1.  North   facing wall  The sending range is 80ft   obstacles such as walls  concrete  and large  metal objects will reduce the range  Place  both units in their desired location before  permanently mounting     A  REMOTE TEMPERATURE   SENSOR   1  Remove the mounting bracket from  the remote temperature sensor   2  Mount using either screws or  adhesive tape    3  Reattach the remote temperature  sensor to the mounting bracket     B  THE TEMPERATURE STATION  1  The indoor temperature station comes  with the table stand already mounted   If you wish to use the table stand  all    17    that is required is to place the indoor  temperature station in an appropriate  location    2  To wall mount  remove the table  stand  To do this  pull down on the  stand from the rear and rotate forward   a  Fix a screw  not included  into the   desired wall  and place the indoor  temperature station onto the screw  using the hanging hole on the  backside  Gently pull the indoor  temperature station down to lock the  screw into place     18    TROUBLESHOOTING   NOTE  For problems not solved  please  contact La Crosse Technology via e mail or  phone  or visit our website   www lacrossetechnology com    Problem  The LCD is faint  Solution  Replace batteries    Problem  No outdoor temperature is  displayed    Solution    1  Remove all batteries  reinsert into remote  temperature sensor first  and then into the  indoor temperature station    2  Place remote temperature sensor closer to  the indoor te
2.  SET CH    button  once     2  Degree Fahrenheit will now show     a     To change between  Fahrenheit and Celsius   press and release the     MIN MAX    button   When you have your  choice shown on the  display press and release  the    SET CH    button  once     3  An hour will now be flashing     a     Press and release the     MIN MAX    button until  the correct hour is shown     Note  When in the 12h mode  there is    PM    displayed under    the word TIME when in the   PM hours  During the AM   hours this area will be blank    b  When the correct hour is  shown  press and release  the    SET CH    button  once     4  A minute will now be flashing    a  Press and release the     MIN MAX    button until  the correct minutes are  displayed     Press and release the    SET CH     button once more and you are done     DETAILED SETUP GUIDE    I  BATTERY INSTALLATION    A  REMOTE TEMPERATURE  SENSOR       1  Remove the mounting bracket    2  Remove battery cover   3  Observing the correct polarity  install  2 AA batteries   make sure they do not  spring free  or start up problems may  occur  Replace cover     B  INDOOR TEMPERATURE  STATION  Note  After the batteries are installed  DO  NOT press any buttons  This may interfere  with the signals  causing temperatures to  register incorrectly     1  Remove the battery cover on the  backside   2  Observing   the correct    polarity   install 2 AAA  batteries     3  Replace  battery cover   4  Wait 15  minutes p A  before      pre
3.  owner of the product to a USA  address only     Your La Crosse Technology  Ltd warranty covers all  defects in material and workmanship with the  following specified exceptions   1  damage caused  by accident  unreasonable use or neglect  including  the lack of reasonable and necessary maintenance     2  damage occurring during shipment  claims must    24    be presented to the carrier    3  damage to  or  deterioration of  any accessory or decorative  surface   4  damage resulting from failure to follow  instructions contained in your owner   s manual   5   damage resulting from the performance of repairs or  alterations by someone other than an authorized La  Crosse Technology  Ltd authorized service center    6  units used for other than home use  7   applications and uses that this product was not  intended or  8  the products inability to receive a  signal due to any source of interference   This  warranty covers only actual defects within the  product itself  and does not cover the cost of  installation or removal from a fixed installation   normal set up or adjustments  claims based on  misrepresentation by the seller or performance  variations resulting from installation related  circumstances     LA CROSSE TECHNOLOGY  LTD WILL NOT  ASSUME LIABILITY FOR INCIDENTAL   CONSEQUENTIAL  PUNITIVE  OR OTHER  SIMILAR DAMAGES ASSOCIATED WITH THE  OPERATION OR MALFUNCTION OF THIS  PRODUCT  THIS PRODUCT IS NOT TO BE USED  FOR MEDICAL PURPOSES OR FOR PUBLIC  INFORMATION  THIS PRO
