USER MANUAL - Instrumart

image

Contents

1. L Brown or Blue White M12 Micro Connector 5 pin male receptacle J j E ij LULL W 1 BROWN VCC 2 WHITE N O J 3 BLUE VCC Sak 4 BLACK COM _ 5 GREY N C RED V 12 32 VDC BLACK V GREEN COM WHITE NC BROWN or BLUE NO NOTE 12 32 VDC power is standard For other power supply voltages a power converter must be used APPLYING POWER OTHER THAN THAT MEANT FOR THE UNIT MAY CAUSE DAMAGE AND OR INJURY 4 0 Startup and Calibration 4 1 Calibration The LLS100 is factory per set and requires no further calibration 4 2 Power up After the switch has been installed as per the installation procedure in section 3 power up the unit 4 3 Single point level switch calibration The LLS100 test calibration procedures require that the liquid level in the vessel may be varied NOTE FOR HORIZONTAL PROBES CALIBRATION SHOULD BE DONE REQUIRING THE PROBE TO BE COMPLETELY IMMERSED IN THE MATERIAL AT THE DESIRED ALARM POINT Follow the steps below Bring the level in the vessel below the probe Raise the level in the vessel to completely cover the probe POS This completes the calibration procedure 4 5 The RELAY should change state indicating that the switch is working properly LLS100 Level Switch User manual No LSM112010 Rev 1 0 NOTE FOR VERTICAL PROBES CALIBRATION TEST SHOULD BE DONE WITH THE LEVEL JUST IN CONTACT WITH THE
2. INTEMPCO Controls Ltd intem OC A 880 Selkirk Avenue Y v Pointe Claire Quebec Canada H9R 3S3 Tel 514 426 0488 Fax 514 426 0522 Email info intempco com www intempco com USER MANUAL LLS100 LEVEL SWITCH 3 mH Wut m No LSM112010 Rev 1 Safety Information The described product must be installed by qualified personnel to applicable codes and operated as described in this operating manual Read it and understand it before installing and connecting the unit for operation LLS100 Level Switch User manual No LSM112010 Rev 1 0 1 Product Description 1 1 Features e Miniature design conductivity level switch e No moving parts All wetted parts stainless steel 316 and Teflon e Alternating potential electronics e Single Pole Double Throw SPDT relay contacts e Hermetically sealed vibration resistant construction e 1 3 second time delay For high or low relay action For conductive liquids in metallic or non metallic tanks 1 2 Function and Configuration The LLS100 level sensors use conductive measuring principle for level detection of electrically conductive liquids Function When the probe is covered by electrically conductive medium it detects the product resistance The circuit is closed and a low alternating current flows from the probe which is measured by the integral electronics and converted into a switching command The switching signal is dete
3. The LLS100 level switch should be located if possible for easy access for service Sensor enclosure should not be exposed to ambient temperatures below 40 C 40 F or above 85 C 185 F It is preferable the switch is not installed in proximity to high voltage wires or other sources of high electrical noise 2 1 Conductive Probes For conductive liquids LLS100 uses bare stainless steel probe Standard length of the probe is 1 2 5cm The probe length can be customer specified for the level of liquid desired to be measured 2 2 LLS100 Installation General Standard probe entry into a tank is via 1 4 NPT opening but other fitting sizes are available When mounting the level switch it should be noted that the rod does not touch the vessel wall TO SCREW IN SWITCH THREADED ENTRY USE WRENCH ON HEX ONLY Do not use a pipe wrench on the body of the level switch Mounting in Metallic Vessel The reference ground for this installation is typically the metal wall of the vessel especially for top mounted probes Use conductive sealant such as copper on NPT threads if possible When using Teflon sealant make sure there is a GOOD ELECTRICAL CONNECTION BETWEEN THE VESSEL AND THE FITTING of the switch Use ground or conductivity tester ohm meter For horizontally or bottom mounted probes the reference ground is not as important since the change in switch output can be achieved by liquid being in contact with the probe and the switch fitt
4. PROBE Follow the steps below Bring the level in the vessel below the probe Raise the level in the vessel to be just in contact with the probe The RELAY should change state indicating that the switch is working properly This completes the calibration procedure PED Nes It is the policy of INTEMPCO to comply with all worldwide safety and EMC EMI regulations that apply INTEMPCO is constantly pursuing certification of its products to the European New Approach Directives INTEMPCO will add the CE mark to every appropriate device upon certification The information contained in this document is believed to be correct but INTEMPCO Controls Ltd accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are not designed for use in and should not be used for patient connected applications WARRANTY DISCLAIMER INTEMPCO Controls Ltd warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase INTEMPCO warranty adds an additional one 1 month grace period to the normal one 1 year product warranty to cover handling and shipping time This ensures that INTEMPCO s customers receive maximum coverage on each product If the unit malfunctions it must be returned to the factory for evaluation INTEMPCO s Customer Service Department will issue an Return Merchandise Authorized RMA number immediately upon phone
