Home
        USER'S MANUAL
         Contents
1.   points     Pressing a button for longer period than    FACEPLATE       Programming  buttons                   7  EXPLOSION PROTECTION             5 seconds the rate of counting increases     Security code OFF  default      1    appears after entering the menu point if security code  option is off  Changing this digit to the previously determined  security code disables further programming  After exiting the    menu point the display shows   FRonl  The default security  code is    0        Pressing the two buttons simultaneously enters the menu point  and performs save and exit command     Security code ON  programming disabled  Entering the menu point  1    appears  Entering the valid    security code will enable programming  After exiting the menu    point the display shows     PRAoF Setting the security code  enter menu point and   set    835    numerical value  special functon  appears  on the display  Acknowledge with simultaneous button  pressing      1    appears   enables new security code entry   0    9999   Accept the new code with the buttons pressing  them together     Setting the decimal point position   Enter   set the position     save exit    cP Setting the value corresponding to 4mA  E Setting the value corresponding to 20mA    E  m     e    Input signal filter  adjustable between 0 3 30sec       ae  D    Not applicable    Only explosion proof transducer and explosion proof display is allowed to use in explosion proof environment   In such conditions the uni
2.  Phone  36 1 369 7575   Fax  36 1 369 8585  e mail  sales nivelco com www nivelco com          2 2 ACCESSORIES      User   s manual     Warranty sheet     Stick on measure unit label set     Stick on face plate     Assembly screw    3 TECHNICAL DRAWINGS  DIN 43650                Plug on display with pressure transmitter       4  INSTALLATION  Plug the display unit between the sensor   s connector  standard DIN 43650  and the socket with the wires connected  than fix the three parts with the assembly screw   Pay attention for the sealing between the parts     Choose the right measuring unit label from the set and stick it on in the appropriate location than stick on the faceplate positioning carefully  so that the buttons can be  used with the faceplate  too     plk5012a0600h_01 doc   1 2    5  ELECTRICAL CONNECTIONS             4 20 mA            MENU GRAPH    Measured value    o    U        24 V DC        Connect the 2 conductor  cable to the DIN socket  after disassembling it     Lead the cable through the  gland     6  SETTING UP THE DISPLAY    The displayed values must be adjusted to the  4 20mA loop current that flows through the unit   scaling process   This is done via the two buttons on  the faceplate   UNICONT PLK 501 display offers numerous set up  menu points     Entering the configuration menu and navigating  among the menu points is done by the up and  down arrow buttons     Pressing the two buttons simultaneously does  entering and returning saving from the menu
3.  as transport costs  Nivelco shall not be liable for misapplication  labour claims  direct or consequential damage or expense arising  from the installation or use of equipment     plk5012a0600h_01 doc   2 2    plk5012a0600h_01 doc  2009  July 14     Nivelco reserves the right to change technical specifications without notice     
4. Thank you for choosing a NIVELCO instrument   We are sure that you will be satisfied throughout its use     UNICO Na    PLK 501  PLK 501 Ex  UNIVERSAL PLUG IN DISPLAY       1  APPLIACTION   UNICONT PLK 501 is a universally applicable plug in process display  It is available in explosion proof   intrinsically safe version  too  The display is designed for 4   20 mA transmitter loop connection without the  need of external power supply  The displayed numerical values can be freely scaled to the current input by  the user  setting the maximum and the minimum value    The display unit is for standard two wire transmitter  DIN 43650 connection  It should be assembled between USER   S MANUAL  the sensor base and the connector socket     2  TECHNICAL DATA  2 1 GENERAL    Type UNICONT PLK 501  PLK 501 Ex    System connection 2 wire DC  Input 4    20 mA  current loop   Display 4 digit  7 62 mm LED  Set up range   1999       9999  Damping time 0 3     30 sec  Display accuracy 0 1   1 digit  Voltage drop  lt 6V  lin  25mA   Ambient temperature 0  C       70   C  Reference temperature  25   C  Over voltage 120     150 VDC  max 1 sec at 25   C   Electrical protection Class III   Explosion protection ATEX  amp  Il  1  2 G EExia IICT4  Intrinsic safety Umax  lt 28V Pmax  lt  660 mW Imax  lt  93 mA C      Electric connection DIN 43650 connector  Ingress protection IP 65 Manufacurer     NIVELCO Process Electronics Co   Dimensions 47 x 47 x 68 mm 1043 Budapest  Dugonics u  11     Weight  100gr
5. t must be fed by intrinsically safe galvanically separated power supply or connected to 4   20mA current loop through galvanical separator     8  MAINTENANCE  REPAIR    Not applicable  Not applicable    x  py m   Le       D D   aik m      Not applicable       D  a    Not applicable  Not applicable       E  D  5    iPr Read out of maximum  measured value since the last power  up  The values can be reset with  interrupting the power     Read out of minimum  measured value since the last power  up  The values can be reset with  interrupting the power     Loading factory default  settings  Enter the menu  point  enter the number    729    and  press the two buttons together   appears and pressing the  buttons together loads the factory  default settings except for the security  code     The device does not require routine maintenance  In case dust adheres to the face of the device the faceplate can be cleaned  Repairs during or beyond the warranty    period are carried out solely by the manufacturer in the factory     9  STORING CONDITIONS    Environmental temperature range   25  C    80  C    10  WARRANTY    All Nivelco products are warranted free of defects in materials or workmanship for a period of two years from the date of purchase  The warranty is valid only with the  warranty card and the purchase invoice together  Repairs   under guarantee or not   are carried out at the Manufacturer s premises The Purchaser is liable for costs of  dismantling and re installation as well
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Express 4110-4120 User Manual  NOMENCLATORE TARIFFARIO PROTESI GAZZETTA UFFICIALE N  COSCON MOBILE IPHONE版使用手册 - COSCON eBusiness  Enterprise Advantage  SYNTHÉTISEUR NUMÉRIQUE ` MANUEL D`UTILISATION  uso utente IL1-IL3 COSTAN:uso utente Slide Costan.qxd.qxd  GH-UFD2GFー 取扱説明書 Ver- ー-00 対応08  Genius SP-i320  Palsonic TFTV663R User's Manual  Polycom CX 700 User Guide    Copyright © All rights reserved. 
   Failed to retrieve file