1. Hysteresis Line Current Low Total Current lt Set Point Current gt Set Hysteresis Outlet Current Low Outlet X Current lt Set Point Current gt Set Hysteresis Threshold Alarm Clear Actions Outlet On Outlet Off Outlet Reboot None 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 18 SURGEX AXESS ELITE User Manual energy intelligence Firmware Version v2 04 281 5 5 7 Sequences Setup The Sequences Setup page allows for the creation and modification of sequences A sequence is a list of outlets including Auxiliary Relays that will be turned On Off or Rebooted in a predetermined way with a specified delay time between each step Using sequences avoids manually turning each outlet on or off individually for the modet purely LLL Sasan r for this product is purely a one way sequence That is you do not use the acai wat same sequence to turn Baad L outlets on as you use to turn the same outlets off in reverse order One sequence must be created for the turn on function and then a second sequence must be created for the turn off function To create a new sequence press the New Sequence button The new sequence must be given a unique name This name should clearly indicate what the sequence will do such as All On All Off or Stage Equipment On There may be up to 16 steps in a single sequence Select the time delay
2. Enable Telnet Specifies whether or not to enable the internal telnet server Telnet Port Specifies the port the internal telnet server will communicate on Enable Emai Login Name Login Password Auto Retry Test Email Set Time SNTP Server Time Zone Offset Use DST DST Start Date DST Stop Date Specifies the Month Week Day and Time that DST ends Return Address Specifies the return address of the internal email client Manual Time Set Specifies the starting date and time when using Manual mode Email Server Specifies the IP Address of the SMTP or ESMTP server to be used 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 14 SURGEX AXESS User Manual energy intelligence Firmware Version v2 04 281 5 5 3 Network Reporting Setup The Network Reporting Setup page allows for the configuration of SNMP SDxP and Syslog reporting Saving any change which requires a reboot to take effect will result in the addition of a Reboot Required button at the bottom of the page Network Reporting Setup Enable SNMP Read Communi Wie Community SNMP Managers Traps Sen SDxP Port Specifies the port to be used with the SDxP exchange protocol The SDxP protocol is the means of communication between master and expansion units all of which must use the same SDxP port and is also the API to be used with the Axess Elite SDxP Manager Specifies the IP address o
3. The Device View page provides information and status for the whole unit and individual outlets as well as basic control of outlets The top left section of the page provides system status To refresh the status information click the Refresh button 00727 KW Since 03 17 2015 Power Draw For each outlet the Outlet Name Present State Current Draw Power Draw and Energy Usage are displayed Mobile Page links are at the bottom left below the Links section Contact Closure input status is displayed Device View Description Item Overall System Indicates that the surge protection rack temperature line voltage and current draw are at acceptable levels Surge Protection Indicates that the surge protection is fully functional Rack Temperature Displays the temperature of the sensor that is connected to the rear terminal block Ifthe temperature sensor is not connected the display will read NC Line Voltage Displays the true RMS AC voltage Displays the total current draw of all 8 receptacles in true RMS Amps Displays the total power draw of all 8 receptacles in Watts Energy Used Displays the total energy consumption of the equipment plugged into the unit in KW Hours since the last counter reset Pressing Reset Energy Usage will reset the KW Hours count Turns the selected outlets on
4. The Login page is the first page displayed when a web browser makes a connection to the Axess Elite Enter a valid user name and password in the User Name and Password fields and press Login to log in to the Axess Elite A mobile login page is available at IPAddress mobile_login html 5 2 Administration 5 2 1 Reset Factory Defaults Allows resetting of factory defaults from the web interface Options to keep or reset network IP settings e Options to keep or reset calibration data 5 2 2 Backup Restore Provides Configuration Management via conf files Backup current configuration to file Restore configuration from previously saved file Option to keep current network IP settings or use those in configuration file Option to keep current calibration data or use calibration values in configuration file If restoring the calibration values Stored in a configuration file there is an option to only restore the values if the MAC address of the unit and the MAC address in the configuration file match 5 23 System Info Displays number of logged in web users time each user has been logged in and System uptime Also provides a Reboot button 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 9 SURGEX AXESS ELITE User Manual energy intelligence Firmware Version v2 04 281 5 3 Device View
5. SURGEX energy intelligence Axess Elite SX AX15E SX AX20E SURGEX Web Enabled Power Conditioning and Energy Management System User Manual Firmware Version v2 04 281 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com UM Axess Elite Rev B RNelson surgex com SCHOOL SURGE AXESS FLITE User Manual anergy intelligence Firmware Version v2 04 281 CSPG SURGEX energy intelligence energy intelligence ADVANCED SERIES MODE ECOMMANDCENTER FLATPAK MULTI STAGE SURGE DIAGNOSTIC AXESS ELIMINATOR SERIES ICE NEXT GEN SURGE PDU CERVELLA EMPOWER IMPEDANCE TOLERANT POS SURGE ELIMINATION COUVS ENERGY INTELLIGENCE INRUSH CURRENT POWERFRAME SURGEX DEFENDER SERIES ENVISION ELIMINATION REMOTE PORTAL DIGITAL QC ESP MULTIPAK SERIES MODE This product may be covered by one or more claims of the following patents or published patent application U S Patent Nos RE39 466 4 870 528 4 870 534 5 136 455 6 040 969 6 728 089 6 744 613 6 947 266 7 068 487 7 184 252 7 511 934 7 541 696 and 7 551 412 8 482 885 8 520 349 8 547 672 and 8 614 866 U S Patent Application Publication Nos 2012 0221161 2013 0073232 2012 0265361 2013 0073060 2013 0258538 and 2014 0005963 Canadian Patent No 1 332 439 1 333 191 2 461 332 and 2 511 695 2015 SurgeX Electronic Systems Protection Inc Techn
