Home
USER MANUAL - Matthieu Benoit
Contents
1. The checksum is displayed as three figures a The sum of unsigned bytes in the memory range with the carry being added to the MSB of the checksum b The complement of a c The arithmetic negative of a NOTE The memory area can be larger than the size of the opened data file If there is a discrepancy between the expected and calculated checksums recalculate specifying the start and end address of the file 6 3 6 Buffer display modes The contents of the buffer can be displayed in 8 bit HEX 8 bit OCTAL 12 bit 16 bit storage LSB low address or 16 bit mode LSB low address To change the display select OPTIONS DISPLAY MODE and select the display mode required 6 3 7 Printing the data contents A print out of all or part of the data memory contents can be obtained by selecting DATA PRINT Specify the start and end addresses of the block to be printed and the name of the output device e g LPT1 6 4 Reading and checking devices This section explains how to read the contents of a programmed device verify the contents against known data check the device signature and identify a device from its signature and perform illegal bit checks and blank checks on devices 6 4 1 Reading a device menu as described in section Q To read the contents of a device select the correct device name from the DEV 6 1 and place the device to be read in the prog
2. Once the contents of a device have been read they can be edited using the DATA EDIT option and then saved to disk or programmed into another device See section 6 3 for more detail on editing data 6 4 2 Verifying the contents of a device against a file To verify the contents of the selected device s against known data first ensure that the buffer size is large enough to handle the file Then open the file against which you need to verify the data Place the device s to be verified in the programmer and select PROCESS VERIFY If the data matches the message VERIFY OK will be displayed If there is a mismatch the message will indicate the first address which has failed to verify Note The VERIFY operation is only performed on the COPY sockets It is NOT possible to verify a device in the Master socket 6 4 3 Verifying the device type Many newer devices contain Electronic Signature codes which enable you to electronically identify the device It is possible to verify a known device type against this ID code The ID code is also used by your programmer to check that the correct device type has been selected before proceeding with any process that may damage a chip However not all devices contain this ID code and the checks for electronic signature may themselves damage a device without a signature or one of a different number of pins from that expected This means that these checks cannot b
3. PCONFIG M SIGNETIC EPR N 27C64A EM Programming and verifying the device GPPROG TESTFILE HEX Example 2 This batch file has basic error checking throughout It reports a message at the end informing the user of the success or failure of the attempt to program For a complete list of errorlevels see section 8 3 Remember In DOS when errorlevels are being tested a test of errorlevel 1 will jump to fail if the errorlevel is greater than or equal to 1 ECHO OFF QE REM Setting up the environment variable to point to the ChipWriter software REM This only needs to be done once and may be done in the AUTOEXEC BAT file SET CWGANG C DATAIO CWGANG RI G EM Configuring the MoT to program Signetics 27C64A PCONFIG M SIGNETIC EPR N 27C64A LF rrorlevel oe fail REM Programming and verifying the device GPPROG TESTFILE HEX if errorlevel goto fail echo Device programmed OK goto end sfair echo Programming error end Appendix A Shorthand Keystrokes For quick operation of Data I O Programmers the following shorthand keystrokes are available CWGANG Open AlttO Save Alt S Exit Alt X Data Edit Alt E Checksum Alt C Fill Buffer Alt F Goto Address Alt G Buffer Size Alt Z Read Alt R Verify Alt V Blank Check Alt B Program Alt P Manufacturer Alt M Type Alt
4. so g0 Now that the configuration is complete switch off the programmer and remove the parallel cable If you are using a Configuration EPROM place the device in the MASTER socket If you are using the Internal EEPROM ensure that the Master socket is empty When the GLV 32 is powered up it waits to see if there is a message from the PC If no message is received it looks for a 27C512 CONFIGURATION EPROM in the Master socket If no device is present it looks in the internal EEPROM If no data is found or if there is a problem locating the Configuration EPROM the Master LED will flash three times in succession and will continue this error message until the machine is reset Once the machine has found the correct device parameters LED s 0 7 will display a code byte indicating which type of device it is configured for See section 7 6 for more information Once the code has been checked clear the display by pressing reset To program devices Place the DATA Master EPROM in the master socket then place the blank devices in sockets 0 7 Press START to begin programming While programming is taking place the indicator LED s will light for each socket in which there is a device the Master LED will flash During the VERIFY stage the master LED will remain on permanently If programming is successful a walking sequence will appear on the LED s If unsuccessful the LED s will flash to indicate which sockets have failed 5
5. DATATO CWGANG CWGANG PIF Change Working Directory to C DATAIO CWGANG Select CHANGE ICON and change the file in the CHANGE ICON prompt to C DATATIO CWGANG EPROM ICO or C DATAIO CWGANG EPROM1 ICO e Select OK enee Use Optional Parameters if required The mouse functions should work in a DOS window in 386 enhanced mode in Windows 3 1x or Windows 95 but if you have trouble see section 10 of the Windows readme file 5 9 Using the programmer software over a network It is possible to run the programmer software from a network hard drive with the programmer itself connected to the local computer Some networks do not pass the full execution path to the EXE file The CWGANG program therefore has difficulty in locating the library and device files To circumvent this problem use the following environment variables to set the full network path of the executable For ChipWriter Gang SET CWGANG PATHNAME where PATHNAME is the full network path where CWGANG EXE is located For example if the programmer software is held in Z CWGANG Then the statement set CWGANG Z CWGANG should be added to the AUTOEXEC BAT file of the computer where the programmer is connected 5 10 Using EMS software The programmer is supplied with EMS software which will enable expanded memory to be accessed if it is available This requires an expanded memory ma
6. WINDOW Usage Window trow lcol brow rcol type fgcol bgcol title trow 1col is the position of the top left corner of window on screen 0 0 to max of 22 77 brow rcol is the position of the bottom right corner of window on screen trow 2 Icol 2 to max of 24 79 type is the type of border O double 1 single 2 blank 3 horizontal double fgcol foreground colour bgcol background colour title is the optional title for the window If title is specified then fgcol and bgcol must also be specified WAITKEY Usage keylist For example Waitkey keylist is a list of chars to wait for All others are ignored Possible keys are A Z 0 9 F1 F10 UP DOWN LEFT RIGHT SPACE ENTER PAGEDOWN PAGEUP HOME END ESC or DEFAULT Returns when a key in keylist is pressed and sets the ERRORLEVEL equal to the position of the key within the keylist leftmost argument 1 etc If DEFAULT is specified any key not in the keylist returns ERRORLEVEL 0 waitkey CR space F10 a b c DEFAULT F ERRORLEVEL 6 goto Keyc F ERRORLEVEL 5 goto Keyb F ERRORLEVEL 4 goto Keya F ERRORLEVEL 3 goto FIOKEY F ERRORLEVEL 2 goto SPACE F ERRORLEVEL 1 goto CR default Note Since in DOS ERRORLEVEL n statement implies ERRORLEVEL gt n then a reverse order is important here WARN Usage Warn message fgcol bgcol bfgcol bbgcol type fgcol for
7. 1 4 Low Voltage features The ChipWriter programmer supports Low Voltage 3 3V devices as well as standard 5V devices It is capable of programming and verifying devices down to 3 3 Volts When using low voltage devices the programming algorithm in the system will automatically be set to the correct voltages as specified by the manufacturer s programming algorithm Even if the manufacturer s algorithm specifies verification at 5 volts you may wish to verify a device at 3 3V to ensure that it will work in your low voltage system with the capabilities of the ChipWriter Gang programmer it is possible to do this See section 6 6 for full details 2 Installing the Software 2 1 Latest software Both device programming algorithms and system operating firmware for this new line of programmers is distributed via the BBS WEBpage Since software algorithms are added on a regular basis it is possible that the software provided with your new system has been superseded by a newer revision To insure that you have all the latest device programming algorithms an system software installed on your programmer it is recommended that you contact the Data IO BBS WEBpage Contact information is given in Appendix C of this manual 2 2 Running the Install program An install program is provided on CD ROM This software copies all of the necessary files onto your hard drive We suggest that you use the following directories to hold the programmer software C