5. haser set forth herein are exclusive and the total liability of INTEMPCO with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall INTEMPCO be liable for consequential incidental or special damages CONDITIONS Equipment sold by INTEMPCO is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application used on humans or misused in any way INTEMPCO assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify INTEMPCO and hold INTEMPCO harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the INTEMPCO Customer Service Department BEFORE RETURNING ANY PRODUCT S TO INTEMPCO PURCHASER MUST OBTAIN AN AUTHORIZED RETURN RMA NUMBER FROM INTEMPCO CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PROCESSING DELAYS The assigned RMA number should then be marked on the outside of the return package and on any correspondence The purchaser is responsible for sh
6. ing However the sensitivity is higher if the grounding is good between the vessel and the fitting and therefore the operation of the switch is more dependable see Figure 1 Mounting in Non Metallic Vessel The reference ground for this installation is the fitting of the switch The circuit is closed when the conductive liquid is in contact with both the probe and the fitting A horizontally mounted rod type probe should be mounted so that the lower face of the probe is parallel to and at the level of the desired alarm point see Figure 2 Location Avoid installing rod type probes in nozzles or recesses where material can accumulate and cause false readings Also avoid installing the LSS100 close to agitators or moving objects in the vessel Alloy Tanks Conductive Plastic Tanks Non Conductive Bottom Mounted Top Mounted Bottom Mounted Top Mounted M tov te ri v4 v4 x Side Mounted Side Mounted Switching s HIIR Figure 1 Figure 2 Switching Switching 3 5 LLS100 Level Switch User manual 3 Electrical Installation No LSM112010 Rev 1 0 Normally Open NO Green Red Input Supply Black Le Brown or Blue Green Red Input Supply Eent White SPDT Normally Open or Normally Close NO or NC Green Red Input Supply Black
7. ipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have the following information FOR NON WARRANTY REPAIRS consult INTEMPCO for current repair available BEFORE contacting INTEMPCO charges Have the following information available BEFORE contacting INTEMPCO 1 Purchase Order number under which the product was PURCHASED 1 Purchase Order number to cover the COST of the repair 2 Model and serial number of the product under warranty and 2 Model and serial number of product and 3 Repair instructions and or specific problems relative to the product 3 Repair instructions and or specific problems relative to the product INTEMPCO s policy is to make running changes not model changes whenever an improvement is possible This affords our customers the latest in technology and engineering INTEMPCO stands for INTEMPCO Controls Ltd 5 5
8. or written request Upon examination by INTEMPCO if the unit is found to be defective it will be repaired or replaced at no charge INTEMPCO s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion or current heat moisture or vibration improper specification misapplication misuse or other operating conditions outside of INTEMPCO s control Components which wear are not warranted including but not limited to contact points fuses and triacs INTEMPCO is pleased to offer suggestions on the use of its various products However INTEMPCO neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by INTEMPCO either verbal or written INTEMPCO warrants only that the parts manufactured by it will be as specified and free of defects INTEMPCO MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESS OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIABILITY The remedies of purc
9. rmined by the length or mounting of the probe Configuration The LLS100 is a miniature integrated design complete with switching electronics enclosure fitting and a probe The electronics are fully potted in the housing The output is dry contacts SPDT relay The LLS100 is available with lead wires or or M12 connector 1 3 Technical Data 1 4 Dimensions 2 51 Electrical BEY Y Supply Voltage 12 32 VDC Output SPDT relay NO or NC gt Maximum Load Charge 1A 30 VDC pan 0 3A 125 VAC Dampening 1 3 seconds standard ese Sensitivity 10 K ohms resistive fluids Sane Circuit Protection Reverse Voltage f Probe Output 1 mA max 1 VAC max 5 kHz Operating temperature amp Storage temperature 40 C to 85 C 40 F to 185 F 3 58 0 625 16 Mechanical Wetted Material 316 SS and Teflon Mounting fitting 1 4 NPT std others available 25 Process Temperature 100 C max 212 F T Process Pressure 100 psi max 6 9 bar j T Electrical Termination Lead wire or M12 male receptacle C Moisture Protection IP67 NEMA 6 equivalent J E 0 187 5 2 5 LLS100 Level Switch User manual No LSM112010 Rev 1 0 2 Mounting Instructions Note Unpack the instrument carefully Inspect all components for damage If any damage is found please notify Intempco Controls Ltd or its representative as soon as possible prior to installation

Download Pdf Manuals

image

Related Search

Related Contents

User's Guide C5000 Series  2- airpass manu - A CMS - U  Sensibilité in vitro à la chloroquine de plasmodium falciparum à  User manual - Electrocomponents  1098- ART CONTEMPORANI \(12 crèdits, 8 teòrics i 4 pràctics\)  Workshop manual Park 2/4WD 2000-2008  Rapport d`activité - Ministère de la Ville    FINAL USER 1 LPF  USER`S MANUAL - Pdfstream.manualsonline.com  