6. 002 00 00 Marin veer Dav 4H Min Sec DST Sho Date 39 t Gr 00 00 Monim Week Daw24H Min Sec Uarual Tene Set Mon Yea 22H Mim 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 13 SURGE lt AXESS User Manual energy intelligence Firmware Version v2 04 281 Network Setup Item Description IP Setup Specifies whether to use Static or DHCP mode Specifies the address to be used when in Static mode and displays the assigned address when in DHCP IP Address ode Subnet Mask al the subnet mask to be used when in Static mode and displays the assigned mask when in DHCP yl the Sate address to be used when in Static mode and displays the assigned gateway address Gateway when in DHCP mode ooo the first DNS server address to be used when in Static mode and displays the acquired address DNS1 when in DHCP mode DNS ee the second DNS server address to be used when in Static mode and displays the acquired address when in DHCP mode Specifies the port that the web server will communicate on If the port number is changed from the default value of 80 the Axess Elite s web paur may be accessed by navigating to http IPADDRESS PORTNUMBER for Web HTTP Port example http 192 168 1 1 Web HTTPS Port Specifies the port that the web server will communicate on when using secure SSL encryption SSL Required Specifies whether or not the internal web server is to use secure SSL encryption
7. 2012 09 46 00 0500 From _ lt AxessElite surgqex com gt To lt networkadmin yourco com gt Axess ELITE Cabinet_3 at 192 168 1 199 schedule1 processed at 09 46 on 07 07 2012 SNMP Axess Elite Setup and Control functions can be linked to any SNMP v2c manager Up to four SNMP managers may be set Each manager can perform all Setup and Control functions and may receive Trap notifications for System Triggers User Triggers and Manual outlet control The Axess Elite MIB is available at surgex com 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 24 4 AXESS User Manual Firmware Version v2 04 281 9 SDxP Protocol 9 1 9 2 Overview The SDxP Protocol is a packet based protocol designed to be extensible This protocol is transmitted over TCP on a user defined port The factory default SDxP port is 9100 The protocol uses a Hello handshake to establish unique sequence numbers to allow for advanced security when AES encryption is used With AES enabled all messages must be encrypted with the AES Passphrase set in the device After the Hello a Command and Response sequence follows Any number of Command Response sequences are permitted after Hello Hello Handshake The client sends a Hello message in the form of a text string hello 000 The SDxP enabled Axess Elite will respond with a packet containing the unsigned 16 bit sequence number This sequence number is inc
8. N O1 Q W oO AW L N O1 Q UJ oO L N O1 Q W Qo o N Common Mode 50Q load Under Voltage Auto Shutdown Adjustable from 80V to 110V or disabled Adjustable from 130V to 160V Over Current Auto Shutdown Adjustable from 1A to 20A or disabled Over Temperature Auto Shutdown Adjustable from 70 to 100 F or disabled oltage 1 from 90 160 VRMS 1 from 0 1 20 ARMS Resistive 5 from 0 1 2400 WRMS Resistive 5 kWh ver Voltage Auto Shutdown Oo WO GO D Oo A L N C Oo UJ L N On Oo gJ Ol L N on Oo Q JJ MNO L N Measurement Accuracy m Sd oo oo nergy mi OIS 5 ODI OD gt 25 105C 10 100 Ethernet connection on Female RJ 45 Auto Negotiating with 10 100 1000 network connections with Link and Activity LEDs S 232 on Female 9 pin D subminiature DCE x screw terminal 3 x screw terminal emperature erial Port emperature Sensor Input uxiliary Relay Outputs ontact Closure Input NO AJ I n wo O 3 ND on X screw terminal 9 W x 12 25 D x 1 75 H Single Rack Space 3 Ib C to 35C to 95 R H Non condensing ETL Certified to UL 1449 3 Edition imensions Weight emperature Range x umidity Range ETL Certified to UL 1283 5 Edition ETL Certified to CSA 22 2 No 8 M1986 R2008 1 2 x 50 microsecond industry standard
9. Support 800 645 9721 surgex com 27 Descriptors elnform_outletStatus elnform_auxRelayStatus elnform_lineVoltage elnform_lineCurrent elnform_linePower elnform_outletCurrent elnform_outletPower elnform_sysStatus elnform_poll elnform_overVoltage elnform_underVoltage elnform_overCurrent elnform_overT emperature elnform_selfTestFail elnform_userTriggerClear elnform_userTriggerFail elnform_manualControl elnform_systemTriggerClear AXESS Description This inform is used to tell the manager the status of all 8 outlets It is also the response to the getOutletStatus and setOutletStatus commands This inform is used to tell the manager the status of the 2 auxiliary relays It is also the response to the getAuxRelayStatus and setAuxRelayStatus commands This inform is used to tell the manager the line voltage It is also the response to the getLineVoltage command This inform is used to tell the manager the total line current It is also the response to the getLineCurrent command This inform is used to tell the manager the total line power It is also the response to the getLinePower command This inform is used to tell the manager the current draw of each of the individual outlets It is also the response to the getOutletCurrent command This inform is used to tell the manager the power draw of each of the individual outlets It is also the response to the getOutletPower command This inform is used to tell
10. combination wave surge as per IEEE C62 41 CAUTION Do not install this device if there is not at least 10 meters 30 feet or more between the electrical outlet and the electrical service panel 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 34
11. from the Pause column Select the outlet from the Outlet column x EdtSequeneei Select whether the outlet is to tum eee pn off turn on or reboot from the Action column Press the Save Step Pause Outlet Action Step button to save the sequence BO Me None z ue To run a sequence to test it press ml aoa Dd eae one zl Run To edit an existing sequence en ee press Edit To delete a sequence F ma mas F F em mm After a sequence has been saved it Aa will be available at the bottom of the Device View page and when See close creating or editing a User Trigger when a sequence is selected as an action Time delay is specified from the previous sequence item not from the initial starting point For example creating a sequence with Step 1 1 second Outlet 1 On and Step 2 1 second Outlet 2 On will turn on Outlet 1 after 1 second and Outlet 2 on 1 second after Outlet 1 has turned on This sequence will not turn on both Outlets 1 and 2 at the same time 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 19 SURGE Y AXESS ELITE User Manual energy intelligence Firmware Version v2 04 281 5 5 8 Links Setup The Links Setup page allows for the setup of Axess Elite Expansion units and Favorites Expansion units are other Axess Elite units