4. BUTTONS FOR 15  MINUTES     In this time the indoor temperature  station and remote temperature sensor  will start to talk to each other and the  display will show both the indoor  temperature and an outdoor temperature   If the indoor temperature station does  not display both temperatures after the  10 minutes please retry the set up as  stated above  After both indoor and  outdoor temperatures are displayed for  15 minutes you can place your remote  temperature sensor outdoors and set  your time     The remote temperature sensor should  be placed in a dry  shaded area  The  remote temperature sensor has a range  of 80 feet  Any walls that the signal  will have to pass through will reduce  distance  An outdoor wall or window  will have up to 20 feet of resistance and  an interior wall will have up to 10 feet    of resistance  Your distance plus  resistance should not exceed 80 ft  in a  straight line    NOTE  Fog and mist will not harm  your remote temperature sensor but  direct rain must be avoided     To complete the set up of your indoor  temperature station after the 15 minutes  have passed please follow the steps  below     1  Press and hold the    SET CH     button for 5 seconds   Note  A    12h    or    24h    will appear  to the left of the time      12h    for  AM PM     24h    for military time    a  To change between    12h     and    24h    press and  release the    MIN MAX     button     When you have your  choice shown on the  display press and release  the   
5. DUCT IS NOT A TOY   KEEP OUT OF CHILDREN   S REACH     This warranty gives you specific legal rights  You  may also have other rights specific to your State   Some States do no allow the exclusion of    25    consequential or incidental damages therefore the  above exclusion of limitation may not apply to you     For warranty work  technical support  or information  contact     La Crosse Technology  2809 Losey Blvd  S   La Crosse  WI 54601  Phone  608 782 1610   Fax  608 796 1020    e mail   support lacrossetechnology com   warranty work        sales lacrossetechnology com    information on other products   web    www lacrossetechnology com       FCC DISCLAIMER    This device complies with part 15 of the FCC rules   Operation is subject to the following two conditions   1   this device may not cause harmful interference  and  2   this device must accept any interference received   including interference that may cause undesired  operation     26    Freq  433 92 MHz  La Crosse Technology  Made in China  WS 9117U    FCC ID  OMO 01RX  Receiver    OMO 01TX  sensor     THIS DEVICE COMPLIES WITH PART 15 OF  THE FCC RULES  OPERATION IS SUBJECT TO  THE FOLLOWING TWO CONDITIONS     1  THIS DEVICE MAY NOT CAUSE HARMFUL  INTERFERENCE  AND   2  THIS DEVICE MUST ACCEPT INTERFERENCE  RECEIVED  INCLUDING INTERFERENCE THAT  MAY CAUSE UNDESIRED OPERATION     27    
6. North America and only to the original  purchaser of this product  To receive warranty  service  the purchaser must contact La Crosse  Technology  Ltd for problem determination and  service procedures  Warranty service can only be  performed by a La Crosse Technology  Ltd  authorized service center  The original dated bill of  sale must be presented upon request as proof of    23    purchase to La Crosse Technology  Ltd or La  Crosse Technology  Ltd   s authorized service center     La Crosse Technology  Ltd will repair or replace this  product  at our option and at no charge as stipulated  herein  with new or reconditioned parts or products if  found to be defective during the limited warranty  period specified above  All replaced parts and  products become the property of La Crosse  Technology  Ltd and must be returned to La Crosse  Technology  Ltd  Replacement parts and products  assume the remaining original warranty  or ninety   90  days  whichever is longer  La Crosse  Technology  Ltd will pay all expenses for labor and  materials for all repairs covered by this warranty  If  necessary repairs are not covered by this warranty   or if a product is examined which is not in need or  repair  you will be charged for the repairs or  examination  The owner must pay any shipping  charges incurred in getting your La Crosse  Technology  Ltd product to a La Crosse Technology   Ltd authorized service center  La Crosse  Technology  Ltd will pay ground return shipping  charges to the
