1. Freephone 1800 121 535 Fax 1800 121 533 E mail enquiry skope com au Website www skope com au Trademark Infringement The SKOPE trademark on this product is infringed if the owner for the time being does any of the following e Applies the trade mark to the product after their state condition get up or packaging has been altered in any manner e Alters removes including part removal or obliterates including part obliteration the trade mark on the product e Applies any other trade mark to the product e Adds to the product any written material that is likely to damage the reputation of the trade mark Notice of the above contractual obligations passes to e Successors or assignees of the buyer Future owners of the product TME Series SKOPE Vertical Chiller User Manual MAN10259 Rev 3 0 Oct 2013 2011 SKOPE Industries Limited All rights reserved SKOPE Industries Limited reserve the right to alter specifications without notice SEKOPE is a registered trademark of SKOPE Industries Limited
2. marked POWER or similar 6 Refit the pillar cover by squeezing and snapping the pillar into place on the back of the cover as you work down the length of the light 7 Fix the pillar in place with the fixing screw at the bottom of the pillar Sign Light The sign unit is lit by one T8 LED tube which can be replaced by removing the front sign panel See the sign light specifications for each model in the table below Model LED Light Specifications TME650 9 Watt T8 LED Tube 26 x 600mm TME1000 12 Watt T8 LED Tube 226 x 900mm TME1500 24 Watt T8 LED tube 226 x 1500mm To replace the sign light 1 Disconnect the chiller from the power supply Notch 2 Start at one of the top corners of the sign unit and pull the sign panel out from under the sign top cover 3 Work along the length of the sign unit pulling the sign panel out as you go 4 Carefully remove the sign panel from the sign unit 5 The tube can now be accessed for replacement Rotate the failed tube until the pins on the end of the tube align with the slots then slide it out 6 Fit the new tube and rotate until it clicks into position Sign Top Cover 7 Refit the sign panel When refitting Corner Notch the sign panel ensure both sign panel end strips fit neatly into the top Sign Panel and bottom corner notches End Strip Sign Panel 10 Servicing User Manual Servicing User Manual Troubleshooting SKOPE TME Series For
3. problems with the chiller and refrigeration unit use the following table Problem Possible Cause Suggestions Chiller not operating Check mains power supply supply e Interior light not on Failed LED tube e Blown chiller fuse Power consumption Unit operating too is higher than hot expected chiller doors are opened excessively Product is too warm Restricted airflow to chiller e Warm chiller e Blocked condenser temperatures Compressor Poor ventilation operating for long around refrigeration periods more than 1 unit hour Replace LED tube see page 9 Contact an authorised service agent to replace it Clean the condenser coil see page 8 Ensure the chiller has good ventilation around the refrigeration unit see page 5 Ensure the chiller is in a cool spot Ensure doors are closed more often Ensure product is not blocking airflow slots Ensure there is space around individual product pieces e Clean the condenser coil see page 8 Ensure the chiller has good ventilation around the refrigeration unit see page 5 11 SKOPE Contacts SKOPE Industries Limited NEW ZEALAND CONTACT Head Office PO Box 1091 Christchurch New Zealand Freephone 0800 947 5673 Fax 03 983 3896 E mail enquiry skope co nz Website www skope co nz AUSTRALIAN CONTACT A B N 73 374 418 306 PO Box 7543 Baulkham Hills B C NSW 2153 Australia
4. User Manual MAN10259 Rev 3 0 Oct 2013 TME Series SKOPE Vertical Chiller TME1000 SKOPE Refrigeration SKOPE Warranty Protection To activate your Warranty Protection you Must register your product with SKOPE within 4 weeks from date of invoice To register online EN Visit our website at www skope com warrantyprotection p mabe then complete and submit the online registration form Or alternatively contact our Customer Services team to register 1800 121 535 Australia 0800 947 5673 New Zealand SKOPE 1 year Extended Warranty Extend your Warranty Protection by 1 year during registration Please check you have not already organised an extended warranty through your dealer at time of purchase For pricing information on an extended warranty visit www skope com warrantyprotection Service amp Support We know you will get years of satisfaction from your new SKOPE product when you follow a few simple preventative maintenance guidelines Helpful information is available on our website Ono www skope com serviceandsupport 3 Thank you for purchasing a SKOPE refrigeration product SKOPE TME Series Service Manual CONTENTS 1 Installation Safety First ll sneen ee ee 4 Positioning the chiller 0 0 0 0 0 cee 5 Power COM suck Iq meer le Send HR Pd nd op en E Roi as 5 Chiller Location llle nen 5 MENU OR E 5 Fitting the Illuminated Sign 2 0 0 ce