12. the manager the entire system status all above metrics It is sent every X minutes bY the managed device to keep the manager in sync It is als o the response to the getSysStatus command This inform is used as the response to the Poll command The Poll commana is used by the Axess Elite to poll Expansion units This inform is sent whenever a Sata Trigger Over Voltage occurs This inform is sent whenever a System Trigger Under Voltage occurs This inform is sent whenever a ll Trigger Over Current occurs This inform is sent whenever a on Trigger Over Temperature occurs This inform is sent whenever a System Trigger Self Test Failure occurs This inform is sent whenever any User Trigger clears This inform is sent whenever any User Trigger fails This inform is sent whenever a manual outlet state change is made Ni inform is sent whenever any System Trigger clears 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com User Manual Firmware Version v2 04 281 Payload tOutletStatus tAuxStatus tLineVoltage tLineCurrent tLinePower tOutletCurrent tOutletPower tSysStatus tPoll tInformOverVoltage tInformUnderVoltage tInformOverCurrent tInformOverTemperature None tInformUserTriggerClear tInformUserTriggerFail tInformManualControl tInformSystemTriggerClear 28 SURGE AXESS User Manual energy intelligence Firmware Version v2 04 281 eType_
13. v2 04 281 Exit Exits the DMU program Help Online Help Opens a web browser to online help resources About Displays DMU version information Syslog The Axess Elite contains a built in Syslog client When enabled it will send Syslog formatted UDP messages on port 514 Messages will be sent for the following System Triggers Over Voltage Auto Shutdown Trigger Over Voltage Auto Shutdown Clear Under Voltage Auto Shutdown Trigger Under Voltage Auto Shutdown Clear Over Current Auto Shutdown Trigger Over Current Auto Shutdown Clear Over Temperature Auto Shutdown Trigger Over Temperature Auto Shutdown Clear Self Test Failure Auto Shutdown Trigger Self Test Failure Auto Shutdown Clear Example 02 24 2012 13 55 14 System4 Alert 10 1 2 69 02 24 2012 13 55 15 Cabinet_1 System Trigger Over Temperature Alarm Rear Panel Reset Button The recessed reset pushbutton located on the rear panel to the right of the Network connection performs three functions Reboot Password Reset and Factory Default Reset Pressing the reset button once quickly will reboot the Axess Elite The outlets will be set to the states specified by their Initial State parameters This operation will also clear a Persistent Shutdown State Holding the reset button for 5 seconds or longer will initiate a recovery mode Once the reset button is released the user has 30 seconds to log in to the CLI using the username admin and password admin After logging in during recovery mode
14. 45 connector for Ethernet is situated on the rear panel beside the Serial connector The default IP Address is 192 168 1 199 RS232 Serial Port Connection The Axess Elite has a 9 pin D subminiature connector for RS 232 serial control The connector is configured as DCE for direct connection to a laptop or other terminal device Default serial parameters are 115 200 bps 8 data no parity 1 stop bit 9600 8 n 1 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 7 SURGE AXESS User Manual energy intellige Firmware Version v2 04 281 3 4 Temperature Sensor In order to obtain a temperature reading the external temperature sensor must be connected to the first far left terminal block The sensor has two wires red and black Connect the red wire to pin 1 and the black wire to pin 2 The sensor can be positioned to read air temperature at any location in the rack although the top of the rack would be optimal since heat rises it can also be placed in contact with the chassis of a particular piece of equipment that you want to monitor Contact Closure Auxiliary Relay A Auxiliary Relay B Red Black 3 5 Contact Closure Input Connect a contact closure control input if any to the 2 pins of the second terminal block Relays switches and push buttons are all suitable input types The actions to be executed upon closing or opening of the contact closure input may be defined as various Us
15. Commands Commands are used to control and query the managed device typedef enum eCommands_null eCommands_setOutletStatus eCommands_getOutletStatus eCommands_getOutletCurrent eCommands_getOutletPower eCommands_setAuxRelayStatus eCommands_getAuxRelayStatus eCommands_getLineVoltage eCommands_getLineCurrent eCommands_getLinePower eCommands_getSysStatus eCommands_poll eCommands Payload eCommands_null This is a null command and should None None not be used eCommands_setOutletStatus This command is used to control an tOutletCommand elnforms_OutletStatus individual outlet Note The inform returned as a result of the command will reflect the current outlet state and will not reflect the requested change eCommands_getOutletStatus This command is used to get the elnforms_OutletStatus Status of all outlets eCommands_getOutletCurrent This command is used to get the None elnforms_OutletCurrent eCommands_getOutletPower This command is used to get the None elnforms_OutletPower eee peqana o I O eCommands_setAuxRelayStatus This command is used to set the tOutletCommand elnforms_AuxRelayStatus eee saci a o eCommands_getAuxRelayStatus This command is used to get the None elnforms_AuxRelayStatus ipana ff eCommands_getLineVoltage This command is used to get the line None elnforms_LineVoltage eCommands_getLineCurrent This command is used to get the total None elnforms_LineCurrent eee ismu a eCommands_getLinePower