8. DATAIO CWGANG Where C is the name of your hard drive So if you are installing the software onto the C drive to run the installation program place the CD ROM in the drive and log onto this drive by typing E or F as necessary Now type INSTALL C DATAIO CWGANG lt ENTER gt After installation you should add this directory to your current PATH statement in your AUTOEXEC BAT file For example change PATH C DOS C BAT C UTILS to PATH C DOS C BAT C UTILS C DATAIO CWGANG Then reset the PC 3 Connecting the Programmer 3 1 Computer requirements The programmer will operate with any IBM compatible PC 386 and above recommended with a standard IBM CENTRONICS interface parallel printer port This means that it is very easy to move between PCs Users who prefer to have an internal card or who do not wish to use their existing parallel port can fit an additional parallel card available from any PC supplier Alternatively a manual switch box may be used Please note that the programmer is designed to use the Standard Printer Port configuration SPP Users with port settings in their BIOS or on Enhanced parallel port cards should NOT select the EPP or ECP options The software is compatible with MS DOS v 3 0 or later and with MS Windows v 3 1 or Windows 95 3 2 Connection to the PC STEP 1 Connect one end of the parallel cable to the programmer The other end of
9. T Devicename Alt N DOS Command Alt D Display Mode Alt Y Gang Mode Alt 1 Sets of 2 Alt 2 Sets of 4 Alt 4 Appendix B Menu Options This section gives a brief overview of each of the menu options available in CWGANG EXE and tells you in which section of the manual you will find more detailed information CWGANG EXE Menu Option Section FILE MENU Open 6 2 Open a binary or HEX formatted from disk and load it into buffer memory area Save As 6 2 7 Save an area of the buffer to a binary or formatted file on disk Save 6 2 7 Save the currently loaded file Exit 5 11 Exit the software and save the settings DATA MENU Edit 6 3 1 Edit the contents of the data buffer View 6 3 2 View the contents of the data buffer without making any changes Fill 6 3 4 Fill an area of the buffer with a specified value Copy 6 3 4 Copy an area of the buffer to another area Search 6 3 3 Search an area of the buffer for a specified value or string Goto 6 3 3 Goto a user specified area of the buffer Swap Bytes 6 3 4 Swaps odd and even bytes Useful for data into more than 1 EPROM Buffer Size 6 2 1 Changes to size of the buffer Print Prints out an area of the buffer Checksum Calculates a checksum over a given area PROCESS MENU Read Read the device in the ZIF socket and store the data in the buffer Verify Verify the data in the device against the data in the buffer Verify Electronic ID Checks t
10. current device address on next line of screen default displays current device address at screen row R col C requires ANSI SYS buffer size in Kbytes Min 64 default device size to system max number of times to repeat Each repeat is prompted at R C The R C parameters of the e command must be specified ignore electronic signature error and continue to program gives this help screen GPREAD file options file is filename for output device start address in HEX default MIN ADDRESS device end address in HEX default MAX ADDRESS error quiet mode i e error returned only via ERRORLEVEL displays error message on next line of screen default displays error message at screen row R col C requires ANSI SYS displays current device address on next line of screen default displays current device address at screen row R col C requires ANSI SYS gives this help screen GPVERIFY file options file is filename to verify against device start address in HEX default MIN ADDRESS device end address in HEX default MAX ADDRESS file window low address default 0 file type is BinaryIHEX default HEX file increment 1 every byte word 2 every other byte word etc error quiet mode i e error returned only via ERRORLEVEL displays error message on next line of screen default displays error message at screen row R col C requires ANSI SYS buffer size in Kbytes Min 64 default device size to system max numbe
11. options ORGANISATION Select from given options LAYOUT Select from given options PULSE TYPE Select from given options PULSE WIDTH pS Typical values are 100 for the latest EPROM s 1000 for older 2764 to 27010s 50000 for 2716 and 2732 MAX NUM OF TRIES Typical values are 1 25 OVER PROGRAM Enter over program pulse width OverProg Pulse select variable or fixed Generally N A or variable 4 Once device parameters have been modified for the user database select DEVICE ADD TO USER DATABASE to add them to the database on disk 7 Stand Alone Mode The ChipWriter Gang can be configured to be used away from a PC This allows the programming specifications to be completely controlled away from the production area thus reducing the margin for operator error The Stand Alone mode can work in one of two ways The programmer contains a serial EEPROM which can be set up with the specifications for the device to be programmed The data to be copied can then be programmed into a master device Exact copies can then be made from the Master socket into any of the Copy sockets 0 to 7 This would be the normal method for copying EPROM s or EPROM s The device settings remain stored when the power is turned off The second method is to download the device parameters into any 27C512 EPROM The programmer uses this to store the programming configuration data and algorithms This method would typically be
12. the device which is being used 6 1 1 To select a device To do this enter CWGANG EXE and select DEVICE MANUFACTURER A list of supported manufacturers will be displayed on the screen Use the up and down cursor keys to find the manufacturer of the device you are using You can also press the initial letter of the manufacturer you need e g pressing lt M gt will take the cursor down to MACRONIX When the cursor is highlighting the required manufacturer press lt ENTER gt You will then be given a choice of device types to select Highlight the type required or press the first letter and press lt ENTER gt The software then displays a list of all the supported devices of the manufacturer and type selected Highlight the required device name and press lt ENTER gt again The details of the selected device will then be displayed in the bottom device of the screen 6 1 2 Changing the device selected Once a device has been selected to select another device of the same manufacturer and type press DEVICE DEVICE NAME To select another device type within the same manufacturer select DEVICE TYPE 6 1 3 Which device Generally it is necessary to select the device name which is as close as possible to that stamped on the chip you are using The software uses the correct nomenclature according to the manufact
13. the power up code These are typically in HEX 01 2716 02 2732 03 2764 04 27128 05 27256 06 27512 07 27010 08 27020 09 27040 0A 27080 etc 11 2816 ete If any other power up codes or error codes are reported contact Data I O or your distributor 8 Batch Software Software for batch processing on the ChipWriter Gang is provided free of charge Contact Data I O or download from the BBS or Web site 8 1 Batch software commands GPCONFIG usage GPCONFIG m manf typ n devicename options This command needs to be run first in order to configure the programmer for Batch mode operation where options eq e e R C p 1 213 h GPBCHK usage options ds ADDR de ADDR eq GPCHKSUM usage options ds ADDR de ADDR eq man f is the manufacturer file name and typ eprleeplucs see EPROMPAR directory for a complete list devicename is an exact devicename as shown in menu software error quiet mode i e error returned only via ERRORLEVEL displays error message on next line of screen default displays error message at screen row R col C requires ANSI SYS parallel port default 1 gives this help screen GPBCHK options device start address in HEX default MIN ADDRESS device end address in HEX default MAX ADDRESS error quiet mode i e error returned only via ERRORLEVEL displays error message on next line of screen default disp