7. WS 9117U  Wireless 433 MHz  Temperature Station    Instruction Manual                               LA CROSSE technology tools  TECHNOLOGY for home  amp  office    TABLE OF CONTENTS  Topic  Inventory of Contents  Quick Setup  Detailed Setup Guide an  Battery Installation  Setting the Time  Selecting Units of  Measurement    8  Features  3  1    Resetting Minimum and 13 14  Maximum Temperatures    Minimum and Maximum   1  Temperatures    Additional remote 14 16  temperature sensors   optional     Mounting  Troubleshooting  Maintenance and Care  Specifications    Warranty Information 24 28       INVENTORY OF CONTENTS    1  The indoor temperature station  Figure  1    2  The remote temperature sensor  TX6U   and mounting bracket   Figure 2    3  3 each  1 2    Philips screws    4  One strip of double sided adhesive tape    5  Instruction Manual and Warranty Card   Figure 1 Figure 2   ADDITIONAL EQUIPMENT    not included    1  1 Philips screwdriver    2  2 Fresh AAA 1 5V batteries    3  2 Fresh AA 1 5V batteries     QUICK SETUP    Hint  Use good quality Alkaline  Batteries and avoid rechargeable  batteries     1  Have the indoor  temperature station and  remote temperature sensor  3 to 5 feet apart    2  Batteries should be out of  both units for 10 minutes    3  Place the batteries into the  remote temperature  sensor first then into the  indoor temperature station     All remote temperature sensors must be  started before the indoor temperature  station    4  DO NOT PRESS ANY  
8. ents or  scouring agents  they may mark the  displays and casings    e Do not submerge in water    e Do not subject the units to unnecessary  heat or cold by placing them in the  oven or freezer    e Opening the casings invalidates the  warranty  Do not try to repair the unit   Contact La Crosse Technology for  repairs     21    SPECIFICATIONS  Transmitting 433MHz  Frequency  Measuring Temperatures  Indoor 32  F to 140  F with 0 2  F  Temperature resolution    Station  Indoor  0  C to 69 0  C with  0 1  C resolution    21 8   F to 156 2  F with  0 2  F resolution     29 9  C to 69 0  C with  0 1  C resolution       1  F_  4    5  C   Transmitting Maximum 80 feet  25m   range open space  Temperature check   Indoor Every 10 seconds  Outdoor Two times in 10 minutes  Batteries    Alkaline recommended   Remote 2x AA  1 5V  Temperature  Sensor  Indoor                          Indoor  Temperature  Station  Outdoor         Temp accuracy                2 x AAA  1 5V    22    Temperature  Station    Dimensions   H x W x D    Indoor 5x 2 25 x lin  Temperature  excluding table stand   Station  125 x 58 x 23 mm   Remote 5x 15x lin    Temperature  128 x 40 x 23 mm   Sensor    Battery life Approximately 1 year       WARRANTY INFORMATION    La Crosse Technology  Ltd provides a 1 year limited  warranty on this product against manufacturing  defects in materials and workmanship     This limited warranty begins on the original date of  purchase  is valid only on products purchased and  used in 
9. is not done correctly and if   the total time for set up exceeds 6   minutes    2  It is necessary to remove the batteries  from all units currently in operation    3  Remove the battery covers to all  remote temperature sensor units    4  Place all remote temperature sensor  units in a numeric sequential order    5  In sequential order  install batteries   follow the same battery installation  procedures seen in section    I    of the  Detailed Set Up Guide     6  Install batteries into the indoor  temperature station    7  Follow the Detailed Set Up Guide for  programming and operating  instructions     15    D  VIEWING AND OPERATING  WITH MULTIPLE REMOTE  TEMPERATURE SENSOR UNITS  1  To view the temperature of a different   remote temperature sensor unit  press  and release the    SET CH    button  A  shift from one    boxed    number to the  next should be observed in the  OUTDOOR LCD    2  To view the Minimum Maximum  temperature  first select from which  remote temperature sensor to read data   indicated by the    boxed    number    Pressing and releasing the     MIN MAX    button will toggle  through the minimum and maximum  indoor temperature  and the minimum  and maximum outdoor temperature    3  To reset the Minimum Maximum  readings  press and hold the     MIN MAX    button for four seconds     16    V  MOUNTING  Note  To achieve a true temperature  reading  avoid mounting in direct sunlight   We recommend that you mount the remote  temperature sensor on an outside