16. TT LIT C _ 2 initial Set Up Default user name and password admin admin DHCP Beginning with firmware version 2 04 281 the factory default IP Mode will be DHCP previously Static A DHCP Server will automatically assign an IP address dynamic address as well as Subnet Mask and Gateway to the Axess Elite To find the IP address of the Axess Elite you will need to use the Discover function of the DMU query your DHCP server and locate the MAC address of the Axess Elite in the DHCP server s IP MAC table or access the CLI via serial and use the get network command Command Line Interface CLI Many configuration parameters may be set using the Command Line Interface CLI The CLI is accessed through the network using a telnet client or through the serial port Open a telnet client and point it to the current IP Address of the Axess Elite The factory default telnet port is 23 Connect to the serial port The factory default settings are 9600 8 n 1 Upon connection press Enter and then enter the user name and password when prompted The factory default user name and password is admin admin These are the basic commands to set the network parameters via CLI After setting these parameters the Axess Elite will need to be rebooted for the settings to take effect Any command that requires rebooting of the Axess Elite will provide a prompt to do so All commands may be entered as required before rebooting 2015 SurgeX Ele
17. This command is used to get the total None elnforms_LinePower eCommands_getSysStatus This command is used to get the elnforms_sysStatus system status eCommands_poll This command is used to poll None elnforms_poll Expansion units 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com SURGE AXESS User Manual energy intelligence Firmware Version v2 04 281 9 6 Payloads Payload m tOutletStatus typedef struct eOutletStatus status 8 tOutletStatus typedef enum eOutlet Status_ null typedef struct eAuxStatus status 2 tAuxStatus tAuxStatus typedef enum eAuxStatus_ null eAuxStatus_ tLineVoltage typedef struct 7 ee float lineVoltage tLineVoltage tLineCurrent typedef struct ee float lineCurrent tLineCurrent tPoll typedef struct atus 2 float lineVol tage float tLinePower typedef struct float linePower tLinePower tOutletCurrent typedef struct float outletCurrent 8 tOutletCurrent 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 30 tOutletPower tSystemStatus tOutletCommand tAuxCommand tInformManualControl tInformOverVoltage tInformUnderVoltage tInformOverCurrent tInformOverTemperature tSystemStatus tOutletCommand 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com AXESS Use
18. Triggers Triggers Create and modify User Triggers Create and modify custom Sequences Create and modify Expansion units and Favorite links 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 11 Firmware Version v2 04 281 energy intelligenc SURGE AXESS User Manual 5 5 1 Device Setup The Device Setup page allows for the specification of basic device parameters Saving any change which requires a reboot to take effect will result in the addition of a Reboot Required button at the bottom of the page Device Setup tem Deo O OOS O O On Power Up Specify whether to set outlets to Initial States or run a predefined Sequence when the Axess Elite powers up or the Reset button is pushed or a soft reboot is commanded Specifies the name label to be associated with the Axess Elite Power Up Delay Specifies the amount of time in seconds by which to stagger the manual turning on of multiple Time outlets Reboot Time Specifies the amount of time an outlet is to remain off during a Reboot operation Temperature Display Specifies whether to display temperature in degrees Fahrenheit or Celsius User Accounts May Specifies whether or not a non administrative user account is allowed to manually clear a Clear Shutdown persistent shutdown state Serial Baud Rate Specifies the baud rate to be used with the serial interface Serial Port Requires Specifies whether or not a
19. ctronic Systems Protection Inc Technical Support 800 645 9721 surgex com 6 SURGE X AXESS User Manual energy intelligence Firmware Version v2 04 281 Example Telnet to DHCP Assigned IP Address 192 168 1 199 on Port 23 and change to Static IP Address 192 168 1 3 Axess ELITE Connected to Telnet Session 1 User gt admin Password gt Axess ELITE gt set ipmode static OK Axess ELITE Reboot Required gt set ipaddress 192 168 1 3 OK Axess ELITE Reboot Required gt set subnet 255 255 255 0 OK Axess ELITE Reboot Required gt set gateway 192 168 1 7 OK Axess ELITE Reboot Required gt reboot 3 Installation The SurgeX Axess Elite is designed to be installed in a 19 inch equipment rack and requires one unit 1 U of rack space Use the four screws provided with the product to secure the rack ears to the rack rails These screws can be tightened by hand and do not require tools Connect power to the unit by plugging the cord into a 120V AC 15 20 amp wall or floor receptacle Do not plug the unit into a relocatable power tap 3 1 3 2 3 3 120 Volt Connections The Axess Elite has a total of 8 receptacles Each receptacle is rated for a maximum load of 15 amps but the total load of the Axess Elite must not exceed 15 20 amps Plug the equipment cords into the receptacles as needed The receptacles are numbered 1 through 8 This same numbering is used in the control interface Ethernet Connection The RJ
20. currents of all products plugged into the Axess Elite are within the 15 20 Amp product rating Telnet and serial access use the same Command Line Interface CLI structure and syntax to configure monitor and control the Axess Elite The Axess Elite may also be monitored and controlled via SNMP and or the SDxP API and may be configured to report to a Syslog server The internal web server may be secured with Secure Sockets Layer SSL encryption Two Auxiliary Relay outputs are provided for simple control of other equipment Connection terminals are provided for each relay s Common Normally Open and Normally Closed connections Up to 16 Axess Elites can be linked together and controlled from a single web interface One master Axess Elite provides the communication to the users and receives status information from the rest of the Axess Elites in the cluster Up to 128 outlets can be controlled in this manner from one IP address Up to 16 users can be assigned administrator or user only rights plus access to specific outlets The extensive programming capabilities of the Axess Elite allow sequencing and scheduling to be set up User Triggers can be programmed to activate on an if X then do Y then do Z when no longer X basis Triggers include AC line voltage total unit current draw individual receptacle current draw temperature Net Test and Contact Closure Input Actions include turning receptacles on and off cycling a receptacle