14. 1 0561 Canada For technical assistance contact Data I O Customer Resource Center Telephone 800 247 5700 Fax 425 869 2821 For repair or warranty service contact 6725 Airport Road Suite 302 Mississauga Ontario L4 V 1V2 Telephone 905 678 0761 Fax 905 678 7306 Japan For technical assistance repair warranty service contact Data I O Japan Osaki CN Building 2F 5 10 10 Osaki Shinagawa Ku Tokyo 141 Telephone 3 3779 2207 Operations 3779 2203 Other Germany For technical assistance repair warranty service contact Data I O GmbH Lochhamer Schlag 5a 82166 Grifeling Telephone 089 858580 Fax 089 8585810 Other European Countries For technical assistance repair or warranty service contact your local Data I O representative Other Countries World wide For technical assistance repair or warranty service contact the office below and ask for the number of your local Data I O representative Data I O International 10525 Willows Road N E P O Box 97046 Redmond WA USA 98073 9746 Telephone 425 881 6444 Fax 425 882 1043 Telex 4740166 Technical Assistance You may contact Data I O for technical assistance by calling sending a fax or electronic mail e mail or using the Bulletin Board Service BBS To help us give you quick and accurate assistance please provide the following information Product version number Product serial number if available Detailed description o
15. 5 Adapter usage Getting Started 4 1 Before you start 4 2 Quickstart Tutorials TUTORIAL 1 Programming from a master device TUTORIAL 2 Programming from a file on disk TUTORIAL 3 Programming in Stand Alone Mode Using the Programmer Software 5 1 Basic software configuration 5 2 Screen layout 5 3 General menu selection 5 4 Dialogue boxes 5 5 Changing the settings 5 6 Using a mouse 5 6 1 Left mouse button 5 6 2 Right mouse button 5 6 3 Middle mouse button 5 6 4 Disabling the mouse 5 7 Edit and View modes and scroll bars 5 8 Running the software under Windows 5 9 Using the programmer over a network 5 10 Using EMS software 5 11 Saving software settings Memory Programming 6 1 Device Selection 6 1 1 To select a device 6 1 2 Changing the device selected 6 1 3 Which device 6 1 4 Low Voltage devices 6 2 Opening files 6 2 1 Setting the buffer size 6 2 2 Opening a file N DANU VO O o0 o0 OW 16 16 17 17 16 18 6 2 3 File format 6 2 4 Handling large files and devices 6 2 5 File checksum 6 2 6 Wild card loading 6 2 7 Saving a file to disk 6 3 Using the editing facilities 6 3 1 Entering Edit mode 6 3 2 Viewing without making changes 6 3 3 Quickly moving around the buffer 6 3 4 Quick buffer editing commands 6 3 5 Buffer checksum 6 3 6 Buffer display modes 6 3 7 Printing the buffer contents 6 4 Reading and checking devices 6 4 1 Reading a device 6 4 2 Verifying the contents of a device against a file 6 4 3 Ve
16. PROM place the device in the Master socket If you are using the Internal EEPROM ensure that the Master socket is empty When the programmer is powered up it waits to see if there is a message from the PC If no message is received it looks for a 27C512 EPROM in the Master socket If no device is present it looks in the internal EEPROM If no data is found or if there is a problem locating the Configuration EPROM the Master LED will flash three times in succession and will continue this error message until the machine is reset Once the machine has found the correct device parameters LED S 0 7 will display a code byte indicating which type of device it has been configured for See section 7 6 for more information Once the code has been checked clear the display by pressing RESET 7 3 1 Programming in stand alone mode Place the DATA Master EPROM in the master socket then place the blank devices in sockets 0 7 Press START to begin programming While programming is taking place the indicator LED s will light for each socket in which there is a device the Master LED will flash During the VERIFY stage the Master LED will remain on permanently If programming is successful a walking sequence will appear on the LED s LED s 0 4 1 5 2 6 3 7 If unsuccessful the LED s will flash to indicate which sockets have failed NOTE Flash memory devices cannot be programmed in stand alone mode Flash devices require a sequenc
17. The information needed to add your own devices will be found in the relevant data sheet Please contact the device manufacturer for up to date information Please Note e User defined programming information may not work for Flash PROM s since not all of these have standard programming algorithms e In order to protect the manufacturer recommended algorithms it is not possible for the user to change the manufacturers database The procedure for adding user defined devices is as follows 1 Select a device which is similar to that to be added from the devices menu This will minimise the number of changes which it is necessary to make and will ensure that the relevant options are displayed Have ready the device data sheet 2 Select DEVICE MODIFY PARAMETERS This will access the User database thus protecting the manufacturer database from unintentional changes 3 Modify the required parameters Note Always modify parameters in a top to bottom order DEVICE NAME can be up to 16 characters DEVICE CODE Electronic signature on chip ANUFACTURER CODE Electronic signature on chip Uf the ID codes are left blank then the Electronic Signature check will be disabled VecP Vcc during programming Enter the desired voltage Vpp Programming voltage Enter the desired voltage Vcc During Verify Select from given
18. USER MANUAL For the ChipWriter GANG Gang Set Memory Device Programmer DATA 1 0 March 2001 ChipWriter Gang Manual ver 1 0 Data I O has made every attempt to ensure that the information in this document is accurate and complete Data T O assumes no liability for errors or for any incidental consequential indirect or special damages including without limitation loss of use loss or alteration of data delays or lost profits or savings arising from the use of this document or the product which it accompanies No device of this document may be reproduced or transmitted in any form or by means electronic or mechanical for any purpose without written permission from Data I O Data I O Corporation 10525 Willows Road N E P O Box 97046 Redmond Washington 98073 9746 USA Acknowledgements Data I O and ChipWriter are registered trademarks of Data I O Corporation Data I O Corporation acknowledges the trademarks of other organizations for their respective products or services mentioned in this document 1997 Data I O Corporation All rights reserved Contents 1 Introduction 1 1 About this manual 1 2 Conventions 1 3 Contents of the package 1 4 Low Voltage Features Installing the Software 2 1 Latest software 2 2 Making a backup 2 3 Running the Install program Connecting the programmer 3 1 Computer requirements 3 2 Connection to the PC 3 3 Running the Detect program 3 4 Programming non DIP devices 3
19. Using the Programmer Software 5 1 Basic Software Configuration The operating software contains the following program CWGANG EXE Used to program EPROM s EPROM s and Flash PROMS These are menu driven programs which contain all the features required to program and test devices The actual programming information for individual devices is held in library files which allows easy updating of the software to accommodate new devices and algorithm updates Command line Batch software is also included which allows the programmer to be operated from DOS batch files Details of the commands available are shown in section 8 On first installing the software and programmer on a PC remember to alter the parallel port selection within CWGANG EXE by selecting OPTIONS PARALLEL PORT NO 5 2 Screen layout Each program displays information as follows Menu headings are displayed across the top of the screen Device programming details are displayed in the bottom window Data memory contents are displayed in the main window The software and library version numbers are displayed at the top of the screen just below the Menu bar These are useful to note should you need to contact Technical Support or to check for new version numbers on the BBS or Internet 5 3 General menu selection The software has been designed to make the programmer as simple as possible to use All functions are contained within the menu system The me
20. butor or local sales office 2001 Data I O Corporation
21. cted to a PC for the first time Once the parallel port has been chosen it will be remembered when next using the programmer OPTIONS COLOR MODE To choose whether the display is MONO or COLOR OPTIONS SNOW PRECAUTIONS Usually set to OFF but set it to ON if you have problems with snow on your monitor affects older PC s with CGA OPTIONS HI RES MODE Select ON for 40 50 line mode Effective only with EGA and VGA monitors 5 6 Using a mouse The software can be mouse driven However your mouse driver software must previously have been installed This is normally done automatically in your CONFIG SYS file by loading a device driver such as MOUSE SYS or in your AUTOEXEC BAT file by invoking a mouse driver program such as MOUSE COM If you are unsure how to do this please refer to your system manual or the manual supplied with your mouse CWGANG EXE automatically enables the mouse if one is installed see later if you wish to disable it 5 6 1 Left mouse button LMB The LMB is used to select items in a list such as a menu selection or a device name from the device list Simply move the pointer to the required item and press the LMB If the item is a menu heading such as FILE PROCESS etc then this will open up that particular menu If the item is a sub menu or part of a list this will highlight the chosen item To select the highlighted item Double Click on the LMB Double Cl
