to Buyer s designated US address using Omnitron s standard shipping method Page 13 SPECIFICATIONS CONT W 1 71 x L 4 10 x H 0 84 Dimension WxDxH Weight with USB power adapter cable with AC power adapter Universal Compliance UL CE FCC Class A Temperature Operational 0 to 50 C Storage 50 to 80 C Humidi 5 to 95 non condensing Altitude ft 100m to 4000m MTBF hrs without power adapter 810 000 with US and Country Region Specific 250 000 power adapter with Universal power adapter 100 000 Page 10 Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate use and or maintenance of the equipment by Buyer Buyer supplied equipment Buyer supplied interfacing unauthorized modifications or tampering with equipment including removal of equipment cover by personnel not specifically authorized and certified by Omnitron or misuse or operating outside the environmental specification of the product including but not limited to voltage ambient temperature radiati
3. is a loss of a receive link on the fiber optic port the UTP port continues to maintain its link Fig 2 A amp B Setting this DIP switch to LP allows the link state to propagate from one port to the other port In this configuration the loss of a receive link on either port causes the transmit link of the opposite port to be turned off For example a loss of a receive link on the fiber optic port causes the UTP port to drop its link due to the propagated fiber optic link state Fig 2 C This setting allows the loss of a link to be detected by SNMP or other managed network devices to which the miConverter Gx is connected Note Only the first loss of a receive link detected by the miConverter Gx turns off the other port s transmit link An additional loss of a receive link on the other port has no affect on the miConverter Gx The miConverter Gx returns to normal operation when the first loss of a receive link is restored Page 6 WARNING Before inserting the Power Adapter verify that the power on the unit is appropriate for your AC line voltage source POWER ADAPTER NOTICE This product should only be used with Omnitron supplied Power Supply model numbers 9113 PS 9115 PS 9116 PS 3 9116 PS 4 9116 PS 5 or 9116 PS 8 When powering the miConverter Gx using the USB Power Adapter cable P N 9130 2 the cable must be connected to a Full Powered USB Type A port 5V 500mA Note Not all USB Type A ports are
4. 16 PS 5 Penerse nes o 9115 PS Japanese AC Power Supply Europe Connector Clip UK Connector Clip Australia Connector Clip Japanese Connector Clip All spare Connector Clips are interchangeable with AC Power Adapters 9116 PS 3 9116 PS 4 9116 PS 5 and 9116 PS 8 DESCRIPTION The miConverter Gx converts between 1000BASE T copper and 1000BASE X Gigabit Ethernet fiber The fiber optic port supports Auto negotiation and Manual configuration via DIP switches The UTP port automatically detects and advertises the Duplex and Pause abilities of connected Gigabit fiber optic and UTP devices The 1000BASE X fiber port supports ST and SC fiber connectors Single fiber and dual fiber models are listed in the table on the first page of this manual Page 2 UTP Pause Enable Disable Pause No DIP switch Setting this DIP switch to Pause factory default allows the UTP port to negotiate to Symmetrical Pause Setting this DIP switch to No disables Pause These settings must be configured to match the settings of the connected fiber optic and UTP devices Link Segment Link Propagate LS LP DIP switch Setting this DIP switch to LS factory default allows the generation and detection of link presence to occur at each point to point segment In this configuration the loss of a receive link on either port has no affect on the other port s ability to transmit a link For example if there