21. er Triggers on the Triggers Setup web page 3 6 Auxiliary Relay Outputs Two auxiliary relay outputs are provided at the third Aux Relay A and fourth Aux Relay B terminal blocks Access to the Common Normally Open and Normally Closed positions is provided for each relay The auxiliary relays are controlled in the same manner as the AC outlets and may be controlled by Sequences Schedules and User Triggers 4 LED Indicators There are thirteen LED indicators located on the front panel Their function is as follows Self Test LED Indicators x Indicator si Color Description Outlets When illuminated the corresponding AC outlet is on Aux Relays When illuminated the corresponding auxiliary relay is latched Self Test Test Green When illuminated the surge suppression circuitry is When illuminated the surge suppression circuitry is functioning correctly correctly is M When illuminated the Axess Elite is in shutdown mode due to out Rien cel Kaea range line voltage current or temperature Mains When illuminated the Axess Elite is connected to a live wall or floor outlet 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 8 SURGE Y AXESS ELITE User Manual Firmware Version v2 04 281 energy intelligence 5 Web Server The web server is built around 4 pages Login Device View Global View and Setup Each page is discussed in detail below 5 1 Login
22. executing previously defined sequences and sending emails For example an action can be created to send an email if the rack temperature exceeds 950F The eight rear mounted receptacles can each be individually controlled and the current power and energy consumption of each receptacle can be obtained through the web page interface and CLI The metering includes the AC line voltage and current draw and all measurements voltage current and power are true RMS readings Thus the current draw and energy consumption of non linear electronic loads which have a power factor of less than unity will be correctly reported Located on the rear panel are the input power cord circuit breaker 15A or 20A 8 NEMA 5 15 AC outlets Serial connection DCE 9 pin D subminiature Network connection RJ 45 Temperature Sensor input Contact Closure input Auxiliary Relay A B output connections and recessed Reset button Temperature Contact Closure Auxiliary Relay A Auxiliary Relay B imme cci ccoa NO com NC NO com NC lt 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 5 SURGE AXESS LITE User Manual energy intelligence Firmware Version v2 04 281 The thirteen front panel LEDs provide indications for eight AC outlet On Off status green two Auxiliary Relay Latched Unlatched status green surge protection status green Shutdown status amber and AC mains power red Ru
23. f the SDxP manager SDxP Status Broadcast Specifies whether or not to enable a status broadcast and the frequency of the broadcast messages in minutes SDxP Event Reporting Specifies which items are accessible by the SDxP protocol SDxP Encryption Specifies whether or not to use AES encryption with a shared passphrase Syslog Port Specifies the port to be used with a Syslog server Syslog Server Specifies the IP address of a Syslog server 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 15 SURGEX AXESS ELITE User Manual energy intelligence Firmware Version v2 04 281 5 5 4 Users Setup The Users Setup page allows for the creation deletion and editing of up to 8 user accounts Each user will have a unique user name password and email address and may be assigned access to specific outlet s User accounts may be of the Asigned igh Administrator or User _ type etetetetetet ee Administrators have access to all a en functions Users do not have access to Setup functions User authentication is supported for Web Serial Telnet and SDxP interfaces s ma item i Allows for the creation of a new user account Saves the updated user information Closes the edit dialogue without saving any changes 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 16 SURGEX AXESS User Manual energy inte
24. ic Systems Protection Inc Technical Support 800 645 9721 surgex com 26 9 5 AXESS typedef enum eType_null eType_inform eType_commands eCmnd Comand Description o O eType_null gt This is a null command and should not be sent to the server eType_Informs User Manual Firmware Version v2 04 281 There are currently 2 types All classes are defined in the C programming enumerated type definition below eType_inform Informs are similar to SNMP traps They are sent from the managed device to the manager on a periodic basis Used to control and query the managed device Descriptors Descriptors are used to describe the individual commands within a command class and the payload that the packet contains All of the descriptors and their payloads are outlined by command class below Informs are similar to SNMP traps They are sent from the managed device to the manager on a periodic basis typedef enum elnform_null elnform_outletStatus elnform_auxRelayStatus elnform_lineVoltage elnform_lineCurrent elnform_linePower elnform_ouletCurrent elnform_outletPower elnform_sysStatus elnform_poll elnform_overVoltager elnform_underVoltage elnform_overCurrent elnform_overTemperature elnform_selfTestFail elnform_userTriggerClear elnform_userTriggerFail elnform_manualControl elnform_systemTriggerClear elnform 2015 SurgeX Electronic Systems Protection Inc Technical
25. ical Support 800 645 9721 surgex com 2 SURGE X AXESS User Manual Firmware Version v2 04 281 intelligenc Table of Contents 1 2 Introduction 9 Initial Set Up 6 Installation l 3 1 120 Volt Connections see 7 3 2 EthernetConnections ss eee 7 3 3 RS232 Serial PortConnection sss uuuuuIuIuIIu uu a 7 3 4 Temperature Sensor see 8 35 Contact Closure Input eee 8 36 Auxilary Relay Outputs ee 8 LED Indicators 8 Web Server 9 51 Logn 2 uruere nUUIIIII u uuuuurer r u U uuuuur o a a aa 9 5 2 Administration eee 9 5 21 ResetFactoryDefaults m 9 5 2 2 Backup Restore o y yll 9 5 23 Systemlnfo uuu L 9 5 3 DeviceView eee 10 5 4 Global View eee 11 55 Setup uuu u ura L 11 554 DeviceSetup UU CCO 12 552 NetworkSetup C 13 5 0 0 NetworkReportingSetup sss U Uuuuuuuauur III u uuuuuuuuIuIIIIu I aT 15 554 Users y Setup y y y y y eyja 16 555 Triggers Setup C uuu u uuu u a 1 17 5 0 6 UserDefinedTriggers ss uuuuuuuuuI uu u u uuu a a a 18 5 0 7 SequencesSetup UU ur ur IIIa a a 19 558 LinksSetup UU CO 20 Command Line Interface Protocol 21 6 1 Prompts ss eee 21 6 2 Syntax U uuu III III a a 21 6 3 Responses ss 21 6 4 CLI Documentation Notation _ _ _ss_ eee 21 6 5 Device Commands L 22 6 6 Network Commands 2 unan uu nanara 4 uu270 222 23 6 7 Calibration Commands 23 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 3 SURGE X AXESS Use