22. d byte and every fourth byte from there sockets 4 and 5 will contain the third byte and every fourth byte from there Sockets 6 and 7 will contain the MSB or the fourth address and then every fourth byte in the buffer 6 5 5 Erasing devices For Flash memory and some parallel EEPROM parts which support a device erase feature use PROCESS ERASE This electrically erases the data held on the chip To erase all other EPROM s as well as NVRAM s fill the buffer with FF Hx and program the whole device 6 6 Adding user defined devices If you need to program a device that is not on the list please contact Data I O or your distributor to find out if it is available on the latest software For EPROM EEPROM devices that have not yet been implemented there is the facility to add user defined devices The user database can also be used to keep frequently used devices from different manufacturers in one place rather than having to select these devices via the menu system every time To do this select the device required then select DEVICE ADD TO USER DATABASE The device name could be changed to a project name if required using DEVICE MODIFY PARAMETERS before adding to the user database Note This feature is for the convenience of advanced users only Data I O Corp cannot be held responsible for incorrect programming using the user database
23. e foolproof and need to be used with some caution To verify the signature of a device select PROCESS VERIFY ELECTRONIC ID If the database contains a manufacturer s code and device code they can be verified against that of the device 6 4 4 Checking if a device is blank In order to program a device it must either be fully blank or be capable of containing the information to be programmed into it in addition to the information it already contains In order to test whether a device is completely unprogrammed select PROCESS BLANK CHECK This option checks if the device is blank all 1 s or all 0 s depending on the actual part NOTE It is possible for a device to appear blank even though it is not fully erased If problems are encountered in programming a device try erasing it for a longer period and then reprogramming 6 5 Programming and erasing devices IMPORTANT NOTE Data I O use only the specified programming algorithms as provided by the semiconductor vendors While every effort is made to ensure that programming algorithms are correct the said algorithms are not guaranteed by the manufacturers and therefore cannot be guaranteed by Data I O Users are advised to ensure that devices work correctly in their systems before programming large quantities 6 5 1 Programming devices To program the selected device use PROCESS PROGRAM This performs a blank check chip erase f
24. e of bytes to be written to them in order to initialise the Read operation As the Master socket is READ only in order to eliminate any possibility of the Data Master device being corrupted it is not possible to write any initialisation codes to the Master socket 7 3 2 Verifying in stand alone mode Devices are automatically verified after programming If it is wished to verify them separately press and hold RESET then press START while still keeping RESET held down then release START then release RESET For any device which fails to verify the associated LED will flash Press RESET to clear the error 7 4 LED Codes The eight Copy socket LED s and the Master socket LED represent a different programmer status at different times 7 4 1 LED status Flashing Master LED repeated three times Bad Master device or internal EEPROM not set up correctly Flashing Master LED and any other flashing LED Misaligned or faulty device If all eight socket LED s flash this implies that all sockets are faulty or empty Flashing Master LED and any other non flashing LED Programming is taking place Master LED on and other LED s off Verifying Master EPROM Master LED off and any other flashing LED Verify error Master LED off and any other non flashing LED Power up code for device 7 4 2 Power up codes When the ChipWriter Gang is configured for stand alone mode it will inform the user of
25. e placed in the socket in the live bug position i e with legs downwards for all sockets 28 pins and above 20 pin sockets are dead bug loading Push the device down to lock in place then push down the socket sides to release See figure 3 1 below AD32PL32 Master Socket Copy Socket Figure 3 1 Adapter Usage 4 Getting Started We have provided some quickstart tutorials to help you start using the programmer as quickly as possible If you have not used a programmer before these may help you to begin However these should not be taken as a comprehensive guide to the programmer s capabilities The following tutorials are provided TUTORIAL 1 Programming from a master device TUTORIAL 2 Programming from a file on disk TUTORIAL 3 Programming in Stand Alone mode These tutorials are provided to get you using the programmer quickly for simple tasks However we recommend that you read the reference sections of the manual if you have any difficulty and before attempting any more complex operations The quickstart tutorials use the menu driven software For information on how to use the batch DOS command software see section 8 4 1 Before you start If you are not sure how to select menu items please see section 5 3 for more information Figure 4 1 below illustrates the orientation of devices in the programmer The chip inserted in the MASTER socket is located at the bottom of the ZIF socket with the bo
26. e screen Ensure that the data memory buffer size is large enough to hold the data to be read from the master device You can change the buffer size using DATA BUFFER SIZE See section 6 2 1 for more information E OPEN Select PROCE programmed ESS PROGRAM Press lt F 10 gt to accept the default addresses 0 Appropriate messages will be displayed at the end of programming showing which devices have been correctly which sockets are empty etc TUTORIAL 3 Programming in Stand Alone Mode The programmer can be configured to work in stand alone mode in two ways Using the internal EEPROM OR Using Configuration EPROM s Both methods require a DATA Master EPROM programmed with the required copy data See the above tutorials Setting up the Internal EEPROM 1 Type CWGANG lt ENTER gt 2 Select the device you are wanting to program using DEVICE MANUFACTURER Select the manufacturer and press lt ENTER gt You will then be given a list of different types of devices Select the type and press lt ENTER gt You will then be prompted for the device name Choose the correct device name from the menu you are given and press lt ENTER gt to accept The details of the device you have chosen will now be displayed at the bottom of the screen 3 From the MODE menu select the option SET UP INTERNAL EEPROM The programmer is now configured for the selected device A power on code is disp
27. eground colour bgcol background colour bfgcol bbgcol refers to border surround type is the type of border O double 1 single 2 blank 3 horizontal double default is white on black type 1 border 8 3 Batch software error levels Message Returned Error Level No Error 0 Bad Command Line Parameters 1 No Environment Variable found 2 Manufacturers File Not Found or Invalid 3 Bad Devicename Specified 4 Bad Device Driver Specified 5 Programmer is not a ChipWriter Gang 6 Bad Library File 8 Bad communication with Programmer 9 Checksum Error 10 Memory Error 11 Bad file Read 12 Bad Device Specified 13 File was not found or could not be opened 14 Bad definitions in Command Line Parameters 15 Bad address range has been specified 16 Device is not Blank 17 Verify Error 18 Device or Parameter is not Programmable 20 Bad Electronic Signature 21 Device is not Secure 22 Device not Erased 24 See Error Log File 128 Any other values are internal errors and you should contact Data I O before continuing 8 4 Batch software examples Example 1 This batch file shows the simplest way of using the batch programs No error checking is done and all information is echoed to the screen EM Setting up the environment variable to point to the ChipWriter software EM This only needs to be done once and may be done in the AUTOEXEC BAT file ET CWGANG C DATAIO CWGANG R R S REM Configuring the programmer to program Signetics 27C64A G R