5. e less power and last longer Allow adequate space for door s to open and close properly Self closing doors have internal torsion bars pretensioned at the factory and must be unobstructed Ensure the chiller sits on a level surface so that the door s shut and correctly seal Level footing also prevents the condensate tray from overflowing The maximim recommended ambient temperature for the chiller is 32 C For effecient operation of the chiller it is essential that adequate ventilation be provided above the refrigeration unit Ensure there is always at least a 200mm gap abetween the top of the sign panels and ceiling Never store cardboard cartons or other objects on top of the chiller IMPORTANT To ensure effecient and reliable operation a minimum of 200mm clear ventilation space is required above the refrigeration unit SKOPE TME Series Fitting the Illuminated Sign When supplied the illuminated sign is packed inside the chiller for transit purposes To fit the illuminated sign 1 Loosen the four retaining screws on top of the chiller and fit the left and right hand ventilated sign sides in position Slide the panels forward flush with the edges of the chiller and tighten the screws Sign Side 2 Clip the sign back panel Pang into retaining slots on the rear of the sign sides and tighten fixing screws Sign Back Panel 3 Fit sign assembly by engaging clips into both retaining slots on the fr
6. een 6 Fitting the Shelves 0 0 eee eee 6 2 Operation las cd aes ooo oe Oe a bee ae eee een een 7 Loading Product o eu to ne an ae E fot di pt Ge a dert eres 7 3 Servicing CIGQNING an en ERRORI EE ne eee he RE Es rid dd eed 8 ejl 8 Condenser Coil clle 8 LIONING ec cee pod wows 5 UE ees eee enn GS ONE HE SE YE 9 Interior Light u acc iom 00 4 et Rn Re Re ae ee a 9 SGN LIOR se are ses om aed Sees nee we a ed Ge Roe ee me eee 10 Troubleshooting 0 0 000 cc eee eee 11 SKOPE TME Series 1 Installation Safety First Always observe safety precautions when using any electrical appliance Read these instructions carefully and retain them for future reference o When the appliance is used by or near young children or infirm persons close supervision is necessary especially to ensure children do not play with it Do not use this appliance for other than its intended use Do not cover the grilles or block the entry or exhaust of airflow by placing objects up against the refrigeration cassette Do not probe any opening Only use this appliance with the voltage specified on the chiller rating label affixed to the refrigeration cassette o Ensure the chiller has adequate ventilation as this is essential to economical high performance Be careful not to touch moving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised per
7. king any service or maintenance work chiller Periodically wipe the inside and outside of the chiller with a damp cloth taking care to keep moisture away from electrical parts As with any maintenance ensure the chiller is isolated from the power supply before cleaning Condenser To ensure trouble free performance the condenser coil must be cleaned Coil each month with a soft brush or vacuum cleaner to remove any dust or blockage from the coil fins A more thorough cleaning is recommended every six months by qualified service personnel To clean the condenser coil 1 Disconnect the chiller from the power supply 2 Loosen the sign retaining clip on the top edge of each sign panel and lift the sign unit up to disengage from the sign sides 3 Disconnect the sign plug from the electrical box socket and remove the sign unit from the chiller 4 The condenser coil is now accessible for cleaning Servicing User Manual SKOPE TME Series Lighting This chiller is designed for use with LED tubes and is not compatable with fluorescent tubes IMPORTANT DO NOT use fluorescent tubes Interior Light Depending on the model the chiller will have either one or two interior lights Servicing User Manual Rotate the LED tube until Fit a new LED tube Prop the doors open and Unclip and detach the which can be replaced without moving shelves or removing product Refer to the table below for light tube specifica
8. ont of each side panel and pull sign assembly firmly down 4 Turn the sign retaining clips on top of each side panel to hold sign unit firmly in position 5 Connect the sign ENSTO 3 pole plug into the roof top power supply socket Fitting the Shelves The chiller is supplied with five layers of shelves which may be positioned at different heights to suit various products Each shelf is held in place with four shelf clips which engage in the shelf support strips The support strips are marked with a for easy location of shelf clips To fit the wire shelves 1 Unpack the shelves and shelf clips from inside the chiller 2 Establish the desired position for the shelves and securely engage a shelf clip in each of the shelf support strips 3 Sit the shelves on the shelf clips Installation User Manual 2 Operation SKOPE TME Series Operation User Manual Start Up After the chiller has been positioned in a suitable place plug it in and check the following activity Note After moving the chiller allow the chiller to stand for at least 30 minutes before connecting to the power supply Item Lighting Thermostat Compressor Condenser and Evaporator Fans Activity The lights that illuminate the top sign and chiller interior will come on when the chiller is turned on The thermostat is pre set to give an internal air temperature of between 2 C and 4 C and under normal circumstance