26. ified by the Over Temperature System Trigger Note that Over Voltage and Under Voltage shutdown events will clear automatically when the line voltage returns to an acceptable level 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 17 SURGE AXESS ELITE User Manual PPRS TAT A Dee Firmware Version v2 04 281 5 5 6 User Defined Triggers User defined triggers that have previously been created are displayed in a list The name of the 2 lt trigger is the name that was given to the trigger when it was created Pressing Test Alarm will Alarm Action Target Clear Action Target activate the trigger alarm action and pressing M how Test Clear will activate the trigger clear action U m use these test functions to verify that the trigger lt oe will operate as intended Pressing Edit will open the trigger for editing m tore and pressing Delete will delete the trigger New triggers may be created by pressing the New Trigger button Trigger Executes When Trigger Clears When Temperature High Temperature gt Set Point Temp lt Set Hysteresis Temperature Low Temperature lt Set Point Temp gt Set Hysteresis Voltage High Voltage gt Set Point Voltage lt Set Hysteresis Voltage Low Voltage lt Set Point Voltage gt Set Hysteresis Line Current High Total Current gt Set Point Current lt Set
27. lligence Firmware Version v2 04 281 5 5 5 Triggers Setup The Triggers Setup page allows for the modification of System Triggers Ta Sti Over Voltage Auto Shutdown Greater Than 150 Volts F 7 and creation of User Triggers POPEATER i i System Triggers define the protective pened eS an A a _ shutdown points for the AC Jas Tega At Suunan m 2 F outlets and take precedence over a all other actions including User REN Triggers ma usay Triggers Setup om Description Hysteresis Specifies the amount by which the associated parameter must return closer to nominal following the activation of a System Trigger for the shutdown to be considered clear For example using an over voltage shutdown point of 150V and a hysteresis of 7 The Axess Elite will enter a shutdown state when the line voltage exceeds 150V and will not leave the shutdown state until the line voltage drops below 150 7 143V Auto Shutdown Auto Shutdown Over Current Shuts off all outlets if the total current draw exceeds the set value Once this has been triggered the unit will stay Auto Shutdown in a persistent shutdown state until manually cleared by pressing Clear Shutdown on the Device View page or by issuing the CLI command clear shutdown The over current shutdown point should not be set too close to the anticipated normal operating current draw as this could cause an inadvertent shutdown May be disabled Over Sh
28. lt 1 99 gt Sets the Reboot Time in seconds No 5 No No I No Yes 2 Yes 9600 No Yes Y No Yes Y Yes set factory defaults Resets all parameters except Network Settings to their factory default settings Yes or a i Confirmation is required Note This command may take up to 30 seconds to execute Ends the session No No 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 22 SURGE AXESS 6 6 Network Commands User Manual Firmware Version v2 04 281 Command Description Admin FatDf Returns the network settings Ye J o assasi gelmac Returns the MAC address of the network adapter set ipmode lt static dhcp gt Sets the IP Mode set ipaddress lt dotted decimal gt Sets the IP Address in dotted decimal the IP Address in dotted decimal Yes set subnet lt dotted decimal gt Sets the subnet mask in dotted decimal Sa aa a ded e Yes DHCP DHCP Assigned 255 255 255 0 set gateway lt dotted decimal gt Sets the gateway in dotted decimal 0 0 0 0 ws set dns1 lt dotted decimal gt Sets the DNS server 1 address _set dns2 lt dotted decimal gt Sets the DNS server 2 address III I Yes Set web http port lt 1 65535 gt Sets the web server port o j Yes 8 set telnet port lt 1 05535 gt Sets the telnet port 6 7 Calibration Commands Yes Command Description Admin Standard Value set vol
29. mmand Description Standard Syntax This command is used to change a parameter set lt variable gt lt specifier gt Set This command is used to return the value of a parameter get lt variable gt This command adds an entry row to any array of variables add lt array gt lt newentry gt This command renames an entry in an array ren lt array gt lt oldname gt Del This command deletes an entry from an array del lt array gt lt entryname gt 6 3 Responses 6 4 CLI Documentation Notation Description Text without brackets Items you must type as shown lt Text inside angle brackets gt Placeholder for which you must supply a value Hyphen Range of acceptable numeric values Vertical Bar Separator for mutually exclusive items choose one 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 21 SURGE Y AXESS User Manual Sau intelligence Firmware Version v2 04 281 6 5 Device Commands Command Description Admi Fact Def Returns the status of the specified outlet AC outlets are numbers 1 8 Aux Relays No get outlet lt 1 10 gt A and B are numbers 9 and 10 Sets the selected outlet to the selected state The user must have rights to No set outlet lt 1 10 gt lt on off reboot gt the selected get devicename Returns the device name No Axess ELITE set devicename lt devicename gt Sets the device name Yes get reboot Returns the Reboot Time No set reboot