28. ese features and how to use them 1 1 About this manual This manual provides the instructions for using the ChipWriter Gang programmer from Data I O It is organised so that is possible to program a device quickly by following one of the QuickStart tutorials A reference section follows which gives instructions in greater detail It is recommended that you read through the relevant sections of this manual before using the programmer and in case of any difficulties you encounter during use 1 2 Conventions Throughout this manual certain conventions will be followed in typefaces in order to make instructions clear e g In the line Type CWGANG lt ENTER gt CWGANG this font is used throughout the manual to indicate something that should be typed into the computer lt ENTER gt Any items encased in lt gt indicate the name of a key to press i e in this case the ENTER key Menu selections are indicated by words separated by forward slashes e g FILE OPEN indicates the menu option FILE followed by the sub menu option OPEN Messages displayed by the programmer software are indicated in italics for example DEVICE PROGRAMMED AND VERIFIED 1 3 Contents of the package When you open the package you will find e ChipWriter Gang Set memory device programmer e ACD ROM disk containing the software for the programmer e User manual e A power supply A D25 male male parallel cable
29. f the problem you are experiencing Error messages if any Device manufacturer and part number if device related Calling Calling the appropriate Data I O Customer Support number listed at the front of this Appendix When you call please be at your programmer or computer have the product manual nearby and be ready to provide the information listed above Sending a fax Fax the information listed above with your name phone number and address to the appropriate Data I O Customer Support fax number listed at the front of this Appendix Sending E mail To reach Data I O via e mail send a message including your name phone number e mail address and the information listed above to the following address techhelp data io com Logging on to the BBS The Data I O Bulletin Board System BBS enables you to e Obtain a wide range of information on Data I O products including current product descriptions new revision information technical support information application notes and other miscellaneous information Access device support information Request support for a particular device Leave messages for the BBS system operator Customer Support personnel or other customers Download many DOS and Windows utilities Online help files provide more information about the BBS and its capabilities Before you can log on to the BBS you must have your telecommunications software and modem installed and operating Refer to your telec
30. firmware version To find out which firmware version you are using run DETECT The firmware 5 6 version number is displayed at the end of the test The software version and library version for the device you are programming To find out which version of the library you are using connect the programmer and run CWGANG Select the manufacturer and device name of the device being programmed The library version number is then displayed on the third line of the screen The results of the DETECT program To run the program ensure that you are in the directory containing the programmer software e g C CWGANG and type DETECT at the DOS prompt The program will then report on which port the programmer is connected to This information can then be used to set up the parallel port in the CWGANG EXE software If an error is reported then obtain a printout by using DETECT gt PRN or DETECT gt ERROR LST followed by PRINT ERROR LST The exact device name of the device you are programming An exact note of any error messages you are getting It will assist our engineers if you are next to the programmer when calling Data I O Customer Support United States For technical assistance contact Data I O Customer Resource Center Telephone 800 247 5700 Fax 425 869 2821 For repair or warranty service contact Data I O Central Dispatch Telephone 800 735 6060 Fax 425 88
31. he electronic signature of the device Blank Check Checks to see if a device is blank Program Programs data in the buffer into the device inc Verify Sig amp Verify Erase Erases Electronically erasable devices DEVICE MENU Manufacturer Selects the manufacturer of the device to be programmed Type Selects the type of device to be programmed DeviceName Selects the devicename of the device to be programmed Modify Parameters Allows users to add their own devices Add to User Database Stores new devices in the user library OPTIONS MENU Parallel Port 6 4 1 6 4 2 6 4 3 6 4 4 6 1 6 1 6 6 6 6 5 5 Tells the software which parallel port the programmer is connected Screen Colour Selects either mono or colour displays Snow Precautions Overcomes snow problems on old CGA displays Hi Res Mode Changes number of lines on EGA and VGA displays Display Mode Switch between 8 12 16 bit display DOS Command Enables a DOS command to be run from the software 5 5 5 5 5 5 5 5 5 3 APPENDIX C Technical Assistance Warranty and Repair This appendix includes details about contacting Data I O for technical assistance repair and warranty services The appendix also explains the Bulletin Board Service If you require technical support for any reason please ensure that you have the following information on hand 1 The serial number of your programmer 2 The
32. he programmer is connected to This information can then be used to set up the parallel port in the main CWGANG menu software If any error is reported then you will need to contact Data I O Technical Support or your distributor In order to assist with your problem it is possible to obtain a printout of the Detect results by using DETECT gt PRN where PRN is the name of the resident printer device i e LPT 1 or DETECT gt ERROR LST followed by PRINT ERROR LST See Appendix C for Technical Support information 3 4 Programming non DIP devices Devices in packaging other than DIP require socket adapters A range of adapters is available from Data I O for most common devices If you are unsure as to which adapter to use please contact Data I O or your distributor for advice Adapters from other sources which are simple pin conversions can usually be used successfully Where devices require non standard adapters to be supported these are available from Data I O All adapters available from Data I O are standard across the ChipWriter range 3 5 Adapter usage Insert the adapter into the ZIF socket of the programmer with the bottom end of the adapter in the bottom pins of the socket The text on the adapter boards should be the right way up Lock the ZIF socket handle in place For PLCC adapters the notched corner of the adapter socket will usually be in the top left hand corner Devices ar
33. icking performs the same action as pressing lt ENTER gt 5 6 2 Right mouse button RMB Pressing the RMB is exactly the same as pressing lt ESC gt 5 6 3 Middle mouse button MMB Pressing the MMB is exactly the same as pressing lt F 10 gt When this key is a possible input the window being displayed will have F10 in the bottom border Pointing at the text F10 and pressing the LMB will also produce the same result for two button mouse users 5 6 4 Disabling the mouse To disable the use of the mouse invoke each of the programs with the NM option e g CWGANG NM 5 7 Edit and view modes and scroll Bars In order to observe data in the data buffer area without risking modification a VIEW mode is available in the DATA menu This will only allow scrolling paging etc Mouse users can enter this mode directly by pointing at the buffer window and pressing the LMB In order to make moving around the buffer much easier Scroll Bars have been added to the window borders 5 8 Running the software under Windows The CWGANG software can be run in a DOS window under Windows 3 1x or Windows 95 Example PIF and ICO files are included To create an ICON for the ChipWriter CWGANG EXE for example on Windows 3 1 do the following Select NEW PROGRAM ITEM in the Program Manager FILES NEW menu Change Description to CWGANG Change Command Line to
34. l move to the HEX display in the buffer window Use the lt TAB gt key to switch between HEX and ASCII 6 3 3 Quickly moving around the data The lt HOME gt and lt END gt keys allow you to move more quickly Press once to move to the beginning end of the line twice to move to the beginning end of the page or three times to move to the beginning end of the file When you have finished editing or viewing the buffer press lt ESC gt to return to the main menu 6 3 4 Quick buffer editing commands DATA FILL Allows you to fill a defined area of the data area with information in byte word or long word format Enter the buffer start and end addresses and the information to be inserted Use less than 3 characters for a byte 3 or 4 for a word more than 4 for a long word Press lt F 10 gt to accept DATA COPY Copies a defined block of buffer memory to a new location DATA SEARCH Searches for data in HEX OCTAL or ASCII format Use the Up Down arrow in the dialogue box to move between HEX OCTAL and ASCII data entry DATA JUMP TO Jumps to a chosen address in the data area DATA SWAP BYTES Swaps odd and even bytes within a defined range 6 3 5 Buffer checksum The command DATA CHECKSUM performs a checksum on the contents of a user defined range in the buffer Select BUFFER START ADDRESS default to 0 BUFFER END ADDRESS default to end of buffer