5. Full Powered USB ports The Full Powered USB Type A ports are usually the USB ports found on computer cases or on self powered powered by an AC adapter USB hubs INSTALLATION PROCEDURE 1 Configure the appropriate miConverter Gx DIP switch settings If connecting to a fiber optic device that is set to auto negotiation mode set the fiber optic Auto negotiation Manual AN Man DIP switch to AN If connecting to a fiber optic device that is set to manual mode set the fiber optic AN Man switch to Man and the UTP DIP switches to the settings of the connected devices 2 Connect the UTP port to a 1000BASE T Ethernet device using a Category 5 cable or better 3 Connect the fiber optic port to a 1000BASE X Gigabit Ethernet device using a single mode or multimode fiber cable as appropriate When connecting dual fiber models Page 3 LS LS gt gt gt UTP Fiber UTP A i ya l4 Fiber O a Switch 1 Converter A Converter B Switch 2 LS LS gt PRL gt B O j4 4 Switch 1 Converter A Converter B Switch 2 LP LP gt lt gt gt N C lt 4 oO Khe Switch 1 Converter A ConverterB Switch 2 LEDLit YX LED Off Fig 2 Manual Link Modes Page 7 the miConverter Gx transmitter Tx must attach to the receiver side of its link partner the receiver Rx must attach to the trans
6. Setting this DIP switch to the Manual Man setting disables the fiber optic port s ability to detect the Duplex and Pause modes of the connected fiber optic device In this setting the UTP port of the miConverter Gx negotiates with the connected UTP device based on the modes configured by the UTP DIP switches This setting allows the miConverter Gx to connect to Gigabit fiber devices that are not capable of auto negotiation Note In auto negotiation mode connecting the fiber optic cables before connecting the UTP cables causes the fiber optic LED to blink steadily 0 5Hz The blinking LED turns solid when the UTP link is on and blinks quickly 10Hz when activity is detected Note The UTP FDX HDX Pause No and LS LP DIP switches have no affect when the fiber optic port is set to auto negotiation UTP Full Half Duplex FDX HDX DIP switch Setting this DIP switch to FDX factory default allows the UTP port to negotiate to Full Duplex Setting this DIP Switch to HDX forces the UTP port to negotiate only to Half Duplex These settings must be configured to match the settings of the connected fiber optic and UTP devices Page 5 Optional Accessories Wall Mounting Hardware Kit USB Power Adapter Cable 9130 2 US Domestic AC Power Supply 9113 PS Universal AC Power Supply requires AC power cord Europe AC Power Supply 9116 PS 3 UK AC Power Supply 9116 PS 4 Australia AC Power Supply 91
7. UTP isat UTP is at Full Duplex Duplex Half Duplex Note For additional assistance with LED indicators please refer to the miConverter Gx TROUBLESHOOTING GUIDE pp 11 12 Page 8 SPECIFICATIONS 1000BASE T UTP to 1000BASE X Description Copper to Fiber Media Converter with Auto negotiation al EIA TIA 568A B UTP Cable Type Category 5 and higher Multimode 50 125 Fiber Cable Type 62 5 125 100 140um Single mode 9 125um Fiber Connector Types poole fiber SC Power Requirements Minimum DC Power 0 5A 5VDC DC Power Connector 2 5mm DC Jack Center Positive AC Power Adapter 100 120VAC 60Hz US 0 03A 120VAC AC Power Adapter F f Universal and 1 a to Gore Country Region Specific Page 9 Warning The operating description in this Instruction Manual is for use by qualified personnel only To avoid electrical shock do not perform any servicing of this unit other than that contained in the operating instructions unless you are qualified and certified to do so by Omnitron Systems Technology Inc Warranty This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment TO REGISTER COMPLETE AND MAIL OR FAX THE ENCLOSED REGISTRATION FORM TO THE INDICATED ADDRESS
8. complete indicating connected devices are not able to complete auto negotiation Possible Causes A Confirm that the miConverter Gx and the connected fiber optic and UTP devices are set to auto negotiation Page 11 Page 15 mode If the connected fiber device does not support auto negotiation configure the miConverter to MAN mode B Confirm that the UTP cables of the miConverter Gx and the connected fiber optic and UTP devices are properly connected C If two miConverter Gx converters are connected via fiber confirm that both converters have their fiber optic ports set to auto negotiate AN and their UTP ports connected to remote devices D Confirm that the connected UTP and fiber optic devices have the same Duplex Pause capabilities Problem The UTP link LED does not illuminate after installation is complete Possible Causes A Confirm that the UTP cable is connected properly to the miConverter Gx and the attached UTP device B Confirm that the UTP cable pin out is correct EIA TIA 568 A C Confirm that the attached UTP device is working properly and is capable of Gigabit Ethernet speed Note If corrective actions do not resolve your situation please contact Omnitron Systems Technical Support Page 12 TECHNICAL SUPPORT For help with this product contact Omnitron s Tech Support Phone 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 140 Technology 500 Irvine