30. ple Axess Elite and Axess Ready units on a local network Display the current IP address of each unit Allows the settings of a new IP address for each connected device Return a connected Axess Elite or Axess Ready device to Factory Defaults The Device Management Utility is available for download at http Awww surgex com products Axess ELITE html Note The IP address can only be set within the first 2 minutes after powering up the Axess Elite The utility will only work with an Axess Elite on the same local subnet as the PC Device Discover Automatically discover all Axess Elite products on the network The DMU will display the location name of the unit the product ID and version number the current IP address and the MAC address Factory defaulted Axess Elites will display with the name Axess Elite and network settings will not be affected Add Manually add an Axess Elite by IP address Clear Clear the list Set IP Address Changes the IP address of the selected Axess Elite Factory Defaults Return the selected Axess Elite to a Factory Default state This action must be performed within the first 2 minutes after powering up the unit Local Address Select the IP address to Discover on This may be necessary for computers with multiple network connections 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 32 SURGE lt AXESS EL User Manual 11 12 13 intelligence Firmware Version
31. r Manual Firmware Version v2 04 281 typedef struct float outletPower 8 tOutletPower typedef struct eOutletStatus outletStatus 8 eAuxStatus auxStatus 2 float lineVoltage float line Current float linePower typedef struct U8 outlet eOutletStatus status tOutletCommand typedef struct char relay tAuxCommand 11 8 IIA or B eAuxStatus IIN or F typedef struct unsigned char outlet change unsigned char status State to change to typedef struct float voltage tInformOverVoltage typedef struct float voltage tInformUnderVoltage typedef struct float current tInformOverCurrent fid of outlet to lithe typedef struct int temperature tInformOverT emperature typedef struct eOutletStatus outletStatus 8 eAuxstatus auxStatus 2 float typedef struct U8 outlet 11 8 eOutletStatus status tOutletCommand 31 SURGE AXESS User Manual energy intelligence Firmware Version v2 04 281 10 typedef struct char relay IIA or B eAuxStatus IIN or F tAuxCommand tAuxCommand typedef struct unsigned char outlet id of outlet to change unsigned char status IIthe state tInformManualControl typ ed ef Device Management Utility The Device Management Utility DMU is compatible with SurgeX Axess Elite Axess Ready products and provides the easiest means to find and configure your Axess Elite unit to Automatically discover multi
32. r Manual energy intelligence Firmware Version v2 04 281 7 EmailNotification 8 SNMP 9 SDxP Protocol 9 1 Overview 10 Device Management Utilit 11 Sysloc 12 Rear Panel Reset Button 13 Firmware Upgrade 13 Specifications 33 33 34 39 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 4 SURGE AXESS User Manual energy intellige Firmware Version v2 04 281 1 Introduction The SurgeX Axess Elite is a single rack space 120V 15 20 amp AC power conditioner that can be controlled over a network or the internet through a direct serial connection or through a contact closure input The simple web server structure allows basic control of the outlets and viewing of status information all from the home page The extensive programming and setup capabilities are accessed in seven other pages or through a Command Line Interface CLI The Axess Elite incorporates SurgeX Advanced Series Mode power conditioning and surge elimination Surgex Impedance Tolerant EMI RFI filtering and SurgeX ICE Inrush Current Elimination circuitry on receptacles 1 and 2 SurgeX ICE eliminates problems associated with inrush currents from large loads such as amplifiers With SurgeX ICE it is not necessary to take inrush currents into account when designing the AC power for a system Special time delay circuit breakers are not required it is necessary only to ensure that the average
33. remented by the client and server with each correct packet sent Example Client Server hello 000 1234 seq 1234 Command seq 1235 Command gt seq 1237 Response 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 25 SURGE AXESS User Manual energy intelligence Firmware Version v2 04 281 9 3 SDxP Packet The packet is broken up into 2 parts the Header and the Payload Header The header is used to carry general information such as is shown in the C programming structure below typedef struct eType type char 21 uName char 21 password uChar desc uChar param uint16 seq THeader Variable Description O O O O S S subsection for a full list of packet types uName password desc This variable is the type descriptor that describes the type of data that is being sent By extension it lets the server know what the payload is There is a different set of descriptors for each type class See the Descriptors subsection for a full list of descriptors by type Reserved for future use Optional parameter that may be passed to the server in addition to the descriptor The packet s sequence number Used as part of the security scheme Payload The payload is determined by a combination of the type class and the descriptor The payloads are described by the descriptor see the Descriptors subsection for details 2015 SurgeX Electron
34. serial CLI session requires login Login Auto Logout Specifies the web and telnet security timeout in minutes Use History Logging Specifies whether or not to keep an internal log file Allow Firmware Upgrade Specifies whether or not the Axess Elite is in an upgradeable state Outlet Name Allows for the specification of name labels for each outlet Initial State Specifies the state the outlet will take following a loss of power or the clearing of a shutdown event Specifies whether or not to activate Inrush Current Elimination for outlets 1 and 2 On Shutdown Clear Specify whether to set outlets to Initial States or run a predefined Sequence when a Shutdown State clears Aux 1 Confirmation Enables disables Confirmation Mode for Aux Relay 1 wherein Aux 1 will be latched only when all AC outlets are On 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 12 SURGE Y AXESS ELITE User Manual energy intelligence Firmware Version v2 04 281 9 5 2 Network Setup The Network Setup page allows for the specification of network settings including the network adapter email and time keeping Saving any change which requires a reboot to take effect will result in the addition of a Reboot Required button at the bottom of the page ONS 1 O 42 2 ONS 2 209 11684 1410 Wee HTTP Pon po Web HTTPS Port a sarum anet Tenet Por natse Erman Tuma Zone Ofset Use DST DST Start Date 2