9. s should not require adjustment If you do need to adjust the temperature turn the thermostat shaft protruding from the control box mounted on top of the refrigeration unit To make the temperature colder turn the thermostat clockwise To make the temperature warmer turn the thermostat anti clockwise The compressor and evaporator and condenser fans should all operate continuously from the time the chiller is plugged in This may be verified by listening for compressor switch on and checking for air movement inside the chiller The compressor and condenser fan should switch off when the chiller internal temperature reaches approximately 2 C and on again at approximately 4 C The internal chiller air will continue to circulate at all times Loading Product The chiller should be left running for 30 minutes before loading with product When loading the chiller shelves with product Allow adequate air space around each item to ensure even cooling and efficient operation of the chiller Do not exceed a maximum load of 20kg per shelf Remove some product if the shelves are flexing Do not let anything overhang the shelves because this might stop the doors from shutting or even break something SKOPE TME Series 3 Servicing Cleaning Ensure the chiller is disconnected from the power supply before cleaning WARNING Twin unit chillers have two separate power supplies Ensure both supplies are disconnected before underta
10. sonnel n Ifthe power supply flexible cord becomes damaged it must be replaced by an authorised service agent or similarly qualified person in order to avoid a hazard n Ensure all necessary safety precautions are observed during installation or removal of the refrigeration cassette o Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance a his appliance is not designed to be stable while in motion Use extreme caution when moving or transporting the appliance n Please contact SKOPE customer services for advice regarding disposal of this appliance WARNING Always disconnect the chiller from the mains power supply before attempting any cleaning or maintenance CAUTION Never overload the power supply which could damage the chiller and product See the rating label inside the chiller for the safe power supply and current draw 4 Installation User Manual Power Cord Chiller Location Ventilation Installation User Manual SKOPE TME Series Positioning the chiller The chiller has a flexible power cord fitted with a 3 pin plug which exits below the rear sign panel Pull the power cord around so that it s not trapped before you position the chiller The location of the chiller may be the single most important decision that will extend its life and ensure economical high performance We recommend that you put the chiller in the coolest place possible because it will us
11. tions Interior light specifications Model LED Tube Specification TME650 1 x side light 22 Watt T8 LED tube 26mm x 1500mm TME1000 2 x side lights 22 Watt T8 LED tube 226mm x 1500mm TME1500 2 x pillar lights Twin 24 Watt T8 LED tube 26mm x 1500mm To replace a chiller interior side light Disconnect the chiller from the power supply 2 Remove the diffuser by squeezing it until it is released from the housing and then push the diffuser out of the way the pins on the ends of the tube align with the slots then slide it out Ensure the LED tube is fitted with the power end at the top usually marked POWER or similar E Il iu INI IB di i 4 Refit the diffuser by slipping the back section into the housing then squeezing and snapping the front section of the diffuser into place as you work down the length of the light To replace a chiller interior pillar light Disconnect the chiller from the power supply remove the fixing screw from the bottom of the e pillar cover pillar cover down the length of the pillar to access the LED tube Take care not to tug or damage wires when detaching the cover Continued over page SKOPE TME Series 4 Rotate the LED tube until the pins on the ends of the tube align with the slots then slide it out 5 Fit anew LED tube Ensure the LED tube is fitted with the power end at the top usually

Download Pdf Manuals

image

Related Search

Related Contents

8196098 - Frymaster  BFP - QUARTA 3 Client Interface - User Manual  Intro to ARM Cortex-M3 processor and LPC1768  説明書 - ナテック  Solaris FCA Utilities Version 1.08.2 User Manual  NC100 Fuser Service Manual  De'Longhi DCH7093ER Instruction Manual  Fujitsu Handydrive IV-320  Potlatch (1954-1957) - Les Classiques des sciences sociales  Philips AS111  