10. mperature station    3  Be sure all batteries are fresh    4  Place remote temperature sensor and  indoor temperature station in position so  the straight line signal is not passing  through more than two or three walls     19    Problem  Temperatures do not match if  units are placed next to each other   Solution  Each temperature sensor is  manufactured to be accurate to within 1  degree plus or minus and under normal  conditions  so two temperature sensors could  be as much as 2 degrees different  However   the difference can be exaggerated further  because the temperature sensors are  designed for different working  environments  The indoor sensor is less  responsive to ambient air currents because of  the shielding effect of the display s case  In  addition  the case can act as a heat sink to  absorb and store heat from external sources   i e  handling of the case or radiant heat   In  addition  the much greater range of the  outdoor temperature sensor requires a  different calibration curve than the indoor  range  Error is usually greater at the extreme  ends of a range  making it harder to compare  different ranges with different curves  Under  non laboratory conditions  it is difficult to  compensate for the above factors and obtain  an accurate comparison     20    MAINTENANCE AND CARE  INSTRUCTIONS    e Extreme temperatures  vibration  and  shock should be avoided to prevent  damage to the units    e Clean displays and units with a soft   damp cloth  Do not use solv
11. ssing any buttons                                                              i             10    5  The indoor temperature station should    now show              in the er   TIME LCD  and EH   temperatures in the Jk   INDOOR and 10   OUTDOOR LCD   s  i 2  II  TIME    A  SETTING THE TIME  1  Press and hold  the    SET CH     button for 5  second     12h       will appear in  the TIME LCD    2  Press and release the    MIN MAX     button to select either 12h time   am pm  or 24h time   3  Press and release the    SET CH     button 2 times  the hour will flash in  the upper left corner    4  Press and release the    MIN MAX     button to set the hours       11    5  Press and release the    SET CH     button to move to the minute setting   6  Press and release the    MIN MAX     button to set the minutes    7  Press and release the    SET CH     button to activate the clock     Note  When in 12h mode  there is only a     PM    display  which appears under    TIME      If there is no display here it is AM  Make  sure you set the time accordingly     III  UNITS OF TEMPERATURE  MEASURE    A  SELECTING UNITS OF  MEASUREMENT  1  Press and hold the    SET CH    button  for 5 second until    12h    or    24h     appears in the TIME LCD   2  Press and release the    SET CH       button again       F    will appear in the  TIME LCD     12    3  Press and release the    MIN MAX     button to shift between   F and   C    4  Press and release the    SET CH     button twice to activate se
12. ttings     IV  FEATURES    A  MINIMUM AND MAXIMUM   TEMPERATURES   1  Press and release the    MIN MAX     button     MIN    appears in the  temperature LCD   s and the recorded  minimum temperatures are displayed    2  Press and release the    MIN MAX     button to toggle to the maximum  temperatures  The time of occurrence  of the value for outdoor temperature  will also flash     B  RESETTING THE MINIMUM AND  MAXIMUM TEMPERATURES  1  To reset both the minimum and  maximum temperatures   press and  hold the    RESET      button for 4    13    seconds     C  ADDING ADDITIONAL  REMOTE TEMPERATURE  SENSORS  OPTIONAL    1  The WS 9117U is able to receive  signals from 3 different remote  temperature sensors  Following are  some brief instructions for the basic  set up of remote temperature sensor  units with the WS 9117U  These extra  sensors can be purchased through the  same dealer as this unit  or by  contacting La Crosse Technology  directly  A TX6 will monitor  temperature only  a TX3U will  monitor temperature and display the  temperature on its LCD  and the  TX3UP will monitor the temperature  via a probe for use in pools  spas  etc    Note  When setting up multiple units it   is important to remove the batteries   from all existing units in operation   then to insert batteries first into all the    14    remote temperature sensor units  and in   numeric sequence  Second  install   batteries into the indoor temperature  station  Transmission problems will  arise if this 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Avocent EMS1000R    Configure the stick reader  Akasa Cypher  BEAT-MV/BEAT-2  Montage- und Wartungsanleitung  Installateur  Electrolux B4140-1 User's Manual  Serie FKS-EU    Copyright © All rights reserved. 
   Failed to retrieve file