Home

Tango Device Server User's Guide

image

Contents

1. e J ele S t EIL ee Device CHROTRON yan a oN Server ESRF Novelec MCCE 2 Electrometers User s Guide MCCE2Electrometers Class Revision release_2_0 2 Author xavela Implemented in C Introduction This class allows you to control all MCCE 2 Novelec electrometers through a Serial bus Supported types Novelec Electrometers MCCE2 Class Inheritance e O MCCE 2Electrometers Properties Device Properties Property name Property type Description CommunicationLinkName Tango DEV_STRING ommunication The name of the device which manage the ElectrometerType Tango DEV_USHORT The elctrometer type number gt for Type 1 Novelec model 1 Device Properties Default Values Property Name Default Values CommunicationLinkName No default value ElectrometerType No default value There is no Class properties Attributes Scalar Attributes Attribute name Data Type electrometerChannel MCCE2 electrometer have two channels to support two amplifiers WARN default is 0 please set this value first Commands DEV_USHORT Device Commands for Operator Level Command name Argument In Argument Out Init DEV_VOID DEV_VOID State DEV_VOID DEV_STATE Status DEV_VOID CONST_DEV_STRING RangeUP DEV_VOID DEV_VOID RangeDOWN DEV_VOID DEV_VOID SetZeroVF Function DEV_VOID DEV_VO
2. the caller Argin DEV_VOID none Argout CONST_DEV_STRING Status description Command allowed for 4 RangeUP Description Up the range of the electrometer Throw electrometer ElectrometerException if the range limit is reached Tango DevFailed if the command cannot be performed Argin DEV_VOID no argin Argout DEV_VOID no argout Command allowed for 5 RangeDOWN Description Down the range of the electrometer Throw electrometer ElectrometerException if the range is negative Tango DevFailed if the command cannot be performed Argin DEV_VOID no argin Argout DEV_VOID no argout Command allowed for 6 SetZeroVFFunction Description Enable the Zero V F MCCE2 mode Argin DEV_VOID no argin Argout DEV_VOID no argout Command allowed for 7 SetOffsetZeroV1Function Description Enable the Offset or Zero V1 MCCE2 mode Argin DEV_VOID no argin Argout DEV_VOID no argout Command allowed for 8 SetLeakageZeroV2Function Description Enable the Leakage or Zero V2 MCCE2 mode Argin DEV_VOID no argin Argout DEV_VOID no argout Command allowed for 9 SetTestFunction Description Enable theTest MCCE2 mode Argin DEV_VOID no argin Argout DEV_VOID no argout Command allowed for 10 SetMeasureFunction Description Enable the Measure MCCE2 mode Argin DEV_VOID no argin Argout DEV_VOID no argout
3. Command allowed for 11 MCCE2_ON Description Enable the MEASURE function Argin DEV_VOID no argin Argout DEV_VOID no argout Command allowed for 12 MCCE2_ OFF Description Disable the MEASURE function Argin DEV_VOID no argin Argout DEV_VOID no argout Command allowed for 13 Local Description Enable local keyboard and Key Argin DEV_VOID no argin Argout DEV_VOID no argout Command allowed for 14 Remote Description Disable MODIFY and the ON OFF keys Argin DEV_VOID no argin Argout DEV_VOID no argout Command allowed for 15 Reset Description Restart the MCCE 2 Argin DEV_VOID no argin Argout DEV_VOID no argout Command allowed for 16 ClearRegisters Description Clear error s Argin DEV_VOID no argin Argout DEV_VOID no argout Command allowed for 17 GetRange Description Returns the electrometer range Argin DEV_VOID no argin Argout CONST_DEV_STRING The actual electrometer range Command allowed for 18 SetRange Description Apply the specified argin range on the electrometer if well formatted Else an exception is thrown Argin DEV_STRING The range to apply on the electrometer Argout DEV_VOID no argout Command allowed for 19 GetMode Description Returns the electrometer mode which can be one of the following values MEASURE V F Zero OFFSET LEAKAGE or T
4. EST Argin DEV_VOID no argin Argout CONST_DEV_STRING The electrometer mode MEASURE LEAKAGE Command allowed for 20 GetPolarity Description Returns the electrometer polarity which can be POSITIVE or NEGATIVE Argin DEV_VOID no argin Argout CONST_DEV_STRING The electrometer polarity Command allowed for ESRF Software Engineering Group Device Server efit SLE Novelec MCCE 2 Electrometers User s Guide MCCE2Electrometers Class Revision release_2_0_2 Author xavela Implemented in C Introduction This class allows you to control all MCCE 2 Novelec electrometers through a Serial bus Supported types Novelec Electrometers MCCE2 Class Inheritance e O MCCE 2Electrometers Properties Device Properties Property name Property type Description CommunicationLinkName Tango DEV_STRING ommunication The name of the device which manage the ElectrometerType Tango DEV_USHORT The elctrometer type number gt for Type 1 Novelec model 1 Device Properties Default Values Property Name Default Values CommunicationLinkName No default value ElectrometerType No default value There is no Class properties Attributes Scalar Attributes Attribute name Data Type electrometerChannel MCCE2 electrometer have two channels to support two amplifiers WARN default is 0 please set thi
5. ID SetOffsetZeroV1Function DEV_VOID DEV_VOID SetLeakageZeroV2Function DEV_VOID DEV_VOID SetTestFunction DEV_VOID DEV_VOID SetMeasureFunction DEV_VOID DEV_VOID MCCE2_ON DEV_VOID DEV_VOID MCCE2_OFF DEV_VOID DEV_VOID Local DEV_VOID DEV_VOID Remote DEV_VOID DEV_VOID Reset DEV_VOID DEV_VOID ClearRegisters DEV_VOID DEV_VOID GetRange DEV_VOID CONST_DEV_STRING SetRange DEV_STRING DEV_VOID GetMode DEV_VOID CONST_DEV_STRING GetPolarity DEV_VOID CONST_DEV_STRING 1 Init Description This commands re initialise a device keeping the same network connection After an Init command executed on a device it is not necessary for client to re connect to the device This command first calls the device delete_device method and then execute its init_device method For C device server all the memory allocated in the nit_device method must be freed in the delete_device method The language device desctructor automatically calls the delete_device method Argin DEV_VOID none Argout DEV_VOID none Command allowed for 2 State Description This command gets the device state stored in its device_state data member and returns it to the caller Argin DEV_VOID none Argout DEV_STATE State Code Command allowed for 3 Status Description This command gets the device status stored in its device_status data member and returns it to
6. s value first Commands DEV_USHORT

Download Pdf Manuals

image

Related Search

Related Contents

Notice d`utilisation - Campingcar  V, VJR, VL e VLS  CONTENIDO Pág. 1. OBJETIVO - Superintendencia de Industria y  Kingston Technology ValueRAM KVR16LR11D8/4 memory module  Bref mode d`emploi bouilloire CHÁ - Migros  New Brunswick Galaxy CO2 Incubator 14S Operations  APPAREIL D`ESSAI POUR BOYAUX DELTA HYDRO  Brochure ROLLANT Presses à balles rondes  Sandberg S-Video+audio->Scart 1.8m  Bennett Marine ES2000 User's Manual  