9. mitter When connecting single fiber SF models the Tx wavelength on one end has to match the Rx wavelength on the other Based on this guideline the SF media converter models must be used in pairs such as the 1210 2 x matched with the 1211 2 x 4 Mount the miConverter Gx using the included Velcro strips or optional wall mounting bracket kit P N 1091 0 5 Connect the appropriate power supply DIP SWITCH SETTINGS Link Propagate LP UTP No Pause No UTP Half Duplex HDX UP r F O Manual Negotiate Man as y DOWN L F o Auto negotiate AN UTP Full Duplex FDX UTP Pause Enabled Pause Link Segment LS Fig 1 DIP switches Fiber Optic Auto Manual AN Man DIP switch Setting this DIP switch to the Auto negotiation AN factory default setting enables the fiber optic port of the miConverter Gx to negotiate the Duplex and Pause modes with the connected fiber optic and UTP devices The Page 4 LED INDICATORS Function Color Legend Off State On Blinking State Power Amber PWR No power Amber power F O link Act Green No fiber Green link optic link Green rapid blink 10Hz data Green slow blink 0 5Hz fiber cable is connected but unable to complete auto negotiation F O Auto Neg Green Manual Auto negotiation mode mode UTP link Act Green No UTP Green link link Green rapid blink 10Hz data Full Half Green
10. on unusual dust etc or improper site preparation or maintenance No other warranty is expressed or implied Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose Exclusive Remedies The remedies provided herein are the Buyer s sole and exclusive remedies Omnitron shall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any legal theory Page 14 TROUBLESHOOTING GUIDE Problem The Power LED does not illuminate after installation is complete Possible Causes A Confirm that the power supply is connected B Confirm that the correct power supply is being used Problem The Fiber Optic link LED does not illuminate after installation is complete Possible Causes A Confirm that the fiber optic cable is properly connected to the miConverter Gx and the remote fiber optic device B Confirm that the fiber cable type matches the fiber transceiver type multimode single mode on the miConverter Gx C If using a dual fiber model confirm that the transmitter Tx is attached to the receiver side of its link partner and that the receiver Rx is attached to the transmitter D If using a single fiber model confirm that the Tx wavelength on the miConverter Gx matches the Rx of the connected fiber optic device Problem The Fiber Optic link LED blinks slowly after installation is
11. osr Omnitron Systems Technology Inc miConverter Gx Media Converter User Manual a Unit shown with optional wall mounting bracket kit miConverter GX Models Fiber Type Dual Fiber DF or Distance Single Fiber SF MM DF SM DF SM DF ST sc Connector Connector Wavelength Wavelength 1200 0 x 1202 0 x 1203 1 x 1310 1310 34km 1203 2 x 1310 1310 80km 1203 3 x 20km 1211 1 x 1550 1310 40km 1210 2 x 1550 1310 When ordering power options replace x in the model number with the suffix number that corresponds to the selected power supply Example 1203 2 6 SM DF 34km with a USB Power Adapter Cable SM SF SM SF US Power Supply 120Volt 60Hz Universal Power Supply requires AC power cord 100 240Volt 50 60Hz Europe Power Supply 100 240Volt 50 60Hz UK Power Supply 100 240Volt 50 60Hz Australia Power Supply 100 240Volt 50 60Hz USB Power Adapter Cable US JPN Power Supply 100 240Volt 50 60Hz ooakon For power supplies 3 4 5 and 8 country region specific clips are used to provide the necessary power connection miConverter Gx UTP port negotiates with the connected UTP device based on the modes detected by the fiber optic port Both the miConverter Gx and the connected fiber optic device must have their fiber optic auto negotiation enabled for this process to work