35. layed see section 7 6 for full information Setting up a Configuration EPROM The configuration EPROM needs to be a standard 27C512 device 1 Type CWGANG lt ENTER gt 2 Select the device you will be programming in Stand Alone Mode using DEVICE MANUFACTURER Select the manufacturer and press lt ENTER gt You will then be given a list of different types of devices Select the type and press lt ENTER gt You will then be prompted for the device name Choose the correct device name from the menu you are given and press lt ENTER gt to accept The details of the device you have chosen will now be displayed at the bottom of the screen Use DATA F ILL to ensure the buffer is filled with FF From the MODE menu select the option SET UP MASTER EPROM The on screen memory area now contains the required programming information for the selected device type Using the same method as in 2 select the 27C512 device you will be using as the CONFIGURATION master Place the device into one of the 8 copy sockets of the programmer Select PROCESS PROGRAM Press lt F 10 gt to accept the default addresses Appropriate messages will be displayed at the end of programming showing that the device has been programmed correctly and which sockets are empty etc AW w
36. lays error message at screen row R col C requires ANSI SYS gives this help screen GPCHKSUM options device start address in HEX default MIN ADDRESS device end address in HEX default MAX ADDRESS error quiet mode i e error returned only via ERRORLEVEL displays error message on next line of screen default displays error message at screen row R col C requires ANSI SYS displays current device address on next line of screen default displays current device address at screen row R col C requires ANSI SYS gives this help screen GPPROG usage where options ds de fl ft ADDR ADD ADDR ve c fi eq GPR B H 1 214 R C NUM NUM EAD usage where Options ds ADDR de ADDR GPVE eq RIFY usage where options ds de fl ft ADDR ADD ADDR B H ve c TL eq 1 214 Ry NUM NUM GPPROG file options file is filename containing data to be programmed device start address in HEX default MIN ADDRESS device end address in HEX default MAX ADDRESS file window low address default 0 file type is BinaryIHEX default HEX file increment 1 every byte word 2 every other byte word etc error quiet mode i e error returned only via ERRORLEVEL displays error message on next line of screen default displays error message at screen row R col C requires ANSI SYS displays
37. nager compatible with EMS 3 2 standard It allows up to 8 Mb of memory and will run on any PC with an expanded memory board or a 286 or 386 with an expanded memory manager The software will not give the EMS option if a driver such as EMM386 EXE is not installed correctly If the EMS function is working correctly it will be possible to increase the data memory buffer size to 1024K without problem If this is not possible and the maximum it can be set to is 384K for instance then the EMM3386 driver has not been correctly installed Check the CONFIG SYS file in the root directory on your hard drive to check that the following line exists DEVICE C DOS EMM386 EXE Also ensure that the NOEMS option has not been included on this line DOS maybe replaced by WINDOWS if you are running under Windows 95 It is also possible to run MEMMAKER and select YES when prompted for EMS memory requirements 5 11 Saving software settings When exiting the programmer software settings such as parallel port the device chosen etc are automatically saved to avoid having to repeatedly set up the chosen options 6 Memory Programming This section covers the all the memory type devices which are programmed using CWGANG EXE To use this program at the DOS prompt type CWGANG lt CR gt 6 1 Device selection In order to tell the programmer software which programming algorithm to use it is necessary first to select
38. ne point to note is that these parameters are stored each time the software is quit If in a previous session FWLA was changed to 10000 HEX then files with information in the range 0 FFFF will appear empty Therefore it is important to check all the load parameters each time a file is opened 6 2 5 File checksum When a file has been opened and loaded into the data buffer a checksum is calculated on the contents of the file and displayed on the screen This is displayed as three figures a The sum of unsigned bytes with the carry being added to the MSB of the checksum b The complement of a c The arithmetic negative of a NOTE The checksum displayed on FILE OPEN is the checksum of the FILE only and does not necessarily include the whole address range of the selected device A checksum of the device or of a particular address range can be calculated using DATA CHECKSUM as explained in 6 3 5 6 2 6 Wild card loading Wild cards may be used in the filename to perform drive directory searches Wild cards consist of and matches to any number of characters matches to any one character A list of matching filenames is displayed alphabetically Sub Directories first and the user may select using the cursor keys or the first letter of the name 6 2 7 Saving a file to disk Data edited in the buffer area or read in from a device can be saved to disk in a number of different formats It is recommended
39. nus are obtained by pressing the lt ESCAPE gt key The user can then move around the menus by pressing the cursor keys To select an option press lt ENTER gt Each menu function is available by pressing the first letter of the function For instance the DEVICE pull down menu is available by pressing the D key Some options can be selected by pressing ALT letter These are indicated by a triangle next to a letter on the menu display For example Program can be selected by pressing ALT P A full list of shorthand keystrokes is given in Appendix 1 5 4 Dialogue boxes The menu system makes extensive use of dialogue boxes Within these boxes the following prompt types may appear Prompt requires you to type in some information gt will display a series of options when you press lt ENTER gt Inside the dialogue boxes use the cursor keys to move between options use lt ENTER gt to select the contents of the dialogue box Use lt F10 gt to accept all chosen options within the window If you wish to abort from the window press lt ESCAPE gt 5 5 Changing the settings Before starting you may wish to change any of the following They are found in the OPTIONS menu This will have to be done for both EPROM and PAL OPTIONS PARALLEL PORT NO Selects parallel port to be used This is detected by the DETECT utility which should be run when the unit has been conne
40. ny of the address settings before proceeding again by pressing LEES 6 5 3 Gang programming The ChipWriter Gang is designed to program up to 8 devices at a time From the menu bar select MODE GANG MODE This allows the user to program 1 to 8 devices placed in sockets 0 to 7 with the same information It is not necessary to specify how many sockets are being used or which sockets they are All of the functions in the PROCESS menu other than READ can be performed simultaneously on multiple devices once the gang mode has been selected The PC displays the status of each socket during each function 6 5 4 Set programming The ChipWriter Gang can program in 16 bit or 32 bit Set modes For 16 bit mode select MODE SETS OF 2 The programmer will send information into 4 sets of 2 devices Sockets 0 to 3 will contain the LSB or the first address specified from the buffer and then every second byte in the buffer This maybe ODD or EVEN addresses depending on the given Start address Sockets 4 to 7 will contain the MSB or the second specified address and then every second byte in the buffer For 32 bit mode select MODE SETS OF 4 The programmer will send information into 2 sets of 4 devices Sockets 0 and 1 will contain the LSB or the first byte specified from the buffer and then every fourth byte This maybe ODD or EVEN addresses depending on the given Start address Sockets 2 and 3 will contain the secon
41. ommunications software manual and your modem manual for setup procedures Have the following information available prior to contacting the BBS Name and Password File transfer protocol used by your telecommunication software Use the following procedure to log on to the BBS e To contact the BBS call one of the following numbers Modem United States 1 206 881 3465 Germany 49 89 858 5880 49 89 858 5833 Japan 8 1 3 3779 2233 Internet Using telnet go to bbs data io com e If this is the first time you have called when the logon screen appears type new at the prompt to create a new account and provide the requested information Note Be sure to write down your user name and password for future reference This is your personal BBS account and should not be shared e Select the Library Files menu e Select the ChipWriter Library CHIPWRIT e Search for the ChipWriter Gang files Using the Data I O Web Page The Data I O Home Page on the World Wide Web WWW includes links to online information about technical products general information about Data I O a list of sales offices and technical user information such as application notes and device lists To access the WWW you will need an Internet account with Web access and a Web browser such as Netscape or Mosaic The address of the data I O Home Page is http www data io com You may also access the data files from an FIP at the following address location ft