35. staggered by the Delay time Turns the selected outlets off Turns the selected outlets off for the length of the Reboot Time and then back on Displays the internal history log if enabled 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 10 SURGEX AXESS ELITE User Manual energy intelligence Firmware Version v2 04 281 5 4 Global View The Global View page displays the current outlet states and system status for the Axess Elite and expansion units Up to 15 expansion units may be set up on the Links Setup page Device namo 1 2 s 7 amp ams tun Sy Stat Axess ELITE wr mr wr Sr ur wr us u OK Outlets and Aux Relays may Co Cor wes J RD sirtos as ot 077102012 tase be commanded to turn On Off or Reboot for up to 16 Axess Elite units 1 master and 15 expansions In order to have rights to control expansion unit outlets the user s identical user name and password must be programmed into each expansion Axess Elite to be managed 5 5 Setup Complete setup and configuration of the Axess Elite is provided via 7 Setup web pages Each setup page is described in the following sections Setup Setup Page Description Device Configure basic device parameters Network Configure network settings including the network adapter email and time keeping Network Reporting Configure SNMP SDxP and Syslog reporting Configure user accounts Configure System
36. tage calibration lt 105 130 gt Sets the voltage calibration AC Volts set voltage offset lt 0 130 gt Zeroes the voltage calibration AC Volts Ye O set current lt 1 8 all gt calibration lt 1 205 Sets the individual outlet current calibration AC Amps Yes set current lt 18 all gt offset lt 20 20 gt Zeroes the individual outlet current calibration AC Amps Yes 0 set power lt 1 8 all gt calibration lt 1 2400 gt Sets the individual outlet power calibration AC Wats Yes set power lt 1 8 all gt offset lt 20 20 gt Zeroes the individual outlet power calibration AC Walls Yes 0 set temperature offset lt 999 999 gt Sets the temperature calibration offset Degrees F 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 23 SURGEX AXESS ELITI User Manual energy intelligence l Firmware Version v2 04 281 Email Notification Email can be automatically sent for System Triggers and User Triggers Emails generated by the Axess Elite will display the device name and information related to the System Trigger or User Trigger Examples Subject Axess ELITE Cabinet_1 Date Sat 7 Jul 2012 09 41 00 0500 From lt AxessElite surgex com gt To networkadmin yourco com Axess ELITE Cabinet_1 at 192 168 1 199 System Trigger Over Temperature at 115 degrees Alarm Subject Axess ELITE Cabinet_3 Date Sat 7 Jul
37. the command set password lt password gt may be used to assign a new admin password While in this mode the red Mains LED will flash 0 5 seconds on off Holding the reset button for 5 seconds or longer while powering up the unit will enter factory default reset mode When the button is released the unit will be reset to factory defaults including Network Settings Firmware Upgrade Refer to the Firmware Upgrade Utility user manual at htto www surgex com products Axess ELITE html for details 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 33 SURGE AXESS User Manual energy intelligence Firmware Version v2 04 281 14 Specifications Parameter Specification Load Rating 15 20 Amps at 120 Volts SX AX15E SX AX20E Power Requirement no load Watts Surge Let through Voltage 6000 Volt Surge Volts O Oo ep ep ep C CD WN OD O ep ep lt o r Ww oO ep v gt 3 op gJ oOo gt D 3 Op Q WN Op O cO oO O UL 1449 Adjunct Classification Test Results uppressed voltage 170 Volts no failures aximum Applied Surge Voltage 000 Volts nlimited due to current limiting nlimited due to current limiting C aximum Applied Surge Current x aximum Applied Surge Energy Endurance C62 41 1991 category B3 pulses 1 KV gt 500 000 3 KV gt 10 000 6 KV gt 1000 Normal mode 50Q load Q WO A L
38. uts off all outlets if the temperature sensed by the external temperature sensor exceeds the set value Once Temperature this has been triggered the unit will stay in a persistent shutdown state until manually cleared by pressing Auto Shutdown Clear Shutdown on the Device View page or by issuing the CLI command clear shutdown May be disabled Self Test Failure Shuts off all outlets in the unlikely event that the internal surge protection circuitry fails Auto Shutdown Once this has been triggered the unit will stay in a persistent shutdown state until manually cleared by pressing Clear Shutdown on the Device View page or by issuing the CLI command clear shutdown May be disabled Persistent The Axess Elite will enter a Persistent Shutdown State upon registering an Over Current Over Temperature or Shutdown State Self Test Failure event While in this state all 8 receptacles will be turned Off and the front panel amber LED labeled Shutdown will be illuminated Outlet control will not be restored until the shutdown is manually cleared by pressing one of the Clear Shutdown buttons located on the Device View page or by issuing the CLI command clear shutdown Before clearing the shutdown state it is advised to verify that the combined current requirement of all equipment powered by the Axess Elite is less than the value specified by the Over Current System Trigger and that the measured temperature is less than the value spec
39. which will be available for monitoring and control on the Global View page of the master unit Up to 15 Expansion units may be defined Favorites may be any internet address Use Favorites to set up shortcuts to earlier versions of the Axess Elite product other equipment web servers or Internet web pages Axess ELITE Expansion IP Address Sma Addresses may be specified with a port number in this format http IPADDRESS PORTNUMBER for example http 192 168 1 199 72 Saved Expansions and Favorites are available in the Links subsection of the Device View page 2015 SurgeX Electronic Systems Protection Inc Technical Support 800 645 9721 surgex com 20 SURGEX AXESS User Manual energy intelligence Firmware Version v2 04 281 6 Command Line Interface CLI Protocol The Command Line Interface provides complete setup of all functions of the Axess Elite The CLI may be accessed either via the network interface using Telnet or via the serial port using a terminal emulator program Some commands of the CLI require administrative rights these are indicated in the following tables 6 1 Prompts User gt Prompt to enter a valid User Name Not case sensitive Password gt Prompt to enter the Password associated with the User Name Case sensitive Axess ELITE gt Standard prompt while logged in Axess ELITE Reboot Required gt Prompt after making a change which requires a reboot to take effect 6 2 Syntax Co