42. or electrically erasable devices program and verify After selecting the PROGRAM option a dialogue box is displayed which enables the required Programming Parameters to be selected The most basic configuration will offer the following options DEVICE START ADDRESS Enter the address where you wish the programming operation to start Defaults to 0 DEVICE END ADDRESS Enter the last address of the device you need programming Defaults to the device end address BUFFER START ADDRESS Enter the address of the first byte in the buffer from where you want to start programming Default is 0 BUFFER INCREMENT Allows you to program every byte every second byte every 4th byte or every 8th byte Default is Every Byte To accept the address selections or defaults press lt F10 gt The programmer will first check the device selection and position then perform a blank check and then proceed with programming While a device is being programmed a message will be displayed in the centre of the screen showing the address which has been reached Following programming an automatic verify will be conducted once completed a programming status report will display the status of each socket 6 5 2 Single key programming If you need to program more than one device in exactly the same way simply press lt F10 gt to repeat the process You are given the option to change a
43. p data io com dataio chipwriter Click the Programmer Device Support image or go to Technical Information and then ChipWriter Gang software e Once you have reached the ChipWriter Gang Library select the correct file and download the ChipWriter Gang compressed file e The ChipWriter Gang file comes in a self extracting file format Place the file on a floppy disk or temporary hard drive directory and then expand the file by running it The following files should be created File Name Description DIOGANG EXE INSTALL BAT Note It is recommended that the disk is labelled ChipWriter Gang and add the version number to avoid mismatched software version numbers if it becomes necessary to use the disk again e At the DOS prompt run the INSTALL BAT file and follow the instructions for installing in to the correct directory Warranty Conditions Data I O Corporation warrants this product against defects in materials and workmanship at the time of delivery and thereafter for a period of one 1 year The foregoing warranty and the manufacturers warranties if any are in lieu of all other warranties expressed implied or arising under law including but not limited to the implied warranties of merchantability and fitness for a particular purpose Data I O maintains customer service offices throughout the world each staffed with factory trained technicians to provide prompt quality service For warranty service contact your distri
44. r of times to repeat Each repeat is prompted at R C the R C parameters of the e command must be specified gives this help screen N B the environment variable CWGANG must point to the CWGANG directory 8 2 Batch software utilities TEXT Usage text message row col fg bg message is the text to display possibly enclosed in double quotes row col isthe position on the screen fg is the foreground colour of the text bg is the background colour of the text BOX Usage box col trow lcol brow rcol Default box is the whole screen col is the colour of the box trow 1col is the position of the top left corner of the box on the screen 0 0 to max of 22 77 brow rcol is the position of the bottom right corner of the box on the screen trow 2 lcol 2 to max of 24 79 ANSTIESC Usage ansiesc message message where message is ordinary text with the special escape code sequences Se esc code Ox1b Sf formfeed char for use with redirection to printer Ss space Sn carriage ENTER and newline Sd current directory xHH char HH HEX For example ansiesc e 0m Current Directory is e 1 5 7 33 45m d e 0m See DOS Manual for a list of ANSI ESC CODES including key redefinition s BEEP Usage beep ifregql durationl ifreg2 duration2 Makes a beep Frequency is inversely proportional to ifreq For example beep 400 8 500 8 400 8 500 8 400 8 500 8
45. rammer socket Please note that some devices CANNOT be read either because the chip type itself is designed not to be read for security purposes or because the on chip security features have been enabled when programming Before reading EPROM s ensure that the buffer size is set large enough to contain the data see section 6 2 1 on setting the buffer size NOTE To read the contents or part of the contents of a device select PROCESS READ The programmer software then quickly accesses the library file for the programming algorithm required You are then required to select the socket you wish to read from 0 7 or the Master socket A dialogue box then appears requesting Device Start and End address and Buffer start address EVICE START ADDRESS nter the first address from which you wish to start reading data from the device Default 0 EVICE END ADDRESS nter the last address from which you wish to read data from the device Defaults to the highest address available for the selected device BUFFER START BYTE ADDRESS Enter the buffer address where you wish to begin reading the data into Default 0 BUFFER INCREMENT Default Every byte Press lt F10 gt to accept the options displayed and the device will then be read The contents of the device will then be visible in the main data buffer and a checksum will be displayed D E D E
46. rifying the device type 6 4 4 Checking if a device is blank 6 5 Programming and erasing devices 6 5 1 Programming a device 6 5 2 Single key programming 6 5 3 Programming in Gang mode 6 5 4 Programming in Set mode 6 5 5 Erasing devices 6 6 Adding user defined devices Stand Alone Mode 7 1 Setting up the internal EEPROM 7 2 Setting up a Master configuration EPROM 7 3 Operating in stand alone mode 7 3 1 Programming in stand alone mode 7 3 3 Verifying in stand alone mode 7 4 LED Codes 7 4 1 LED status 7 4 2 Power up codes Batch Software 8 1 Batch software commands 8 2 Batch software utilities 8 3 Batch software error levels 8 4 Batch software examples APPENDICES Appendix A Shorthand Keystrokes Appendix B Menu Options Appendix C Technical Support 18 18 19 19 21 23 23 24 24 24 24 26 26 26 27 27 27 33 34 37 1 Introduction Congratulations on choosing a Data I O programmer We are sure that you will find the programmer software very easy to use and full of features to support all of your device programming requirements whether you are using it for development prototyping or production With your new programmer you will be able to Read data from programmed devices Load data in from disk Edit data Program a device Verify the contents of a device SSSss There are many other features of your programmer that will allow you to achieve the results you need This manual explains th
47. that frequently used files are saved in binary mode to save disk space and reduce loading time Use FILE SAVE AS This saves a user defined address range from the data memory area in any of the following formats RAW BINARY ASCII SPACE HEX ASCII OCTAL HEX MOTOROLA S2 format HEX INTEL To save any modifications to the currently loaded file simply select FILE SAVE 6 3 Using the editing facilities As well as loading from disk or reading a pre programmed device data to be programmed can be entered directly into the buffer from the keyboard In addition files can be amended using the DATA menu options 6 3 1 Entering EDIT mode To edit the contents of the data buffer select DATA EDIT This allows you to type in HEX or OCTAL code or ASCII characters Once EDIT is selected the cursor will move to the HEX display in the buffer window Use the lt TAB gt key to switch between HEX and ASCII In HEX mode only keys 0 9 and A F are allowed In OCTAL mode only keys 0 to 7 are allowed The cursor keys can be used to move around the buffer 6 3 2 Viewing without making changes If you wish to view the buffer contents beyond the first screen without danger of making unintentional changes to the data use DATA VIEW This allows you to view the data contents as HEX or OCTAL code or ASCII characters Once VIEW is selected the cursor wil
48. the buffer Press lt F10 gt to accept the default Select the device you are copying to if it is different see 2 Place the copy device s into the eight copy sockets only The MASTER socket is Read only Select PROC Appropriate programmed ESS PROGRAM Press lt F 10 gt to accept the default addresses messages will be displayed at the end of programming showing which devices have been correctly which sockets are empty etc TUTORIAL 2 Programming an EPROM from a file on disk l gt ON DMA Select FIL Specify the path and filename where your data is located Select the file format used HEX auto recognition will detect any of the HEX formats available Press lt F 10 gt to accept the default settings and load the data A checksum will be displayed on the screen Place the copy device s into the eight copy sockets only The MASTER socket is Read only Type CWGANG lt ENTER gt 2 Select the device you are wanting to program using DEVICE MANUFACTURER Select the manufacturer and press lt E NTER gt You will then be given a list of different types of devices Select the type and press lt ENTER gt You will then be prompted for the device name Choose the correct device name from the menu you are given and press lt ENTER gt to accept The details of the device you have chosen will now be displayed at the bottom of th
49. the cable should connect to the PC The cable will only fit the DB25 Parrallel port Tighten the holding screws thus ensuring that the cable will not cause programming problems STEP 2 Connect the power supply provided to the programmer and plug into any standard electrical outlet USE ONLY THE POWER SUPPLY ADAPTOR PROVIDED Replacements and adapters for different countries 240V 220V 100V 120V can be supplied by Data I O or their distributors STEP 3 Switch on the PC STEP 4 Run the DETECT program 3 3 Running the DETECT program The ChipWriter has been supplied with selftesting software which can check that the programmer has been installed correctly Before using the programmer for the first time or whenever moving it to a new PC run the DETECT program This has two purposes It confirms which parallel port is being used by the programmer It checks the programmer hardware WARNING Always ensure that there are no devices in the programmer before running Detect as leaving a device in the socket could damage the chip and give false results To run the program connect the programmer to the PC and mains supply remove any devices and type DETECT lt ENTER gt at the DOS prompt The DETECT will report the programmer s firmware version number and run a communications test It will then run through a series of memory checks and will report any faults found The program will report which port t
50. ttom pins next to the ZIF socket handle Devices inserted in any of the eight COPY sockets should be located at the bottom of the ZIF socket with the bottom pins furthest away from the ZIF socket handle Master Socket Copy Socket 1 32 1 28 1 24 1 20 1 16 1 8 Figure 4 1 Device Location If you are using a socket adapter please see the instructions with the adapter for how to place the device in the socket 4 2 Quickstart tutorials TUTORIAL 1 Programming an EPROM from a master device 1 Nn OoN Type CWGANG lt ENTER gt 2 Select the device you are using as a master using DEVICE MANUFACTURER Select the manufacturer and press lt ENTE R gt You will then be given a list of different types of devices Select the type and press you are give lt ENTER gt You will then be prompted for the device name Choose the correct device name from the menu n and press lt ENTER gt to accept The details of the device you have chosen will now be displayed at the bottom of the screen Ensure that the data memory buffer size is large enough to hold the data to be read from the master device You can change the buffer size using DATA BUFFER SIZE See section 6 2 1 for more information Insert the master device into any of the sockets of the programmer Select PROCE addresses SS READ to read the contents of the chip into
51. ufficiently see section 5 10 for information on installing EMS 6 2 2 Opening A file Select FILE OPEN This then displays a number of different options FILE NAME Enter the required filename FILE TYPE Select the required file format see section 6 2 3 FILE WINDOW LOW ADDRESS Enter the required file start address Default 0 FILE WINDOW HIGH ADDRESS Enter the required file end address Default FFFFFFFF FILE INCREMENT Select from Every Byte Every 2nd Byte etc up to Every 8th Byte BUFFER START ADDRESS Enter the required address Default 0 Pressing lt F 10 gt accepts the parameters and opens the selected file displaying the checksum when loaded See 6 2 5 6 2 3 File format The file type can be selected by pressing lt ENTER gt to see the options available Choose from RAW BINARY ASCII SPACE HEX ASCII OCTAL HEX AUTO RECOGNITION HEX MOTOROLA S1 S2 OR S3 RECORDS HEX INTEL MCS86 HEX TECTRONIX HEX EXTENDED TECTRONIX HEX TI TAG Choosing HEX AUTO RECOGNITION is generally the easiest way of loading a HEX formatted file However some linkers put additional headers at the start of the HEX file which can confuse the loader
52. urer s data sheet Speed and package indicators are only required when they affect programming algorithms 6 1 4 Low Voltage devices Low voltage devices are selected exactly as other devices In the device information in the bottom window you will notice that the Vcc voltages during program and verify VccP amp VccV respectively will be a combination of 5V and or 3 3V As most programmers are still unable to provide 3 3V circuits manufacturers still allow the devices to be programmed at 5V The ChipWriter programmers can not only verify a low voltage device at its nominal operating voltage they can also program with voltages down as low as 3 3V as well giving much greater flexibility 6 2 Opening data files Files can be loaded from disk into the data buffer and saved to disk after editing using the OPEN and SAVE options in the FILE menu See section 6 2 8 for more details on saving files 6 2 1 Setting the data memory buffer size It is necessary to ensure that the data memory area has been set to a size large enough to accept the contents of the file to be loaded Do this using DATA BUFFER SIZE Enter the required size in Kbytes The maximum buffer size available is determined by the available memory of the PC The programmer software uses approximately 150K plus the chosen buffer size The EMS software will use expanded memory for the buffer before using conventional DOS memory If the buffer cannot be increased s
53. used if it was desired to set up the programmer for more than one type of EPROM without having to go back to the PC In this case two EPROM s are needed A 27C512 for configuration information and a DATA MASTER EPROM for holding the user data The DATA MASTER will be the same type as that to be programmed 7 1 Setting up the internal EEPROM Select the device you are wanting to program from the DEVICE menu as described in section 6 1 From the MODE menu select the option SET UP INTERNAL EEPROM The programmer is now configured for the selected device A power on code is displayed see section 7 4 7 2 Setting up a Master configuration EPROM Ensure that the device to be used as the configuration EPROM is a standard 27C512 device Select the device you are wanting to program from the DEVICE menu as described in section 6 1 Use DATA FILL to ensure the buffer is filled with FF From the MODE menu select the option SET UP MASTER EPROM The on screen memory area now contains the required programming information for the selected device type Now select the 27C512 device being used for the CONFIGURATION master and program in the same way as described in 6 5 Only sockets 0 to 7 can be used for programming as the Master socket is read only 7 3 Operating in stand alone mode Once the configuration is complete switch off the programmer If you are using a Configuration E
54. when using this option Hence the other options ASCII SPACE HEX embodies the formats of ASCII space HEX ASCII HEX etc The software assumes that the file consists of HEX digits separated by non HEX characters Checksum information is not looked for and no separators are needed e g If a file consisted of A BCD EF this would appear as Address 0 1 2 3 Data 0A BC OD EF 6 2 4 Handling large files and devices In order to facilitate the programming of memory devices and the loading of files whose size is greater than the maximum buffer size the FILE OPEN command ALT O has the following parameters FILE WINDOW LOW ADDRESS FWLA FILE WINDOW HIGH ADDRESS FWHA FILE INCREMENT FINC BUFFER START ADDRESS BADD A byte is ONLY loaded into the buffer if its FILE ADDRESS is inside the window limits defined by the above inclusive range Data at FWLA is loaded into the buffer at BUFFER START ADDRESS The FILE NCREMENT works within this window See Figure 6 1 below BADD FWLA BADD 1 FWLA FINC BADD FWHA FWLA FINC FWHA Figure 6 1 Handling Large Files If you have file loading problems check the above parameters Normally FWLA 0 and FWHA FFFFFFFF i e the whole file is to be loaded O
Download Pdf Manuals
Related Search
Related Contents
User`s manual Agilent 1260 Infinity Preparative Pump 取扱説明書 - ご家庭のお客さま/大阪ガス User Manual KOHLER K-855-R-0 Installation Guide Samsung RS803GHMC7T Hướng dẫn sử dụng Can be modified by macros UNIVERSAL - Rack Attack pdf, 756 KB - Ernst Schweizer AG, Metallbau User Guide and Important Warranty Information Gold FSB Copyright © All rights reserved.